Air Receiver Volume:
V = t*(qout -qin)*Pa / (P1-P2)
where
V = Volume of the receiver tank, ft3
t = time for the receiver to charge or discharge, min
qout = air flow out of the recieiver (surge flow to consumer), cfm
qin = air flow into the receiver from compressor, cfm
Pa = Atmospheric Pressure (14.7 psia)
P1 = Upper or Maximum operating pressure, psia or psig (P 1 and P 2 should both be either in absolute or gauge units)
P2 = Lower or Minimum operating pressure, psia or psig (P1 and P2 should both be either in absolute or gauge units)
Example:
Inputs:
t = 5 min
qout = 350 cfm
qin = 250 cfm
Pa = 14.7 psia
P1 = 100 psig
P2 = 60 psig
Calculation:
V = 183.75 ft3
1374.546 U.S. gallons
5.20 m3
Prepared by: Ankur Srivastava
Chemical Engineer
e-mail: [email protected]
The output from a compressor is 250 cfm. There is a surge flow requirement of 350 cfm for a period of 5 minutes. The upper
or maximum operating pressure is 100 psig and the lower or minimum operating pressure is 60 psig. What size of receiver
is required to cater to the surge volume rate demand and surge time?
Disclaimer : The information and methods included within this spreadsheet are presented for air receiver sizing. It
is intended to be used by technically skilled persons at their own discretion. I do not warrant the suitability or
accuracy of these methods.
Compressed Air Receiver Volume:
Rule of Thumb for compressed air receiver sizing is 1 U.S. gallon capacity for every ACFM compressor flow
Example Problem:
Calculations:
Volume at actual pressure and temperature is calculated by ideal gas law
Now by ideal gas law
P1*V1 / T1 = P2*V2 / T2
Where the subscript 1 describes the standard conditions of pressure and temperature and subscript 2 describes the actual conditions of temperature and pressure
Standard Pressure = 14.7 psia
Standard Temperature = 68 °F
Flow Rate @std pr.& temp. = 300 scfm
Discharge Pressure = 100 psig
Discharge Temperature = 40 °C
Calculate value of V 2
P1 = 14.7 psia
V1 = 300 scfm
T1 = 528 °R (68+460)
P2 = 114.7 psia (100+14.7)
T2 = 564 °R (1.8*(40+273.15))
V2 = (T2/T1)*(P1/P2)*V1
41.05 acfm
Calculate Compressed Air Receiver Volume
Receiver Vol. per ACFM = 1 gallon
Receiver Vol. for example = 41.05 gallon
5.49 ft3
0.16 m3
Prepared by: Ankur Srivastava
Chemical Engineer
e-mail: [email protected]
If the compressor volume flow is described at standard conditions (14.7 psia, 68°F), it will be needed to convert it to actual volume flow (e.g. compressor
discharge) at actual conditions of pressure and temperature. As an example this means converting volume flow in SCFM (Sm3/h) to ACFM (m
3/h)
The volume flow of a compressor is described in standard conditions as 300 scfm. The compressor discharge conditions are
given as follows: a) Discharge pressure: 100 psig, b) discharge temperature: 40°C. Calculate the compressed air receiver
volume for the given discharge conditions.
Disclaimer : The information and methods included within this spreadsheet are presented for air receiver sizing. It is
intended to be used by technically skilled persons at their own discretion. I do not warrant the suitability or
accuracy of these methods.
Rule of Thumb for compressed air receiver sizing is 1 U.S. gallon capacity for every ACFM compressor flow
Where the subscript 1 describes the standard conditions of pressure and temperature and subscript 2 describes the actual conditions of temperature and pressure
If the compressor volume flow is described at standard conditions (14.7 psia, 68°F), it will be needed to convert it to actual volume flow (e.g. compressor
discharge) at actual conditions of pressure and temperature. As an example this means converting volume flow in SCFM (Sm3/h) to ACFM (m
3/h)
The volume flow of a compressor is described in standard conditions as 300 scfm. The compressor discharge conditions are
given as follows: a) Discharge pressure: 100 psig, b) discharge temperature: 40°C. Calculate the compressed air receiver
volume for the given discharge conditions.