*47255399* 47255399 © Allegion 2019 Printed in U.S.A. 47255399 Rev. 03/19-d Customer Service 1-877-671-7011 www.allegion.com/us Models 320, 350, 7350, 351, 352, 360, 361, 362, 364, 365, 366, 367, 368, & 369 Automatic Door Bottoms 1” 1. Cut the automatic door bottom (ADB) to the size needed. Leave 1/16” (1.6 mm) clearance on each end. 2. Place the ADB on the door. All surface and semi-mortised units must be mounted on the push side of the door (side where the door stop is). 3. Fasten with screws provided. The adjusting brass nut must be on the hinge side and should not be adjusted until the unit has been mounted. 4. Optimum clearance between door bottom unit and floor or sill is 3/8” (9.5 mm). For model #369 clearance is 5/8” (15.9 mm). 5. Final adjustment to control the drop of the automatic door bottom can be made once the unit is installed, by turning the adjusting brass nut in or out. Open and close the door while adjusting the brass nut to get the desired seal with the floor or sill. Do not over adjust. TRIMMING INSTRUCTIONS Trim from LOCK SIDE ONLY Set screw Maximum cut should NOT be closer than 1” (25.4 mm) to the set screw or 3.5" for models 367, 368, and 369. Adjusting brass nut must be on HINGE SIDE #8 x 1.500"(31.8)SMS .722"(18.3) 1.793" (45.5) #8 x 1.500"(38.1) SMS 1.901" (48.3) .916"(23.3) #8 x 1.500"(38.1) SMS #8 x 1.500"(38.1) SMS 1.901" (48.3) .916"(23.3) Steel Plate Magnet 1.901" (48.3) .916"(23.3) Max. Effective Drop .875"(22.2) 1.750" (44.5) .719" (18.3) 1.750" (44.5) 1.00"(24.5) Max. Effective Drop .875"(22.2) Max. Effective Drop .875"(22.2) .375" (9.5) #351AA #351BK #351D #351G #361AA #361B #361D #361G #365AA #365BK #365D #365FS #365G #367AA #367BK #367D #367G End Cap for #351 End Cap for #361, #365, #367 Surface-Mounted Installation Instructions Surface-Mounted Automatic Door Bottom With Watershed Option L Note: #8361 Locking Key can’t be used with end caps. 2.81" (71.4) 0.94" (23.8) #8361 Locking Key #366A #141A OPTIONS End Cap For #362, #366, #368 installed with #141 <13DL> Positive Pressure Tested Gasketing Materials For Fire Doors. For application to hollow metal type fire doors rated up to 3 hours, fiberglass or wood composite type fire doors rated up to 1-1/2 hours and wood type fire doors rated up to 20 minutes. Category J .722"(18.3) 1.793" (45.5) 1.901" (48.3) 1.901" (48.3) Steel Plate Magnet 1.901" (48.3) .916"(23.3) .916"(23.3) .916"(23.3) 1.750" (44.5) .719" (18.3) 1.750" (44.5) 1.00"(24.5) #8x1.500"(38.1) SMS #8 x 1.500"(38.1) SMS #8 x1.500"(38.1) SMS #8 x 1.500"(38.1) SMS Max. Effective Drop .875"(22.2) Max. Effective Drop .875"(22.2) Max. Effective Drop .875"(22.2) .375" (9.5) Semi-Mortised #352AA #352BK #352D #352G #362AA #362BK #362D #362G #366AA #366BK #366D #366G #368AA #368BK #368D #368G End Cap for #352 End Cap for #362, # 366, #368 * Listing applicable for all models except #7350

Transcript of Zero Automatic Door Bottoms Models 320, 350, 7350, 351, 352, … · 2020. 12. 21. · L Note: #8361...

  • *47255399*47255399

    © Allegion 2019Printed in U.S.A.

    47255399 Rev. 03/19-dCustomer Service

    1-877-671-7011 www.allegion.com/us

    Models 320, 350, 7350, 351, 352, 360, 361, 362, 364, 365, 366, 367, 368, & 369 Automatic Door Bottoms

    1”

    1. Cut the automatic door bottom (ADB) to the size needed. Leave 1/16” (1.6 mm) clearance on each end.

    2. Place the ADB on the door. All surface and semi-mortised units must be mounted on the push side of the door (side where the door stop is).

    3. Fasten with screws provided. The adjusting brass nut must be on the hinge side and should not be adjusted until the unit has been mounted.

    4. Optimum clearance between door bottom unit and floor or sill is 3/8” (9.5 mm). For model #369 clearance is 5/8” (15.9 mm).

    5. Final adjustment to control the drop of the automatic door bottom can be made once the unit is installed, by turning the adjusting brass nut in or out. Open and close the door while adjusting the brass nut to get the desired seal with the floor or sill. Do not over adjust.

    TRIMMING INSTRUCTIONS Trim from LOCK SIDE ONLY

    Set screw

    Maximum cut should NOT be closer than 1” (25.4 mm) to the set screw or 3.5" for models 367, 368, and 369.

    Adjusting brass nut must be on HINGE SIDE

    #8 x 1.500"(31.8)SMS.722"(18.3)

    1.793"(45.5)

    #8 x 1.500"(38.1) SMS

    1.901"(48.3)

    .916"(23.3)#8 x 1.500"(38.1) SMS#8 x 1.500"(38.1) SMS

    1.901"(48.3)

    .916"(23.3)

    Steel Plate

    Magnet

    1.901"(48.3)

    .916"(23.3)

    Max. E�ective Drop.875"(22.2)

    1.750"(44.5)

    .719"(18.3)

    1.750"(44.5)

    1.00"(24.5)

    Max. E�ective Drop.875"(22.2)

    Max. E�ective Drop.875"(22.2)

    .375"(9.5)

    #351AA#351BK

    #351D#351G

    #361AA#361B#361D#361G

    #365AA#365BK#365D#365FS#365G

    #367AA#367BK#367D#367G

    End Cap for #351End Cap for #361, #365, #367Surface-Mounted

    Installation Instructions

    Surface-Mounted Automatic Door Bottom With Watershed Option

    L Note: #8361 Locking Key can’t be used with end caps.

    2.81"(71.4)

    0.94"(23.8)

    #8361 Locking Key

    #366A

    #141A

    OPTIONS

    End CapFor #362, #366, #368installed with #141

    Positive Pressure Tested Gasketing Materials For Fire Doors.For application to hollow metal type fire doors rated up to 3 hours, fiberglass or wood composite type fire doors rated up to 1-1/2 hours and wood type fire doors rated up to 20 minutes. Category J

    .722"(18.3)

    1.793"(45.5)

    1.901"(48.3)

    1.901"(48.3)

    Steel Plate

    Magnet

    1.901"(48.3)

    .916"(23.3).916"(23.3).916"(23.3)

    1.750"(44.5)

    .719"(18.3)

    1.750"(44.5)

    1.00"(24.5)#8x1.500"(38.1) SMS #8 x 1.500"(38.1) SMS#8 x1.500"(38.1) SMS #8 x 1.500"(38.1) SMS

    Max. E�ective Drop.875"(22.2)

    Max. E�ective Drop.875"(22.2) Max. E�ective Drop.875"(22.2)

    .375"(9.5)

    Semi-Mortised#352AA#352BK

    #352D#352G

    #362AA#362BK#362D#362G

    #366AA#366BK#366D#366G

    #368AA#368BK#368D#368G

    End Cap for #352 End Cap for #362,# 366, #368

    * Listing applicable for all models except #7350

  • #6x.750"(19.1) #6x.750"(19.1)

    .705"(17.9)

    .375"(9.5) 1.250"

    (31.8)

    Steel Plate

    .371"(9.4)

    1.575"(40.0)

    .924"(23.5)

    .371"(9.4)

    1.575"(40.0)

    Max. E�ective Drop.875"(22.2)

    .924"(23.5)

    .371"(9.4)

    1.575"(40.0)

    .924"(23.5)

    1.250"(31.8)

    2.250"(57.2)

    1.50"(38.1)

    1.750"(44.5)

    1.50"(38.1)

    1.498"(38.0) 1.378"

    (35.0)

    .595"(15.1)

    #6x.750"(19.1) #6x.750"(19.1)Max. E�ective Drop

    .875"(22.2)Max. E�ective Drop

    .875"(22.2)

    Magnet

    Mortised #350AA #7350AA #364AA#364FS

    End Cap for #350, #360, #364, #369

    #360AA#320AA

    End Cap for #320

    #369AA

    Suggested door cutout C\v" x 1>\zn"

    Suggested door cutout 1" x 1B\,"

    Suggested door cutout 1" x 1B\,"

    Suggested door cutout 1" x 1B\,"

    Suggested door cutout 11/16”x17/16”

    Models 321, 323 Automatic Door Bottoms - Handed

    .4375”

    .598”

    1.563”

    1.969”

    ø

    End Caps for #321

    (50.0)

    (39.7)

    (15.2)

    Surface-Mounted

    #321AAHanded

    (L.H. shown)

    .595"(15.1)

    Neoprene

    Zeroquiet seal

    .062"(1.6)

    Max. drop.750"(19.1)

    #8 x 1.50”(38.1) TPHSMS

    2.00"(50.8)

    Mortised

    #323AHanded (L.H. shown)

    Max. drop.750"(19.1)

    .595"(15.1)

    Zeroquiet seal

    Neoprene

    .062"(1.6)

    #6 x .750”(19.1) PPHSDS

    1.458"(37.0)

    .375"(9.5)

    *

    * Max. cut should not closer than 1” (25.4mm) to the set screw.

    TRIMMING INSTRUCTIONS

    After the unit has been mounted, thread the adjusting nut out until the seal contacts the floor/sill when the door is closed. Take care not to thread the adjusting too far out as that can damage the door bottom.

    FINAL ADJUSTMENT

    NOTE: Handing must be determined prior to trimming.

    TO INSTALL:

    1 Surface mounted unit must be mounted on the push side of the door stop (side where the door stop is).

    2 The brass adjusting nut must be on the hinge side and should not be adjusted until the unit has been mounted.

    3 Leave 1/16" (1.6) clearance on each end.

    4 Optimum clearance between door bottom unit andfloor or sill is 3/8" (9.5).

    Positive Pressure Tested Gasketing Materials For Fire Doors. For application to hollow metal type fire doors rated up to 3 hours, fiberglass or wood composite type fire doors rated up to 1-1/2 hours and wood type fire doors rated up to 20 minutes. Category J

  • 4.25

    5.500

    FRONT

    Additional Notes: Revision History Revision Description:D > Revised artwork

    1. None A B C D E F

    xxxxx 062679

    MaterialWhite Paper

    Edited By Approved By EC Number Release Date

    J. Ellis M. Roberts 062679 03-27-19

    Notes1. printed two sides2. printed black3. tolerance ± .134. printed in country may vary5. drawings not to scale

    Title

    Zero automatic door bottoms installation instructionCreation Datexx-xx-xx

    Number

    47255399Revision

    DCreated ByX. XXXXX

    Activity3899 Hancock Expwy

    Security, CO 80911 © Allegion 2019Software: InDesign CS6

    8.500

    11.000

    BEGINNING SHEET FOLDED SHEET

    FRONT