Download - 1'-0 1'-0 1'-0 1'-0 PANDA RESTAURANT GROUP INC. · 2017. 9. 5. · planting beds and project limits. these plans are schematic. contractor shall size all pipe. b.100% coverage of

Transcript
Page 1: 1'-0 1'-0 1'-0 1'-0 PANDA RESTAURANT GROUP INC. · 2017. 9. 5. · planting beds and project limits. these plans are schematic. contractor shall size all pipe. b.100% coverage of

F

1'-0" 1'-0" 1'-0" 1'-0"

1'- 0

"

Typ

.

EXAMPLE

PLAN VIEW

ARCH PROJECT #:

PANDA PROJECT #:

DRAWN BY:

ISSUE DATE:

REVISIONS:

All ideas, designs, arrangement and plans indicated orrepresented by this drawing are the property of Panda ExpressInc. and were created for use on this specific project. None ofthese ideas, designs, arrangements or plans may be used by ordisclosed to any person, firm, or corporation without the written

permission of Panda Express Inc.

1683 Walnut Grove Ave.Rosemead, California 1770

Telephone: 626.799.9898Facsimile: 626.372.8288

PANDA RESTAURANT GROUP INC.

ARCHITECT:

10955 LOWELL AVENUE, SUITE 700 OVERLAND PARK, KS 66210

ph: 913.649.8181 • fx: 913.649.1275

ENGINEERLICENSE #

PERMIT SUBMITTAL 06.09.171ST

PANDA EXPRESSE. 144th AVENUE and GRANT STREET

THORNTON, CO 80023

S8-17-D534717044.002

TRUE WARM & WELCOME 2200

PE

RM

IT

S

UB

MIT

TA

L 0

6.0

9.1

7

PE.0052142

O

P

O

R

LAN

O

I

S

S

E

F

E

E

N

I

G

N

E

LO

D

A

R

O

L

N

D

E

S

E

C

I

R

A

R

K

S

.JO

H

N

S

O

N

C

M

7101 College Blvd., Suite 400Overland Park, Kansas 66210

p. (913) 663-1900 f. (913) 663-1633BHC RHODES is a trademark of Brungardt Honomichl & Company, P.A.

IRRIGATION NOTES

1. THE SYSTEM DESIGN ASSUMES A MINIMUMAVAILABLE STATIC PRESSURE FOR THE IRRIGATIONSYSTEM OF 45 PSI AT THE 3/4 INCH METER.CONTRACTOR TO VERIFY PRESSURE AND FLOWON SITE PRIOR TO CONSTRUCTION AND REPORTAND DISCREPANCIES BETWEEN THESEASSUMPTIONS AND ACTUAL FIELD CONDITIONS INWRITING TO THE OWNER'S REPRESENTATIVE.

2. READ THOROUGHLY AND BECOME FAMILIARWITH THE SPECIFICATIONS AND INSTILLATIONDETAILS FOR THIS AND RELATED WORK PRIOR TOCONSTRUCTION.

3. COORDINATE LOCATION AND MARKING OFUNDERGROUND UTILITIES PRIOR TOCONSTRUCTION. NOTIFY THE OWNER'SREPRESENTATIVE OF ANY CONFLICT WITH ANYUNDERGROUND UTILITY.

4. DO NOT PROCEED WITH THE INSTILLATION OFTHE IRRIGATION SYSTEM WHEN IT IS OBVIOUS INTHE FIELD THAT OBSTRUCTIONS OR GRADEDIFFERENCES EXISTING THAT MIGHT NOT HAVEBEEN CONSIDERED IN THE ENGINEERING, OR IFDISCREPANCIES IN CONSTRUCTION DETAILS,LEGEND, NOTES, OR SPECIFICATIONS AREDISCOVERED. BRING ALL SUCH OBSTRUCTIONS ORDISCREPANCIES TO THE ATTENTION OF THEOWNER'S REPRESENTATIVE IN WRITING PRIOR TOCONSTRUCTION.

5. THESE DRAWINGS ARE DIAGRAMMATIC.THEREFORE, THE FOLLOWING SHOULD BE NOTED:A. AVOID CONFLICTS BETWEEN THE IRRIGATION

SYSTEM, PLANTING MATERIALS ANDARCHITECTURAL FEATURES. INSTILL IRRIGATIONPIPE AND WIRING IN LANDSCAPED AREASWHENEVER POSSIBLE.

B. USE ONLY STANDARD TEES AND ELBOWFITTINGS. USE OF CROSS TYPE FITTINGS ISNOT PERMITTED.

C. IRRIGATION PIPE AND VALVES MAY BE SHOWNOUTSIDE OF THE PLANTING AREA, IN THEHARDSCAPE OR OUTSIDE OF PROPERTY LINESFOR GRAPHIC CLARITY ONLY. INSTALL ALLIRRIGATION COMPONENTS WITHINLANDSCAPES AREAS OR THROUGH SLEEVINGAND WITHIN THE PROPERTY BOUNDARY.

6. PROVIDE THE FOLLOWING COMPONENTS TO THEOWNER'S REPRESENTATIVE PRIOR TO THECOMPLETION OF THE PROJECT.

A. TWO OPERATING KEYS FOR EACH TYPE OFMANUALLY OPERATED VALVES.

B. TWO OF EACH SERVICING WRENCH OR TOOLNEEDED FOR COMPLETE ACCESS,ADJUSTMENT, AND REPAIR OF ALL SPRINKLERSAND EMITTERS.

7. SELECT NOZZLES FOR SPRAY AND ROTARYSPRINKLES WITH ARCS THAT PROVIDE COMPLETEAND UNIFORM COVERAGE WITH MINIMUMOVERSPRAY FOR THE SITE CONDITIONS. TOMINIMIZE OVERSPRAY, INSTALL PRESSURECOMPENSATING NOZZLES OR CONDITIONS. TOMINIMIZE OVERSPRAY, INSTALL PRESSURECOMPENSATING NOZZLES OR PRESSURECOMPENSATING SCREENS IF UNIFORM LATERALPRESSURE CANNOT BE ATTAINED WITH PRESSUREADJUSTMENT AT THE REMOTE CONTROL VALVE.CAREFULLY ADJUST THE RADIUS OF THE THROWAND ARC OF COVERAGE OF EACH SPRAY ANDROTARY SPRINKLER TO PROVIDE THE BESTPERFORMANCE.

8. THE IRRIGATION CONTRACTOR IS RESPONSIBLEFOR COORDINATING WITH THE GENERALCONTRACTOR FOR THE INSTILLATION OFIRRIGATION SLEEVING. ALL SLEEVING WILL BESCHEDULE 40 PVC. ALL PIPE AND WIRE WILL BEINSTALLED IN SEPARATE SLEEVES AT ALL PAVEDSURFACES, SIDEWALKS, DRIVEWAYS, WALLSFOOTINGS AND HARDSCAPE AREAS. ALL SLEEVESMAY NOT BE SHOWN AND/OR SIZED IN THEPLANS. THE GENERAL CONTRACTOR ISRESPONSIBLE FOR COORDINATING WITH THEIRRIGATION CONTRACTOR FOR THE INSTILLATIONOF ALL REQUIRED SLEEVING, PROPER SIZING ANDCOORDINATE INSTILLATION OF SLEEVING WITHOTHER TRADES. ANY PIPE OR WIRE WHICHPASSES BENEATH EXISTING HARDSCAPE WHERESLEEVING WAS NOT INSTALLED, REQUIRESHORIZONTAL BORING BY THE IRRIGATIONCONTACTOR. SLEEVE AND CONDUIT SIZES SHALLBE A MINIMUM OF TWICE THE AGGREGATEDIAMETER OF ALL PIPE AND WIRE CONTAINEDWITHIN SLEEVE OR CONDUIT PIPE. MINIMUMSLEEVE SIZE IS 2-INCH. INDICATE ALL SLEEVELOCATIONS ON “AS-BUILT” RECORD DRAWINGS.

9. COORDINATE AND INSTALL ALL ELECTRICALPOWER TO THE IRRIGATION CONTROL SYSTEM INACCORDANCE WITH THE NATIONAL ELECTRICCODE AND ALL APPLICABLE LOCAL ELECTRIC

UTILITY CODES.10. GATE VALVES SHALL BE PORTED TO PROVIDE FOR

FULL FLOW. LABELED AND NOMINAL SIZE OFVALVE OPENING SHALL BE THE SAME.

11. ALL MATERIALS AND WORKMANSHIP SHALL BETRUE TO TYPE, FORM, FINISH AND OF THEHIGHEST STANDARDS OF THE TRADE. DAMAGEDOR INFERIOR MATERIALS SHALL BE REMOVEDFROM THE SIRE WITHOUT DELAY.

12. INSTALL PRESSURE REGULATING MODULE FORALL DRIP VALVE ASSEMBLIES. SET DISCHARGEPRESSURE TO 35 PSI.

13. INSTALL IRRIGATION PIPE AND COMPONENTS AMINIMUM OF 8 FEET FROM TREE ROOT BALLS.PIPE ROUTINGS SHOWN ON DRAWINGS ISDIAGRAMMATIC.

14. PROVIDE #12-1 AWG BARE COPPER TRACINGWIRE ALONG THE ENTIRE MAINLINE ROUTING.PROVIDE 24 INCH COIL OF TRACING WIRE INEACH VALVE BOX ALONG MAINLINE ROUTING.

15. CONTRACTOR SHALL FURNISH AND INSTALLMATERIAL AND EQUIPMENT PERTAINING TO THEIRRIGATION SYSTEM HEREIN SPECIFIED ORSHOWN ON THE DRAWINGS. THIS SHALL INCLUDEALL ITEMS NECESSARY TO COMPLETEINSTILLATION.

16. IRRIGATION CONTRACTOR TO CAP ALL FLUSHENDS HAND TIGHT PRIOR TO BACKFILL.

17. IRRIGATION CONTRACTOR SHALL COORDINATEWORK WITH PLANTING PLANS TO AVOIDCONFLICTING LOCATIONS BETWEEN PIPING ANDPLANT PITS.

18. ALL MATERIALS SHALL BE INSTALLED AS DETAILEDIN THE PLANS. IF THE CONTRACT DRAWINGSAND/OR SPECIFICATIONS DO NOT THOROUGHLYDESCRIBE THE METHOD OR TECHNIQUES TO BEUSED, THEN THE CONTRACTOR SHALL INSTALL ASPER MANUFACTURERS SPECIFICATIONS. IF THECONTRADICTION OCCURS, NOTIFY THELANDSCAPE ARCHITECT IMMEDIATELY.

19. IRRIGATION CONTRACTOR TO USE TEFLON TAPEON ALL THREADED JOINTS.

20. NO PIPES SHALL BE INSTALLED PARALLEL ANDDIRECTLY OVER ANOTHER LINE.

21. BRAND EACH VALVE BOX WITH 1” LETTERINGSHOWING ZONE NUMBER AND CONTROLLERLETTER. THIS STAMP IS TO MATCH THE ZONEAND CONTROLLER ASSOCIATES WITH THE VALVE'S

OPERATION.22. CONTRACTOR SHALL PERFORM THE FOLLOWING:

A. VISIT SITE AND VERIFY EXISTING GRADES,CONSTRUCTION AND CONDITIONS.

B. NOTIFY LANDSCAPE ARCHITECT OFDISCREPANCIES BETWEEN PLAN AND FIELDCONDITIONS.

C. RESTORE CONTRACTOR DAMAGED EXISTINGWORK TO THE SATISFACTION OF THEENGINEER OR LANDSCAPE ARCHITECTWITHOUT COST TO THE OWNER.

D. BE SATISFIED THAT THE PLAN CAN BECONSTRUCTED, FUNCTIONAL AND COMPLETE.

23. ALL EQUIPMENT SHALL BE MAINTAINED WHILEUNDER CONSTRUCTION. MAINTENANCE INCLUDES:WATER SCHEDULING, REPLACEMENT OFDEFECTIVE OR DAMAGED EQUIPMENT,ADJUSTMENT AND RE-ADJUSTMENT OF HEADSAND OTHER EQUIPMENT.

24. CONTRACTOR TO ENSURE THE FOLLOWING:A. LINES AND VALVES ARE TO BE PLACED WITHIN

PLANTING BEDS AND PROJECT LIMITS. THESEPLANS ARE SCHEMATIC. CONTRACTOR SHALLSIZE ALL PIPE.

B. 100% COVERAGE OF IRRIGATION SYSTEM TOALL PLANTS REGARDLESS OF SIZE OR TYPEAND SHALL CONFIRM ALL NON-IRRIGATEDAREAS PRIOR TO SUBMITTING A BID.

25. INSTALL TWO (2) SPARE #14-1 AWG CONTROLWIRES FOR EACH UNUSED STATION AND ONESPARE #12-1 AWG COMMON WIRE FROM THERESPECTIVE CONTROLLER TO HIS LOCATION FORUSE AS A SPARE WIRES IN EACH REMOTECONTROL VALVE BOX ALONG THE ENTIRE WIREROUTING FOR THIS CONTROLLER. SEAL WIREENDS WATER TIGHT AND CONTAIN WITHINVALVE BOX AT THIS LOCATION.

26. SHOULD FIELD ADJUSTMENTS BE MADE TO THESIRE PLAN, IRRIGATION CONTRACTOR SHALLMAKE ALL NECESSARY ADJUSTMENTS TO THEIRRIGATION SYSTEM TO ENSURE PROPERFUNCTIONALITY. LANDSCAPE ARCHITECT IS TO BENOTIFIED OF ANY AND ALL CHANGES MADE TOTHE IRRIGATION SYSTEM, PRIOR TO INSTILLATIONOF SAID CHANGES.

ICZ-101 DRIP CONTROL ZONE DRIP LINE PARKING LOT ISLAND LAYOUT VALVE BOX LAYOUT

L2.3

IRRIGATION DETAILS 2

NAB

06/15/2017