ZTE EMS GSM Data Configuration V1.0

41
GSM Data Configuration Editor: Cola Wong

description

ZTE OPTIMIZATION CLUES

Transcript of ZTE EMS GSM Data Configuration V1.0

Page 1: ZTE EMS GSM Data Configuration V1.0

GSM Data Configuration

Editor: Cola Wong

Page 2: ZTE EMS GSM Data Configuration V1.0

GSM Neighbor Cells

Make Backup Config in BSC Function BCCH Frequency Modify TCH Frequency Modify 2G Dump file Export 2G Dump file Import 2G Radio Parameters 2G External Cell Configuration 2G Adjacent Cell Configuration 2G External&Adjacent Cell Configuration Import Switch Configuration Synchronize Modified Data

Page 3: ZTE EMS GSM Data Configuration V1.0

Make Backup Config in BSC Function1.Log in ZTE EMS, Configuration on toolbar to click NE Management

Page 4: ZTE EMS GSM Data Configuration V1.0

Make Backup Config in BSC Function2.Select BSC or RNC, right click to Start NE Management

Page 5: ZTE EMS GSM Data Configuration V1.0

Make Backup Config in BSC Function3.Finish “Start NE Management”, right click Configuration Management

Page 6: ZTE EMS GSM Data Configuration V1.0

Make Backup Config in BSC Function4.Shown below is Open Configuration Management, click + to show more details

Page 7: ZTE EMS GSM Data Configuration V1.0

Make Backup Config in BSC Function5.Finish clicking “+” you will see all functions on OMCR

Page 8: ZTE EMS GSM Data Configuration V1.0

Make Backup Config in BSC Function6. Apply Mutex Right in order to Operate action

Page 9: ZTE EMS GSM Data Configuration V1.0

Make Backup Config in BSC Function7.Get Mutex Right from EMS, show “Green lock”

Page 10: ZTE EMS GSM Data Configuration V1.0

Make Backup Config in BSC Function8. Right click “Config Set XXX”—Subtree Copy

Page 11: ZTE EMS GSM Data Configuration V1.0

Make Backup Config in BSC Function9.Back to BSC Management to right click to Subtree Duplicate –Subtree Paste

Page 12: ZTE EMS GSM Data Configuration V1.0

Make Backup Config in BSC Function10. Subtree Paste Progress

Page 13: ZTE EMS GSM Data Configuration V1.0

Make Backup Config in BSC Function11.Finish “Subtree Paste”, new Backup Config will be shown under Master Config

Page 14: ZTE EMS GSM Data Configuration V1.0

BCCH Frequency Modify

Page 15: ZTE EMS GSM Data Configuration V1.0

TCH Frequency Modify

Page 16: ZTE EMS GSM Data Configuration V1.0

2G Dump file Export1.Export 2G Dump file(Network Plan Data) on BSC Function by right click

Page 17: ZTE EMS GSM Data Configuration V1.0

2G Dump file Export2.Select sub-sheet or all sheet

Page 18: ZTE EMS GSM Data Configuration V1.0

2G Dump file Export3.Click OK

Page 19: ZTE EMS GSM Data Configuration V1.0

2G Dump file Export4.Select format of Exporting

Page 20: ZTE EMS GSM Data Configuration V1.0

2G Dump file Export5.Save route for Dump files of exporting

Page 21: ZTE EMS GSM Data Configuration V1.0

2G Dump file Import1.Select Import function

Page 22: ZTE EMS GSM Data Configuration V1.0

2G Dump file Import2.Select import file’s format

Page 23: ZTE EMS GSM Data Configuration V1.0

2G Radio Parameters1. BSC Level Parameters

Page 24: ZTE EMS GSM Data Configuration V1.0

2G Radio Parameters2.Site Level Parameters

Page 25: ZTE EMS GSM Data Configuration V1.0

2G Radio Parameters3.Cell Level Parameter (Power Control,HO Control,TRXs etc)

Page 26: ZTE EMS GSM Data Configuration V1.0

2G Radio Parameters4.Handover Control Parameters

Page 27: ZTE EMS GSM Data Configuration V1.0

2G Radio Parameters5.SDCCH Handover Control Parameters

Page 28: ZTE EMS GSM Data Configuration V1.0

2G External Cell Configuration1. Check specific BSC all GERAN External Cell Config

Page 29: ZTE EMS GSM Data Configuration V1.0

2G External Cell Configuration2. Check External Ncells information

Page 30: ZTE EMS GSM Data Configuration V1.0

2G Adjacent Cell Configuration1.Check specific Cell’s Adjacent Cells under Cell level parameter

Page 31: ZTE EMS GSM Data Configuration V1.0

2G Adjacent Cell Configuration2.Show Adjacent Cells belong to Specific Cell(e.g.EN0010A)

Page 32: ZTE EMS GSM Data Configuration V1.0

2G External&Adjacent Cells Import 1.Right Click “BSC Function” with Mutex avaible --- “Import Config Data”--- “Batch Apply Network Plan Data”

Page 33: ZTE EMS GSM Data Configuration V1.0

2G External&Adjacent Cells Import 2.Select file to import

Page 34: ZTE EMS GSM Data Configuration V1.0

2G External&Adjacent Cells Import 3.Show for External import file when realize on EMS

Page 35: ZTE EMS GSM Data Configuration V1.0

2G External&Adjacent Cells Import 4.Show for Adjacent import file when realize on EMS

Page 36: ZTE EMS GSM Data Configuration V1.0

Clarification for External and Adjacent Cell Configuration1.Must Define External first,and then Define Adjacent ncells

2.Must Delete External first,and then Delete Adjacent ncells

ENZBSC13 ADD NeighborHoResel-1009

ENZBSC13 ExternalGsmCell-1009

Attach that import templete for Adjacent and External cells

Parameters

Values on EMS

900 1800

Frequency band(FreqBand) 0 2

Max power level of MS(MsTxPwrMax) 5 0

Parameters

Handover Forward

900-900 900-1800 1800-900

MIN threshold of signal level for handover on PBGT(HoMarginPbgt) 29 36 20

Adjacent cell handover and reselection ID(HoResObjectId) Range from 1 to 64 cycle use

Ncells Modified Relative Parameters

Page 37: ZTE EMS GSM Data Configuration V1.0

Switch Configuration1.Select Backup Config,double click will be seen right side

Page 38: ZTE EMS GSM Data Configuration V1.0

Switch Configuration2.Click lable to switch to be Master Config

Page 39: ZTE EMS GSM Data Configuration V1.0

Synchronize Modified Data1.Finish Modification

Page 40: ZTE EMS GSM Data Configuration V1.0

Synchronize Modified Data2.Apply Mutex,right click, “Config Data Managed Element”— “Synchronize Modified Data”

Page 41: ZTE EMS GSM Data Configuration V1.0