1
Acc
esso
ries
and
Sup
plie
s
3
HP
LC C
olum
ns
web: www.bonnaagela.com
Best ValueGuaranteed Product QualityInnovation to Benefit Customers
Bonna-AgelaTechnologiesBETTER SOLUTIONS FOR CHROMATOGRAPHY
Bonna-Agela Technologies — A Global Supplier for Chromatography Solutions
2014 Message From Bonna-Agela Technologies
As Bonna-Agela is poised to enter its seventh year with confidence and pride in its innovative separation, purification, and sample preparation products, we would like to thank everyone who has supported or contributed to Bonna-Agela Technologies in some way.
What a journey it has been, and Bonna-Agela has become one of the leading chromatography companies after several years' efforts.
Our manufacturing and R&D operation were certified in compliance with ISO 9001, ISO 14001 and passed many quality audits by customers and distributors, including VWR International.
Bonna-Agela remains dedicated to making a difference in R&D, manufacturing, service and applications. Bonna-Agela's HPLC products have acknowledged by USP-PQRI as a contributor of their column database, and Venusil C18 HPLC columns, for example, have been recommended by European Pharmacopoeia.
Bonna-Agela teams never stop pursuing new technologies to bridge the gap between conventional HPLC and new Ultra High Performance LC (UHPLC) systems. Bonna-Agela's sub-2 um Bonshell HPLC columns have been a best choice for applications in both areas, which deliver improved sensitivity and long-lasting lifetimes.
Bonna-Agela has engaged in a new business sector in developing and manufacturing LC hardware and systems for analytical and preparative applications along with our recognized consumables. Flexa MD LC system, one of the many products from this line, has been recommended by the well-known Nature magazine "Product Focus: chromatography"
As one of the core technologies at Bonna-Agela, production scale of specialty chromatography materials has advanced to a new level in tens of kilograms in a single batch with high batch-to-batch reproducibility. Selection from a variety of chromatography media has never been made more easier at Bonna-Agela for your applications.
Your satisfaction is Bonna-Agela's goal. It is an one-stop call to Bonna-Agela's service and applications department for your applications inquiry and service requirement. We would emphasize, however, on the challenging part of the business for better products, satisfied service and new development. Your continued support will be a key to our success and your satisfaction in the coming year
4
Acc
esso
ries
and
Sup
plie
s
Terms and Conditions
Acceptance and AvailabilityAll orders placed are subject to the agreement of Bonna-Agela Technologies Inc. The catalogue does not constitute an engagement of the company to sell all listed products. You are guaranteed to be notifi ed at the time of ordering if the ordereditems are in back-order or discontinued.
Price and PaymentThe prices are in effect at the time of printing. Bonna-Agela Technologies reserves the right to change the prices without notice, though we do our best to provide our customers with advance notice. The prices quoted at the time of ordering will be guaranteed. The general payment term is net 30 days, F.O.B., Newark, Delaware, USA. However we reserve the right to ask for prepayment if customers’ account information is not satisfactory. A 1.5% per month service charge will be added to delinquent accounts. If a purchase order is less than $1000.00, a $50.00 extra charge will be added to the invoice.
ChangesBonna-Agela Technologies reserves the right to change product specifi cations, quantities, designs or prices without prior notice and without liability for such changes.
Shipping PolicyThe standard shipping method is 2 day FedEx within the United States and Canada. We will try to accommodate requests for other shipping methods if they are available. All shipping and handling charges will be billed separately. Should you receive damaged goods, it is imperative that you notify us immediately and save all packing materials for inspection by the carrier.
ApplicationAll products in this catalog should be used for laboratory or manufacturing use only. They are not intended for direct medicinal or food use. Bonna-Agela Technologies assumes no liability for any misuse of the products.
ReturnsBonna-Agela Technologies tries to accommodate all requests for returns of unused goods. However,return of some items may be restricted by the original manufacturers. Please contact us for return authorization before returning any items. A restocking charge may be applied to certain products.
WarrantyAll Bonna-Agela Technologies products are warranted to be free of defects in materials and workmanship. They are not warranted for any other particular purpose. Bonna-Agela Technologies shall not under any circumstance be liable for any incidental, consequential or compensatory damage in conjunction with its products. The maximum liability shall not exceed the invoice price of the product.
PLEASE READ THESE TERMS BEFORE ORDERING. IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO CONTACT US AND OUR STAFF WILL BE GLAD TO ASSIST YOU.
How to Place Orders
Our offi ce is open from 9:00 am to 6:00 pm Eastern Standard Time, Monday through Friday.
To place an order or receive a quote, you may choose from the following contacts:
Bonna-Agela Technologies US2038A Telegraph Rd.Wilmington, DE 19808, USATel: (302) 438 8798Fax: (302) 636 9339E-mail: [email protected]
Bonna-Agela IndiaG#212, 2nd Floor, Sector-63, Noida, Uttar Pradesh Tel: 0120-4225466-71 Fax: 0120-4225465
Bonna-Agela China179 South Street, Teda West Zone, Tianjin 300462, ChinaTel: +86(22)25321032/7023 Fax: +86(22)25321033
Checks:Please make checks payable to:Bonna-Agela Technologies Inc. and send to: Bonna-Agela Technologies Inc.2038A Telegraph Road, Wilmington, DE 19808, USA
Wire Transfer:Please contact us by phone, fax or email for account information.
Credit Cards:Please include the card type and number, expiration date, and card holder name. Due to security concerns, please do not email the information. Please call or send a fax to provide your credit card information.
5
Acc
esso
ries
and
Sup
plie
s
Accessories and Supplies
ClarinertTM Filtration Products
Syringe Filters
Membrane Filters
96-Well Filtration Plates and Collection Plates
Glass Filtration System
Disposable Filtration Funnels with 10 μm Frits
Vials and Seals
Shell Vials and Seals
Inserts For 2 ml Short Thread Screw Vials
2 mL 12x32 mm Screw Neck Vials and Seals
ND11 12x32 mm Snap Ring Vials and Seals
ND11 2 mL 12x32 mm Crimp Neck Vials and Seals
Screw Neck Vials for Storage Purposes
Crimper for HS Vials
Headspace Vials and Seals
2 mL Vial Rack (Cat. No AR0002-1)
HPLC Accessories and Supplies
UV Lamps
Pipettes and Accessories
Disposable Syringe for HPLC Filtration
HPLC Fittings and Tubing
001
001
008
010
010
010
011
011
011
011
012
012
012
013
013
013
014
014
014
015
015
001
Acc
esso
ries
and
Sup
plie
s
ClarinertTM Filtration Products
■ High Quality
■ Cost saving■ Comprehensive■ Reliable partnership
■ Syringe Filters■ Membrane Filters■ 96-Well Filtration Plates and Collection Plates■ Glass Filtration System■ Disposable Filtration Funnels with 10 μm Frits
Important Features
– Bonna-Agela is an ISO 9001 certifi ed manufacturer; all of our products are guaranteed to meet our published specifi cations.– Reduce substantially the customers cost without sacrifi cing quality.– Comprehensive product lines; including some very unique products– Global OEM manufacturing partner
– All fi lters’s housing is made of high purity polypropylene– Female luer-lock inlets on all fi lters secure the fi t to syringes– All fi lters are designed for use in both direction– All fi lters are autoclavable– All products are certifi ed
Syringe Filters
■ Single Layer Filters: Single membrane, commonly used, highly cost-effective; newly developed Ф33 mm Syringe Filters, with pore sizes of 0.22 μm and 0.45 μm are in stock.■ Double Layer Filters: A prefi lter before the main membrane, which would avoid the damage to the soft main membrane from larger particles and clogging of the main membrane by colloidal particles, is good for the overall lifetime, process volume, and effi ciency.■ IC Syringe Filters: The Nylon membrane fi lter is specially developed for IC fi ltration and is manufactured with advanced technology, with micro-pores evenly distributed with extremely low ion residual, which can effectively fi lter the particulate impurities.■ Drying Filters: Syringe fi lters with PTFE membrane, embedded with MgSO4, to combine the drying function with fi ltration in one single step for organic samples. Simple, fast and convenient to use!■ Metal Remover: Syringe fi lters with PTFE membrane, embedded with metal scavenger resin to remove heavy metals from the organic samples at the same time of fi ltration, to eliminate the interference of the metal in subsequent tests, or to protect the HPLC columns from contamination. Simple, fast and effective!■ Organic Remover: Syringe fi lters with nylon membrane, embedded with polystyrene resin to remove hydrophobic organic interference from samples for ion-chromatography, HPLC, molecular biology testing, etc. Simple, convenient and reliable!■ Sterilized Filters: Filter the sample with biological activity or aseptic requirements; generally used as a fast, convenient, reliable sterilization and fi ltration tool in the lab. We supply many kinds of syringe fi lters, which can be used for fi ltration of 1mL to 300 mL sample solutions.
Type of Filters
002
Acc
esso
ries
and
Sup
plie
s
Specifi cations
Type Diameter(mm)
Pressurerating (bar)
Bubble Pointrating(bar)
Water speed(mL/min/cm2)
Air speed(L/min/cm2)
Filtration/Hold-up Volume
Effectivefi lter area(cm2)
Pore size(μm)
10 mL/<25 μL
100 mL/<100 μL
10 mL/<25 μL
100 mL/<100 μL
10 mL/<25 μL
100 mL/<100 μL
10 mL/<25 μL
100 mL/<100 μL
10 mL/<25 μL
100 mL/<100 μL
10 mL/<25 μL
100 mL/<100 μL
--------
162016205858--------
18601860257525751535153524602460--------
3.522.203.522.202.802.502.802.501.200.561.200.561.000.631.000.63
--------
775577557755775577557755
0.220.450.220.450.220.450.220.450.220.450.220.450.220.450.220.450.220.450.220.450.220.450.220.45
13
25
13
25
13
25
13
25
13
25
13
25
MCM
Nylon
PVDF
PTFE
PES
Reg.Cellulose
0.650.653.903.900.650.653.903.900.650.653.903.900.650.653.903.900.650.653.903.900.650.653.903.90
Selection Guide
Material Type Characteristics
MCM(Hydrophilic)
Nylon
PTFE(Hydrophobic)
PVDF(Hydrophilic,Hydrophobic)
PES(Hydrophilic)
Reg. Cellulose(Hydrophilic)
Remove the particle from aqueous; Can be high temperature sterilized. Low protein-binding.
Good fl exibility and chemical compatibility (avoid strong acid and strong organic solution).
Broad chemical compatibility (compatible to any common solvents). Low protein-binding; Can be high temp. sterilized repeatedly; Low extractable; For use with high aqueous solution, pre-wet the fi ltermembrane with MeOH, then rinse with DI water before fi tering samples.
Low extractable; Low protein-binding; Broad chemical compatibility (avoid strong basic solution); Hydrophobic: for use with organic solution;Hydrophilic: can be used with high aqueous solution without pre-wet steps.
Broad chemical compatibility;Apply to high-throughput, high effi cient fi ltration;Low protein-binding.
Low protein-binding;Better strength than MCM.
003
Acc
esso
ries
and
Sup
plie
s
The introduction of extra impurities (extractables) is undesired; we should minimize the extractables during sample preparation.Extractables are often the result of inappropriate choice of materials, improper operation of the device during the manufacturing process,or downstream particle shedding. Particular attention should be paid to potential impurities from the membrane and housing material.The membranes used in Bonna-Agela’s Clarinert Filters are extensively tested to determine their compatibility with various HPLC solvents.
Remarks: R (Resistant), LR (Limited Resistant), NR (Not Resistant)
Chemical Compatibility
Material MaterialMCM MCMR.C R.CNylon NylonPTEE PTEE
1-hexanolCH3COOH, 10 %acetoneacetonitrilefatty hydrocarbonammonia, 1 Maromatic hydrocarbonsbenzeneboric acidtetrachloromethanecarboxylic acidchloroacetic acidchloroformcyclohexanecyclohexanolaetherDMFDMSOalcohol=<98 %ethyl acetatechloroethylene
glycolformic acid, 25 %n-hexaneHCl, 25 %isopropanolmethanolnitrous acid, 25 %pentanephosphoric acid, 25 %phosphoric acid, 45 %KOH, 1Mmineral salt in waterNaOH, 1Mcellontetrahydrofurantolueneacetocaustin, 10 %methyl chloroformchlorylenexylene
RLRNRNRRRRRRLRRNRNRLRRLRNRNRRNRLR
RLRRNRRRLRRRLRNRRLRLRNRRNRLRLRR
RRRRRRRRRLRRNRNRLRRLRNRNRRNRLR
RRRRRRRRRLRLRRNRRRRNRRRR
R-RRRRN/ARLRNRNRNRRRRRRN/ARRR
R-RNRRLRNRRLRLRNRRNRLRRRLRLRLRR
RRRNRRRRRRRRRLRRRLRRRRRR
RRRRRRRRRRRRRRLRRRRRR
Instrument: Waters 600e Pump, 717 Auto-sampling, 2487UV Detector Column: Venusil ASB C18, 4.6×250 mm, 5 μm; Mobile Phase: Water: ACN= 22 : 78; Wave Length: 251 nm
Comparison of Clean Performance of Three Brands’ Filters
AU
0.000
0.005
0.010
0.015
1.93
52.
180
5.39
9 6.30
1
15.2
49
AU
0.000
0.005
0.010
0.015
1.38
8
2.37
7
5.40
7
15.3
11
AU
0.000
0.005
0.010
0.015
Minutes0.00 1.00 2.00 3.00 4.00 5.00 6.00 7.00 8.00 9.00 10.00 11.00 12.00 13.00 14.00 15.00 16.00
1.97
92.
307
2.90
7
3.36
0
3.78
2
4.56
4
5.40
2
8.48
1 9.27
9
9.66
49.
902
15.2
89
Agela ClarinertTM
Brand W
Brand X
004
Acc
esso
ries
and
Sup
plie
s
Ordering Information
★ Single Layer & Double Layer
Mixed Cellulose(Ccetate and Nnitrate) Syringe Filters
Nylon Syringe Filters
13 mm
25 mm
33 mm
13 mm with glass prefi lter
25 mm with glass prefi lter
33 mm with glass prefi lter
13 mm
25 mm
33 mm
13 mm with PP prefi lter
25 mm with PP prefi lter
33 mm with PP prefi lter
AS011320AS011345AS012520AS012545AS013320AS013345AS011320-GAS011345-GAS012520-GAS012545-GAS013320-GAS013345-G
AS021320AS021345AS022520AS022545AS023320AS023345AS021320-PAS021345-PAS022520-PAS022545-PAS023320-PAS023345-P
0.22 μm0.45 μm0.22 μm0.45 μm0.22 μm0.45 μm0.22 μm0.45 μm0.22 μm0.45 μm0.22 μm0.45 μm
0.22 μm0.45 μm0.22 μm0.45 μm0.22 μm0.45 μm0.22 μm0.45 μm0.22 μm0.45 μm0.22 μm0.45 μm
200200100100100100200200100100100100
200200100100100100200200100100100100
Membrane Type Pore Size Cat.No.Qty
Hydrophobic PVDF Syringe Filters13 mm
25 mm
33 mm
13 mm with PP prefi lter
25 mm with PP prefi lter
33 mm with PP prefi lter
AS031320AS031345AS032520AS032545AS033320AS033345AS031320-PAS031345-PAS032520-PAS032545-PAS033320-PAS033345-P
0.22 μm0.45 μm0.22 μm0.45 μm0.22 μm0.45 μm0.22 μm0.45 μm0.22 μm0.45 μm0.22 μm0.45 μm
200200100100100100200200100100100100
005
Acc
esso
ries
and
Sup
plie
s
Polyethersulfone (PES) Syringe Filters
Hydrophobic PTFE Syringe Filters
13 mm
25 mm
33 mm
13 mm with glass prefi lter
25 mm with glass prefi lter
33 mm with glass prefi lter
13 mm
25 mm
33 mm
13 mm with PP prefi lter
25 mm with PP prefi lter
33 mm with PP prefi lter
AS051320AS051345AS052520AS052545AS053320AS053345AS051320-GAS051345-GAS052520-GAS052545-GAS053320-GAS053345-G
AS041320AS041345AS041301AS042520AS042545AS042501AS042505AS043320AS043345AS043301AS041320-PAS041345-PAS042520-PAS042545-PAS042501-PAS042505-PAS043320-PAS043345-P
0.22 μm0.45 μm0.22 μm0.45 μm0.22 μm0.45 μm0.22 μm0.45 μm0.22 μm0.45 μm0.22 μm0.45 μm
0.22 μm0.45 μm1.00 μm0.22 μm0.45 μm1.00 μm5.00 μm0.22 μm0.45 μm1.00 μm0.22 μm0.45 μm0.22 μm0.45 μm1.00 μm5.00 μm0.22 μm0.45 μm
200200100100100100200200100100100100
200200200100100100100100100100200200100100100100100100
Membrane Type Pore Size Cat.No.Qty
Regenerated Cellulose (RC) Syringe Filters13 mm
25 mm
33 mm
13 mm with glass prefi lter
25 mm with glass prefi lter
33 mm with glass prefi lter
AS061320AS061345AS062520AS062545AS063320AS063345AS061320-GAS061345-GAS062520-GAS062545-GAS063320-GAS063345-G
0.22 μm0.45 μm0.22 μm0.45 μm0.22 μm0.45 μm0.22 μm0.45 μm0.22 μm0.45 μm0.22 μm0.45 μm
200200100100100100200200100100100100
006
Acc
esso
ries
and
Sup
plie
s
Hydrophilic PVDF Syringe Filters13 mm
25 mm
33 mm
13 mm with glass prefi lter
25 mm with glass prefi lter
33 mm with glass prefi lter
AS071320 AS071345 AS072520 AS072545 AS073320 AS073345 AS071320-GAS071345-GAS072520-GAS072545-GAS073320-GAS073345-G
0.22 μm0.45 μm0.22 μm0.45 μm0.22 μm0.45 μm0.22 μm0.45 μm0.22 μm0.45 μm0.22 μm0.45 μm
200200100100100100200200100100100100
Membrane Type Pore Size Cat.No.Qty
Glass Fiber Syringe Filters13 mm
25 mm
33 mm
AS091320 AS091345 AS092520 AS092545 AS093320 AS093345
0.22 μm0.45 μm0.22 μm0.45 μm0.22 μm0.45 μm
200200100100100100
Hydrophilic PTFE Syringe Filters13 mm
25 mm
33 mm
13 mm with glass prefi lter
25 mm with glass prefi lter
33 mm with glass prefi lter
AS081320 AS081345 AS082520 AS082545 AS083320 AS083345 AS081320-GAS081345-GAS082520-GAS082545-GAS083320-GAS083345-G
0.22 μm0.45 μm0.22 μm0.45 μm0.22 μm0.45 μm0.22 μm0.45 μm0.22 μm0.45 μm0.22 μm0.45 μm
200200100100100100200200100100100100
Membrane Type Pore Size Cat.No.Qty
007
Acc
esso
ries
and
Sup
plie
s
★ IC Syringe Filters
IC-Nylon Syringe Filters 13 mm
25 mm
IC021320IC021345IC022520IC022545
0.22 μm0.45 μm0.22 μm0.45 μm
200200100100
Membrane Type Pore Size Cat.No.Qty
★ Drying Filters
★ Metal Remover
★ Organic Remover
Hydrophobic PTFE Syringe Filters13 mm 25 mm
AD041345-TAD042545-T
0.45 μm0.45 μm
100100
Membrane Type Pore Size Cat.No.Qty
Hydrophobic PTFE Syringe Filters13 mm 25 mm
MR041345-TMR042545-T
0.45 μm0.45 μm
100100
Membrane Type Pore Size Cat.No.Qty
Nylon Syringe Filters13 mm 25 mm
OR021345-TOR022545-T
0.45 μm0.45 μm
100100
Membrane Type Pore Size Cat.No.Qty
Polypropylene Syringe Filters13 mm 25 mm 33 mm13 mm13 mm25 mm25 mm33 mm33 mm
AS201300AS202500AS203300AS201320AS201345AS202520AS202545AS203320AS203345
20 μm 20 μm 20 μm0.22 μm0.45 μm0.22 μm0.45 μm0.22 μm0.45 μm
200100100200200100100100100
Membrane Type Pore Size Cat.No.Qty
008
Acc
esso
ries
and
Sup
plie
s
Mixed Cellulose(Acetate And Nitrate)13 mm
25 mm
47 mm
AM011320AM011345AM012520AM012545AM014720AM014745
0.22 μm0.45 μm0.22 μm0.45 μm0.22 μm0.45 μm
200200200200100100
Membrane Type Pore Size Cat.No.Qty
Hydrophobic PVDF Syringe Filters
Polyethersulfone ( PES ) Syringe Filters
Hydrophobic PTFE Syringe Filters
Regenerated Cellulose ( RC ) Syringe Filters
13 mm
25 mm
13 mm
25 mm
13 mm
25 mm
13 mm
25 mm
AS931320AS931345AS932520AS932545
AS951320AS951345AS952520AS952545
AS941320AS941345AS942520AS942545
AS961320AS961345AS962520AS962545
0.22 μm0.45 μm0.22 μm0.45 μm
0.22 μm0.45 μm0.22 μm0.45 μm
0.22 μm0.45 μm0.22 μm0.45 μm
0.22 μm0.45 μm0.22 μm0.45 μm
9696100100
9696100100
9696100100
9696100100
Membrane FiltersOrdering Information
★ Sterilized Syringe Filters
Mixed Cellulose ( Acetate And Nitrate ) Syringe Filters
Nylon Syringe Filters
13 mm
25 mm
13 mm
25 mm
AS911320AS911345AS912520AS912545
AS921320AS921345AS922520AS922545
0.22 μm0.45 μm0.22 μm0.45 μm
0.22 μm0.45 μm0.22 μm0.45 μm
9696100100
9696100100
Membrane Type Pore Size Cat.No.Qty
009
Acc
esso
ries
and
Sup
plie
s
Hydrophobic PTFE
Polyethersulfone ( PES )
Regenerated Cellulose ( RC )
Hydrophilic PVDF
Hydrophilic PTFE
13 mm
25 mm
47 mm
13 mm
25 mm
47 mm
13 mm
25 mm
47 mm
13 mm
25 mm
47 mm
13 mm
25 mm
47 mm
AM041320AM041345AM042520AM042545AM044720AM044745
AM051320AM051345AM052520AM052545AM054720AM054745
AM061320AM061345AM062520AM062545AM064720AM064745
AM071320AM071345AM072520AM072545AM074720AM074745
AM081320AM081345AM082520AM082545AM084720AM084745
0.22 μm0.45 μm0.22 μm0.45 μm0.22 μm0.45 μm
0.22 μm0.45 μm0.22 μm0.45 μm0.22 μm0.45 μm
0.22 μm0.45 μm0.22 μm0.45 μm0.22 μm0.45 μm
0.22 μm0.45 μm0.22 μm0.45 μm0.22 μm0.45 μm
0.22 μm0.45 μm0.22 μm0.45 μm0.22 μm0.45 μm
200200200200100100
200200200200100100
200200200200100100
200200200200100100
200200200200100100
Membrane Type Pore Size Cat.No.Qty
Nylon
Hydrophobic PVDF
13 mm
25 mm
47 mm
13 mm
25 mm
47 mm
AM021320AM021345AM022520AM022545AM024720AM024745
AM031320AM031345AM032520AM032545AM034720AM034745
0.22 μm0.45 μm0.22 μm0.45 μm0.22 μm0.45 μm
0.22 μm0.45 μm0.22 μm0.45 μm0.22 μm0.45 μm
200200200200100100
200200200200100100
010
Acc
esso
ries
and
Sup
plie
s
■ 96-well Protein Precipitation Plates: The wide selectivity range of protein precipitation plates makes it possible to supply preparation methods for samples with complex matrices.■ Features and Applications: ★ Use chemical inert material, pH tolerance range: 1-13; ★ Compatible with automatic SPE or manual handling; ★ High throughput, superior to the traditional liquid-liquid extraction technique; ★ Dispense with stirring and centrifugal separation; ★ Larger specifi c surface area speeds up the extraction procedure; ★ Dispense with activating treatment.
96-Well Filtration Plates and Collection Plates
300500
AM3100AM5200
10002000
eaea
Funnel Volume (mL) Flask Volume (mL) Cat.No.Qty
The system includes a borosilicate glass funnel, a sintered borosilicate glass membrane core on the neck, aluminum clamp, and borosilicate glass fi lter fl ask. It can be used with or without a membrane fi lter depending on the application requirement to fi ltrate organic or aqueous solution. It is also used for liquid degassing.
Funnel volumes: 300 mL, 500 mLPore size of the glass membrane core: 10 μmFlask volumes: 1000 ml, 2000 mL
Glass Filtration System
Disposable Filtration Funnels with 10 μm Frits
Ordering Information
Ordering Information
Type
Filtration plate PP frits 20 μmFiltration plate PP frits 20 μmwith PTFE membrane 0.45 μm
2 mL
2 mL
96GL2025
96GL2025-F
2
2
Cat.No.QtyVol
SLC0006-FSLC0008-FSLC0025-FSLC0060-FSLC0150-F
6 mL10 mL25 mL60 mL150 mL
5050302020
Part No. Description Qty (PK)
011
Acc
esso
ries
and
Sup
plie
s
Vials and Seals
Bonna-Agela Technologies Inc. offers a number of high quality vials and seals. All of them are meet the high standard of the chromatographic applications. The difference of our offering from many other brand name venders is the cost to you. We offer lower price for the same products as many brand name’s due to our lean cost structure and we provide personal assist to you to select right products.
2 mL 12x32 mm Screw Neck Vials and Seals
Shell Vials and Seals
Screw neck vialScrew neck vialScrew neck vial, graduatedScrew neck vial, graduatedBlack screw cap, centre hole; Red silicone/white PTFE septa
1mL shell vial, 8mm PE-Plug
ClearAmberClearAmber
Clear
AV1000-6AV1010-0AV1001-6AV1011-0
AV2000-0
AV0100-6
Std 8-425Std 8-425Std 8-425Std 8-425
Std 8-425
Shell
Description
Description
Color
Color
Cat. No.(100/pk)
Cat. No.(100/pk)
Thread
Thread
300 μL PP Micro-vial300 μL PP Micro-vialScrew neck vialScrew neck vialScrew neck vial, graduatedScrew neck vial, graduatedScrew neck cap, center hole; red silicone/ white PTFE septaScrew neck cap, center hole; red silicone/ white PTFE septa, slittedScrew neck cap, closed top; red silicone/ white PTFE septa
TransparentAmberClearAmberClearAmber
Blue
Blue
Blue
AV1103-PAV1113-PAV1100-6AV1110-0AV1101-6AV1111-0
AV2100-0
AV2200-0
AV2300-0
short 9 mmshort 9 mmshort 9 mmshort 9 mmshort 9 mmshort 9 mm
short 9 mm
short 9 mm
short 9 mm
Description Color
Color
Cat. No.(100/pk)Thread
Vol.
8-425
8-425
AV1131-6
Short thread
Short thread
Inserts for 2 ml Short Thread Screw Vials
Insert, fl at bottom, 31x6 mm, for 9 mm vialsInsert, with assembled plastic spring, 29*6 mm
AV1130-6AV1131-6
Description Cat. No.(100/pk)
300 μL250 μL
ClearClear
012
Acc
esso
ries
and
Sup
plie
s
Color
Color
Vol.
Vol.
ND11 12x32 mm Snap Ring Vials and Seals
ND11 12x32 mm Crimp Neck Vials and Seals
PP snap ring Micro-vialPP snap ring Micro-vialSnap ring vial Snap ring vial Snap ring vial, graduatedSnap ring vial, graduatedPE snap ring cap, centre hole; white silicone/blue PTFE septa, slittedPEsnap ring cap, centre hole; red silicone/ white PTFE septa
Crimp neck vial Crimp neck vial Crimp neck vial, graduatedCrimp neck vial, graduatedAluminium cap, center hole; red silicone/white PTFE septaManual Crimper
300 μL300 μL2 mL2 mL2 ml2 mL
11 mm
11 mm
widewidewidewide
11 mm
11 mm
TransparentAmberClearAmberClearAmber
Transparent
Red
ClearAmberClearAmber
clear
lacquered
AV0003-PAV0013-PAV3000-6AV3101-0AV3001-6AV3011-0
AV4100-0
AV4201-0
AV5001-6AV5200-0AV5111-6AV5300-0
AV6110-0
AVC011-0
Description
Description
Color
Color
Vol.
Vol.
Cat. No.(100/pk)
Cat. No.(100/pk)
Screw Neck Vials and Seals
Screw Neck Vials and Seals
Screw neck vial, clear glassScrew neck vial, clear glass, graduatedScrew neck vial, amber glassScrew neck vial, amber glass, graduatedScrew neck cap, closed top; nature PTFE/nature silicone septaScrew neck cap, black, centre hole; red PTFE/white silicone septa
Screw neck vial, clear glassScrew neck vial, amber glassScrew neck cap, closed top; Red PTFE/white Silicone septa
AV7000-6AV7001-6AV7010-0AV7011-0
AV7400-0
AV7410-0
AV7500-6AV7510-7
AV1076-1514-B
Description
Description
Cat. No.(100/pk)
Cat. No.(100/pk)
4 mL 4 mL 4 mL 4 mL
13 mm
13 mm
12 mL 12 mL
15 mm
ClearClearAmberAmber
Black
Black
ClearAmber
Black
013
Acc
esso
ries
and
Sup
plie
s
2 mL Vial Rack (Cat. No AR0002-1)
ColorVol.
Screw neck vial, clear glass, 57*27.5 mmScrew neck vial, amber glass, 57*27.5 mmScrew neck vial, clear glass, 70*27.5 mmScrew neck vial, clear glass, 95*27.5 mmScrew neck vial, amber glass, 95*27.5 mmScrew neck vial, clear glass,140*27.5 mmScrew neck vial, amber glass,140*27.5 mmScrew caps, centre hole; nature PTFE/nature silicone septa, Screw caps, closed top; nature PTFE/ nature silicone septa,
AV7100-7AV7110-7AV7600-7AV7220-7AV7230-7AV7320-7AV7330-7
AV7910-0
AV7920-0
Description Cat. No.(100/pk)
20 mL 20 mL 25 mL40 mL 40 mL 60 mL 60 mL
¢ 22*3 mm
¢ 22*1.5 mm
ClearAmberClearClearAmberClearAmber
white
white
Headspace Vials and SealsColorVol.
Crimp neck headspace vial, 23*75.5 mm, rounded bottom (PE)Crimp neck headspace vial, 22.5*75.5 mm, long neck, rounded bottom Crimp neck headspace vial, long neck, fl at bottom, 22.5*75.5 mmAluminium cap, centre hole; nature silicone/ PTFE septaManual Crimper
AV8000-7
AV8100-7
AV8110-7
AV8800-0
AVC020-0
Description Cat. No.(100/pk)
20 mL
20 mL
20 mL
20 mm*3 mm
20 mm
clear
clear
clear
ColorVol.
Precision thread vials, rounded bottom 46*22.5 mmPrecision thread vials, rounded bottom 77.5*22.5 mmScrew cap, centre hole; White silicone/Blue PTFE septa
AV8500-0
AV8600-0
AV8900-0
Description Cat. No.(100/pk)
10 mL
20 mL
18 mm*1.5 mm
clear
clear
silver
Crimper for HS Crimp Vials
CrimperCrimper
AVC020-0AVC011-0
Product Description Cat. No.(100/pk)
for 20 mm crimp vialsfor 11 mm crimp vials
◆ Easy Handling◆ Chemical Resistance Surface◆ Long Service Lifetime◆ Crimping Pressure Adjustable by a Screw In the Handle
AVC011-0
Screw Neck Vials and Seals
014
Acc
esso
ries
and
Sup
plie
s
Pipettes and AccessoriesMechanical Pipette (Fixed Volume)
Mechanical Pipette (Adjustable Volume)Single Channel Pipette
8-Channel Pipette 12-Channel Pipette
A722001A722004A722010A722015A722020A722025
A722030A722035A722040A722045A722050A722055
510202550100
200250500100020005000
Cat No. Cat No.Volume (μL) Volume (μL)
A720005A720000A720020A720080A720050
A720210A720220A720240
A720070A720030A720060A720040A720110
A720310A720320A720340
0.1-2.50.5-105-502-2010-100
0.5-105-5050-300
0.050.10.50.51
0.10.55
115550
0.10.55
20-20050-200100-1000200-10001000-5000
0.5-105-5050-300
Cat No.
Cat No.
Cat No.
Cat No.
Volume (μL)
Volume (μL)
Increment (μL)
Increment (μL)
Increment (μL)
Increment (μL)
Volume (μL)
Volume (μL)
Pipette Tips
AD781348AD781349AD780006AD780007
AD780019AD780020AD780046
FT10 μLFT10 μLFT300 μLFT300 μL
FT1000 μLFT1000 μLFT1200 μL
Cat No. Cat No.Qty Qty
HPLC Accessories and Supplies
Bonna-Agela Technologies offers UV lamps of the same or better quality as a low cost replacement for many of those manufactured by original HPLC manufacturers, such as Shimadzu.
UV Lamps
Shimadzu
SPD-10 A, 2000 hLC2010, 2000 hSPD-20 A, 2000 hUV AA
SHL001SHL002SHL003SUV001
Original Instrument Part Number Agela Lamps Part Number
015
Acc
esso
ries
and
Sup
plie
s
Disposable Syringe for HPLC Filtration
HPLC Fittings and Tubing
ZSQ-5 MLLZSQ-2 ML
AF-120PM1960
PM1945R
SyringeSyringe
One-piece fi nger tight fi ttingsPEEK tubePEEK tube
----------Two-Piece Syringe
PEEKPEEK, yellow
PEEK, red
5 mL2 mL
1/16”, 10-321/16''OD, 0.010'' (0.25 mm) ID
1/16'', 0.005” (125 μm) ID
1010
Cat. No
Cat.No
Products
Prouduct
Description
Material
Specifi cation
Specifi cation
Package
■ High Quality■ Low Cost■ Convenient For Use■ Without Needle
LZSQ-2 ML ZSQ-5 ML
016
Acc
esso
ries
and
Sup
plie
s
GC ColumnsAnd
Accessories017
018
018
019
020
020
021
021
022
023
024
024
025
025
026
027
027
028
028
029
030
030
030
031
034
034
DA-1
DA-1MS
DA-5
DA-5MS
DA-35MS
DA-1701
DA-CarBoWax 20M
DA-FFAP
DA-INOWAX
DA-50+MS
DA-1301
DA-624
DA-PLOT Al2O3 “KCl”
DA-PLOT Al2O3 “M”
DA-PLOT Al2O3 “S”
DA-PLOT Mole Sieve
DA-PLOT GasPro
DA-Blood Alcohol Column
DA-PLOT Q
DA-PLOT U
GC Accessories And SuppliesSepta
Injection Port Liners
Ferrules
Column Scribe
1/32” Ultra Low Mass External Unions
017
Acc
esso
ries
and
Sup
plie
s
DA-1
● 100% bonded and crosslinked dimethylpolysiloxane● Non-polar, equivalent to USP phase G2● Solvent rinseable and high temperature limit● Wide range of column dimensions and stationary phase fi lm thicknesses● Low column bleed, inert surface and high effi ciency● Most polular for general applications
Similar Phases: DB-1, HP-1, Ultra-1, SPB-1, Rxi-1, CP-Si 5CB, BP-1, ZB-1, AT-1, MDN-1, OV-1, OV101
Ordering Information
ID(mm) Length(m) Film(μm) Temperature Limit(OC) Cat.No.
0.250.250.250.250.250.250.250.250.250.320.320.320.320.320.320.320.320.320.320.320.320.320.320.320.320.320.530.530.530.530.530.530.530.530.530.530.530.530.530.530.530.53
1515153030306060
1001515252525303030303030505050606060555
7.5101015151515303030303060
0.10.25
10.1
0.251
0.251
0.50.25
10.170.521.050.1
0.251345
0.170.521.050.25
15
0.150.882.65
50.882.650.151.535
0.881.5
2.65355
-60 to 325/350-60 to 325/350-60 to 325/350-60 to 325/350-60 to 325/350-60 to 325/350-60 to 325/350-60 to 325/350-60 to 325/350-60 to 325/350-60 to 325/350-60 to 325/350-60 to 325/350-60 to 325/350-60 to 325/350-60 to 325/350-60 to 325/350-60 to 325/280-60 to 325/280-60 to 325/280-60 to 325/350-60 to 325/350-60 to 300/320-60 to 325/350-60 to 300/320-60 to 260/280-60 to 325/360-60 to 325/360-60 to 260/280-60 to 260/280-60 to 300/320-60 to 260/280-60 to 320/360-60 to 300/320-60 to 260/280-60 to 260/280-60 to 300/320-60 to 300/320-60 to 260/280-60 to 260/280-60 to 260/280-60 to 260/280
0125-15010125-15020125-15100125-30010125-30020125-30100125-60020125-60100125-00100132-15020132-15100132-25010132-25050132-25100132-30010132-30020132-30100132-30300132-30400132-30500132-50010132-50050132-50100132-60020132-60100132-60500153-05010153-05080153-05260153-07500153-10080153-10260153-15010153-15150153-15300153-15500153-30080153-30150153-30260153-30300153-30500153-6050
018
Acc
esso
ries
and
Sup
plie
s
DA-1MS
DA-5
● Identical selectivity to DA-1, but with much lower column bleed● Ideal for GC-MS analysis and fi rst choice of new method development
● 5 % phenyl, 95 % methylpolysiloxane, bonded and crosslinked● Non-polar, equivalent to USP phase G27● Solvent rinsable and high temperature limit● Wide range of column dimensions and stationary phase fi lm thicknesses● Low column bleed, inert surface with neutral surface and high effi ciency● Most popular for general applications
Similar Phases: HP-1MS, DB-1MS, BPX-1, AT-1MS, ZB-1, Rxi-1, CP-Sil 5CB
Similar Phases: DB-5, HP-5, Ultra-5, SPB-5, Rxi-5, CP-Sil 8CB, BP-5, ZB-5, AT-5, MDN-5, OV-5, SE-52, SE-54
Ordering Information
Ordering Information
ID(mm) Length(m) Film(μm) Temperature Limit(OC) Cat.No.
-60 to 325/350-60 to 325/350-60 to 325/350-60 to 325/350-60 to 325/350-60 to 325/350-60 to 325/350-60 to 325/350-60 to 325/350-60 to 325/350-60 to 325/350-60 to 325/350
1125-15021125-30011125-30021125-30051125-30101125-60021132-15021132-25051132-30011132-30021132-30101132-6002
0.250.1
0.250.51
0.250.250.520.1
0.251
0.25
153030303060152530303060
0.250.250.250.250.250.250.320.320.320.320.320.32
ID(mm) Length(m) Film(μm) Temperature Limit(OC) Cat.No.
-60 to 325/350-60 to 325/350-60 to 325/350-60 to 325/350-60 to 325/350-60 to 325/350-60 to 325/350-60 to 325/350-60 to 325/350-60 to 325/350-60 to 325/350-60 to 325/350-60 to 325/350-60 to 325/350
0525-15020525-15100525-30010525-30020525-30100525-60020525-60100532-15020532-15100532-25010532-25050532-25100532-30010532-3002
0.251
0.10.25
10.25
10.25
10.170.521.050.1
0.25
1515303030606015152525253030
0.250.250.250.250.250.250.250.320.320.320.320.320.320.32
019
Acc
esso
ries
and
Sup
plie
s
ID(mm)
ID(mm)
Length(m)
Length(m)
Film(μm)
Film(μm)
Temperature Limit(OC)
Temperature Limit(OC)
Cat.No.
Cat.No.
-60 to 325/350-60 to 325/350-60 to 325/350-60 to 325/350-60 to 325/350-60 to 325/350-60 to 260/280-60 to 260/280-60 to 300/320-60 to 260/280-60 to 300/320-60 to 300/325-60 to 260/280-60 to 260/280
-60 to 325/350-60 to 325/350-60 to 325/350-60 to 325/350-60 to 325/350-60 to 325/350-60 to 325/350-60 to 325/350-60 to 325/350-60 to 325/350-60 to 325/350-60 to 325/350-60 to 325/350-60 to 325/350-60 to 325/350-60 to 325/350-60 to 325/350-60 to 325/350-60 to 325/350-60 to 325/350-60 to 325/350-60 to 325/350-60 to 325/350-60 to 325/350-60 to 325/350
0532-30050532-30100532-50010532-50050532-50100532-60020532-60100553-10260553-15150553-15500553-30080553-30150553-30260553-3050
1525-15011525-15021525-15051525-15101525-30011525-30021525-30051525-30101525-60011525-60021525-60051525-60101532-15011532-15021532-15051532-15101532-25051532-30011532-30021532-30051532-30101532-60011532-60021532-60051532-6010
0.51
0.170.521.050.25
12.651.55
0.881.5
2.655
0.10.250.51
0.10.250.51
0.10.250.51
0.10.250.51
0.520.1
0.250.51
0.10.250.51
3030505050606010151530303030
15151515303030306060606015151515253030303060606060
0.320.320.320.320.320.320.320.530.530.530.530.530.530.53
0.250.250.250.250.250.250.250.250.250.250.250.250.320.320.320.320.320.320.320.320.320.320.320.320.32
DA-5MS
● Identical selectivity to DB-5, but with much lower column bleed● Best surface inertness for wide range of compounds● Ideal for GC-MS analysis or new method developmentSimilar Phases: HP-5MS, DB-5MS, BPX-5MS, AT-5MS, Rxi-5MS, CP-Sil 8 CB
Ordering Information
020
Acc
esso
ries
and
Sup
plie
s
DA-35MS
DA-1701
● Bonded and 35 % phenyl backbone 65 % dimethylsiloxane phase● Equivalent to USP phase G42● Inert to many active compounds● Low column bleed to improve detection sensitivity and quantitation● Applications: Aroclors, PCBs, amines, pesticides, pharmaceutical molecules
● Bonded and crosslingked 14 % Cyanopropyl-phenyl 86 % dimethylsiloxane phase● Low to mid polarity● Inert to many active compounds● Applications: pesticides, herbicides, halogenates. Good confi rmation of analysis of active compounds on DA-5MS columns
Similar Phases: HP-35MS, DB-35, BPX-35, AT-35, Rxi-35, SPB-35
Similar Phases: DB-1701, ZB-1701, BP-10, Rxi-1701, CP-Sil 19 CB
Ordering Information
Ordering Information
ID(mm)
ID(mm)
Length(m)
Length(m)
Film(μm)
Film(μm)
Temperature Limit(OC)
Temperature Limit(OC)
Cat.No.
Cat.No.
40 to 320/34040 to 320/34040 to 320/34040 to 320/34040 to 320/34040 to 320/34040 to 320/34040 to 300/32040 to 300/32040 to 300/320
-20 to 280/300-20 to 280/300-20 to 280/300-20 to 280/300-20 to 280/300-20 to 280/300-20 to 280/300-20 to 280/300-20 to 280/300-20 to 280/300
3525-15023525-30013525-30023525-60023532-15023532-30023532-60023553-15103553-30053553-3010
6125-15016125-15026125-15106125-30016125-30026125-30106125-60016125-60026125-60106125-1501
0.250.150.250.250.250.250.25
10.51
0.150.25
10.150.25
10.150.25
10.15
15303060153060153030
15151530303060606015
0.250.250.250.250.320.320.320.530.530.53
0.250.250.250.250.250.250.250.250.250.32
021
Acc
esso
ries
and
Sup
plie
s
DA-CarBoWax 20M
DA-FFAP
● Polyethylene glycol (PEG), MW 20,000● Non-Bonded non-crosslinked phase ● Polar phase, equivalent to USP phase G16● Replacement of packed columns with Carbowax 20 M modifi ed
● Nitroterephthalic acid modifi ed Polyethylene glycol (PEG)● Bonded and crosslinked● Non-alcohol/aqueous solvent rinseable● High temperature limit● Polar phase equivalent to USP phase G35● Designed for the analysis of volatitle fatty acids and phenolsSimilar Phases: HP-FFAP, DB-FFAP, CB-WAX58 (FFAP) CB, Stabilwax-DA, BP-21, 007-CW, AT-100
Ordering Information
Ordering Information
ID(mm) Length(m) Film(μm) Temperature Limit(OC) Cat.No.
60 to 22060 to 22060 to 22060 to 22060 to 22060 to 21060 to 210
2220-25012220-50012225-30022232-25032232-50032253-10132253-3013
0.10.10.250.30.31.331.33
25503025501030
0.20.2
0.250.320.320.530.53
ID(mm) Length(m) Film(μm) Temperature Limit(OC) Cat.No.
60 to 240/25060 to 240/25060 to 240/25060 to 240/25060 to 240/25060 to 240/250
60 to 24060 to 24060 to 240
2125-15022125-30022132-15022132-25052132-30022132-50052153-10102153-15102153-3010
0.250.250.250.50.250.5111
153015253050101530
0.250.250.320.320.320.320.530.530.53
022
Acc
esso
ries
and
Sup
plie
s
ID(mm) Length(m) Film(μm) Temperature Limit(OC) Cat.No.
40 to 260/28040 to 260/28040 to 260/28040 to 260/28040 to 260/28040 to 260/28040 to 260/28040 to 260/28040 to 260/28040 to 260/28040 to 260/28040 to 260/28040 to 260/28040 to 260/28040 to 260/28040 to 260/28040 to 260/28040 to 260/28040 to 260/28040 to 260/28040 to 240/26040 to 240/26040 to 240/260
2020-25022020-25042020-50022020-50042025-15022025-15052025-30012025-30022025-30052025-60012025-60022025-60052032-15022032-15052032-30012032-30022032-30052032-60012032-60022032-60052053-15102053-30102053-6010
0.20.40.20.4
0.250.5
0.150.250.5
0.150.250.5
0.250.5
0.150.250.5
0.150.250.5111
2525505015153030306060601515303030606060153060
0.20.20.20.2
0.250.250.250.250.250.250.250.250.320.320.320.320.320.320.320.320.530.530.53
DA-INOWAX
● Bonded and crosslinked Polyethylene glycol (PEG)● Solvent washable● Highest temperature limits of bonded PEG phases● Polar phase, equivalent to USP phase G16● Wide applications of polar solvent analysis in food, pharma., cosmetics, petrochemical industriesSimilar Phases: HP-INNOWax, DB-WAX, DB-WAXetr, SupelcoWAX 10, CP-WAX, 52-CB, CB-WAX, Stablilwax, BP-20, 007-CW, AT-Wax, Rxi-Wax, ZB-Wax, HP-20M
Ordering Information
023
Acc
esso
ries
and
Sup
plie
s
ID(mm) Length(m) Film(μm) Temperature Limit(OC) Cat.No.
40 to 320/34040 to 320/34040 to 320/34040 to 320/34040 to 320/34040 to 320/34040 to 320/34040 to 320/34040 to 320/34040 to 320/34040 to 320/34040 to 320/34040 to 320/34040 to 320/34040 to 320/34040 to 320/34040 to 320/34040 to 320/34040 to 320/34040 to 320/34040 to 300/32040 to 300/32040 to 300/320
5020-12015020-12035020-25015020-25035020-50035025-15015025-15025025-15055025-30015025-30025025-30055025-60025032-15015032-15025032-15055032-30015032-30025032-30055032-60025032-60055053-15105053-30055053-3010
0.160.310.160.310.310.150.250.5
0.150.250.5
0.250.150.250.5
0.150.250.5
0.250.51
0.51
1212252550151515303030601515153030306060153030
0.20.20.20.20.2
0.250.250.250.250.250.250.250.320.320.320.320.320.320.320.320.530.530.53
DA-50+MS
● Bonded and crosslinked 50 % phenyl backbone 50 % dimethylsiloxane phase ● Equivalent to USP phase G3 ● Inert to many active compounds ● Low column bleed to improve detection sensitivity and quantization● Applications: Common drug screens, phenols, PAHs, free steroids, pesticides, herbicides. Good confi rmation of the analysis of active compounds on AB-5MS or AB-35MS columns Similar Phases: HP-50+, DB -7, DB-17MS, BPX-50, AT-50, Rxi-50, SPB-50
Ordering Information
024
Acc
esso
ries
and
Sup
plie
s
DA-1301
● Bonded and crosslinked 6 % Cyanopropyl-phenyl 94 % dimethylsiloxane phase ● Equivalent to USP phase G 43, low to mid polarity● Inert to many active compounds● Applications: pesticides, herbiciders, halogenates. Good confi rmation of the analysis of active compounds on DA-5MS or DA-35MS columns
Similar Phases: HP-1301, DB-1301, BP-10, Rxi-1301
Ordering Information
ID(mm) Length(m) Film(μm) Temperature Limit(OC) Cat.No.
-20 to 280/300-20 to 280/300-20 to 280/300-20 to 280/300-20 to 280/300-20 to 280/300-20 to 280/300-20 to 280/300-20 to 280/300-20 to 280/300-20 to 280/300-20 to 280/300-20 to 260/280-20 to 260/280-20 to 260/280
6025-15026025-15106025-30026025-30106025-60026025-60106032-15026032-15106032-30026032-30106032-60026032-60106053-15106053-30106053-3015
0.251
0.251
0.251
0.251
0.251
0.25111
1.5
151530306060151530306060153030
0.250.250.250.250.250.250.320.320.320.320.320.320.530.530.53
DA-624
● Bonded and crosslinked specially designed stationary phase for EPA methods● Mid-polarity● Inert to many active compounds● Applications: EPA methods: 501.3, 502.2, 503.1, 524.2, 601, 602, 8010, 8015, 8020, 8240,8260
Ordering Information
ID(mm) Length(m) Film(μm) Temperature Limit(OC) Cat.No.
-20 to 260-20 to 260-20 to 260-20 to 260-20 to 260-20 to 260-20 to 260-20 to 260
6220-25116225-30146225-60146232-30186232-60186253-30306253-60306253-7530
1.121.41.41.81.8333
2530603060306075
0.20.250.250.320.320.530.530.53
Similar Phases: DB-624, ZB-624, AT-624, Rxi-624, CP-624
025
Acc
esso
ries
and
Sup
plie
s
DA-PLOT Al2O3 “KCl”
DA-PLOT Al2O3 “M”
● Least selective ("polar") aluminum oxide phase● Deactivated with KCl ● Good baseline separation of most C1 to C10 hydrocarbons ● Olefi ns may co-elute with corresponding paraffi n over C5● Minimum surface adsorption of dienes and halocarbons ● ASTM recommended phase ● Preferred choice of hydrocarbon separation
● Strong selective (most "polar") aluminum oxide phase● Deactivated with Na2MoO4 salt ● Mostly baseline separation of C1 to C10 hydrocarbons, good baseline separation of cyclopropane from propylene ● Accurate quantitations of dienes and halocarbons ● ASTM recommended phase ● Preferred choice of hydrocarbon separation
Ordering Information
Ordering Information
ID(mm)
ID(mm)
Length(m)
Length(m)
Film(μm)
Film(μm)
Temperature Limit(OC)
Temperature Limit(OC)
Cat.No.
Cat.No.
-60 to 200/250-60 to 200/250-60 to 200/250
-60 to 200-60 to 200
-60 to 200/250-60 to 200-60 to 200-60 to 200
-60 to 200/250-60 to 200/250-60 to 200/250
-60 to 200-60 to 200
-60 to 200/250-60 to 200-60 to 200-60 to 200
8125-25058125-30058132-15088132-30088132-50088153-15158153-30158153-50158153-6015
8325-25058325-30058332-15088332-30088332-50088353-15158353-30158353-50158353-6015
5588815151515
5588815151515
253015305015305060
253015305015305060
0.250.250.320.320.320.530.530.530.53
0.250.250.320.320.320.530.530.530.53
Similar Phases: HP-PLOT Al2O3/KCl, GS-Alumina/KCl, CP-Al2O3/KCl PLOT, ZB-Alumina/KCl
Similar Phases: HP-PLOT Al2O3/"M", GS-Alumina, ZB-Alumina
026
Acc
esso
ries
and
Sup
plie
s
ID(mm) Length(m) Film(μm) Temperature Limit(OC) Cat.No.
-60 to 200/250-60 to 200/250-60 to 200/250
-60 to 200-60 to 200
-60 to 200/250-60 to 200-60 to 200-60 to 200
-60 to 200/250-60 to 200/250-60 to 200/250
-60 to 200-60 to 200
-60 to 200/250-60 to 200-60 to 200-60 to 200
8225-25058225-30058232-15088232-30088232-50088253-15158253-30158253-50158253-60158325-25058325-30058332-15088332-30088332-50088353-15158353-30158353-50158353-6015
55888
1515151555888
15151515
253015305015305060253015305015305060
0.250.250.320.320.320.530.530.530.530.250.250.320.320.320.530.530.530.53
DA-PLOT Al2O3 “S”
● Good selective (mid "polar") aluminum oxide phase● Deactivated with Na2SO4 salt● Excellent baseline separation of C1 to C10 hydrocarbons, excellent of C3, C4 isomer baseline separations ● Less accurate quantitations of dienes and halocarbons● ASTM recommended phase● Preferred choice of hydrocarbon separation Similar Phases: HP-PLOT Al2O3/"S", GS-Alumina, CP-Al2O3/Na2SO4 PLOT, ZB-Alumina, RT-Alumina
Ordering Information
027
Acc
esso
ries
and
Sup
plie
s
Ordering Information
ID(mm) Length(m) Film(μm) Temperature Limit(OC) Cat.No.
-80 to 300-80 to 300-80 to 300-80 to 300-80 to 300-80 to 300-80 to 300-80 to 300-80 to 300-80 to 300
8432-05128432-15128432-30128432-15258432-30258453-05258453-15258453-30258453-15508453-3050
12121225252525255050
515301530515301530
0.320.320.320.320.320.530.530.530.530.53
DA-PLOT GasPro
● Proprietary Silica base phase● Very inert to wide range of gases including sulfur gases and Freons, symmetric peak shapes● Truly immobilized coating and smooth baseline workable for valve switching● Preferred column to analyze sulfur gases from hydrocarbon streams and air● Separation of CO and CO2
● No effect of water on retention time ● Regeneration of performance from water adsorptions at 250℃ for 3hr ● ASTM recommended phase● GC-MS applicableSimilar Phases: GS-GasPro, CP-Silica PLOT
Ordering Information
ID(mm) Length(m) Film(μm) Temperature Limit(OC) Cat.No.
-80 to 260/300-80 to 260/300-80 to 260/300
8532-05058532-15058532-3005
555
51530
0.320.320.32
DA-PLOT Mole Sieve
● Molecular Sieve, Zeolite, 5A● Thin and thick coatings for push limit separations, e.g. Ar/O2 separation at 35C, O2/N2 with 15sec ● Truly immobilized coating and smooth baseline workable for valve switching ● Preferred column to analyze fi xed gases from hydrocarbon streams ● Elution order, H2, He, Ne, O2, N2, CH4, CO - Regeneration of performance from water/CO2 adsorptions at 250℃ for 3hr● ASTM recommended phase ● Noble gas, air from methane, fuel cell, etc● Often used with other PLOT columns for fi xed gas separation from sample matrix
Similar Phases: HP-PLOT Al2O3/"S", GS-Alumina, CP-Al2O3/Na2SO4 PLOT, ZB-Alumina, RT-Alumina
028
Acc
esso
ries
and
Sup
plie
s
DA-PLOT Q
● Divinylbenzene polymer particle, non-polar, close to traditional PoraPak Q ● Truly immobilized coating and smooth baseline workable for valve switching and liquid sample introduction at low temperatures● Highest temperature limit, up to 280/300℃● Baseline separation of Air, CO2, water, sulfur gases, hydrogen chlorine, ammonia/light amines from hydrocarbons such as refi nery stream, natural gas, and engine exhaust● Excellent separation of C1 to C3 isomers, good separations of C3 to C12, halocarbons● Excellent inertness and long lifetime of water/alcohol sample, a good secondary choice of wax column for alcohol analysis● Excellent tolerance to strong acid/base sample without affecting retention time● Good anti-oxidation at 280℃ and fast regeneration of performance ● Observed slight sulfur gas, hydrogen chlorine, and amine absorption● Water peak is tailing, but no effect on retention● Good choice for analyzing low level solvent residues from wide samples, such as headspace, aqueous, or organic solutions● Preferred column for residue analysis in petroleum industry, pharmaceutical, environmental, chemical weapon detection● Preferred column to analyze polar compounds including oxygenates from hydrocarbon streams: natural gas, refi nery gas, dienes, ethylene, propyleneSimilar Phases: HP-PLOT Q, GS-Q, CP-PoraPLOT Q HT, Supel PLOT Q, Rt-Q, ZB-PLOT Q
Ordering Information
ID(mm) Length(m) Film(μm) Temperature Limit(OC) Cat.No.
-80 to 280/290-80 to 280/290-80 to 280/290-80 to 280/290
8632-15158632-30158653-15308653-3030
15153030
15301530
0.320.320.530.53
DA-Blood Alcohol Column
● Proprietary PLOT phase ● Reliable blood alcohol analysis● Tolerance of direct sample injection● Excellent confi rmation column to other blood alcohol columns using t-butanol as internal standard
Ordering Information
ID(mm) Length(m) Film(μm) Temperature Limit(OC) Cat.No.
-80 to 260/280 8932-0710107.50.32
029
Acc
esso
ries
and
Sup
plie
s
DA-PLOT U
● Divinylbenzene and Ethylene glycol dimethacrylate copolymer particle, polar, close to traditional PoraPack U● Truly immobilized coating and smooth baseline workable for valve switching and liquid sample introduction at low temperatures● Improved separation and selectivity of Air, CO2, water, sulfur gases, hydrogen chlorine, ammonia/light amines from hydrocarbons● Symmetric water peak shape, water elute after C3● Excellent separation of C1 to C3 isomers, good separations of C3 to C12, halocarbons● Excellent inertness and long lifetime of water/alcohol sample, a good secondary choice of wax column for alcohol analysis● Excellent tolerance to strong acid/base sample without affecting retention time● Observed slight sulfur gas, hydrogen chlorine, and amine absorption● Good choice for analyzing low level solvent residues from wide samples, such as headspace, aqueous, or organic solutions● Preferred column for residue analysis in petroleum industry, pharmaceutical, environmental, chemical weapon detection● Preferred column to analyze polar compounds including oxygenates from hydrocarbon streams: natural gas, refi nery gas, dienes, ethylene, propylene Similar Phases: HP-PLOT U, CP-PoraPLOT U
Ordering Information
ID(mm) Length(m) Film(μm) Temperature Limit(OC) Cat.No.
-80 to 190/200-80 to 190-80 to 190
-80 to 190/200-80 to 190
8732-15108732-30108732-30208753-15208753-3020
1010202020
1530301530
0.320.320.320.530.53
030
Acc
esso
ries
and
Sup
plie
s
GC Accessories and Supplies
Septa
Septa BTO
Advanced Green 3
B02-1002B02-1040B02-1031B02-1001B02-1032
B02-1006B02-1005B02-1041
B02-3004B02-3005B02-3007B02-3008B02-3009B02-3011B02-3012B02-3013B02-3015B02-3019B02-3020
1 / pk 5 / pk10 / pk 1 / pk 5 / pk10 / pk 1 / pk 5 / pk10 / pk 1 / pk 5 / pk
Septa BTO 5 mm Center guide (50 / pk)Septa BTO 3/8" (9.5 mm) (50 / pk)Septa BTO 11.5 mm Center guide (50 / pk)Septa BTO 11 mm (7/16") Center guide (50 / pk)septa BOT 17 mm, Center guide
Septa AG3 5 mm Center guide (50 / pk)Septa AG3 11 mm (7/16") Center guide (50 / pk)Septa AG3 3/8" (9.5 mm) (50 / pk)
Liner, 4 mm, 79 mm length, Single Taper w/Sil WoolLiner, 4 mm, 79 mm length, Single Taper w/Sil WoolLiner, 4 mm, 79 mm length, Single Taper w/Sil WoolLiner, 4 mm, 79 mm length, Double TaperLiner, 4 mm, 79 mm length, Double TaperLiner, 4 mm, 79 mm length, Double TaperLiner, 4 mm, 79 mm length, Single TaperLiner, 4 mm, 79 mm length, Single TaperLiner, 4 mm, 79 mm length, Single TaperLiner, 4 mm, 79 mm length, with Silanized WoolLiner, 4 mm, 79 mm length, with Silanized Wool
Cat.No.
Cat.No.
Cat.No. Qty.
Description
Description
Description
Extended temperature range, low-bleed
Extended temperature range, low-bleed
● Maximun temperature 400℃● Virtually eliminates injection-port sticking● Preconditioned packaged in glass to prevent contamination
● True low-bleed, high temperature green septum. ● Maximum temperature 400℃
● Each batch GC-FID tested.● Ideal for use with low-bleed, “Mass Sepc” capillary columns
Injection Port Liners
Organosilane deactivated borosilicate glass (quartz where notes). Guaranteed inertness for phenols, organic acids and bases. Glass wool is also deactivated. These capillary injection port liners provide a clean, non-adsorptive surface for your samples. Regular replacement of the liner protects your capillary columns from potentially harmful non-volatiles that might otherwise deposit on your columns.
For Agilent Capillary GC Instruments
031
Acc
esso
ries
and
Sup
plie
s
B02-3022B02-3030B02-3031B02-3032B02-3033B02-3034B02-3036
10 / pk 1 / pk 5 / pk10 / pk 1 / pk 5 / pk10 / pk
Liner, 4 mm, 79 mm length, with Silanized WoolLiner, 2 mm, 79 mm length, Splitless, GlassLiner, 2 mm, 79 mm length, Splitless, GlassLiner, 2 mm, 79 mm length, Splitless, GlassLiner, 2 mm, 79 mm length, Splitless, QuartzLiner, 2 mm, 79 mm length, Splitless, QuartzLiner, 2 mm, 79 mm length, Splitless, Quartz
Cat.No. Qty.Description
B02-3201B02-3202B02-3203B02-3204B02-3205B02-3206B02-3207B02-3208B02-3209B02-3210B02-3211B02-3212
B02-3103B02-3104B02-3105B02-3112B02-3113B02-3114B02-3115B02-3116B02-3117B02-3118B02-3119B02-3120
1/16" to 0.3 mm ferrules1/16" to 0.4 mm ferrules1/16" to 0.5 mm ferrules1/16" to 0.8 mm ferrules1/16" to 1.0 mm ferrules1/16" to 1.2 mm ferrules1/16" to 0.4 mm -Agilent style1/16" to 0.5 mm -Agilent style1/16" to 0.8 mm -Agilent style
B02-2126B02-2127B02-2128B02-2129B02-2130B02-2131B02-2012B02-2013B02-2014
1 / pk 5 / pk10 / pk 1 / pk 5 / pk10 / pk 1 / pk 5 / pk10 / pk 1 / pk 5 / pk10 / pk
1 / pk 5 / pk10 / pk 1 / pk 5 / pk10 / pk 1 / PK 5 / PK10 / PK 1 / pk 5 / pk10 / pk
Liner, 4 mm Split, 92 mm length,Autosystem for PerkinElmer GCLiner, 4 mm Split, 92 mm length,Autosystem for PerkinElmer GCLiner, 4 mm Split, 92 mm length,Autosystem for PerkinElmer GCLiner, 4 mm Split, 92 mm length Autosystem w/Wool for PerkinElmer (ea)Liner, 4 mm Split, 92 mm length Autosystem w/Wool for PerkinElmer (ea)Liner, 4 mm Split, 92 mm length Autosystem w/Wool for PerkinElmer (ea)Liner, 2 mm Splitless, 92 mm length,Autosystem for PerkinElmer GCLiner, 2 mm Splitless, 92 mm length,Autosystem for PerkinElmer GCLiner, 2 mm Splitless, 92 mm length,Autosystem for PerkinElmer GCLiner, 100 mm, Dimple Spliter for PerkinElmer GCSLiner, 100 mm, Dimple pliter for PerkinElmer GCLiner, 100 mm, Dimple Spliter for PerkinElmer GC
4 mm Open Split w/Sil. Wool for Varian 1075/10774 mm Open Split w/Sil. Wool for Varian 1075/10774 mm Open Split w/Sil. Wool for Varian 1075/1077Liner, Frit Split for Varian 1075/1077Liner, Frit Split for Varian 1075/1077Liner, Frit Split for Varian 1075/1077Liner, 4 mm Open Split, for Varian 1075/1077Liner, 4 mm Open Split, for Varian 1075/1077Liner, 4 mm Open Split, for Varian 1075/1077Liner, 74 mm length, Splitless, Glass for Varian 1075/1077 (ea)Liner, 74 mm length, Splitless, Glass for Varian 1075/1077 (ea)Liner, 74 mm length, Splitless, Glass for Varian 1075/1077 (ea)
Cat.No.
Cat.No.
Qty.
Qty.
Description
Description
For Perkin-Elmer Capillary GCs
For Varian Capillary GCs
Vespel Ferrules-Sold In Packages Of 10
Ferrules
● Upper temperature limit: 350℃● 100% high-temperature DuPont polyimide● Fairly hard; tends to seal● permanently to the column
Capillary Column Ferrules Cat.No.
032
Acc
esso
ries
and
Sup
plie
s
1/16" ferrules1/8" ferrules1/4" ferrules
1/8" to 0.4 mm Vespel1/8" to 0.5 mm Vespel1/8" to 0.8 mm Vespel1/8" to 1/16" Vespel1/4" to 1/16" ferrules1/4" To 1/8" ferrules
B02-2125B02-2133B02-2141
B02-2135B02-2136B02-2137B02-2138B02-2143B02-2144
Straight Ferrules-for tubing with ODs as listed
Agilent style—Short ferrule, especially for Agilent inlet systems: 4890,5890 and 6890
Straight Ferrules-for tubing with ODs as listed
Short Ferrules for Agilent Inlets
Capillary Column Ferrules
Reducing Ferrules
Reducing Ferrules
Cat.No.
B02-2101B02-2109B02-2116
B02-2001B02-2002B02-2003B02-2004
B02-2102B02-2103B02-2104B02-2105B02-2106
B02-2110B02-2111B02-2112B02-2113B02-2117B02-2118B02-2119B02-2120B02-2121B02-2122B02-2123B02-2124
1/16" Graphite Ferrule1/8" Graphite Ferrule1/4" Graphite Ferrule
1/16" to 0.4 mm Graphite Ferrule1/16" to 0.5 mm Graphite Ferrule1/16" to 0.8 mm Graphite Ferrule1/16" to 1.0 mm Graphite Ferrule
1/16" to 0.4 mm Graphite Ferrule1/16" to 0.5 mm Graphite Ferrule1/16" to 0.8 mm Graphite Ferrule1/16" to 1.0 mm Graphite Ferrule1/16" to 1.2 mm Graphite Ferrule
1/8" to 0.4 mm Graphite Ferrule1/8" to 0.5 mm Graphite Ferrule1/8" to 0.8 mm Graphite Ferrule1/8" to 1/16" Graphite Ferrule1/4" to 1.0 mm Graphite Ferrule1/4" to 0.4 mm Graphite Ferrule1/4" to 0.5 mm Graphite Ferrule1/4" to 0.8 mm Graphite Ferrule1/4" to 1/16" Graphite Ferrule1/4" to 1/8" Graphite Ferrule1/4" to 6.0 mm Graphite Ferrule1/4" to 4.0 mm Graphite Ferrule
Cat.No. Description
Graphite Ferrules—Sold 10/pack Except as Noted
Ordering Information
● Upper temperature limit: 450℃● High-purity Graphite; Preferred for capillary GC use● Ideal for glass-to-metal connections; doesn't stick to glass● Reusable if not over-tightened
033
Acc
esso
ries
and
Sup
plie
s
Straight Ferrules-for tubing with ODs as listed
Short Ferrules for Agilent Inlet
Capillary Column Ferrules
Reducing Ferrules
B02-2145B02-2153B02-2160
B02-2005B02-2006B02-2007
B02-2146B02-2147B02-2148B02-2149B02-2150
B02-2154B02-2155B02-2156B02-2157B02-2161B02-2162B02-2163B02-2164B02-2166B02-2167
1/16" V/G Ferrules1/8" V/G Ferrules1/4" V/G
1/16" to 0.4 mm V/G Ferrules1/16" to 0.5 mm V/G Ferrules1/16" to 0.8 mm V/G
1/16" to 0.4 mm V/G Ferrules1/16" to 0.5 mm V/G Ferrules1/16" to 0.8 mm V/G1/16" to 1.0 mm V/G Ferrules1/16" to 1.2 mm V/G
1/8" to 0.4 mm V/G Ferrules1/8" to 0.5 mm V/G Ferrules1/8" to 0.8 mm V/G1/8" to 1/16" V/G Ferrules1/4" to 0.4 mm V/G1/4" to 0.5 mm V/G1/4" to 6.0 mm V/G Ferrules1/4" to 0.8 mm V/G Ferrules1/4" to 1/16" V/G Ferrules1/4" to 1/8" V/G
Cat.No. Description
Vespel/Graphite Ferrules –Sold in Packages of 10
Ordering Information
● Upper temperature limit: 450℃● Made from quality DuPont polyimide/graphite blend● Recommended for GC/MS interface applications
Straight Ferrules-for tubing with ODs as listed
Capillary Column Ferrules
B02-2169B02-2176B02-2182
B02-2170B02-2171B02-2172B02-2173B02-2174B02-2175
1/16" Tefl on1/8" Tefl on1/4" Tefl on
1/16" to 0.3 mm Tefl on1/16" to 0.4 mm Tefl on1/16" to 0.5 mm Tefl on1/16" to 0.8 mm Tefl on1/16" to 1.0 mm Tefl on1/16" to 1.2 mm Tefl on
Cat.No. Description
Tefl on Ferrules –Sold In Packages of 10
Ordering Information
● Upper temperature limit: 250℃● 100% Tefl on; completely inert
034
Acc
esso
ries
and
Sup
plie
s
Reducing FerrulesB02-2177B02-2178B02-2179B02-2180B02-2183B02-2185B02-2186B02-2187
1/8" to 0.4 mm Tefl on1/8" to 0.5 mm Tefl on1/8" to 0.8 mm Tefl on1/8" to 1/16" Tefl on1/4" to 6 mm Tefl on1/4" to 1/16" Tefl on1/4" To 1/8" Tefl on1/4" to 3/16" Tefl on
Cat.No. Description
Description
Column Scribe
Used to cut capillary tubing. Simply pull one smooth edge of the hard ceramic scribe (tilted about 45 degrees) across the column to lightly score the fused silica .Bend the column opposite the score and the column separate cleanly.
Ordering Information
B02-1006 Column Scribe, 10 / pk
Cat.No.
1/32” Ultra Low Mass External Unions
For capillary tubing 0.1 to 0.32 mm I.D. It has very low mass and can be hand-tightened to seal.Use only with 1/32” fused silica adapters; metal ferrules cannot be used.
Ordering Information
Description
B02-4001B02-4002B02-4003B02-4004B02-4005B02-4006
1/32" Union, Bore 0.25 mm1/32" Union, Bore 0.50 mm1/32" Union, Bore1/32" 1/32" Fused Silica Tubing Adapter Tubing o.d.<0.25 mm1/32" Fused Silica Tubing Adapter Tubing o.d. 0.25-0.4 mm1/32" Fused Silica Tubing Adapter Tubing o.d. 0.5 mm
Cat.No.
2
Acc
esso
ries
and
Sup
plie
s
Top Related