1
Status of infrastructureStatus of infrastructure
MICE Video Conference, August 17, 2005
Yury Ivanyushenkov
Applied Science Division,Engineering and Instrumentation Department
RAL
2
• Magnetic shielding in the MICE hall
• MICE hall preparations
• Support system overview
• Spectrometer solenoid support
Scope
3
Magnetic shielding in the MICE hall
4
Magnetic field should not exceed 5 gauss in a public area (ISIS control room).
Magnetic modelling predicts that the 5 gauss line is outside the MICE hall – passive shielding may have to be used.
MICE fringe fields: Problem
Volume in blue: 1000 gauss field
Volume in orange: 5 gauss field
5
Fringe fields: Passive magnetic shielding
Flux lines from unshielded coils (MICE Stage 6)
Flux lines from shielded coils with a cylindrical, 10 mm thick steel shield, D=10m.
2d axi-symmetric model of iron shield
20 mm
r =4 m
Coil axis
6
Magnetic shielding: Thickness
00.00050.001
0.00150.002
0.00250.003
0.00350.004
0.00450.005
0.00550.006
0.00650.007
0.0075
4.5 4.7 4.9 5.1 5.3 5.5
Field radially at Z=0 (m)
Bm
od (
T)
No shielding
10mm
5mm
3mm
5 gauss
Field detail in the shield region for the different thickness of steel cylinder modelled.
7
Coil axis
20 mm8 m
8 m
20 m
3d rectangular model of iron shield8 m
3d rectangular model of iron shield top half only
Coil axis
20 mm4 m
20 m
3d rectangular model of iron shield extended to ground level
2d axi-symmetric model of iron shield
20 mm
r =4 m
Coil axis
MICE magnetic shield: Models
Coil axis
20 mm6 m
20 m2 m
8 m
By Jim Rochford
8
BH curve for iron as used in the models
0
5000
10000
15000
20000
25000
0 500 1000 1500 2000
H(Oe)
B(g
)
MICE magnetic shields: Iron
9
3d model of complete rectangular shield Bpeak=0.67T
MICE magnetic shield: Complete rectangular shield
5 gauss line
10
3d model of ½ a rectangular shield Bpeak=0.93T
5 gauss line
MICE magnetic shield: Half of a rectangular shield
11
3d model of a rectangular shield extending to floor Bpeak=0.82T
5 gauss line
MICE magnetic shield: Extended half of a rectangular shield
12
Peak field in shield for different models
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1
3950 3960 3970 3980 3990 4000 4010 4020 4030 4040 4050
distance along x at y=1 z=1375 (mm)
Bm
od (T
)
3d rectangular tube
3d 1/2 rectangular tube
3d rectangular tube extended to ground
2d cylindrical tube
MICE magnetic shield: Peak field in shield
13
Effect of the presence of the shield on the axis field
MICE Collaboration meeting @ Columbia, 14 June 2003
MICE magnetic shield: Effect on the axis field
-4
-3
-2
-1
0
1
2
3
4
5
6
0 1000 2000 3000 4000 5000 6000
Fiel
d (T
)
-4
-2
0
2
4
6
8
Diff
eren
ce (g
auss
)
With 20mm thick iron shieldNo shieldDifference (gauss)
14
Top Fx=0,Fy=-1470,Fz=0
1470N
150N
1330N
Z X
Y
MICE magnetic shield: Forces
Sides
Fx=(+/-)1330,
Fy=-150,
Fz=0
15
MICE magnetic shielding
2m
3.8m
5.6m 17m
6m
Revised 3D model:
Open ended rectangular box model20mm thick iron plate
+Two 150mm thick iron platesID 40mm OD 3.6m
16
MICE magnetic shielding
For 200Mev/c, beta 43cm - mode
Outer surface of Outer surface ofShield components ISIS injector wall Control room wall
Bmod (g) Bmod (g)Top+sides+detector 0.8 2.23
Top+sides 0.72 2.33Sides+detector 0.71 2.39
No shielding 1.78 12.5
200MeV/c beta 43cm
Fringe field on outer walls
17
• 2d and 3d models agree well
• Can effectively contain 5 gauss line within hall by using a 20mm thick rectangular shield.
• Initial calculations of the forces on the shield are small
• The field has a very small effect on the axis field
Next step:
- Create a realistic two-wall model of the shield based on the MICE layout (see next slide) and the latest version of MICE magnetic configuration;
- Check shielding efficiency ( wall thickness is a parameter).
MICE magnetic shield: Summary of modelling
18
MICE magnetic shielding layout
Magnetic shielding walls
19
Magnetic shielding walls
MICE magnetic shielding layout
20
Magnetic shielding in the MICE hall
Conclusion:
• Preliminary modelling suggests that passive shielding of MICE will work.
• Modelling needs to be finalized.
• Magnetic shielding design needs to be completed.
21
MICE hall preparations
22
MICE phase I initial
23
MICE phase I final
24
MICE hall preparations: To-do list
1. Floor levelling:• concrete plinth at the lower floor part of the building• fill up the cellar• floor extension frame over the trench
2. Beam line radiation shielding support over the trench.
3. Staircases modification:• the staircase on the ISIS linac side of the building • the staircase on the ISIS control room side
4. Holes in the roof and the north wall:• in the roof – for ventilation ducts• in the wall – for hydrogen vents
25
MICE hall preparations: To-do list (2)
5. Hydrogen system R&D area• hydrogen extract hood and vent lines• part of mezzanine floor• part of magnetic shielding wall
6. The rest of magnetic shielding walls.
7. Beam-line radiation shielding.
26
MICE hall preparations: Status and plans
• General layout is completed.
• Discussion with RAL civil engineers has started -> work will be done by the external company
• Programme of hall modification is being prepared
27
Support system overview
28
Support structure – Layout and sequences
29
Support structure - Required rail positions
MICE Stage IV MICE Stage V
Rail positions of downstream detector for Stages IV & V will overlap with final stage VI rail positions
30
Support structure – Rail and Force transfer concept
Y
XZ
Magnetic force
Traverse in X on rail system to give location to +/- 2mmJack from rail and position in x-y-z to survey targets on vacuum vesselShim to blocking plates to locate in x-y-z and react forces
Module
Jacks
Rollers
Rails
Floor Plate
Y support location
Shim
Beam Axis
Survey Target
31
Support structure – Super-module
Module to module joints to react forces in Z
CC/RF module with stiff support structure
32
Support structure – Rail-mounting concept
Platform moves on rails
Platform is jacked from the rails
33
Support structure – Force transfer concept - Y
Shimming to react vertical forces
34
Support structure – Force transfer concept - Z
Shimming to react axial (Z) forces
35
MICE rail system
Rails
36
Concrete floor
Support structure
Dia 650Aperture in ISIS wall
1684.2
160*
1524*
Height of the beam in the MICE hall
37
Module Weight, kg
AFC module 1700
RF module 4636
Radiation shield 310
Tracker module 6650(including 1200 kg of magnetic shield)
MICE support structure - Module weights
Table from Wing
Note: Table requires updating
Crane lifting capacity is 12 tonnes (two cranes joined) or 8 tonnes (one crane)
38
MICE support structure – Next steps
• Revise support structure requirements/specs for full MICE - include and analyze requirements of access to every module ( collect information from all technical supervisors)
Who is doing this ?
• Suggest support structure for Stage 2 (MICE phase 1) (is it different from the one for complete MICE ?)
• Discuss revised version of support structure at RAL meeting
39
Spectrometer solenoid support
40
Solenoid out the beam - position
Solenoid in the beam - position
Spectrometer solenoid positions
41
Spectrometer solenoid support: Next steps
• Revise support structure requirements - include and analyze requirements of access ( collect information from the technical supervisors) Who is doing this?
• Suggest support structure for spectrometer solenoid at RAL meeting
42
MICE module max height
Concrete aperture
Important: The max height from the bottom of the support frame to the topof a module should not exceed 3200 mm
Concertina door
Hinged door
Max horizontal opening 3200 mm
Max vertical opening 3360 mm