ZenPure - Q-Test

222
ZenPure ZenPure Innovation, Speed, Flexibility, and Reliability A Unique Provider of Filtration, Purification and Membrane Device Solutions Product Catalog 2012 WWW.ZENPURE.COM ISO9001/14001/13485 ®

Transcript of ZenPure - Q-Test

Page 1: ZenPure - Q-Test

ZenPureZenPure

Innovation, Speed, Flexibility, and Reliability

A Unique Provider of Filtration, Purification and Membrane Device Solutions

Product Catalog 2012 WWW.ZENPURE.COM

ISO9001/14001/13485

®

Page 2: ZenPure - Q-Test

Our Capabilities and Services ZenPure is vertically integrated developer and manufacturer of filtration and purification products, and specialty membrane devices. ZenPure capabilities include: Custom product design and development, tooling, process and equipment engineering, OEM and private label services. We focus on speed and extreme flexibility to meet customers' challenging needs in performance and fast time to market.

Industries served With our technical and applications know-how in filter performances, coupled with all in-house design and development, engineering, and manufacturing capabilities, we have been able to serve diversified industries worldwide, including: • Medical and Medical equipment • Pharmaceuticals • Chemical and Industrial • Food and Beverages

Specializing in Custom Products ZenPure works with both small and large companies to design, develop, and produce custom products. We provide service from concept and prototype through to production: • Rapid product turn around • Reliable processes and quality control • Design for optimum efficiency and cost • Dependable service and technical support The success and satisfaction of our customers is our highest priority.

Page 1

Page 3: ZenPure - Q-Test

ZenPure Z

en

Pu

re

Table of Contents

Capsule Description Filter PrefixCatalog Page

Number

ZenPure Media Options Information 5

ZenPure Capsule Size Options Information 6

PureFlo Filtration Discs CN, DP, E, F, M, N, NS, P, HF, S*** 7

PureFlo Filter Cups FS*** 8

PureFlo D4 Disc Capsule D4*** 10

PureFlo D13 Disc Capsule D13R*** 11

PureFlo D13U Disc Capsule D13U*** 12

PureFlo D25C Disc Capsule D25C*** 13

PureFlo D25U Disc Capsule D25U*** 14

PureFlo D40C Disc Capsule D40C*** 15

PureFlo D50C Disc Capsule D50C*** 16

PureFlo G50C Disc Capsule G50C*** 17

PureFlo D65R Disc Capsule D65R*** 19

Silicon Heater for D65 D65-SHS80501 21

PureFlo Junior Capsule JKL, JNL, JKP*** 22

PureFlo MKL Capsule MKL, MKP*** 24

PureFlo MKL Capsule PE MKPE***-E 26

ZenPure Vent & Drain Info for SK Capsules Information 28

PureFlo SKV Series PES Capsule, Pharma Grade SKVS*** 32

PureFlo SKV Series PES Capsule, Pharma Grade, with PE SKVS***-E 34

PureFlo SKL Series PES Capsule, Pharma Grade SKLS***-PH 36

PureFlo SKL Series PES Capsule, Biological Reduction Grade SKLS***-B 38

PureFlo SKL Series PES Capsule, Standard Grade SKLS*** 40

PureFlo SKV Series PTFE Capsule SKVF** 42

PureFlo SKL Series PTFE Capsule SKLF** 44

PureFlo SKL Series Nylon Capsule SKLN** 46

PureFlo SKV Series Nylon Capsule SKVN*** 48

PureFlo SNL Series All Nylon Capsule SNLN** 50

PureFlo SNV Series All Nylon Capsule SNVN** 52

PureFlo SKL Series Nylon Screen Capsule SKLNS*** 54

PureFlo SKL Series PE Capsule SKLE*** 56

PureFlo SKL Series Glass MicroFiber Capsule SKLG*** 58

PureFlo SKL Series PP Membrane Capsule SKLM*** 61

PureFlo SKL Series PP Media Capsule SKLP*** 62

PureFlo SKL Series Mini Depth pleated PP Media Capsule SKDP*** 64

PureFlo HEPA Capsule SKH*** 66

PureFlo Carbon Fiber/HEPA Capsule SKC***, SKCH***, MKC*** 68

PureFlo Lenticular Cloud D65R Disc Capsule D65CEP*** 70

PureFlo SKV Series Lenticular Cloud Capsule SKVCEP*** 72

PureFlo SKL Series Lenticular Cloud Capsule SKLCEP*** 73

ZenCap Lenticular Cloud Capsule L**CEP*** 75

ZenCap LT and LI Capsule L*** 78

Specialty FiltersPureFlo Ink Capsule IFC*** 80

PureFlo Tank Vent Purifier SKCL 82

PureFlo Shower Filter SKVPS*** 84

PureFlo SVV Void Capsule SVV*** 87

PureFlo SVL Void Capsule SVL*** 88

PureFlo ZenCap Void Filter Capsule LV*** 89

PureFlo SKML Mulit-Zone Capsule SKML*** 90

PureFlo SKMV Mulit-Zone Capsule SKMV*** 92

PureFlo EDF Capsule EDF*** 94

Page 2

Page 4: ZenPure - Q-Test

ZenPure Z

en

Pu

re

Table of Contents

Cartridge DescriptionFilter

Prefix

Catalog Page

Number

PureFlo Mini Lenticular Cloud Filter MCEP*** 74

PureFlo Lenticular Cloud Filter CEP*** 76

PureFlo Junior Cartridge MJ*** 96

PureFlo Polypropylene membrane Cartridge MCP*** 98

PureFlo Polypropylene Media Cartridge NCP*** 100

PureFlo Depth Pleated PP cartrdige NDP*** 102

PureFlo Industrial PP Cartridge NIP*** 104

PureFlo PTFE Filter Cartridge MCF*** 106

PureFlo Hi Temp PTFE Filter Cartridge Nylon Construction MNF*** 108

PureFlo Hi Temp PTFE Filter Cartridge w/SS Core MSF*** 110

PureFlo Hi Temp PTFE Filter Cartridge w/Hi=Temp PP Construction MBF*** 112

PureFlo PE Cartridge MCE*** 115

PureFlo Nylon Cartridge MCN*** 116

PureFlo Nylon Plus Cartridge MNN*** 118

PureFlo All-Nylon Cartridge MSN*** 120

PureFlo Charged Nylon Cartridge EPN*** 122

PureFlo Charged Nylon Cartridge MPN*** 122

PureFlo PES Cartridge MCS*** 124

PureFlo PES Pharma Grade Cartridge MCS*** -PH 126

PureFlo PES Pharma Grade Cartridge Dual Layer MPS***-PH 126

PureFlo PES Biological Reduction Grade Cartridge MCS*** -B 128

PureFlo PES Beverage Grade Cartridge MBS*** 130

PureFlo EPS Cartridge EPS*** 132

PureFlo General Grade Cartridge MGS*** 134

PureFlo Water Grade Cartridge MWS*** 136

PureFlo Glass MicroFiber Cartridge NCG*** 138

Thermally Bonded PP JT*** 140

Thermally Bonded PP LF-PP** 142

PureFlo Activated Carbon Fiber WCC*** 143

String Wound Filter Cartridge SW*** 144

PureFlo Mini Cartridge Configuration Information Information 147

PureFlo Polypro Membrane Mini Cartridge MMP*** 148

PureFlo Polypro Media Mini Cartridge NMP*** 150

PureFlo Mini Depth Pleated PP Cartridge JDP*** 152

PureFlo PTFE Mini Filter Cartridge MMF*** 154

PureFlo PTFE Mini Vent Cartridge MVF*** 156

PureFlo PE Mini Vent Cartridge MVE*** 156

PureFlo PE Mini Cartridge MME*** 158

PureFlo Nylon Mini Cartridge MMN*** 160

PureFlo Charged Nylon Mini Cartridge EMN*** 162

PureFlo PES Mini Cartridge MMS*** 164

PureFlo Glass MicroFiber Mini Cartirdge NMG*** 166

Page 3

Page 5: ZenPure - Q-Test

ZenPure Z

en

Pu

re

Table of Contents

Bag Filter DescriptionFilter

Prefix

Catalog Page

NumberMAXX PP Microfiber Element for Bag Filter Housing PMF*** 169

MAXX Glass Fiber Element for Bag Filter Housing BMF*** 170

MAXX PP Felt Element for BaG Filter Housing PPF*** 171

MAXX Polyester Felt Element for Bag Filter Housing PEF*** 171

MAXX Phenolic Polyester Element for Bag Filter Housing PTP*** 172

Hi-Pro Micro Felt Bag Filter HPM*** 174

Polyester Felt Bag Filter PE*** 176

Polypropylene Felt Bag Filter PP*** 176

Nylon mono-filiment Mesh Bag Filter NMO*** 178

Polyester mono-filiment Mesh Bag Filter PEMO*** 178

Polypropylene mono-filiment Mesh Bag Filter POMO*** 178

Nylon Multi-filiment Mesh Bag Filter NMU*** 178

Polyester Multi-filiment Mesh Bag Filter PEMU*** 178

Polyester Chem Bag PE***-CB 180

Polypropylene Chem Bag PP***-CB 180

Resinator Bag Filter BRB*** 182

Housing DescriptionFilter

Prefix

Catalog Page

NumberStainless Steel Disc Holder DH*** 184

Stainless Steel Disc Media Holder DMP*** 185

Virgin Polypropylene Housing PHV010*** 186

Sanitary Mini Stainless Steel Housing SMP01*** 188

Sanitary Stainless Steel Housing SHP01*** 190

Sanitary SS Filter Housing Multi-round SAN*** 192

Industrial Stainless Steel Housing IHP01*** 193

Industrial High Purity SS Housing Multi-round IHP*** 195

Industrial Economy Filter Housing Multi-round IE*** 196

Band Clamp SS Filter Housing Multi-round GTCHB*** 197

Industrial High Purity Bag Filter Housing IHPB*** 198

SRL Series Bag Housing SRL*** 200

SRS Series Bag Housing SRS*** 201

SRH Series Bag Housing SRH*** 202

SRM Series Multi-cavity Housing SRM*** 203

Portable Filter Bag Cart CUSTOM 204

Industrial High Purity Vent Housing IHP1IV*** 205

Sanitary Stainless Steel Vent Housing SVP017*** 206

Sample & Vent Valves OFSB*** 208

Sanitary Y-Strainer SYS*** 210

InformationFilter

Prefix

Catalog Page

NumberZenPure Media Options Information 5

ZenPure Capsule Size Options Information 6

ZenPure Vent & Drain Info for SK Capsules Information 28

PureFlo Mini Cartridge Configuration Information Information 147

Benefits of Electropolishing Information 212

Chemical Compatability Table Information 213

Terms & Conditions Information 216

Trademarks Information 218

Page 4

Page 6: ZenPure - Q-Test

ZenPure ZenPure Media Options

Zen

Pu

re

C = Carbon Fiber

CEP = Cellulose w/DE

CN = Charged Nylon

DP = Depth Polypropylene

E = Polyethylene

F = PTFE

G = Glass Fiber

HF = Philic PTFE

M = PP Membrane

N = Nylon

NP = PP Nano Fiber

NS = Nylon Screen

P = PP Media

S = PES

SS = Stainless Steel

TS = Polyester Screen

Carbon

Fiber (C )

Cellulose

w/DE (CEP)

Charged Nylon

(CN)

Depth PP

(DP)

Polyethyle

ne (E)PTFE (F)

Glass Fiber

(G)Philic PTFE

(HF)

015 = 0.15 005 = 0.05 002 = 0.2 020 = 0.20 010 = 0.1 005 = 0.5 Request

040 = 0.40 010 = 0.10 005 = 0.5 100 = 1.0 020 = 0.2 010 = 1.0050 = 0.50 020 = 0.20 010 = 1.0 150 = 1.5 045 = 0.45 030 = 3.0060 = 0.60 045 = 0.45 015 = 1.5 250 = 2.5 100 = 1.0 050 = 5.0085 = 0.85 065 = 0.65 025 = 2.5 300 = 3.0 100 = 10.0150 = 1.50 080 = 0.80 045 = 4.5 500 = 5.0 200 = 20.0250 = 2.50 120 = 1.20 100 = 10 999 = 10.0 300 = 30.0300 = 3.00 200 = 20400 = 4.00600 = 6.0001X = 10.0**

PP

Membrane

(M)

Nylon (N)Polypro Nano

Fiber (NP)

Nylon

Screen (NS)

PP Media

(P)PES (S)

Stainless

Steel Screen

(SS)

Polyester

Screen (TS)

010 = 0.1 005 = 0.05 005 = 0.5 100 = 10 003 = 0.3 004 = 0.04 018 = 18 200 = 20020 = 0.2 010 = 0.10 200 = 20 006 = 0.6 010 = 0.1 020 = 20 400 = 40

020 = 0.20 400 = 40 010 = 1.0 020 = 0.2 600 = 60045 = 0.45 600 = 60 030 = 3.0 045= 0.45 730 = 73065 = 0.65 10X = 100 050 = 5.0 065 = 0.65080 = 0.80 20X = 200 100 = 10.0 080 = 0.8120 = 1.20 200 = 20.0 120 =1.2

300 = 30.0500 = 50.0700 = 70.0

Leave pore

size blank

for Carbon

Fiber

** - Does not have DE

Pore size (Micron)

Pore size (Micron)

Page 5

Page 7: ZenPure - Q-Test

ZenPure ZenPure Capsule Size Options

Size-Nominal Disc Capsules Millimeters Inches Millimeters Inches Millimeters

D4 4mm .472" 12mm 0.005in2 0.03cm2

D13 13mm .63" 16mm  0.012in2 0.8cm2

D25 25mm 1.3" 33mm   0.713in2  4.6cm2

D40 40mm 1.79" 45.5mm 1.628in2 10.5cm2

D50/G50 50mm 2.13" 54mm   2.47in2 15.9cm2

D65 65mm  2.874" 73mm 4in2 26cm2

Inches (Nominal)

Millimeters (without fittings) Inches Millimeters Inches Millimeters

Junior Capsules 1.6" 41mm 1.6" 41mm 31in2 – 40.3in2 200cm2 - 260cm2

Depending on Media  Depending on Media 

MKL/MKP SeriesA 3.9" 60mm 2.32" 59mm 31in2 200cm2

B 3.9" 60mm 2.32" 59mm 46.5in2 300cm2

C 3.9" 60mm 2.32" 59mm 62in2 400cm2

D 3.9" 60mm 2.32" 59mm 77.5in2 500cm2

SKL/SKV SeriesH 1.5" 68mm 2.88" 73.2mm .775ft2 720cm2

S 2.5" 98mm 2.88" 73.2mm 1.48ft2 1380cm2

L 5" 153mm 2.88" 73.2mm 2.8ft2 2600cm2

E 7.5" 251mm 2.88" 73.2mm  4.3ft2 3980cm2

K 10" 281mm 2.88" 73.2mm  5.6ft2 5200cm2

ZenCapT-Line 10" 352mm 3.54" 90mmT-Line 20" 596mm 3.54" 90mmT-Line 30" 841mm 3.54" 90mmT-Line 40" 1086mm 3.54" 90mmIn-Line 10" 273mm 3.54" 90mmIn-Line 20" 518mm 3.54" 90mmIn-Line 30" 763mm 3.54" 90mmIn-Line 40" 1008mm 3.54" 90mm

Varies According to Media

Size-Diameter Filtration Area

Size - Length

Varies According to MediaVaries According to MediaVaries According to MediaVaries According to Media

Size - Diameter Filtration Area

Varies According to Media

Varies According to MediaVaries According to Media

Zen

Pu

re

Page 6

Page 8: ZenPure - Q-Test

ZenPure PureFlo® Filtration Discs

Zen

Pu

re

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company. Copyright 2003-2012 ZenPure or an affiliated company. All rights reserved.

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

A4 Rev 2011.08

PureFlo® Membrane Discs can be used for simple, quick, and efficient filtration of fluids and gases used in laboratory, pilot, and small-scale applications. These discs can be used for clarification of acids, bases and solvents. The same membrane is used in the larger PureFlo family of filters to allow for consis-tent scale-up of the product.

PureFlo® Membrane Discs are available in a variety of different materials and diameter sizes to meet your applications and test equipment requirements. They are available in pore sizes ranging from 0.05um to 200um.

PureFlo Membrane Discs Ordering Guide

Materials of Construction Membrane: Nylon, Nylon Screen Polyethylene, PES,

Polypropylene Membrane, Polypropylene Media, and Hydrophilic and phobic PTFE bonded on to Polypro-pylene support

Operating Conditions

Max. Differential Pressure: 30 psid (2 bar) Maximum Operating Pressure Liquid: 60 psig @ 77° F (4 Bar @ 25° C) Maximum Operating Pressure Gas: 30 psig @ 77° F (2 Bar @ 25° C) Maximum Operating Temperature: 60° C

Available Diameters (mm) - 13, 25, 47, 90, 142 Regulatory Compliance The discs are manufactured from materials

that conform to the requirements of 21CFR Part 177 of the U.S. Code of Federal Regula-tions. Nylon PES, PTFE, and PP Membrane are also in compliance with the USP Class VI Biological Test for Plastics.

Charged Nylon Depth PP* Polyethylene PTFE

( Hyd rophob ic)

Polypro Membrane Nylon Nylon

Screen*Polypro Media*

PTFE ( Hydro phi l ic)

PES

CN = Charged Nylon 013 = 13 005 = 0.05 002 = 0.2um 020 = 0.20 010 = 0.10 010 = 0.1 005 = 0.05 100 = 10 003 = 0.3 020 = 0.20 005 = 0.05 25DP = Depth PP 025 = 25* 010 = 0.10 005 = 0.5um 100 = 1.0 020 = 0.20 020 = 0.2 010 = 0.10 200 = 20 006 = 0.6 045 = 0.45 010 = 0.10 50E = Polyethylene 047 = 47 020 = 0.20 010 = 1.0um 150 = 1.5 045 = 0.45 020 = 0.20 400 = 40 010 = 1.0 100 = 1.0 020 = 0.20F = PTFE (Hydrophobic) 090 = 90 045 = 0.45 015 = 1.5um 250 = 2.5 100 = 1.0 045 = 0.45 600 = 60 030 = 3.0 300 = 3.0 045 = 0.45M = PP Membrane 142 = 142 065 = 0.65 025 = 2.5um 300 = 3.0 065 = 0.65 10X = 100 050 = 5.0 500 = 5.0 065 = 0.65N = Nylon 080 = 0.80 045 = 4.5um 500 = 5.0 080 = 0.80 20X = 200 100 = 10 080 = 0.80NS = Nylon Screen 120 = 1.20 100 = 10um 999 = 10 120 = 1.20 200 = 20 120 = 1.20P = PP Media 200 = 20um 300 = 30HF = PTFE (Hydrophilic) 400 = 40S = PES 500 = 50

700 = 7015X = 150

*Note: All PP Media, Depth PP and Nylon Screen only sold in packs of 25, and 25mm disks only sold in packs of 25*Note: All PP Media, Depth PP and Nylon Screen only sold in packs of 25, and 25mm disks only sold in packs of 25Example – A pack of 25 discs, 47mm, 1.0 M cron Nylon Membrane Disc is N-047-100-25

Quantity (per pack)

Pore Sizes (Micron)

Filter MediaFilter

Diameter (mm)

Page 7

Page 9: ZenPure - Q-Test

PureFlo® Filter Cup

(Table Top Filtration)

ZenPure Z

en

Pu

re

Vacuum Filter Cups

PureFlo® Filter Cups are a convenient, disposable unit for easy and high performance filtration of liquid solutions. Cups have a 175-mL capacity. Choose from 13 filter medias. Membranes are 63mm in diameter with a 31-cm2 filter area.

The filter cup is made of molded polypropylene with an integral thermally-bonded filter. Ideal for sterilizing tis-sue culture media, buffers, weak and dilute acids, and bases, and alcohols, or other solvent solutions. Consult chemical resistance charts before use.

The tapered cup and compact profile can be stacked for multiple and simultaneous filtration steps. The filter cups come stacked for easy and compact storage. For added protection against contamination, the cup has a bottom lip to prevent the bottom support grid from accidently touching working surfaces.

Order a filter funnel base to use the cup with vacuum pressure to speed the filtration process along. Bases easily attach to standard laboratory flasks with stopper sizes 5 through 8 available to fit standard size flask open-ings. The vacuum should be supplied gradually to 16”

Hg (7.8 PSI).

Glass Flask not included

Specifications Materials of Construction: Cup Material: PP (standard), Polyethylene , Gamma Stabilized PP, and Nylon Membrane: 12 options (See ordering guide) Fitting Connections: Vacuum Inlet: 3/8” Hose Barb Vacuum Inlet or none Stopper Sizes : 5,6,7,8 Nominal Dimensions: Diameter: 79mm Capacity: 175-mL Effective Filtration Area: 63mm in diameter, 31cm2 filter area Available Ratings: 0.05– 150um (See ordering guide Operating Conditions: Maximum Operational pressure: 16” Hg (7.8 PSI) (No Reverse direction) Maximum Operating Temperature: PP & Gamma PP 80°C/176°F, HDPE 60°C/140°F Autoclavable & Sanitizable: Cups can be autoclaved 1 time at 123°C for 60 minutes or chemically sanitized by soaking common sanitizing agents or hot water at 80°C (no reverse pressure should be applied).

Regulatory Compliance: The cups are constructed with polypropylene resins and filtration media in compliance with 21CFR Part 177 of the US Code of Federal Regulations and USP Class VI Biological Test for Plastics.

Applications Pharmaceutical Products Analysis

Combinatorial Chemistry

Sample and Small Batch Clarification and Filtra-tion

Sample and Small Batch Preparation and Clean-Up

Purification and Concen-tration

Filtration of Aqueous and Organic Solutions

Environmental Monitor-ing and Analysis

Sterile Filtration

Laboratory Food and Beverage

Page 8

Page 10: ZenPure - Q-Test

ZenPure PureFlo® Filter Cup

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

A5.5 Rev 2011.07

PureFlo Filter Cup Ordering Guide

CN = Charged Nylon A = 175mlE = PolyethyleneF = PTFE E = Polyethylene G =Glass FiberHF = Hydrophil c PTFEM = PP Membrane N = Nylon N = NylonNP = PP Nano FiberNS = Nylon ScreenP = PP MediaS = PES

TS = Polyester Screen

P = Polypropylene (standard)

FC = Filter Cup

Example – 25 Filter Cups with 1.0 Micron PTFE Filter Membrane, 175ml size Cup, PP material would be FCF100AP

GP = Gamma stabilized PP

Blank = 25ea/Box

PureFlo Filter

Cup

-6-ETO = Indiv dually bagged Ethylene ox de sterilization (6 /box)

Pore Sizes

(Micron)

Pick From Pore

Size Table

Filter Media

SS = Stainless Steel Screen

Cup Size Cup Material Options

-12 = Individually bagged (12 /box)

Charged

Nylon (CN)

Polyethylen

e (E)

Glass

Fiber (G)

Hydrophobic

PTFE (HF)

Hydrophilic

PTFE (F)

Polypro

Membrane

(M)

Nylon (N)PP Nano

Fiber (NP)

Nylon

Screen

(NS)

Polypro

Media (P)PES (S)

Stainless

Steel

Screen (SS)

Polyester

Screen

(TS)

005 = 0.05 020 = 0.20 004 = 0.45 010 = 0.10 010 = 0.10 010 = 0.1 005 = 0.05 005 = 0.5 100 = 10 003 = 0.3 005 = 0.05 018 = 18 300 = 30010 = 0.10 100 = 1.0 005 = 0 5 020 = 0.20 020 = 0.20 020 = 0.2 010 = 0.10 200 = 20 006 = 0.6 010 = 0.10 020 = 20 730 = 73020 = 0.20 150 = 1.5 010 = 1 0 045 = 0.45 020 = 0.20 400 = 40 010 = 1.0 020 = 0.20045 = 0.45 250 = 2.5 030 = 3 0 100 = 1.0 045 = 0.45 600 = 60 030 = 3.0 045 = 0.45065 = 0.65 050 = 5 0 300 = 3.0 065 = 0.65 10X = 100 050 = 5.0 065 = 0.65080 = 0.80 100 = 10 500 = 5.0 080 = 0.80 20X = 200 100 = 10 080 = 0.80120 = 1.20 200 = 20 999 = 10 120 = 1.20 200 = 20 120 = 1.20

300 = 30 300 = 30400 = 40500 = 50700 = 7015X = 150

Pore Sizes (Micron)

0 = No StopperBP = Black PP 5 = Size 5

6 = Size 6 N = Buna N N = Buna N7 = Size 7 E = EPDM E = EPDM8 = Size 8 V = Viton V = Viton

E = Polyethylene

FS = Filter Cup Base

Stopper Size Stopper Materials O-Ring Materials

0 = Without hose barb

P = Polypropylene (standard) 0 = No O-ring

Base Type Cup Material

N = Nylon

GP = Gamma stabilized PP 1 = With hose barb

0 = No StopperS = Silicone (Standard) S = Silicone (Standard)

Example – Filter Cup base without hose barb, with PP material, Size 5 SIL stopper, SIL O-Ring would be FS0P5SS

Filter Cup

Base

PureFlo Filter Base Ordering Guide Filter Base Spare Parts

Size Material

5 = Size 5 S = Silicone (Standard)6 = Size 6 N = Buna N7 = Size 7 E = EPDM8 = Size 8 V = Viton

Example: FS-RS-5-S = Filter cup base rubber stopper, Silicone materialFS-OR = for O-Ring on the Stem

= for rubber stopper

Filter Cup Base Spart Part Order

Type

Example: FS-OR-S = Filter cup base O-Rings, Silicone material

FS-RS

Size 5: 23mm at bottom/26mm at topSize 6: 26mm at bottom/32mm at topSize 7: 30mm at bottom/37mm at topSize 8: 33mm at bottom/40mm at top

Stopper Sizes

Page 9

Page 11: ZenPure - Q-Test

ZenPure PureFlo® D4 Filter Capsules

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

A5.9 Rev 2011.08

PureFlo® D4 Filter Capsules have been designed for simple, quick, and efficient filtration of fluids used in laboratory and analytical small-scale applications. Ten different media options can be placed in an all-polypropylene construction for excellent chemical compatibility. The small compact design of the filter capsule also reduces hold-up volume and exposure to hazardous liquids. No adhesives, binders, or surfactants are used in the manufacturing process. The filters are thermally sealed to insure integrity.

Charged

Nylon

(CN)

Polyethylene

(E)PTFE (F)

Glass

Fiber (G)

Polypro

Membrane

(M)

Nylon (N)

Nylon

Screen

(NS)

Polypro

Media (P)PES (S)

CN = Charged Nylon 005= 0.05 020 = 0.20 010 = 0.10 004 = 0.45 010 = 0.1 005= 0 05 100 = 10 003 = 0.3 005 = 0.05 -1 = Single BaggedE = Polyethylene 010 = 0.10 100 = 1.0 020 = 0 20 005 = 0.5 020 = 0 2 010 = 0.10 200 = 20 006 = 0.6 010 = 0.10F = PTFE 020 = 0 20 150 = 1.5 045 = 0.45 010 = 1.0 020 = 0.20 400 = 40 010 = 1.0 020 = 0.20G = Glass Fiber 045 = 0.45 250 = 2.5 100 = 1 0 030 = 3.0 045 = 0.45 600 = 60 030 = 3.0 045 = 0.45M = PP Membrane 065 = 0 65 300 = 3 0 050 = 5.0 065 = 0.65 10X = 100 050 = 5.0 065 = 0.65N = Nylon 080 = 0 80 500 = 5 0 100 = 10 080 = 0.80 20X = 200 100 = 10 080 = 0.80NP = PP Nano Fiber 120 = 1 20 999 = 10 200 = 20 120 = 1.20 200 = 20 120 = 1.20 -NY = Nylon ShellNS = Nylon Screen 300 = 30 300 = 30 -V = PVC ShellP = PP Media 200 = 20 400 = 40S = PES 400 = 40 500 = 50

600 = 60 005 = 0.5 700 = 70730 = 73 15X = 150

Polypro

Nano

Fiber (NP)

TS = Polyester Screen

Options

LF = Luer Lock Female

Other options are

possible please inquire

PureFlo D4

Filter

Capsules

Filter Media

Pore Sizes (Micron)

Inlet

Fitting

Outlet

Fitting

-GP = Gamma stable Polypropylene Shell

Example – 1 0 Micron Nylon Filter Media with Luer Lock by Male Luer Lock fittings would be D4N100LFLM

D4 = 4mm Disc Filter

LF = Luer Lock Female

LM = Luer Lock Male -E = Polyethylene

Shell (for Gamma Stability)

LM = Luer Lock Male

Polyester

Screen (TS)

-ETO = E hylene Ox de

Sterilization

PureFlo D4 Filter Capsules Ordering Guide

Materials of Construction Membrane: Nylon, Nylon Screen Polyethylene, PES,

Polypropylene Membrane, Polypropylene Media, and PTFE

Operating Conditions Max. Working Pressure: PP/HDPE/PVC 80 PSID @ 77°F/25°C (5.5 bar)

Gamma PP 45 PSID @ 77°F/25°C (3.1 bar) Minimum Burst pressure: PP/HDPE: 120 PSID @ 77° F/25°C (8.3 bar) Gamma PP: 60 PSID @ 77°F/25°C (4.1 bar) Maximum forward differential pressure: 60 PSID (4.1 bar) at 68°F (20°C) Maximum reverse differential pressure:

29 PSIG (2 bar) at 68°F (20°C) Maximum Operating Temperature: PP & Gamma PP: 176°F/80°C HDPE: 140°F/60°C PVC: 122°F/50°C

Fitting Connections Male & Female Luer Lock Effective Filtration Area - 0.005in2 (0.03 cm2) Autoclave Cycles - 10 times @ 257°F/125°C for 30

minutes. Capsules must not be in situ steam-sterilized

Regulatory Compliance The discs are manufactured from materials that

conform to the requirements of 21CFR Part 177 of the U.S. Code of Federal Regulations. Medias and Membranes are also in compliance with the USP Class VI Biological Test for Plastics. (Except Blk PP and PVC.)

12

2

Page 10

Page 12: ZenPure - Q-Test

ZenPure PureFlo® D13R Filter Capsules

Zen

Pu

re

Your Local Distributor:

A6 Rev 2011.08

ZenPure

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company. Copyright 2003-2012 ZenPure or an affiliated company. All rights reserved.

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

PureFlo® D13R Filter Capsules have been designed for simple, quick, and efficient filtration of fluids used in laboratory and analytical small-scale applications. Eight different media options can be placed in an all-polypropylene construction for excellent chemical compatibility. The small compact design of the filter capsule also reduces hold-up volume and exposure to hazardous liquids. No adhesives, binders, or surfactants are used in the manufacturing process. The filters are thermally sealed using an overmold process to insure integrity and higher pressures.

Charged Nylon (CN)

Polyethylene (E) PTFE (F) Glass

Fiber (G)

Polypro Membrane

(M)Nylon (N)

Nylon Screen

(NS)

Polypro Media (P) PES (S)

CN = Charged Nylon 005= 0.05 020 = 0.20 010 = 0.10 004 = 0.45 010 = 0.1 005= 0.05 100 = 10 003 = 0 3 005 = 0.05 -1 = Single BaggedE = Polyethylene 010 = 0.10 100 = 1.0 020 = 0.20 005 = 0 5 020 = 0 2 010 = 0.10 200 = 20 006 = 0 6 010 = 0.10F = PTFE 020 = 0.20 150 = 1.5 045 = 0.45 010 = 1 0 020 = 0.20 400 = 40 010 = 1 0 020 = 0.20G = Glass Fiber 045 = 0.45 250 = 2.5 100 = 1.0 030 = 3 0 045 = 0.45 600 = 60 030 = 3 0 045 = 0.45M = PP Membrane 065 = 0.65 300 = 3.0 050 = 5 0 065 = 0.65 10X = 100 050 = 5 0 065 = 0.65N = Nylon 080 = 0.80 500 = 5.0 100 = 10 080 = 0.80 20X = 200 100 = 10 080 = 0.80

NS = Nylon Screen 120 = 1.20 999 = 10 200 = 20 120 = 1.20 200 = 20 120 = 1.20 -NY = Nylon ShellP = PP Media 300 = 30 300 = 30 -V = PVC ShellS = PES 200 = 20 400 = 40 LM = Luer Lock LM = Luer Lock

400 = 40 500 = 50600 = 60 700 = 70730 = 73 15X = 150

Polyester Screen (TS)

TS = Polyester Screen

-GP = Gamma stable Polypropylene Shell

1Q = 1/8" Male Quick Coupling

LF = Luer Lock Female

LF = Luer Lock Female

1Q = 1/8" Male Quick Coupling

Example – 1.0 Micron Nylon Filter Media with Luer Lock by luer Slip fittings would be D13RN100LFLS

LS = Luer Lock Male Slip

LS = Luer Lock Male Slip

-ETO = Ethylene Oxide Ster lization

Inlet Fitting

1H = 1/8" Hose Barb

1H = 1/8" Hose Barb

PureFlo D13R Filter Capsules Filter Media

D13R = 13mm

Options

-E = Polyethylene Shell (for Gamma Stability)

0H = 1/16" Hose Barb

Pore Sizes (Micron)

Outlet Fitting

0H = 1/16" Hose Barb

PureFlo D13R Filter Capsules Ordering Guide

Materials of Construction Membrane: Nylon, Nylon Screen Polyethylene, PES,

Polypropylene Membrane, Polypropylene Media, and Hydrophilic PTFE

Fitting Connections Male & Female Luer Lock, Luer Slip, 1/16” & 1/8” Hose

barb

Effective Filtration Area - 0.124in2 (0.8 cm2)

Autoclave Cycles - 10 times @ 257°F/125°C for 30 minutes Capsules must not be in situ steam-sterilized

Operating Conditions Max. Working Pressure: PP/HDPE/PVC 80 PSID @ 77°F/25°C (5.5 bar)

Gamma PP 45 PSID @ 77°F/25°C (3.1 bar) Minimum burst pressure: PP/HDPE: 120 PSID @ 77° F/25°C (8.3 bar) Gamma PP: 60 PSID @ 77°F/25°C (4.1 bar) Maximum forward differential pressure: 60 PSID (4.1 bar) at 68°F (20°C) Maximum reverse differential pressure: 29 PSIG (2 bar) at 68°F (20°C) Maximum Operating Temperature: PP & Gamma PP: 176°F/80°C HDPE: 140°F/60°C PVC: 122°F/50°C

Regulatory Compliance The discs are manufactured from materials that con-form to the requirements of 21CFR Part 177 of the U.S. Code of Federal Regulations. Medias and Mem-branes are also in compliance with the USP Class VI Biological Test for Plastics. (Except Blk PP and PVC.)

16

7.

3

D13R-0H0H D13R-1H1H D13R-1Q1Q D13R-LFLF D13R-LMLM D13R-LSLS

Page 11

Page 13: ZenPure - Q-Test

ZenPure PureFlo® D13U Filter Capsules

Zen

Pu

re

Your Local Distributor:

A6.1 Rev 2011.08

ZenPure

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

PureFlo® D13U Filter Capsules have been designed for simple, quick, and efficient filtration of fluids used in laboratory and analytical small-scale applications. Nine different media options can be placed in an all-polypropylene construction for excellent chemical compatibility. The small compact design of the filter capsule also reduces hold-up volume and exposure to hazardous liquids. No adhesives, binders, or surfactants are used in the manufacturing process. The filters are ultrasonically sealed to insure integ-rity. It is an excellent low cost option for low pres-sure applications.

Charged

Nylon

(CN)

Polyethylene

(E)PTFE (F)

Glass

Fiber (G)

Polypro

Membrane

(M)

Nylon (N)

Nylon

Screen

(NS)

Polypro

Media (P)PES (S)

CN = Charged Nylon 005= 0.05 020 = 0.20 010 = 0.10 004 = 0.45 010 = 0.1 005= 0.05 100 = 10 003 = 0 3 005 = 0.05 -1 = Single BaggedE = Polyethylene 010 = 0.10 100 = 1.0 020 = 0.20 005 = 0 5 020 = 0 2 010 = 0.10 200 = 20 006 = 0 6 010 = 0.10F = PTFE 020 = 0.20 150 = 1.5 045 = 0.45 010 = 1 0 020 = 0.20 400 = 40 010 = 1 0 020 = 0.20G = Glass Fiber 045 = 0.45 250 = 2.5 100 = 1.0 030 = 3 0 045 = 0.45 600 = 60 030 = 3 0 045 = 0.45M = PP Membrane 065 = 0.65 300 = 3.0 050 = 5 0 065 = 0.65 10X = 100 050 = 5 0 065 = 0.65

N = Nylon 080 = 0.80 500 = 5.0 100 = 10 080 = 0.80 20X = 200 100 = 10 080 = 0.80NS = Nylon Screen 120 = 1.20 999 = 10 200 = 20 120 = 1.20 200 = 20 120 = 1.20 -NY = Nylon ShellP = PP Media 300 = 30 200 = 20 300 = 30 -V = PVC ShellS = PES 400 = 40 400 = 40 LM = Luer Lock

M lLM = Luer Lock M l600 = 60 500 = 50

730 = 73 700 = 7015X = 150

Polyester

Screen (TS)

TS = Polyester Screen

Example – 1.0 Micron Nylon Filter Media with Luer Lock by luer Slip fittings would be D13UN100LFLS

1Q = 1/8" Male Quick Coupling

1Q = 1/8" Male Quick Coupling

-GP = Gamma stable Polypropylene Shell

PureFlo D13U

Filter CapsulesFilter Media

Pore Sizes (Micron)

Inlet Fitting Outlet Fitting

D13U = 13mm 0H = 1/16" Hose Barb

0H = 1/16" Hose Barb

1H = 1/8" Hose Barb

1H = 1/8" Hose Barb

Options

LS = Luer Lock Male Slip

LS = Luer Lock Male Slip

LF = Luer Lock Female

LF = Luer Lock Female

-ETO = Ethylene Oxide

Sterilization

-E = Polyethylene Shell (for Gamma Stability)

PureFlo D13U Filter Capsules Ordering Guide

Materials of Construction Membrane: Nylon, Nylon Screen Polyethylene, PES,

Polypropylene Membrane, Polypropylene Media, and Hydrophilic PTFE

Fitting Connections - Male & Female Luer Lock, Luer Slip, 1/16” & 1/8” Hose barb

Effective Filtration Area - 0.124in2 (0.8 cm2)

Autoclave Cycles - 3 times @ 257°F/125°C for 30 min-utes. Capsules must not be in situ steam-sterilized

Regulatory Compliance The discs are manufactured from materials that con-

form to the requirements of 21CFR Part 177 of the U.S. Code of Federal Regulations. Medias and Mem-branes are also in compliance with the USP Class VI Biological Test for Plastics. (Except Blk PP and PVC.)

16.5

A

5.

4

D13U-0H0H D13U-1H1H D13U-1Q1Q D13U-LFLF D13U-LMLM D13U-LSLS

Liquid:  30 psi (2.1 bar) 30 psi (2.1 bar) 45 psi  (3.1 bar) 60 psi (4.1 bar)Gas: 30 psi (2.1 bar) 30 psi (2.1 bar) 30psi  (2.1 bar) 44 psi (3.0 bar)

45 psi (3.1 bar) 45 psi (3.1 bar) 60 psi (4.1bar) 80 psi (5.5 bar)176°F (80°C) 176°F (80°C) 140°F (70°C) 122°F (50°C)

30 psid (2.1 bar) 30 psid (2.1 bar) 30 psid (2.1 bar) 44 psid (3.0 bar)30 psid (2.1 bar) 30 psid (2.1 bar) 30 psid (2.1 bar) 30 psid (2.1 bar)

45 kGy 45 kGy

PP ShellGamma Stablized

PP Shell HDPE Shell PVC Shell

Maximum working pressure

Minimum burst pressure:Maximum working temp:

Maximum forward differential pressure: Maximum reverse differential pressure:

Maximum gamma irradiation resistance:

Operating Conditions

Page 12

Page 14: ZenPure - Q-Test

ZenPure PureFlo® D25C Filter Capsules

Zen

Pu

re

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

A7 Rev 2011.08

PureFlo® D25C Filter Capsules (25mm diameter) have been designed for simple, quick, and efficient filtration of fluids and gases used in laboratory, pilot, and small scale applications. Eight different media options can be placed in an all-polypropylene construction for excellent chemical compatibility with 10 different fittings. The small compact design of the filter capsule also reduces hold-up volume and exposure to hazardous chemicals. No adhesives, binders, or surfactants are used in the manufacturing process. The unit is thermally-sealed to ensure integrity. Materials of Construction

Membrane: Nylon, Nylon Screen Polyethylene, PES, Polypropylene Membrane, Polypropylene Media, and Hydrophobic PTFE

Membrane Supports: Polypropylene Capsule Body: Polypropylene

Fitting Connections Luer Lock, Luer Slip, Hose Barb, Compression , NPT,

Quick Coupling Effective Filtration Area - 0.7in2 (4.6 cm2) Autoclave Cycles - 10 times @ 257°F/125°C for 30 minutes

Capsules must not be in situ steam-sterilized

PureFlo D25C Filter Capsules Ordering Guide

Charged

Nylon (CN)

Polyethylene

(E)PTFE (F)

Glass

Fiber (G)

Polypro

Membrane

(M)

Nylon (N)

Nylon

Screen

(NS)

Polypro

Media (P)PES (S)

Stainless

Steel

Screen

(SS)

Polyester

Screen

(TS)

005= 0.05 020 = 0.20 010 = 0.10 005 = 0.5 010 = 0.1 005= 0.05 100 = 10 003 = 0.3 005 = 0.05 018 = 18 200 = 20 0H = 1/16-3/32" Hose Barb 0H = 1/16-3/32" Hose Barb Blank = Polypropylene010 = 0.10 100 = 1.0 020 = 0.20 010 = 1.0 020 = 0.2 010 = 0.10 200 = 20 006 = 0.6 010 = 0.10 020 = 20 400 = 40 1C = 1/8" Compression 1C = 1/8" Compression -1 = Single Bagged

E = Polyethylene 020 = 0.20 150 = 1.5 045 = 0.45 030 = 3.0 020 = 0.20 400 = 40 010 = 1.0 020 = 0.20 600 = 60 1H = 1/8-3/16" Hose Barb 1H = 1/8-3/16" Hose BarbF = PTFE 045 = 0.45 250 = 2.5 100 = 1.0 050 = 5.0 045 = 0.45 600 = 60 030 = 3.0 045 = 0.45 730 = 73 1N = 1/8" NPTM 1N = 1/8" NPTMG = Glass Fiber 065 = 0.65 300 = 3.0 100 = 10 065 = 0.65 10X = 100 050 = 5.0 065 = 0.65 -BLK = Black PP shellM = PP Membrane 080 = 0.80 500 = 5.0 200 = 20 080 = 0.80 20X = 200 100 = 10 080 = 0.80N = Nylon 120 = 1.20 999 = 10 300 = 30 120 = 1.20 200 = 20 120 = 1.20 2H = 3/16-1/4" Hose Barb 2H = 3/16-1/4" Hose BarbNS = Nylon Screen 300 = 30 2UF = 1/4-28 thread Female 2UF = 1/4-28 thread Female -NY = Nylon ShellP = PP Media 400 = 40 3H = 1/4-3/8" Hose Barb 3H = 1/4-3/8" Hose Barb -V = PVC ShellS = PES 500 = 50 LF = Luer Lock Female LF = Luer Lock Female

700 = 70 LM = Luer Lock Male LM = Luer Lock Male10X = 100 LS = Luer Lock Male Slip LS = Luer Lock Male Slip O-Ring for Quick Connect

15X = 150

-OE = O-ring EPDM-ON = O-ring Nitrile-OV = O-ring Viton

Inlet Fitting Outlet Fitting Options

-E = Polyethylene Shell (for Gamma Stability)

-ETO = Ethylene Oxide Sterilization

1Q = 1/8" Male Quick Coupling

CN= Charged Nylon

D25C = 25mm Capsule filter

Blank = O-ring Silicon (Standard)

TS = Polyester Screen

1Q = 1/8" Male Quick Coupling

SS = Stainless Steel Screen

PureFlo D25C

Capsule

Filters

Filter Media

Pore Sizes (Micron)

Example – 1.0 Micron Nylon Filter Media with 1/4-3/8" hose barb fitting inlet and outlet would be D25CN1003H3H

-GP = Gamma stable Polypropylene Shell

Operating Conditions Max. Working Pressure: PP/HDPE/PVC 80 PSID @ 77°F/25°C (5.5 bar) Gamma PP 45 PSID @ 77°F/25°C (3.1 bar) Minimum burst pressure: PP/HDPE 120 PSID @ 77°F/25°C (8.3 bar) Gamma PP 60 PSID @ 77°F/25°C (4.1 bar) Maximum forward differential pressure: 60 PSID (4.1 bar) at 68°F (20° C) Maximum reverse differential pressure: 30 PSID (2.1 bar) at 68°F (20° C) Maximum Operating Temperature: PP & Gamma PP: 176°F/80°C HDPE: 140°F/60°C PVC: 122°F/50°C

Regulatory Compliance The discs are manufactured from materials that conform to the require-

ments of 21CFR Part 177 of the U.S. Code of Federal Regulations. Medias and Membranes are also in compliance with the USP Class VI Biological Test for Plastics. (Except Blk PP and PVC)

33

1.5A

1Q0H 1H 2H 3H

LFLS LFLM21N LS

LFLM

D25C-×-×××-1C

Page 13

Page 15: ZenPure - Q-Test

ZenPure PureFlo® D25U Filter Capsules

Zen

Pu

re

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

A7.2 Rev 2011.08

PureFlo® D25U Filter Capsules (25mm diameter) have been designed for simple, quick, and efficient filtration of fluids and gases used in laboratory, pilot, and small scale applications. Ten different media options can be placed in an all-polypropylene construction for excellent chemical compatibility with 11 different fittings. The small compact design of the filter capsule also reduces hold-up volume and exposure to hazard-ous chemicals. No adhesives, binders, or surfactants are used in the manufacturing process. The unit is ultrasonically-

sealed to ensure integrity.

Materials of Construction Membrane: Nylon, Nylon Screen Polyethylene, PES, Polypro-

pylene Membrane, Polypropylene Media, and Hydrophobic PTFE, Glass Fiber, Polyester Screen, SS Screen

Membrane Supports: Polypropylene Capsule Body: PP, Nylon, PVC, PE

Fitting Connections - Luer Lock, Luer Slip, Hose Barb, Compres-sion, NPT, Quick Coupling

Autoclave Cycles - 3 times @ 257°F/125°C for 30 minutes Capsules must not be in situ steam-sterilized

Effective Filtration Area - 0.7in2 (4.6 cm2)

PureFlo D25U Filter Capsules Ordering Guide

Charged

Nylon (CN)

Polyethylene

(E)PTFE (F)

Glass

Fiber (G)

Polypro

Membrane

(M)

Nylon (N)

Nylon

Screen

(NS)

Polypro

Media (P)PES (S)

Stainless

Steel

Screen

(SS)

Polyester

Screen

(TS)

005= 0.05 020 = 0.20 010 = 0.10 005 = 0.5 010 = 0.1 005= 0.05 100 = 10 003 = 0.3 005 = 0.05 018 = 18 200 = 20 0H = 1/16-3/32" Hose Barb 0H = 1/16-3/32" Hose Barb Blank = Poly propylene

010 = 0.10 100 = 1.0 020 = 0.20 010 = 1.0 020 = 0.2 010 = 0.10 200 = 20 006 = 0.6 010 = 0.10 020 = 20 400 = 40 1C = 1/8" Compression 1C = 1/8" Compression -1 = Single Bagged

E = Polyethylene 020 = 0.20 150 = 1.5 045 = 0.45 030 = 3.0 020 = 0.20 400 = 40 010 = 1.0 020 = 0.20 600 = 60 1H = 1/8-3/16" Hose Barb 1H = 1/8-3/16" Hose BarbF = PTFE 045 = 0.45 250 = 2.5 100 = 1.0 050 = 5.0 045 = 0.45 600 = 60 030 = 3.0 045 = 0.45 730 = 73 1N = 1/8" NPTM 1N = 1/8" NPTMG = Glass Fiber 065 = 0.65 300 = 3.0 100 = 10 065 = 0.65 10X = 100 050 = 5.0 065 = 0.65M = PP Membrane 080 = 0.80 500 = 5.0 200 = 20 080 = 0.80 20X = 200 100 = 10 080 = 0.80N = Nylon 120 = 1.20 999 = 10 300 = 30 120 = 1.20 200 = 20 120 = 1.20 2H = 3/16-1/4" Hose Barb 2H = 3/16-1/4" Hose Barb -BLK = Black PP shellNS = Nylon Screen 300 = 30 2UF = 1/4-28 thread Female 2UF = 1/4-28 thread FemaleP = PP Media 400 = 40 3H = 1/4-3/8" Hose Barb 3H = 1/4-3/8" Hose BarbS = PES 500 = 50 LF = Luer Lock Female LF = Luer Lock Female -V = PVC Shell

700 = 70 LM = Luer Lock Male LM = Luer Lock Male10X = 100 LS = Luer Lock Male Slip LS = Luer Lock Male Slip15X = 150 -OE = O-ring EPDM

-ON = O-ring Nitrile-OV = O-ring VitonBlank = O-ring Silicon

Pore Sizes (Micron)

Example – 1.0 Micron Nylon Filter Media with 1/4-3/8" hose barb fitting nlet and outlet would be D25UN1003H3H

-E = Polyethylene Shell (for Gamma Stability)

-GP = Gamma stable Polypropylene Shell

-ETO = Ethylene Oxide Sterilization

O-ring for Quick

Coupling

PureFlo D25U

Capsule

Filters

Filter Media

D25U = 25mm Capsule filter

1Q = 1/8" Male Quick Coupling

1Q = 1/8" Male Quick Coupling

CN = Charged Nylon

SS = Stainless Steel Screen

TS = Polyester Screen

Inlet Fitting Outlet Fitting Options

Regulatory Compliance The discs are manufactured from materials that con-

form to the requirements of 21CFR Part 177 of the U.S. Code of Federal Regulations. Medias and Mem-branes are also in compliance with the USP Class VI Biological Test for Plastics. (Except Blk PP and PVC.)

1H1H LFLF LF1Q LFLM LSLS LMLM1Q1Q

0H0H 2H2H 3H3H

1C1C 1N1N 2UF2UF

Liquid:  30 psi (2.1 bar) 30 psi (2.1 bar) 45 psi  (3.1 bar) 60 psi (4.1 bar)Gas: 30 psi (2.1 bar) 30 psi (2.1 bar) 30psi  (2.1 bar) 44 psi (3.0 bar)

45 psi (3.1 bar) 45 psi (3.1 bar) 60 psi (4.1bar) 80 psi (5.5 bar)176°F (80°C) 176°F (80°C) 140°F (70°C) 122°F (50°C)

30 psid (2.1 bar) 30 psid (2.1 bar) 30 psid (2.1 bar) 44 psid (3.0 bar)30 psid (2.1 bar) 30 psid (2.1 bar) 30 psid (2.1 bar) 30 psid (2.1 bar)

45 kGy 45 kGy

Gamma Stablized PP Shell

Maximum reverse differential pressure:Maximum gamma irradiation resistance:

Operating ConditionsHDPE Shell PVC Shell

Maximum working pressure @ 77°F/25°C:Minimum burst pressure @ 77°F/25°C:

Maximum working temp: Maximum forward differential pressure :

PP Shell

Page 14

Page 16: ZenPure - Q-Test

Your Local Distributor:

ZenPure

A7.7 Rev 2011.08

PureFlo® D40C Filter Capsule Z

en

Pu

re

ZenPure

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated

company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

Charged

Nylon (CN)

Polyethylene

(E)PTFE (F)

Glass

Fiber (G)

Polypro

Membrane

(M)

Nylon (N)

Nylon

Screen

(NS)

Polypro

Media (P)PES (S)

Stainless

Steel

Screen (SS)

005= 0.05 020 = 0.20 010 = 0.10 005 = 0.5 010 = 0.1 005= 0.05 100 = 10 003 = 0.3 005 = 0.05 018 = 18 0H = 1/16-3/32" Hose Barb 0H = 1/16-3/32" Hose Barb Blank = Poly propylene010 = 0.10 100 = 1.0 020 = 0.20 010 = 1.0 020 = 0.2 010 = 0.10 200 = 20 006 = 0.6 010 = 0.10 1C = 1/8" Compression 1C = 1/8" Compression -1 = Single Bagged

E = Polyethylene 020 = 0.20 150 = 1.5 045 = 0.45 030 = 3.0 020 = 0.20 400 = 40 010 = 1.0 020 = 0.20 1H = 1/8-3/16" Hose Barb 1H = 1/8-3/16" Hose BarbF = PTFE 045 = 0.45 250 = 2.5 100 = 1.0 050 = 5.0 045 = 0.45 600 = 60 030 = 3.0 045 = 0.45 1N = 1/8" NPTM 1N = 1/8" NPTMG = Glass Fiber 065 = 0.65 300 = 3.0 100 = 10 065 = 0.65 10X = 100 050 = 5.0 065 = 0.65 1Q = 1/8" Male Quick Coupling 1Q = 1/8" Male Quick Coupling -BLK = Black PP shellM = PP Membrane 080 = 0.80 500 = 5.0 200 = 20 080 = 0.80 20X = 200 100 = 10 080 = 0.80 200 = 20 2H = 3/16-1/4" Hose Barb 2H = 3/16-1/4" Hose BarbN = Nylon 120 = 1.20 999 = 10 300 = 30 120 = 1.20 200 = 20 120 = 1.20 400 = 40 2UF = 1/4-28 thread Female 2UF = 1/4-28 thread FemaleNS = Nylon Screen 300 = 30 600 = 60 3H = 1/4-3/8" Hose Barb 3H = 1/4-3/8" Hose Barb -NY = Nylon ShellP = PP Media 400 = 40 730 = 73 LF = Luer Lock Female LF = Luer Lock FemaleS = PES 500 = 50 LM = Luer Lock Male LM = Luer Lock Male

700 = 70 LS = Luer Lock Male Slip LS = Luer Lock Male Slip

-OE = O-ring EPDM-ON = O-ring Nitrile-OV = O-ring Viton

PureFlo

D40C Filter

Capsules

Filter Media

D40C = 40mm

Capsule filter

Example – 1.0 Micron Nylon Filter Media and Female Luer Lock fittings I/O would be D40CN100LFLF

-E = Polyethylene Shell (for Gamma Stability)

OptionsOutlet Fitting

-GP = Gamma stable Polypropylene Shell

Inlet Fitting

-ETO = Ethylene Oxide Sterilization

Blank = O-ring Silicon (Standard)

O-Ring for Quick

Coupling

Pore Sizes (Micron)

CN = Charged Nylon

Polyester

Screen (TS)

SS = Stainless Steel Screen

TS = Polyester Screen

40mm Disc Capsule filter

PureFlo® D40C Filter Capsules have been specially de-signed for simple, quick, and efficient filtration of fluids and gases used in laboratory, pilot, and small-scale ap-plications. Eleven different media options can be placed in an all-polypropylene construction for excel-lent chemical compatibility. The small compact design of the filter capsule reduces hold-up volume and expo-sure to hazardous chemicals. No adhesives, bind-ers, or surfactants are used in the manufacturing proc-ess. The unit is thermally-sealed to ensure integrity.

Effective Filtration Area - 10.5 cm2

Autoclave Cycles - 10 times @ 257°F/125°C for 30 minutes Capsules must not be in situ steam-sterilized

Regulatory Compliance The discs are manufactured from materials that conform

to the requirements of 21CFR Part 177 of the U.S. Code of Federal Regulations. Medias and Membranes are also in compliance with the USP Class VI Biological Test for Plas-tics. (Except Blk PP and PVC.)

PureFlo D40C Filter Capsules Ordering Guide

Specifications Materials of Construction

Membrane: PE, PTFE, GF, PP, Nylon, PES, SS Membrane Supports: Polypropylene Capsule Body: Polypropylene Fitting Connections: See Ordering Guide

Operating Conditions Max. Working Pressure: PP/HDPE/PVC 80 PSID @ 77°F/25°C (5.5 bar)

Gamma PP 45 PSID @ 77°F/25°C (3.1 bar) Minimum burst pressure: PP/HDPE: 120 PSID @ 77° F/25°C (8.3 bar) Gamma PP: 60 PSID @ 77°F/25°C (4.1 bar) Maximum forward differential pressure: 60 PSID (4.1 bar) at 68°F (20° C) Maximum reverse differential pressure: 30 PSID (2.1 bar) at 68°F (20° C) Maximum Operating Temperature: PP & Gamma PP: 176°F/80°C HDPE: 140°F/60°C PVC: 122°F/50°C

8

45.5D40C-×-×××-0H0H D40C-×-×××-1H1H D40C-×-×××-2H2H D40C-×-×××-3H3H D40C-×-×××-LFLF

D40C-×-×××-LSLSD40C-×-×××-1C1C D40C-×-×××-1N1N D40C-×-×××-1Q1Q

Dimensions and

Fittings

Page 15

Page 17: ZenPure - Q-Test

ZenPure PureFlo® D50C Filter Capsules

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

A8 Rev 2011.08

PureFlo® D50C Filter Capsules (50mm diameter) have been spe-cially designed for simple, quick, and efficient filtration of liquids and gases used in laboratory, pilot, and small-scale applications. Nine different media options with ten fitting options can be placed in an all-polypropylene or polyethylene shell construction for excellent chemical compatibility. The small, compact design of the filter capsule also reduces hold-up volume and exposure to hazardous chemicals. No adhesives, binders, or surfactants are used in the manufacturing process. The unit is thermally-sealed to ensure integrity.

Materials of Construction Membrane: Nylon, Nylon Screen, Polyethylene, PES, Polypropylene Membrane, Polypropylene Media, Hydrophobic and Hydrophilic PTFE Membrane Supports: Polypropylene Capsule Body: Polypropylene (standard)

Fitting Connections Luer Lock, Luer Slip, Hose Barb, Compression, NPT,

Quick Couplings Effective Filtration Area - 2.5in2 (15.9 cm2) Autoclave Cycles - 10 times @ 257°F/125°C for 30 minutes

Capsules must not be in situ steam-sterilized

Operating Conditions Max. Working Pressure: PP/HDPE/PVC 80 PSID @ 77°F/25°C (5.5 bar)

Gamma PP 45 PSID @ 77°F/25°C (3.1 bar) Minimum burst pressure: PP/HDPE: 120 PSID @ 77° F/25°C (8.3 bar) Gamma PP: 60 PSID @ 77°F/25°C (4.1 bar) Maximum forward differential pressure: 60 PSID (4.1 bar) at 68°F (20°C) Maximum reverse differential pressure: 30 PSID (2.1 bar) at 68°F (20°C) Maximum Operating Temperature: PP & Gamma PP: 176°F/80°C HDPE: 140°F/60°C PVC: 122°F/50°C

PureFlo D50C Filter Capsules Ordering Guide

1QLF 1Q1QF

2H3TLF

2NF1H

54

8

2C

2H 1N 1NF 2N

Charged

Nylon (CN)

Polyethylene

(E)PTFE (F)

Glass

Fiber (G)

Polypro

Membrane

(M)

Nylon (N)

Nylon

Screen

(NS)

Polypro

Media (P)PES (S)

005= 0.05 020 = 0.20 010 = 0.10 005 = 0.5 010 = 0.1 005= 0.05 100 = 10 003 = 0.3 005 = 0.05 1N = 1/8" MNPT 1N = 1/8" MNPT

010 = 0.10 100 = 1.0 020 = 0.20 010 = 1.0 020 = 0.2 010 = 0.10 200 = 20 006 = 0.6 010 = 0.10 1NF = 1/8" FNPT 1NF = 1/8" FNPT

E = Polyethylene 020 = 0.20 150 = 1.5 045 = 0.45 030 = 3.0 020 = 0.20 400 = 40 010 = 1.0 020 = 0.20 1H = 1/8"-1/4"Hose Barb 1H = 1/8"-1/4"Hose BarbF = PTFE 045 = 0.45 250 = 2.5 100 = 1.0 050 = 5.0 045 = 0.45 600 = 60 030 = 3.0 045 = 0.45G = Glass Fiber 065 = 0.65 300 = 3.0 100 = 10 065 = 0.65 10X = 100 050 = 5.0 065 = 0.65M = PP Membrane 080 = 0.80 500 = 5.0 200 = 20 080 = 0.80 20X = 200 100 = 10 080 = 0.80N = Nylon 120 = 1.20 999 = 10 300 = 30 120 = 1.20 200 = 20 120 = 1.20 -NY = Nylon ShellNS = Nylon Screen 300 = 30 2C = 1/4" Compression 2C = 1/4" Compression -1 = Single BaggedP = PP Media 400 = 40 2H = 1/4"-3/8" Hose Barb 2H = 1/4"-3/8" Hose BarbS = PES 500 = 50 2N = 1/4" MNPT 2N = 1/4" MNPT

200 = 20 700 = 70 2NF = 1/4" FNPT 2NF = 1/4" FNPT -BLK = Black PP shell400 = 40 15X = 150600 = 60730 = 73 LF = Luer Lock Female LF = Luer Lock Female -OE = O-ring EPDM

-ON = O-ring Nitrile-OV = O-ring Viton

CN = Charged Nylon

Options

PureFlo

D50C

Capsule

Filters

Example – 1.0 Micron Nylon Filter Media with 1/4" hose barb fittings would be D50CN1002H2H

1Q = 1/8" Male Quick Coupling

1QF = 1/8" Female Quick Coupling

Filter Media

Pore Sizes (Micron)

D50C = 50mm

Capsule filter

Blank = Polypropylene Shell

1QF = 1/8" Female Quick Coupling

Input Fitting

-ETO = Ethylene Oxide Sterilization

Output Fitting

1Q = 1/8" Male Quick Coupling

-E = Polyethylene Shell (for Gamma Stability)

-GP = Gamma stable Polypropylene Shell

O-Ring for Quick

Coupling

Blank = O-ring Silicon (Standard)

Polyester

Screen (TS)

TS = Polyester Screen 2Q = 1/4" Male Quick

Coupling for Metal latch2Q = 1/4" Male Quick Coupling for Metal latch

Regulatory Compliance The discs are manufactured from materials that conform to the requirements of 21CFR Part 177 of the U.S. Code of Federal Regu-lations. Medias and Membranes are also in compliance with the USP Class VI Biological Test for Plastics.(Except Blk PP & PVC.)

Page 16

Page 18: ZenPure - Q-Test

ZenPure PureFlo® G50C Gas Filter Capsules

ZenPure Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

A8.5 Rev 2011.08

PureFlo® G50C Disc Capsules (50mm diameter) have been specially designed for simple, quick, and efficient filtration of gases. Eight different media options can be placed in an all-polypropylene or polyethylene shell construction for excellent chemical, gas compatibility. The small, compact design of the filter capsule allows for superior air flow rate and low backpres-sure. Ideal for vacuum pump protection from contamination. A hydrophobic 1um or smaller micron size should be used for the application. It can be used as a hydrophobic barrier to protect from viral and bacterial contamination. PTFE 0.2um and PE 0.2um rated filters can be used in sterile vent applications with extremely low resistance. Gamma sterilization resistant options are available.

Materials of ConstructionMembrane: Nylon, Nylon Screen Polyethylene, PES, Polypropylene Membrane, Polypropylene Media, Hydrophobic and Hydrophilic PTFE Membrane Supports: Polypropylene Capsule Body: PP, PE

Fitting Connections Luer Lock, Luer Slip, Hose Barb, Compression, NPT, Quick Cou-

plings, and more

Effective Filtration Area - 2.5in2 (15.9 cm2)

Autoclave Cycles - 10 times @ 257°F/125°C for 30 minutes Capsules must not be in situ steam-sterilized

Operating ConditionsMax. Working Pressure: PP/HDPE/PVC 80 PSID @ 77°F/25°C (5.5 bar)

Gamma PP 45 PSID @ 77°F/25°C (3.1 bar) Minimum burst pressure: PP/HDPE: 120 PSID @ 77° F/25°C (8.3 bar) Gamma PP: 60 PSID @ 77°F/25°C (4.1 bar) Maximum forward differential pressure: 60 PSID (4.1 bar) at 68°F (20°C) Maximum reverse differential pressure: 30 PSID (2.1 bar) at 68°F (20°C) Maximum Operating Temperature: PP & Gamma PP: 176°F/80°C HDPE: 140°F/60°C PVC: 122°F/50°C

Regulatory ComplianceThe discs are manufactured from materials that conform to the requirements of 21CFR Part 177 of the U.S. Code of Federal Regulations. Medias and Membranes are also in compliance with the USP Class VI Biological Test for Plastics. (Except Blk PP and

PVC)

PureFlo G50C Filter Capsules Ordering Guide

Polyethylene

(E)PTFE (F)

Glass

Fiber (G)

Polypro

Membrane (M)Nylon (N)

Nylon

Screen (NS)

Polypro

Media (P)PES (S)

E = Polyethylene 020 = 0.20 010 = 0.10 005 = 0.5 010 = 0.1 005= 0.05 100 = 10 003 = 0.3 005 = 0.05 OV = Male Medical Coupling Regular

OV = Male Medical Coupling Regular

Blank = Polypropylene Shell

F = PTFE 100 = 1.0 020 = 0.20 010 = 1.0 020 = 0.2 010 = 0.10 200 = 20 006 = 0.6 010 = 0.10

G = Glass Fiber 150 = 1.5 045 = 0.45 030 = 3.0 020 = 0.20 400 = 40 010 = 1.0 020 = 0.20M = PP Membrane 250 = 2.5 100 = 1.0 050 = 5.0 045 = 0.45 600 = 60 030 = 3.0 045 = 0.45 1N = 1/8" MNPT 1N = 1/8" MNPTN = Nylon 300 = 3.0 100 = 10 065 = 0.65 10X = 100 050 = 5.0 065 = 0.65 1NF = 1/4" FNPT 1NF = 1/4" FNPTNS = Nylon S

500 = 5.0 200 = 20 080 = 0.80 20X = 200 100 = 10 080 = 0.80P = PP Media 999 = 10 300 = 30 120 = 1.20 200 = 20 120 = 1.20 -1 = Single BaggedS = PES 300 = 30

400 = 40500 = 50 2H = 1/4"-3/8" Hose Barb 2H = 1/4"-3/8" Hose Barb -BLK = Black PP Shell700 = 70 2K = 1/4" Hose Barb 2K = 1/4" Hose Barb

15X = 150 2N = 1/4" MNPT 2N = 1/4" MNPT

200 = 20 2NF = 1/4" FNPT 2NF = 1/4" FNPT -OE = O-ring EPDM400 = 40 2QF = 1/4" Female Quick 2QF = 1/4" Female Quick -ON = O-ring Nitrile600 = 60 -OV = O-ring Viton730 = 73

1Q = 1/8" Male Quick Coupling

1Q = 1/8" Male Quick Coupling

1QF = 1/8" Female Quick Coupling

1QF = 1/8" Female Quick Coupling

2Q = 1/4" Male Quick Coupling for Metal latch

2QP = 1/4" Male Quick Coupling for Plastic latch

2Q = 1/4" Male Quick Coupling for Metal latch

2QP = 1/4" Male Quick Coupling for Plastic latch

Filter Media Output Fitting OptionsInput Fitting

-E = Polyethylene shell and HDPE media support for gamma sterilization

Pore Sizes (Micron)

OVS = Male Medical Coupling Short

OVS = Male Medical Coupling Short

-GP = Gamma stable Polypropylene Shell

Example – 1.0 Micron PTFE Filter Media with 1/4" hose barb fittings would be G50CF1002H2H

-ETO = Ethylene oxide sterilization

OVS is compatble w th -Parker/RECTUS 91 and 20 Wal her 06-003 and Value Plas ics -Bayonet Style Quick Connect

O-Ring for Quick

Coupling

Blank = O-ring Silicon (Standard)

Polyester

Screen (TS)

TS = Polyester Screen

PureFlo

G50C

Capsule

Filters

G50C = 50mm

Capsule filter

Page 17

Page 19: ZenPure - Q-Test

ZenPure PureFlo® G50C Vacuum/Vent Capsule

ZenP

ure

ZenPure Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

A8.6 Rev 2011.08

PureFlo G50C Filter Capsules Ordering Guide

Polyethylene (E) PTFE (F)

E = Polyethylene 020 = 0.20 010 = 0.10 OV = Male Medical Coupling Regular OV = Male Medical Coupling Regular

F = PTFE 100 = 1.0 020 = 0.20 OVS = Male Medical Coupling Short OVS = Male Medical Coupling Short

150 = 1.5 045 = 0.45 1N = 1/8" MNPT 1N = 1/8" MNPT250 = 2.5 100 = 1.0 1NF = 1/8" FNPT 1NF = 1/8" FNPT

300 = 3.0 1Q = 1/8" Male Quick Coupling 1Q = 1/8" Male Quick Coupling500 = 5.0 1QF = 1/8" Female Quick Coupling 1QF = 1/8" Female Quick Coupling999 = 10 2H = 1/4"-3/8" Hose Barb 2H = 1/4"-3/8" Hose Barb -1 = Single Bagged

2K = 1/4" Hose Barb 2K = 1/4" Hose Barb2N = 1/4" MNPT 2N = 1/4" MNPT2NF = 1/4" FNPT 2NF = 1/4" FNPT -BLK = Black PP shell

-OE = O-ring EPDM-ON = O-ring Nitrile-OV = O-ring VitonBlank = O-ring Silicon (Standard)

2QP = 1/4" Male Quick Coupling for Plastic latch

2QP = 1/4" Male Quick Coupling for Plastic latch

2Q = 1/4" Male Quick Coupling for Metal latch

2Q = 1/4" Male Quick Coupling for Metal latch

2QF = 1/4" Female Quick Coupling 2QF = 1/4" Female Quick Coupling

Pore Sizes (in Microns)

Input Fitting Output Fitting Options

G50C = 50mm Capsule filter

Blank = Polypropylene Shell

-E = Polyethylene Shell & HDPE media support for Gamma Sterilization

-GP = Gamma stable Polypropylene Shell

PureFlo G50C

Capsule FiltersFilter Media

Example – 1.0 Micron PTFE Filter Media with 1/4" hose barb fittings would be G50CF1002H2H

-ETO = Ethylene Oxide Sterilization

O-Ring for Quick Coupling

OVS is compatible with - Parker/RECTUS 91 and 20 Walther 06-003 and Value Plactics - Bayonet Style Quick Connect

Bacterial Retention - 0.2um

99.999% retention of Brevundimonas diminuta in accordance with the

current HIMA challenge methodology (ASTM F838-83).

Viral Retention - 0.2um

99.9999% retention with X174 Bacteriophage (25-27nm

(Nanometers), method adapted from ASTM F2101

HEPA – 1.0um and smaller Ensures particulate-free air 99.999% retention of 0.3 µm DOP aerosol

Pyrogenicity

<0.25 EU/ml using the LAL test method Autoclave Cycles - 10 times @ 257 F/125 C for 30 minutes

Capsules must not be in situ steam-sterilized

Regulatory Compliance Manufactured from materials that conform to the requirements of

21CFR Part 177 of the U.S. Code of Federal Regulations and USP

Class VI Biological Test for Plastics.. Meets bacterial filter require-ments suggested by the Center for Devices and Radiological Health,

Guidance Development for Power Suction Pump 510(k)s.

PureFlo® PTFE G50C Disc Capsules (50mm diameter) have been spe-

cially designed for simple, quick, and efficient vacuum protection. Hydro-

phobic PTFE membrane is placed in an all-polypropylene construction for

excellent chemical compatibility. The small, compact design of the filter

capsule allows for superior air flow rate and low system pressure resistance.

Provides an ideal effective barrier for vacuum/vent protection from bio-

hazardous contamination. The filter assists in meeting the

29CFR1910.1030 OSHA Blood borne Pathogen Standard by serving as an

“Engineering Control” to reduce human exposure. It can be used as a hydro-

phobic barrier to protect from viral and bacterial contamination.

Materials of Construction Membrane: PTFE with polypropylene supports

Capsule Body: Polypropylene

Fitting: Hose Barb, NPT, Quick Coupling and more Operating Conditions

Max. Working Pressure:

PP/HDPE/PVC 80 PSID @ 77 F/25 C (5.5 bar) Gamma PP 45 PSID @ 77 F/25 C (3.1 bar)

Minimum burst pressure:

PP/HDPE: 120 PSID @ 77 F/25 C (8.3 bar) Gamma PP: 60 PSID @ 77 F/25 C (4.1 bar)

Maximum forward differential pressure:

60 PSID (4.1 bar) at 68 F (20 C) Maximum reverse differential pressure:

30 PSID (2.1 bar) at 68 F (20 C)

Maximum Operating Temperature: PP & Gamma PP: 176 F/80 C

HDPE: 140 F/60 C PVC: 122 F/50 C

Page 18

Page 20: ZenPure - Q-Test

PureFlo D65R Filter Capsules

(Disc Capsule)

ZenPure Z

en

Pu

re

Versatile Disc Capsule filter

PureFlo® D65R Filter Capsules (65mm diameter) have been designed for simple, quick, and effi-cient filtration of fluids and gases used in labora-tory, pilot, and small-scale applications. The fam-ily of products is particularly suitable for scale up testing. Ten different media options can be placed in an all-polypropylene construction for excellent chemical compatibility. There are 18 different fit-ting options that can be mixed and matched for the inlet and outlet fittings.

The compact design of the filter capsule also re-duces hold-up volume and exposure to hazardous chemicals. No adhesives, binders, or surfactants are used in the manufacturing process. The unit is thermally-sealed to ensure integrity.

Applications Low flow Ink

Lab scale testing Beverages

Bio Bags Pharmaceuticals

Fine Chemicals Biologics

Vent Filter Scale up processing

Water Small volume Specifications

Materials of Construction: Media: Polypropylene, Nylon, PTFE, Polyethylene, Glass Fiber, and PES Media Supports: Polypropylene or Polyester Shell: Polypropylene or Polyethylene Sealing: Thermally-welded

Fitting Connections: See ordering guide for the availability. Any inlet/outlet combinations. (Custom adaptors available upon request)

Effective Filtration Area: 4in2 (26cm2)

Dimensions: 65mm (2.87in)

Available Ratings: 0.04um to 70um (see Ordering Guide)

Operating Conditions: Maximum Working Pressure: PP/HDPE/PVC 80 PSID @ 77°F/25°C (5.5 bar) Gamma PP 45 PSID @ 77°F/25°C (3.1 bar)

Minimum Burst pressure: PP/HDPE: 120 PSID @ 77° F/25°C (8.3 bar) Gamma PP: 60 PSID @ 77°F/25°C (4.1 bar) Maximum Forward differential pressure: 60 PSID (4.1 bar) at 68°F (20° C) Maximum Reverse differential pressure: 30 PSIG (2.1 bar) at 68°F (20° C)

Maximum Operating Temperature: PP & Gamma PP: 176°F/80°C HDPE: 140°F/60°C PVC: 122°F/50°C

Autoclave Cycles: The filters can be sterilized by autoclaving for 10 cycles at 257°F/125°C for 30 minutes, except for PE membrane. Capsules must not be in situ steam-sterilized.

Page 19

Page 21: ZenPure - Q-Test

ZenPure PureFlo D65R Filter Capsules

Your Local Distributor:

A9 Rev 2011.08

ZenPure

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

PureFlo D65R Filter Capsule Ordering Guide

Dimensions (mm)

51

59

55

57

1/4" MNPT

5/16"-3/8" Hose Barb

1/4" Hose Barb

1/8" Hose Barb

D65R-×-×××-2N

D65R-×-×××-3H

D65R-×-×××-2H

D65R-×-×××-1H

ASize( 1)Outlet FittingInlet FittingCode name

D65R-×-×××-3NF

71

613/8" Female

D65R-×-×××-2NF

D65R-×-×××-3N 3/8" MNPT

1/4"FNPT

55

D65R-×-×××-TC

74

761.5" Tri Clamp

D65R-×-×××-4N

D65R-×-×××-MT 1/2" Tri Clamp

1/2"Male

69

D65R-×-×××-LF Luer Lock Female

1.5" Tri Clamp

1/2" Tri Clamp

5/16"-3/8" Hose Barb

1/2"Male

1/8" Hose Barb

3/8" Female

3/8" MNPT

1/4" MNPT

1/4" Hose Barb

1/4"FNPT

Luer Lock Female 38

1/8" Male Quick CouplingD65R-×-×××-1Q 1/8" Male Quick Coupling 45

1/4" Male Quick CouplingD65R-×-×××-2Q 1/4" Male Quick Coupling 58

1/8"FNPTD65R-×-×××-1NF 1/8"FNPT 52

Female VentilatorD65R-×-×××-MVFV Male Ventilator 75

3/8"MNPTD65R-×-×××-MF3N Male Ventilator 62

1/8"Female Quick CouplingD65R-×-×××-1QF 1/8" Female Quick Coupling 85

1/4" Female Quick CouplingD65R-×-×××-2QF 1/4" Female Quick Coupling 90

Carbon

Fiber (C)

Charged

Nylon (CN)

Depth PP

(DP)

Polyethylene

(E)PTFE (F)

Glass

Fiber (G)

Polypro

Membrane (M)Nylon (N)

Nylon

Screen (NS)

Polypro

Media (P)PES (S)

C = Carbon Fiber 005= 0.05 002 = 0.2um 020 = 0.20 010 = 0.10 005 = 0.5 010 = 0.1 005= 0.05 100 = 10 003 = 0.3 005 = 0.05 1H = 1/8" Hose Barb 1H = 1/8" Hose Barb Blank = Polypropy ene Shell010 = 0.10 005 = 0.5um 100 = 1.0 020 = 0.20 010 = 1.0 020 = 0.2 010 = 0.10 200 = 20 006 = 0.6 010 = 0.10 1NF = 1/8" FNPT 1NF = 1/8" FNPT -GP = Gamma stabil zed PP shell020 = 0.20 010 = 1.0um 150 = 1.5 045 = 0. 5 030 = 3.0 020 = 0.20 400 = 0 010 = 1.0 020 = 0.20 1Q = 1/8" Male Quick Coupling 1Q = 1/8" Male Quick Coup ing -NY = Nylon Shell

DP = Depth PP 045 = 0. 5 015 = 1.5um 250 = 2.5 100 = 1.0 050 = 5.0 045 = 0. 5 600 = 60 030 = 3.0 045 = 0. 5 1QF = 1/8" Female Quick 1QF = 1/8" Female Quick E = Polyethylene 065 = 0.65 025 = 2.5um 300 = 3.0 100 = 10 065 = 0.65 10X = 100 050 = 5.0 065 = 0.65 2H = 1/ "-5/16" Hose Barb 2H = 1/ "-5/16" Hose BarbF = PTFE 080 = 0.80 045 = .5um 500 = 5.0 200 = 20 080 = 0.80 20X = 200 100 = 10 080 = 0.80 2N = 1/ " MNPT 2N = 1/ " MNPTG = Glass Fiber 120 = 1.20 100 = 10um 999 = 10 300 = 30 120 = 1.20 200 = 20 120 = 1.20 2NF = 1/ " FNPT 2NF = 1/ " FNPT -1 = Single BaggedM = PP Membrane 200 = 20um 300 = 30 -NV= No vent fittingN = Nylon 400 = 0 -FB = Fi ling Bell (with 2H only)NS = Nylon 500 = 50 -FC = Fi ling Bell w/ Cap (with 2H P = PP Media 700 = 70 -BLK = Black PP ShellS = PES 15X = 150 3H = 5/16-3/8" Hose Barb 3H = 5/16-3/8" Hose Barb

200 = 20 3N = 3/8" MNPT 3N = 3/8" MNPT400 = 0 3NF = 3/8" FNPT 3NF = 3/8" FNPT600 = 60 4N = 1/2" MNPT 4N = 1/2" MNPT730 = 73 FV = Female Ventilator FV = Female Ventilator

LF = Female Luer Lock LF = Female Luer Lock MT = 1/2" Tri Clamp MT = 1/2" Tri Clamp -OE = O-ring EPDMMV = Male Ventilator MV = Male Ventilator -ON = O-ring NitrileTC = 1.5" Tri Clamp TC = 1.5" Tri Clamp -OV = O-ring Viton

-E = Polyethy ene Shell and HDPE media support for gamma ster lizat on

Blank = O-ring Silicon (Standard)

-ETO = Ethylene oxide sterilization

O-Ring for Quick Coupling

Leave Pore Size Blank for Carbon

Fiber

TS = Polyester Screen

2QF = 1/ " Female Quick Coupling with Metal latch

2Q = 1/ " Male Quick Coup ing for Metal latch

2QF = 1/ " Female Quick Coupling with Metal latch

Pore Sizes (Micron)

Input Fitting Output Fitting

CN = Charged Nylon

Polyester

Screen (TS)

Options

2Q = 1/ " Male Quick Coupling for Metal latch

D65R =

65mm Capsule filter

PureFlo

D65R

Capsule

Filters

Filter Media

Example – 1.2 Micron Nylon Filter Media with 1/2 tri clamp i tings would be D65RN120MTMT For Same f lter wi h Carbon Fiber D65RCMTMT

Regulatory Compliance:

The filters are constructed with polypropylene resins and filtration media in compliance with 21CFR Part 177 of the US Code of Federal Regula-tions and USP Class VI Bio-logical Test for Plastic. (Except Blk PP and PVC)

Page 20

Page 22: ZenPure - Q-Test

ZenPure Silicon Heater for the D65

Zen

Pu

re

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

A9.2 Rev 2011.07

D65 Silicon Heater

Silicon Heaters for the D65 are a reliable heat source capable of operating with excellent performance un-der many adverse conditions. This unit was designed to prevent condensation build up in the filter. The flexible silicon rubber are made of low mass construc-tion to provide rapid heat-up due to direct bonding to the part. Flexible heaters provide uniform heat trans-fer to irregular shaped or flat surfaces including three dimensional geometries, conforming to the filter be-ing heated. They are not affected by mechanical shock, vibration for repeated flexing and will not stretch or tear.

D65 Silicon Heater Part number Guide

Specifications Size: 3.75 x 3.75” 0.75” hole in center Wire:60” leads Thermocouple: Type K Operation Voltage: 24Volts, 4 watts Design :Fold Over Pocket Closure :Velcro straps

Performance ratings Max. Temperature: 392F/ 200C Min Temperature : -80F/-62.2C Physically Resistant To: Moisture, Ozone, Fungus,

and Radiation

Additional Information Leads are Teflon® insulated, UL 1180,

type EE, flexible, stranded, plated copper wire rated for 392F (200C) and 300 volts. On silicon rubber heaters, the lead con-nections are insulated with vulcanized sili-con rubber, which also acts as a strain re-lief.

Part number: D65-SHS80501—Silicon Rubber Surface Heater, 60” Teflon lead, Fold– over pocket

design with Velcro closure

Other custom units can be designed

Page 21

Page 23: ZenPure - Q-Test

PureFlo® Junior Capsules

Compact Filtration

ZenPure Z

en

Pu

re

Small Disposable Process Filtration

PureFlo® Junior capsule filter assemblies are ready-to-use filters that offer high flows, increased throughputs, high strength, all with the convenience and cleanliness of a disposable and easy-to-install filter assembly in a small package. Designed for small pre-filtration, clarification, and final filtration, in pharmaceutical, biotechnology, food and beverage, medical, chemical, and DI water applica-tions.

PureFlo® Junior capsule assemblies are available with a wide range of hydrophilic and hydrophobic filter medias and pore sizes for liquid, gas, and venting applications. Process engineers can choose from 11 filtration medias to create any combination of integrated filtration. These will allow the disposable processing to become truly flexible, clean, and optimal.

They can be built with several configurations, with five inlet and outlet fitting connections that can be mixed and matched. The filtration shell is an all-polypropylene con-struction that provides excellent chemical compatibility with low extractables. The shell and supports can also be constructed in nylon, polyethylene, or gamma stabilized PP shells for additional compatibility. No adhesives, bind-ers, or surfactants are used in the manufacturing proc-ess.

Specifications

Materials of Construction: Media: Charged Nylon, Depth PP, Polyethylene, PTFE, Glass Fiber, PP Membrane, Nylon, Nylon Screen, PP media, PES, and Polyester Screen Media Supports: Polypropylene, Polyester, Nylon, or HDPE Shell, Cage, Core, End Caps: Polypropylene, Nylon, or HDPE Sealing: Thermally bonded

Fitting Connections: Five Fittings - See Ordering Guide for availability. (Custom adaptors available upon request)

Nominal Dimensions: Lengths: 1.6” (41mm) without fittings Diameter: 1.6” (41mm)

Effective Filtration Area: 260cm2 for single layer membrane, 230cm2 for double layer membrane 200cm2 for Depth and Screen Media Available Ratings: 0.04um - 200.0um (Dependent on Media) Operating Conditions: Maximum Operating pressure: Liquid: 5.5 bar (80psi) at 77°F/25°C Gas: 4.1 bar (60psi) at 77°F/25°C Minimum Burst Pressure: 8.3 bar (120psi) at 77°F/25°C Maximum Forward Differential Pressure: 5 bar (72psi) at 68°F/20°C Maximum Reverse Differential Pressure: 2.1 bar (30psi) at 68°F/20°C

Maximum Operating Temperature: PP & Gamma PP: 176°F/80°C HDPE: 140°F/60°C

Regulatory Compliance: The filters are constructed with polypropylene resins and filtration media in compliance with 21CFR Part 177 of the US Code of Federal Regulations and USP Class VI Biological Test for Plastics. (Except Blk PP)

Applications

Clarification Water & Wine

Hard Particle Food & Beverages Cell Removal Pharmaceuticals Chemicals Biologics Inks, Dyes Oils, Waters Cosmetics Diagnostics

Page 22

Page 24: ZenPure - Q-Test

ZenPure PureFlo® Junior Capsules

ZenPure Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

A9.3 Rev 2011.08

PureFlo® Junior Filter Capsule Ordering Guide

Specifications (cont.)

Autoclavable & Sanitizable: Capsules can be autoclaved 25 times at 257°F/125°C for 30 minutes or chemically sanitized in situ using common sanitizing agents or hot water at 194°F/90°C for a limited time (dependent on time and temperature). Capsules must not be in situ steam-sterilized.

Bacterial Endotoxin: Effluent is non-pyrogenic per USP Bacterial Endotoxin (0.25 EU/ml), determined using Limulus Amebocyte Lysate (LAL) Test.

Charged

Nylon (CN)

Depth PP

(DP)

Polyethyle

ne (E)PTFE (F)

Glass

Fiber (G)

Polypro

Membrane (M)Nylon (N)

Nylon

Screen (NS)

Polypro

Media (P)Philic

PTFE PES (S)

005= 0.05 002 = 0.2 020 = 0.20 010 = 0.1 005 = 0.5 010 = 0.1 005= 0.05 100 = 10 003 = 0.3 Request 005 = 0.05010 = 0.10 005 = 0.5 100 = 1.0 020 = 0.2 010 = 1.0 020 = 0.2 010 = 0.10 200 = 20 006 = 0.6 010 = 0.1020 = 0.20 010 = 1.0 150 = 1.5 045 = 0.45 030 = 3.0 020 = 0.20 400 = 40 010 = 1.0 020 = 0.2045 = 0.45 015 = 1.5 250 = 2.5 100 = 1.0 050 = 5.0 045 = 0.45 600 = 60 030 = 3.0 045 = 0.45065 = 0.65 025 = 2.5 300 = 3.0 100 = 10.0 065 = 0.65 10X = 100 050 = 5.0 065 = 0.65080 = 0.80 045 = 4.5 500 = 5.0 200 = 20.0 080 = 0.80 20X = 200 100 = 10.0 080 = 0.8120 = 1.20 100 = 10.0 999 = 10.0 300 = 30.0 120 = 1.20 200 = 20.0 120 = 1.2

200 = 20.0 300 = 30.0500 = 50.0700 = 70.0

Pore size (Micron)

PureFlo Junior

Capsule Filters

PreFilter Filter

Media

PreFilter Pore Size

(Micron)Final Filter Media

Pore Size

(Micron)Inlet Fitting Outlet Fitting Options

CN = Charged Nylon CN = Charged Nylon 1H = 1/8" Hose Barb 1H = 1/8" Hose BarbE = Polyethylene DP = Depth PolyPro 1Q = 1/8" Male Quick Coupling 1Q = 1/8" Male Quick CouplingF = PTFE E = Polyethylene 2H = 1/4" Hose barbs 2H = 1/4" Hose barbsG = Glass Fiber F = PTFE 2N = 1/4" MNPTM = PolyPro Mem G = Glass Fiber 2NO = 1/4" MNPT w/O-RingN = Nylon M = PolyPro MemNS = Nylon Screen N = NylonP = PolyPro Media NS = Nylon Screen 3H = 3/8" Hose BarbHF = Hydrophilic PTFE P = PolyPro Media LF = Female Luer LockS = PES HF = Hydrophilic PTFE MT = 1/2" Tri clamps 3H = 3/8" Hose Barb

S = PES LF = Female Luer LockMT = 1/2" Tri clamps -BLK = Black PP Shell

O-Ring for Quick Coupling

Blank - for MJ Cartridge

-OE = O-Ring EPDM-ON = O-Ring Nitrile-OV = O-Ring Viton

-ETO = Ethylene oxide sterilization

-GP = Gamma stable polypropylene shell

Example - JKL Series, PTFE, 1 0um, no prefilter, 1/4" Hose Barb I/O is JKLF1002H2H

MJ = Cartridge Filter, PP parts standard Grade

JKL = Capsule filter PP parts

Standard grade

-E = Polyethylene shell and HDPE media support for gamma sterilization

( , and PES Media

only)

Example - JKP Series, PES 0.8um prefilter, PES 0.2um, 1/4" Hose Barb I/O is JKPS0800202H2H

JNL = Capsule filter Nylon parts

Other Custom options are possible

JKP = Capsule Filter Pharma grade

Blank = No Pre filter

Pick From Pore

Size Table

Pick From Pore

Size Table

2Q = 1/4" Male Quick Coupling for Metal latch

2H -FB= 1/4" Hose barbs with Filling Bell

2H -FC= 1/4" Hose barbs with Filling Bell with Cap

2Q = 1/4" Male Quick Coupling for Metal latch

Blank = O-Ring Silicon (Standard)

Blank = No Pre filter Blank = Same media as Prefilter

-N = No vent or drain fittings

-NI = No vent or drain inlet fitting

-NO = NO vent or drain outlet fitting

1/8 Hose barbs

0.5" Tri clamps1/4 Hose barbs

0.5" Tri clamps/1/4" Hose barbs416941

7182

41

BA

Vent/DrainInlet/OutletSize( 1.5)

Female Luer LockFemale Luer LockFemale Luer Lock

Code name

JKL-1H1H

JKL-2H2H

JKL-MTMT

JKL-MT2H 75 41Female Luer Lock

41108Female Luer Lock1/4"NPT MAIL/1/4" Hose barbs

JKL-LFLF

41JKL-3H3H 3/8" Hose barbs Female Luer Lock4162

88Female Luer LockLuer Lock Female

JKL-2Q2Q 1/4" Male Quick Compling Female Luer Lock 82 41JKL-2NS2HFB

41751/8 Male Quick ComplingJKL-1Q1Q Female Luer Lock

Page 23

Page 25: ZenPure - Q-Test

MKL Series Filter Capsules

(Mini Capsule)

ZenPure Z

en

Pu

re

Versatile Small Capsule filter

PureFlo® MKL Series capsules were designed for small-scale filtration, clarification, and filling ap-plications in the pharmaceutical, biotechnology, food and beverage, medical, chemical, water in-dustries worldwide. This family of products is par-ticularly suitable for scale-up testing where a full size capsule or cartridge would be excessive. They are also very suitable for disposable Bio-bag applications.

The MKL capsules have a compact design that can incorporate 200, 300, 400 or 500 cm2 of fil-tration material to meet the needs of different ap-plications. We are currently offering nine different media options with 15 different fitting options. The different possible materials of construction can provides excellent compatibility with a wide-range of chemicals such as acids, bases and solvents. No adhesives , binders, or surfactants are used in the manufacturing process. All units are thermally-sealed and 100% integrity tested.

Applications Low flow Ink

Lab scale testing Beverages

Bio Bags Pharmaceuticals

Fine Chemicals Biologics

Vent Filter Scale up processing

Water Small volume

Specifications Materials of Construction: Media: Polypropylene, Nylon, PTFE, Polyethylene, Glass Fiber, and PES Media Supports: Polypropylene or Polyester Cage, Core, End Caps: Polypropylene or Polyethylene Sealing: Thermally-welded

Fitting Connections: See ordering guide for the availability. Any inlet/outlet combinations. (Custom adaptors available upon request)

Nominal Dimensions: Lengths: 3.9 in. (99mm) Diameter: 2.3 in. (60 mm)

Available Ratings: 0.04um to 70um (see Ordering Guide)

Operating Conditions: Maximum Operating Pressure: Liquid: 5.5 bar (80psi) at 77°F/25°C Gas: 4.1 bar (60psi) at 77°F/25°C Maximum Forward Differential Pressure: 5.0 bar (72 psid) at 68°F/20°C Maximum Reverse Differential Pressure: 2.1 bar (30 psid) at 176°F/80°C

Maximum Operating Temperature: PP & Gamma PP: 176°F/80°C HDPE: 140°F/60°C Minimum Burst Pressure: 8.3 bar (120 psid) at 77°F/25°C

Autoclavable & Sanitizable: Capsules can be autoclaved 25 times at 257°F/125°C for 30 minutes or chemically sani-tized in situ using common sanitizing agents or hot water at 194°F/90°C for a limited time (dependent on time and temperature). Capsules must not be in situ steam-sterilized.

Regulatory Compliance: The filters are constructed with polypropylene resins and filtration media in compliance with 21CFR Part 177 of the US Code of Federal Regulations and USP Class VI Biological Test for Plastic. (Except Blk PP)

Page 24

Page 26: ZenPure - Q-Test

ZenPure MKL Series Filter Capsules

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

A9.5 Rev 2011.08

PureFlo MKL Series Filter Capsule Ordering Guide

PureFlo Capsule

FiltersFilter Media

Pore size

(Micron)

Surface

AreaInlet Fitting Outlet Fitting Option

CN = Charged Nylon A = 200cm2 1C = 1/8" Compression 1C = 1/8" CompressionMKL = Capsule filter DP = Depth PolyPro B = 300cm2 1H = 1/8" Hose Barb 1H = 1/8" Hose Barb

Standard grade E = Polyethylene C = 400cm2 1Q = 1/8" Male Quick Coupling 1Q = 1/8" Male Quick CouplingF = PTFE D = 500cm2 1QE = 1/8" Male Quick Coupling Elbow

MKP = Pharma grade G = Glass Fiber 2C = 1/4" CompressionM = PolyPro Mem 2C = 1/4" Compression 2CE = 1/4" Compression ElbowN = Nylon 2CE = 1/4" Compression Elbow 2H = 1/4" Hose barbs -N = No vent or drain fittingsNS = Nylon Screen 2H = 1/4" Hose barbs 2H -FB = 1/4" Hose barbs with Filling Bell -NI = No vent or drain inlet fittingP = PolyPro Media 2N = 1/4" MNPT 2H -FC = 1/4" Hose barbs with Filling Bell w/ Cap -NO = NO vent or drain outlet

fittiHF = Hydrophilic PTFE 2NO = 1/4" MNPT+EP O-Ring 2N = 1/4" MNPT -NY = Nylon ShellS = PES 2NO = 1/4" MNPT+EP O-Ring

2Q = 1/4" Male Quick Coupling for Metal latch -BLK = Black PP Shell-ETO = Ethylene oxide sterilization

2QF = 1/4" Female Quick Coupling with Metal O-Ring for Quick Coupling

3H = 3/8" Hose Barb Blank = O-ring Silicone (Standard)3H = 3/8" Hose Barb 3H -FB = 3/8" Hose barbs with Filling BellLF = Female Luer Lock 3H -FC = 3/8" Hose barbs with Filling Bell w/ Cap -OE = O-ring EPDMLFE = Female Luer Lock Elbow LF = Female Luer Lock -ON = O-ring NitrileMT = 1/2" Tri clamps LFE = Female Luer Lock Elbow -OV = O-ring Viton

MT = 1/2" Tri clampsExample - MKL Series, PTFE, 1.0um, 500cm2, 1/4" Hose Barb I/O is MKLF100D2H2H

2Q = 1/4" Male Quick Coupling for Metal latch

2QF = 1/4" Female Quick Coupling with Metal latch

-GP = Gamma stable polypropylene shell

Pick From Pore

Size Table

1QE = 1/8" Male Quick Coupling Elbow

2QE = 1/4" Male Quick Coupling for Metal latch Elbow

( For PTFE, PES and PE Media only)

2QE = 1/4" Male Quick Coupling for Metal latch Elbow

-E = Polyethylene shell and HDPE media support for gamma sterilization

Charged

Nylon (CN)Depth PP (DP) Polyethylene (E) PTFE (F) Glass Fiber (G)

Polypro

Membrane (M)Nylon (N)

Nylon Screen

(NS) PP Media (P) Philic PTFE PES (S)

005= 0 05 002 = 0.2 020 = 0.20 010 = 0.1 005 = 0.5 010 = 0.1 005= 0.05 100 = 10 003 = 0.3 Request 005 = 0.05010 = 0.10 005 = 0.5 100 = 1.0 020 = 0.2 010 = 1.0 020 = 0.2 010 = 0.10 200 = 20 006 = 0.6 010 = 0.1020 = 0.20 010 = 1.0 150 = 1.5 045 = 0.45 030 = 3.0 020 = 0.20 400 = 40 010 = 1.0 020 = 0.2045 = 0.45 015 = 1.5 250 = 2.5 100 = 1.0 050 = 5.0 045 = 0.45 600 = 60 030 = 3.0 045 = 0.45065 = 0.65 025 = 2.5 300 = 3.0 100 = 10.0 065 = 0.65 10X = 100 050 = 5.0 065 = 0.65080 = 0.80 045 = 4.5 500 = 5.0 200 = 20.0 080 = 0.80 20X = 200 100 = 10.0 080 = 0.8120 = 1.20 100 = 10.0 999 = 10.0 300 = 30.0 120 = 1.20 200 = 20.0 120 = 1.2

200 = 20.0 300 = 30.0500 = 50.0700 = 70.0

Only available Only available Only available Only available Only available

in Surface Area in Surface Area in Surface Area in Surface Area in Surface Area

A (<200cm2) C (400cm2) C (400cm2) C (400cm2) C (400cm2)

Pore size (Micron)

Dimensions (mm)

A B C

1C 1/8" Commpression 94 74 60

2C 1/8" Commpression 99 74 60

1Q 1/8"Male Quick Coupling 97 74 60

2Q 1/4"Male Quick Coupling 102 74 60

2N 1/4" MNPT 100 74 60

2H 1/4" Hose Barb 98 74 60

LF Female Luer Lock 90 74 60

MT 0.5" Tri Clamp 114 74 60

1H 1/8" Hose Barb 96 74 60

3H 3/8" Hose Barb 124 74 60

LFE Female Luer Lock Elbow 100 74 60

2CE 1/8" Commpression Elbow 100 74 60

1QE 1/8"Male Quick Coupling Elbow 100 74 60

2QE 1/4"Male Quick Coupling Elbow 100 74 60

SizeFitting

CodeFitting Description

0.5" Tri Clamp by 1.4" Hose Barb

with Filling BellMT2HFB 135 74 60

Page 25

Page 27: ZenPure - Q-Test

MKP Series Polyethylene Filter Capsules

(PE/PE Construction)

ZenPure Z

en

Pu

re

Specification Materials of Construction: Membrane: Polyethylene Media Supports: High Density Polyethylene (HDPE) Cage, Core, End Caps: HDPE Valve O-Rings: Silicon (Standard) Sealing: Thermally welded Fitting Connections: See Ordering Guide for the availability. Any inlet/outlet combinations. (Custom adaptors available upon request) Nominal Dimensions: Lengths: 3.9 in. (99 mm) - dependent on fitting

Diameter: 2.3 in. (60 mm)

Available Ratings: 0.2um to 2.5um (see Ordering Guide) Operating Conditions: Maximum Forward Differential Pressure: 73 psid (5.0 bar) at 20°C

36 psid (2.5 bar) at 50°C 17 psid (1.2 bar) at 80°C

Maximum Reverse Differential Pressure: 44 psid (3.0 bar) at 20°C Maximum Operating Temperature: 80° C Regulatory Compliance: The filters are constructed with polypropylene resins and filtration media in compliance with 21CFR Part 177 of the U.S. Code of Federal Regulations and USP Class VI Biological Test for Plastics.

Applications

Buffers and Media Fermentation Tank

Product Sterilization Venting

Bio Bags Pharmaceuticals

Vaccines Biologics

Gas Filtration Scale up processing

Versatile Small Capsule filter

PureFlo® MKP Series Polyethylene (PE) capsules were designed for small to medium-scale filtration, clarification, and venting applications in the pharmaceu-tical, biotechnology, food and beverage, medical and water industries worldwide. This family of products is particularly suitable for venting applications where the units need to be gamma sterilized with other disposable units for venting. The hydrophobic PE membrane is ideally suited for air, gas and liquid sterilizing applications.

The hydrophobic membrane provides superior flow and pressure-drop characteristics for small tank and bio-bag venting applications. The MKP capsules have a compact design that can incorporate 400 cm2 of filtration material to meet the needs of a wide variety of processes. We are currently offering four different polyethylene media sizes with 15 different fitting options. The units are thermally-sealed. No adhesives , binders, or surfactants are used in the manufacturing process. The units are rinsed with pyrogen-free water to reduce extractables and downtime. All filter capsules are 100% integrity-tested to ensure filter performance each and every time out of the package.

Page 26

Page 28: ZenPure - Q-Test

Your Local Distributor:

ZenPure

A9.6 Rev 2011.08

MKP Series PE Filter Capsules

ZenPure North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

Specifications (cont.)

Bacterial Retention (for 0.2um membrane): Complete retention of > 107organisms/cm2 of Brevundimonas diminuta in accordance with the current HIMA challenge method-ology (ASTM F838-83). Validation Guide upon request.

Sanitizable:

The filters can be gamma sterilized up to 45kGy. Not Autoclavable.

Bacterial Endotoxin:

Effluent is non-pyrogenic per USP Bacterial Endotoxin (0.25 EU/ml), determined using Limulus Amebocyte Lysate (LAL) Test.

PureFlo MKP Series PE Filter Capsule (Pharmaceutical grade) Ordering Guide

A B C

1C 1/8" Commpression 94 74 60

2C 1/8" Commpression 99 74 60

1Q 1/8"Male Quick Coupling 97 74 60

2Q 1/4"Male Quick Coupling 102 74 60

2N 1/4" MNPT 100 74 60

2H 1/4" Hose Barb 98 74 60

LF Female Luer Lock 90 74 60

MT 0.5" Tri Clamp 114 74 60

1H 1/8" Hose Barb 96 74 60

3H 3/8" Hose Barb 124 74 60

LFE Female Luer Lock Elbow 100 74 60

2CE 1/8" Commpression Elbow 100 74 60

1QE 1/8"Male Quick Coupling Elbow 100 74 60

2QE 1/4"Male Quick Coupling Elbow 100 74 60

SizeFitting

CodeFitting Description

0.5" Tri Clamp by 1.4" Hose Barb

with Filling BellMT2HFB 135 74 60

Dimensions (mm)

PureFlo

Capsule

Filters

Filter MediaPore size

(Micron)

Surface

AreaInlet Fitting Outlet Fitting Option

020 = 0 20 A = 200cm2 1C = 1/8" Compression 1C = 1/8" Compression100 = 1 0 B = 300cm2 1H = 1/8" Hose Barb 1H = 1/8" Hose Barb

E = Polyethylene 150 = 1 5 C = 400cm2 1Q = 1/8" Male Quick Coupling 1Q = 1/8" Male Quick Coupling250 = 2 5 D = 500cm2 1QE = 1/8" Male Quick Coupling Elbow

2C = 1/4" Compression2C = 1/4" Compression 2CE = 1/4" Compression Elbow2CE = 1/4" Compression Elbow 2H = 1/4" Hose barbs2H = 1/4" Hose barbs 2H -FB = 1/4" Hose barbs with Filling Bell

2N = 1/4" MNPT 2H -FC = 1/4" Hose barbs with Filling Bell with Cap

2NO = 1/4" MNPT+EP O-Ring 2N = 1/4" MNPT2NO = 1/4" MNPT+EP O-Ring2Q = 1/4" Male Quick Coupling for Metal latch

2QF = 1/4" Female Quick Coupling with Metal latch3H = 3/8" Hose Barb

3H = 3/8" Hose Barb 3H -FB = 3/8" Hose barbs with Filling Bell O-Ring for Quick

Coupling

LF = Female Luer Lock 3H -FC = 3/8" Hose barbs with Filling Bell with Cap

LFE = Female Luer Lock Elbow LF = Female Luer Lock MT = 1/2" Tri clamps LFE = Female Luer Lock Elbow -OE = O-ring EPDM

MT = 1/2" Tri clamps -ON = O-ring Nitrile-OV = O-ring Viton

MKP = Pharma grade

-NI = No vent or drain inlet fitting

-NO = NO vent or drain outlet fitting

-ETO = Ethylene oxide sterilization

Example - MKPE Series, Polyethylene, 020um, 500cm2, 1/4" Hose Barb I/O is MKPE020D2H2H

Blank = O-ring Silicon (Standard)

-E = Polyethylene shell and HDPE media support for gamma sterilization

1QE = 1/8" Male Quick Coupling Elbow

-N = No vent or drain fittings

2Q = 1/4" Male Quick Coupling for Metal latch

2QE = 1/4" Male Quick Coupling for Metal latch Elbow

2QE = 1/4" Male Quick Coupling for Metal latch Elbow

2QF = 1/4" Female Quick Coupling with Metal latch

Page 27

Page 29: ZenPure - Q-Test

ZenPure Ze

nPur

e

1H = 1/8" Hose barbs X X X1NF = 1/8" FNPT X X2C = 1/4" Compression X2H = 1/4" to 1/2" Hose barbs, 1/4" Hose barb X X X2HS = 1/4" to 3/8" Hose barbs X X2LF = Large Female Luer Lock fitting X2N = 1/4" MNPT X X X2NF = 1/4" FNPT X X X2Q = 1/4" Male Quick Coupling for Metal latch X X2QF = 1/4" Female Quick Coupling with Metal latch X X2QFP = 1/4" Female Quick Coupling with Plastic latch (threaded on) X X X2QP = 1/4" Male Quick Coupling for Plastic latch X X3C = 3/8" Compression X3H = 3/8" Hose Barb X X3HE = 3/8" Hose Barb Elbow X X3NF = 3/8" FNPT X X X4C = 1/2" Compression X4H = 1/2" Hose Barb X X4N = 1/2" MNPT X X X4QP = 1/2" Male Quick Coupling for Plastic latch X XMT = 1/2" Tri clamps X X XTC = 1-1/2" Tri clamp X X X

Option: Plugged and Cut off Vent and/or Drains

SK Capsule Vent and Drain options

Inlet/Outlet Fittings Luer Lock

(SKL)

Bleed Valve

(SKV)

M8 Plug

(SKP)

Compression

(SKP)

M8 Plug Luer Lock Bleed valveM8 Plug Compression

SK Capsule Series Vent Options Note—Not available on every Inlet/Outlet fitting

SKP SKL SKV SKP

Page 28

Page 30: ZenPure - Q-Test

ZenPure ZenPure SKV Series Capsule Size & Fitting Options

Zen

Pu

re

Page 29

Page 31: ZenPure - Q-Test

ZenPure ZenPure SKL Series Capsule Size & Fitting Options

Zen

Pu

re

Page 30

Page 32: ZenPure - Q-Test

ZenPure

This page left blank intentionally

Zen

Pu

re

Page 31

Page 33: ZenPure - Q-Test

SKV Series PES Filter Capsules

(PES/PP Construction)

ZenPure Z

en

Pu

re

Pharmaceutical Capsule filter

The PureFlo® SKV Series PES filter capsule with all-polypropylene construction provides excellent chemical compatibility and superior flow per unit area as com-pared to other membrane capsules. The PureFlo® PES filter capsules have been specially designed for steriliz-ing in biopharmaceutical applications. The hydro-philic PES membrane does not require pre-wetting agents, thereby eliminating a potential source of contamination. The PES membrane is a low protein-binding media.

The capsules were designed with built-in bleed valves for simple and efficient evacuation of air and liquid. The units are used for filtration of small to medium volumes used in production, laboratory and pilot runs. No adhesives, binders, or surfactants are used in the manufacturing process of these capsules. They are rinsed with pyrogen-free water to reduce extractables and downtime. All filter capsules are 100% integrity-tested to ensure filter performance each and every time out of the package. PureFlo SKV Series PES filter capsules are well-suited for pharmaceutical applications where superior flow and bacterial retention is required. The capsule can be ordered pre-sterilized.

Applications

Buffers and Media Fermentation Broths

Product Sterilization SVP (Small Volume Par-

enterals)

Bio Bags Pharmaceuticals

Vaccines Biologics

Antibiotics Scale up processing

Water Serums Specifications Materials of Construction: Media: PES (Polyethersulfone) Media Supports: Polypropylene Cage, Core, End Caps: Polypropylene Valve O-Rings: Silicon (Standard); Sealing: Thermally welded Fitting Connections: See ordering guide for the availability. Any inlet/outlet combinations. (Custom adaptors available upon request) Nominal Dimensions: Lengths: 1.5 in (68 mm), 2.5 in (98 mm),5.0 in (153mm), 7.5 in (251mm),

10 in (281mm) Diameter: 2.88 in (73 mm) Effective Filtration Area: 1.5in: 0.77 ft2 (720 cm2), 2.5in: 1.48 ft2 (1380 cm2), 5.0in: 2.8 ft2 (2600 cm2), 7.5in: 4.3ft2 (3980cm2), 10in: 5.6 ft2 (5200 cm2)

Operating Conditions: Maximum Forward Differential Pressure: Liquid: 5.5 bar (80psi) at 77°F/25°C Gas: 4.1 bar (60psi) at 77°F/25°C Minimum Burst Pressure: 8.3 bar (120psi) at 77°F/25°C Maximum Forward Differential Pressure: 5 bar (72psi) at 68°F/20°C Maximum Reverse Differential Pressure: 3.0 bar (44psi) at 68°F/20°C

Maximum Operating Temperature: PP & Gamma PP: 176°F/80°C HDPE: 140°F/60°C

Regulatory Compliance: The filters are constructed with polypropylene resins and filtration media in compliance with 21CFR Part 177 of the US Code of Federal Regulations and USP Class VI Biological Test for Plastic.

Page 32

Page 34: ZenPure - Q-Test

Your Local Distributor:

ZenPure

A9.7 Rev 2011.08

SKV Series PES Filter Capsules

ZenPure

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

SPECIFICATIONS (cont.) Bacterial Retention:

Complete retention of > 107organisms/cm2 of Brevundimonas diminuta in accordance with the current HIMA challenge methodology (ASTM F838-83). Validation Guide upon request.

Autoclavable & Sanitizable: Capsules can be autoclaved 25 times at 257°F/125°C for 30 minutes or chemically sanitized in situ using common sanitizing agents or hot water at 194°F/90°C for a limited time (dependent on time and temperature). Cap-sules must not be in situ steam-sterilized.

Water Bubble Point Specification: 0.1um: 23psi, 0.16 MPa (IPA) 0.2um: 50psi, 0.34 MPa

Bacterial Endotoxin: Effluent is non-pyrogenic per USP Bacterial Endotoxin (0.25 EU/ml), deter-mined using Limulus Amebocyte Lysate (LAL) Test.

0

5

10

15

0

0 2

0.4

0 6

0 8

1

0 0.5 1 1.5 2 2.5 3

0 2 4 6 8 10

PureFlo Mini PES (1.5" - H) Capsule

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

0.1

0.2

1.5 Tri Clamp f ttings

0

2

4

6

8

10

0

0 08

0.16

0 24

0 32

0.4

0.48

0 56

0 64

0 0 5 1 1.5 2 2.5 3 3.5 4

0 5 10 15

PureFlo Mini PES (2.5" - S) Capsule

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

0.1

0.2

1.5 Tri Clamp f ttings

0

2

4

6

8

10

0

0 08

0.16

0 24

0 32

0.4

0.48

0 56

0 64

0 0 5 1 1.5 2 2.5 3 3.5 4

0 5 10 15

PureFlo Mini PES (5" - L) Capsule

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

0.1

0.2

1.5 Tri Clamp f ttings

Note - Graphs based on Sanitary fittings.

PureFlo Capsule

FiltersFilter Media

Pore size

(Micron)

Internal

Filter

Length

SKV S = PES 004 = 0 04 H = 1.5" 1H = 1/8" Hose Barbs 1H = 1/8" Hose Barbs O-Ring for Quick

010 = 0.1 S = 2.5" 1NF = 1/8" FNPT 1NF = 1/8" FNPT -OE = O-ring EPDM020 = 0 2 L = 5" 1Q = 1/8" Male Quick Coupling with Metal Latch 1Q = 1/8" Male Quick Coupling with Metal Latch -ON = O-ring Nitrile045 = 0.45 E = 7.5" 1QF = 1/8" Female Quick Coupling with Metal Latch 1QF = 1/8" Female Quick Coupling with Metal Latch -OV = O-ring Viton065 = 0 65 K = 10" 2H = 1/4" Hose Barbs 2H = 1/4" Hose Barbs080 = 0 8 2N = 1/4" MNPT 2N = 1/4" MNPT120 = 1 2 2NF = 1/4" FNPT 2NF = 1/4" FNPT

2Q = 1/4" Male Quick Coupling for Metal Latch 2Q = 1/4" Male Quick Coupling for Metal Latch -FB = Filling Bell*2QF = 1/4" Female Quick Coupling with Metal Latch 2QF = 1/4" Female Quick Coupling with Metal Latch -FC = Filling Bell with Cap*2QFP = 1/4" Female Quick Coupling w/Plastic Latch 2QFP = 1/4" Female Quick Coupling w/Plastic Latch2QP = 1/4" Male Quick Coupling for Plastic Latch 2QP = 1/4" Male Quick Coupling for Plastic Latch3H = 3/8" Hose Barb 3H = 3/8" Hose Barb 3NF = 3/8" FNPT 3NF = 3/8" FNPT4H = 1/2" Hose Barb 4H = 1/2" Hose Barb 4N = 1/2" MNPT 4N = 1/2" MNPT4QP = 1/2" Male Quick Coupling for Plastic latch 4QP = 1/2" Male Quick Coupling for Plastic latchMT = 1/2" Tri-clamps MT = 1/2" Tri-clampsTC = 1-1/2" Tri-clamp TC = 1-1/2" Tri-clamp

-NI = No vent or drain inlet fitting Silicon O-Rings for Bleed

Valve and Quick Coupling fittings

-NO = No vent or drain Outlet fitting

Example - PureFlo SKV Series Capsule, PES , 2.5" internal filter, 0.2 micron, with 1 5" Tri-Clamp fittings I/O, w/PP Construction, would be SKVS020STCTC

Note Quick Couplings are molded on. Female Quick Coupling with Plastic latch will be threaded on. Compatible with CPC (Colder), LinkTech and others. * - 2H or 3H with fil ing bell only

Option

Blank = Polypro construction

-E = Polyethylene shell and HDPE media support for gamma sterilization

-GP = Gamma stable polypropylene shell -G(pore Size)= Glass Fiber

PreFilter

70mm Diameter Capsule with Bleed

Valve

-P(pore Size)= PolyPro Media PreFilter-ETO = Ethylene oxide

sterilization -S(pore Size) = PES PreFilter-N= No vent or drain

fittings

Input Fitting

Blank = O-ring Silicon (Standard)

Output Fitting

PureFlo SKV Series PES Filter Capsule (Pharmaceutical grade) Ordering Guide

Page 33

Page 35: ZenPure - Q-Test

SKV Series PES Filter Capsules

(PES/PE Construction)

ZenPure Z

en

Pu

re

Pharmaceutical Capsule filter

The PureFlo® SKV Series PES filter capsule with all-polyethylene (PE) construction provides excellent chemical compatibility and superior flow per unit area as compared to other membrane capsules. These PureFlo® PES filter cap-sules with Polyethylene construction have been specially designed to be gamma sterilized for biopharmaceutical applications. The PES and the PE construction are naturally Gamma radiation staple. The hydrophilic PES membrane does not require pre-wetting agents, thereby eliminating a potential source of contamination. The PES membrane is a low protein-binding media.

The capsules were designed with built-in bleed valves for simple and efficient evacuation of air and liquid. The units are used for filtration of small to medium volumes used in production, laboratory and pilot runs. No adhesives, binders, or surfactants are used in the manufacturing process of these capsules. They are rinsed with pyrogen-free water to reduce extractables and downtime. All filter capsules are 100% integrity-tested to ensure filter performance each and every time out of the package. PureFlo SKV Series PES filter capsules are well-suited for pharmaceutical applications where gamma sterilization is needed.

Applications

Buffers and Media Fermentation Broths

Product Sterilization SVP (Small Volume Par-

enterals)

Bio Bags Pharmaceuticals

Vaccines Biologics

Antibiotics Scale up processing

Water Serums

Specifications

Materials of Construction: Media: PES (Polyethersulfone) Media Supports: High Density Polyethylene (HDPE) Cage, Core, End Caps: HDPE Valve O-Rings: Silicon (Standard); Sealing: Thermally welded

Fitting Connections: See ordering guide for the availability. Any inlet/outlet combinations. (Custom adaptors available upon request)

Nominal Dimensions: Lengths: 1.5 in (68mm), 2.5 in (98mm), 5.0 in (153mm), 7.5 in (251mm), 10 in (281mm)

Diameter: 2.88 in (73 mm)

Effective Filtration Area: 1.5in: 0.77 ft2 (720 cm2), 2.5in: 1.48 ft2 (1380 cm2), 5.0in: 2.8 ft2 (2600 cm2), 7.5in: 4.3ft2 (3980cm2), 10in: 5.6 ft2 (5200 cm2)

Operating Conditions: Maximum Forward Differential Pressure: Liquid: 5.5 bar (80psi) at 77°F/25°C Gas: 4.1 bar (60psi) at 77°F/25°C Minimum Burst Pressure: 8.3 bar (120psi) at 77°F/25°C Maximum Forward Differential Pressure: 5 bar (72psi) at 68°F/20°C Maximum Reverse Differential Pressure: 3.0 bar (44psi) at 68°F/20°C

Maximum Operating Temperature: 140°F/60°C

Regulatory Compliance: The filters are constructed with polypropylene resins and filtration media in compliance with 21CFR Part 177 of the US Code of Federal Regulations and USP Class VI Biological Test for Plastic.

Page 34

Page 36: ZenPure - Q-Test

Your Local Distributor:

ZenPure

A9.8 Rev 2011.08

Series PES Filter Capsules

(PES/PE Construction)

ZenPure

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

Specifications (cont.)

Bacterial Retention: Complete retention of > 107organisms/cm2 of Brevundimonas diminuta in accordance with the current HIMA challenge methodology (ASTM F838-83). Validation Guide upon request.

Sanitizable:

The filters can be Gamma sterilized up to 45kGy. The filters can also be chemically sanitized in situ using common sanitizing agents or hot water at 194°F/90°C for a limited time (dependent on time and temperature). Not Autoclavable.

Water Bubble Point Specification:

0.1um: 23psi, 0.16 MPa (IPA) 0.2um: 50psi, 0.34 MPa

Bacterial Endotoxin:

Effluent is non-pyrogenic per USP Bacterial Endotoxin (0.25 EU/ml), deter-mined using Limulus Amebocyte Lysate (LAL) Test.

0

5

10

15

0

0 2

0.4

0 6

0 8

1

0 0.5 1 1.5 2 2.5 3

0 2 4 6 8 10

PureFlo Mini PES (1.5" - H) Capsule

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

0.1

0.2

1.5 Tri Clamp f ttings

0

2

4

6

8

10

0

0 08

0.16

0 24

0 32

0.4

0.48

0 56

0 64

0 0 5 1 1.5 2 2.5 3 3.5 4

0 5 10 15

PureFlo Mini PES (2.5" - S) Capsule

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

0.1

0.2

1.5 Tri Clamp f ttings

0

2

4

6

8

10

0

0 08

0.16

0 24

0 32

0.4

0.48

0 56

0 64

0 0 5 1 1.5 2 2.5 3 3.5 4

0 5 10 15

PureFlo Mini PES (5" - L) Capsule

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

0.1

0.2

1.5 Tri Clamp f ttings

Note - Graphs based on Sanitary fittings.

PureFlo Capsule

FiltersFilter Media

Pore size

(Micron)

Internal

Filter

Length

SKV S = PES 004 = 0.04 H = 1.5" 1H = 1/8" Hose Barbs 1H = 1/8" Hose Barbs O-Ring for Quick

010 = 0.1 S = 2.5" 1NF = 1/8" FNPT 1NF = 1/8" FNPT -OE = O-ring EPDM020 = 0.2 L = 5" 1Q = 1/8" Male Quick Coupling with Metal Latch 1Q = 1/8" Male Quick Coupling with Metal Latch -ON = O-ring Nitrile045 = 0.45 E = 7.5" 1QF = 1/8" Female Quick Coupling with Metal Latch 1QF = 1/8" Female Quick Coupling with Metal Latch -OV = O-ring Viton065 = 0.65 K = 10" 2H = 1/4" Hose Barbs 2H = 1/4" Hose Barbs080 = 0.8 2N = 1/4" MNPT 2N = 1/4" MNPT120 = 1.2 2NF = 1/4" FNPT 2NF = 1/4" FNPT

2Q = 1/4" Male Quick Coupling for Metal Latch 2Q = 1/4" Male Quick Coupling for Metal Latch -FB = Filling Bell*2QF = 1/4" Female Quick Coupling with Metal Latch 2QF = 1/4" Female Quick Coupling with Metal Latch -FC = Filling Bell with Cap*2QFP = 1/4" Female Quick Coupling w/Plastic Latch 2QFP = 1/4" Female Quick Coupling w/Plastic Latch2QP = 1/4" Male Quick Coupling for Plastic Latch 2QP = 1/4" Male Quick Coupling for Plastic Latch3H = 3/8" Hose Barb 3H = 3/8" Hose Barb 3NF = 3/8" FNPT 3NF = 3/8" FNPT4H = 1/2" Hose Barb 4H = 1/2" Hose Barb 4N = 1/2" MNPT 4N = 1/2" MNPT4QP = 1/2" Male Quick Coupling for Plastic latch 4QP = 1/2" Male Quick Coupling for Plastic latchMT = 1/2" Tri-clamps MT = 1/2" Tri-clampsTC = 1-1/2" Tri-clamp TC = 1-1/2" Tri-clamp

-NI = No vent or drain inlet fitting Silicon O-Rings for Bleed

Valve and Quick Coupling fittings

-NO = No vent or drain Outlet fitting

Example - PureFlo SKV Series Capsule, PES , 2.5" internal filter, 0.2 micron, with 1.5" Tri-Clamp fittings I/O, w/PE Construction, would be SKVS020STCTC-E

Note: Quick Coup ings are molded on. Female Qu ck Coupling with Plast c latch wi l be threaded on. Compatible with CPC (Co der), LinkTech and others. * - 2H or 3H with f lling bell only

Option

Blank = Polypro construction

-E = Polyethylene shell and HDPE media support for gamma sterilization

-GP = Gamma stable polypropylene shell -G(pore Size)= Glass Fiber

PreFilter

70mm Diameter Capsule with Bleed

Valve

-P(pore Size)= PolyPro Media PreFilter-ETO = Ethylene oxide

sterilization -S(pore Size) = PES PreFilter-N= No vent or drain

fittings

Input Fitting

Blank = O-ring Silicon (Standard)

Output Fitting

PureFlo SKV Series PES Filter Capsule (Pharmaceutical grade) Ordering Guide

Page 35

Page 37: ZenPure - Q-Test

PureFlo® PES Filter Capsules

High performance encapsulated Pharmaceutical grade PES Filter

ZenPure Z

en

Pu

re

The PureFlo® PES filter capsule in its all-polypropylene

construction provides excellent chemical compatibility and

superior flow per unit area as compared to other membrane

capsules. PureFlo® PES Filter Capsules have been specially

designed for sterilizing in biopharmaceutical applications. Its

hydrophilic PES membrane does not require pre-wetting

agents, thereby eliminating a potential source of

contamination. The PES membrane is low protein-binding.

The capsules were designed for simple and efficient filtration

of small volumes used in low-flow application, laboratory, and

pilot runs. No adhesives, binders, or surfactants are used in

the manufacturing process of these capsules. They are rinsed

with pyrogen-free water to reduce extractables and downtime.

All filter capsules are 100% integrity-tested to ensure filter

performance each and every time out of the package. PureFlo

PES filter capsules are well-suited for pharmaceutical

applications where superior flow and bacterial retention is

required. The capsule can be ordered pre-sterilized.

SPECIFICATIONS

Regulatory Compliance Manufactured from materials that conform to the

requirements of 21CFR Part 177 of the U.S. Code of

Federal Regulations and USP Class VI Biological

test for Plastics

Bacterial Retention Complete retention of > 107organisms/cm2 of Bre-

vundimonas diminuta in accordance with the current

HIMA challenge methodology (ASTM F838-83).

Validation Guide upon request.

Autoclavable & Sanitizable: Capsules can be autoclaved 25 times at 257°F/125°C

for 30 minutes or chemically sanitized in situ using

common sanitizing agents or hot water at 194°F/90°C

for a limited time (dependent on time and tempera-

ture). Capsules must not be in situ steam-sterilized.

Water Bubble Point Specification 0.1um : 23psi,0.16 MPA (IPA)

0.2um : 47psi,0.32 MPa

Bacterial Endotoxin Effluent is non-Pyrogenic per USP Bacterial En-

dotoxin (0.25 EU/ml), determined using Limulus

Amebocyte Lysate (LAL) test.

Applications

Culture Media Fermentation Broths

Serums SVP (Small volume

parenterals)

Vaccines Product Sterilization

Reagents & Buffers Biologics

Antibiotics Beverages

WFI-POU Scale-up processes

Features Benefits

■ Hydrophilic PES Membrane ■ Inherently hydrophilic for cleaner filtrates

■ High flow rate reduces processing time

■ Low protein-binding membrane maximizing yields

■ Biologically inert membrane

■ Bacterial retentive to produce sterile solutions

■ Small, Compact Design ■ Simple, quick, and efficient filtration

■ Low hold-up volume reduces product waste

■ Low Filter Extractables ■ No adhesives, binders, or surfactants are used during manufacturing

resulting in superior downstream cleanliness

■ All capsules are rinsed with pyrogen-free water

SKL Capsules

Page 36

Page 38: ZenPure - Q-Test

ZenPure PureFlo® PES Filter Capsules

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

B10 Rev 2011.08

PureFlo PES Filter Capsule (Pharmaceutical grade) Ordering Guide

Materials of Construction Membrane: Hydrophilic Polyethersulfone

Membrane Supports: Polypropylene or PET

Cage, Core, End Caps: Polypropylene or

Polyethylene option

Fitting Connections

NPT, Sanitary Flange, Hose Barb, Coupling

Vent/Drain - Luer Lock, Plug, Bleed Valve

Dimensions (Nominal)

Length: 1.5 in (68 mm) Length: 2.5 in (98 mm)

Length: 5.0 in (153 mm) Length: 7.5 in (251 mm)

Length: 10 in (281mm)

Diameter: 2.88 in (73 mm)

Effective Filtration Area

1.5 in - 0.77 ft2 (720 cm2) 2.5 in - 1.48 ft2 (1380 cm2)

5.0 in - 2.8 ft2 (2600 cm2) 7.5 in - 4.3 ft2 (3980 cm2)

10 in - 5.6 ft2 (5200 cm2)

Operating Conditions Maximum Operating Pressure:

Liquid: 5.5 bar (80psi) at 77°F/25°C

Gas: 4.1 bar (60psi) at 77°F/25°C

Minimum Burst Pressure:

8.3 bar (120psi) at 77°F/25°C

Maximum Forward Differential Pressure:

5 bar (72psi) at 68°F/20°C

Maximum Reverse Differential Pressure:

2.1 bar (30psi) at 68°F/20°C

Maximum Operating Temperature:

PP & Gamma PP: 176°F/80°C

HDPE: 140°F/60°C Note - Graphs based on Sanitary fittings.

0

5

10

15

0

0.2

0.4

0.6

0.8

1

0 0.5 1 1.5 2 2.5 3

0 2 4 6 8 10

PureFlo Mini PES (1.5" - H) Capsule

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

0.1

0.2

1 5 Tri Clamp fittings

0

2

4

6

8

10

0

0.08

0.16

0.24

0.32

0.4

0.48

0.56

0.64

0 0.5 1 1.5 2 2.5 3 3.5 4

0 5 10 15

PureFlo Mini PES (2.5" - S) Capsule

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

0.1

0.2

1 5 Tri Clamp fittings

0

2

4

6

8

10

0

0.08

0.16

0.24

0.32

0.4

0.48

0.56

0.64

0 0.5 1 1.5 2 2.5 3 3.5 4

0 5 10 15

PureFlo Mini PES (5" - L) Capsule

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

0.1

0.2

1 5 Tri Clamp fittings

PureFlo

Capsule Filters

Vent & Drain

Fitting

Filter

MediaPore size (Micron) Length

004 = 0.04um H = 1.5" 1H = 1/8" Hose barbs 1H = 1/8" Hose barbs O-Ring for Quick

SK S = PES 010 = 0.1um S = 2.5" 1NF = 1/8" FNPT 1NF = 1/8" FNPT -OE = O-ring EPDM020 = 0.2um L = 5" 1Q = 1/8" Male Quick Coupling for Metal latch 1Q = 1/8" Male Quick Coupling for Metal latch -ON = O-ring Nitrile050= 0.45um E = 7.5" 1QF = 1/8" Female Quick Coupling w/ Metal latch 1QF = 1/8" Female Quick Coupling w/ Metal latch -OV = O-ring Viton065 = 0.65um K = 10" 2H = 1/4" to 1/2" Hose barbs 2H = 1/4" to 1/2" Hose barbs080 = 0.8um 2HS = 1/4" to 3/8" Hose barbs 2HS = 1/4" to 3/8" Hose barbs120 =1.2um 2LF = Large Female Luer Lock fitting 2LF = Large Female Luer Lock fitting -NY = Nylon Construction

2N = 1/4" MNPT 2N = 1/4" MNPT -FB = Filling bell2NF = 1/4" FNPT 2NF = 1/4" FNPT -FC = Filling bell with Cap2Q = 1/4" Male Quick Coupling for Metal latch 2Q = 1/4" Male Quick Coupling for Metal latch2QF = 1/4" Female Quick Coupling w/ Metal latch 2QF = 1/4" Female Quick Coupling w/ Metal latch2QFP = 1/4" Female Quick Coupling w/ Plastic latch 2QFP = 1/4" Female Quick Coupling w/ Plastic latch2QP = 1/4" Male Quick Coupling for Plastic latch 2QP = 1/4" Male Quick Coupling for Plastic latch3H = 3/8" Hose Barb 3H = 3/8" Hose Barb 3HE = 3/8" Hose Barb Elbow 3HE = 3/8" Hose Barb Elbow3NF = 3/8" FNPT 3NF = 3/8" FNPT4H = 1/2" Hose Barb 4H = 1/2" Hose Barb 4N = 1/2" MNPT 4N = 1/2" MNPT4QP = 1/2" Male Quick Coupling for Plastic latch 4QP = 1/2" Male Quick Coupling for Plastic latchMT = 1/2" Tri clamps MT = 1/2" Tri clampsTC = 1-1/2" Tri clamp TC = 1-1/2" Tri clamp

Output Fitting Options

L = Female Luer Lock

-P(pore Size)= PolyPro Media PreFilter

Input Fitting

-PH = Pharma Grade

Example - Capsule, Luer Lock V/D, 2.5" Internal filter, 0.2 micron PES Capsule, Pharma Grade, with 1.5" Tri-Clamp fittings would be SKLS020STCTC-PH

70mm Diameter Capsule

-E = Polyethylene shell and HDPE media support for gamma sterilization

Blank = O-ring Silicon (Standard)

-GP = Gamma stable polypropylene shell

P = M8 Threaded Plug - Limited options

-G(pore Size)= Glass Fiber PreFilter

-ETO = Ethylene oxide sterilization -S(pore Size) = PES

PreFilter

-NO = NO vent or drain Outlet fitting

-NI = No vent or drain inlet fitting

Quick Couplings are mo ded, Fema e Qu ck Coup ing with Plastic latch wi l be threaded on, compatible with CPC (Colder), LinkTech and others.

N = No vent or drain fittings

Page 37

Page 39: ZenPure - Q-Test

PureFlo® Biological Reduction Grade Capsules

A High performance encapsulated PES membrane filter

ZenPure Z

en

Pu

re

The PureFlo® Biological Reduction Grade filter capsule in its

all-polypropylene construction provides excellent chemical

compatibility and superior flow per unit area as compared to

other membrane capsules. PureFlo® Biological grade capsules

have been designed for bioreduction in pharmaceutical appli-

cations. Its hydrophilic PES membrane does not require pre-

wetting agents, thereby eliminating a potential source of con-

tamination. The PES membrane is low protein-binding.

The capsules were designed for simple and efficient filtration

of small volumes used in low-flow application, laboratory, and

pilot runs. No adhesives, binders, or surfactants are used in

the manufacturing process of these capsules. They are rinsed

with pyrogen-free water to reduce extractables and downtime.

All filter capsules are 100% integrity tested to ensure filter

performance each and every time out of the package. PureFlo

PES filter capsules are well-suited for pharmaceutical

applications where superior flow and bacterial retention is

required.

SPECIFICATIONS

Regulatory Compliance Manufactured from materials that conform to

the requirements of 21CFR Part 177 of the

U.S. Code of Federal Regulations and USP

Class VI Biological Test for Plastics

Autoclavable & Sanitizable Capsules can be autoclaved 25 times at 257°

F/125°C for 30 minutes or chemically sanitized in

situ using common sanitizing agents or hot water

at 90°C for a limited time (dependent on time and

temperature). Capsules must not be in situ steam-

sterilized.

Water Bubble Point Specification 0.1um : 23psi (IPA)

0.2um : 47psi

0.45um: 33psi

Bacterial Endotoxin Effluent is non-pyrogenic per USP Bacterial

Endotoxin (0.25 EU/ml), determined using

Applications

Culture media Fermentation Broths

Serums SVP (Small volume

parenterals)

Vaccines Bio Reduction

Reagents & Buffers Biologics

Antibiotics Beverages

WFI-POU Scale-up processes

Features Benefits ■ Hydrophilic PES Membrane ■ Inherently hydrophilic for cleaner filtrates

■ High flow rate reduces processing time

■ Low protein-binding membrane maximizing yields

■ Biologically inert membrane

■ Bacterial retentive to produce sterile solutions

■ Small Compact Design ■ Simple, quick, and efficient filtration

■ Low hold-up volume reduces product waste

■ Low Filter Extractables ■ No adhesives, binders, or surfactants are used during manufacturing re-

sulting in superior downstream cleanliness

■ All capsules are rinsed with pyrogen-free water

Page 38

Page 40: ZenPure - Q-Test

ZenPure PureFlo® Biological Reduction Grade Capsules

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

B10.5 Rev 2011.08

Materials of Construction Membrane: Hydrophilic Polyethersulfone

Membrane Supports: Polypropylene, or PET

Cage, Core, End Caps: Polypropylene, or Polyethylene option

Fitting Connections NPT, Sanitary Flange, Hose Barb, Couplings

Vent/Drain - Luer Lock with Cap

Dimensions (nominal) Length: 1.5 in (68 mm) Length: 2.5 in (98 mm)

Length: 5.0 in (153 mm) Length: 7.5 in (251 mm)

Length: 10 in (281mm)

Diameter: 2.88 in (73 mm)

Effective Filtration Area 1.5 in - 0.77 ft2 (720 cm2) 2.5 in - 1.48 ft2 (1380 cm2)

5.0 in - 2.8 ft2 (2600 cm2) 7.5 in - 4.3 ft2 (3980 cm2)

10 in - 5.6 ft2 (5200 cm2)

Operating Conditions Maximum Operating Pressure:

Liquid: 5.5 bar (80psi) at 77°F/25°C

Gas: 4.1 bar (60psi) at 77°F/25°C

Minimum Burst Pressure:

8.3 bar (120psi) at 77°F/25°C

Maximum Forward Differential Pressure:

4.21 bar (60psi) at 68°F/20°C

Maximum Reverse Differential Pressure:

2.1 bar (30psi) at 68°F/20°C

Maximum Operating Temperature:

PP & Gamma PP: 176°F/80°C HDPE: 140°F/60°C

0

5

10

15

0

0.2

0.4

0.6

0.8

1

0 0.5 1 1.5 2 2.5 3

0 2 4 6 8 10

PureFlo Mini PES (1.5" - H) Capsule

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

0.65

0.04

0.1

0.2

0.45

1.20.8

1.5" Tri Clamp fittings

0

2

4

6

8

10

0

0.08

0.16

0.24

0.32

0.4

0.48

0.56

0.64

0 0.5 1 1.5 2 2.5 3 3.5 4

0 5 10 15

PureFlo Mini PES (2.5" - S) Capsule

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

0.65

0.04

0.1

0.2

0.45

1.20.8

1.5" Tri Clamp fittings

0

2

4

6

8

10

0

0.08

0.16

0.24

0.32

0.4

0.48

0.56

0.64

0 0.5 1 1.5 2 2.5 3 3.5 4

0 5 10 15

PureFlo Mini PES (5" - L) Capsule

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

0.65

0.04

0.1

0.2

0.45

1.20.8

1.5" Tri Clamp fittings

Note - Graphs based on Sanitary fittings.

PureFlo

Capsule Filters

Vent & Drain

Fitting

Filter

Media

Pore size

(Micron)Length

004 = 0.04um H = 1.5" 1H = 1/8" Hose barbs 1H = 1/8" Hose barbs O-Ring for Quick

SK S = PES 010 = 0.1um S = 2.5" 1NF = 1/8" FNPT 1NF = 1/8" FNPT -OE = O-ring EPDM020 = 0.2um L = 5" 1Q = 1/8" Male Quick Coupling for Metal latch 1Q = 1/8" Male Quick Coupling for Metal latch -ON = O-ring Nitrile050= 0.45um E = 7.5" 1QF = 1/8" Female Quick Coupling w/ Metal latch 1QF = 1/8" Female Quick Coupling w/ Metal latch -OV = O-ring Viton065 = 0.65um K = 10" 2H = 1/4" to 1/2" Hose barbs 2H = 1/4" to 1/2" Hose barbs080 = 0.8um 2HS = 1/4" to 3/8" Hose barbs 2HS = 1/4" to 3/8" Hose barbs120 =1.2um 2LF = Large Female Luer Lock fitting 2LF = Large Female Luer Lock fitting -NY = Nylon Construction

2N = 1/4" MNPT 2N = 1/4" MNPT -FB = Filling bell2NF = 1/4" FNPT 2NF = 1/4" FNPT -FC = Filling bell with Cap2Q = 1/4" Male Quick Coupling for Metal latch 2Q = 1/4" Male Quick Coupling for Metal latch2QF = 1/4" Female Quick Coupling w/ Metal latch 2QF = 1/4" Female Quick Coupling w/ Metal latch2QFP = 1/4" Female Quick Coupling w/ Plastic latch 2QFP = 1/4" Female Quick Coupling w/ Plastic latch2QP = 1/4" Male Quick Coupling for Plastic latch 2QP = 1/4" Male Quick Coupling for Plastic latch3H = 3/8" Hose Barb 3H = 3/8" Hose Barb 3HE = 3/8" Hose Barb Elbow 3HE = 3/8" Hose Barb Elbow3NF = 3/8" FNPT 3NF = 3/8" FNPT4H = 1/2" Hose Barb 4H = 1/2" Hose Barb 4N = 1/2" MNPT 4N = 1/2" MNPT4QP = 1/2" Male Quick Coupling for Plastic latch 4QP = 1/2" Male Quick Coupling for Plastic latchMT = 1/2" Tri clamps MT = 1/2" Tri clampsTC = 1-1/2" Tri clamp TC = 1-1/2" Tri clamp

-E = Polyethylene shell and HDPE media support for gamma sterilization

Example - Capsule, Luer Lock V/D, 2.5" Internal filter, 0.2 micron PES Capsule, Biological Reduction Grade, with 1.5" Tri-Clamp fittings would be SKLS020STCTC-B

Quick Couplings are molded Female Quick Coupling with Plastic latch wi l be threaded on compatible with CPC (Colder) LinkTech and others.

70mm Diameter Capsule -GP = Gamma stable

polypropylene shellBlank = O-ring Silicon (Standard)N = No vent or

drain fittings -G(pore Size)= Glass Fiber PreFilter

-P(pore Size)= PolyPro Media PreFilter-ETO = Ethylene oxide

sterilization -S(pore Size) = PES PreFilter

Input Fitting Output Fitting Options

L = Female Luer Lock -B = Biological Reduction

GradeP = M8 Threaded Plug - Limited options

-NI = No vent or drain inlet fitting

-NO = NO vent or drain Outlet fitting

PureFlo PES Filter Capsule (Biological Grade) Ordering Guide

Page 39

Page 41: ZenPure - Q-Test

PureFlo® PES Filter Capsules

ZenPure Z

en

Pu

re

PureFlo® PES Filter Capsules have been specially designed

for simple, quick, and efficient filtration of fluids and gases

used in laboratory, pilot, and small-scale applications. The

PES membrane in an all-polypropylene construction provides

excellent chemical compatibility and superior flow per unit

area as compared to other membrane cartridges. No adhesives,

binders, or surfactants are used in the manufacturing process

and all capsules are rinsed with high-purity water to reduce

extractables and downtime.

The hydrophilic PES membrane does not require pre-wetting with

IPA and flushing with DI water, thereby eliminating a potential

source of contamination and hazardous waste. In addition, unlike

hydrophobic filters such as PTFE the hydrophilic membrane reduces

the potential for bubble formation by not de-wetting in out-gassing

fluids.. All filter capsules are 100% integrity tested to ensure filter

performance each and every time out of the package. PureFlo PES

filter capsules are well-suited for applications where superior flow

and particle removal efficiency at 0.04, 0.1, 0.2, 0.45, 0.65, 0.80 and

1.2 micron is required.

Materials of Construction Membrane: Hydrophilic Polyethersulfone

Membrane Supports: Polypropylene

Cage, Core, End Caps: Polypropylene

Fitting Connections: NPT, Compression, Sanitary Flange, Hose Barb

Nominal Dimensions Length: 1.5 in (68 mm) Length: 2.5 in (98 mm)

Length: 5.0 in (153 mm) Length: 7.5 in (251 mm)

Length: 10 in (281mm)

Diameter: 2.88 in (73 mm)

Effective Filtration Area 1.5 in 0.77 ft2 (720 cm2) 2.5 in 1.48 ft2 (1380 cm2)

5.0 in 2.8 ft2 (2600 cm2) 7.5 in 4.3 ft2 (3980 cm2)

10 in - 5.6 ft2 (5200 cm2)

Operating Conditions Maximum Operating Pressure:

Liquid: 5.5 bar (80psi) at 77°F/25°C

Gas: 4.1 bar (60psi) at 77°F/25°C

Minimum Burst Pressure:

8.3 bar (120psi) at 77°F/25°C

Maximum Forward Differential Pressure:

5 bar (72psi) at 68°F/20°C

Maximum Reverse Differential Pressure:

2.1 bar (30psi) at 68°F/20°C

Maximum Operating Temperature:

PP & Gamma PP: 176°F/80°C

HDPE: 140°F/60°C

Autoclavable & Sanitizable Capsules can be autoclaved 25 times at 257°F/125°C for 30 minutes

or chemically sanitized in situ using common sanitizing agents or hot

water at 194°F/90°C for a limited time (dependent on time and tem-

perature). Capsules must not be in situ steam-sterilized.

Applications

Acids Ink Jets

Bases Beverages

Solvents Pharmaceuticals

Fine Chemicals Biologics

Plating Solutions Dyes

Process Water Lacquers

Features Benefits

■ Hydrophilic PES Membrane ■ IPA pre-wetting not required – thereby eliminating a potential source of

contamination and disposal waste

■ Economic alternative to PTFE

■ Fully Disposable Capsule ■ Rapid installation

■ Reduced downtime

■ Reduced handling of hazardous chemicals

■ Small Compact Design ■ Simple, quick, and efficient filtration

■ Low hold-up volume reduces the chemical waste

■ Reduced chemical handling and hazardous waste disposal

■ Low Filter Extractables ■ No adhesives, binders, or surfactants used

■ Capsules are rinsed with high-purity water

Regulatory Compliance Manufactured from materials that conform to the require-

ments of 21CFR Part 177 of the U.S. Code of Federal Regu-

lations and USP Class VI Biological Test for Plastics.

Page 40

Page 42: ZenPure - Q-Test

ZenPure PureFlo® PES Filter Capsules

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

B11 Rev 2011.08

PureFlo PES Filter Capsule Ordering Guide

Note - Graphs based on Sanitary fittings.

1H = 1/8" Hose barbs Luer Lock1NF = 1/8" FNPT Luer Lock2C = 1/4" Compression 1/4" Comp2H = 1/4" to 1/2" Hose barbs Luer Lock2HS = 1/4" to 3/8" Hose barbs Luer Lock2L = Large Female Luer Lock fitting Luer Lock2N = 1/4" MNPT Luer Lock2NF = 1/4" FNPT Luer Lock2Q = 1/4" Male Quick Coupling Luer Lock2QF = 1/4" Female Quick Coupling Luer Lock2QFP = 1/4" Female Quick Coupling with Plastic latch Luer Lock2QP = 1/4" Male Quick Coupling for Plastic latch Luer Lock3C = 3/8" Compression 1/4" Comp3H = 3/8" Hose Barb (future) Luer Lock3HE = 3/8" Hose Barb Elbow Luer Lock3NF = 3/8" FNPT Luer Lock4C = 1/2" Commpression 1/4" Comp4H = 1/2" Hose Barb (future) Luer Lock4N = 1/2" MNPT Luer Lock4QP = 1/2" Male Quick Coupling for Plastic latch Luer LockMT = 0.5" Tri clamps Luer LockTC = 1-1/2" Tri clamp Luer Lock

Inlet/Outlet Fittings

Vent and

Drain

fittings

Option: Plugged and Cut off Vent and/or Drains

0

1

2

3

4

5

6

7

8

0

0.1

0.2

0.3

0.4

0.5

0 0.5 1 1.5 2 2.5 3

0 2 4 6 8 10

PureFlo 1.5" PES Capsule

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

1.5" Tri Clamp fitting

0.040.1

0.2

0.45

0.65

1.2

0.8

0

1

2

3

4

5

0

0.04

0.08

0.12

0.16

0.2

0.24

0.28

0.32

0 0.5 1 1.5 2 2.5 3

0 2 4 6 8 10

PureFlo 2.5" PES Capsule

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

1.5" Tri Clamp fitting

0.040.1

0.20.45

0.65

1.20.8

0

0.5

1

1.5

2

2.5

3

0

0.05

0.1

0.15

0.2

0 0.5 1 1.5 2 2.5 3

0 2 4 6 8 10

PureFlo 5.0" PES Capsule

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

1.5" Tri Clamp fitting

0.040.1

0.20.45

0.65

1.20.8

PureFlo

Capsule

Filters

Vent & Drain

FittingFilter Media

Pore size

(Micron)Length

004 = 0.04um H = 1.5" 1H = 1/8" Hose barbs 1H = 1/8" Hose barbsSK S = PES 010 = 0.1um S = 2.5" 1NF = 1/8" FNPT 1NF = 1/8" FNPT

020 = 0.2um L = 5" 1Q = 1/8" Male Quick Coupling for Metal latch 1Q = 1/8" Male Quick Coupling for Metal latch -NY = Nylon Construction -OE = O-ring EPDM050= 0.45um E= 7.5" 1QF = 1/8" Female Quick Coupling w/ Metal latch 1QF = 1/8" Female Quick Coupling w/ Metal latch -FB = Filling bell -ON = O-ring Nitrile065 = 0.65um K = 10" 2H = 1/4" to 1/2" Hose barbs 2H = 1/4" to 1/2" Hose barbs -FC = Filling bell with Cap -OV = O-ring Viton080 = 0.8um 2HS = 1/4" to 3/8" Hose barbs 2HS = 1/4" to 3/8" Hose barbs120 =1.2um 2LF = Large Female Luer Lock fitting 2LF = Large Female Luer Lock fitting

2N = 1/4" MNPT 2N = 1/4" MNPT2NF = 1/4" FNPT 2NF = 1/4" FNPT2Q = 1/4" Male Quick Coupling for Metal latch 2Q = 1/4" Male Quick Coupling for Metal latch2QF = 1/4" Female Quick Coupling w/ Metal latch 2QF = 1/4" Female Quick Coupling w/ Metal latch2QFP = 1/4" Female Quick Coupling w/ Plastic latch 2QFP = 1/4" Female Quick Coupling w/ Plastic latch2QP = 1/4" Male Quick Coupling for Plastic latch 2QP = 1/4" Male Quick Coupling for Plastic latch3H = 3/8" Hose Barb 3H = 3/8" Hose Barb 3HE = 3/8" Hose Barb Elbow 3HE = 3/8" Hose Barb Elbow3NF = 3/8" FNPT 3NF = 3/8" FNPT4H = 1/2" Hose Barb 4H = 1/2" Hose Barb 4N = 1/2" MNPT 4N = 1/2" MNPT4QP = 1/2" Male Quick Coupling for Plastic latch 4QP = 1/2" Male Quick Coupling for Plastic latchMT = 1/2" Tri clamps MT = 1/2" Tri clampsTC = 1-1/2" Tri clamp TC = 1-1/2" Tri clamp

P = M8 Threaded Plug - Limited options

70mm Diameter Capsule

-S(pore Size) = PES PreFilter

Input Fitting Output Fitting Options

L = Female Luer Lock

-G(pore Size)= Glass Fiber PreFilter

N = No vent or drain fittings

-NO = NO vent or drain Outlet fitting

Blank = O-ring Silicon (Standard)

-P(pore Size)= PolyPro Media PreFilter

Example - Capsule, Luer Lock V/D, 2.5" Internal filter, 0.2 micron PES Capsule, Standard Grade, with 1.5" Tri-Clamp fittings would be SKLS020STCTC

Quick Couplings are molded, Female Quick Coupling with Plastic latch will be threaded on, compatible with CPC (Colder), LinkTech and others.

-GP = Gamma stable polypropylene shell

-ETO = Ethylene oxide sterilization

-NI = No vent or drain inlet fitting

-E = Polyethylene shell and HDPE media support for gamma sterilization

O-Ring for Quick

Coupling

PreFilters

Page 41

Page 43: ZenPure - Q-Test

SKV Series PTFE Filter Capsules

(PTFE/ PP Construction)

ZenPure Z

en

Pu

re

Pharmaceutical Capsule filter

The PureFlo® SKV Series PTFE filter capsule with all-polypropylene or polyethylene construction provides a excellent compatibility and superior flow per unit area. The SKV capsules were designed with built-in bleed valves for simple and efficient evacuation of air and liquid from the upstream side.

The hydrophobic PTFE membrane is ideally suited for sterilizing in biopharmaceutical applications in aggres-sive chemicals, air and gas. In addition, the hydropho-bic membrane provides superior flow and pressure-drop characteristics for tank venting applications. PureFlo PTFE filter capsules are well-suited for critical applications where superior flow and bacterial reten-tion is required.

The units are used for filtration of small to medium volumes used in production, laboratory and pilot runs. No adhesives, binders, or surfactants are used in the manufacturing process of these capsules. They are rinsed with pyrogen-free water to reduce extractables and downtime. All filter capsules are 100% integrity-tested to ensure filter performance each and every time out of the package. The capsule can be ordered pre-sterilized.

Applications Buffer and Media Fermentation Tanks

Product Sterilization SVP (Small Volume

Parenterals)

Bio Bags Pharmaceuticals

Gas filtration Biologics

Antibiotics Venting

Water Serums

Specifications

Materials of Construction: Media: Hydrophobic PTFE (polytetrafluoroethylene) Media Supports: Polypropylene Cage, Core, End Caps: Polypropylene Valve O-Rings: Silicon (Standard); Sealing: Thermally welded

Fitting Connections: See ordering guide for the availability. Any inlet/outlet combinations. (Custom adaptors available upon request)

Nominal Dimensions: Lengths: 1.5 in (68 mm), 2.5 in (98 mm),5.0 in (153mm), 7.5 in (251 mm), 10 in (281mm) Diameter: 2.88 in (73 mm)

Effective Filtration Area: 1.5 in - 0.77 ft2 (650 cm2), 2.5 in - 1.48 ft2 (1250 cm2), 5.0 in - 2.8 ft2 (2400 cm2), 7.5 in - 4.3ft2 (3980 cm2), 10 in - 5.6 ft2 (4800 cm2)

Operating Conditions: Maximum Operating Pressure: Liquid: 5.5 bar (80psi) at 77°F/25°C Gas: 4.1 bar (60psi) at 77°F/25°C Maximum Forward Differential Pressure: 5.0 bar (72psi) at 68°F/20°C Maximum Reverse Differential Pressure: 3.0 bar (44 psi) at 68°F/20°C Minimum Burst Pressure: 8.3 bar (120psi) at 77°F/25°C

Maximum Operating Temperature: PP & Gamma PP: 176°F/80°C HDPE: 140°F/60°C

Regulatory Compliance: The filters are constructed with polypropylene resins and filtration media in compliance with 21CFR Part 177 of the US Code of Federal Regulations and USP Class VI Biological Test for Plastic.

Page 42

Page 44: ZenPure - Q-Test

Your Local Distributor:

ZenPure

B11.5 Rev 2011.08

SKV Series PTFE Filter Capsules

ZenPure

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

Specifications(continued)

Bacterial Retention (for 0.2um membrane):

Complete retention of > 107organisms/cm2 of Brevundimonas diminuta in accordance with the current HIMA challenge methodology (ASTM F838-83). Validation Guide upon request.

Autoclavable & Sanitizable: Capsules can be autoclaved 25 times at 257°F/125°C for 30 minutes or chemically sanitized in situ using common sanitizing agents or hot water at 194°F/90°C for a limited time (dependent on time and temperature). Capsules must not be in situ steam-sterilized.

Bacterial Endotoxin:

Effluent is non-pyrogenic per USP Bacterial Endotoxin (0.25 EU/ml), deter-mined using Limulus Amebocyte Lysate (LAL) Test.

Note - Graphs based on Sanitary fittings.

PureFlo Capsule

FiltersFilter Media

Pore size

(Micron)

Internal

Filter

Length

SKV F = PTFE 010 = 0.1 H = 1.5" 1H = 1/8" Hose Barbs 1H = 1/8" Hose Barbs O-Ring for Quick

020 = 0.2 S = 2.5" 1NF = 1/8" FNPT 1NF = 1/8" FNPT -OE = O-ring EPDM045 = 0.45 L = 5" 1Q = 1/8" Male Quick Coupling with Metal Latch 1Q = 1/8" Male Quick Coupling with Metal Latch -ON = O-ring Nitrile100 = 1.0 E = 7.5" 1QF = 1/8" Female Quick Coupling with Metal Latch 1QF = 1/8" Female Quick Coupling with Metal Latch -OV = O-ring Viton300 = 3.0 K = 10" 2H = 1/4" Hose Barbs 2H = 1/4" Hose Barbs500 = 5.0 2N = 1/4" MNPT 2N = 1/4" MNPT999 = 10.0 2NF = 1/4" FNPT 2NF = 1/4" FNPT

2Q = 1/4" Male Quick Coupling for Metal Latch 2Q = 1/4" Male Quick Coupling for Metal Latch -FB = Filling Bell*2QF = 1/4" Female Quick Coupling with Metal Latch 2QF = 1/4" Female Quick Coupling with Metal Latch -FC = Filling Bell with Cap*2QFP = 1/4" Female Quick Coupling w/Plastic Latch 2QFP = 1/4" Female Quick Coupling w/Plastic Latch2QP = 1/4" Male Quick Coupling for Plastic Latch 2QP = 1/4" Male Quick Coupling for Plastic Latch3H = 3/8" Hose Barb 3H = 3/8" Hose Barb 3NF = 3/8" FNPT 3NF = 3/8" FNPT4H = 1/2" Hose Barb 4H = 1/2" Hose Barb 4N = 1/2" MNPT 4N = 1/2" MNPT4QP = 1/2" Male Quick Coupling for Plastic latch 4QP = 1/2" Male Quick Coupling for Plastic latchMT = 1/2" Tri-clamps MT = 1/2" Tri-clampsTC = 1-1/2" Tri-clamp TC = 1-1/2" Tri-clamp

Example - PureFlo SKV Series Capsule, PTFE , 2.5" internal filter, 0.2 micron, with 1.5" Tri-Clamp fittings I/O, w/PP Construction, would be SKVF020STCTC

Note Quick Couplings are molded on. Female Quick Coup ing with Plastic latch will be threaded on. Compatible with CPC (Colder) LinkTech and others. * - 2H or 3H with filling bell only

-P(pore Size)= PolyPro Media PreFilter-ETO = Ethylene oxide

sterilization -S(pore Size) = PES PreFilter-N= No vent or drain

fittings

-NI = No vent or drain inlet fitting Silicon O-Rings for Bleed

Valve and Quick Coupling fittings

-NO = No vent or drain Outlet fitting

Input Fitting Output Fitting Option

Blank = Polypro construction

70mm Diameter Capsule with Bleed

Valve

-E = Polyethylene shell and HDPE media support for gamma sterilization

Blank = O-ring Silicon (Standard)-GP = Gamma stable

polypropylene shell -G(pore Size)= Glass Fiber PreFilter

PureFlo SKV Series PTFE Filter Capsule (Pharmaceutical grade) Ordering Guide

0

2

4

6

8

10

0

0.08

0.16

0.24

0.32

0.4

0.48

0.56

0.64

0 0.5 1 1.5 2 2.5 3

0 2 4 6 8 10

PureFlo 1.5" PTFE Capsule

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

1.5" Tri Clamp fitting

0.1 0.2 0.45

1.0

0

2

4

6

8

10

0

0.08

0.16

0.24

0.32

0.4

0.48

0.56

0.64

0 0.5 1 1.5 2 2.5 3

0 2 4 6 8 10

PureFlo 2.5" PTFE Capsule

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

1.5" Tri Clamp fitting

0.1 0.2

0.45

1.0

0

2

4

6

8

10

0

0.08

0.16

0.24

0.32

0.4

0.48

0.56

0.64

0 0.5 1 1.5 2 2.5 3

0 2 4 6 8 10

PureFlo 5.0" PTFE Capsule

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

1.5" Tri Clamp fitting

0.1

0.2

0.45

1.0

Page 43

Page 45: ZenPure - Q-Test

PureFlo® PTFE Filter Capsules

ZenPure Z

en

Pu

re

PureFlo® PTFE filter capsules are highly retentive

hydrophobic PTFE membrane filters that have been specially

designed for critical applications. The PTFE membrane in an

all-polypropylene construction provides excellent chemical

compatibility and superior flow per unit area as compared to

other membrane capsules. No adhesives, binders, or surfac-

tants are used in the manufacturing process.

The hydrophobic PTFE membrane is ideally suited for

aggressive chemicals such as acids, bases, and solvents. In

addition, the hydrophobic membrane provides superior flow

and pressure-drop characteristics per unit area for gas filtration

and tank venting applications. All filter capsules are 100%

integrity tested to ensure filter performance each and every

time out of the package. PureFlo PTFE filter capsules are well

-suited for critical applications where superior flow and parti-

cle removal efficiency at 0.1 to 10.0 micron is required.

Applications

Acids Ink Jets

Bases Electronics

Solvents Pharmaceuticals

Fine Chemicals Venting

Plating Solutions Dyes

Process Water Lacquers

Features Benefits

■ Naturally Hydrophobic PTFE Membrane ■ High flow rates with low pressure drop per unit area as com-

pared to other filter materials

■ Superior filter lifetime and process throughputs

■ Wide Chemical & Thermal Compatibility ■ Provides excellent compatibility with a wide-range of

chemicals such as acids, bases, and solvents

■ No media migration into the process fluid

■ Low Filter Extractables ■ No adhesives, binders, or surfactants are used during the manufacturing process resulting in superior downstream

cleanliness

■ All cartridges are rinsed with high-purity water to reduce

extractables and downtime

■ Quality Manufacturing ■ Consistent and reproducible particulate removal

Regulatory Compliance Manufactured from materials that conform to the require-ments of 21CFR Part 177 of the U.S. Code of Federal Regu-lations and USP Class VI Biological Test for Plastic.

Autoclave Cycles

25 times @ 257°F/125°C for 30 minutes

Capsules must not be in situ steam-sterilized

Materials of Construction Membrane: Hydrophobic PTFE

Membrane Supports: Polypropylene

Cage, Core, End Caps, Capsule: Polypropylene

Fitting Connections: MNPT, FNPT, Quick Couplings,

Compression, Hose Barb, Sanitary Flange

Dimensions (Nominal) Length: 1.5 in (68 mm) Length: 2.5 in (98 mm)

Length: 5.0 in (153 mm) Length 7.5 in (251 mm)

Length: 10 in (281mm)

Diameter: 2.88 in (73 mm)

Effective Filtration Area 1.5 in - 0.65 ft2 (650 cm2) 2.5 in - 1.3 ft2 (1250 cm2)

5.0 in - 2.7 ft2 (2400 cm2) 7.5 in - 4.3ft2 (3980 cm2)

10 in - 5.2 ft2 (4800 cm2)

Operating Conditions Maximum Operating Pressure:

Liquid: 5.5 bar (80psi) at 77°F/25°C

Gas: 4.1 bar (60psi) at 77°F/25°C

Minimum Burst Pressure: 8.3 bar (120psi) at 77°F/25°C

Maximum Forward Differential Pressure:

4.21 bar (60psi) at 68°F/20°C

Maximum Reverse Differential Pressure:

2.1 bar (30psi) at 68°F/20°C

Maximum Operating Temperature:

PP & Gamma PP: 176°F/80°C HDPE: 140°F/60°C

Page 44

Page 46: ZenPure - Q-Test

ZenPure PureFlo® PTFE Filter Capsules

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

B12 Rev 2011.08

PureFlo PTFE Filter Cartridge Ordering Guide

0

2

4

6

8

10

0

0.08

0.16

0.24

0.32

0.4

0.48

0.56

0.64

0 0.5 1 1.5 2 2.5 3

0 2 4 6 8 10

PureFlo 1.5" PTFE Capsule

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

1.5" Tri Clamp fitting

0.1 0.2 0.45

1.0

0

2

4

6

8

10

0

0.08

0.16

0.24

0.32

0.4

0.48

0.56

0.64

0 0.5 1 1.5 2 2.5 3

0 2 4 6 8 10

PureFlo 2.5" PTFE Capsule

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

1.5" Tri Clamp fitting

0.1 0.2

0.45

1.0

0

2

4

6

8

10

0

0.08

0.16

0.24

0.32

0.4

0.48

0.56

0.64

0 0.5 1 1.5 2 2.5 3

0 2 4 6 8 10

PureFlo 5.0" PTFE Capsule

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

1.5" Tri Clamp fitting

0.1

0.2

0.45

1.0

Note - Graphs based on Sanitary fittings.

1H = 1/8" Hose barbs Luer Lock1NF = 1/8" FNPT Luer Lock2C = 1/4" Compression 1/4" Comp2H = 1/4" to 1/2" Hose barbs Luer Lock2HS = 1/4" to 3/8" Hose barbs Luer Lock2L = Large Female Luer Lock fitting Luer Lock2N = 1/4" MNPT Luer Lock2NF = 1/4" FNPT Luer Lock2Q = 1/4" Male Quick Coupling Luer Lock2QF = 1/4" Female Quick Coupling Luer Lock2QFP = 1/4" Female Quick Coupling with Plastic latch Luer Lock2QP = 1/4" Male Quick Coupling for Plastic latch Luer Lock3C = 3/8" Compression 1/4" Comp3H = 3/8" Hose Barb (future) Luer Lock3HE = 3/8" Hose Barb Elbow Luer Lock3NF = 3/8" FNPT Luer Lock4C = 1/2" Commpression 1/4" Comp4H = 1/2" Hose Barb (future) Luer Lock4N = 1/2" MNPT Luer Lock4QP = 1/2" Male Quick Coupling for Plastic latch Luer LockMT = 0 5" Tri clamps Luer LockTC = 1-1/2" Tri clamp Luer Lock

Inlet/Outlet Fittings

Vent and

Drain

fittings

Option: Plugged and Cut off Vent and/or Drains

PureFlo

Capsule

Filters

Vent & Drain

Fitting

Filter

Media

Pore size

(Micron)Length

010 = 0.1 H = 1.5" 1H = 1/8" Hose barbs 1H = 1/8" Hose barbsSK F = PTFE 020 = 0.2 S = 2.5" 1NF = 1/8" FNPT 1NF = 1/8" FNPT

045 = 0.45 L = 5" 1Q = 1/8" Male Quick Coupling for Metal latch 1Q = 1/8" Male Quick Coupling for Metal latch -NY = Nylon Construction -OE = O-ring EPDM100 = 1.0 E= 7.5" 1QF = 1/8" Female Quick Coupling w/Metal latch 1QF = 1/8" Female Quick Coupling w/Metal latch -FB = Filling bell -ON = O-ring Nitrile300 = 3.0 K = 10" 2H = 1/4" to 1/2" Hose barbs 2H = 1/4" to 1/2" Hose barbs -FC = Filling bell with Cap -OV = O-ring Viton500 = 5.0 2HS = 1/4" to 3/8" Hose barbs 2HS = 1/4" to 3/8" Hose barbs

N = No vent or

999 = 10.0 2LF = Large Female Luer Lock fitting 2LF = Large Female Luer Lock fitting2N = 1/4" MNPT 2N = 1/4" MNPT2NF = 1/4" FNPT 2NF = 1/4" FNPT2Q = 1/4" Male Quick Coupling for Metal latch 2Q = 1/4" Male Quick Coupling for Metal latch2QF = 1/4" Female Quick Coupling w/Metal latch 2QF = 1/4" Female Quick Coupling w/Metal latch2QFP = 1/4" Female Quick Coupling w/Plastic latch 2QFP = 1/4" Female Quick Coupling w/Plastic latch2QP = 1/4" Male Quick Coupling for Plastic latch 2QP = 1/4" Male Quick Coupling for Plastic latch3H = 3/8" Hose Barb 3H = 3/8" Hose Barb 3HE = 3/8" Hose Barb Elbow 3HE = 3/8" Hose Barb Elbow3NF = 3/8" FNPT 3NF = 3/8" FNPT4H = 1/2" Hose Barb 4H = 1/2" Hose Barb 4N = 1/2" MNPT 4N = 1/2" MNPT4QP = 1/2" Male Quick Coupling for Plastic latch 4QP = 1/2" Male Quick Coupling for Plastic latchMT = 1/2" Tri clamps MT = 1/2" Tri clampsTC = 1-1/2" Tri clamp TC = 1-1/2" Tri clamp

O-Ring for Quick

Coupling

Blank = O-ring Silicon (Standard)

PreFilters

-G(pore Size)= Glass Fiber PreFilter

-P(pore Size)= PolyPro Media PreFilter

P = M8 Threaded Plug - Limited

options

-S(pore Size) = PES PreFilter

Quick Coup ings are molded Female Quick Coupling with Plastic latch will be threaded on compatible w th CPC (Colder) LinkTech and others.

70mm Diameter Capsule -ETO = Ethylene oxide

sterilization

-NI = No vent or drain inlet fitting

-NO = NO vent or drain Outlet fitting

Input Fitting Output Fitting Options

-GP = Gamma stable polypropylene shell

-E = Polyethylene shell and HDPE media support for gamma sterilization

L = Female Luer Lock

Example - Capsule, Luer Lock V/D, 2.5" Internal filter, 0.2 micron PTFE Capsule, Standard Grade, with 1.5" Tri-Clamp fittings would be SKLF020STCTC

Page 45

Page 47: ZenPure - Q-Test

PureFlo® Nylon Filter Capsules

(Nylon Membrane on PP Construction)

ZenPure Z

en

Pu

re

PureFlo® Nylon filter capsules are highly retentive, naturally hydro-

philic nylon membrane filters that have been specially designed for

liquid applications. The nylon membrane in an all-polypropylene

construction provides excellent chemical compatibility and superior

flow per unit area as compared to other membrane capsules. No ad-

hesives, binders, or surfactants are used in the manufacturing proc-

ess. All capsules are rinsed with high-purity water to reduce ex-

tractables and downtime.

The naturally hydrophilic nylon membrane does not require pre-

wetting with IPA and flushing with DI water, thereby eliminating a

potential source of contamination and hazardous waste.

All filter capsules are 100% integrity tested to ensure filter perform-

ance each and every time out of the package. PureFlo nylon filter

capsules are well-suited for critical applications where superior flow

and particle removal efficiency at 0.05, 0.1, 0.2, 0.45, 0.65, 0.8, and

1.2 micron is required.

Applications

Solvents Parts Cleaning

Fine Chemicals Cosmetics

Ink Jets Pharmaceuticals

Process Water Biologics

Beverages Dyes

Materials of Construction Membrane: Naturally Hydrophilic Nylon

Membrane Supports: Polypropylene

Cage, Core, End Caps: Polypropylene

Fitting Connections: MNPT, FNPT, Compression, Sanitary

Flange, Hose Barb, Quick Coupling

Dimensions (Nominal) Length: 1.5 in (68 mm) Length: 2.5 in (98 mm)

Length: 5.0 in (153 mm) Length 7.5 in (251 mm)

Length: 10 in (281mm)

Diameter: 2.88 in (73 mm)

Effective Filtration Area 1.5 in - 0.74 ft2 (690 cm2) 2.5 in - 1.4 ft2 (1300 cm2)

5.0 in - 2.6ft2 (2450 cm2) 7.5 in - 4.0ft2 (3750 cm2)

10 in - 5.3 ft2 (4900 cm2)

Operating Conditions Maximum Operating Pressure:

Liquid: 5.5 bar (80psi) at 77°F/25°C

Gas: 4.1 bar (60psi) at 77°F/25°C

Minimum Burst Pressure:

8.3 bar (120psi) at 77°F/25°C

Maximum Forward Differential Pressure:

4.21 bar (60psi) at 68°F/20°C

Maximum Reverse Differential Pressure:

2.1 bar (30psi) at 68°F/20°C

Maximum Operating Temperature: 140°F/60°C

Features Benefits

■ Naturally Hydrophilic Nylon

Membrane (Absolute Rated)

■ IPA pre-wetting not required – thereby eliminating a potential source

of contamination and disposal waste

■ Reduces downtime and improves throughput

■ Economic alternative to PTFE and PVDF

■ Unlike hydrophobic filters there is no de-wetting in outgassing fluids

■ Small Disposable Capsule ■ Rapid installation reduces downtime

■ Low hold-up volume reduces chemical waste

■ Reduced handling of hazardous chemicals

■ Ease of Scale-Up ■ Consistent filtration from laboratory to full production testing

■ Low Filter Extractables ■ No adhesives, binders, or surfactants used

■ Capsules are rinsed with high-purity water

Regulatory Compliance

Manufactured from materials that conform to the require-

ments of 21CFR Part 177 of the U.S. Code of Federal Regu-

lations and USP Class VI Biological Test for Plastics.

Autoclave Cycles

25 times @ 257°F/125°C for 30 minutes

Capsules must not be in situ steam-sterilized

Page 46

Page 48: ZenPure - Q-Test

ZenPure PureFlo® Nylon Filter Capsules

(Nylon Membrane on PP Construction)

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

B13 Rev 2011.08

PureFlo Nylon Filter Cartridge Ordering Guide

0

2

4

6

8

10

0

0.08

0.16

0.24

0.32

0.4

0.48

0.56

0.64

0 0.5 1 1.5 2

0 1 2 3 4 5 6 7

PureFlo 1.5" PES Capsule

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

1/4" Commpression fitting

0.050.1

0.2

0.45 0.651.0

0

2

4

6

8

10

0

0.08

0.16

0.24

0.32

0.4

0.48

0.56

0.64

0 0.5 1 1.5 2 2.5 3

0 2 4 6 8 10

PureFlo 2.5" Nylon Capsule

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

1/4" Commpression fitting

0.050.1

0.2

0.45

0.65

1.0

0

2

4

6

8

10

0

0.08

0.16

0.24

0.32

0.4

0.48

0.56

0.64

0 1 2 3 4 5

0 4 8 12 16

PureFlo 5" Nylon Capsule

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

1/4" Commpression fitting

0.05

0.10.2

0.45

0.651.0

1H = 1/8" Hose barbs Luer Lock1NF = 1/8" FNPT Luer Lock2C = 1/4" Compression 1/4" Comp2H = 1/4" to 1/2" Hose barbs Luer Lock2HS = 1/4" to 3/8" Hose barbs Luer Lock2L = Large Female Luer Lock fitting Luer Lock2N = 1/4" MNPT Luer Lock2NF = 1/4" FNPT Luer Lock2Q = 1/4" Male Quick Coupling Luer Lock2QF = 1/4" Female Quick Coupling Luer Lock2QFP = 1/4" Female Quick Coupling with Plastic latch Luer Lock2QP = 1/4" Male Quick Coupling for Plastic latch Luer Lock3C = 3/8" Compression 1/4" Comp3H = 3/8" Hose Barb (future) Luer Lock3HE = 3/8" Hose Barb Elbow Luer Lock3NF = 3/8" FNPT Luer Lock4C = 1/2" Commpression 1/4" Comp4H = 1/2" Hose Barb (future) Luer Lock4N = 1/2" MNPT Luer Lock4QP = 1/2" Male Quick Coupling for Plastic latch Luer LockMT = 0.5" Tri clamps Luer LockTC = 1-1/2" Tri clamp Luer Lock

Inlet/Outlet Fittings

Vent and

Drain

fittings

Option: Plugged and Cut off Vent and/or Drains

PureFlo

Capsule

Filters

Vent & Drain

FittingFilter Media

Pore size

(Micron)Length

005 = 0.05 H = 1.5" 1H = 1/8" Hose barbs 1H = 1/8" Hose barbsSK N = Nylon 010 = 0.10 S = 2.5" 1NF = 1/8" FNPT 1NF = 1/8" FNPT

020 = 0.20 L = 5" 1Q = 1/8" Male Quick Coupling for Metal latch 1Q = 1/8" Male Quick Coupling for Metal latch -NY = Nylon Construction -OE = O-ring EPDM045 = 0.45 E= 7.5" 1QF = 1/8" Female Quick Coupling w/Metal latch 1QF = 1/8" Female Quick Coupling w/Metal latch -FB = Filling bell -ON = O-ring Nitrile065 = 0.65 K = 10" 2H = 1/4" to 1/2" Hose barbs 2H = 1/4" to 1/2" Hose barbs -FC = Filling bell with Cap -OV = O-ring Viton080 = 0.80 2HS = 1/4" to 3/8" Hose barbs 2HS = 1/4" to 3/8" Hose barbs120 = 1.20 2LF = Large Female Luer Lock fitting 2LF = Large Female Luer Lock fitting

2N = 1/4" MNPT 2N = 1/4" MNPT2NF = 1/4" FNPT 2NF = 1/4" FNPT2Q = 1/4" Male Quick Coupling for Metal latch 2Q = 1/4" Male Quick Coupling for Metal latch2QF = 1/4" Female Quick Coupling w/Metal latch 2QF = 1/4" Female Quick Coupling w/Metal latch2QFP = 1/4" Female Quick Coupling w/Plastic latch 2QFP = 1/4" Female Quick Coupling w/Plastic latch2QP = 1/4" Male Quick Coupling for Plastic latch 2QP = 1/4" Male Quick Coupling for Plastic latch3H = 3/8" Hose Barb 3H = 3/8" Hose Barb 3HE = 3/8" Hose Barb Elbow 3HE = 3/8" Hose Barb Elbow3NF = 3/8" FNPT 3NF = 3/8" FNPT4H = 1/2" Hose Barb 4H = 1/2" Hose Barb 4N = 1/2" MNPT 4N = 1/2" MNPT4QP = 1/2" Male Quick Coupling for Plastic latch 4QP = 1/2" Male Quick Coupling for Plastic latchMT = 1/2" Tri clamps MT = 1/2" Tri clampsTC = 1-1/2" Tri clamp TC = 1-1/2" Tri clamp

Blank = O-ring Silicon (Standard)

PreFilters

L = Female Luer Lock

-GP = Gamma stable polypropylene shell

P = M8 Threaded Plug - Limited options

70mm Diameter Capsule N = No vent or

drain fittings-ETO = Ethylene oxide sterilization

-NI = No vent or drain inlet fitting

-NO = NO vent or drain Outlet fitting

-E = Polyethylene shell and HDPE media support for gamma sterilization

Example - Capsule, Luer Lock V/D, 2.5" Internal filter, 0.2 micron Nylon Capsule, Standard Grade, with 1.5" Tri-Clamp fittings would be SKLN020STCTC

-G(pore Size)= Glass Fiber PreFilter

-P(pore Size)= PolyPro Media PreFilter

-S(pore Size) = PES PreFilter

Quick Couplings are molded Female Quick Coupling w th Plastic latch wi l be threaded on compatible with CPC (Colder) LinkTech and others.

O-Ring for Quick

Coupling

Input Fitting Output Fitting Options

Page 47

Page 49: ZenPure - Q-Test

PureFlo Nylon Filter Capsules

(SKV Series)

ZenPure Z

en

Pu

re

Nylon Capsule

PureFlo® SKV Series Nylon filter capsules are highly re-tentive, naturally hydrophilic nylon membrane filters that have been specially designed for liquid applica-tions. The nylon membrane in an all-polypropylene con-struction provides excellent chemical compatibility and superior flow per unit area as compared to other mem-brane capsules. No adhesives, binders, or surfactants are used in the manufacturing process. All capsules are rinsed with high-purity water to reduce extractables and downtime.

The naturally hydrophilic nylon membrane does not re-quire pre-wetting with IPA and flushing with DI water, thereby eliminating a potential source of contamination and hazardous waste.

All filter capsules are 100% integrity tested to ensure filter performance each and every time out of the pack-age. PureFlo nylon filter capsules are well-suited for critical applications where superior flow and particle re-moval efficiency at 0.05, 0.1, 0.2, 0.45, 0.65, 0.8 and 1.2 micron is required.

Specifications

Materials of Construction: Media: Naturally Hydrophilic Nylon Media Supports: None Cage, Core, End Caps: Polypropylene Sealing: Thermally bonded Fitting Connections: See ordering guide for the availability. (Custom adaptors available upon request) Nominal Dimensions: Length: 1.5in. (68mm), 2.5in. (98mm), 5in. (153mm), 7.5in. (251mm), and 10in. (281mm)

Diameter: 2.88 in. (73mm)

Effective Filtration Area: 1.5 in - 0.74 ft2 (690 cm2), 2.5 in - 1.4 ft2 (1300 cm2), 5.0 in - 2.64 ft2 (2450 cm2), 7.5 in - 4.0ft2 (3750 cm2), 10 in - 5.3 ft2 (4900 cm2) Operating Conditions: Maximum Operating Pressure: Liquid: 5.5 bar (80psi) at 77°F/25°C Gas: 4.1 bar (60psi) at 77°F/25°C Maximum Forward Differential Pressure: 4.2 bar (60psi) at 68°F/20°C Maximum Reverse Differential Pressure: 2.1 bar (30 psi) at 68°F/20°C Minimum Burst Pressure: 8.3 bar (120psi) at 77°F/25°C Maximum Operating Temperature: 140°F/60°C

Applications Solvents Water Hard Particle Beverages Cell Removal Pharmaceuticals Chemicals Biologics

Page 48

Page 50: ZenPure - Q-Test

ZenPure PureFlo Nylon Filter Capsules

(SKV Series)

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

B13.0.5 Rev 2011.08

Specifications (cont.)

Autoclavable & Sanitizable: Capsules can be autoclaved 25 times at 257°F/125°C for 30 minutes or chemically sanitized in situ using common sani-tizing agents or hot water at 194°F/90°C for a limited time (dependent on time and temperature). Capsules must not be in situ steam-sterilized.

Regulatory Compliance: The filters are constructed with polypropylene resins and filtration media in compliance with 21CFR Part 177 of the US Code of Federal Regulations and USP Class VI Biological Test for Plastic.

PureFlo SKV Series Nylon Filter Capsule Ordering Guide

0

2

4

6

8

10

0

0.08

0.16

0.24

0.32

0.4

0.48

0.56

0.64

0 0.5 1 1.5 2

0 1 2 3 4 5 6 7

PureFlo 1.5" PES Capsule

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

1/4" Commpression fitting

0.050.1

0.2

0.45 0.651.0

0

2

4

6

8

10

0

0.08

0.16

0.24

0.32

0.4

0.48

0.56

0.64

0 0.5 1 1.5 2 2.5 3

0 2 4 6 8 10

PureFlo 2.5" Nylon Capsule

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

1/4" Commpression fitting

0.050.1

0.2

0.45

0.65

1.0

0

2

4

6

8

10

0

0.08

0.16

0.24

0.32

0.4

0.48

0.56

0.64

0 1 2 3 4 5

0 4 8 12 16

PureFlo 5" Nylon Capsule

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

1/4" Commpression fitting

0.05

0.10.2

0.45

0.651.0

PureFlo Capsule

FiltersFilter Media

Pore size

(Micron)

Internal

Filter

Length

SKV N = Nylon 005 = 0.05 H = 1.5" 1H = 1/8" Hose Barbs 1H = 1/8" Hose Barbs O-Ring for Quick

010 = 0.1 S = 2.5" 1NF = 1/8" FNPT 1NF = 1/8" FNPT -OE = O-ring EPDM020 = 0.2 L = 5" 1Q = 1/8" Male Quick Coupling with Metal Latch 1Q = 1/8" Male Quick Coupling with Metal Latch -ON = O-ring Nitrile045 = 0.45 E = 7.5" 1QF = 1/8" Female Quick Coupling with Metal Latch 1QF = 1/8" Female Quick Coupling with Metal Latch -OV = O-ring Viton065 = 0.65 K = 10" 2H = 1/4" Hose Barbs 2H = 1/4" Hose Barbs080 = 0.8 2N = 1/4" MNPT 2N = 1/4" MNPT120 = 1.2 2NF = 1/4" FNPT 2NF = 1/4" FNPT

2Q = 1/4" Male Quick Coupling for Metal Latch 2Q = 1/4" Male Quick Coupling for Metal Latch -FB = Filling Bell*2QF = 1/4" Female Quick Coupling with Metal Latch 2QF = 1/4" Female Quick Coupling with Metal Latch -FC = Filling Bell with Cap*2QFP = 1/4" Female Quick Coupling w/Plastic Latch 2QFP = 1/4" Female Quick Coupling w/Plastic Latch2QP = 1/4" Male Quick Coupling for Plastic Latch 2QP = 1/4" Male Quick Coupling for Plastic Latch3H = 3/8" Hose Barb 3H = 3/8" Hose Barb 3NF = 3/8" FNPT 3NF = 3/8" FNPT4H = 1/2" Hose Barb 4H = 1/2" Hose Barb 4N = 1/2" MNPT 4N = 1/2" MNPT4QP = 1/2" Male Quick Coupling for Plastic latch 4QP = 1/2" Male Quick Coupling for Plastic latchMT = 1/2" Tri-clamps MT = 1/2" Tri-clampsTC = 1-1/2" Tri-clamp TC = 1-1/2" Tri-clamp

-P(pore Size)= PolyPro Media PreFilter-ETO = Ethylene oxide

sterilization -S(pore Size) = PES PreFilter-N= No vent or drain

fittings

Input Fitting

Blank = O-ring Silicon (Standard)

Output Fitting Option

Blank = Polypro construction

-E = Polyethylene shell and HDPE media support for gamma sterilization

-GP = Gamma stable polypropylene shell -G(pore Size)= Glass Fiber

PreFilter

70mm Diameter Capsule with Bleed

Valve

-NI = No vent or drain inlet fitting Silicon O-Rings for Bleed

Valve and Quick Coupling fittings

-NO = No vent or drain Outlet fitting

Example - PureFlo SKV Series Capsule, Nylone , 2.5" internal filter, 0.2 micron, with 1.5" Tri-Clamp fittings I/O, w/PP Construction, would be SKVN020STCTC

Note Quick Couplings are molded on. Compat ble with CPC (Colder), LinkTech and others. * - 2H or 3H with fil ing bell only

Page 49

Page 51: ZenPure - Q-Test

PureFlo All Nylon Filter Capsules

(SNL Series)

ZenPure Z

en

Pu

re

All Nylon Capsule

PureFlo® All Nylon filter capsules are highly retentive, naturally hydrophilic nylon membrane filters that have been specially designed for liquid applications. The ny-lon membrane in an all-nylon construction provides excellent chemical compatibility and superior flow per unit area as compared to other membrane capsules. No adhesives, binders, or surfactants are used in the manufacturing process. All capsules are rinsed with high-purity water to reduce extractables and downtime.

The naturally hydrophilic nylon membrane does not re-quire pre-wetting with IPA and flushing with DI water, thereby eliminating a potential source of contamination and hazardous waste.

All filter capsules are 100% integrity tested to ensure filter performance each and every time out of the pack-age. PureFlo nylon filter capsules are well-suited for critical applications where superior flow and particle re-moval efficiency at 0.05, 0.1, 0.2, 0.45, 0.65, 0.8, and 1.2 micron is required.

Specifications

Materials of Construction: Media: Naturally Hydrophilic Nylon Media Supports: None Cage, Core, End Caps: Nylon Sealing: Thermally bonded Fitting Connections: See ordering guide for the availability. (Custom adaptors available upon request) Nominal Dimensions: Lengths: 1.5in. (68mm), 2.5in. (98mm), 5in. (153mm), 7.5in. (251mm), and 10in. (281mm)

Diameter: 2.88 in. (73mm)

Effective Filtration Area: 1.5 in - 0.74 ft2 (690 cm2), 2.5 in - 1.4 ft2 (1300 cm2), 5.0 in - 2.64 ft2 (2450 cm2), 7.5 in - 4.0ft2 (3750 cm2), 10 in - 5.3 ft2 (4900 cm2) Operating Conditions: Maximum Operating Pressure: Liquid: 5.5 bar (80psi) at 77°F/25°C Liquid: 3.0 bar (43.5psi) at 203°F/95°C Gas: 4.1 bar (60psi) at 77°F/25°C Maximum Forward Differential Pressure: 4.2 bar (60psi) at 68°F/20°C 1.5 bar (21.75psi) at 203°F/95°C Maximum Reverse Differential Pressure: 2.1 bar (30 psi) at 68°F/20°C Minimum Burst Pressure: 8.3 bar (120psi) at 77°F/25°C Maximum Operating Temperature: : 203°F/95°C

Applications Solvents Water Hard Particle Beverages Cell Removal Pharmaceuticals Chemicals Biologics

Page 50

Page 52: ZenPure - Q-Test

ZenPure PureFlo All Nylon Filter Capsules

(SNL Series)

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

B13.1 Rev 2011.08

Specifications (cont.)

Autoclavable & Sanitizable: Capsules can be autoclaved 25 times at 257°F/125°C for 30 minutes or chemically sanitized in situ using common sani-tizing agents or hot water at 194°F/90°C for a limited time (dependent on time and temperature). Capsules must not be in situ steam-sterilized.

Regulatory Compliance: The filters are constructed with polypropylene resins and filtration media in compliance with 21CFR Part 177 of the US Code of Federal Regulations and USP Class VI Biological Test for Plastic.

PureFlo All Nylon Filter Capsule Ordering Guide

0

2

4

6

8

10

0

0.08

0.16

0.24

0.32

0.4

0.48

0.56

0.64

0 0.5 1 1.5 2

0 1 2 3 4 5 6 7

PureFlo 1.5" PES Capsule

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

1/4" Commpression fitting

0.050.1

0.2

0.45 0.651.0

0

2

4

6

8

10

0

0.08

0.16

0.24

0.32

0.4

0.48

0.56

0.64

0 0.5 1 1.5 2 2.5 3

0 2 4 6 8 10

PureFlo 2.5" Nylon Capsule

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

1/4" Commpression fitting

0.050.1

0.2

0.45

0.65

1.0

0

2

4

6

8

10

0

0.08

0.16

0.24

0.32

0.4

0.48

0.56

0.64

0 1 2 3 4 5

0 4 8 12 16

PureFlo 5" Nylon Capsule

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

1/4" Commpression fitting

0.05

0.10.2

0.45

0.651.0

PureFlo Capsule

Filters

Vent & Drain

Fitting

Filter

Media

Pore size

(Micron)Length Options

005= 0.05 H = 1.5" 1H = 1/8" Hose barbs 1H = 1/8" Hose barbsSN 010 = 0.10 S = 2 5" 1NF = 1/8" FNPT 1NF = 1/8" FNPT

020 = 0.20 L = 5" 1QF = 1/8" Female Quick Coupling w/ Metal latch 1QF = 1/8" Female Quick Coupling w/ Metal latch045 = 0.45 E = 7 5" 2H = 1/4" to 1/2" Hose barbs 2H = 1/4" to 1/2" Hose barbs

70mm Diameter C l

065 = 0.65 K = 10" 2HS = 1/4" to 3/8" Hose barbs 2HS = 1/4" to 3/8" Hose barbs080 = 0.80 2LF = Large Female Luer Lock fitting 2LF = Large Female Luer Lock fitting120 = 1.20 2N = 1/4" MNPT 2N = 1/4" MNPT

2NF = 1/4" FNPT 2NF = 1/4" FNPT2Q = 1/4" Male Quick Coupling for Metal latch 2Q = 1/4" Male Quick Coupling for Metal latch2QF = 1/4" Female Quick Coupling w/ Metal latch 2QF = 1/4" Female Quick Coupling w/ Metal latch2QFP = 1/4" Female Quick Coupling w/ Plastic latch 2QFP = 1/4" Female Quick Coupling w/ Plastic latch2QP = 1/4" Male Quick Coupling for Plastic latch 2QP = 1/4" Male Quick Coupling for Plastic latch3H = 3/8" Hose Barb 3H = 3/8" Hose Barb 3HE = 3/8" Hose Barb Elbow 3HE = 3/8" Hose Barb Elbow3NF = 3/8" FNPT 3NF = 3/8" FNPT O-Ring for Quick Coupling

4H = 1/2" Hose Barb 4H = 1/2" Hose Barb -OE = O-ring EPDM4N = 1/2" MNPT 4N = 1/2" MNPT -ON = O-ring Nitrile4QP = 1/2" Male Quick Coupling for Plastic latch 4QP = 1/2" Male Quick Coupling for Plastic latch -OV = O-ring VitonMT = 1/2" Tri clamps MT = 1/2" Tri clampsTC = 1-1/2" Tri clamp TC = 1-1/2" Tri clamp

Blank = O-ring Silicon (Standard)

Example - 0.2um Nylon with Nylon Construction, Luer Lock V/D, 1 5" internal filter, 1/4" MNPT I/O is SNLN020H2N2N

Quick Couplings are molded Female Quick Coupling with Plastic latch will be threaded on compatible with CPC (Colder) LinkTech and others.

Input Fitting Output Fitting

N = Nylon

-N = No vent or Drain fittings

-NI = No vent or drain inlet fitting

-NO = NO vent or drain Outlet fitting

L = Female Luer Lock Blank = Nylon construction

Media on All Nylon Construction P = M8 Threaded

Plug - Limited options-FB = Filling bell

-FC = Filling bell with Cap

-ETO = Ethylene oxide sterilization

Page 51

Page 53: ZenPure - Q-Test

PureFlo All Nylon Filter Capsules

(SNV Series)

ZenPure Z

en

Pu

re

All Nylon Capsule

PureFlo® SKN Series All Nylon filter capsules are highly retentive, naturally hydrophilic nylon membrane filters that have been specially designed for liquid applica-tions. The nylon membrane in an all-nylon construction provides excellent chemical compatibility and superior flow per unit area as compared to other membrane cap-sules. No adhesives, binders, or surfactants are used in the manufacturing process. All capsules are rinsed with high-purity water to reduce extractables and downtime.

The SKN capsules were designed with built-in bleed valves for simple and efficient evacuation of air and liq-uid from the upstream side. The naturally hydrophilic nylon membrane does not require pre-wetting with IPA and flushing with DI water, thereby eliminating a poten-tial source of contamination and hazardous waste.

All filter capsules are 100% integrity tested to ensure filter performance each and every time out of the pack-age. PureFlo nylon filter capsules are well-suited for critical applications where superior flow and particle re-moval efficiency at 0.05, 0.1, 0.2, 0.45, 0.65, 0.8, and 1.2 micron is required.

Specifications

Materials of Construction: Media: Naturally Hydrophilic Nylon Media Supports: None Cage, Core, End Caps: Nylon Sealing: Thermally bonded Fitting Connections: See ordering guide for the availability. (Custom adaptors available upon request) Nominal Dimensions: Length: 1.5in. (68mm), 2.5in. (98mm), 5in. (153mm), 7.5in. (251mm), and 10in. (281mm)

Diameter: 2.88 in. (73mm)

Effective Filtration Area: 1.5 in - 0.74 ft2 (690 cm2), 2.5 in - 1.4 ft2 (1300 cm2), 5.0 in - 2.64 ft2 (2450 cm2), 7.5 in - 4.0ft2 (3750 cm2), 10 in - 5.3 ft2 (4900 cm2) Operating Conditions: Maximum Operating Pressure: Liquid: 5.5 bar (80psi) at 77°F/25°C Gas: 4.1 bar (60psi) at 77°F/25°C Maximum Forward Differential Pressure: 4.2 bar (60psi) at 68°F/20°C Maximum Reverse Differential Pressure: 2.1 bar (30 psi) at 68°F/20°C Minimum Burst Pressure: 8.3 bar (120psi) at 77°F/25°C Maximum Operating Temperature: 203°F/95°C

Applications Solvents Water Hard Particle Beverages Cell Removal Pharmaceuticals Chemicals Biologics

Page 52

Page 54: ZenPure - Q-Test

ZenPure PureFlo All Nylon Filter Capsules

(SNV Series)

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

B13.2 Rev 2011.08

Specifications (cont.)

Autoclavable & Sanitizable: Capsules can be autoclaved 25 times at 257°F/125°C for 30 minutes or chemically sanitized in situ using common sani-tizing agents or hot water at 194°F/90°C for a limited time (dependent on time and temperature). Capsules must not be in situ steam-sterilized.

Regulatory Compliance: The filters are constructed with polypropylene resins and filtration media in compliance with 21CFR Part 177 of the US Code of Federal Regulations and USP Class VI Biological Test for Plastic.

PureFlo All Nylon Filter Capsule Ordering Guide

0

2

4

6

8

10

0

0.08

0.16

0.24

0.32

0.4

0.48

0.56

0.64

0 0.5 1 1.5 2

0 1 2 3 4 5 6 7

PureFlo 1.5" PES Capsule

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

1/4" Commpression fitting

0.050.1

0.2

0.45 0.651.0

0

2

4

6

8

10

0

0.08

0.16

0.24

0.32

0.4

0.48

0.56

0.64

0 0.5 1 1.5 2 2.5 3

0 2 4 6 8 10

PureFlo 2.5" Nylon Capsule

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

1/4" Commpression fitting

0.050.1

0.2

0.45

0.65

1.0

0

2

4

6

8

10

0

0.08

0.16

0.24

0.32

0.4

0.48

0.56

0.64

0 1 2 3 4 5

0 4 8 12 16

PureFlo 5" Nylon Capsule

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

1/4" Commpression fitting

0.05

0.10.2

0.45

0.651.0

PureFlo Capsule

Filters

Filter

Media

Pore size

(Micron)

Internal

Filter

Length

Option

005 = 0.05 H = 1 5" 1H = 1/8" Hose Barbs 1H = 1/8" Hose BarbsSNV 010 = 0.10 S = 2.5" 1NF = 1/8" FNPT 1NF = 1/8" FNPT

020 = 0.20 L = 5" 1QF = 1/8" Female Quick Coupling with Metal Latch 1QF = 1/8" Female Quick Coupling with Metal Latch -FB = Filling BellNylon Construction 045 = 0.45 E = 7.5" 2H = 1/4" Hose Barbs 2H = 1/4" Hose Barbs -FC = Filling Bell w/ Cap

065 = 0.65 K = 10" 2N = 1/4" MNPT 2N = 1/4" MNPT080 = 0.80 2NF = 1/4" FNPT 2NF = 1/4" FNPT120 = 1.20 2Q = 1/4" Male Quick Coupling for Metal Latch 2Q = 1/4" Male Quick Coupling for Metal Latch

2QF = 1/4" Female Quick Coupling w/ Metal Latch 2QF = 1/4" Female Quick Coupling w/ Metal Latch2QFP = 1/4" Female Quick Coupling w/ Plastic Latch 2QFP = 1/4" Female Quick Coupling w/ Plastic Latch2QP = 1/4" Male Quick Coupling for Plastic Latch 2QP = 1/4" Male Quick Coupling for Plastic Latch3H = 3/8" Hose Barb 3H = 3/8" Hose Barb 3NF = 3/8" FNPT 3NF = 3/8" FNPT4H = 1/2" Hose Barb 4H = 1/2" Hose Barb 4N = 1/2" MNPT 4N = 1/2" MNPT4QP = 1/2" Male Quick Coupling for Plastic latch 4QP = 1/2" Male Quick Coupling for Plastic latch -OE = O-ring EPDMMT = 1/2" Tri-clamps MT = 1/2" Tri-clamps -ON = O-ring NitrileTC = 1-1/2" Tri-clamp TC = 1-1/2" Tri-clamp -OV = O-ring Viton

Silicon o-rings for Bleed Valve and Quick Coupling fittings

Blank = O-ring Silicon (Standard)

Example - PureFlo SNV Series Capsule, Nylon , 2.5" internal filter, 0.2 micron, with 1.5" Tri-Clamp fittings I/O, would be SNVN020STCTC

Quick Coup ings are molded on. Female Quick Coupling with Plastic latch will be threaded on. Compatible with CPC (Colder) LinkTech and others.

N = Nylon

Input Fitting Output Fitting

O-Ring for Quick

Coupling

70mm Diameter Capsule with Bleed

Valve

-ETO = Ethylene oxide sterilization

-N= No vent or drain fittings

-NI = No vent or drain inlet fitting

-NO = No vent or drain Outlet fitting

Blank = Nylon construction

Page 53

Page 55: ZenPure - Q-Test

PureFlo Nylon Screen Filter Capsules

(Nylon Screen on PP Construction)

ZenPure Z

en

Pu

re

Screen Filtration

PureFlo® nylon screen capsule filters are designed for filtration and clarification applications in the pharmaceutical, biotechnology, food and beverage, medical, chemical, and water worldwide. This family of products is particularly suitable for the fluids with large sizes particles. The nylon screen removes particles by a sieving. Hard particles can be easily removed by the use of these units.

The nylon screen in an all-polypropylene construc-tion provides excellent chemical compatibility. It can also be constructed in Nylon, Polyethylene and Gamma stabilized PP shells. PureFlo nylon screen filter capsules are well-suited for applications. No adhesives, binders, or surfactants are used in the manufacturing process. All capsules are rinsed with high-purity water to reduce extractables and downtime in a clean room environment to ensure filter performance each and every time out of the package.

Specifications Materials of Construction: Media: Nylon Screen Media Supports: Nylon Cage, Core, End Caps: Polypropylene, Gamma Stabilized PP, Nylon Sealing: Thermally bonded Fitting Connections: See ordering guide for the availability. (Custom adaptors available upon request) Effective Filtration Area: Lengths: 1.5” 0.65ft2 (500cm2), 2.5” 1.3ft2 (1000cm2), 5” 2.1ft2 (2000cm2), 7.5” 3.2ft2 (3000cm2) and 10” 4.3ft2 (4000cm2)

Diameter: 2.75 in. (70mm)

Available Ratings: 10um, 20um, 40um, 60um, 100um, and 200um Operating Conditions: Maximum Operating Pressure: Liquid: 5.5 bar (80psi) at 77°F/25°C Gas: 4.1 bar (60psi) at 77°F/25°C Maximum Forward Differential Pressure: 4.21 bar (60psi) at 68°F/20°C Maximum Reverse Differential Pressure: 2.1 bar (30 psi) at 68°F/20°C Minimum Burst Pressure: 8.3 bar (120psi) at 77°F/25°C Maximum Operating Temperature: 176°F/80°C Regulatory Compliance: The filters are constructed with polypropylene resins and filtration media in compliance with 21CFR Part 177 of the US Code of Federal Regulations and USP Class VI Biological Test for Plastic.

Applications Clarification Water Hard Particle Beverages Cell Removal Pharmaceuticals Chemicals Biologics

Page 54

Page 56: ZenPure - Q-Test

ZenPure PureFlo Nylon Screen Filter Capsules

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

B13.3 Rev 2011.08

Specifications (cont.)

Autoclavable & Sanitizable: Capsules can be autoclaved 25 times at 257°F/125°C for 30 minutes or chemically sanitized in situ using common sanitizing agents or hot water at 194°F/90°C for a limited time (dependent on time and tempera-ture). Capsules must not be in situ steam-sterilized.

PureFlo Nylon Screen Filter Capsule Ordering Guide

PureFlo

Capsule

Filters

Vent & Drain

FittingFilter Media

Pore size

(Micron)Length

100 = 10 H = 1.5" 1H = 1/8" Hose barbs 1H = 1/8" Hose barbsSK 200 = 20 S = 2.5" 1NF = 1/8" FNPT 1NF = 1/8" FNPT

400 = 40 L = 5" 1Q = 1/8" Male Quick Coupling for Metal latch 1Q = 1/8" Male Quick Coupling for Metal latch -NY = Nylon Construction -OE = O-ring EPDM600 = 60 E= 7.5" 1QF = 1/8" Female Quick Coupling w/Metal latch 1QF = 1/8" Female Quick Coupling w/Metal latch -FB = Filling bell -ON = O-ring Nitrile10X = 100 K = 10" 2C = 1/4" Compression 2C = 1/4" Compression -FC = Filling bell with Cap -OV = O-ring Viton20X = 200 2H = 1/4" to 1/2" Hose barbs 2H = 1/4" to 1/2" Hose barbs

2HS = 1/4" to 3/8" Hose barbs 2HS = 1/4" to 3/8" Hose barbs2LF = Large Female Luer Lock fitting 2LF = Large Female Luer Lock fitting2N = 1/4" MNPT 2N = 1/4" MNPT2NF = 1/4" FNPT 2NF = 1/4" FNPT2Q = 1/4" Male Quick Coupling for Metal latch 2Q = 1/4" Male Quick Coupling for Metal latch2QF = 1/4" Female Quick Coupling w/Metal latch 2QF = 1/4" Female Quick Coupling w/Metal latch2QFP = 1/4" Female Quick Coupling w/Plastic latch 2QFP = 1/4" Female Quick Coupling w/Plastic latch2QP = 1/4" Male Quick Coupling for Plastic latch 2QP = 1/4" Male Quick Coupling for Plastic latch3C = 3/8" Compression 3C = 3/8" Compression3H = 3/8" Hose Barb 3H = 3/8" Hose Barb 3HE = 3/8" Hose Barb Elbow 3HE = 3/8" Hose Barb Elbow3NF = 3/8" FNPT 3NF = 3/8" FNPT4C = 1/2" Compression 4C = 1/2" Compression4H = 1/2" Hose Barb 4H = 1/2" Hose Barb 4N = 1/2" MNPT 4N = 1/2" MNPT4QP = 1/2" Male Quick Coupling for Plastic latch 4QP = 1/2" Male Quick Coupling for Plastic latchMT = 1/2" Tri clamps MT = 1/2" Tri clampsTC = 1-1/2" Tri clamp TC = 1-1/2" Tri clamp

-G(pore Size)= Glass Fiber PreFilter

-P(pore Size)= PolyPro Media PreFilter

-S(pore Size) = PES PreFilter

Quick Couplings are molded, Female Quick Coup ing w th Plastic latch will be threaded on, compatible with CPC (Colder), LinkTech and others.

Example - SK Series Capsule, Luer Lock V/D, 2.5" Internal filter, 20 micron Nylon Screen Capsule, Standard Grade, with 1.5" Tri-Clamp fittings would be SKLNS200STCTC

70mm Diameter Capsule N = No vent or

drain fittings-ETO = Ethylene oxide sterilization

-NI = No vent or drain inlet fitting

L = Female Luer Lock

-GP = Gamma stable polypropylene shell

O-Ring for Quick

CouplingNS = Nylon

ScreenP = M8 Threaded Plug - Limited options

Blank = O-ring Silicon (Standard)

PreFilters

Input Fitting Output Fitting Options

-NO = NO vent or drain Outlet fitting

-E = Polyethylene shell and HDPE media support for gamma sterilization

60um Nylon Screen

Page 55

Page 57: ZenPure - Q-Test

PureFlo® Polyethylene Filter Capsules

ZenPure Z

en

Pu

re

PureFlo® Polyethylene filter capsules are highly retentive

hydrophobic membrane filters that have been specially

designed for critical applications. The PE membrane in an

all-polypropylene construction provides excellent chemical

compatibility and superior flow per unit area as compared to

other membrane capsules. No adhesives, binders, or surfac-

tants are used in the manufacturing process and all cartridges

are rinsed with high-purity water to reduce extractables and

downtime.

The hydrophobic PE membrane is gamma stable and ideally

suited for sterile applications. In addition, the hydrophobic

membrane provides superior flow and pressure drop charac-

teristics per surface area for gas filtration and tank venting

applications. All filter capsules are 100% integrity tested to

ensure filter performance each and every time out of the

package. PureFlo PE filter capsules are well-suited for critical

applications where superior flow and particle removal

efficiency at 0.2 to 2.5 micron is required.

Applications

Sterile gasses and liquids Ink Jets

Bases Beverages

Solvents Pharmaceuticals

Fine Chemicals Biologics

Plating Solutions Dyes

Process Water Lacquers

Materials of Construction Membrane: Hydrophobic Polyethylene

Membrane Supports: Polyethylene

Cage, Core, End Caps, Capsule: Polyethylene

Fitting Connections: MNPT, FNPT, Quick Couplings, Compres-

sion, Hose Barb, Sanitary Flange

Dimensions (Nominal) Length: 1.5 in (68 mm) Length: 2.5 in (98 mm)

Length: 5.0 in (153 mm) Length: 7.5 in (251mm)

Length: 10 in (281mm)

Diameter: 2.88 in (73 mm)

Effective Filtration Area 1.5 in - 0.65 ft2 (500 cm2) 2.5 in - 1.3 ft2 (1000 cm2)

5.0 in - 2.7 ft2 (1900 cm2) 7.5 in - 4.3 ft2 (2900 cm2)

10 in - 5.2 ft2 (3800 cm2)

Operating Conditions Maximum Operating Pressure:

Liquid: 5.5 bar (80psi) at 77°F/25°C

Gas: 4.1 bar (60psi) at 77°F/25°C

Minimum Burst Pressure: 8.3 bar (120psi) at 77°F/25°C

Maximum Forward Differential Pressure:

5 bar (72psi) at 68°F/20°C

Maximum Reverse Differential Pressure:

3.0 bar (44psi) at 68°F/20°C

Maximum Operating Temperature: 140°F/60°C

Regulatory Compliance Manufactured from materials that conform to the re-

quirements of 21CFR Part 177 of the U.S. Code of Fed-

eral Regs and USP Class VI Biological Test for Plastics

Features Benefits

■ Naturally Hydrophobic PE Membrane ■ High flow rates with low pressure drop per surface area as

compared to other filter materials

■ Superior filter lifetime and process throughputs

■ Wide Chemical & Thermal Compatibility ■ Provides excellent compatibility with a wide-range of

chemicals such as acids, bases, and solvents

■ No media migration into the process fluid

■ Low Filter Extractables ■ No adhesives, binders, or surfactants are used during the manufacturing process resulting in superior downstream

cleanliness

■ All cartridges are rinsed with high-purity water to reduce

extractables and downtime

■ Quality Manufacturing ■ Consistent and reproducible particulate removal

Page 56

Page 58: ZenPure - Q-Test

ZenPure PureFlo® Polyethylene Filter Capsules

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

B13.5 Rev 2011.08

PureFlo Polyethylene Filter Cartridge Ordering Guide

1H = 1/8" Hose barbs Luer Lock1NF = 1/8" FNPT Luer Lock2C = 1/4" Compress on 1/4" Comp2H = 1/4" to 1/2" Hose barbs Luer Lock2HS = 1/4" to 3/8" Hose barbs Luer Lock2L = Large Female Luer Lock f tting Luer Lock2N = 1/4" MNPT Luer Lock2NF = 1/4" FNPT Luer Lock2Q = 1/4" Male Quick Coupling Luer Lock2QF = 1/4" Female Qu ck Coupling Luer Lock2QFP = 1/4" Female Qu ck Coupling with Plast c latch Luer Lock2QP = 1/4" Male Quick Coupling for Plast c latch Luer Lock3C = 3/8" Compress on 1/4" Comp3H = 3/8" Hose Barb (future) Luer Lock3HE = 3/8" Hose Barb Elbow Luer Lock3NF = 3/8" FNPT Luer Lock4C = 1/2" Commpression 1/4" Comp4H = 1/2" Hose Barb (future) Luer Lock4N = 1/2" MNPT Luer Lock4QP = 1/2" Male Quick Coupling for Plast c latch Luer LockMT = 0.5" Tri clamps Luer LockTC = 1-1/2" Tri clamp Luer Lock

Inlet/Outlet Fittings

Vent and

Drain

fittings

Option: Plugged and Cut off Vent and/or Drains

PureFlo

Capsule

Filters

Vent & Drain

FittingFilter Media

Pore size

(Micron)Length

020 = 0.20 H = 1.5" 1H = 1/8" Hose barbs 1H = 1/8" Hose barbsSK 100 = 1.0 S = 2.5" 1NF = 1/8" FNPT 1NF = 1/8" FNPT

150 = 1.5 L = 5" 1Q = 1/8" Male Quick Coupling for Metal latch 1Q = 1/8" Male Quick Coupling for Metal latch -NY = Nylon Construction -OE = O-ring EPDM250 = 2.5 E= 7.5" 1QF = 1/8" Female Quick Coupling w/Metal latch 1QF = 1/8" Female Quick Coupling w/Metal latch -FB = Filling bell -ON = O-ring Nitrile

K = 10" 2H = 1/4" to 1/2" Hose barbs 2H = 1/4" to 1/2" Hose barbs -FC = Filling bell with Cap -OV = O-ring Viton2HS = 1/4" to 3/8" Hose barbs 2HS = 1/4" to 3/8" Hose barbs2LF = Large Female Luer Lock fitting 2LF = Large Female Luer Lock fitting2N = 1/4" MNPT 2N = 1/4" MNPT2NF = 1/4" FNPT 2NF = 1/4" FNPT2Q = 1/4" Male Quick Coupling for Metal latch 2Q = 1/4" Male Quick Coupling for Metal latch2QF = 1/4" Female Quick Coupling w/Metal latch 2QF = 1/4" Female Quick Coupling w/Metal latch2QFP = 1/4" Female Quick Coupling w/Plastic latch 2QFP = 1/4" Female Quick Coupling w/Plastic latch2QP = 1/4" Male Quick Coupling for Plastic latch 2QP = 1/4" Male Quick Coupling for Plastic latch3H = 3/8" Hose Barb 3H = 3/8" Hose Barb 3HE = 3/8" Hose Barb Elbow 3HE = 3/8" Hose Barb Elbow3NF = 3/8" FNPT 3NF = 3/8" FNPT4H = 1/2" Hose Barb 4H = 1/2" Hose Barb 4N = 1/2" MNPT 4N = 1/2" MNPT4QP = 1/2" Male Quick Coupling for Plastic latch 4QP = 1/2" Male Quick Coupling for Plastic latchMT = 1/2" Tri clamps MT = 1/2" Tri clampsTC = 1-1/2" Tri clamp TC = 1-1/2" Tri clamp

O-Ring for Quick

Coupling

Blank = O-ring Silicon (Standard)

PreFilters

-G(pore Size)= Glass Fiber PreFilter

-P(pore Size)= PolyPro Media PreFilter

-S(pore Size) = PES PreFilter

-E = Polyethylene shell and HDPE media support for gamma sterilization

Example - SK Series Capsule, Luer Lock V/D, 2.5" Internal filter, 1.5 micron Polyethylene Capsule, Standard Grade, with 1.5" Tri-Clamp fittings would be SKLPE150STCTC

Quick Couplings are molded Female Quick Coupling w th Plastic latch wi l be threaded on compatible with CPC (Colder) LinkTech and others.

N = No vent or drain fittings

-ETO = Ethylene oxide sterilization

-NI = No vent or drain inlet fitting

-NO = NO vent or drain Outlet fitting

Input Fitting Output Fitting Options

L = Female Luer Lock

-GP = Gamma stable polypropylene shell

E = PolyethyleneP = M8 Threaded

Plug - Limited options

70mm Diameter Capsule

Page 57

Page 59: ZenPure - Q-Test

PureFlo® Glass Microfiber Filter Capsules

ZenPure Z

en

Pu

re

PureFlo® Borosilicate Microfiber filter cartridges are highly

retentive filters that have a pleated design to maximize surface

area. The borosilicate microfiber media in an all-

polypropylene construction provides excellent chemical com-

patibility and superior flow per unit area. No adhesives or

surfactants are used in the manufacturing process. The boro-

silicate microfiber is “non-fiber releasing.”

The borosilicate microfiber is ideally-suited for aggressive

microbial retention. In addition, the media provides superior

flow and pressure drop characteristics per unit area. PureFlo

Microfiber filter cartridges are well-suited for critical applica-

tions where superior flow and particle retention for deform-

able and non-deformable particle removal is required.

Applications

Prefiltration Biologics

Serums Bio-burden reduction

Pharmaceuticals Retention of

deformable particles

Wine Clarification Inks

Food & Beverage Cosmetics

Features Benefits

■ Borosilicate Microfiber Media

(Absolute Rated)

■ High dirt-loading capacity

■ Natural positive charge

■ Superior process throughputs

■ Wide Chemical & Thermal Compatibility ■ Provides excellent compatibility

■ No media migration

■ Quality Construction ■ No adhesives or surfactants

■ Thermally welded construction

Materials of Construction Media: Non-Woven Borosilicate Microfiber

Pleate Supports: Polypropylene

Cage, Core, End Caps: Polypropylene

Fitting Connections: NPT, Couplings

Compression, Hose Barb, Sanitary Flange

Dimensions (Nominal) Length: 1.5 in (68 mm) Length: 2.5 in (98 mm)

Length: 5.0 in (153 mm) Length: 7.5 in (251 mm)

Length: 10 in (281mm)

Diameter: 2.88 in (73 mm)

Effective Filtration Area 1.5 in - 0.48 ft2 (450 cm2) 2.5 in - 1.0 ft2 (950 cm2)

5.0 in - 1.8 ft2 (1700 cm2) 7.5 in - 4.3 ft2 (3980 cm2)

10 in - 3.66 ft2 (3400 cm2)

Operating Conditions Maximum Operating Pressure:

Liquid: 5.5 bar (80psi) at 77°F/25°C

Gas: 4.1 bar (60psi) at 77°F/25°C

Minimum Burst Pressure:

8.3 bar (120psi) at 77°F/25°C

Maximum Forward Differential Pressure:

4.21 bar (60psi) at 68°F/20°C

Maximum Reverse Differential Pressure:

2.1 bar (30psi) at 68°F/20°C

Maximum Operating Temperature:

PP & Gamma PP: 176°F/80°C HDPE: 140°F/60°C

Regulatory Compliance

Manufactured from materials that conform to the re-

quirements of USP Class VI Biological Test for Plastics.

Autoclave Cycles

25 times @ 257°F/125°C for 30 minutes

Capsules must not be in situ steam-sterilized

Page 58

Page 60: ZenPure - Q-Test

ZenPure PureFlo® Glass Microfiber Filter Capsules

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

B13.8 Rev 2011.07

PureFlo Glass Fiber Filter Cartridge Ordering Guide

PureFlo

Capsule

Filters

Vent & Drain

FittingFilter Media

Pore size

(Micron)Length

004 = 0.45 H = 1.5" 1H = 1/8" Hose barbs 1H = 1/8" Hose barbsSK 005 = 0.5 S = 2.5" 1NF = 1/8" FNPT 1NF = 1/8" FNPT

010 = 1.0 L = 5" 1Q = 1/8" Male Quick Coupling for Metal latch 1Q = 1/8" Male Quick Coupling for Metal latch -NY = Nylon Construction -OE = O-ring EPDM030 = 3.0 E= 7.5" 1QF = 1/8" Female Quick Coupling w/Metal latch 1QF = 1/8" Female Quick Coupling w/Metal latch -FB = Filling bell -ON = O-ring Nitrile050 = 5.0 K = 10" 2C= 1/4" Compression 2C= 1/4" Compression -FC = Filling bell w/Cap -OV = O-ring Viton100 = 10.0 2H = 1/4" to 1/2" Hose barbs 2H = 1/4" to 1/2" Hose barbs200 = 20.0 2HS = 1/4" to 3/8" Hose barbs 2HS = 1/4" to 3/8" Hose barbs300 = 30.0 2LF = Large Female Luer Lock fitting 2LF = Large Female Luer Lock fitting

2N = 1/4" MNPT 2N = 1/4" MNPT2NF = 1/4" FNPT 2NF = 1/4" FNPT2Q = 1/4" Male Quick Coupling for Metal latch 2Q = 1/4" Male Quick Coupling for Metal latch2QF = 1/4" Female Quick Coupling w/Metal latch 2QF = 1/4" Female Quick Coupling w/Metal latch2QFP = 1/4" Female Quick Coupling w/Plastic latch 2QFP = 1/4" Female Quick Coupling w/Plastic latch2QP = 1/4" Male Quick Coupling for Plastic latch 2QP = 1/4" Male Quick Coupling for Plastic latch3C = 3/8" Compression 3C = 3/8" Compression3H = 3/8" Hose Barb 3H = 3/8" Hose Barb 3HE = 3/8" Hose Barb Elbow 3HE = 3/8" Hose Barb Elbow3NF = 3/8" FNPT 3NF = 3/8" FNPT4C = 1/2" Compression 4C = 1/2" Compression 4H = 1/2" Hose Barb 4H = 1/2" Hose Barb 4N = 1/2" MNPT 4N = 1/2" MNPT4QP = 1/2" Male Quick Coupling for Plastic latch 4QP = 1/2" Male Quick Coupling for Plastic latchMT = 1/2" Tri clamps MT = 1/2" Tri clampsTC = 1-1/2" Tri clamp TC = 1-1/2" Tri clamp

O-Ring for Quick

Coupling

Blank = O-ring Silicon (Standard)

Input Fitting Output Fitting Options

L = Female Luer Lock

-GP = Gamma stable polypropylene shell

G = Glass FiberP = M8 Threaded

Plug - Limited options

70mm Diameter Capsule N = No vent or

drain fittings-ETO = Ethylene oxide sterilization

-NI = No vent or drain inlet fitting

-NO = NO vent or drain Outlet fitting

-E = Polyethylene shell and HDPE media support for gamma sterilization

PreFilters

-G(pore Size)= Glass Fiber PreFilter

-P(pore Size)= PolyPro Media PreFilter

-S(pore Size) = PES PreFilter

Example - SK Series Capsule, Luer Lock V/D, 2.5" Internal filter, 0.3 micron Glass Fiber Capsule, Standard Grade, with 1.5" Tri-Clamp fittings would be SKLG030STCTC

Quick Couplings are molded, Female Quick Coupling w th Plastic latch will be threaded on, compatible w th CPC (Colder), LinkTech and others.

1H = 1/8" Hose barbs Luer Lock1NF = 1/8" FNPT Luer Lock2C = 1/4" Compression 1/4" Comp2H = 1/4" to 1/2" Hose barbs Luer Lock2HS = 1/4" to 3/8" Hose barbs Luer Lock2L = Large Female Luer Lock fitting Luer Lock2N = 1/4" MNPT Luer Lock2NF = 1/4" FNPT Luer Lock2Q = 1/4" Male Qu ck Coupling Luer Lock2QF = 1/4" Female Quick Coupling Luer Lock2QFP = 1/4" Female Qu ck Coupling w th Plastic latch Luer Lock2QP = 1/4" Male Quick Coupling for Plast c latch Luer Lock3C = 3/8" Compression 1/4" Comp3H = 3/8" Hose Barb (future) Luer Lock3HE = 3/8" Hose Barb Elbow Luer Lock3NF = 3/8" FNPT Luer Lock4C = 1/2" Commpression 1/4" Comp4H = 1/2" Hose Barb (future) Luer Lock4N = 1/2" MNPT Luer Lock4QP = 1/2" Male Quick Coupling for Plast c latch Luer LockMT = 0.5" Tri clamps Luer LockTC = 1-1/2" Tri clamp Luer Lock

Inlet/Outlet Fittings

Vent and

Drain

fittings

Option: Plugged and Cut off Vent and/or Drains

Page 59

Page 61: ZenPure - Q-Test

PureFlo® Polypropylene Membrane Filter Capsules

ZenPure Z

en

Pu

re

PureFlo® polypropylene membrane filter capsules are highly

retentive and naturally hydrophobic filters. Polypropylene

membrane is a reliable choice for the purification of

aggressive chemicals, compressed gases, and vent applica-

tions. The all-polypropylene construction is an excellent

economic alternative to the more expensive fluoropolymer

based medias.

No adhesives, binders, or surfactants are used in the

manufacturing process. The membrane does not allow for

migration of particle into the process fluid, thereby reducing

the potential for contamination and downtime. Furthermore,

the all-polypropylene construction provides excellent thermal

and chemical compatibility with low and high pH chemicals.

PureFlo polypropylene membrane filter capsules are absolute

rated to ensure consistent filter performance each and every

time. All filter capsules are 100% integrity tested to ensure

filter performance.

Applications

Acids Ink Jets

Bases Tank vents

Solvents Lacquers

Fine Chemicals Dyes

Features Benefits

■ Absolute Rated Polypropylene Membrane ■ Consistent and reproducible particulate removal

■ High flow rates and low pressure drops

■ Superior filter lifetime and process throughputs

■ Consistent and reproducible particulate removal

■ 100% Polypropylene Disposable Capsule ■ Excellent thermal and chemical compatibility

■ Rapid installation and reduced downtime

■ Reduced chemical handling and hazardous waste disposal

■ Low Filter Extractables ■ No adhesives, binders, or surfactants are used during manu-

facturing resulting in superior downstream cleanliness

Materials of Construction Membrane: Polypropylene (hydrophobic)

Membrane Supports: Polypropylene

Cage, Core, End Caps: Polypropylene

Fitting Connections: MNPT, FNPT, Flare Compression,

Hose Barb, Sanitary Flange

Dimensions (Nominal) Length: 1.5 in (68 mm) Length: 2.5 in (98 mm)

Length: 5.0 in (153 mm) Length: 7.5 in (251 mm)

Length: 10 in (281mm)

Diameter: 2.88 in (73 mm)

Effective Filtration Area 1.5 in: 0.7 ft2 (650 cm2) 2.5 in: 1.4 ft2 (1300 cm2)

5.0 in: 2.7 ft2 (2500 cm2) 7.5 in: 4.3 ft2 (3980 cm2

10 in: 5.4 ft2 (5000 cm2)

Operating Conditions Maximum Operating Pressure:

Liquid: 5.5 bar (80psi) at 77°F/25°C

Gas: 4.1 bar (60psi) at 77°F/25°C

Minimum Burst Pressure:

8.3 bar (120psi) at 77°F/25°C

Maximum Forward Differential Pressure:

4.21 bar (60psi) at 68°F/20°C

Maximum Reverse Differential Pressure:

2.1 bar (30psi) at 68°F/20°C

Maximum Operating Temperature:

PP & Gamma PP: 176°F/80°C HDPE: 140°F/60°C

Page 60

Page 62: ZenPure - Q-Test

ZenPure PureFlo® Polypropylene Membrane Filter Capsules

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

b14 Rev 2011.08

0

2

4

6

8

10

0

0.08

0.16

0.24

0.32

0.4

0.48

0.56

0.64

0 0.5 1 1.5 2 2.5 3

0 2 4 6 8 10

PureFlo 1.5" PolyPro Membrane Capsule

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

1.5" Tri Clamp fitting

0.1

0.2

0

2

4

6

8

10

0

0.08

0.16

0.24

0.32

0.4

0.48

0.56

0.64

0 0.5 1 1.5 2 2.5 3

0 2 4 6 8 10

PureFlo 2.5" PolyPro Membrane Capsule

GPM

BarPSID

LPM

Dff

ere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

1.5" Tri Clamp fitting

0.1

0.2

0

2

4

6

8

10

0

0.08

0.16

0.24

0.32

0.4

0.48

0.56

0.64

0 0.5 1 1.5 2 2.5 3

0 2 4 6 8 10

PureFlo 5" PolyPro Membrane Capsule

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

1.5" Tri Clamp fitting

0.1

0.2

PureFlo Ordering Guide

Regulatory Compliance Manufactured from materials that conform to the requirements

of 21CFR Part 177 of the U.S. Code of Federal Regulations

and USP Class VI Biological Test for Plastics.

Autoclavable & Sanitizable Capsules can be autoclaved 25 times at 257°F/125°C for 30

minutes or chemically sanitized in situ using common sanitizing

agents or hot water at 194°F/90°C for a limited time (dependent

on time and temperature). Capsules must not be in situ steam-

sterilized.

Note - Graphs based on Sanitary fittings.

1H = 1/8" Hose barbs Luer Lock1NF = 1/8" FNPT Luer Lock2C = 1/4" Compression 1/4" Comp2H = 1/4" to 1/2" Hose barbs Luer Lock2HS = 1/4" to 3/8" Hose barbs Luer Lock2L = Large Female Luer Lock fitting Luer Lock2N = 1/4" MNPT Luer Lock2NF = 1/4" FNPT Luer Lock2Q = 1/4" Male Quick Coupling Luer Lock2QF = 1/4" Female Quick Coupling Luer Lock2QFP = 1/4" Female Quick Coupling with Plastic latch Luer Lock2QP = 1/4" Male Quick Coupling for Plastic latch Luer Lock3C = 3/8" Compression 1/4" Comp3H = 3/8" Hose Barb (future) Luer Lock3HE = 3/8" Hose Barb Elbow Luer Lock3NF = 3/8" FNPT Luer Lock4C = 1/2" Commpression 1/4" Comp4H = 1/2" Hose Barb (future) Luer Lock4N = 1/2" MNPT Luer Lock4QP = 1/2" Male Quick Coupling for Plastic latch Luer LockMT = 0 5" Tri clamps Luer LockTC = 1-1/2" Tri clamp Luer Lock

Inlet/Outlet Fittings

Vent and

Drain

fittings

Option: Plugged and Cut off Vent and/or Drains

PureFlo

Capsule

Filters

Vent & Drain

FittingFilter Media

Pore size

(Micron)Length

010 = 0.1 H = 1.5" 1H = 1/8" Hose barbs 1H = 1/8" Hose barbsSK 020 = 0.2 S = 2.5" 1NF = 1/8" FNPT 1NF = 1/8" FNPT

L = 5" 1Q = 1/8" Male Quick Coupling for Metal latch 1Q = 1/8" Male Quick Coupling for Metal latch -NY = Nylon Construction -OE = O-ring EPDME= 7.5" 1QF = 1/8" Female Quick Coupling w/Metal latch 1QF = 1/8" Female Quick Coupling w/Metal latch -FB = Filling bell -ON = O-ring NitrileK = 10" 2H = 1/4" to 1/2" Hose barbs 2H = 1/4" to 1/2" Hose barbs -FC = Filling bell w/Cap -OV = O-ring Viton

2HS = 1/4" to 3/8" Hose barbs 2HS = 1/4" to 3/8" Hose barbs2LF = Large Female Luer Lock fitting 2LF = Large Female Luer Lock fitting2N = 1/4" MNPT 2N = 1/4" MNPT2NF = 1/4" FNPT 2NF = 1/4" FNPT2Q = 1/4" Male Quick Coupling for Metal latch 2Q = 1/4" Male Quick Coupling for Metal latch2QF = 1/4" Female Quick Coupling w/Metal latch 2QF = 1/4" Female Quick Coupling w/Metal latch2QFP = 1/4" Female Quick Coupling w/Plastic latch 2QFP = 1/4" Female Quick Coupling w/Plastic latch2QP = 1/4" Male Quick Coupling for Plastic latch 2QP = 1/4" Male Quick Coupling for Plastic latch3H = 3/8" Hose Barb 3H = 3/8" Hose Barb 3HE = 3/8" Hose Barb Elbow 3HE = 3/8" Hose Barb Elbow3NF = 3/8" FNPT 3NF = 3/8" FNPT4H = 1/2" Hose Barb 4H = 1/2" Hose Barb 4N = 1/2" MNPT 4N = 1/2" MNPT4QP = 1/2" Male Quick Coupling for Plastic latch 4QP = 1/2" Male Quick Coupling for Plastic latchMT = 1/2" Tri clamps MT = 1/2" Tri clampsTC = 1-1/2" Tri clamp TC = 1-1/2" Tri clamp

O-Ring for Quick

Coupling

Blank = O-ring Silicon (Standard)

PreFilters

-G(pore Size)= Glass Fiber PreFilter

-P(pore Size)= PolyPro Media PreFilter

-E = Polyethylene shell and HDPE media support for gamma sterilization

Example - SK Series Capsule, Luer Lock V/D, 2.5" Internal filter, 0.2 micron PolyPro Membrane Capsule, Standard Grade, with 1.5" Tri-Clamp fittings would be SKLM020STCTC

Quick Couplings are molded Female Quick Coupling w th Plastic latch will be threaded on compatible with CPC (Colder) LinkTech and others.

-S(pore Size) = PES PreFilter

N = No vent or drain fittings

-ETO = Ethylene oxide sterilization

-NI = No vent or drain inlet fitting

-NO = NO vent or drain Outlet fitting

Input Fitting Output Fitting Options

L = Female Luer Lock

-GP = Gamma stable polypropylene shell

M = PolyPro MembraneP = M8 Threaded

Plug - Limited options

70mm Diameter Capsule

Page 61

Page 63: ZenPure - Q-Test

PureFlo® Polypropylene Filter Capsules

ZenPure Z

en

Pu

re

PureFlo® Polypropylene filter capsules are highly retentive,

graded porosity, pleated polypropylene media filters that have

been specially designed for clarification and pre-filtration

applications.

The graded porosity design removes particles in sequence by

size – larger particles by the more open outer layers and

smaller particles by the tighter inner layers. The outer layers

act as a pre-filter while the inner layers provide the absolute

rating at the specified pore size. This efficiently spreads the

contaminants throughout the media matrix resulting in

superior contaminant holding capacity, lifetime, and pressure

drop as compared to other media cartridges.

No adhesives, binders, or surfactants are used in the

manufacturing process The non-woven media does not allow

for migration into the process fluid, thereby reducing the po-

tential for extractables and downtime. Furthermore, the all-

polypropylene construction provides excellent thermal and

chemical compatibility with low and high pH chemicals.

PureFlo Polypropylene filter capsules are absolute rated to

ensure consistent filter performance each and every time out

of the package. Available in a wide-variety of micron sizes.

Applications

Acids Ink Jets

Bases Beverages

Solvents Pharmaceuticals

Fine Chemicals Biologics

Plating Solutions Dyes

Process Water Lacquers

Features Benefits

■ Absolute Rated Pleated Polypropylene

Media (Graded Porosity Design)

■ Media matrix removes particles in sequence by size – larger

particles by the more open outer layers and smaller particles

by the tighter inner layers

■ High flow rates and low pressure drops

■ Superior filter lifetime and process throughputs

■ Consistent and reproducible particulate removal

■ 100% Polypropylene Disposable Capsule ■ Excellent thermal and chemical compatibility

■ No media migration

■ Rapid installation and reduced downtime

■ Reduced chemical handling and hazardous waste disposal

■ Low Filter Extractables ■ No adhesives, binders, or surfactants are used during manu-

facturing, resulting in superior downstream cleanliness

■ Capsules are rinsed with high-purity water

Materials of Construction Media: Non-Woven Polypropylene

Meda Supports: Polypropylene

Cage, Core, End Caps: Polypropylene

Fitting Connections: MNPT, FNPT,

Compression, Hose Barb, Sanitary Flange

Dimensions (Nominal) Length: 1.5 in (68 mm) Length: 2.5 in (98 mm)

Length: 5.0 in (153 mm) Length: 7.5 in (251 mm)

Length: 10 in (281mm)

Diameter: 2.88 in (73 mm)

Effective Filtration Area 1.5 in - 0.65 ft2 (600 cm2) 2.5 in - 1.3 ft2 (1200 cm2)

5.0 in - 2.7 ft2 (2400 cm2) 7.5 in - 4.3 ft2 (3980 cm2)

10 in - 5.2 ft2 (4800 cm2)

Operating Conditions Maximum Operating Pressure:

Liquid: 5.5 bar (80psi) at 77°F/25°C

Gas: 4.1 bar (60psi) at 77°F/25°C

Minimum Burst Pressure:

8.3 bar (120psi) at 77°F/25°C

Maximum Forward Differential Pressure:

4.21 bar (72psi) at 68°F/20°C

Maximum Reverse Differential Pressure:

2.1 bar (30psi) at 68°F/20°C

Maximum Operating Temperature:

176°F/80°C

Page 62

Page 64: ZenPure - Q-Test

ZenPure PureFlo® Polypropylene Filter Capsules

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

B15 Rev. 2011.07

0

1

2

3

4

5

6

7

8

0

0.1

0.2

0.3

0.4

0.5

0 0.5 1 1.5 2 2.5 3

0 2 4 6 8 10

PureFlo 1.5" PolyPro Capsule

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

1.5" Tri Clamp fitting

0.3

0.6

1.0

3.0

5.0

30

10

50,70

0

1

2

3

4

5

0

0.04

0.08

0.12

0.16

0.2

0.24

0.28

0.32

0 0.5 1 1.5 2 2.5 3

0 2 4 6 8 10

PureFlo 2.5" PolyPro Capsule

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

1.5" Tri Clamp fitting

0.3

0.6

1.0

3.05.0

30

10

50,70

0

0.5

1

1.5

2

2.5

3

0

0.05

0.1

0.15

0.2

0 0.5 1 1.5 2 2.5 3

0 2 4 6 8 10

PureFlo 5.0" PolyPro Capsule

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

1.5" Tri Clamp fitting

0.3

0.6

1.0

3.05.0

30

10

50,70

PureFlo

Capsule

Filters

Vent & Drain

FittingFilter Media

Pore size

(Micron)Length

003 = 0.3 H = 1.5" 1H = 1/8" Hose barbs 1H = 1/8" Hose barbsSK 006 = 0.6 S = 2.5" 1NF = 1/8" FNPT 1NF = 1/8" FNPT

010 = 1.0 L = 5" 1Q = 1/8" Male Quick Coupling for Metal latch 1Q = 1/8" Male Quick Coupling for Metal latch -NY = Nylon Construction -OE = O-ring EPDM030 = 3.0 E= 7.5" 1QF = 1/8" Female Quick Coupling w/Metal latch 1QF = 1/8" Female Quick Coupling w/Metal latch -FB = Filling bell -ON = O-ring Nitrile050 = 5.0 K = 10" 2C= 1/4" Compression 2C= 1/4" Compression -FC = Filling bell w/Cap -OV = O-ring Viton100 = 10.0 2H = 1/4" to 1/2" Hose barbs 2H = 1/4" to 1/2" Hose barbs200 = 20.0 2HS = 1/4" to 3/8" Hose barbs 2HS = 1/4" to 3/8" Hose barbs300 = 30.0 2LF = Large Female Luer Lock fitting 2LF = Large Female Luer Lock fitting500 = 50.0 2N = 1/4" MNPT 2N = 1/4" MNPT700 = 70.0 2NF = 1/4" FNPT 2NF = 1/4" FNPT10X = 100.0 2Q = 1/4" Male Quick Coupling for Metal latch 2Q = 1/4" Male Quick Coupling for Metal latch15X = 150.0 2QF = 1/4" Female Quick Coupling w/Metal latch 2QF = 1/4" Female Quick Coupling w/Metal latch

2QFP = 1/4" Female Quick Coupling w/Plastic latch 2QFP = 1/4" Female Quick Coupling w/Plastic latch2QP = 1/4" Male Quick Coupling for Plastic latch 2QP = 1/4" Male Quick Coupling for Plastic latch3C = 3/8" Compression 3C = 3/8" Compression3H = 3/8" Hose Barb 3H = 3/8" Hose Barb 3HE = 3/8" Hose Barb Elbow 3HE = 3/8" Hose Barb Elbow3NF = 3/8" FNPT 3NF = 3/8" FNPT4C = 1/2" Compression 4C = 1/2" Compression 4H = 1/2" Hose Barb 4H = 1/2" Hose Barb 4N = 1/2" MNPT 4N = 1/2" MNPT4QP = 1/2" Male Quick Coupling for Plastic latch 4QP = 1/2" Male Quick Coupling for Plastic latchMT = 1/2" Tri clamps MT = 1/2" Tri clampsTC = 1-1/2" Tri clamp TC = 1-1/2" Tri clamp

Input Fitting Output Fitting Options

L = Female Luer Lock

-GP = Gamma stable polypropylene shell

P = PolyPro MediaP = M8 Threaded

Plug - Limited options

70mm Diameter Capsule N = No vent or

drain fittings-ETO = Ethylene oxide sterilization

-NI = No vent or drain inlet fitting

-NO = NO vent or drain Outlet fitting

-E = Polyethylene shell and HDPE media support for gamma sterilization

Example - SK Series Capsule, Luer Lock V/D, 2.5" Internal filter,10 micron PolyPropylene Media Capsule, Standard Grade, with 1.5" Tri-Clamp fittings would be SKLP100STCTC

Quick Couplings are molded Female Quick Coupling with Plastic latch w ll be threaded on compat ble with CPC (Colder) LinkTech and others.

O-Ring for Quick

Coupling

Blank = O-ring Silicon (Standard)

PreFilters

-G(pore Size)= Glass Fiber PreFilter

-P(pore Size)= PolyPro Media PreFilter

-S(pore Size) = PES PreFilter

PureFlo Polypropylene Filter Cartridge Ordering Guide

1H = 1/8" Hose barbs Luer Lock1NF = 1/8" FNPT Luer Lock2C = 1/4" Compression 1/4" Comp2H = 1/4" to 1/2" Hose barbs Luer Lock2HS = 1/4" to 3/8" Hose barbs Luer Lock2L = Large Female Luer Lock fitting Luer Lock2N = 1/4" MNPT Luer Lock2NF = 1/4" FNPT Luer Lock2Q = 1/4" Male Quick Coupling Luer Lock2QF = 1/4" Female Quick Coupling Luer Lock2QFP = 1/4" Female Quick Coupling with Plastic latch Luer Lock2QP = 1/4" Male Quick Coupling for Plastic latch Luer Lock3C = 3/8" Compression 1/4" Comp3H = 3/8" Hose Barb (future) Luer Lock3HE = 3/8" Hose Barb Elbow Luer Lock3NF = 3/8" FNPT Luer Lock4C = 1/2" Commpression 1/4" Comp4H = 1/2" Hose Barb (future) Luer Lock4N = 1/2" MNPT Luer Lock4QP = 1/2" Male Quick Coupling for Plastic latch Luer LockMT = 0.5" Tri clamps Luer LockTC = 1-1/2" Tri clamp Luer Lock

Inlet/Outlet Fittings

Vent and

Drain

fittings

Option: Plugged and Cut off Vent and/or Drains

Autoclavable & Sanitizable Capsules can be autoclaved 25 times at 257 F/125 C for 30 minutes or

chemically sanitized in situ using common sanitizing agents or hot water

at 194 F/90 C for a limited time (dependent on time and temperature). Capsules must not be in situ steam-sterilized.

Regulatory Compliance

Manufactured from materials that conform to the requirements of 21CFR Part 177 of the U.S. Code of Federal Regulations and USP Class VI Bio-

logical Test for Plastics.

Page 63

Page 65: ZenPure - Q-Test

Mini Depth Pleated PP Filter Capsules

(Depth PP Media on PP Construction)

ZenPure Z

en

Pu

re

High Contaminant Holding Filtration

PureFlo® Pleated Depth capsule filters are de-signed for filtration and clarification applications in the pharmaceutical, biotechnology, food and beverage, medical, chemical, and water world-wide. This family of products is particularly suit-able for the fluids that contain gels, colloidal sus-pensions, or high suspended solids.

Highly retentive graded porosity design removes particles by size – larger particles by the more open outer layers and smaller particles by the tighter inner layers. The outer layers act as a pre-filter while the inner layers provide the absolute rating at the specified pore size. This efficiently spreads the contaminants throughout the media matrix, thereby, resulting in superior contaminant holding capacity, lifetime, and lower pressure drop as compared to other depth media car-tridges.

Specifications Materials of Construction: Media: Non-Woven Polypropylene Media Supports: Polypropylene Cage, Core, End Caps: Polypropylene Sealing: Thermally bonded Fitting Connections: See ordering guide for the availability. (Custom adaptors available upon request) Nominal Dimensions: Lengths: 1.5”, 2.5”, 5”, 7.5” and 10”

Diameter: 2.75 in. (70mm)

Available Ratings: 0.5um, 1.0um, 1.5um, 2.5um, 4.5um, 10um, and 20um

Operating Conditions: Maximum Operating Pressure: Liquid: 5.5 bar (80psi) at 77°F/25°C Gas: 4.1 bar (60psi) at 77°F/25°C Maximum Forward Differential Pressure: 4.21 bar (60psi) at 68°F/20°C Maximum Reverse Differential Pressure: 2.1 bar (30 psi) at 68°F/20°C Minimum Burst Pressure: 8.3 bar (120psi) at 77°F/25°C Maximum Operating Temperature: 176°F (80°C)

Regulatory Compliance: The filters are constructed with polypropylene resins and filtration media in compliance with 21CFR Part 177 of the US Code of Federal Regulations and USP Class VI Biological Test for Plastic.

Applications Clarification Ink Gel Removal Beverages Yeast Removal Pharmaceuticals Fine Chemicals Biologics Plating Solutions Wine Beer Water

Page 64

Page 66: ZenPure - Q-Test

ZenPure Mini Depth Pleated PP Capsules

Your Local Distributor:

B15.1 Rev 2011.07

ZenPure

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

Specifications (cont.)

Autoclavable & Sanitizable: Capsules can be autoclaved 25 times at 257°F/125°C for 30 minutes or chemically sanitized in situ using common sanitizing agents or hot water at 194°F/90°C for a limited time (dependent on time and tem-perature). Capsules must not be in situ steam-sterilized.

PureFlo Mini Depth Pleated PP Filter Capsule Ordering Guide

0

1

2

3

4

5

0

0.04

0.08

0.12

0.16

0.2

0.24

0.28

0.32

0 0.5 1 1.5 2 2.5 3

0 2 4 6 8 10

PureFlo Mini Depth Pleated PP (2.5in) Capsule

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

1.5

2.5

4.5

10

0

0.5

1

1.5

2

2.5

3

3.5

4

0

0.05

0.1

0.15

0.2

0.25

0 0.5 1 1.5 2 2.5 3 3.5 4

0 5 10 15

PureFlo Mini Depth Pleated PP (5in) Capsule

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

1.5

2.5

4.510

0

1

2

3

4

5

6

0

0.05

0.1

0.15

0.2

0.25

0.3

0.35

0.4

0 0.5 1 1.5

0 0.8 1.6 2.4 3.2 4 4.8 5.6

PureFlo Mini Depth Pleated PP (1.5in) Capsule

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

1.5

2.5

4.5

10

PureFlo

Capsule FiltersFilter Media

Pore size

(Micron)Length Options

002 = 0.2um H = 1.5" 1H = 1/8" Hose barbs 1H = 1/8" Hose barbs005 = 0.5um S = 2.5" 1NF = 1/8" FNPT 1NF = 1/8" FNPT010 = 1.0um L= 5" 1Q = 1/8" Male Quick Coupling for Metal latch 1Q = 1/8" Male Quick Coupling for Metal latch -NY = Nylon Construction015 = 1.5um E= 7.5" 1QF = 1/8" Female Quick Coupling w/Metal latch 1QF = 1/8" Female Quick Coupling w/Metal latch -FB = Filling bell025 = 2.5um K = 10" 2C= 1/4" Compression 2C= 1/4" Compression -FC = Filling bell w/Cap045 = 4.5um 2H = 1/4" to 1/2" Hose barbs 2H = 1/4" to 1/2" Hose barbs100 = 10um 2HS = 1/4" to 3/8" Hose barbs 2HS = 1/4" to 3/8" Hose barbs200 = 20um 2LF = Large Female Luer Lock fitting 2LF = Large Female Luer Lock fitting

2N = 1/4" MNPT 2N = 1/4" MNPT2NF = 1/4" FNPT 2NF = 1/4" FNPT2Q = 1/4" Male Quick Coupling for Metal latch 2Q = 1/4" Male Quick Coupling for Metal latch2QF = 1/4" Female Quick Coupling w/Metal latch 2QF = 1/4" Female Quick Coupling w/Metal latch2QFP = 1/4" Female Quick Coupling w/Plastic latch 2QFP = 1/4" Female Quick Coupling w/Plastic latch2QP = 1/4" Male Quick Coupling for Plastic latch 2QP = 1/4" Male Quick Coupling for Plastic latch3C = 3/8" Compression 3C = 3/8" Compression3H = 3/8" Hose Barb 3H = 3/8" Hose Barb 3HE = 3/8" Hose Barb Elbow 3HE = 3/8" Hose Barb Elbow -OE = O-ring EPDM3NF = 3/8" FNPT 3NF = 3/8" FNPT -ON = O-ring Nitrile4C = 1/2" Compression 4C = 1/2" Compression -OV = O-ring Viton4H = 1/2" Hose Barb 4H = 1/2" Hose Barb 4N = 1/2" MNPT 4N = 1/2" MNPT4QP = 1/2" Male Quick Coupling for Plastic latch 4QP = 1/2" Male Quick Coupling for Plastic latchMT = 1/2" Tri clamps MT = 1/2" Tri clampsTC = 1-1/2" Tri clamp TC = 1-1/2" Tri clamp

Example - SK Series Capsule, 2.5" Internal filter,10 micron Depth PolyPropylene Media Capsule, Standard Grade, with 1.5" Tri-Clamp fittings would be SKDP100STCTC

Quick Couplings are molded, Female Quick Coupling with Plastic latch will be threaded on, compatible with CPC (Colder), LinkTech and others.

Input Fitting Output Fitting

SK-GP = Gamma stable polypropylene shell

DP = Depth PolyPro Media70mm Diameter

Capsule

-ETO = Ethylene oxide sterilization

-NI = No vent or drain inlet fitting

-NO = NO vent or drain Outlet fitting

-E = Polyethylene shell and HDPE media support for gamma sterilization

Blank = O-ring Silicon (Standard)

O-Ring for Quick

Coupling

Internal Cross Section

Page 65

Page 67: ZenPure - Q-Test

HEPA Filter Capsules

(99.997% efficiency at 0.3um)

ZenPure Z

en

Pu

re

Specifications Materials of Construction: Media: Non-Woven Polypropylene, Micro-Glass fiber, PTFE, Polyethylene Media Supports: Polypropylene Shell, Cage, Core, and End Caps: Polypropylene

Fitting Connections: Hose Barb, NPT, Compression Quick Couplings, and Sanitary. Any inlet/outlet combinations. (Custom adaptors available upon request)

Nominal Dimensions: Length: 1.5 in (68 mm), Length: 2.5 in (98 mm), Length: 5.0 in (153 mm), Length: 7.5 in (251mm), Length: 10 in (281mm),

Diameter: 2.88 in (73 mm)

Effective Filtration Area: 1.5 in - 0.65 ft2 (600 cm2), 2.5 in - 1.3 ft2 (1200 cm2), 5.0 in - 2.7 ft2 (2400 cm2), 10 in - 5.2 ft2 (4800 cm2)

Operating Conditions: Maximum Operating Pressure: Liquid: 5.5 bar (80psi) at 77°F/25°C Gas: 4.1 bar (60psi) at 77°F/25°C Maximum Forward Differential Pressure: 4.21 bar (60psi) at 68°F/20°C Maximum Reverse Differential Pressure: 2.1 bar (30 psi) at 68°F/20°C Minimum Burst Pressure: 8.3 bar (120psi) at 77°F/25°C Maximum Operating Temperature: 140°F/60°C

HEPA Rated: Ensures particulate-free air 99.997% retention of 0.3 µm DOP aerosol Pyrogenicity: <0.25 EU/ml using the LAL test method

Autoclavable & Sanitizable: Capsules can be autoclaved 25 times at 257°F/125°C for 30 minutes or chemically sanitized in situ using common sanitizing agents or hot water at 194°F/90°C for a limited time (dependent on time and temperature).

Capsules must not be in situ steam-sterilized.

Regulatory Compliance: The filters are constructed with polypropylene resins and filtration media in com-pliance with 21CFR Part 177 of the US Code of Federal Regulations and USP Class VI Biological Test for Plastic.

High-Efficiency Particulate Air and

Gas Filter

PureFlo® HEPA Capsules are designed for high retention and particle holding capac-ity for air and gas in the pharmaceutical, biotechnology, medical, chemical, food and beverage applications worldwide. This family of products is particularly suitable for a variety of gases with four different filtration media to choose from.

They are designed to provide bacteria, al-gae, fungal-free air for sterile applications such as fermentors or incubators. The capsules have a durable polypropylene housings. The media allows for high flow rates and low pressure drops.

Applications Tank Vent Air Filter

Vacuum pump Beverages

Fermentor Pharmaceuticals

Fine Chemicals Biologics

Incubator Wine

Beer Water

Page 66

Page 68: ZenPure - Q-Test

Your Local Distributor:

ZenPure

B15.2 Rev 2011.08

HEPA Filter Capsules

ZenPure

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

PureFlo MK Series HEPA Filter Capsule Ordering Guide

PureFlo

Capsule

Filters

Filter Media Surface Area Inlet Fitting Outlet Fitting Option

E = Polyethylene A = 200cm2 1C = 1/8" Compression 1C = 1/8" Compression

MKH F = PTFE B = 300cm2 1H = 1/8" Hose Barb 1H = 1/8" Hose Barb

G = Glass Fiber C = 400cm2 1Q = 1/8" Male Quick Coupling 1Q = 1/8" Male Quick Coupling

D = 500cm2

2C = 1/4" Compression 2C = 1/4" Compression2CE = 1/4" Compression Elbow 2CE = 1/4" Compression Elbow2H = 1/4" Hose barbs 2H = 1/4" Hose barbs2N = 1/4" MNPT 2N = 1/4" MNPT2NO = 1/4" MNPT+EP O-Ring 2NO = 1/4" MNPT+EP O-Ring

3H = 3/8" Hose Barb 3H = 3/8" Hose BarbLF = Female Luer Lock LF = Female Luer Lock LFE = Female Luer Lock Elbow LFE = Female Luer Lock ElbowMT = 1/2" Tri clamps MT = 1/2" Tri clamps

P = Polypropylene Media

Example - MKH Series PTFE HEPA 500cm2 1/4" Hose Barb I/O is MKHFD2H2H

60mm Diameter

-NO = No vent or Drain Outlet fitting

-N= No vent or Drain fittings

1QE = 1/8" Male Quick Coupling Elbow

1QE = 1/8" Male Quick Coupling Elbow

-NI = No vent or Drain inlet fitting

G and P Media

are only

available in

Surface Area

"C" (400cm2)

2QE = 1/4" Male Quick Coupling for Metal latch Elbow

2QE = 1/4" Male Quick Coupling for Metal latch Elbow

2QF = 1/4" Female Quick Coupling with Metal latch

2QF = 1/4" Female Quick Coupling with Metal latch

-GP = Gamma Stable Polypropylene Shell

-E = Polyethylene Shell and PET media support for Gamma Sterilization

2Q = 1/4" Male Quick Coupling for Metal latch

2Q = 1/4" Male Quick Coupling for Metal latch

PureFlo

Capsule

Filters

Filter Media Length Option

E = Polyethylene H = 1 5" 1H = 1/8" Hose barbs 1H = 1/8" Hose barbsSKH F = PTFE S = 2.5" 1NF = 1/8" FNPT 1NF = 1/8" FNPT

G = Glass Fiber L = 5" 1Q = 1/8" Male Quick Coupling for Metal latch 1Q = 1/8" Male Quick Coupling for Metal latchE = 7.5" 1QF = 1/8" Female Quick Coupling w/Metal latch 1QF = 1/8" Female Quick Coupling w/Metal latchK = 10" 2C = 1/4" Compression 2C = 1/4" Compression

2H = 1/4" to 1/2" Hose barbs 2H = 1/4" to 1/2" Hose barbs2HS = 1/4" to 3/8" Hose barbs 2HS = 1/4" to 3/8" Hose barbs2LF = Large Female Luer Lock fitting 2LF = Large Female Luer Lock fitting2N = 1/4" MNPT 2N = 1/4" MNPT2NF = 1/4" FNPT 2NF = 1/4" FNPT2Q = 1/4" Male Quick Coupling for Metal latch 2Q = 1/4" Male Quick Coupling for Metal latch2QF = 1/4" Female Quick Coupling w/Metal latch 2QF = 1/4" Female Quick Coupling w/Metal latch2QFP = 1/4" Female Quick Coupling w/Plastic latch 2QFP = 1/4" Female Quick Coupling w/Plastic latch2QP = 1/4" Male Quick Coupling for Plastic latch 2QP = 1/4" Male Quick Coupling for Plastic latch3C = 3/8" Compression 3C = 3/8" Compression3H = 3/8" Hose Barb 3H = 3/8" Hose Barb 3HE = 3/8" Hose Barb Elbow 3HE = 3/8" Hose Barb Elbow3NF = 3/8" FNPT 3NF = 3/8" FNPT4C = 1/2" Compression 4C = 1/2" Compression -OE = O-ring EPDM4H = 1/2" Hose Barb 4H = 1/2" Hose Barb -ON = O-ring Nitrile4N = 1/2" MNPT 4N = 1/2" MNPT -OV = O-ring Viton4QP = 1/2" Male Quick Coupling for Plastic latch 4QP = 1/2" Male Quick Coupling for Plastic latchMT = 1/2" Tri clamps MT = 1/2" Tri clampsTC = 1-1/2" Tri clamp TC = 1-1/2" Tri clamp

Example - 2.5" Glass Fiber HEPA rated Capsule with 1/2" Hose Barb fittings would be SKHGHS4H4H

M ale Quick Coup ings are molded, Female Quick Coupling with Plastic latch will be threaded on, compat ble w th CPC (Colder), LinkTech and other compatible couplings.

Input Fitting Output Fitting

70mm Diameter Capsule

-E = Polyethylene Shell and PET media support for Gamma Sterilization

-GP = Gamma Stable Polypropylene Shell

-N= No vent or Drain fittings

-NI = No vent or Drain inlet fitting

-NO = No vent or Drain Outlet fitting

Blank = O-ring Silicon (Standard)

O-Ring for Quick

Coupling

P = Polypropylene Media

PureFlo SK Series HEPA Filter Capsule Ordering Guide

MK Series Filter

SK Series Filter

Page 67

Page 69: ZenPure - Q-Test

PureFlo® Carbon Fiber / HEPA Capsules

ZenPure Z

en

Pu

re

PureFlo® Carbon Fiber / HEPA capsules are designed

to remove volatile organic compounds, hydrocarbons,

chlorine, color, and odors from gases and aqueous or

organic liquids. This fibrous carbon media is designed

for maximum flow and contaminant removal to elimi-

nate potential health hazards. The carbon fiber can be

followed by HEPA rated media to also filter the gas

while purifying it. The carbon fiber allows for highly

efficient contact time and adsorption capacity. Designed

with clean, durable polypropylene support structure to

provide superior down stream cleanliness.

No adhesives, binders, or surfactants are used in the

manufacturing process. Each capsule is manufactured

under tight process control to give you a uniform prod-

uct with every filter. These activated carbon filters are

available in a range of lengths and connections to suit

your individual purification and filtration needs.

Applications

Gas purification Liquid purification

Fine Chemicals Water

Reagent Purification Pharmaceuticals

Odor removal Biologics

Vacuum pumps Outlet exhaust

Materials of Construction Media: Fibrous Activated Carbon and HEPA media

Membrane Supports: Polypropylene

Cage, Core, End Caps: Polypropylene

Fitting Connections: MNPT, FNPT, Compression,

Sanitary Flange, Hose Barb

Dimensions (TC fittings) Length: 1.5 in (128 mm) Length: 2.5 in (155 mm)

Length: 5.0 in (210 mm) Length: 7.5 in (270 mm)

Length: 10 in (340mm)

Diameter: 2.75 in (70 mm)

Effective Purification volume 1.5 in 0.65 grams 2.5 in 1.3 grams

5.0 in 2.7 grams 7.5 in 4.0 grams 10.0 in 5.2 grams

Operating Conditions Maximum Operating Pressure:

Liquid: 5.5 bar (80psi) at 77°F/25°C

Gas: 4.1 bar (60psi) at 77°F/25°C

Minimum Burst Pressure:

8.3 bar (120psi) at 77°F/25°C

Maximum Forward Differential Pressure:

4.21 bar (60psi) at 68°F/20°C

Maximum Reverse Differential Pressure:

2.1 bar (30psi) at 68°F/20°C

Maximum Operating Temperature: 140°F/60°C

Features Benefits

■ Carbon Fiber ■ Greater surface area to trap VOC’s than granular carbon

■ Faster kinetics for VOC absorption since the VOCs do not need to travel

as far in the structure as granular carbon

■ Light weight and high surface area, for lower pressure drop

■ more porous for 100 times more accessible for VOC than granular

activated carbon

■ HEPA filtration ■ Removes 0.3 µm in size with an efficiency rating of 99.97%.

■ Low hold-up volume reduces chemical waste

■ Reduced handling of hazardous chemicals

■ Compact ■ Disposable unit to easily change out

■ Several fittings to choose from

Autoclavable & Sanitizable Capsules can be autoclaved 25 times at 257°F/125°C for 30 minutes or chemically sanitized in situ using common sanitizing agents or hot water at 194°F/90°C for a limited time (dependent on time and temperature). Capsules must not be in situ steam-sterilized.

Page 68

Page 70: ZenPure - Q-Test

ZenPure PureFlo® Carbon Fiber / HEPA Capsules

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

B15.5 Rev 2011.08

PureFlo Carbon Fiber Filter Capsule Ordering Guide

Regulatory Compliance

Manufactured from materials that conform to the re-

quirements of 21CFR Part 177 of the U.S. Code of Fed-

eral Regulations and USP Class VI Biological test for

Plastic

PureFlo

Capsule

Filters

Filter MediaHEPA Filter

Media

Internal HEPA

FilterCapsule Length Option

1H = 1/8" Hose barbs 1H = 1/8" Hose barbsSK E = Polyethylene H = 1.5" H = 1.5"* 1NF = 1/8" FNPT 1NF = 1/8" FNPT

F = PTFE S = 2.5" S = 2.5" 2C = 1/4" Compression 2C = 1/4" CompressionG = Glass Fiber L = 5" 2H = 1/4" to 1/2" Hose barbs 2H = 1/4" to 1/2" Hose barbsP = Polypropylene E= 7.5" 2HS = 1/4" to 3/8" Hose barbs 2HS = 1/4" to 3/8" Hose barbs

K = 10" 2L = Large Female Luer Lock fitting 2L = Large Female Luer Lock fitting2N = 1/4" MNPT 2N = 1/4" MNPT2NF = 1/4" FNPT 2NF = 1/4" FNPT2Q = 1/4" Male Quick Coupling for Metal latch 2Q = 1/4" Male Quick Coupling for Metal latch2QF = 1/4" Female Quick Coupling w/ Metal latch 2QF = 1/4" Female Quick Coupling w/ Metal latch2QFP = 1/4" Female Quick Coupling w/ Plastic latch 2QFP = 1/4" Female Quick Coupling w/ Plastic latch2QP = 1/4" Male Quick Coupling for Plastic latch 2QP = 1/4" Male Quick Coupling for Plastic latch3C = 3/8" Compression 3C = 3/8" Compression3H = 3/8" Hose Barb 3H = 3/8" Hose Barb3HE = 3/8" Hose Barb Elbow 3HE = 3/8" Hose Barb Elbow3NF = 3/8" FNPT 3NF = 3/8" FNPT4C = 1/2" Compression 4C = 1/2" Compression4H = 1/2" Hose Barb 4H = 1/2" Hose Barb -OE = O-ring EPDM4N = 1/2" MNPT 4N = 1/2" MNPT -ON = O-ring Nitrile4QP = 1/2" Male Quick Coupling for Plastic latch 4QP = 1/2" Male Quick Coupling for Plastic latch -OV = O-ring VitonMT = 1/2" Tri clamps MT = 1/2" Tri clampsTC = 1-1/2" Tri clamp TC = 1-1/2" Tri clamp

Blank = for Carbon only

O-Ring for Quick

Coupling

Input Fitting

M ale Quick Couplings are molded, Female Quick Coupling with Plastic latch w ll be threaded on, compatible with CPC (Colder), LinkTech and other compatible couplings.

Output Fitting

Example - 5" Carbon/HEPA capsule with a Glass Fiber HEPA 1.5" internal filter with 1/2" Hose Barb fittings I/O would be SKCHGHL4H4H

CH = Activated Carbon Fiber with HEPA Filter *

70mm Diameter Capsule

-NI = No vent or Drain inlet fitting

-E = Polyethylene Shell and PET media support for Gamma Sterilization

Blank = for Carbon only

Blank = O-ring Silicon (Standard)

-N= No vent or Drain fittings

-GP = Gamma Stable Polypropylene Shell

* - Size H for

Carbon Fiber

only

-NO = No vent or Drain Outlet fitting

C = Activated Carbon Fiber only

PureFlo

Capsule

Filters

Filter Media Option

MK

2QF = 1/4" Female Quick Coupling with Metal latch

2QF = 1/4" Female Quick Coupling with Metal latch

2NO = 1/4" MNPT+EP O-Ring2N = 1/4" MNPT2H = 1/4" Hose barbs

C = Activated Carbon Fiber

1H = 1/8" Hose Barb1Q = 1/8" Male Quick Coupling

1QE = 1/8" Male Quick Coupling Elbow

60mm Diameter Capsule

1QE = 1/8" Male Quick Coupling Elbow

2CE = 1/4" Compression Elbow2H = 1/4" Hose barbs2N = 1/4" MNPT2NO = 1/4" MNPT+EP O-Ring

1C = 1/8" Compression

2QE = 1/4" Male Quick Coupling for Metal latch Elbow

3H = 3/8" Hose BarbLF = Female Luer Lock LFE = Female Luer Lock Elbow

2Q = 1/4" Male Quick Coupling for Metal latch

MT = 1/2" Tri clamps

2QE = 1/4" Male Quick Coupling for Metal latch Elbow

3H = 3/8" Hose Barb

Inlet Fitting Outlet Fitting

1C = 1/8" Compression1H = 1/8" Hose Barb1Q = 1/8" Male Quick Coupling

2C = 1/4" Compression

LF = Female Luer Lock LFE = Female Luer Lock ElbowMT = 1/2" Tri clamps

2C = 1/4" Compression2CE = 1/4" Compression Elbow

Example - MKL Series Capsule Carbon Fiber Capsule with 1/4" Hose Barb fittings would be MKC2H2H

-N = No vent or Drain fittings

-NI = No vent or Drain inlet fitting

-NO = No vent or Drain Outlet fitting

-GP = Gamma Stable Polypropylene Shell

-E = Polyethylene Shell and PET media support for Gamma Sterilization

2Q = 1/4" Male Quick Coupling for Metal latch

Page 69

Page 71: ZenPure - Q-Test

PureFlo Lenticular Cloud Filters

(Cellulose Media)

ZenPure Z

en

Pu

re

Unique Depth Filtration

PureFlo® Lenticular Cloud Filters have been de-signed for simple, quick, and efficient filtration of fluids used in laboratory, pilot, and small-scale applications. The family of products is par-ticularly suitable for high loading liquid applica-tions. The compact design of the filters with re-spect to the filtration area, reduces hold-up vol-ume and optimizes performance. Eleven differ-ent pore size options can be placed in an all-polypropylene construction for excellent chemi-cal compatibility. There are numerous different fitting options for each of the different filters.

The cellulose depth media is structured in a stacked disc format to provide optimal flow. No adhesives, binders, or surfactants are used in the construction process. The unit is thermally-sealed to ensure integrity.

There are several filter options available for laboratory testing to production:

D65 (Disc capsule) SKL/ SKV (Mini Capsule) Mini Cartidge ZenCap (Full Size Capsule) Full Size Cartridge

Applications Vaccines Chemicals Lab scale testing Purified Protein Bio Bags Pharmaceuticals Fine Chemicals Biologics Vent Filter Scale up processing Water Cell Separation

SHEET RETENTION AND PERMEABILITY RATINGS

(s

eta

Rn

oitn

ete

Rl

ani

mo

)m

FilterGrades

0

6.0

8.0

7.0

5.0

4.0

3.0

2.0

1.0

9.0

10.0

6.0

4 0

3.0

2.5

1.5

0.850.60

0.500.400.15

mL[

ytilib

ae

mre

P2-

nim

1-]

FilterGrades

0

1500

2000

1750

1250

1000

750

500

250

2250

2020

1390

950

640

435

295200

956444

10.0

4340

0.15 0.40 0.50 0.60 0.85 1.5 2.5 3.0 4.0 6.0

Page 70

Page 72: ZenPure - Q-Test

ZenPure PureFlo Lenticular Cloud Filters

Operating Conditions: Max. Working Pressure:

PP/HDPE/PVC 80 PSID @ 77°F/25°C (5.5 bar) Gamma PP 45 PSID @ 77°F/25°C (3.1 bar)

Minimum burst pressure: PP/HDPE: 120 PSID @ 77° F/25°C (8.3 bar) Gamma PP: 60 PSID @ 77°F/25°C (4.1 bar)

Maximum forward differential pressure: 60 PSID (4.1 bar) at 68°F (20°C) 30 PSID (2.1 bar) at 176°F (80°C) Maximum reverse differential pressure: 30 PSIG (2.1 bar) at 68°F (20°C)

Maximum Operating Temperature: PP & Gamma PP: 176°F/80°C HDPE: 140°F/60°C PVC: 122°F/50°C

Autoclavable & Sanitizable: Capsules can be autoclaved 3 times at 257°F/125°C for 30 minutes or chemically sanitized in situ using common sanitizing agents or hot water at 194°F/90°C for a limited time (dependent on time and tem-perature). Capsules must not be in situ steam-sterilized.

D65 Disc Capsule

PureFlo® D65 Lenticular Cloud capsules with cellulosic media is available in multiple filtra-tion pore sizes. The small size of the D65 al-lows for laboratory and small scale testing for proof of filtration. The inlet and outlet ports are available with 18 fittings options, eliminat-ing the need for transition connectors. This self contained disposable filter can be supplied with your choice of 11 pore sizes to optimize your filtration process.

015 = 0.15 1H = 1/8" Hose Barb 1H = 1/8" Hose Barb Blank = Polypropylene Shell040 = 0.40 1NF = 1/8" FNPT 1NF = 1/8" FNPT -GP = Gamma stabilized PP

ll050 = 0.50 1Q = 1/8" Male Quick Coupling 1Q = 1/8" Male Quick Coupling -NY = Nylon Shell060 = 0.60 1QF = 1/8" Female Quick 1QF = 1/8" Female Quick Coupling085 = 0.85 2H = 1/4"-5/16" Hose Barb 2H = 1/4"-5/16" Hose Barb150 = 1.50 2N = 1/4" MNPT 2N = 1/4" MNPT250 = 2.50 2NF = 1/4" FNPT 2NF = 1/4" FNPT -1 = Single Bagged300 = 3.00 -NV= No vent fitting400 = 4.00 -FB = Filling Bell (with 2H 600 = 6.00 -FC = Filling Bell with Cap

01X = 10.0* -BLK = Black PP Shell3H = 5/16-3/8" Hose Barb 3H = 5/16-3/8" Hose Barb3N = 3/8" MNPT 3N = 3/8" MNPT3NF = 3/8" FNPT 3NF = 3/8" FNPT4N = 1/2" MNPT 4N = 1/2" MNPTFV = Female Ventilator FV = Female VentilatorLF = Female Luer Lock LF = Female Luer Lock MT = 1/2" Tri Clamp MT = 1/2" Tri Clamp -OE = O-ring EPDMMV = Male Ventilator MV = Male Ventilator -ON = O-ring NitrileTC = 1.5" Tri Clamp TC = 1.5" Tri Clamp -OV = O-ring Viton

Nominal Pore

size (Micron)

* - Does not

have DE

Example – 1.50 Micron Celulose Filter Media with 1/2" tri clamp fittings would be D65CEP150MTMT

CEP = Celulose with DE Blend

Blank = O-ring Silicon (Standard)

D65

Lenticular

Cloud =

65mm Disc filter

-E = Polyethylene Shell and HDPE media support for gamma sterilization

2Q = 1/4" Male Quick Coupling for Metal latch

2Q = 1/4" Male Quick Coupling for Metal latch

2QF = 1/4" Female Quick Coupling with Metal latch

2QF = 1/4" Female Quick Coupling with Metal latch

-ETO = Ethylene oxide sterilization

Oring for Quick Coupling

PureFlo D65

Lenticular

Cloud Disc

Filters

Filter Media Input Fitting Output Fitting Options

Specifications

Materials of Construction: Media: Cellulose Media Supports: Polypropylene Shell: Polypropylene Sealing: Thermally-welded Effective Filtration Area : 4in2 (26cm2) Dimensions: 65mm (2.87in) Available Ratings: 0.15um to 10um

Regulatory Compliance: The filters are constructed with polypropylene resins and fil-

tration media in compliance with 21CFR of the US Code of Federal Regulations and USP Class VI Biological Test for Plas-tic. (Except Blk PP and PVC)

PureFlo D65 Lenticular Cloud Filter Capsule Ordering Guide

A9.1 Rev 2011.08

Page 71

Page 73: ZenPure - Q-Test

ZenPure PureFlo Lenticular Cloud Filters

PureFlo SKV Lenticular Cloud Filter Capsule Ordering Guide

Operating Conditions: Maximum Operating Pressure: Liquid: 5.5 bar (80psi) at 77°F/25°C Gas: 4.1 bar (60psi) at 77°F/25°C Minimum Burst Pressure: 8.3 bar (120psi) at 77°F/25°C Maximum Forward Differential Pressure: 5 bar (72psi) at 68°F/20°C Maximum Reverse Differential Pressure: 2.1 bar (30psi) at 68°F/20°C

Maximum Operating Temperature: 140°F/60°C Autoclavable & Sanitizable:

Capsules can be autoclaved 3 times at 257°F/125°C for 30 minutes or chemically sanitized in situ using common sanitizing agents or hot water at 194°F/90°C for a limited time (dependent on time and temperature). Capsules must not be in situ steam-sterilized.

Specifications

Materials of Construction: Media: Cellulose Media Supports: Polypropylene Shell: Polypropylene Sealing: Thermally-welded Effective Filtration Area : 18.6-140in2 (120-900cm2) Dimensions: 2.75 in (70mm) Available Ratings: 0.15um to 10um

Regulatory Compliance: The filters are constructed with poly-propylene resins and filtration media in compliance with 21CFR of the US Code of Federal Regulations and USP Class VI Biological Test for Plastic.

SKV Series Capsule

PureFlo® SKV Lenticular Cloud capsules with cellulosic media is the next size up with 5 cap-sule sizes to choose ranging from 120-900 cm2. This medium size capsule allows for pilot to medium scale production. The inlet and outlet ports are available with 17 fittings op-tions, eliminating the need for transition con-nectors. The SKV series capsule has an ad-justable, easy to turn upstream bleed values with an o-ring seal and hose barb connections allowing for easy process control. These cap-sules eliminate the time and expense associ-ated with assembling and cleaning stainless steel housings.

PureFlo

Capsule

Filters

Filter MediaNominal Pore

size (Micron)

Effective

Media Area Option

015 = 0.15 H = 120cm2 1H = 1/8" Hose barbs 1H = 1/8" Hose barbsSKV 040 = 0.40 S = 250cm2 1NF = 1/8" FNPT 1NF = 1/8" FNPT

050 = 0.50 L = 450cm2 1Q = 1/8" Male Quick Coupling w/Metal Latch 1Q = 1/8" Male Quick Coupling w/Metal Latch -E = Polyethylene Shell 060 = 0.60 E= 700cm2 1QF = 1/8" Female Quick Coupling with Metal latch 1QF = 1/8" Female Quick Coupling with Metal latch085 = 0.85 K = 900cm2 2H = 1/4" Hose barb 2H = 1/4" Hose barb150 = 1.50 2N = 1/4" MNPT 2N = 1/4" MNPT -FB = Filling Bell250 = 2.50 2NF = 1/4" FNPT 2NF = 1/4" FNPT -FC = Filling Bell w/Cap300 = 3.00 2Q = 1/4" Male Quick Coupling for Metal latch 2Q = 1/4" Male Quick Coupling for Metal latch400 = 4.00 2QF = 1/4" Female Quick Coupling w/Metal latch 2QF = 1/4" Female Quick Coupling w/Metal latch600 = 6.00 2QFP = 1/4" Female Quick Coupling w/Plastic latch 2QFP = 1/4" Female Quick Coupling w/Plastic latch01X = 10.0* 2QP = 1/4" Male Quick Coupling for Plastic latch 2QP = 1/4" Male Quick Coupling for Plastic latch

3H = 3/8" Hose Barb 3H = 3/8" Hose Barb3NF = 3/8" FNPT 3NF = 3/8" FNPT4H = 1/2" Hose Barb 4H = 1/2" Hose Barb4N = 1/2" MNPT 4N = 1/2" MNPT4QP = 1/2" Male Quick Coupling for Plastic latch 4QP = 1/2" Male Quick Coupling for Plastic latch O-Ring for Quick Coupling

MT = 1/2" Tri clamps MT = 1/2" Tri clampsTC = 1-1/2" Tri clamp TC = 1-1/2" Tri clamp

-OE = O-ring EPDM-ON = O-ring Nitrile-OV = O-ring Viton

Input Fitting Output Fitting

Blank = Polypro construction

-GP = Gamma stable polypropylene shell

-ETO = Ethylene oxide sterilization

-N= No vent or drain fittings

70mm Diameter Capsule

w/Bleed valve

-NI = No vent or drain inlet fitting

-NO = No vent or drain Outlet fitting

Example - PureFlo SKV Lenticular Cloud Series Capsule Celulose with DE 0.40um 250cm2 3/8" Hose barb I/O would be SKVCE0403H3H

Quick Couplings are molded on. Female Quick Coupling with Plastic latch will be threaded on. Compatible with CPC (Colder) LinkTech and others.

CEP = Celulose with

DE Blend

* - Does not

have DE

Blank = O-ring Silicon (Standard)

b15.8.1 Rev 2011.08

Page 72

Page 74: ZenPure - Q-Test

ZenPure PureFlo Lenticular Cloud Filters

PureFlo SKL Lenticular Cloud Filter Capsule Ordering Guide

Operating Conditions: Maximum Operating Pressure: Liquid: 5.5 bar (80psi) at 77°F/25°C

Gas: 4.1 bar (60psi) at 77°F/25°C Minimum Burst Pressure: 8.3 bar (120psi) at 77°F/25°C Maximum Forward Differential Pressure: 4.21 bar (60psi) at 68°F/20°C Maximum Reverse Differential Pressure: 2.1 bar (30psi) at 68°F/20°C

Maximum Operating Temperature: 140°F/60°C

Autoclavable & Sanitizable: Capsules can be autoclaved 3 times at 257°F/125°C for 30 minutes or chemically sanitized in situ using common sanitiz-ing agents or hot water at 194°F/90°C for a limited time (dependent on time and temperature). Capsules must not be in situ steam-sterilized

Specifications

Materials of Construction: Media: Cellulose Media Supports: Polypropylene Shell: Polypropylene Sealing: Thermally-welded

Effective Filtration Area : 18.6-140in2 (120-900cm2)

Dimensions: 2.75 in (70mm)

Available Ratings: 0.15um to 10um

Regulatory Compliance: The filters are constructed with polypropyl-ene resins and filtration media in compli-ance with 21CFR of the US Code of Federal Regulations and USP Class VI Biological Test for Plastic.

SKL Series Capsule

PureFlo® SKL Lenticular Cloud capsules with cellulosic media has 5 capsule sizes to choose from. This is a wide range of filtration area from 120-900 cm2. This medium size capsule allows for pilot to medium scale production. The inlet and outlet ports are available with 17 fittings options, eliminating the need for tran-sition connectors. The SKL series capsule has luer lock upstream vent and drain connec-tions, allowing for easy process control. These capsules eliminate the time and expense asso-ciated with assembling and cleaning stainless steel housings.

PureFlo

Capsule

Filters

Capsule VersionFilter

Media

Nominal

Pore size

(Micron)

Effective

Media Area Option

015 = 0.15 H = 120cm2 1H = 1/8" Hose barbs 1H = 1/8" Hose barbsSK 040 = 0.40 S = 250cm2 1NF = 1/8" FNPT 1NF = 1/8" FNPT

050 = 0.50 L = 450cm2 1Q = 1/8" Male Quick Coupling w/Metal Latch 1Q = 1/8" Male Quick Coupling w/Metal Latch -E = Polyethylene Shell 060 = 0.60 E= 700cm2 1QF = 1/8" Female Quick Coupling with Metal lat 1QF = 1/8" Female Quick Coupling with Metal la085 = 0.85 K = 900cm2 2C = 1/4" Compression 2C = 1/4" Compression150 = 1.50 2H = 1/4" to 1/2" Hose barbs 2H = 1/4" to 1/2" Hose barbs -FB = Filling Bell250 = 2.50 2HS = 1/4" to 3/8" Hose barbs 2HS = 1/4" to 3/8" Hose barbs -FC = Filling Bell w/Cap300 = 3.00 2LF = Large Female Luer Lock fitting 2LF = Large Female Luer Lock fitting400 = 4.00 2N = 1/4" MNPT 2N = 1/4" MNPT600 = 6.00 2NF = 1/4" FNPT 2NF = 1/4" FNPT01X = 10.0* 2Q = 1/4" Male Quick Coupling for Metal latch 2Q = 1/4" Male Quick Coupling for Metal latch -N= No vent or drain

2QF = 1/4" Female Quick Coupling with Metal lat 2QF = 1/4" Female Quick Coupling with Metal la2QFP = 1/4" Female Quick Coupling with Plastic 2QFP = 1/4" Female Quick Coupling with Plastic 2QP = 1/4" Male Quick Coupling for Plastic latch 2QP = 1/4" Male Quick Coupling for Plastic latch3C = 3/8" Compression 3C = 3/8" Compression3H = 3/8" Hose Barb 3H = 3/8" Hose Barb3HE = 3/8" Hose Barb Elbow 3HE = 3/8" Hose Barb Elbow3NF = 3/8" FNPT 3NF = 3/8" FNPT O-Ring for Quick

4C = 1/2" Compression 4C = 1/2" Compression4H = 1/2" Hose Barb 4H = 1/2" Hose Barb4N = 1/2" MNPT 4N = 1/2" MNPT -OE = O-ring EPDM4QP = 1/2" Male Quick Coupling for Plastic latch 4QP = 1/2" Male Quick Coupling for Plastic latch-ON = O-ring NitrileMT = 1/2" Tri clamps MT = 1/2" Tri clamps -OV = O-ring VitonTC = 1-1/2" Tri clamp TC = 1-1/2" Tri clamp

70mm Diameter Capsule

-NI = No vent or drain inlet fitting

-NO = No vent or drain Outlet fitting

Example - PureFlo SKL Lenticular Series Capsule Celulose with DE 0.40um 250cm2 3/8" Hose barb I/O would be SKLCE0403H3H

Blank = O-ring Silicon (Standard)

* - Does not

have DE

Input Fitting

(not all fittings avalible in all options)Output Fitting

-GP = Gamma stable polypropylene shell

Blank = Polypro construction

P = M8 Plug or 1/4" Compression fitting Vent/Drain -ETO = Ethylene oxide

sterilization

CEP = Celulose with DE Blend

L = Luer Lock Vent/Drain

Quick Couplings are molded on. Female Quick Coupling with Plastic latch will be threaded on. Compatible with CPC (Colder) LinkTech and others.

b15.8.2 Rev 2011.08

Page 73

Page 75: ZenPure - Q-Test

ZenPure PureFlo Lenticular Cloud Filters

Mini-Cartridge Series

PureFlo® Lenticular Cloud Mini-cartridges with cellulosic media has 3 filter sizes to choose ranging from 120-900 cm2. This size cartridge allows for pilot to medium scale production. These filters are available with the 7 most common configuration options for your hous-ings. These cartridges can be quickly and eas-ily installed.

The PureFlo Lenticular Cloud Mini-cartridges are highly retentive, designed for high loading applications. The filter is made using cellulose media with an all polypropylene construction. They are well suited for critical applications where superior flow, lifetime, and holding ca-pacity are required. No additional adhesives, binders, or surfactants are used in the manu-facturing process.

PureFlo Mini

Lenticular Cloud

Filter Cartridges

Removal Rating

(micron)End Modifications Length

O-Ring / Gasket

MaterialsPackage Qty

015 = 0.15 A = 116 Inner O-Ring H = 1.5" E = EPDM 2P = 2pc/ pack (5")040 = 0.40 C = 015 O-Ring S = 2.5" N = Buna N050 = 0.50 D = 1/2" MNPT L= 5" S = Silicone060 = 0.60 E = 118 O-Ring U = TES085 = 0.85 F = Flange* V = Fluro-Elastomer Option

150 = 1.50 O = O-Ringless - 5 = SS Insert250 = 2.50300 = 3.00 N = 116 Inner Housing Seal400 = 4.00600 = 6.00

01X = 10.0*

* - Does not

have DE

MCEP = Mini Cellulosic Media

3P = 3pc/ pack (1.5" and 2.5")

Example - A 3 pack of 2.5", 3 micorn filters with 116 Internal EPDM o-ring would be MCEP300 ASE3P

* - F end mondification is compatible to fit in a PALL SealKleenTM

Housing, **- M end modification is compatible to it in a Millipore OptiSealTM Housing

M = 123 O-Rings with hold down tabs**

S = 116 Inner O-Ring w/locking groove

PureFlo Mini Lenticular Cloud Filter Cartridge Ordering Guide

Specifications

Materials of Construction: Media: Cellulose Media Supports: Polypropylene Shell: Polypropylene Sealing: Thermally-welded Effective Filtration Area : 18.6-140in2 (120-900cm2) Dimensions: 2.2 in (56mm) Available Ratings: 0.15um to 10um

Operating Conditions: Maximum Forward Differential Pressure: 3 bar (43.5 psid) at 20°C Maximum Reverse Differential Pressure: 2.0 bar (29 psid) at 20°C Maximum Operating Temperature: 140°F/60°C

Autoclavable & Sanitizable: Capsules can be autoclaved 3 times at 257°F/

125°C for 30 minutes or chemically sanitized in situ using common sanitizing agents or hot water at 194°F/90°C for a limited time (dependent on time and temperature).

Regulatory Compliance: The filters are constructed with polypropylene

resins and filtration media in compliance with 21CFR of the US Code of Federal Regulations and USP Class VI Biological Test for Plastic.

b15.8.3 Rev 2011.08

Page 74

Page 76: ZenPure - Q-Test

ZenPure PureFlo Lenticular Cloud Filters

PureFlo Glass Micro-fiber

Filter Cartridges

Removal Rating

(micron)End Modifications Length

O-Ring / Gasket

MaterialsPackage Qty Inserts

015 = 0.15 0 = 222 O-Ring Flat 1 - 10" E = EPDM 1 = 1pc/ pack Blank = Standard

040 = 0.40 5 = 222 O-Ring Spear 2 - 20" N = Buna N - 5 = SS Insert

050 = 0.50 6 = 226 O-Ring Flat 3 - 30" S = Silicone

060 = 0.60 7 = 226 O-Ring Spear 4 - 40" V = Viton

085 = 0.85 F = DOE Flat Gasket 5 = 5" T = TEV*

150 = 1.50 S = SOE Flat Gasket 9 = 9.75" U = TES*

250 = 2.50 Z = SOE Internal 213 O-ring Flat **

300 = 3.00400 = 4.00600 = 6.0001X = 10.0*

CEP = Cellulosic Media

* - Does not

have DE

Example - Cellulosic Media Cartridge, 10", 3.0 micron cartridge, w ith 2-222 Silicone o-ring, Flat end cap, and no insert w ould be CEP3001S1

* - not av ailable in Code Z ** - only av ailable in 5", 10" and 20"

Lenticular Cloud Cartridge Series

PureFlo® Lenticular Cloud cartridges with cel-lulosic media can be made from 5-40 inches. This full size cartridge allows for manufactur-ing production. This filter can be incorporated in a standard housing. A special Lenticular

housing is not required for this filter. They can also be incorporated into multi-round housings for additional filtration area.

The PureFlo Lenticular Cloud cartridges are highly retentive, designed for high loading ap-plications. The filter is made using cellulose media with an all polypropylene construction. They are well suited for critical applications where superior flow, lifetime, and holding ca-pacity are required. No additional adhesives, binders, or surfactants are used in the manu-facturing process.

ZenCap Lenticular Cloud Filter Cartridge Ordering Guide

Specifications Materials of Construction: Media: Cellulose Media Supports: Polypropylene Shell: Polypropylene Sealing: Thermally-welded Effective Filtration Area: 155-620in2 (1000-4000cm2) Dimensions: 2.75 in (70mm) Available Ratings: 0.15um to 10um

Operating Conditions: Maximum Operating Pressure: Liquid: 5.5 bar (80psi) at 77°F/25°C Gas: 4.1 bar (60psi) at 77°F/25°C Minimum Burst Pressure: 8.3 bar (120psi) at 77°F/25°C Maximum Forward Differential Pressure: 5 bar (72psi) at 68°F/20°C Maximum Reverse Differential Pressure: 2.1 bar (30psi) at 68°F/20°C

Maximum Operating Temperature: 140°F/60°C

Autoclavable & Sanitizable: Capsules can be autoclaved 3 times at 257°F/ 125°C for

30 minutes or chemically sanitized in situ using common sanitizing agents or hot water at 194°F/90°C for a limited time (dependent on time and temperature).

Regulatory Compliance: The filters are constructed with polypropyl-

ene resins and filtration media in compliance with 21CFR of the US Code of Federal Regulations and USP Class VI Biological Test for Plastic.

b15.8.5 Rev 2011.08

Page 75

Page 77: ZenPure - Q-Test

ZenPure PureFlo Lenticular Cloud Filters

ZenCap 10-40 inch Disposable

PureFlo® ZenCap Lenticular Cloud capsules with cellulosic media is a full size capsule. Sizes range from 10-40 inches in length. This full size capsule allows for manufacturing production. The inlet and outlet ports are available with 9 fittings options that can be mixed and matched, eliminating the need for transition connectors. The ZenCap series capsule has an adjustable, easy to turn up and downstream bleed value with an o-ring seal and hose barb connections allowing for easy process control. These capsules eliminate the time and expense associated with as-sembling and cleaning stainless steel housings.

They can be built in a T-style or In-line configuration. The filtra-tion shell is an all polypropylene construction that provides ex-cellent chemical compatibility with low extractables. No adhe-sives, binders, or surfactants are used in the manufacturing process.

ZenCap

Capsule SeriesConfiguration Length Filter Media Pore size (Micron) Vents ** Input Fitting Output Fitting Construction Material

1 - 10" 015 = 0.15 A = No v ents 3H = 3/8" Hose Barb 3H = 3/8" Hose Barb Blank = Poly propy lene

L I = In-Line* 2 - 20" 040 = 0.40 B = 1/2" Sanitary v ent 4H = 1/2-9/16" Hose Barb -E = Poly ethy lene

3 - 30" 050 = 0.50 4Q = 1/2" Male Quick Connect 4Q = 1/2" Male Quick Connect

4 - 40" 060 = 0.60 5H = 5/8" Hose Barb 5H = 5/8" Hose Barb

085 = 0.85 6H = 3/4" (19mm) Hose Barb 6H = 3/4" (19mm) Hose Barb -N = Ny lon

150 = 1.50 8H = 1" (25mm) Hose Barb 8H = 1" (25mm) Hose Barb

250 = 2.50 4QP = 1/2" Male Quick connect 4QP = 1/2" Male Quick connect

300 = 3.00 TC = 1-1/2" Tri-Clamp TC = 1-1/2" Tri-Clamp

400 = 4.00600 = 6.0001X = 10.0*

G = Inlet 1/4" Bleed Valv e O-Rings

H = Outlet 1/4" Bleed Valv e

-OE = O-Ring EPDM

-ON = O-Ring Nitrile

-OV = O-Ring Viton

D = 1/2" Sanitary v ent, w ith

Inlet 1/4" Bleed Valv e

E = 1/2" Sanitary v ent, w ith

dow n stream 1/4" Bleed Valv e

F = Inlet and Outlet 1/4" Bleed

Valv e

90mm Diameter

Capsule w ith

Bleed Valv e

* Av ailable in

2011

Example 1 - ZenCAP L Series Capsule, T-Line, Cellulose 1.5um, 20" filter, w ith all v ent and drains, 1.5" Tri-Clamp fittings I/O, w ould be LT2CEP150CTCTC

Example 2 - ZenCAP L Series Capsule, T-Line, Cellulose 1.5um, 10" filter, w ith all v ent and drains, 1.5" Tri-Clamp fittings I/O, w ould be LT1CEP150CTCTC

**Note: /4" Drain bleed Valve standard on all filters Except for option A

Blank = O-Ring Silicon

(Standard)* - Does not

have DE

T = T-LineC = 1/2" Sanitary vent, with

Inlet and Outlet 1/4" Bleed

Valve

-GP = Gamma Stable

Poly propy lene

CEP = Celulose w th

DE Blend

ZenCap Lenticular Cloud Filter Capsule Ordering Guide

Operating Conditions: Maximum Operating Pressure: Liquid: 5.5 bar (80psi) at 77°F/25°C Gas: 4.1 bar (60psi) at 77°F/25°C Minimum Burst Pressure: 8.3 bar (120psi) at 77°F/25°C Maximum Forward Differential Pressure: 5 bar (72psi) at 68°F/20°C Maximum Reverse Differential Pressure: 2.1 bar (30psi) at 68°F/20°C

Maximum Operating Temperature: 140°F/60°C Autoclavable & Sanitizable:

Capsules can be autoclaved 3 times at 257°F/125°C for 30 minutes or chemically sanitized in situ using common sanitiz-ing agents or hot water at 194°F/90°C for a limited time (dependent on time and temperature). Capsules must not be in situ steam-sterilized

Specifications

Materials of Construction: Media: Cellulose Media Supports: Polypropylene Shell: Polypropylene Sealing: Thermally-welded Effective Filtration Area : 155-620in2 (1000-4000cm2) Dimensions: 3.54 in (90mm) Available Ratings: 0.15um to 10um Regulatory Compliance: The filters are constructed with polypropyl-

ene resins and filtration media in compli-ance with 21CFR of the US Code of Federal Regulations and USP Class VI Biological Test for Plastic.

b15.8.4 Rev 2011.08

Page 76

Page 78: ZenPure - Q-Test

ZenPure PureFlo Lenticular Cloud Filters

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

b15.8 Rev 2011.08 Page 77

Page 79: ZenPure - Q-Test

ZenCap® Full Size Capsules

ZenPure Z

en

Pu

re

10”-40” Disposable Process Filtration

ZenCap® capsule filter assemblies are ready-to-use, full size filters that offer high flows, increased throughputs, high strength, all with the convenience and cleanliness of a disposable and easy-to-install filter assembly. De-signed for pre-filtration, clarification, and final filtration of medium to large scale batches (100L to 5000L), in the pharmaceutical, biotechnology, food and beverage, medi-cal, chemical, and DI water.

ZenCap® capsule assemblies are available with a wide range of hydrophilic and hydrophobic filter media and pore sizes for liquid, gas, and venting applications. Proc-ess engineers can choose from 12 filtration medias to create any combination of integrated filtration train. These will allow the disposable processing to become truly flexible, clean, and optimal.

They can be built in a T-style or In-line configuration with nine inlet and outlet fitting connections that can be mixed and matched. The filtration shell is an all-polypropylene construction that provides excellent chemical compatibil-ity with low extractables. The shell and supports can also be constructed in nylon, polyethylene or gamma sta-bilized PP shells for additional compatibility. No adhe-sives, binders, or surfactants are used in the manufactur-ing

Specifications

Materials of Construction: Media: Charged Nylon, Depth PP, Polyethylene, PTFE, Glass Fiber, PP Membrane, Cellulose, Nylon, Nylon Screen, PP media, PES, and Polyester Screen Media Supports: Polypropylene, PET, Nylon, or HDPE Shell, Cage, Core, End Caps: Polypropylene, Nylon, or HDPE Sealing: Thermally bonded

Fitting Connections: Nine Fittings - See Ordering Guide for availability. (Custom adaptors available upon request)

Nominal Dimensions: Lengths: 10”, 20”, 30”, 40” Diameter: 3.54” (90mm)

Effective Filtration Area: See Cartridge Datasheet for more information (Dependent on Media) Available Ratings: 0.04um - 200.0um (Dependent on Media) Operating Conditions: Maximum Forward Differential Pressure: Liquid: 5.5 bar (80psi) at 77°F/25°C Gas: 4.1 bar (60psi) at 77°F/25°C Minimum Burst Pressure: 8.3 bar (120psi) at 77°F/25°C Maximum Forward Differential Pressure: 5 bar (72psi) at 68°F/20°C Maximum Reverse Differential Pressure: 3.0 bar (44psi) at 68°F/20°C

Maximum Operating Temperature: PP & Gamma PP: 176°F/80°C HDPE: 140°F/60°C

Regulatory Compliance: The filters are constructed with polypropylene resins and filtration media in compliance with 21CFR Part 177 of the US Code of Federal Regulations and USP Class VI Biological Test for Plastics.

Applications

Clarification Water & Wine

Hard Particle Food & Beverages Cell Removal Pharmaceuticals Chemicals Biologics Inks, Dyes Oils, Waters Cosmetics Diagnostics

Page 78

Page 80: ZenPure - Q-Test

ZenPure ZenCap® Full Size Capsules

ZenPure Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

b15.9 Rev 2011.08

PureFlo ZenCap Filter Capsule Ordering Guide

Specifications (cont.)

Autoclavable & Sanitizable: Capsules can be autoclaved 25 times at 257°F/125°C for 30 minutes or chemically sanitized in situ using common sanitizing agents or hot water at 194°F/90°C for a limited time (dependent on time and tem-perature). Capsules must not be in situ steam-sterilized.

Bacterial Endotoxin: Effluent is non-pyrogenic per USP Bacterial Endotoxin (0.25 EU/ml), determined using Limulus Amebocyte Lysate (LAL) Test.

ZenCap Capsule Series Configuration Length Filter MediaPore size

(Micron)Vents ** Input Fitting Output Fitting Construction Material

1 - 10" CN = Charged Ny lon A = No v ents 3H = 3/8" Hose Barb 3H = 3/8" Hose Barb Blank = Poly propy lene

L I = In-Line 2 - 20" DP = Depth Poly Pro B = 1/2" Sanitary v ent 4H = 1/2" Hose Barb 4H = 1/2" Hose Barb -E = Poly ethy lene

3 - 30" E = Poly ethy lene 4Q = 1/2" Male Quick connect 4Q = 1/2" Male Quick connect

4 - 40" F = PTFE 5H = 9/16" Hose Barb 5H = 9/16" Hose Barb

G = Glass Fiber 6H = 3/4" (19mm) Hose Barb 6H = 3/4" (19mm) Hose Barb -N = Ny lon

M = Poly Pro Membrane 8H = 1" (25mm) Hose Barb 8H = 1" (25mm) Hose Barb

N = Ny lon 4QP = 1/2" Male Quick connect 4QP = 1/2" Male Quick connect Options

NS = Ny lon Screen TC = 1-1/2" Tri-Clamp TC = 1-1/2" Tri-Clamp

P = Poly Pro Media

S = PES Orings

TS = Poly ester Screen

CEP = Cellulose w ith DE* G = Inlet 1/4" Bleed Valv e

H = Outlet 1/4" Bleed Valv e -OE = O-Ring EPDM

-ON = O-Ring Nitrile

-OV = O-Ring Viton

D = 1/2" Sanitary v ent, w ith

upstream 1/4" Bleed Valv e

E = 1/2" Sanitary v ent, w ith

dow n stream 1/4" Bleed Valv e

F = Inlet and Outlet 1/4" Bleed

Valv e Blank = O-Ring Silicon

(Standard)

-ETO = Ethy lene Ox ide

Sterilization

Notes: For -E or -GP options, the standard pleat support will be PET for gamma stability ** 1/4" Drain bleed Valve standard on all T-Line filters Except for option A

90mm Diameter Capsule

for full size cartridges

C = 1/2" Sanitary vent, with

upstream and down stream

1/4" Bleed Valve

Pick From

Pore Size

Table

Note: Option B,C, D &E not for

In-Line

-GP = Gamma Stable

Poly propy leneT = T-Line

Example 1 - ZenCAP L Series Capsule, T-Line, PES 0.45um/0.2um, 20" filter, with all vent and drains, 1.5" Tri-Clamp fittings I/O, would be LT2S045020CTCTC

Example 2 - ZenCAP L Series Capsule, T-Line, GF0.5um/PES 0.2um, 10" filter, with all vent and drains, 1.5" Tri-Clamp fittings I/O, would be LT1G050S020CTCTC

Dimentions in mm

Charged

NylonDepth PP Polyethylene PTFE Glass Fiber PP Membrane Cellulose w/DE Nylon

Nylon

ScreenPP Media PES

Polyester

Screen

005 = 0.05 002 = 0.2 020 = 0.20 010 = 0.1 004 = 0.45 010 = 0.1 015 = 0.15 005 = 0.05 100 = 10 003 = 0.3 004 = 0.04 400 = 40

010 = 0.10 005 = 0.5 100 = 1.0 020 = 0.2 005 = 0.5 020 = 0.2 040 = 0.40 010 = 0.10 200 = 20 006 = 0.6 010 = 0.1 600 = 60

020 = 0.20 010 = 1.0 150 = 1.5 045 = 0.45 010 = 1.0 050 = 0.50 020 = 0.20 400 = 40 010 = 1.0 020 = 0.2 730 = 73

045 = 0.45 015 = 1.5 250 = 2.5 100 = 1.0 030 = 3.0 060 = 0.60 045 = 0.45 600 = 60 030 = 3.0 045= 0.45

065 = 0.65 025 = 2.5 300 = 3.0 050 = 5.0 085 = 0.85 065 = 0.65 10X = 100 050 = 5.0 065 = 0.65

080 = 0.80 045 = 4.5 500 = 5.0 100 = 10.0 150 = 1.50 080 = 0.80 20X = 200 100 = 10.0 080 = 0.8

120 = 1.20 100 = 10 999 = 10.0 200 = 20.0 250 = 2.50 120 = 1.20 200 = 20.0 120 =1.2

200 = 20 300 = 30.0 300 = 3.00 300 = 30.0

400 = 4.00 500 = 50.0

600 = 6.00 700 = 70.0

01X = 10.0**

** - Does not hav e DE

Pore size (Micron)

Page 79

Page 81: ZenPure - Q-Test

PureFlo® Ink Filter Capsules

ZenPure Z

en

Pu

re

Specifications

Materials of Construction: Media: Polypropylene Media Shell, Cage, Core, End Caps: Polypropylene and Black PP Sealing: Thermally bonded Fitting Connections: 1/4” Compression (JACO), No Vent Nominal Dimensions: Lengths: 2.0” (50mm) without fittings Diameter: 3” (77.5mm) Outer Diameter: 3.37” (85.5mm) Effective Filtration Area: 18.6 in2 (120cm2) Available Ratings: 1um - 20.0um (Dependent on Media) Operating Conditions: Maximum Operating Pressure: Liquid: 5.5 bar (80psi) at 77°F/25°C Gas: 4.1 bar (60psi) at 77°F/25°C Maximum Forward Differential Pressure: 4.21 bar (60psi) at 68°F/20°C Maximum Reverse Differential Pressure: 2.1 bar (30 psi) at 68°F/20°C Minimum Burst Pressure: 8.3 bar (120psi) at 77°F/25°C Maximum Operating Temperature: 122°F (50°C)

High Performance Ink Filter

PureFlo® Ink Filter Capsules were designed for filtration of standard and UV sensitive inks. This filter is designed to protect print-heads and commercial printing machines. They come in a standard Polypropylene shell as well as a black PP shell to protect light sensi-tive inks.

The ink capsules have a compact design that can incorporate various polypropylene struc-tures to meet the needs of the different ink applications. We are currently offering five different media pore size options. The poly-propylene construction provides excellent compatibility with a wide-range of inks and their components. No adhesives, binders, or surfactants are used in the manufacturing process. All units are thermally-sealed and flushed, dried and packaged to provide a quality product straight out of the box.

Applications

UV Sensitive Ink Ink

Lab scale testing Chemicals

Vent Filter Small volume

Water Digital Inkjet Printer

Page 80

Page 82: ZenPure - Q-Test

ZenPure PureFlo® Ink Filter Capsules

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

S1 Rev 2011.08

PureFlo Ink Filter Capsule Ordering Guide

PureFlo Capsule

FiltersFilter Media

Pore size

(Micron)Inlet Fitting Outlet Fitting Vent Fitting Option

010 = 1.0P = PolyPro Media 030 = 3.0 2C = 1/4" Compression 2C = 1/4" Compression NV = No Vent

050 = 5.0100 = 10.0 -BLK = Black PP Shell200 = 20.0

IFC = Ink Filter Capsule

Blank = Standard PP Shell

Example - Ink Series,PP Media, 3.0um, 1/4" Compression I/O is IFCP0302C2CNV

Dimensional Drawing

Page 81

Page 83: ZenPure - Q-Test

PureFlo Tank Vent Purifier Capsules

(Removal of VOC and CO2

)

ZenPure Z

en

Pu

re

Specifications

Materials of Construction: Media: Granular Soda Lime and Activated Carbon Fiber Media Supports: Polypropylene Shell, Cage, Core, and End Caps: Polypropylene Fitting Connections: Hose Barb, NPT, Compression Quick Couplings, and Sanitary, Tube Stub. Any inlet/outlet combinations. (Custom adaptors available upon request) No Vent or Drain fittings Nominal Dimensions: Length: 1.5 in (128 mm), Length: 2.5 in (155 mm), Length: 5.0 in (210 mm), Length: 7.5 in (270mm), Length: 10 in (340mm), Diameter: 2.75 in (70 mm) Operating Conditions: Maximum Forward Differential Pressure: Liquid: 5.5 bar (80psi) at 77°F/25°C Gas: 4.1 bar (60psi) at 77°F/25°C Minimum Burst Pressure: 8.3 bar (120psi) at 77°F/25°C Maximum Forward Differential Pressure: 4.21 bar (60psi) at 68°F/20°C Maximum Reverse Differential Pressure: 2.1 bar (30psi) at 68°F/20°C

Maximum Operating Temperature: 140°F/60°C Regulatory Compliance: The filters are constructed with polypropylene resins and filtration media in compliance with 21CFR Part 177 of the US Code of Federal Regulations and USP Class VI Biological Test for Plastic.

Air Purification Filter

PureFlo® Tank Vent Purifier capsules are de-signed to remove volatile organic compounds, hy-drocarbons, chlorine, color, and odors and CO2 from gases with the use of activated fibrous car-bon media and soda lime. Carbon Dioxide is scrubbed out of the gas as it passes through the media matrix in the capsule. It is designed for maximum flow and contaminant removal to elimi-nate potential health hazards. The carbon fiber and soda lime allows for highly efficient contact time and adsorption capacity. Designed with clean, durable polypropylene support structure to provide superior down stream cleanliness. No adhesives, binders, or surfactants are used in the manufacturing process. Each capsule is manu-factured under tight process control to give you a uniform product with every filter. These activated carbon filters are available in a range of lengths and connections to suit your individual purification needs.

Applications Tank Vent Air Filter

Vacuum pump Beverages

Fermentor Pharmaceuticals

Fine Chemicals Biologics

Incubator Wine

Beer Water

Page 82

Page 84: ZenPure - Q-Test

Your Local Distributor:

ZenPure

s2 Rev 2011.08

PureFlo Tank Vent Purifier Capsules

(Removal of VOC and CO2

)

ZenPure

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

PureFlo

Capsule

Filters

Filter MediaCapsule

Length Options

1H = 1/8" Hose barbs 1H = 1/8" Hose barbsSK H = 1.5" 1NF = 1/8" FNPT 1NF = 1/8" FNPT

S = 2.5" 2C = 1/4" Compression 2C = 1/4" CompressionL = 5" 2H = 1/4" to 1/2" Hose barbs 2H = 1/4" to 1/2" Hose barbsE = 7.5" 2HS = 1/4" to 3/8" Hose barbs 2HS = 1/4" to 3/8" Hose barbsK = 10" 2L = Large Female Luer Lock f tting 2L = Large Female Luer Lock f tting

2N = 1/4" MNPT 2N = 1/4" MNPT2NF = 1/4" FNPT 2NF = 1/4" FNPT2Q = 1/4" Male Quick Coupling for Metal latch 2Q = 1/4" Male Quick Coupling for Metal latch2QF = 1/4" Female Quick Coupling with Metal latch 2QF = 1/4" Female Quick Coupling with Metal latch2QFP = 1/4" Female Quick Coupling w th Plast c latch 2QFP = 1/4" Female Quick Coupling with Plast c latch2QP = 1/4" Male Qu ck Coupling for Plastic latch 2QP = 1/4" Male Qu ck Coupling for Plastic latch3C = 3/8" Compression 3C = 3/8" Compression3H = 3/8" Hose Barb 3H = 3/8" Hose Barb3HE = 3/8" Hose Barb Elbow 3HE = 3/8" Hose Barb Elbow3NF = 3/8" FNPT 3NF = 3/8" FNPT4C = 1/2" Compression 4C = 1/2" Compression4H = 1/2" Hose Barb 4H = 1/2" Hose Barb -OE = O-ring EPDM4N = 1/2" MNPT 4N = 1/2" MNPT -ON = O-ring Nitrile4QP = 1/2" Male Qu ck Coupling for Plastic latch 4QP = 1/2" Male Qu ck Coupling for Plastic latch -OV = O-ring V tonMT = 1/2" Tri clamps MT = 1/2" Tri clampsTC = 1-1/2" Tri clamp TC = 1-1/2" Tri clamp4T = 1/2" Tube Stub 4T = 1/2" Tube Stub

-E = Polyethylene Shell and PET media support for Gamma Sterilizat on

Example - 5", Tank Vent capsule, with 1/2" Tri-clamp fittings I/O would be SKCLMTMT

M ale Quick Couplings are molded, Female Quick Coupling with Plastic latch will be threaded on, compatible with CPC (Colder), LinkTech and other compatible couplings.

Input Fitting

-GP = Gamma Stable Polypropylene Shell

Blank = O-ring Silicon (Standard)

O-Ring for Quick

Coupling

Output Fitting

CL = Activated Carbon Fiber w/Lime Soda

70mm Diameter Capsule

PureFlo Tank Vent Capsule Ordering Guide

Page 83

Page 85: ZenPure - Q-Test

PureFlo Shower Capsule Filter

ZenPure Z

en

Pu

re

Specifications

Materials of Construction: Media: PES Media Supports: Polypropylene Shell, Cage, Core, and End Caps: Polypropylene O-Rings: Silicone Fitting Connections: Shower Head, Hose Barb, NPT, Compression, Quick Couplings, Sanitary Any inlet/outlet combinations. (Custom adaptors available upon request) Vent or Drain fittings: M10 Bleed Valve Nominal Dimensions: Length: 1.5 in (128 mm), Length: 2.5 in (155 mm), Length: 5.0 in (210 mm), Diameter: 2.75 in (70 mm) Effective Filtration Area: 1.5 in - 0.77 ft2 (650 cm2) 2.5 in - 1.48 ft2 (1200 cm2) 5.0 in - 2.8 ft2 (2400 cm2) Operating Conditions: Maximum Forward Differential Pressure: Liquid: 5.5 bar (80psi) at 77°F/25°C Minimum Burst Pressure: 8.3 bar (120psi) at 77°F/25°C Maximum Forward Differential Pressure: 5 bar (72psi) at 68°F/20°C Maximum Reverse Differential Pressure: 3 bar (44psi) at 68°F/20°C

Maximum Operating Temperature: 140°F/60°C Regulatory Compliance: The filters are constructed with polypropylene resins and filtration media in compliance with 21CFR Part 177 of the US Code of Federal Regulations and USP Class VI Biological Test for Plastic.

Shower Filter

PureFlo® Shower capsule filters are designed to remove particles and bacteria from municipal water sources. These filters can help improve hospital environments where patients have weak-ened immune systems. This filter can help with pseudomonads, legionella and other pathogens for washing, showering, and bathing applications. The ZenPure PureFlo shower capsule can help meet the strict protocols that hospitals need for high risk patients such as burn or immune defi-ciency victims. This filter provides point of use sterile filtered, potable water directly to the patient. Micro organisms from contaminated water are trapped in the filter. These filters come with a variety of inlet and outlet fittings for easy installation. The PES mem-brane allows for low pressure drops so the patient gets the proper flow. The 0.2 micron membrane used complies with international HIMA guidelines for sterilizing filters, delivering a sterile filtrate af-ter challenges with 107 Brevundimonas diminuta per capsule.

Applications Hospitals Water

Showers Sinks

Bathrooms Wash Stations

ICU Endoscopy

Neonatal Care Unit Birthing Centers

Page 84

Page 86: ZenPure - Q-Test

Your Local Distributor:

ZenPure

S2.5 Rev 2011.08

PureFlo Shower Capsule Filter

ZenPure

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

PureFlo Shower Capsule Ordering Guide

SPECIFICATIONS

Bacterial Retention Complete retention of > 107organisms/cm2 of Bre-vundimonas diminuta in accordance with the cur-rent HIMA challenge methodology (ASTM F838-83). Validation Guide upon request.

Autoclavable & Sanitizable

Recommended to sterilize and verify integrity twice a week to minimize risk of contamination. Capsules can be autoclaved 25 times at 257°F/125°C for 30 minutes or chemically sanitized in situ using com-mon sanitizing agents or hot water at 194°F/90°C for a limited time (dependent on time and tempera-ture). Capsules must not be in situ steam-sterilized.

Water Bubble Point Specification 0.1um : 23psi,0.16 MPA (IPA) 0.2um : 47psi,0.32 MPa

Bacterial Endotoxin Effluent is non-Pyrogenic per USP Bacterial En-dotoxin (0.25 EU/ml), determined using Limulus Amebocyte Lysate (LAL) test.

PureFlo Capsule

Filters

Shower

Filter MediaPore size (Micron)

Internal

Filter

Length

Options

004 = 0.3 PP Media/0.04 PES H = 1 5" 2H = 1/4" Hose Barbs 2H = 1/4" Hose BarbsSKV 010 = 0.6 PP Media/0.1 PES S = 2.5" 2N = 1/4" MNPT 2N = 1/4" MNPT

020 = 1.0 PP Media/0.2um PES L = 5" 2NF = 1/4" FNPT 2NF = 1/4" FNPT2Q = 1/4" Male Quick Coupling for Metal Latch 2Q = 1/4" Male Quick Coupling for Metal Latch2QF = 1/4" Female Quick Coupling with Metal Latch 2QF = 1/4" Female Quick Coupling with Metal Latch2QFP = 1/4" Female Quick Coupling w/Plastic Latch 2QFP = 1/4" Female Quick Coupling w/Plastic Latch2QP = 1/4" Male Quick Coupling for Plastic Latch 2QP = 1/4" Male Quick Coupling for Plastic Latch2V = 1/4" Walther Male Quick Connect (as shown) 3H = 3/8" Hose Barb 3H = 3/8" Hose Barb 3NF = 3/8" FNPT3NF = 3/8" FNPT 4H = 1/2" Hose Barb 4H = 1/2" Hose Barb 4N = 1/2" MNPT4N = 1/2" MNPT 4QP = 1/2" Male Quick Coupling for Plastic latch4QP = 1/2" Male Quick Coupling for Plastic latch MT = 1/2" Tri-clampsMT = 1/2" Tri-clamps TC = 1-1/2" Tri-clampTC = 1-1/2" Tri-clamp TS = Shower Head (as shown)

70mm Diameter Capsule

Blank = Polypro construction

-ETO = Ethylene oxide sterilization

Example - PureFlo Shower Capsule, PP Media/PES , 2.5" internal filter, 1.0/0.2 micron, with 1/4" Walther Coupling Inlet, Shower Head Outlet, would be SKVPS020S2VTS

PS = PP pre filter/PES final

filter

Note Quick Couplings are molded on. Compatible with CPC (Colder) LinkTech and others.

Output FittingInput Fitting

No adhesives, binders, or surfactants are used in the manufacturing process. Each capsule is manufactured under tight process control to give you a uniform product with every filter.

Page 85

Page 87: ZenPure - Q-Test

PureFlo Void Capsules

ZenPure Z

en

Pu

re

High Hold-up Area Capsules

The PureFlo® Void Capsule has been designed for capture of media inside the body of the cap-sule for easy disposal. The filter can be tailored to specific applications and needs. No filter or a smaller than standard is placed in the capsule to allow for a internal void area. This empty space is utilized for media entrapment. All the differ-ent PureFlo Media can be incorporated in this unique design. There are numerous different fitting options for each of the different capsule styles.

The design of the unit can be used as a liquid trap, settling chamber, media capture, or surge suppression. No adhesives, binders, or surfac-tants are used in the construction process.

Applications Bead Capture Particle Capture Surge Suppression Media Hold-up Liquid Trap Settling Chamber DE Capture Filter Pharmaceutical

Specifications Materials of Construction: Media: Any ZenPure PureFlo Media Media Supports: Media Dependent Shell, Cage, Core, and End Caps: Polypropylene, Gamma-stabilized Polypropylene, Polyethylene, Nylon

Fitting Connections: Hose Barb, NPT, Compression Quick Couplings, and Sanitary. Any inlet/outlet combinations. (Custom adaptors available upon request)

Capsule Series: SVL Series: Capsule w/Luer Lock Vent & Drain SVV Series: Capsule w/Bleed Valve Vent & Drain ZenCap Void Series: T-line & I-Line Full Size Capsule

Sterilization: The filters can be sterilized by autoclaving, ETO, and gamma sterilization depending on the construction. Capsules can be autoclaved 25 times at 257°F/125°C for 30 minutes or chemically sanitized in situ using common sanitizing agents or hot water at 194°F/90°C for a limited time (dependent on time and temperature). Capsules must not be in situ steam-sterilized.

Regulatory Compliance: The filters are constructed with polypropylene resins and filtration media in compli-ance with 21CFR Part 177 of the US Code of Federal Regulations and USP Class VI Biological Test for Plastic.

Page 86

Page 88: ZenPure - Q-Test

ZenPure

PureFlo SVV Void Capsule Ordering Guide

SVV Series Capsule

PureFlo® SVV Void capsules can come with a short or no internal filter to allow for greater hold-up capacity. This can be utilized for hard media particle retention. The inlet and outlet ports are available with 18 fittings options, eliminating the need for transition connectors. The SVV series capsule has two adjustable, easy to turn upstream bleed valves with an o-ring seal and hose barb connections allowing for easy process control and/or sampling.

PureFlo SVV Void Capsule

PureFlo Void

CapsuleFilter Media

Pore size

(Micron)

Internal

Filter

Capsule

Length

* = No Filter * = No Filter H= 1.5" 1H = 1/8" Hose Barbs 1H = 1/8" Hose Barbs Shell Material O-Rings

SVV C = Carbon Fiber H = 1.5" S = 2.5" 1NF = 1/8" FNPT 1NF = 1/8" FNPT -OE = O-ring EPDMCN = Charged Nylon S = 2.5" L = 5" 1Q = 1/8" Male Quick Coupling w/Metal Latch 1Q = 1/8" Male Quick Coupling w/Metal Latch -ON = O-ring NitrileDP = Depth PolyPro L = 5" E = 7.5" 1QF = 1/8" Female Quick Coupling with Metal Latch 1QF = 1/8" Female Quick Coupling with Metal Latch -E = Polyethylene shell -OV = O-ring VitonE = Polyethylene E = 7.5" K = 10" 2H = 1/4" Hose Barbs 2H = 1/4" Hose BarbsF = PTFE 2N = 1/4" MNPT 2N = 1/4" MNPTG = Glass Fiber 2NF = 1/4" FNPT 2NF = 1/4" FNPT -NY = Nylon ShellM = PolyPro Mem 2Q = 1/4" Male Quick Coupling for Metal Latch 2Q = 1/4" Male Quick Coupling for Metal LatchN = Nylon 2QF = 1/4" Female Quick Coupling with Metal Latch 2QF = 1/4" Female Quick Coupling with Metal Latch Sterilized

NP = PP Nanofiber 2QFP = 1/4" Female Quick Coupling w/Plastic Latch 2QFP = 1/4" Female Quick Coupling w/Plastic LatchNS = Nylon Screen 2QP = 1/4" Male Quick Coupling for Plastic Latch 2QP = 1/4" Male Quick Coupling for Plastic LatchP = PolyPro Media 3H = 3/8" Hose Barb 3H = 3/8" Hose Barb S = PES 3NF = 3/8" FNPT 3NF = 3/8" FNPT Vent & Drain

TS = Polyester Screen 4H = 1/2" Hose Barb 4H = 1/2" Hose Barb -N= No vent or drain 4N = 1/2" MNPT 4N = 1/2" MNPT Filling Bell

4QP = 1/2" Male Quick Coupling for Plastic latch 4QP = 1/2" Male Quick Coupling for Plastic latch -FB = Filling Bell*MT = 1/2" Tri-clamps MT = 1/2" Tri-clamps -FC = Filling Bell w/Cap*TC = 1-1/2" Tri-clamp TC = 1-1/2" Tri-clamp

70mm Diameter Capsule with Bleed Valve

Blank = No

Filter

Pick From

Pore Size

Table

Blank = O-ring Silicon (Standard)

G(pore Size)= Glass Fiber PreFilter

P(pore Size)= PolyPro Media PreFilter

S(pore Size) = PES PreFilter

Example - PureFlo SVV Void Capsule, Polyester Screen, 30um , 1.5" internal filter, 5" shell, with 1.5" Tri-Clamp fittings I/O, would be SVVTS300HLTCTC

Note: Quick Couplings are molded on. Female Quick Coupling with Plastic latch w ll be threaded on. Compatib e with CPC (Colder), LinkTech and others. * - 2H or 3H w th fil ing bell only

-NO = No vent or drain Outlet fitting

-ETO = Ethylene oxide sterilization

-NI = No vent or drain inlet fitting

Input Fitting Output Fitting Option

Blank = Polypro construction

-GP = Gamma stable polypropylene shell

Prefilter (add before

Filter Media in part#)

S3.0.1 Rev 2011.08

005= 0.05 015 = 1.5 020 = 0.20 010 = 0.1 005 = 0.5 010 = 0.1 005= 0.05 005= 0.5 200 = 20 003 = 0.3 005 = 0.05 300 =30 010 = 0.1 025 = 2.5 100 = 1.0 020 = 0.2 010 = 1.0 020 = 0.2 010 = 0.1 400 = 40 006 = 0.6 010 = 0.1 730 = 73020 = 0.2 045 = 4.5 150 = 1.5 045 = 0.45 030 = 3.0 020 = 0.2 600 = 60 010 = 1.0 020 = 0.2045 = 0.45 100 = 10.0 250 = 2.5 100 = 1.0 050 = 5.0 045 = 0.45 10X = 100 030 = 3.0 045 = 0.45065 = 0.65 200 = 20.0 300 = 3.0 100 = 10.0 065 = 0.65 20X = 200 050 = 5.0 065 = 0.65080 = 0.8 500 = 5.0 200 = 20.0 080 = 0.8 100 = 10.0 080 = 0.8100 = 1.0 999 = 10.0 300 = 30.0 100 = 1.0 200 = 20.0 120 = 1.2

300 = 30.0500 = 50.0700 = 70.0

Polyester

Screen (TS)

Leave pore

size blank

for Carbon

Fiber

PP Nanofiber

(NP)

Nylon

Screen (NS)

PP Media

(P)PES (S)

Carbon

Fiber (C )

Charged

Nylon

(CN

PolyPro

Depth

(D )

Polyethylene

(E)PTFE (F)

Glass

Fiber (G)

PP Membrane

(M)Nylon (N)

Page 87

Page 89: ZenPure - Q-Test

ZenPure

PureFlo SVL Void Filter Capsule Ordering Guide

SVL Void Capsule

PureFlo® SVL Void capsules has 5 capsule sizes to choose from. These units have inter-nal void areas that can be utilized for several purposes. These can range from diatoma-ceous earth collection and filtration to pres-sure surge minimization. The inlet and outlet ports are available with 22 fittings options, eliminating the need for transition connectors. The SVL series capsule has luer lock upstream vent and drain connections, allowing for easy process control. These capsules eliminate the time and expense associated with assembling and cleaning stainless steel housings.

PureFlo

Capsule

Filters

Filter MediaPore size

(Micron)

Internal

Filter

Capsule

Length

* = No Filter * = No FilterH= 1.5" 1H = 1/8" Hose barbs 1H = 1/8" Hose barbs Shell Material O-Rings

SVL C = Carbon Fiber H = 1.5" S = 2.5" 1NF = 1/8" FNPT 1NF = 1/8" FNPT -OE = O-ring EPDMCN = Charged Nylon S = 2.5" L = 5" 2C = 1/4" Compression 2C = 1/4" Compression -ON = O-ring NitrileDP = Depth PolyPro L = 5" E = 7.5" 2H = 1/4" to 1/2" Hose barbs 2H = 1/4" to 1/2" Hose barbs -E = Polyethylene shell -OV = O-ring VitonE = Polyethylene E = 7.5" K = 10" 2HS = 1/4" to 3/8" Hose barbs 2HS = 1/4" to 3/8" Hose barbsF = PTFE 2L = Large Female Luer Lock fitting 2L = Large Female Luer Lock fittingG = Glass Fiber 2N = 1/4" MNPT 2N = 1/4" MNPT -NY = Nylon ShellM = PolyPro Mem 2NF = 1/4" FNPT 2NF = 1/4" FNPTN = Nylon 2Q = 1/4" Male Quick Coupling for Metal latch 2Q = 1/4" Male Quick Coupling for Metal latch Sterilized

NP = PP Nanofiber 2QF = 1/4" Female Quick Coupling w/ Metal latch 2QF = 1/4" Female Quick Coupling w/ Metal latchNS = Nylon Screen 2QFP = 1/4" Female Quick Coupling w/ Plastic latch 2QFP = 1/4" Female Quick Coupling w/ Plastic latchP = PolyPro Media 2QP = 1/4" Male Quick Coupling for Plastic latch 2QP = 1/4" Male Quick Coupling for Plastic latchS = PES 3C = 3/8" Compression 3C = 3/8" Compression Filling Bell

TS = Polyester Screen 3H = 3/8" Hose Barb 3H = 3/8" Hose Barb -FB = Filling Bell*3HE = 3/8" Hose Barb Elbow 3HE = 3/8" Hose Barb Elbow -FC = Filling Bell w/Cap*3NF = 3/8" FNPT 3NF = 3/8" FNPT4C = 1/2" Compression 4C = 1/2" Compression Vent & Drain

4H = 1/2" Hose Barb 4H = 1/2" Hose Barb -N= No vent or drain 4N = 1/2" MNPT 4N = 1/2" MNPT4QP = 1/2" Male Quick Coupling for Plastic latch 4QP = 1/2" Male Quick Coupling for Plastic latchMT = 1/2" Tri clamps MT = 1/2" Tri clampsTC = 1-1/2" Tri clamp TC = 1-1/2" Tri clamp

Prefilter (add before

Filter Media in

G(pore Size)= Glass Fiber PreFilter

P(pore Size)= PolyPro Media PreFilter

S(pore Size) = PES PreFilter

Void Filter

capsule -GP = Gamma stable polypropylene shell

-NO = No vent or drain Outlet fitting

-ETO = Ethylene oxide sterilization

-NI = No vent or drain inlet fitting

Example - 5", Void Filter capsule with a 60um Nylon screen 1.5" internal filter, with 1.5" Tri Clamp Fittings I/O would be SVLNS600HLTCTC

Blank = O-ring Silicon (Standard)

70mm Diameter Capsule

Blank = Polypro construction

M a e Qu ck Coup ings are mo ded, Fema e Qu ck Coup ing with Plastic latch wi l be threaded on, compatible with CPC (Colder), LinkTech and other compatible couplings.

Pick From Pore

Size Table

Blank = No

Filter

Input Fitting Output Fitting Option

PureFlo SVL Void Capsule

S3.0.2 Rev 2011.08

005= 0.05 015 = 1.5 020 = 0.20 010 = 0.1 005 = 0.5 010 = 0.1 005= 0.05 005= 0.5 200 = 20 003 = 0.3 005 = 0.05 300 =30 010 = 0.1 025 = 2.5 100 = 1.0 020 = 0.2 010 = 1.0 020 = 0.2 010 = 0.1 400 = 40 006 = 0.6 010 = 0.1 730 = 73020 = 0.2 045 = 4.5 150 = 1.5 045 = 0.45 030 = 3.0 020 = 0.2 600 = 60 010 = 1.0 020 = 0.2045 = 0.45 100 = 10.0 250 = 2.5 100 = 1.0 050 = 5.0 045 = 0.45 10X = 100 030 = 3.0 045 = 0.45065 = 0.65 200 = 20.0 300 = 3.0 100 = 10.0 065 = 0.65 20X = 200 050 = 5.0 065 = 0.65080 = 0.8 500 = 5.0 200 = 20.0 080 = 0.8 100 = 10.0 080 = 0.8100 = 1.0 999 = 10.0 300 = 30.0 100 = 1.0 200 = 20.0 120 = 1.2

300 = 30.0500 = 50.0700 = 70.0

Polyester

Screen (TS)

Leave pore

size blank

for Carbon

Fiber

PP Nanofiber

(NP)

Nylon

Screen (NS)

PP Media

(P)PES (S)

Carbon

Fiber (C )

Charged

Nylon

(CN

PolyPro

Depth

(D )

Polyethylene

(E)PTFE (F)

Glass

Fiber (G)

PP Membrane

(M)Nylon (N)

Page 88

Page 90: ZenPure - Q-Test

ZenPure

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

ZenCap 10-40 inch Void Capsule

PureFlo® ZenCap Void capsules provides a full size container for filter-ing and capturing settling materials. Sizes range from 10-40 inches in length with options to put up to a 30 inch internal filter or no filter. The inlet and outlet ports are available with 8 fittings options that can be mixed and matched, eliminating the need for transition connectors. The ZenCap void capsule has two adjustable, easy to turn up and down stream bleed values with an o-ring seal and hose barb connec-tions allowing for easy process control. These capsules eliminate the time and expense associated with assembling and cleaning stainless steel housings.

They can be built in a T-style or In-line configuration. The filtration shell is an all polypropylene construction that provides excellent chemical compatibility with low extractables. No adhesives, binders, or surfactants are used in the manufacturing process.

PureFlo ZenCap Void Capsule

ZenCap Void ConfigurationCapsule

LengthInternal Filter Filter Media

Pore size

(Micron)Vents Input Fitting Output Fitting Options

1 = 10" * = No Filter * = No Filter Blank=No Filter A = No vents 3H = 3/8" Hose Barb 3H = 3/8" Hose Barb Shell Material

LV I = In-Line 2 = 20" 5 = 5" CN = Charged Nylon B = 1/2" Sanitary vent 4H = 1/2" Hose Barb 4H = 1/2" Hose Barb Blank = Polypropylene 3 = 30" 1 = 10" DP = Depth PolyPro 4Q = 1/2" Male Quick connect 4Q = 1/2" Male Quick connect -E = Polyethylene 4 = 40" 2 =20" E = Polyethylene 5H = 9/16" Hose Barb 5H = 9/16" Hose Barb

3 = 30" F = PTFE 6H = 3/4" (19mm) Hose Barb 6H = 3/4" (19mm) Hose BarbG = Glass Fiber 8H = 1" (25mm) Hose Barb 8H = 1" (25mm) Hose Barb -NY = Nylon ShellM = PolyPro Membrane 4QP = 1/2" Male Quick connect 4QP = 1/2" Male Quick connectN = Nylon TC = 1-1/2" Tri-Clamp TC = 1-1/2" Tri-ClampNS = Nylon ScreenP = PolyPro MediaS = PESTS = Polyester Screen G = Inlet 1/4" Bleed Valve O-Rings

CEP = Cellulose with DE* H = Outlet 1/4" Bleed

-OE = O-Ring EPDM-ON = O-Ring Nitrile

-OV = O-Ring VitonS(pore Size) = PES PreFilter

For -E or -GP opt ons, the standard pleat support w ll be PET for gamma stability

Blank = O-Ring Silicon (Standard)

Example 1 - ZenCAP Void Series Capsule, T-Line, 10" Capsule Nylon Screen 60um, 5" filter, with all vent and drains, 1.5" Tri-Clamp fittings I/O, would be LVT15NS600CTCTC

* Available in late 2011

Prefilter (add before

Filter Media in part#)

T = T-Line C = 1/2" Sanitary vent, with upstream and down stream 1/4" Bleed Valve 90mm Diameter

Capsule with Bleed Valve

Note: Option B,C, D &E not for In-Line

Pick From Pore

Size Table

D = 1/2" Sanitary vent, with upstream 1/4" Bleed Valve E = 1/2" Sanitary vent, with down stream 1/4" Bleed Valve

G(pore Size)= Glass Fiber PreFilter

P(pore Size)= PolyPro Media PreFilter

-GP = Gamma Stable Polypropylene

F = Inlet and Outlet 1/4" Bleed Valve

ZenCap Void Capsule Ordering Guide

S3.0.3 Rev 2011.08

Charged Nylon

(CN)

Depth PP

(DP)

Polyethylene

(E)PTFE (F)

Glass Fiber

(G)

PP Membrane

(M)

Cellulose w/DE

(CEP)Nylon (N)

Nylon Screen

(NS)PP Media (P) PES (S)

Polyester

Screen (TS)

005 = 0.05 002 = 0.2 020 = 0.20 010 = 0.1 005 = 0.5 010 = 0.1 015 = 0.15 005 = 0 05 100 = 10 003 = 0.3 004 = 0.04 400 = 40010 = 0.10 005 = 0.5 100 = 1.0 020 = 0 2 010 = 1.0 020 = 0 2 040 = 0.40 010 = 0.10 200 = 20 006 = 0.6 010 = 0.1 600 = 60020 = 0.20 010 = 1.0 150 = 1.5 045 = 0.45 030 = 3.0 050 = 0 50 020 = 0 20 400 = 40 010 = 1.0 020 = 0.2 730 = 73045 = 0.45 015 = 1.5 250 = 2.5 100 = 1 0 050 = 5.0 060 = 0 60 045 = 0.45 600 = 60 030 = 3.0 045= 0.45065 = 0.65 025 = 2.5 300 = 3 0 100 = 10.0 085 = 0 85 065 = 0 65 10X = 100 050 = 5.0 065 = 0.65080 = 0.80 045 = 4.5 500 = 5 0 200 = 20.0 150 = 1 50 080 = 0 80 20X = 200 100 = 10.0 080 = 0.8120 = 1.20 100 = 10 999 = 10 0 300 = 30.0 250 = 2 50 120 = 1 20 200 = 20.0 120 =1 2

200 = 20 300 = 3 00 300 = 30.0400 = 4 00 500 = 50.0600 = 6 00 700 = 70.001X = 10 0**

** - Does not have DE

Pore size (Micron)

Page 89

Page 91: ZenPure - Q-Test

PureFlo SKML Multi-Zone Capsule Filter

ZenPure Ze

nPur

e

Specifications

Materials of Construction: Media: Any ZenPure PureFlo Media Media Supports: Media Dependent

Shell, Cage, Core, and End Caps: Polypropylene, Gamma-stabilized, Polypropylene, Polyethylene, Nylon

Fitting Connections: Hose Barb, NPT, Compression Quick Couplings, and Sanitary. Any inlet/outlet combinations. (Custom adaptors available upon request)

Sterilization: The filters can be sterilized by autoclaving, ETO, and gamma sterilization depending on the con-struction. Capsules can be autoclaved 25 times at 257°F/125°C for 30 minutes or chemically sani-tized in situ using common sanitizing agents or hot water at 194°F/90°C for a limited time (dependent on time and temperature). Capsules must not be in situ steam-sterilized.

Regulatory Compliance: The filters are constructed with polypropylene resins and filtration media in compliance with 21CFR Part 177 of the US Code of Federal Regulations and USP Class VI Biological Test for Plastic.

For more specific information please see individual Datasheets for each filter zone.

Multi-Zone Filter

PureFlo® SKML capsule filters are designed to filter product in a two stage process. Two separate filters are permanently joined together to capture agglomerates, large cell fragments or gels and different size particles in separate stages to avoid premature plugging and in-crease filter lifetime. The filters can be tailored to spe-cific applications that have multiple size inclusions and particles. The first filter acts as a pre-filter, protecting the tighter final filter. All the different PureFlo® Media can be incorporated in this unique design. This double filter allows for ease of use, minimizing space and po-tential connection issues. There are numerous different fitting options available for the inlet and outlet. The fittings can me mixed and matched for greater flexibility to minimize or eliminate needed connection adapters. The inlet and outlet ports are available with 23 fitting options.

These capsules eliminate the time and expense of cleaning multiple stainless steel housings or setting up sequential filter capsules aseptically. The capsule shell is an all polypropylene construction that provides excel-lent chemical compatibility with low extractables. No adhesives, binders, or surfactants are used in the manufacturing process. Each capsule is manufactured under tight process control to give you a uniform prod-uct with every filter.

Applications

Fermentor Water

Biologics Pharmaceuticals

Clarification Bio-Bags

Fine Chemicals Food & Beverage

Gel Removal High Loading Processes

Zone 1 Zone 2 Size S Capsule Size H Capsule

Page 90

Page 92: ZenPure - Q-Test

Your Local Distributor:

ZenPure

S4 Rev 2011.08

PureFlo SKML Multi-Zone Capsule Filter

ZenPure

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

PureFlo SKML Capsule Ordering Guide—Pick 1-10 Example of Part number: SKMLLDP010SS020TCTC

PureFlo SKML Capsule, 5” 1st Filter with 1um Depth PP, 2.5” 2nd Filter with 0.2um PES, 1-1/2” Tri-clamp Inlet and Outlet

Cellulose w/DE (CEP)Charged Nylon

(CN)

Depth PP

(DP)

Polyethylene

(E)PTFE (F)

Glass Fiber

(G)

Polypro

Membrane (M)Nylon (N)

Nylon

Screen (NS)

PP Nano

Fiber (NP)PP Media (P) PES (S)

Polyester

Screen (TS)

015 = 0.15 005 = 0.05 002 = 0.2 020 = 0.20 010 = 0.1 005 = 0 5 010 = 0.1 010 = 0.10 100 = 10 005 = 0.5 003 = 0.3 005 = 0.05 200 = 20040 = 0.40 010 = 0.10 005 = 0.5 100 = 1.0 020 = 0.2 010 = 1 0 020 = 0.2 020 = 0 20 200 = 20 006 = 0.6 010 = 0.1 400 = 40050 = 0.50 020 = 0.20 010 = 1.0 150 = 1.5 045 = 0.45 030 = 3 0 045 = 0.45 400 = 40 010 = 1.0 020 = 0.2 600 = 60060 = 0.60 045 = 0.45 015 = 1.5 250 = 2.5 100 = 1.0 050 = 5 0 065 = 0 65 600 = 60 030 = 3.0 045 = 0.45 730 = 73085 = 0.85 065 = 0.65 025 = 2.5 300 = 3.0 100 = 10.0 080 = 0 80 10X = 100 050 = 5.0 065 = 0.65

150 = 1.50 080 = 0.80 045 = 4.5 500 = 5.0 200 = 20.0 120 = 1 20 20X = 200 100 = 10.0 080 = 0.8

250 = 2.50 120 = 1.20 100 = 10 999 = 10.0 300 = 30.0 200 = 20.0 120 = 1.2

300 = 3.00 200 = 20 300 = 30.0400 = 4.00 500 = 50.0600 = 6.00 700 = 70.001X = 10.0** 10X = 100.0** - Does not have DE 15X = 150.0

Pore size Table (in Microns)

1 2 3 4 5 6 7

PureFlo Capsule Filters1st Filter

Length1st Filter Media

1st Filter Pore

size (Micron)

2nd Filter

Length2nd Filter Media

2nd Filter Pore

size (Micron)

H = 1.5" CEP = CEP Media H = 1.5" CEP = CEP Media

SKML = Capsule filter S = 2.5" CN = Charged Nylon S = 2.5" CN = Charged Nylon

Multi-Zone L = 5" DP = Depth PP L = 5" DP = Depth PP

Luer Lock Vent/Drain E = 7.5" E = Polyethylene E = 7.5" E = PolyethyleneK = 10" F = PTFE K = 10" F = PTFE

G = Glass Fiber G = Glass FiberM = PolyPro Mem M = PolyPro MemN = Nylon N = NylonNS = Nylon Screen NS = Nylon ScreenNP = PP Nano Fiber NP = PP Nano FiberP = PolyPro Media P = PolyPro MediaS = PES S = PESTS = Polyester Screen TS = Polyester Screen

Pick From Pore

Size Table

Pick From Pore

Size Table

10

Options

1H = 1/8" Hose barbs 1H = 1/8" Hose barbs Grade

1NF = 1/8" FNPT 1NF = 1/8" FNPT Blank = Standard Grade1QF = 1/8" Female Quick Coupling with Metal latch 1QF = 1/8" Female Quick Coupling with Metal latch -B = Biological Reduction Grade2C = 1/4" Compression 2C = 1/4" Compression -PH = Pharmacuetical Grade 2H = 1/4" to 1/2" Hose barbs 2H = 1/4" to 1/2" Hose barbs2HS = 1/4" to 3/8" Hose barbs 2HS = 1/4" to 3/8" Hose barbs Shell Material

2LF = Large Female Luer Lock fitting 2LF = Large Female Luer Lock fitting Blank = Polypropylene2N = 1/4" MNPT 2N = 1/4" MNPT -GP = Gamma Stablized PP Shell2NF = 1/4" FNPT 2NF = 1/4" FNPT -NY = Nylon Shell2Q = 1/4" Male Quick Coupling for Metal latch 2Q = 1/4" Male Quick Coupling for Metal latch -E = Polyethylene Shell2QF = 1/4" Female Quick Coupling with Metal latch 2QF = 1/4" Female Quick Coupling with Metal latch2QFP = 1/4" Female Quick Coupling with Plastic latch 2QFP = 1/4" Female Quick Coupling with Plastic latch Vent & Drain

2QP = 1/4" Male Quick Coupling for Plastic latch 2QP = 1/4" Male Quick Coupling for Plastic latch -N = No vent or Drain fittings2V = 1/4" Walther Male Quick Connect 3C = 3/8" Compression -NI = No vent or Drain Inlet fitting3C = 3/8" Compression 3H = 3/8" Hose Barb -NO = No vent or Drain Outlet fitting3H = 3/8" Hose Barb 3H-FB = Filling Bell3HE = 3/8" Hose Barb Elbow 3H-FC = Filling bell with

CSterilization

3NF = 3/8" FNPT 3HE = 3/8" Hose Barb Elbow -ETO = Ethylene Oxide Sterilization4C = 1/2" Compression 3NF = 3/8" FNPT4H = 1/2" Hose Barb 4C = 1/2" Compression4N = 1/2" MNPT 4H = 1/2" Hose Barb O-Ring for Quick Coupling

4QP = 1/2" Male Quick Coupling for Plastic latch 4N = 1/2" MNPT Blank = O-ring Silicon (Standard)MT = 1/2" Tri clamp 4QP = 1/2" Male Quick Coupling for Plastic latch -OE = O-ring EPDMTC = 1-1/2" Tri clamp MT = 1/2" Tri clamp -ON = O-ring Nitrile

TC = 1-1/2" Tri clamp -OV = O-ring VitonTS = Shower Head

Inlet Fitting

8 9

Outlet Fitting

Page 91

Page 93: ZenPure - Q-Test

PureFlo SKMV Multi-Zone Capsule Filter

ZenPure Ze

nPur

e

Specifications

Materials of Construction: Media: Any ZenPure PureFlo Media Media Supports: Media Dependent

Shell, Cage, Core, and End Caps: Polypropylene, Gamma-stabilized, Polypropylene, Polyethylene, Nylon

Fitting Connections: Hose Barb, NPT, Compression Quick Couplings, and Sanitary. Vent & Drain: 1/4” Hose Barb Bleed ValvesAny inlet/outlet combinations. (Custom adaptors available upon request)

Sterilization: The filters can be sterilized by autoclaving, ETO, and gamma sterilization depending on the con-struction. Capsules can be autoclaved 25 times at 257°F/125°C for 30 minutes or chemically sani-tized in situ using common sanitizing agents or hot water at 194°F/90°C for a limited time (dependent on time and temperature). Capsules must not be in situ steam-sterilized.

Regulatory Compliance: The filters are constructed with polypropylene resins and filtration media in compliance with 21CFR Part 177 of the US Code of Federal Regulations and USP Class VI Biological Test for Plastic.

For more specific information please see individual datasheets for each filter zone.

Multi-Zone Filter

PureFlo® SKMV capsule filters are designed to filter product in a two stage process. Two separate filters are permanently joined together to capture agglomerates, large cell fragments, gels and different size particles in separate stages to avoid premature plugging and in-crease filter lifetime. The filters can be tailored to spe-cific applications that have multiple size inclusions and particles. The first filter acts as a pre-filter, protecting the tighter final filter. All the different PureFlo® Media can be incorporated in this unique design. This double filter allows for ease of use, minimizing space and po-tential connection issues. There are numerous different fitting options available for the inlet and outlet. The fittings can me mixed and matched for greater flexibility to minimize or eliminate needed connection adapters. The inlet and outlet ports are available with 20 fitting options. The vent and drain are convenient multi-turn bleed valves to allow for sampling or evacuation of air.

These capsules eliminate the time and expense of cleaning multiple stainless steel housings or setting up sequential filter capsules aseptically. The capsule shell is an all polypropylene construction that provides excel-lent chemical compatibility with low extractables. No adhesives, binders, or surfactants are used in the manufacturing process. Each capsule is manufactured under tight process control to give you a uniform prod-uct with every filter.

Applications

Fermentor Water

Biologics Pharmaceuticals

Clarification Bio-Bags

Fine Chemicals Food & Beverage

Gel Removal High Loading Processes

Zone 2 Zone 1 Size H Capsule Size L Capsule

FLOW

Page 92

Page 94: ZenPure - Q-Test

Your Local Distributor:

ZenPure

S5 Rev 2011.08

PureFlo SKMV Multi-Zone Capsule Filter

ZenPure

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

PureFlo SKMV Capsule Ordering Guide—Pick 1-10 Example of Part number: SKMVLDP010SS020TCTC

PureFlo SKMV Capsule, 5” 1st Filter with 1um Depth PP, 2.5” 2nd Filter with 0.2um PES, 1-1/2” Tri-clamp Inlet and Outlet

Cellulose w/DE (CEP)Charged Nylon

(CN)

Depth PP

(DP)

Polyethylene

(E)PTFE (F)

Glass Fiber

(G)

Polypro

Membrane (M)Nylon (N)

Nylon

Screen (NS)

PP Nano

Fiber (NP)PP Media (P) PES (S)

Polyester

Screen (TS)

015 = 0.15 005 = 0.05 002 = 0.2 020 = 0.20 010 = 0.1 005 = 0 5 010 = 0.1 010 = 0.10 100 = 10 005 = 0.5 003 = 0.3 005 = 0.05 200 = 20040 = 0.40 010 = 0.10 005 = 0.5 100 = 1.0 020 = 0.2 010 = 1 0 020 = 0.2 020 = 0 20 200 = 20 006 = 0.6 010 = 0.1 400 = 40050 = 0.50 020 = 0.20 010 = 1.0 150 = 1.5 045 = 0.45 030 = 3 0 045 = 0.45 400 = 40 010 = 1.0 020 = 0.2 600 = 60060 = 0.60 045 = 0.45 015 = 1.5 250 = 2.5 100 = 1.0 050 = 5 0 065 = 0 65 600 = 60 030 = 3.0 045 = 0.45 730 = 73085 = 0.85 065 = 0.65 025 = 2.5 300 = 3.0 100 = 10.0 080 = 0 80 10X = 100 050 = 5.0 065 = 0.65

150 = 1.50 080 = 0.80 045 = 4.5 500 = 5.0 200 = 20.0 120 = 1 20 20X = 200 100 = 10.0 080 = 0.8

250 = 2.50 120 = 1.20 100 = 10 999 = 10.0 300 = 30.0 200 = 20.0 120 = 1.2

300 = 3.00 200 = 20 300 = 30.0400 = 4.00 500 = 50.0600 = 6.00 700 = 70.001X = 10.0** 10X = 100.0** - Does not have DE 15X = 150.0

Pore size Table (in Microns)

1 2 3 4 5 6 7

PureFlo Capsule

Filters

1st Filter

Length1st Filter Media

1st Filter Pore

size (Micron)

2nd Filter

Length2nd Filter Media

2nd Filter Pore

size (Micron)

H = 1.5" CEP = CEP Media H = 1.5" CEP = CEP Media

SKMV = Capsule filter S = 2.5" CN = Charged Nylon S = 2.5" CN = Charged Nylon

Multi-Zone L = 5" DP = Depth PP L = 5" DP = Depth PP

Bleed Valve Vents E = 7.5" E = Polyethylene E = 7.5" E = PolyethyleneK = 10" F = PTFE K = 10" F = PTFE

G = Glass Fiber G = Glass FiberM = PolyPro Mem M = PolyPro MemN = Nylon N = NylonNS = Nylon Screen NS = Nylon ScreenNP = PP Nano Fiber NP = PP Nano FiberP = PolyPro Media P = PolyPro MediaS = PES S = PESTS = Polyester Screen TS = Polyester Screen

Pick From Pore

Size Table

Pick From Pore

Size Table

8 9 10

Inlet Fitting Outlet Fitting Options

1H = 1/8" Hose barbs 1H = 1/8" Hose barbs Grade

1NF = 1/8" FNPT 1NF = 1/8" FNPT Blank = Standard Grade1Q = 1/8" Male Quick Coupling for Metal latch 1Q = 1/8" Male Quick Coupling for Metal latch -B = Biological Reduction Grade1QF = 1/8" Female Quick Coupling with Metal latch 2C = 1/4" Compression -PH = Pharmacuetical Grade 2C = 1/4" Compression 2H = 1/4" to 1/2" Hose barbs2H = 1/4" to 1/2" Hose barbs 2N = 1/4" MNPT Shell Material

2N = 1/4" MNPT 2NF = 1/4" FNPT Blank = Polypropylene2NF = 1/4" FNPT 2Q = 1/4" Male Quick Coupling for Metal latch -GP = Gamma Stablized PP Shell2Q = 1/4" Male Quick Coupling for Metal latch 2QF = 1/4" Female Quick Coupling with Metal latch -NY = Nylon Shell2QF = 1/4" Female Quick Coupling with Metal latch 2QFP = 1/4" Female Quick Coupling with Plastic latch -E = Polyethylene Shell2QFP = 1/4" Female Quick Coupling with Plastic latch 2QP = 1/4" Male Quick Coupling for Plastic latch2QP = 1/4" Male Quick Coupling for Plastic latch 3H = 3/8" Hose Barb Vent & Drain

2V = 1/4" Walther Male Quick Connect 3H-FB = Filling Bell -N = No vent or Drain fittings3H = 3/8" Hose Barb 3H-FC = Filling bell with Cap -NI = No vent or Drain inlet fitting3NF = 3/8" FNPT 3NF = 3/8" FNPT -NO = No vent or Drain Outlet fitting4H = 1/2" Hose Barb 4H = 1/2" Hose Barb 4N = 1/2" MNPT 4N = 1/2" MNPT Sterilization

4QP = 1/2" Male Quick Coupling for Plastic latch 4QP = 1/2" Male Quick Coupling for Plastic latch -ETO = Ethylene Oxide SterilizationMT = 1/2" Tri clamp MT = 1/2" Tri clampTC = 1-1/2" Tri clamp TC = 1-1/2" Tri clamp O-Ring for Quick Coupling

TS = Shower Head Blank = O-ring Silicon (Standard)-OE = O-ring EPDM-ON = O-ring Nitrile-OV = O-ring Viton

Page 93

Page 95: ZenPure - Q-Test

PureFlo® EDF Capsule

ZenPure Z

enP

ure

Specifications Materials of Construction: Media: Polypropylene Media, PTFE, Nylon Screen, PES, Polyester Screen Shell, Cage, Core, End Caps: Polypropylene , PE, Nylon Sealing: Thermally bonded Fitting Connections: Male Quick Connect, Hose Barb Nominal Dimensions: Lengths: Long - 190mm (7.48”) , Short - 127mm (5”) Dimensions : 21mm (0.82”) x 29mm (1.14”) Effective Filtration Area: 4 in2 (26cm2) Available Ratings: 0.1um - 200.0um (Dependent on Media) Operating Conditions: Maximum Operating Pressure: Liquid: 5.5 bar (80psi) at 77°F/25°C Maximum Forward Differential Pressure: 4.21 bar (60psi) at 68°F/20°C Maximum Reverse Differential Pressure: 2.1 bar (30 psi) at 68°F/20°C Minimum Burst Pressure: 8.3 bar (120psi) at 77°F/25°C Maximum Operating Temperature: 176°F (80°C) Autoclave Cycles: The filters can be sterilized by autoclaving for 10 cycles at 257°F/125°C for 30 minutes, except for PE membrane. Capsules must not be in situ steam- sterilized.

Endoscope Disinfectant Filter

PureFlo® Endoscope Disinfectant Filter is designed for quick and easy connection to endoscope wash machines’ disinfectant and air lines.

The polypropylene construction provides excellent compatibility with a wide-range of disinfectants. No adhesives, binders, or surfactants are used in the manufacturing process. All units are thermally-sealed and flushed, dried and packaged to provide a quality product straight out of the box.

Applications

Endoscopes Chemicals

Lab scale testing Water

Scale up Processing Clarification Replacement for #MF-01-0011 is ZenPure #EDFNS200L2Q2QP

Replacement for #MF01-0028 is ZenPure #EDFF020S2QP2QP

Page 94

Page 96: ZenPure - Q-Test

ZenPure PureFlo® EDF Capsule

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company. Copyright 2003-2012 ZenPure or an affiliated company. All rights reserved.

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

S6 Rev 2011.08

PureFlo Capsule Filters

Filter Media Pore size (Micron) Length Options

EDF F = PTFE S = Short 1Q = 1/8" Male Quick Coupling for Metal latch 1Q = 1/8" Male Quick Coupling for Metal latch GradePureFlo NS = Nylon Screen L = Long 1QP = 1/8" Male Quick Coupling for Plastic latch 1QP = 1/8" Male Quick Coupling for Plastic latch Blank = Standard Grade

P = PP Media 2H = 1/4" to 1/2" Hose barbs 2H = 1/4" to 1/2" Hose barbs Shell MaterialS = PES 2Q = 1/4" Male Quick Coupling for Metal latch 2Q = 1/4" Male Quick Coupling for Metal latch Blank = PolypropyleneTS = Polyester Screen 2QP = 1/4" Male Quick Coupling for Plastic latch 2QP = 1/4" Male Quick Coupling for Plastic latch -GP = Gamma Stablized PP Shell

-NY = Nylon Shell-E = Polyethylene Shell

Sterilization-ETO = Ethylene Oxide Sterilization

O-Ring for Quick CouplingBlank = O-ring Silicon (Standard)-OE = O-ring EPDM-ON = O-ring Nitrile-OV = O-ring Viton

Input Fitting Output Fitting

Pick From Pore Size

Table

Example - Block Capsule, Nylon Screen, 20 micron,Long version, 1/4" Male Quick Connect for Metal Latch Inlet, 1/4" Male Quick Connect for Plastic latch would be EDFNS200L2Q2QPQuick Couplings are molded, compatible with CPC (Colder), LinkTech and others.

Endoscope Disinfectant

Filter Capsule

PureFlo Endo Disinfectant Filter Ordering Guide

12

29

190

89

127

89

(1.14”) (0

82”)

(7.48”)

(3.5”)

(3 5”)

(5”)

Dimensions in mm (inch)

2QP Fittings

PTFE (F) Nylon Screen (NS) PP Media (P) PES (S) Polyester Screen (TS)

010 = 0.1 100 = 10 003 = 0.3 004 = 0.04 200 = 20020 = 0.2 200 = 20 006 = 0.6 010 = 0.1 400 = 40045 = 0.45 400 = 40 010 = 1.0 020 = 0.2 600 = 60100 = 1.0 600 = 60 030 = 3.0 045= 0.45 730 = 73300 = 3.0 10X = 100 050 = 5.0 065 = 0.65500 = 5.0 20X = 200 100 = 10.0 080 = 0.8999 = 10.0 200 = 20.0 120 =1.2

300 = 30.0500 = 50.0700 = 70.0

Pore size (Micron)

Page 95

Page 97: ZenPure - Q-Test

PureFlo® Junior Cartridges

Compact Filtration

ZenPure Z

en

Pu

re

Multi-Use Junior Cartridge

PureFlo® Junior cartridges are ready-to-use filters that offer high flows, increased throughputs, high strength, all with the convenience in a small package. Designed for small applications in pharmaceutical, biotechnology, food and beverage, medical, chemical, and DI water.

PureFlo® Junior cartridge are available with a wide range of hydrophilic and hydrophobic filter medias and pore sizes for liquid, gas, and venting applications. Process engineers can choose from 11 filtration medias to meet their needs.

They can be built with several configurations, and used without a housing. The cage, core, and fitting are all-polypropylene construction that provides excellent chemical compatibility with low extractables. The sup-ports can also be constructed in nylon, polyethylene, or gamma stabilized PP for additional compatibility. The filter is manufactured by thermal bonding. No adhesives, binders, or surfactants are used in the manufacturing process.

Applications

Clarification Water & Wine

Hard Particle Food & Beverages Vacuum Pump Pharmaceuticals Chemicals Biologics Inks, Dyes Tank Vent Aerator Vent

Specification

Materials of Construction: Media: Charged Nylon, Depth PP, Polyethylene, PTFE, Glass Fiber, PP Membrane, Nylon, Nylon Screen, PP media, PES, and Polyester Screen Media Supports: Polypropylene, Polyester, Nylon, or HDPE Shell, Cage, Core, End Caps: Polypropylene, Nylon, or HDPE Sealing: Thermally bonded Fitting Connections: 11 Fittings - See Ordering Guide for availability. (Custom adaptors available upon request) Nominal Dimensions: Lengths: 1.5” (35.5mm) without fittings, 2.5” (65mm) without fittings Diameter: 1.14” (29mm) Effective Filtration Area: 260cm2 for single layer membrane, 230cm2 for double layer membrane 200cm2 for Depth and Screen Media Available Ratings: 0.04um - 200.0um (Dependent on Media) Operating Conditions: Maximum Operating pressure: 5 bar (73psi) at 25°C Maximum Operating Temperature: 80° C Regulatory Compliance: The filters are constructed with polypropylene resins and filtration media in compliance with 21CFR Part 177 of the US Code of Federal Regulations and USP Class VI Biological Test for Plastics.

Page 96

Page 98: ZenPure - Q-Test

ZenPure PureFlo® Junior Cartridges

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

B15.95 Rev 2011.07.2

PureFlo® Junior Filter Cartridge Ordering Guide

Charged

Nylon (CN)

Depth PP

(DP)

Polyethylene

(E)PTFE (F)

Glass

Fiber (G)

Polypro

Membrane

(M)

Nylon (N)

Nylon

Screen

(NS)

Polypro

Media (P)

Philic

PTFE

(HF)

PES (S)

005= 0.05 002 = 0.2 020 = 0.20 010 = 0.1 004 = 0.45 010 = 0.1 005= 0.05 100 = 10 003 = 0.3 Request 005 = 0.05010 = 0.10 005 = 0.5 100 = 1.0 020 = 0.2 005 = 0.5 020 = 0.2 010 = 0.10 200 = 20 006 = 0.6 010 = 0.1020 = 0.20 010 = 1.0 150 = 1.5 045 = 0.45 010 = 1.0 020 = 0.20 400 = 40 010 = 1.0 020 = 0.2045 = 0.45 015 = 1.5 250 = 2.5 100 = 1.0 030 = 3.0 045 = 0.45 600 = 60 030 = 3.0 045 = 0.45065 = 0.65 025 = 2.5 300 = 3.0 050 = 5.0 065 = 0.65 10X = 100 050 = 5.0 065 = 0.65080 = 0.80 045 = 4.5 500 = 5.0 100 = 10.0 080 = 0.80 20X = 200 100 = 10.0 080 = 0.8120 = 1.20 100 = 10.0 999 = 10.0 200 = 20.0 120 = 1.20 200 = 20.0 120 = 1.2

200 = 20.0 300 = 30.0 005 = 0.5 300 = 30.0500 = 50.0700 = 70.0

Polypro

Nano Fiber

(NP)

Pore size (Micron)

PureFlo Mini

Cartridge Filters

PreFilter Filter

Media

PreFilter Pore

Size (Micron)Final Filter Media

Pore Size

(Micron)Length End Modification

CN = Charged Nylon H = 1.5" 0H = 1/16-3/32" Hose Barb Shell Material O-Rings

DP = Depth PolyPro S = 2.5" 1C = 1/8" Compression

CN = Charged Nylon E = Polyethylene 1H = 1/8-3/16" Hose Barb

E = Polyethylene F = PTFE 1N = 1/8" NPTM -OE = O-ring EPDM

F = PTFE G = Glass Fiber -ON = O-ring Nitrile

G = Glass Fiber M = PolyPro Mem -OV = O-ring Viton

M = PolyPro Mem N = Nylon 2H = 3/16-1/4" Hose Barb Sterilized

N = Nylon NP = PP Nano Fiber 2UF = 1/4-28 thread Female

NP = PP Nano Fiber NS = Nylon Screen 3H = 1/4-3/8" Hose Barb

P = PolyPro Media P = PolyPro Media LF = Luer Lock Female

HF = Hydrophilic PTFE HF = Hydrophilic PTFE LM = Luer Lock Male

S = PES S = PES MT = 1/2" Tri Clamp

Blank = Polypro construction

-E = Polyethylene construction

-GP = Gamma stable polypropylene construction

Blank = O-ring Silicon (Standard)

Options

Example - MJ Series, PTFE, 1.0um, no prefilter, 1/4" Hose Barb I/O is MJF100H2H

Quick Couplings are molded, compatible with CPC (Colder), LinkTech and others.

Blank = No Pre filter

1Q = 1/8" Male Quick Coupling

-ETO = Ethylene oxide sterilization

-NY = Nylon construction

Blank = No Pre filter

Pick From Pore

Size Table

MJ = Cartridge Filter, PP parts standard Grade

Pick From

Pore Size

Table

Blank = Same media as Prefilter

MJ-2UF 1/4"-28 Female Thread

Luer ock FemaleMJ-LF

78

82

77.5

1/4"-3/8" Hose Barb

1/8" MNPTMJ-1N

MJ-3H

71

1/8" Male Quick Coupling

77.5

MJ-1Q

Code name Outlet FittingS Size(2.5")

A

MJ-1C

MJ-0H

MJ-1H

MJ-2H

1/8" Compression

1/16"-3/32" Hose Barb

1/8"-3/16" Hose Barb

3/16"-1/4" Hose Barb

74.5

77.5

77.5

78.5

H Size(1.5")

29

29

29

29

29

29

29

29

29

35.5

35.5

35.5

35.5

35.5

35.5

35.5

35.5

35.5

48.5

48.5

53

42

45.5

48.5

49

49.5

48.5

64.5

64.5

64.5

64.5

64.5

64.5

64.5

64.5

64.5

B CCBA

29

29

29

29

29

29

29

29

29

50 35.5MJ-MT 7929 64.5 291/2" Tri clamps

B

A

C

MJ-0H

MJ-LF

MJ-1H

MJ-1Q

MJ-2H

MJ-2UF MJ-MT

MJ-3H MJ-1C

MJ-1N

17

56

29

Length S

Length H

Page 97

Page 99: ZenPure - Q-Test

PureFlo® Polypropylene Membrane Filter Cartridges

ZenPure Z

en

Pu

re

PureFlo® polypropylene membrane filter cartridges are highly

retentive and naturally hydrophobic filters. Polypropylene

membrane is a reliable choice for the purification of

aggressive chemicals, compressed gases, and vent

applications. The all-polypropylene construction is an

excellent economic alternative to more expensive

fluoropolymer-based cartridges

No adhesives, binders, or surfactants are used in the

manufacturing process. Furthermore, the all-polypropylene

construction provides excellent thermal and chemical

compatibility with low and high pH chemicals.

PureFlo polypropylene membrane filter cartridges are absolute

rated to ensure consistent filter performance each and every

time out of the package. All filter cartridges are 100% integrity

tested to ensure filter performance.

Materials of Construction

Media: Polypropylene Membrane (hydrophobic)

Media Supports: Polypropylene

Cage, Core, End Caps: Polypropylene

O-Rings: Silicone, EPDM, Fluoro-elastomer,

Buna N, TES, TEV

Dimensions (nominal)

Lengths: 5 in. (13 cm), 10 in. (25 cm), 20 in.

(50 cm), 30 in. (76 cm), 40 in. (102 cm)

Diameter: 2.75 in. (7 cm)

Effective Filtration Area

0.65 m2 (7 ft2) per 10" cartridge element

Operating Conditions

Maximum Forward Differential Pressure:

5.0 bar (72.5 psid) at 20° C

2.0 bar (29 psid) at 80° C

Maximum Reverse Differential Pressure:

3.0 bar (43.5 psid) at 20° C

1.0 bar (14.5 psid) at 80° C

Maximum Operating Temperature: 80° C

Applications

Acids Ink

Bases Parts Cleaning

Solvents Pharmaceuticals

Fine Chemicals Biologics

Plating Solutions Vent

Features Benefits

■ Polypropylene Pleated Membrane Media

(Absolute Rated)

■ Consistent and reproducible particulate removal

■ High flow rates and low pressure drops

■ Superior filter lifetime and process throughputs

■ 100% Polypropylene Construction ■ Provides excellent compatibility with a wide range of chemicals

such as acids, bases, and solvents

■ No media migration into the process fluid

■ Low Filter Extractables ■ No adhesives, binders, or surfactants are used during manufacturing

resulting in superior downstream cleanliness

■ All cartridges are rinsed with high-purity water to reduce

extractables and downtime

Page 98

Page 100: ZenPure - Q-Test

ZenPure PureFlo® Polypropylene Membrane Filter Cartridges

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

B16 Rev 2011.08

PureFlo Polypropylene Membrane Filter Cartridge Ordering Guide

0

2

4

6

8

10

0

0.08

0.16

0.24

0.32

0.4

0.48

0.56

0.64

0 5 10 15

0 8 16 24 32 40 48 56

PureFlo PolyPro Membrane Cartridge

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

0.1

0.2

Polypropylene

Membrane Filter

Cartridges

Removal Rating

(micron)Connections Length

O-Ring / Gasket

Materials

Package

QuantityInserts

10 = 0.10 0 = 222 O-Ring Flat 1 = 10" E = EPDM 1 = 1 per pack Blank = Standard

MCP = Poly propy lene 20 = 0.20 5 = 222 O-Ring Spear 2 = 20" N = Buna N

Membrane 6 = 226 O-Ring Flat 3 = 30" S = Silicone

7 = 226 O-Ring Spear 4 = 40" V = Fluro-Elastomers

F = DOE Flat Gasket 5 = 5" T = TEV*

S = SOE Flat Gasket 9 = 9.75" U = TES*

Z = SOE Internal 213

O-ring Flat **

- 5 = Stainless

Steel Insert

* - not av ailable in Code Z ** - only av ailable in 5", 10" and 20"

Ex ample - PP Membrane filter, 10", 0.2 micron cartridge, w ith 2-222 Silicone o-ring, Flat end cap, and no insert w ould be MCP2001S1

Regulatory Compliance

Manufactured from materials that conform to the require-

ments of 21CFR Part 177 of the U.S. Code of Federal Regula-

tions and USP Class VI Biological Test for Plastics.

Sterilization & Autoclaving

The filters can be sterilized by autoclaving for up to 25 cycles

at 257°F/125°C. The filters can also be sterilized by steam-in-

place procedure up to 5 cycles at 275°F/135°C for 30 minutes

at less than 0.3 bar differential pressure. The filters can also

sanitized by hot water or common chemicals that are compati-

ble with filter components.

Page 99

Page 101: ZenPure - Q-Test

PureFlo® Polypro Filter Cartridges

ZenPure Z

en

Pu

re

PureFlo® polypropylene filter cartridges are highly retentive,

graded porosity polypropylene media filters that have been

specially designed for clarification and pre-filtration

applications. The graded porosity design removes particles in

sequence by size – larger particles by the more open outer

layers and smaller particles by the tighter inner layers. The

outer layers act as a pre-filter while the inner layers provide

the absolute rating at the specified pore size. This efficiently

spreads the contaminants throughout the media matrix

resulting in superior contaminant holding capacity, lifetime,

and pressure drop as compared to other media cartridges.

No adhesives, binders, or surfactants are used in the

manufacturing process. The non-woven media does not allow

migration into the process fluid, thereby reducing the potential

for extractables and downtime. Furthermore, the all-

polypropylene construction provides excellent thermal and

chemical compatibility with low and high pH chemicals.

PureFlo polypropylene filter cartridges ensure consistent filter

performance each and every time out of the package.

Materials of Construction

Media: Non-Woven Polypropylene

Media Supports: Polypropylene

Cage, Core, End Caps: Polypropylene

O-Rings: Silicone, EPDM, Viton, Buna N, TES, TEV

Dimensions (nominal)

Lengths: 5 in. (13 cm), 10 in. (25 cm), 20 in. (50

cm), 30 in. (76 cm), 40 in. (102 cm)

Diameter: 2.75 in. (7 cm)

Effective Filtration Area

0.6 m2 (6.4 ft2) per 10" cartridge element

Operating Conditions

Maximum Forward Differential Pressure:

5.0 bar (72.5 psid) at 20° C

2.0 bar (29 psid) at 80° C

Maximum Reverse Differential Pressure:

3.0 bar (43.5 psid) at 20 °C

1.0 bar (14.5 psid) at 80° C

Maximum Operating Temperature: 80° C

Applications

Acids Ink Jets

Bases Electronics

Solvents Pharmaceuticals

Fine Chemicals Biologics

Plating Solutions Dyes

Parts Cleaning Lacquers

Features Benefits

■ Graded Porosity Pleated Polypro Media

■ Media matrix removes particles in sequence by size – larger

particles by the more open outer layers and smaller particles by the

tighter inner layers

■ High flow rates and low pressure drops

■ Superior filter lifetime and process throughputs

■ 100% Polypropylene Construction ■ Provides excellent compatibility with a wide-range of chemicals

such as acids, bases and solvents

■ No media migration into the process fluid

■ Low Filter Extractables ■ No adhesives, binders, or surfactants are used during manufacturing

resulting in superior downstream cleanliness

■ All cartridges are rinsed with high-purity water to reduce

extractables and downtime

■ High Performance Filtration ■ Consistent and reproducible particulate removal

Page 100

Page 102: ZenPure - Q-Test

ZenPure PureFlo® Polypro Filter Cartridges

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated com-

pany

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

B17 Rev 2011.08

PureFlo Polypro Filter Cartridge Ordering Guide

0

5

10

15

0

0.2

0.4

0.6

0.8

1

0 5 10 15 20

0 10 20 30 40 50 60 70

PureFlo PolyPro Cartridge

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

3.0

7.0, 10

0.3

0.6

1.0

5.0

30, 50, 70

PureFlo Polypro

Media

Pore Size

(micron)

Connections

Length

Gasket / O-

Ring Materials

Package

Quantity

Inserts

NCP

03 = 0.3 06 = 0.6 10 = 1.0 30 = 3.0 50 = 5.0 70 = 7.0 1X = 10 2X = 20 3X = 30 5X = 50 7X = 70 10X = 100 15X = 150

0 = 222 O-Ring Flat 5 = 222 O-Ring Spear 6 = 226 O-Ring Flat 7 = 226 O-Ring Spear F = DOE Flat Gasket S = SOE Flat Gasket Z = SOE Internal 213

O-Ring Flat **

1 = 10” 2 = 20” 3 = 30” 4 = 40” 5 = 5” 9 = 9.75”

E = EPDM N = Buna N S = Silicone V = Viton T = TEV * U = TES *

1 = 1 per pack 6 = 6 per pack

Blank = Standard -5 = Stainless Steel Insert

Example – 10”, 1.0 micron, with 2-222 EPDM O-Rings/Spear Cap and no insert would be NCP1051E1

* - not available in Code Z **- only available in 5", 10", and 20"

Regulatory Compliance

Manufactured from materials that conform to the requirements of 21CFR Part 177 of the U.S. Code of Federal Regula-

tions and USP Class VI Biological Test for Plastics.

Sterilization & Autoclaving

The filters can be sterilized by autoclaving for up to 25 cycles at 257°F/125°C. The filters can also be sterilized by steam-in-

place procedure up to 5 cycles at 275°F/135°C for 30 minutes at less than 0.3 bar differential pressure. The filters can also

sanitized by hot water or common chemicals that are compatible with filter components.

Page 101

Page 103: ZenPure - Q-Test

PureFlo® Depth Pleated Polypro Filter Cartridges

(Thick pleated depth media)

ZenPure Ze

nPur

e

High Bio-Burden Efficient Filtration

PureFlo® pleated depth cartridge filters are designed for large scale filtration and clarification applications in the pharmaceutical, biotechnol-ogy, food and beverage, medical, chemical, wa-ter, and power generation industries worldwide. This family of products is particularly suitable for the fluids that contain high bio-burdens or sus-pended solids.

Highly retentive graded porosity design removes particles in sequence by size – larger particles by the more open outer layers and smaller particles by the tighter inner layers. The outer layers act as a pre-filter while the inner layers provide the absolute rating at the specified pore size. This efficiently spreads the contaminants throughout the media matrix resulting in superior contami-nant holding capacity, lifetime, and pressure drop as compared to other media cartridges.

Applications Clarification Ink

Bio-Burden Beverages

Yeast Removal Pharmaceuticals

Fine Chemicals Biologics

Plating Solutions Wine

Beer Water

pleated depth cartridge filters are

Specifications

Materials of Construction: Media: Non-Woven Polypropylene Media Supports: Polypropylene Cage, Core, End Caps: Polypropylene O-Rings: Silicone, EPDM, Fluoro-Elastomer, Buna N, TES, TEV

Fitting Connections: See ordering guide for the availability Custom adaptors available upon request

Nominal Dimensions: Lengths: 5 in. (13 cm), 10 in. (25 cm), 20 in. (50 cm), 30 in. (76cm), 40 in. (102cm)

Diameter: 2.75 in. (7 cm)

Available Ratings: 0.2um, 0.5um, 1.0um, 1.5um, 2.5um, 4.5um, 10um, and 20um

Operating Conditions: Maximum Forward Differential Pressure: 5.0 bar (72.5 psid) at 20° C, 2.0 bar (29 psid) at 80° C

Maximum Reverse Differential Pressure: 3.0 bar (43.5 psid) at 20° C, 1.0 bar (14.5 psid) at 80 °C

Maximum Operating Temperature: 80° C

Regulatory Compliance: The filters are constructed with polypropylene resins and filtration media in compliance with 21CFR Part 177 of the US Code of Fed- eral Regulations and USP Class VI Biological Test for Plastic.

Page 102

Page 104: ZenPure - Q-Test

ZenPure PureFlo® Depth Pleated Polypro Filter Cartridges

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

B17.5 Rev 2011.08

0

0.5

1

1.5

2

0

0.02

0.04

0.06

0.08

0.1

0.12

0 2 4 6 8 10

0 5 10 15 20 25 30 35

PureFlo Depth Pleated PolyPro Cartridge

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

10" Cartridge

20

1.5

2.5

4.510

1.0

0.5

PureFlo Depth Pleated Polypro Filter Cartridge Ordering Guide

PureFlo

Polypropylene Filter

Cartridges

Removal Rating End Modifications LengthO-Ring / Gasket

MaterialsPackage Qty Inserts

02 = 0.2 micron 0 = 222 O-Ring Flat 1 - 10" E = EPDM 1 = 1pc/ pack Blank = Standard

05 = 0.5 micron 5 = 222 O-Ring Spear 2 - 20" N = Buna N

10 = 1.0 micron 6 = 226 O-Ring Flat 3 - 30" S = Silicone

15 = 1.5 micron 7 = 226 O-Ring Spear 4 - 40" V = Viton

25 = 2.5 micron F = DOE Flat Gasket 5 = 5" T = TEV*

45 = 4.5 micron S = SOE Flat Gasket 9 = 9.75" U = TES*

1X = 10 micron

2X = 20 micron

* - not av ailable in Code Z ** - only av ailable in 5", 10" and 20"

Z = SOE Internal 213 O-ring

Flat **

NDP = Depth Pleated

Polypropylene

6 = 6pc/ pack

(for10" and 20"

only )

Example - Depth Pleated PP Media filter, 10", 2.5 micron cartridge, w ith 2-222 Silicone o-ring, Flat end cap, and no insert w ould be NDP2501S1

-5 = Stainless Steel Insert

Specifications (cont.)

Sterilization & Autoclaving

The filters can be sterilized by autoclaving for up to 25 cycles at 257°F/125°C. The filters can also be sterilized by steam-in-place procedure up to 5 cycles at 275°F/135°C for 30 minutes at less than 0.3 bar differential pressure. The filters can also sanitized by hot water or common chemicals that are compatible with filter components.

Page 103

Page 105: ZenPure - Q-Test

PureFlo® Industrial PP Cartridges

ZenPure Z

en

Pu

re

PureFlo® Industrial polypropylene filter cartridges are graded porosity polypropylene media filters that have been designed for general clarification and pre-filtration applications. The graded porosity design re-moves particles in sequence by size – larger particles by the more open outer layers and smaller particles by the tighter inner layers. The outer layers act as a pre-filter while the inner layers provide the smaller particle retention. The media spreads the contami-nants throughout the matrix resulting in a high con-taminant holding capacity, long lifetime, and low pressure drop.

No adhesives, binders, or surfactants are used in the manufacturing process and the non-woven media does not allow for migration into the process fluid, thereby reducing the potential for extractables and downtime. The all-polypropylene construction pro-vides thermal and chemical compatibility with low and high pH chemicals.

Pleated polypropylene filter cartridges are manufac-tured to ensure consistent filter performance each and every time out of the package.

Applications

Acids Ink Jets

Bases Parts Cleaning

Solvents Lacquers

Fine Chemicals Plating Solutions

Industrial Dyes

Specification

Materials of Construction: Media: Non-Woven Polypropylene Media Supports: Polypropylene Cage, Core, End Caps: Polypropylene O-Rings: Silicone, EPDM, Viton, Buna N, TES, TEV Sealing: Thermally bonded Dimensions (nominal) Lengths: 5 in. (13 cm), 10 in. (25 cm), 20 in. (50 cm), 30 in. (76 cm)

40 in. (102 cm) up to 70” Diameter: 2.75 in. (7 cm)

Effective Filtration Area: 0.5 m2 (5.4 ft2) per 10" cartridge element Available Ratings: 0.6um - 150.0um Operating Conditions: Maximum Forward Differential Pressure: 5.0 bar (73 psid) at 20° C 2.0 bar (29 psid) at 80° C Maximum Reverse Differential Pressure: 3.0 bar (44 psid) at 20° C 1.0 bar (14.5 psid) at 80° C Maximum Operating Temperature: 80° C

Page 104

Page 106: ZenPure - Q-Test

ZenPure PureFlo® Industrial PP Cartridges

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

B17.7 Rev 2011.08

PureFlo Industrial Polypro Filter Cartridge Ordering Guide

PureFlo Industrial PP

Filter CartridgesRemoval Rating End Modifications Length O-Ring / Gasket Materials Inserts

06 = 0.60 micron 0 = 222 O-Ring Flat 1 - 10" E = EPDM Blank = Standard

NIP = Polypropylene 10 = 1 micron 5 = 222 O-Ring Spear 2 - 20" N = Buna N

30 = 3 micron 6 = 226 O-Ring Flat 3 - 30" S = Silicone

50 = 5 micron 7 = 226 O-Ring Spear 4 - 40" V = Viton

70 = 7 micron F = DOE Flat Gasket 5 = 5" T = TEV*

1X = 10 micron S = SOE Flat Gasket 9 = 9.75" U = TES*

2X = 20 micron Y = DOE Internal 213 O-ring**

3X = 30 micron Z = SOE Internal 213 O-ring Flat **

4X = 40 micron

5X = 50 micron

7X = 70 micron

10X = 100 micron

15X = 150 micron

Example - Industrial PP Media filter, 10", 3 micron cartridge, w ith 2-222 Silicone o-ring, Flat end cap, and no insert w ould be NIP3001S

* - not av ailable in Code Z ** - only av ailable in 5", 10" and 20"

-5 = Stainless

Steel Insert

0

2

4

6

8

10

0

0.08

0.16

0.24

0.32

0.4

0.48

0.56

0.64

0 5 10 15

0 8 16 24 32 40 48 56

PureFlo Industrial PolyPro Cartridge

GPM

BarPSID

LPMD

iffe

ren

tia

l

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

3.0

7.0, 10

1.0

5.0

30, 50, 70

0.6

Page 105

Page 107: ZenPure - Q-Test

PureFlo® PTFE Filter Cartridges

ZenPure Z

enP

ure

PureFlo® PTFE filter cartridges are highly retentive hydro-phobic PTFE membrane filters that have been specially designed for critical applications. The PTFE membrane in an all-polypropylene construction provides excellent chemical compatibility and superior flow per unit area as compared to other membrane cartridges. No adhesives, binders, or surfac-tants are used in the manufacturing process and all cartridges are rinsed with high-purity water to reduce extractables and downtime.

The naturally hydrophobic PTFE membrane is ideally suited for aggressive chemicals such as acids, bases, and solvents. In addition, the hydrophobic membrane provides superior flow and pressure drop characteristics per unit area for gas filtration and tank venting applications. All filter cartridges are 100% integrity tested to ensure filter performance each and every time out of the package. PureFlo PTFE filter car-tridges are well-suited for critical applications where superior flow and particle removal efficiency at 0.1 and 0.2 micron is required.

Materials of Construction Membrane: Hydrophobic PTFE Membrane Supports: Polypropylene Cage, Core, End Caps: Polypropylene O-Rings: Silicone, EPDM, Viton, Buna N, TES, and TEV

Dimensions (nominal) Lengths: 5 in. (13 cm), 10 in. (25 cm), 20 in. (50 cm), 30 in. (76 cm), 40 in. (102 cm) Diameter: 2.75 in. (7 cm)

Effective Filtration Area 0.65 m2 (7.0 ft2) per 10" cartridge element

Operating Conditions Maximum Forward Differential Pressure: 6.0 bar (87 psid) at 20 °C 2.0 bar (29 psid) at 80 °C Maximum Reverse Differential Pressure: 3.0 bar (44 psid) at 20 °C 1.0 bar (14.5 psid) at 80 °C Maximum Operating Temperature: 80° C

Applications Acids Ink Jets

Bases Electronics

Solvents Pharmaceuticals

Fine Chemicals Biologics

Plating Solutions Dyes

Parts Cleaning Lacquers

Features Benefits ■ Hydrophobic PTFE Membrane

(Absolute Rated) ■ Consistent and reproducible particulate removal ■ High flow rates and low pressure drops ■ Superior filter lifetime and process throughputs

■ Wide Chemical & Thermal Compatibility ■ Provides excellent compatibility with a wide range of chemicals such as acids, bases, and solvents

■ No media migration into the process fluid

■ Low Filter Extractables ■ No adhesives, binders, or surfactants are used during the manufacturing process resulting in superior downstream cleanliness

■ All cartridges are rinsed with high-purity water to reduce downtime

Page 106

Page 108: ZenPure - Q-Test

ZenPure PureFlo® PTFE Filter Cartridges

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company. Copyright 2003-2012 ZenPure or an affiliated company. All rights reserved.

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

B18 Rev 2011.08

PureFlo PTFE Filter Cartridge Ordering Guide

PureFlo PTFE

Pore Size (micron)

Connections

Length

Gasket / O-Ring Materials

Package Quantity

Inserts

MCF

PTFE with PP Construction

10 = 0.10 20 = 0.20 45 = 0.45 1X = 1.0 3X = 3.0 5X = 5.0 9X = 10

0 = 222 O-Ring Flat 5 = 222 O-Ring Spear 6 = 226 O-Ring Flat 7 = 226 O-Ring Spear F = DOE Flat Gasket S = SOE Flat Gasket Z = SOE Internal 213

O-ring Flat **

1 = 10" 2 = 20" 3 = 30" 4 = 40" 5 = 5" 9 = 9.75"

E = EPDM N = Buna N S = Silicone V = Viton T = TEV * U = TES *

1 = 1 per pack

Blank = Standard -5 = Stainless Steel Insert

Example – 20", 0.20 micron, with 2-222 EPDM O-Rings/Flat Cap and no insert would be MCF2002E1

* - not available in Code Z **- only available in 5", 10", and 20"

SPECIFICATIONS Regulatory Compliance

Manufactured from materials that con-form to the requirements of 21CFR Part 177 of the U.S. Code of Federal Regula-tions and USP Class VI Biological Test for Plastics

Bacterial Retention Complete retention of > 107organisms/cm2 of Brevundimonas diminuta in ac-cordance with the current HIMA chal-lenge methodology (ASTM F838-83). Validation Guide available upon request.

Sterilization & Autoclaving The filters can be sterilized by autoclav-ing for up to 50 cycles at 257°F/125°C. The filters can also be sterilized by steam-in-place procedure up to 50 cycles at 275°F/135°C for 30 minutes at less than 0.3 bar differential pressure. The filters can also sanitized by hot water or com-mon chemicals that are compatible with filter components.

Bio-Safety Filter effluent is non-pyrogenic per USP bacterial endotoxin (<0.25 EU/ml)

0

5

10

15

0

0.2

0.4

0.6

0.8

1

0 2 4 6 8 10

0 5 10 15 20 25 30 35

PureFlo PTFE Cartridge

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

0.1

0.2

Gas

Liquid

0

0.5

1

1.5

2

2.5

3

0

0.05

0.1

0.15

0.2

0 500 1000 1500 2000 2500 3000

0 20 40 60 80 100

PTFE Cartridge Gas Flow Rate - 10"

slpm

BarPSID

scfm

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, Air

0.2um = 0.003um Gas filter

30 PSIG nlet

0.1um

Page 107

Page 109: ZenPure - Q-Test

PureFlo Hi Temp PTFE Filters

(PTFE Membrane w/Hi Temp Nylon construction)

ZenPure Z

en

Pu

re

High Compatibility level

PureFlo® Hi Temp PTFE filter cartridges are highly retentive hydrophobic PTFE membrane filters with Nylon components that have been specially designed for critical liquid and gas sterilization applications as possible alter-native to all Teflon® filters. The PTFE membrane with Ny-lon construction provides excellent chemical compatibility and superior flow per unit area for steam-in-place and hot gas applications. No adhesives, binders, or surfactants are used in the manufacturing process and all cartridges are rinsed with high-purity water to reduce extractables and downtime.

The naturally hydrophobic PTFE membrane with Nylon construction is ideally suited for aggressive chemicals and gas filtration. In addition, the hydrophobic mem-brane provides superior flow and pressure drop charac-teristics per unit area for higher temperature venting ap-plications. All filter cartridges are 100% integrity tested to ensure filter performance each and every time out of the package. PureFlo Hi Temp PTFE filter cartridges are well-suited for critical applications where superior micro-organism removal efficiency is required in a high tem-perature or aggressive environments.

Specification

Materials of Construction: Media: PTFE membrane (hydrophobic) Media Supports: Nylon O-ring insert: Stainless steel 316L option Cage, Core, End Caps: Nylon O-Rings: Silicone, EPDM, Fluoroelastomer, Buna N Effective Filtration Area: 7.0ft2 (0.65m2) per 10" cartridge element Nominal Dimensions: Lengths: 5 in. (13 cm), 10 in. (25 cm), 20 in. (50 cm), 30 in. (76 cm), 40 in. (102cm) Diameter: 2.75 in. (70mm)

Available Ratings: 0.1um, 0.2um (0.01um in Gas), 0.45um, 0.65um, 1.0um, 3.0um,

5.0um, & 10.0um Operating Conditions: Maximum Forward Differential Pressure: 6.0 bar (87 psid) at 20 °C 3.0 bar (44 psid) at 80 °C Maximum Reverse Differential Pressure: 3.0 bar (44 psid) at 20 °C 1.0 bar (14.5 psid) at 80 °C Maximum Operating Temperature: 95° C Regulatory Compliance: The filters are constructed with polypropylene resins and filtration media in compliance with 21CFR Part 177 of the US Code of Federal Regulations and USP Class VI Biological Test for Plastic.

Applications High temp Chemicals Hot Water

Solvent filtration Hot Gas filtration

Tank vent Gas Sterilization

Fine Chemicals Fermentation

Page 108

Page 110: ZenPure - Q-Test

ZenPure PureFlo Hi Temp PTFE Filters

Zen

Pu

re

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

B18.5 Rev 2011.08

Specifications (cont.)

Sterilization & Autoclaving: The filters can be sterilized by autoclaving for up to 100 cycles at 275°F/135°C. The filters can also be sterilized by steam-in-place procedure up to 100 cycles at 287.6°F/142°C for 30 minutes at less than 0.3 bar differential pressure. The filters can also sanitized by hot water or common chemicals that are compatible with filter components.

Retention: For 0.2um (0.003um in Gas) Liquid: Complete retention of > 107organisms/cm2 of Brevundimonas diminuta in accordance with the

current HIMA challenge methodology (ASTM F838-83). Gas: Validated by aerosol bacterial (Staphylococcus aureus and Viral (X174 Bacteriophage) challenge

testing. Integrity tested: All cartridges are 100% integrity tested—Validation Guide available upon request

PureFlo Hi Temp PTFE Filter Cartridge with Nylon Construction Ordering Guide

PureFlo Filter Cartridges Removal Rating End Modifications LengthO-Ring / Gasket

MaterialsPackage Qty Options

10 - 0.10 micron 0 = 222 O-Ring Flat 1 - 10" E = EPDM 1 = 1pc/ pack Blank = Standard

MNF = Hy drophobic 20 - 0.20 micron 5 = 222 O-Ring Spear 2 - 20" N = Buna N

PTFE 45 - 0.45 micron 6 = 226 O-Ring Flat 3 - 30" S = Silicone

W/ Ny lon Construction 1X - 1.0 micron 7 = 226 O-Ring Spear 4 - 40" V = Viton

3X - 3.0 micron F = DOE Flat Gasket 5 = 5" T = TEV*

5X - 5.0 micron S = SOE Flat Gasket 9 = 9.75" U = TES*

9X - 10 micron Y = DOE Internal 213 O-ring**

Z = SOE Internal 213 O-ring Flat **

-5 = Stainless

Steel Insert

Example - PTFE w / Ny lon Construction filter, 10", 0.2 micron cartridge, w ith 2-222 Silicone o-ring, Flat end cap, and no insert w ould be MNF2001S1

* - not av ailable in Code Z ** - only av ailable in 5", 10" and 20"

0

5

10

15

0

0.2

0.4

0.6

0.8

1

0 2 4 6 8 10

0 5 10 15 20 25 30 35

PureFlo PTFE Cartridge

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

0.1

0.2

0

0.5

1

1.5

2

2.5

3

0

0.05

0.1

0.15

0.2

0 500 1000 1500 2000 2500 3000

0 20 40 60 80 100

PTFE Cartridge Gas Flow Rate - 10"

slpm

BarPSID

scfm

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, Air

0.2um

30 PSIG Inlet

0.1um

Gas Liquid

Page 109

Page 111: ZenPure - Q-Test

PureFlo Hi Temp PTFE Filters

(PTFE Membrane w/Hi Temp PP and SS core)

ZenPure Z

en

Pu

re

High Compatibility level

PureFlo® Hi Temp PTFE filter cartridges are highly retentive hydrophobic PTFE membrane filters with High Temperature polypropylene components that have been specially designed for critical liquid and gas sterilization applications. The PTFE membrane with High Temperature construction provides excellent chemical compatibility and superior flow per unit area for steam-in-place and hot gas applications. No adhesives, binders, or surfactants are used in the manufacturing process and all cartridges are rinsed with high-purity water to reduce extractables and downtime.

The naturally hydrophobic PTFE membrane is ideally suited for aggressive chemicals and gas filtration. In addition, the hydrophobic membrane provides superior flow and pressure drop characteristics per unit area for higher temperature venting applications. All filter cartridges are 100% integrity tested to ensure filter performance each and every time out of the package. PureFlo Hi Temp PTFE filter cartridges are well-suited for critical applications where superior flow and particle or microorganism removal efficiency is required in a high temperature environment.

Specification

Materials of Construction: Media: PTFE membrane (hydrophobic) Media Supports: Polypropylene media Core, O-ring insert: Stainless steel 316L Cage, End Caps: High Temperature tolerant polypropylene O-Rings: Silicone, EPDM, Fluoroelastomer, Buna N, Effective Filtration Area: 7.0ft2 (0.65m2) per 10" cartridge element Nominal Dimensions: Lengths: 5 in. (13 cm), 10 in. (25 cm), 20 in. (50 cm), 30 in. (76 cm), 40 in. (102cm) Diameter: 2.75 in. (70mm)

Available Ratings: 0.1um, 0.2um (0.01um in Gas), 0.45um, 0.65um, 1.0um, 3.0um,

5.0um, & 10.0um Operating Conditions: Maximum Forward Differential Pressure: 6.0 bar (87 psid) at 20 °C 4.0 bar (58 psid) at 80 °C Maximum Reverse Differential Pressure: 3.0 bar (44 psid) at 20 °C 1.0 bar (14.5 psid) at 80 °C Maximum Operating Temperature: 80° C Regulatory Compliance: The filters are constructed with polypropylene resins and filtration media in compliance with 21CFR Part 177 of the US Code of Federal Regulations and USP Class VI Biological Test for Plastic.

Applications High Temp Chemicals Hot Water

Solvent filtration Hot Gas filtration

Tank vent Gas Sterilization

Fine Chemicals Fermentation

Page 110

Page 112: ZenPure - Q-Test

ZenPure PureFlo Hi Temp PTFE Filters

Zen

Pu

re

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

B18.6 Rev 2011.07

PureFlo Hi Temp PTFE w/SS Core Filter Cartridge Ordering Guide

PureFlo PTFE Filter

CartridgesRemoval Rating End Modifications Length O-Ring / Gasket Materials Package Qty

10 - 0.10 micron 0 = 222 O-Ring Flat 1 - 10" E = EPDM 1 = 1pc/ pack

MSF = Hy drophobic 20 - 0.20 micron 5 = 222 O-Ring Spear 2 - 20" N = Buna N

PTFE 45 - 0.45 micron 6 = 226 O-Ring Flat 3 - 30" S = Silicone

w / High Temp PP construction 1X - 1.0 micron 7 = 226 O-Ring Spear 4 - 40" V = Viton

Stainless steel core 3X - 3.0 micron F = DOE Flat Gasket 5 = 5" T = TEV*

and SS O-ring insert 5X - 5.0 micron S = SOE Flat Gasket 9 = 9.75" U = TES*

9X - 10 micron

Example - PureFlo Hi Temp PTFE Cartridge, 10", 1.0 micron cartridge, w ith 2-226 Silicone o-ring, Fin end cap, and no insert w ould be MSF1X71S1

Code 6 &7 come w ith an imbedded SS o-ring insert * - not av ailable in Code Z ** - only av ailable in 5", 10" and 20"

Z = SOE Internal 213

O-ring Flat **

Code 6 &7

come with an

embedded

SS O-ring

inser

Specifications (cont.)

Sterilization & Autoclaving: The filters can be sterilized by autoclaving for up to 150 cycles at 275°F/135°C. The filters can also be sterilized by steam-in-place procedure up to 150 cycles at 287.6°F/142°C for 30 minutes at less than 0.3 bar differential pressure. The filters can also sanitized by hot water or common chemicals that are compatible with filter components.

Retention: For 0.2um (0.003um in Gas) Liquid: Complete retention of > 107organisms/cm2 of Brevundimonas diminuta in accordance with the

current HIMA challenge methodology (ASTM F838-83). Gas: Validated by aerosol bacterial (Staphylococcus aureus and Viral (X174 Bacteriophage) challenge

testing. Integrity tested: All cartridges are 100% integrity tested—Validation Guide available upon request

0

5

10

15

0

0.2

0.4

0.6

0.8

1

0 2 4 6 8 10

0 5 10 15 20 25 30 35

PureFlo PTFE Cartridge

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

0.1

0.2

0

0.5

1

1.5

2

2.5

3

0

0.05

0.1

0.15

0.2

0 500 1000 1500 2000 2500 3000

0 20 40 60 80 100

PTFE Cartridge Gas Flow Rate - 10"

slpm

BarPSID

scfm

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, Air

0.2um

30 PSIG Inlet

0.1um

Gas Liquid

Page 111

Page 113: ZenPure - Q-Test

PureFlo Hi Temp PTFE Filters

(PTFE Membrane w/Hi Temp PP construction)

ZenPure Z

en

Pu

re

High Compatibility level

PureFlo® Hi Temp PTFE filter cartridges are highly retentive hydrophobic PTFE membrane filters with High Temperature polypropylene components that have been specially designed for critical liquid and gas sterilization applications. The PTFE membrane with High Temperature construction provides excellent chemical compatibility and superior flow per unit area for steam-in-place and hot gas applications. No adhesives, binders, or surfactants are used in the manufacturing process and all cartridges are rinsed with high-purity water to reduce extractables and downtime.

The naturally hydrophobic PTFE membrane is ideally suited for aggressive chemicals and gas filtration. In addition, the hydrophobic membrane provides superior flow and pressure drop characteristics per unit area for higher temperature venting applications. All filter cartridges are 100% integrity tested to ensure filter performance each and every time out of the package. PureFlo Hi Temp PTFE filter cartridges are well-suited for critical applications where superior flow and particle or microorganism removal efficiency is required in a high temperature environment.

Specification

Materials of Construction: Media: PTFE membrane (hydrophobic) Media Supports: Polypropylene media O-ring insert: Stainless steel 316L Cage, Core, End Caps: High Temperature tolerant polypropylene O-Rings: Silicone, EPDM, Fluoroelastomer, Buna N, Effective Filtration Area: 7.0ft2 (0.65m2) per 10" cartridge element Nominal Dimensions: Lengths: 5 in. (13 cm), 10 in. (25 cm), 20 in. (50 cm), 30 in. (76 cm), 40 in. (102cm) Diameter: 2.75 in. (70mm)

Available Ratings: 0.1um, 0.2um (0.01um in Gas), 0.45um, 0.65um, 1.0um, 3.0um,

5.0um, & 10.0um Operating Conditions: Maximum Forward Differential Pressure: 6.0 bar (87 psid) at 20 °C 3.0 bar (44 psid) at 80 °C Maximum Reverse Differential Pressure: 3.0 bar (44 psid) at 20 °C 1.0 bar (14.5 psid) at 80 °C Maximum Operating Temperature: 80° C Regulatory Compliance: The filters are constructed with polypropylene resins and filtration media in compliance with 21CFR Part 177 of the US Code of Federal Regulations and USP Class VI Biological Test for Plastic.

Applications High temp Chemicals Hot Water

Solvent filtration Hot Gas filtration

Tank vent Gas Sterilization

Fine Chemicals Fermentation

Page 112

Page 114: ZenPure - Q-Test

ZenPure PureFlo Hi Temp PTFE Filters

Zen

Pu

re

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

B18.7 Rev 2011.08

Specifications (cont.)

Sterilization & Autoclaving The filters can be sterilized by autoclaving for up to 100 cycles at 275°F/135°C. The filters can also be sterilized by steam-in-place procedure up to 100 cycles at 287.6°F/142°C for 30 minutes at less than 0.3 bar differential pressure. The filters can also sanitized by hot water or common chemicals that are compatible with filter components.

Retention: For 0.2um (0.003um in Gas) Liquid: Complete retention of > 107organisms/cm2 of Brevundimonas diminuta in accordance with the

current HIMA challenge methodology (ASTM F838-83). Gas: Validated by aerosol bacterial (Staphylococcus aureus and Viral (X174 Bacteriophage) challenge

testing. Integrity tested: All cartridges are 100% integrity tested—Validation Guide available upon request

PureFlo Hi Temp PTFE Filter Cartridge Ordering Guide

PureFlo PTFE Filter

CartridgesRemoval Rating End Modifications Length O-Ring / Gasket Materials Package Qty Inserts

10 - 0.10 micron 0 = 222 O-Ring Flat 1 - 10" E = EPDM 1 = 1pc/ pack Blank = Standard

MBF = Hy drophobic 20 - 0.20 micron 5 = 222 O-Ring Spear 2 - 20" N = Buna N

PTFE w / High Temp PP 45 - 0.45 micron 6 = 226 O-Ring Flat 3 - 30" S = Silicone

Construction 1X - 1.0 micron 7 = 226 O-Ring Spear 4 - 40" V = Viton

3X - 3.0 micron F = DOE Flat Gasket 5 = 5" T = TEV*

5X - 5.0 micron S = SOE Flat Gasket 9 = 9.75" U = TES*

9X - 10 micron

Code 6 &7 come w ith an imbedded SS o-ring insert * - not av ailable in Code Z ** - only av ailable in 5", 10" and 20"

-5 = Stainless

Steel Insert

Z = SOE Internal 213

O-ring Flat **

Example - PureFlo PTFE Cartridge, 10", 1.0 micron cartridge, w ith 2-222 Silicone o-ring, Flat end cap, and no insert w ould be MBF1X01S1

0

5

10

15

0

0.2

0.4

0.6

0.8

1

0 2 4 6 8 10

0 5 10 15 20 25 30 35

PureFlo PTFE Cartridge

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

0.1

0.2

0

0.5

1

1.5

2

2.5

3

0

0.05

0.1

0.15

0.2

0 500 1000 1500 2000 2500 3000

0 20 40 60 80 100

PTFE Cartridge Gas Flow Rate - 10"

slpm

BarPSID

scfm

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, Air

0.2um

30 PSIG Inlet

0.1um

Gas Liquid

Page 113

Page 115: ZenPure - Q-Test

PureFlo® Polyethylene Cartridges

PE membrane on HDPE construction

ZenPure Z

en

Pu

re

PureFlo® Polyethylene cartridges are highly reten-tive and have naturally hydrophobic filters. Polyeth-ylene membrane is a reliable choice for the purifi-cation of aggressive chemicals, compressed gases, and vent applications. The PE membrance on HDPE construction is an excellent economic alternative to more expensive fluoropolymer-based cartridges

No adhesives, binders, or surfactants are used in the manufacturing process. PureFlo polyethylene filter cartridges are absolute rated to ensure consis-tent filter performance each and every time out of the package. All filter cartridges are 100% integrity tested and flushed to ensure filter performance.

Applications

Clarification Solvents

Hard Particle Food & Beverages Vacuum Pump Pharmaceuticals Chemicals Biologics Inks, Dyes Tank Vent Aerator Vent

Specification

Materials of Construction: Media: Polyethylene Media Supports: Polyethylene Shell, Cage, Core, End Caps: HDPE Sealing: Thermally bonded Effective Filtration Area: 0.65m2 (7ft2) per 10” cartridge element Nominal Dimensions: Lengths: 5 in. (13 cm), 10 in. (25 cm), 20 in. (50 cm), 30 in. (76 cm), 40 in. (102cm) Diameter: 2.75 in. (70mm) Available Ratings: 0.2um, 1um, 1.5um, & 2.5um Operating Conditions: Maximum Forward Differential Pressure: 4.1 bar (60 psid) at 20 °C 2.0 bar (29 psid) at 80 °C Maximum Reverse Differential Pressure: 2.0 bar (29 psid) at 20 °C 1.0 bar (14.5 psid) at 80 °C Maximum Operating Temperature: 158°F (70°C) Regulatory Compliance: The filters are constructed with High Density Polyethylene resins and filtration

media in compliance with 21CFR Part 177 of the US Code of Federal Regulations and USP Class VI Biological Test for Plastics.

Page 114

Page 116: ZenPure - Q-Test

ZenPure PureFlo® Polyethylene Cartridges

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

B18.9 Rev 2011.07

PureFlo® Polyethylene Cartridge Ordering Guide

PureFlo PE Filter Cartridges Removal Rating End Modifications Length O-Ring / Gasket Materials Package Qty

20 - 0.20 micron 0 = 222 O-Ring Flat 1 - 10" E = EPDM 1 = 1pc/ pack

MCE = Hy drophobic 1X - 1.0 micron 5 = 222 O-Ring Spear 2 - 20" N = Buna N

PE 2X - 1.5 micron 6 = 226 O-Ring Flat 3 - 30" S = Silicone

W/ PE Construction 3X - 2.5 micron 7 = 226 O-Ring Spear 4 - 40" V = Viton

F = DOE Flat Gasket 5 = 5" T = TEV*

S = SOE Flat Gasket 9 = 9.75" U = TES*

Z = SOE Internal 213

O-ring Flat **

Example - PureFlo PE Cartridge, 10", 1.0 micron cartridge, w ith 2-222 Silicone o-ring, Flat end cap, and no insert w ould be MCE1X01S1

* - not av ailable in Code Z ** - only av ailable in 5", 10" and 20"

Page 115

Page 117: ZenPure - Q-Test

PureFlo® Nylon Filter Cartridges

ZenPure Z

en

Pu

re

PureFlo® nylon filter cartridges are highly-retentive, naturally

hydrophilic nylon membrane filters that have been specially

designed for critical applications. The nylon membrane in an

all-polypropylene construction provides excellent chemical

compatibility and superior flow per unit area as compared to

other membrane cartridges. No adhesives, binders, or surfac-

tants are used in the manufacturing process and all cartridges

are rinsed with high-purity water to reduce extractables and

downtime.

The naturally hydrophilic nylon membrane does not require

pre-wetting with IPA and flushing with DI water, thereby

eliminating a potential source of contamination and hazardous

waste. In addition, unlike hydrophobic filters such as PTFE,

the hydrophilic membrane of nylon reduces the potential for

bubble formation by not de-wetting in out-gassing fluids. All

filter cartridges are 100% integrity tested to ensure filter

performance each and every time out of the package. PureFlo

nylon filter cartridges are well-suited for critical applications

where superior flow and particle removal efficiency at 0.1,

0.2, 0.45, 0.65, 0.85 and 1.2 micron is required.

Features Benefits

■ Naturally Hydrophilic Nylon Membrane

(Absolute Rated)

■ IPA pre-wetting not required – thereby eliminating a

potential source of contamination and disposal waste

■ Reduces downtime and improves throughput

■ Economic alternative to PTFE and PVDF filters

■ No dewetting in outgassing fluids unlike hydrophobic filters

such as polypropylene

■ Built To Exacting Specifications ■ Provides a consistent level of filtration

■ Low Filter Extractables ■ No adhesives, binders, or surfactants are used during

manufacturing resulting in superior downstream cleanliness

■ Cartridges are rinsed with high-purity water

Materials of Construction

Membrane: Naturally Hydrophilic Nylon

Membrane Supports: Polypropylene

Cage, Core, End Caps: Polypropylene

O-Rings: Silicone, EPDM, Viton, Buna N, TES,

TEV

Dimensions (nominal)

Lengths: 5 in. (13 cm), 10 in. (25 cm), 20 in. (50

cm), 30 in. (76 cm), 40 in. (102 cm)

Diameter: 2.75 in. (7 cm)

Effective Filtration Area

0.65 m2 (7.0 ft2) per 10" cartridge element

Operating Conditions

Maximum Forward Differential Pressure:

5 bar (87 psid) at 20 °C

2 bar (29 psid) at 80 °C

Maximum Reverse Differential Pressure:

3.0 bar (44 psid) at 20 °C

1 bar (14.5 psid) at 80 °C

Maximum Operating Temperature: 80° C

Applications

Solvents Ink Jets

Fine Chemicals Parts Cleaning

Plating Solutions Pharmaceuticals

Process Water Biologics

Beverages Dyes

Page 116

Page 118: ZenPure - Q-Test

ZenPure PureFlo® Nylon Filter Cartridges

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

B19 Rev 2011.08

PureFlo Nylon Filter Cartridge Ordering Guide

0

5

10

15

0

0.2

0.4

0.6

0.8

1

0 2 4 6 8 10

0 5 10 15 20 25 30 35

PureFlo Nylon Cartridge

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cp Fluid

0.1

0.2

0.45

0.65

1.0

PureFlo Nylon Filters Removal Rating End Modifications Length O-Ring / Gasket Materials Package Qty Inserts

Cartridge 10 - 0.10 micron 0 = 222 O-Ring Flat 1 - 10" E = EPDM 1= 1pc/ pack Blank = Standard

MCN = Ny lon 20 - 0.20 micron 5 = 222 O-Ring Spear 2 - 20" N = Buna N - 5 = SS Insert

50 - 0.45 micron 6 = 226 O-Ring Flat 3 - 30" S = Silicone

65 - 0.65 micron 7 = 226 O-Ring Spear 4 - 40" V = Viton

85 - 0.85 micron F = DOE Flat Gasket 5 = 5" T = TEV*

1X - 1.2 micron S = SOE Flat Gasket 9 = 9.75" U = TES*

Z = SOE Internal 213 O-ring Flat **

Example - PureFlo Ny lon filter, 10", 0.2 micron cartridge, w ith 2-222 Silicone o-ring, Flat end cap, and no insert w ould be MCN2001S1

* - not av ailable in Code Z ** - only av ailable in 5", 10" and 20"

Regulatory Compliance Manufactured from materials that conform to the requirements of 21CFR Part 177 of the U.S. Code of Federal

Regulations and USP Class VI Biological Test for Plastic.

Sterilization & Autoclaving

The filters can be sterilized by autoclaving for up to 25 cycles at 257°F/125°C. The filters can also be sterilized

by steam-in-place procedure up to 3 cycles at 275°F/135°C for 30 minutes at less than 0.3 bar differential pres-

sure. The filters can also sanitized by hot water or common chemicals that are compatible with filter compo-

nents.

Page 117

Page 119: ZenPure - Q-Test

PureFlo® Nylon Plus Filter Cartridges

ZenPure Z

en

Pu

re

PureFlo® Nylon Plus filter cartridges are highly retentive,

naturally hydrophilic membrane filters that have been spe-

cially designed for high temperature applications. The nylon

membrane with polyester supports in a polypropylene con-

struction provides excellent chemical compatibility and su-

perior flow per unit area as compared to other membrane

cartridges. No adhesives, binders, or surfactants are used in

the manufacturing process and all cartridges are rinsed with

high-purity water to reduce extractables and downtime.

The naturally hydrophilic nylon membrane does not require

pre-wetting with IPA and flushing with DI water, thereby

eliminating a potential source of contamination and hazard-

ous waste. In addition, unlike hydrophobic filters such as

PTFE the hydrophilic nylon membrane reduces the potential

for bubble formation by not de-wetting in out gassing fluids.

All filter cartridges are 100% integrity tested to ensure filter

performance each and every time out of the package.

PureFlo Nylon Plus filter cartridges are well-suited for criti-

cal applications where superior flow and particle removal

efficiency at 0.1, 0.2, 0.45, 0.65, and 1.0 micron is required.

Materials of Construction

Membrane: Nylon 6, 6

Membrane Supports: Polyester

Cage, Core: Polypropylene

End Caps: Polypropylene

O-Rings: Silicone, EPDM, Fluoroelastomer,

Buna N, TES, and TEV

Dimensions (nominal)

Lengths: 5 in. (13 cm), 10 in. (25 cm), 20 in.

(50 cm), 30 in. (76 cm), 40 in. (102 cm)

Diameter: 2.75 in. (7 cm)

Effective Filtration Area

0.6 m2 (6.5 ft2) per 10" cartridge element

Operating Conditions

Maximum Forward Differential Pressure:

5 bar (87 psid) at 20 °C

2 bar (29 psid) at 80 °C

Maximum Reverse Differential Pressure:

3.0 bar (44 psid) at 20 °C

1 bar (14.5 psid) at 80 °C

Maximum Operating Temperature: 80° C

Applications

High Temp Acids

Bases Chemical Distribution

Solvents Pharmaceuticals

Fine Chemicals Biologics

Plating Solutions Dyes

Parts Cleaning Magnetic Coatings

Features Benefits ■ Nylon Plus Construction

(Absolute Rated)

■ Higher temperature range

■ Maximum compatibility range

■ Superior filter lifetime and process throughputs

■ Wide Chemical & Thermal Compatibility ■ Provides excellent compatibility with a wide range

chemicals such as acids, bases, and solvents

■ No media migration into the process fluid

■ Low Filter Extractables ■ No adhesives, binders, or surfactants are used during the

manufacturing process resulting in superior downstream

cleanliness

■ All cartridges are rinsed with high-purity water to reduce

downtime

Page 118

Page 120: ZenPure - Q-Test

ZenPure PureFlo® Nylon Plus Filter Cartridges

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2009 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

B19.3 Rev 2011.08

PureFlo Nylon Plus Filter Cartridge Ordering Guide

SPECIFICATIONS

Regulatory Compliance Manufactured from materials that conform to the requirements of 21CFR Part 177 of the U.S.

Code of Federal Regulations and USP Class VI Biological Test for Plastics

Sterilization & Autoclaving

The filters can be sterilized by autoclaving for up to 25 cycles at 257°F/125°C. The filters can

also be sterilized by steam-in-place procedure up to 3 cycles at 275°F/135°C for 30 minutes at

less than 0.3 bar differential pressure. The filters can also sanitized by hot water or common

chemicals that are compatible with filter components.

0

2

4

6

8

10

0

0.08

0.16

0.24

0.32

0.4

0.48

0.56

0.64

0 2 4 6 8 10

0 5 10 15 20 25 30 35

PureFlo NYLON Plus Cartridge

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cp Fluid

0.1

0.2

0.450.65

1.0

Nylon Plus

Cartridge

Pore Size (micron)

Connections

Length

Gasket / O-Ring Materials

Package Quantity

Inserts

MNN

05 = 0.05 10 = 0.10 20 = 0.20 50 = 0.45 65 = 0.65 1X = 1.0

0 = 222 O-Ring Flat 5 = 222 O-Ring Spear 6 = 226 O-Ring Flat 7 = 226 O-Ring Spear F = DOE Flat Gasket S = SOE Flat Gasket Z = SOE Internal 213

O-ring Flat **

1 = 10" 2 = 20" 3 = 30" 4 = 40" 5 = 5"

E = EPDM N = Buna N S = Silicone V = Fluoro-Elastomer T = TEV * U = TES *

1 = 1 per pack

Blank = Standard - 5 = S t a i n l e s s Steel Insert

Example – 20", 0.20 micron, with 2-222 EPDM O-Rings/Flat Cap and no insert would be MNN2002E1

* - not available in Code Z **- only available in 5", 10", and 20"

Page 119

Page 121: ZenPure - Q-Test

PureFlo® All-Nylon Filter Cartridge

ZenPure Z

en

Pu

re

Materials of Construction

Membrane: Nylon 6,6

Membrane Supports: Nylon

Cage, Core: Nylon

End Caps: Nylon

O-Rings: Silicone, EPDM, Fluoroelastomer,

Buna N, TES, and TEV

Dimensions (nominal)

Lengths: 5 in. (13 cm), 10 in. (25 cm), 20 in. (50 cm), 30

in. (76 cm), 40 in. (102 cm)

Diameter: 2.75 in. (7 cm)

Effective Filtration Area

0.6 m2 (6.5 ft2) per 10" cartridge element

Operating Conditions

Maximum Forward Differential Pressure:

6.0 bar (87 psid) at 20 °C

3.0 bar (44 psid) at 80 °C

Maximum Reverse Differential Pressure:

3.0 bar (44 psid) at 20 °C

1.0 bar (14.5 psid) at 80 °C

Maximum Operating Temperature: 95° C

PureFlo® All-Nylon filter cartridges are highly retentive,

naturally hydrophilic membrane filters that have been spe-

cially designed for high temperature applications. The nylon

membrane in an all-nylon construction provides excellent

chemical compatibility and superior flow per unit area as

compared to other membrane cartridges. No adhesives,

binders, or surfactants are used in the manufacturing process

and all cartridges are rinsed with high-purity water to reduce

extractables and downtime.

The naturally hydrophilic nylon membrane does not require

pre-wetting with IPA and flushing with DI water, thereby

eliminating a potential source of contamination and hazard-

ous waste. In addition, the hydrophilic membrane reduces

the potential for bubble formation by not dewetting in out-

gassing fluids unlike hydrophobic filters such as polypropyl-

ene. All filter cartridges are 100% integrity tested to ensure

filter performance each and every time out of the package.

PureFlo All Nylon filter cartridges are well-suited for criti-

cal applications where superior flow and particle removal

efficiency at 0.1, 0.2, 0.45, 0.65, and 1.0 micron is required.

Features Benefits

■ All Nylon Construction

(Absolute Rated)

■ Higher temperature range

■ Maximum compatibility range

■ Superior filter lifetime and process throughputs

■ Wide Chemical & Thermal Compatibility ■ Provides excellent compatibility with a wide-range chemicals

such as acids, bases, and solvents

■ No media migration into the process fluid

■ Low Filter Extractables ■ No adhesives, binders, or surfactants are used during the manufac-

turing process resulting in superior downstream cleanliness

■ All cartridges are rinsed with high purity water to reduce down-

time

Applications Solvents Ink Jets

Fine Chemicals Industrial

Plating Solutions Parts Cleaning

Process Water Lacquers

Industrial Dyes

Page 120

Page 122: ZenPure - Q-Test

ZenPure PureFlo® All-Nylon Filter Cartridge

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

B19.5 Rev 2011.08

PureFlo All-Nylon Filter Cartridge Ordering Guide

All NYLON Cartridge

Pore Size (micron)

Connections

Length

Gasket / O-Ring Materials

Package Quantity

Inserts

MSN

All Nylon con-struction

05 = 0.05 10 = 0.10 20 = 0.20 50 = 0.45 65 = 0.65 80 = 0.80 1X = 1.2

0 = 222 O-Ring Flat 5 = 222 O-Ring Spear 6 = 226 O-Ring Flat 7 = 226 O-Ring Spear F = DOE Flat Gasket S = SOE Flat Gasket Z = SOE Internal 213

O-Ring Flat **

1 = 10" 2 = 20" 3 = 30" 4 = 40" 5 = 5"

E = EPDM N = Buna N S = Silicone V = Fluoro-Elastomer T = TEV * U = TES *

1 = 1 per pack

Blank = Standard - 5 = S t a i n l e s s Steel Insert

Example – 20", 0.20 micron, with 2-222 EPDM O-Rings/Flat Cap and no insert would be MSN2002E1

* - not available in Code Z **- only available in 5", 10", and 20"

SPECIFICATIONS

Sterilization & Autoclaving

The filters can be sterilized by autoclaving for up to 25 cycles at 257°F/125°C. The filters can also be sterilized by

steam-in-place procedure up to 3 cycles at 275°F/135°C for 30 minutes at less than 0.3 bar differential pressure.

The filters can also sanitized by hot water or common chemicals that are compatible with filter components.

Regulatory Compliance Manufactured from materials that conform to the requirements of 21CFR Part 177 of the U.S. Code of Federal

Regulations and USP Class VI Biological Test for Plastic.

0

2

4

6

8

10

0

0.08

0.16

0.24

0.32

0.4

0.48

0.56

0.64

0 2 4 6 8 10

0 5 10 15 20 25 30 35

PureFlo All NYLON Cartridge

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cp Fluid

0.1

0.2

0.450.65

1.0

Page 121

Page 123: ZenPure - Q-Test

PureFlo Charged Nylon Filters

(Charged Nylon Membrane with PP Construction)

ZenPure Z

en

Pu

re

High Contaminant Removal

PureFlo® Charged Nylon cartridge filters are designed to remove particle smaller that its rated pore size with the power of electrical attraction (adsorption/adhesion). Many particles in water and other liquids have a negative charge that can be captured by attraction to a positively charged filter. This combined with particle size exclusion (sieving) process and impaction/ interception particle capture mechanism make this charged nylon filter extremely efficient. The PureFlo® Charged Nylon cartridges are naturally hydrophilic nylon membrane filters with a Polyester support layer for added wetability of the membrane. The nylon membrane in an all-polypropylene construction provides excellent chemical compatibility and superior flow per unit area as compared to other membrane cartridges. No adhesives, binders, or surfactants are used in the manufacturing process and all cartridges are rinsed with high-purity water to reduce extractables and downtime. All filter cartridges are 100% integrity tested to ensure filter performance each and every time out of the package.

Specification

Materials of Construction: Media: Charged Nylon 6,6 membrane (hydrophilic) Media Supports: Polyester Cage, Core, End Caps: Polypropylene O-Rings: Silicone, EPDM, Fluoroelastomer, Buna N Effective Filtration Area: EPN Version - 6.5Ft2 (0.6m2) per 10" cartridge element MPN Version - 9Ft2 (0.84m2) per 10" cartridge element Nominal Dimensions: Lengths: 5 in. (13 cm), 10 in. (25 cm), 20 in. (50 cm), 30 in. (76 cm), 40 in. (102cm) Diameter: 2.75 in. (70mm)

Available Ratings: 0.05um, 0.1um, 0.2um, 0.45um, 0.65um, 1.0um, Operating Conditions: Maximum Forward Differential Pressure: 5.0 bar (73 psid) at 20 °C 2.0 bar (29 psid) at 80 °C Maximum Reverse Differential Pressure: 3.0 bar (44 psid) at 20 °C 1.0 bar (14.5 psid) at 80 °C Maximum Operating Temperature: 80° C Regulatory Compliance: The filters are constructed with polypropylene resins and filtration media in compliance with 21CFR Part 177 of the US Code of Federal Regulations and USP Class VI Biological Test for Plastic.

Applications DI Water UltraPure Water Critical Parts Cleaning

Endotoxin Minimization

Fine Chemicals Plating Solutions

Page 122

Page 124: ZenPure - Q-Test

ZenPure PureFlo Charged Nylon Filters

Zen

Pu

re

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

B19.6 Rev 2011.08

Specifications (cont.)

Sterilization & Autoclaving: The filters can be sterilized by autoclaving for up to 25 cycles at 257°F/125°C. The filters can also be sterilized by steam-in-place procedure up to 3 cycles at 275°F/135°C for 30 minutes at less than 0.3 bar differential pressure. The filters can also sanitized by hot water or common chemicals that are compatible with filter com-ponents.

PureFlo Charged Nylon Filter Cartridge Ordering Guide

0

5

10

15

0

0.2

0.4

0.6

0.8

1

0 2 4 6 8 10

0 5 10 15 20 25 30 35

PureFlo Charged Nylon Cartridge

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cp Fluid

0.1

0.2

0.45

0.65

1.0

PureFlo Nylon Filters Removal Rating End Modifications LengthO-Ring / Gasket

MaterialsPackage Qty Inserts

05 - 0.05 micron 0 = 222 O-Ring Flat 1 - 10" E = EPDM 1= 1pc/ pack Blank = Standard

EPN = Charged Ny lon 10 - 0.10 micron 5 = 222 O-Ring Spear 2 - 20" N = Buna N -5 = SS Insert

(6.5Ft2) 20 - 0.20 micron 6 = 226 O-Ring Flat 3 - 30" S = Silicone

50 - 0.45 micron 7 = 226 O-Ring Spear 4 - 40" V = Viton

MPN = Charged Ny lon 65 - 0.65 micron F = DOE Flat Gasket 5 = 5" T = TEV*

(9.0 Ft2) 1X - 1.0 micron S = SOE Flat Gasket 9 = 9.75" U = TES*

Z = SOE Internal 213 O-ring Flat **

Example - Charged Ny lon w ith 9ft2, 10", 0.2 micron cartridge, w ith 2-226 Silicone o-ring, Spear, and no insert w ould be MPN2071S1

* - not av ailable in Code Z ** - only av ailable in 5", 10" and 20"

Page 123

Page 125: ZenPure - Q-Test

PureFlo® PES Filter Cartridges

ZenPure Z

en

Pu

re

PureFlo® PES filter cartridges are highly retentive hydrophilic

PES membrane filters that have been specially designed for

critical applications. The PES membrane in an all-

polypropylene construction provides excellent chemical

compatibility and superior flow per unit area as compared to

other membrane cartridges. No adhesives, binders, or sur-

factants are used in the manufacturing process and all car-

tridges are rinsed with high-purity water to reduce ex-

tractables and downtime.

The hydrophilic PES membrane does not require pre-wetting

with IPA and flushing with DI water, thereby eliminating a

potential source of contamination and hazardous waste. In

addition, unlike hydrophobic filters such as PTFE, the hydro-

philic PES membrane reduces the potential for bubble forma-

tion by not de-wetting in outgassing fluids. All filter cartridges

are 100% integrity tested to ensure filter performance each

and every time out of the package. PureFlo PES filter

cartridges are well-suited for critical applications where

superior flow and particle removal efficiency at 0.05, 0.1, 0.2,

0.45, 0.65, 0.80 and 1.2 micron is required.

Materials of Construction

Membrane: Hydrophilic Polyethersulfone

Membrane Supports: Polypropylene

Cage, Core, End Caps: Polypropylene

Gasket / O-Rings: EPDM, Buna N, Silicone, Viton,

TES, and TEV

Dimensions (nominal)

Lengths: 5 in. (13 cm), 10 in. (25 cm),

20 in. (50 cm), 30 in. (76 cm), 40 in. (102 cm)

Diameter: 2.75 in. (7 cm)

Effective Filtration Area

0.65 m2 (7 ft2) per 10" cartridge element

Operating Conditions

Maximum Forward Differential Pressure:

5.0 bar (73 psid) at 20°C

2.0 bar (29 psid) at 80°C

Maximum Reverse Differential Pressure:

3.0 bar (44 psid) at 20°C

1.0 bar (14.5 psid) at 80°C

Maximum Operating Temperature: 80° C

Applications

Acids Ink Jets

Bases Clarification

Solvents Pharmaceuticals

Fine Chemicals Biologics

Plating Solutions Dyes

Process Water Lacquers

Beverages Parts Cleaning

Features Benefits

■ Hydrophilic PES Membrane

(Absolute Rated)

■ IPA pre-wetting not required – thereby eliminating a potential

source of contamination and disposal waste

■ Reduces downtime and improves throughput

■ Economic alternative to PTFE filters

■ No de-wetting in out-gassing fluids, unlike hydrophobic filters

■ Wide Chemical & Thermal Compatibility ■ Provides excellent compatibility with a wide-range of chemicals

■ Low Filter Extractables ■ No adhesives, binders, or surfactants are used during manufac-

turing resulting in superior downstream cleanliness

■ All cartridges are rinsed with high-purity water

Page 124

Page 126: ZenPure - Q-Test

ZenPure PureFlo® PES Filter Cartridges

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

C20 Rev 2011.08

PureFlo PES Filter Cartridge Ordering Guide

PureFlo PES Membrane

Pore Size (micron)

Connections Length Gasket / O-Ring

Materials

Package Quantity

Inserts

MCS PES membrane

with PP construction

05 = 0.05 10 = 0.10 20 = 0.20 50 = 0.45 65 = 0.65 80 = 0.80 1X = 1.20

0 = 222 O-Ring Flat 5 = 222 O-Ring Spear 6 = 226 O-Ring Flat 7 = 226 O-Ring Spear F = DOE Flat Gasket S = SOE Flat Gasket Z = SOE Internal 213

O-Ring Flat **

1 = 10" 2 = 20" 3 = 30" 4 = 40" 5 = 5"

E = EPDM N = Buna N S = Silicone V = Fluoro-Elastomer T = TEV * U = TES *

1 = 1 per pack

Blank = Standard -5 = Stainless Steel Insert

Example – 10", 0.65 micron cartridge, with 2-222 EPDM O-Rings/Flat Cap and no insert would be MCS6501E1

* - not available in Code Z **- only available in 5", 10", and 20"

0

1

2

3

4

5

6

7

8

0 2 4 6 8 10

0 5 10 15 20 25 30 35

PureFlo PES Cartridge

0

0.1

0.2

0.3

0.4

0.5

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

0.1

0.20.45

0.65

1.2

0.05

0.8

Regulatory Compliance Manufactured from materials that conform to the requirements of 21CFR Part 177 of the U.S. Code of Federal

Regulations and USP Class VI Biological Test for Plastic

Sterilization & Autoclaving

The filters can be sterilized by autoclaving for up to 25 cycles at 257°F/125°C. The filters can also be sterilized by

steam-in-place procedure up to 10 cycles at 275°F/135°C for 30 minutes at less than 0.3 bar differential pressure. The

filters can also sanitized by hot water or common chemicals that are compatible with filter components.

Page 125

Page 127: ZenPure - Q-Test

PureFlo® Pharmaceutical Grade Cartridge

ZenPure Z

en

Pu

re

The PureFlo® pharmaceutical grade cartridges are designed to

produce product sterility. The all-polypropylene construction

provides excellent chemical compatibility and superior flow

per unit area as compared to other membrane cartridges.

PureFlo® pharmaceutical grades cartridges have been

designed for final filtration in biopharmaceutical applications.

The hydrophilic PES membrane does not require pre-wetting

agents, thereby eliminating a potential source of contamina-

tion. The PES membrane has low protein-binding characteris-

tics to maximize yields

No adhesives, binders, or surfactants are used in the

manufacturing process. All cartridges are rinsed with

pyrogen-free water to reduce extractables and downtime. All

filter cartridges are 100% integrity tested to ensure filter

performance and quality. PureFlo pharmaceutical grade filter

cartridges are well-suited for critical applications where

superior flow and bacterial retention is required.

SPECIFICATIONS

Bacterial Retention Complete retention of > 107organisms/cm2 of Brevun-

dimonas diminuta in accordance with the current HIMA

challenge methodology (ASTM F838-83). Validation Guide

available upon request. Sterilization & Autoclaving

The filters can be sterilized by autoclaving for up to 25 cy-

cles at 257°F/125°C for the MCS Series and up to 50 cycles

at 257°F/125°C for the MPS Series Filters. The filters can

also be sterilized by steam-in-place procedure up to 10 cy-

cles at 275°F/135°C for the MCS Series and up to 30 cycles

at 275°F/135°C for the MPS Series. Both for 30 minutes at

less than 0.3 bar differential pressure. The filters can also

sanitized by hot water or common chemicals that are com-

patible with filter components.

Water Bubble Point Specification 0.1um : 23psi,0.16 MPA (IPA)

0.2um : 47psi,0.32 MPA

Bio-Safety Filter effluent is non-pyrogenic per USP bacterial endotoxin

(<0.25 EU/ml)

Features Benefits

■ Hydrophilic PES Membrane

(Absolute Rated)

■ Inherently hydrophilic

■ High flow rate reduces processing time

■ Low protein-binding membrane maximizing yields

■ Biologically inert membrane

■ Bacterial retentive to produce sterile solutions

■ Wide Chemical & Thermal Compatibility ■ Provides excellent compatibility with a wide-range of

chemicals

■ Low Filter Extractables ■ No adhesives, binders, or surfactants are used during

manufacturing resulting in superior downstream cleanliness

■ All cartridges are rinsed with pyrogen-free water

Applications

Culture media Fermentation Broths

Serums LVP ( Large Volume

Parenterals)

Vaccines Pharmaceuticals

Fine Chemicals Biologics

Antibiotics Beverages

Water Scale Up Processes

Regulatory Compliance Manufactured from materials that conform to the require-

ments of 21CFR Part 177 of the U.S. Code of Federal Regu-

lations and USP Class VI Biological Test for Plastics.

Page 126

Page 128: ZenPure - Q-Test

ZenPure PureFlo® Pharmaceutical Grade Cartridge

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

C21 Rev 2011.08

PureFlo PES Pharmaceutical Grade Filter Cartridge Ordering Guide

0

1

2

3

4

5

6

7

8

0 2 4 6 8 10

0 5 10 15 20 25 30 35

PureFlo PES Cartridge

0

0.1

0.2

0.3

0.4

0.5

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

0.1

0.20.45

0.65

1.2

0.04

0.8

10” Element

PureFlo PES Filter

CartridgesRemoval Rating End Modifications Length

O-Ring /

Gasket Package Qty Inserts Pharm Grade

04 = 0.04 micron 0 = 222 O-Ring Flat 1 = 10" E = EPDM 1 = 1pc/ pack Blank = Standard -PH = Pharma Grade

MCS = Single Lay er 10 = 0.10 micron 5 = 222 O-Ring Spear 2 = 20" N = Buna N - 5 = SS Insert -ETO = ETO Sterilization

20 = 0.20 micron 6 = 226 O-Ring Flat 3 = 30" S = Silicone

MPS = Dual Lay er 50 = 0.45 micron 7 = 226 O-Ring Spear 4 = 40" V = Viton

65 = 0.65 micron F = DOE Flat Gasket 5 = 5" T = TEV*

1X = 1.20 micron S = SOE Flat Gasket U = TES*

Z = SOE Internal 213

O-ring Flat **-S(pore Size) = PES PreFilter

-G(pore Size)= Glass Fiber

PreFilter

-P(pore Size)= Poly Pro Media

PreFilter

Ex ample - Pharmaceutical grade, 10", 0.2 micron cartridge, w ith 2-222 Silicone o-ring, Flat end cap, and no insert w ould be MCS2001S1-PH

* - not av ailable in Code Z ** - only av ailable in 5", 10" and 20"

Effective Filtration Area

0.65 m2 (7 ft2) per 10" cartridge element

Operating Conditions

Maximum Forward Differential Pressure:

5.0 bar (73 psid) at 68°F/20°C

2.0 bar (29 psid) at 176°F/80°C

Maximum Reverse Differential Pressure:

3.0 bar (44 psid) at 68°F/20°C

1.0 bar (14.5 psid) at 176°F/80°C

Maximum Operating Temperature: 176°F/80°C

Materials of Construction

Membrane: Hydrophilic Polyethersulfone

Membrane Supports: Polypropylene

Cage, Core, End Caps: Polypropylene

Gasket / O-Rings: EPDM, Buna N, Silicone,

Viton, TES, and TEV

Dimensions (nominal)

Lengths: 5 in. (13 cm), 10 in. (25 cm),

20 in. (50 cm), 30 in. (76 cm), 40 in. (102 cm)

Diameter: 2.75 in. (7 cm)

Page 127

Page 129: ZenPure - Q-Test

PureFlo® Biological Reduction Grade Cartridge

ZenPure Z

en

Pu

re

Materials of Construction

Membrane: Hydrophilic Polyethersulfone

Membrane Supports: Polypropylene

Cage, Core, End Caps: Polypropylene

Gasket / O-Rings: EPDM, Buna N, Silicone,

Viton, TES, and TEV

Dimensions (nominal)

Lengths: 5 in. (13 cm), 10 in. (25 cm), 20 in.

(50 cm), 30 in. (76 cm), 40 in. (102 cm)

Diameter: 2.75 in. (7 cm)

Effective Filtration Area

0.65 m2 (7 ft2) per 10" cartridge element

Sterilization & Autoclaving

The filters can be sterilized by autoclaving for

up to 50 cycles at 257°F/125°C. The filters can

also be sterilized by steam-in-place procedure

up to 30 cycles at 275°F/135°C for 30 minutes

at less than 0.3 bar differential pressure. The

filters can also sanitized by hot water or com-

mon chemicals that are compatible with filter

components.

Water Bubble Point Specification 0.1um : 23psi,0.16 MPa (IPA)

0.2um : 45psi,0.32 MPa

Operating Conditions

Maximum Forward Differential Pressure:

5.0 bar (73 psid) at 68°F/20°C

2.0 bar (29 psid) at 176°F/80°C

Maximum Reverse Differential Pressure:

3.0 bar (44 psid) at 68°F/20°C

1.0 bar (14.5 psid) at 176°F/80°C

Maximum Operating Temperature: 176°F/80°C

PureFlo® biological reduction grade cartridges are highly re-

tentive hydrophilic PES membrane filters that have been de-

signed for critical solutions in the pharmaceutical industry.

The PES membrane in an all-polypropylene construction pro-

vides excellent chemical compatibility. The PureFlo®

biological reduction grade cartridge has superior flow per unit

area as compared to other membrane cartridges. No adhe-

sives, binders, or surfactants are used in the manufacturing

process. All cartridges are rinsed with high-purity water to

reduce extractables and downtime.

The PureFlo® membrane is inherently hydrophilic and does

not require pre-wetting with IPA and flushing with DI water.

This eliminates a potential source of contamination and haz-

ardous waste. All filter cartridges are 100% integrity tested to

ensure filter integrity each and every time. PureFlo biological

grade cartridges are well-suited for critical applications where

superior flow, microbial reduction and particle retention at 0.1,

0.2, 0.45, 0.65 and 0.8 micron are needed. The PES

membrane also exhibits low protein-binding characteristics.

Benefits

■ Superior flow rate reducing process time

■ Long service life

■ Biologically inert

■ Low protein binding, maximizing yields

■ Integrity testable

■ All cartridges are rinsed with high-purity water

■ Provides excellent compatibility with a wide-range of

chemicals

Applications

Serums Vaccines

Biologicals Prefiltration

Bacterial Growth Media Pharmaceutical

Intermediates

Reagent Chemicals Biologics

Fermentation Broths Ophthalmic Solutions

Process Water Liquids

Page 128

Page 130: ZenPure - Q-Test

ZenPure PureFlo® Biological Reduction Grade Cartridge

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

C21.2 Rev 2011.08

PureFlo Biological Grade Ordering Guide

PureFlo PES Membrane

Pore Size (micron)

Connections

Length

Gasket / O-Ring

Materials

Package Quantity

Inserts

MCS

PES Membrane with PP

construct on

10 = 0.10 20 = 0.20 50 = 0.45 65 = 0.65 80 = 0.80 1X = 1.20

0 = 222 O-Ring Flat 5 = 222 O-Ring Spear 6 = 226 O-Ring Flat 7 = 226 O-Ring Spear F = DOE Flat Gasket S = SOE Flat Gasket Z = SOE Internal 213

O-ring Flat **

1 = 10" 2 = 20" 3 = 30" 4 = 40" 5 = 5"

E = EPDM N = Buna N S = Silicone V = Viton T = TEV * U = TES *

1 = 1 per pack

-B= Biological R e d u c t i o n Grade -5 = Stainless Steel Insert

Example – 10", 0.65 micron cartridge, with 2-222 EPDM O-Rings/Flat Cap and no insert would be MCS6501E1-B * - not available in Code Z **- only available in 5", 10", and 20"

0

1

2

3

4

5

6

0 2 4 6 8 10

0 5 10 15 20 25 30 35

PureFlo PES Cartridge

0

0.05

0.1

0.15

0.2

0.25

0.3

0.35

0.4

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

0.1

0.2

0.45

0.65

1.20.8

10” Element

Regulatory Compliance

Manufactured from materials that conform to the requirements of 21CFR Part 177 of the U.S. Code of

Federal Regulations and USP Class VI Biological Test for Plastics

Page 129

Page 131: ZenPure - Q-Test

PureFlo® BEV Filter Cartridges

ZenPure Z

en

Pu

re

PureFlo® BEV filter cartridges are highly-retentive

hydrophilic PES membrane filters. The BEV filter has been

designed for beverage applications. The PES membrane, with

polyester supports and nylon end caps, provided excellent

wettability. No adhesives, binders, or surfactants are used in

the manufacturing process. All cartridges are rinsed with high

-purity water to reduce extractables.

The hydrophilic PES membrane ,with the polyester supports

and nylon end caps, enhances the PES pore structure to make

it spontaneously wet out in your liquid beverage. No prewet-

ting with IPA and flushing with DI water required, thus, elimi-

nating a potential source of contamination and hazardous

waste. All filter cartridges are flushed and 100% integrity

tested to ensure filter performance each and every time. Pure-

Flo BEV filter cartridges are well-suited for critical applica-

tions where superior flow and particle removal efficiency at

0.1, 0.2, 0.45, 0.65, and 1.2 micron is required.

Dimensions (nominal)

Lengths: 5 in. (13 cm), 10 in. (25 cm), 20 in.

(50 cm), 30 in. (76 cm), 40 in. (102 cm)

Diameter: 2.75 in. (7 cm)

Effective Filtration Area

0.65 m2 (7.0 ft2) per 10" cartridge element

Operating Conditions

Maximum Forward Differential Pressure:

5.0 bar (73 psid) at 68°F/20°C

2.0 bar (29 psid) at 176°F/80°C

Maximum Reverse Differential Pressure:

3.0 bar (44 psid) at 68°F/20°C

1.0 bar (14.5 psid) at 176°F/80°C

Maximum Operating Temperature: 176°F/80°C

Features Benefits

■ Hydrophilic PES Membrane

■ IPA pre-wetting not required – thereby eliminating a potential

source of contamination and disposal waste

■ Reduces downtime and improves throughput

■ Wide Chemical & Thermal Compatibility ■ Provides excellent compatibility with a wide-range of

chemicals

■ Low Filter Extractables ■ No adhesives, binders, or surfactants are used during

manufacturing resulting in superior downstream cleanliness

■ All cartridges are rinsed with high-purity water

Applications

Wines Beers

Liquids Juices

Syrups Beverages

Process Water Potable Water

Materials of Construction

Membrane: Hydrophilic Polyethersulfone

Membrane Supports: Polyester

Cage and Core: Polypropylene

End Caps: Nylon

Gasket / O-Rings: EPDM, Buna N, Silicone, Viton,

TES, and TEV

Page 130

Page 132: ZenPure - Q-Test

ZenPure PureFlo® BEV Filter Cartridges

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

C21.5 Rev 2011.08

PureFlo BEV Filter Cartridge Ordering Guide

0

0.5

1

1.5

2

2.5

3

3.5

4

0 2 4 6 8 10

0 5 10 15 20 25 30 35

PureFlo PES BEV Cartridge

0

0.05

0.1

0.15

0.2

0.25

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

0.1

0.2

0.450.65

1.2

SPECIFICATIONS Regulatory Compliance

Manufactured from materials that conform to the requirements of 21CFR Part 177 of the U.S. Code of Federal

Regulations and USP Class VI Biological test for Plastics

Sterilization & Autoclaving

The filters can be sterilized by autoclaving for up to 25 cycles at 257°F/125°C. The filters can also be sterilized

by steam-in-place procedure up to 10 cycles at 275°F/135°C for 30 minutes at less than 0.3 bar differential pres-

sure. The filters can also sanitized by hot water or common chemicals that are compatible with filter components.

10” Element

PureFlo PES Membrane

Pore Size (micron)

Connections

Length

Gasket / O-Ring

Materials

Package Quantity

Inserts

MBS

10 = 0.10 20 = 0.20 50 = 0.45 65 = 0.65 1X = 1.20

0 = 222 O-Ring Flat 5 = 222 O-Ring Spear 6 = 226 O-Ring Flat 7 = 226 O-Ring Spear F = DOE Flat Gasket S = SOE Flat Gasket Z = SOE Internal 213

O-Ring Flat **

1 = 10" 2 = 20" 3 = 30" 4 = 40" 5 = 5"

E = EPDM N = Buna N S = Silicone V = Viton T = TEV * U = TES *

1 = 1 per pack Blank = Stan-dard -5 = Stainless Steel Insert

Example – 10", 0.65 micron cartridge, with 2-222 EPDM O-Rings/Flat Cap and no insert would be MBS6501E1

* - not available in Code Z **- only available in 5", 10", and 20"

Page 131

Page 133: ZenPure - Q-Test

PureFlo® EPS Filter Cartridge

(PES/PP layered)

ZenPure Z

en

Pu

re

Specifications

Materials of Construction: Membrane: Hydrophilic PES with Polypropylene media prefilter Membrane Supports: Polypropylene Cage, Core, End Caps: Polypropylene Gasket/O-ring: EPDM, Buna N, Silicon, Fluoroelastomer, TES, and TEV Sealing: Thermally welded

Fitting Connections: 222, 226, DOE, SOE, internal 213 with Flat or Spear

Nominal Dimensions: Lengths: 5 in. (13 cm), 10 in. (25 cm), 20 in. (50 cm), 30 in. (76 cm), 40 in. (102 cm) Diameter: 2.75 in. (7 cm)

Effective Filtration Area: 0.65 m2 (7 ft2) per 10" cartridge element

Operating Conditions: Maximum Forward Differential Pressure: 5.0 bar (73 psid) at 68°F/20°C 2.0 bar (29 psid) at 176°F/80°C Maximum Reverse Differential Pressure: 3.0 bar (44 psid) at 68°F/20°C 1.0 bar (14.5 psid) at 176°F/80°C Maximum Operating Temperature: 176°F/80°C

Sterilization & Autoclaving: The filters can be sterilized by autoclaving for up to 25 cycles at 257°F/125°C. The filters can also be sterilized by steam-in-place procedure up to 10 cycles at 275°F/135°C for 30 minutes at less than 0.3 bar differential pressure. The filters can also sanitized by hot water or common chemicals that are compatible with filter com-ponents.

PureFlo® EPS biological reduction grade cartridges are highly retentive, hydrophilic PES membrane filters with a Polypropylene pre-filters layer. They have been designed for critical solutions in the pharmaceutical industry. The PES membrane in an all-polypropylene construction provides excellent chemical compatibility. The PureFlo® EPS Series Cartridge has superior flow per unit area as compared to other membrane car-tridges. No adhesives, binders, or surfactants are used in the manufacturing process. All cartridges are rinsed with high-purity water to reduce extractables and downtime.

The PureFlo® PES membrane is inherently hydrophilic and does not require pre-wetting with IPA and flush-ing with DI water. This eliminates a potential source of contamination and hazardous waste. All filter car-tridges are 100% integrity tested to ensure filter in-tegrity each and every time. PureFlo EPS cartridges are well-suited for critical applications where superior flow, microbial and particle retention at 0.1, 0.2, 0.45, 0.65 and 0.8 micron are needed. The PES membrane also exhibits low protein-binding charac-teristics.

Applications Serums Vaccines

Biologicals Prefiltration

Bacterial Growth Media Pharmaceutical

Intermediates

Reagent Chemicals Biologics

Fermentation Broths Ophthalmic Solutions

Process Water Liquids

Page 132

Page 134: ZenPure - Q-Test

ZenPure PureFlo® EPS Series Filter Cartridge

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

C21.6 Rev 2011.08

PureFlo EPS Series Filter Cartridge Ordering Guide

0

1

2

3

4

5

6

7

8

0 2 4 6 8 10

0 5 10 15 20 25 30 35

PureFlo PES Cartridge

0

0.1

0.2

0.3

0.4

0.5

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

0.1

0.20.45

0.65

1.2

0.04

0.8

PureFlo EPS Filter

CartridgesRemoval Rating End Modifications Length

O-Ring / Gasket

MaterialsPackage Qty PP Second Layer Options

04 - 0.04 micron 0 = 222 O-Ring Flat 1 - 10" E = EPDM 1 = 1pc/ pack -P003 = 0.30u

EPS 10 - 0.10 micron 5 = 222 O-Ring Spear 2 - 20" N = Buna N -P006 = 0.60u

20 - 0.20 micron 6 = 226 O-Ring Flat 3 - 30" S = Silicone -P010 = 1u - 5 = SS Insert

50 - 0.45 micron 7 = 226 O-Ring Spear 4 - 40" V = Viton -P030 = 3u

65 - 0.65 micron F = DOE Flat Gasket 5 = 5" T = TEV* -P050 = 5u

80 - 0.80 micron S = SOE Flat Gasket U = TES* -P070 = 7u

1X - 1.20 micron Z = SOE Internal 213

O-ring Flat **

-P100 = 10u

PES Membrane w ith PP

prefilter

-B =Bio-Reduction

grade

Example - EPS Filter, 10", 0.45 micron PES, w ith 226 Silicone o-ring w ith Spear and 1.0um PP prefilter, and no insert w ould be EPS5071S1-P010-B

* - not av ailable in Code Z ** - only av ailable in 5", 10" and 20"

Regulatory Compliance: The filters are constructed with polypropylene resins and filtration media in compliance with 21CFR Part 177 of the US Code of Federal Regula-tions and USP Class VI Biological Test for Plastic.

Page 133

Page 135: ZenPure - Q-Test

PureFlo® General Grade Cartridges

ZenPure Z

en

Pu

re

PureFlo® general grade (PES) filter cartridges are a cost-

effective alternative to standard or pharmaceutical grade

cartridges for prefiltration of aqueous-based liquids. The PES

membrane in a high-purity all polypropylene construction pro-

vides excellent chemical compatibility and competitive flow

rates per unit area. No adhesives, binders, or surfactants are

used in the manufacturing process.

The hydrophilic PES membrane does not require pre-wetting

with IPA then flushing with water, thereby eliminating a

potential source of contamination and hazardous waste. In

addition, unlike hydrophobic filters such as polypropylene and

PTFE, the hydrophilic membrane reduces the potential for

bubble formation by not de-wetting in out-gassing fluids.

General grade PES filter cartridges are fabricated and

packaged under clean room conditions.

Materials of Construction

Membrane: Hydrophilic Polyethersulfone

Membrane Supports: Polypropylene

Cage, Core, End Caps: Polypropylene

Gasket / O-Rings: EPDM, Buna N, Silicone, Viton, TES,

and TEV

Dimensions (nominal)

Lengths: 5 in. (13 cm), 10 in. (25 cm),

20 in. (50 cm), 30 in. (76 cm), 40 in. (102 cm)

Diameter: 2.75 in. (7 cm)

Effective Filtration Area

0.6 m2 (6.5 ft2) per 10" cartridge element

Operating Conditions

Maximum Forward Differential Pressure:

5.0 bar (73 psid) at 68°F/20°C

2.0 bar (29 psid) at 176°F/80°C

Maximum Reverse Differential Pressure:

3.0 bar (44 psid) at 68°F/20°C

1.0 bar (14.5 psid) at 176°F/80°C

Maximum Operating Temperature: 176°F/80°C

Applications

Inks

Dyes

Parts Cleaning

Process Water

Plating Solutions

Liquid Clarification

Features Benefits

■ Hydrophilic PES Membrane

(Absolute Rated)

■ IPA pre-wetting not required – thereby eliminating a potential

source of contamination and disposal waste

■ Reduces downtime and improves throughput

■ No adhesives, binders, or surfactants are used during

manufacturing resulting in superior downstream cleanliness

■ Wide Chemical & Thermal Compatibility ■ Provides excellent compatibility with a wide-range of

chemicals

■ Economic Filtration ■ Cost-effective product

Page 134

Page 136: ZenPure - Q-Test

ZenPure PureFlo® PES Filter Cartridges General Grade

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

C22 Rev 2011.08

PES Filter Cartridge Ordering Guide - General Grade

PES Filter Cartridges Removal Rating End Modifications Length O-Ring / Gasket Materials Package Qty Inserts

04 - 0.04 micron 0 = 222 O-Ring Flat 1 - 10" E = EPDM 1 = 1pc/ pack Blank = Standard

MGS 10 - 0.10 micron 5 = 222 O-Ring Spear 2 - 20" N = Buna N

20 - 0.20 micron 6 = 226 O-Ring Flat 3 - 30" S = Silicone

50 - 0.45 micron 7 = 226 O-Ring Spear 4 - 40" V = Viton

65 - 0.65 micron F = DOE Flat Gasket 5 = 5" T = TEV*

80 - 0.80 micron S = SOE Flat Gasket U = TES*

1X - 1.20 micronZ = SOE Internal 213

O-Ring Flat **

**- only av alible in 5",

10", and 20"*-not av alible in Code Z

Ex ample - PES General Grade, 10", 0.2 micron cartridge, w ith 2-222 Silicone o-ring, Flat end cap, and no insert w ould be MGS2001S1

- 5 = Stainless

Steel Insert

0

1

2

3

4

5

6

7

8

0 2 4 6 8 10

0 5 10 15 20 25 30 35

PES General Grade Cartridge

0

0.1

0.2

0.3

0.4

0.5

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

0.1

0.20.45

0.65

1.2

0.04

0.8

Regulatory Compliance

Manufactured from materials

that conform to the require-

ments of 21CFR Part 177 of

the U.S. Code of Federal

Regulations and USP Class

VI Biological Test for Plastics

Sanitizing Agents

Cartridges may be sanitized

by common chemical sani-

tizing agents that are com-

patible with filter components.

Page 135

Page 137: ZenPure - Q-Test

PES Filter Cartridge—Water Grade

ZenPure Z

en

Pu

re

Water grade Polyethersulfone (PES) filter cartridges are a cost

-effective alternative to standard or pharmaceutical grade

cartridges for the filtration of aqueous-based liquids. The

PES membrane in a high-purity all polypropylene construc-

tion provides excellent chemical compatibility and competi-

tive flow rates per unit area. No adhesives, binders, or surfac-

tants are used in the manufacturing process.

The hydrophilic PES membrane does not require pre-wetting

with IPA then flushing with water, thereby eliminating a

potential source of contamination and hazardous waste. In

addition, unlike hydrophobic filters such as polypropylene and

PTFE, the hydrophilic membrane reduces the potential for

bubble formation by not de-wetting in out-gassing fluids.

Water grade PES filter cartridges are fabricated and packaged

under cleanroom conditions.

Materials of Construction

Membrane: Hydrophilic Polyethersulfone

Membrane Supports: Polypropylene

Cage, Core, End Caps: Polypropylene

Gasket / O-Rings: EPDM, Buna N, Silicone, Viton,

TES, and TEV

Dimensions (nominal)

Lengths: 5 in. (13 cm), 10 in. (25 cm), 20 in. (50 cm),

30 in. (76 cm), 40 in. (102 cm)

Diameter: 2.75 in. (7 cm)

Effective Filtration Area

0.52 m2 (5.6ft2) per 10" cartridge element

Operating Conditions

Maximum Forward Differential Pressure:

5.0 bar (73 psid) at 68°F/20°C

2.0 bar (29 psid) at 176°F/80°C

Maximum Reverse Differential Pressure:

3.0 bar (44 psid) at 68°F/20°C

1.0 bar (14.5 psid) at 176°F/80°C

Maximum Operating Temperature: 176°F/80°C

Features Benefits

■ Hydrophilic PES Membrane

(Absolute Rated)

■ IPA pre-wetting not required – thereby eliminating a potential

source of contamination and disposal waste

■ Reduces downtime and improves throughput

■ No adhesives, binders, or surfactants are used during

manufacturing resulting in superior downstream cleanliness

■ Wide Chemical & Thermal Compatibility ■ Provides excellent compatibility with a wide-range of

chemicals

■ Economic Filtration ■ Cost-effective product

Applications

Inks Pre Filter for Water

Dyes DI Water

Parts Cleaning Process Water

Process Water Chemicals

Plating Solutions Acids

Liquid Clarification Bases

Page 136

Page 138: ZenPure - Q-Test

ZenPure PES Filter Cartridge – Water Grade

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

C23 Rev 2011.08

PES Filter Cartridge Ordering Guide - General Grade

Regulatory Compliance

Manufactured from materials

that conform to the require-

ments of 21CFR Part 177 of

the U.S. Code of Federal

Regulations and USP Class

VI Biological Test for Plastics

Sanitizing Agents

Cartridges may be sanitized

by common chemical sani-

tizing agents that are com-

patible with filter components.

0

1

2

3

4

5

6

7

8

0 2 4 6 8 10

0 5 10 15 20 25 30 35

PES Cartridge - Water Grade

0

0.1

0.2

0.3

0.4

0.5

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

0.1

0.2

0.450.65

1.2

0.04

0.8

PES Filter Cartridges Removal Rating End Modifications Length O-Ring / Gasket Materials Package Qty Inserts

04 - 0.04 micron 0 = 222 O-Ring Flat 1 - 10" E = EPDM 1 = 1pc/ pack Blank = Standard

MWS 10 - 0.10 micron 5 = 222 O-Ring Spear 2 - 20" N = Buna N

Water Grade 20 - 0.20 micron 6 = 226 O-Ring Flat 3 - 30" S = Silicone

50 - 0.45 micron 7 = 226 O-Ring Spear 4 - 40" V = Viton

65 - 0.65 micron F = DOE Flat Gasket 5 = 5" T = TEV*

80 - 0.80 micron S = SOE Flat Gasket U = TES*

1X - 1.20 micronZ = SOE Internal 213

O-Ring Flat **

**- only av alible in 5",

10", and 20"*-not av alible in Code Z

Ex ample - Water Grade, 10", 0.2 micron cartridge, w ith 2-222 Silicone o-ring, Flat end cap, and no insert w ould be MWS2001S1

- 5 = Stainless

Steel Insert

Page 137

Page 139: ZenPure - Q-Test

PureFlo® Glass MicroFiber Filter Cartridges

ZenPure Z

en

Pu

re

PureFlo® borosilicate microfiber filter cartridges are highly

retentive filters that have a pleated design to maximize surface

area. The borosilicate microfiber media in an all polypropyl-

ene construction provides excellent chemical compatibility

and superior flow per surface area. No adhesives or

surfactants are used in the manufacturing process. The

borosilicate microfiber is “non-fiber releasing.”

The borosilicate microfiber is ideally-suited for microbial

reduction. In addition, the media provides superior flow and

pressure drop characteristics per unit area. PureFlo® microfi-

ber filter cartridges are well-suited for critical applications

where superior flow and particle retention for deformable and

non-deformable particle removal is required. Materials of Construction

Media: Borosilicate Microfiber

Membrane Supports: Polypropylene

Cage, Core, End Caps: Polypropylene

O-Rings: Silicone, EPDM, Viton, Buna N, TES,

and TEV

Dimensions (nominal)

Lengths: 5 in. (13 cm), 10 in. (25 cm), 20 in. (50 cm),

30 in. (76 cm), 40 in. (102 cm)

Diameter: 2.75 in. (7 cm)

Effective Filtration Area

0.47 m2 (5.0 ft2) per 10" cartridge element

Operating Conditions

Maximum Forward Differential Pressure:

5.0 bar (72.5 psid) at 68°F/20° C

2.0 bar (29 psid) at 176°F/80° C

Maximum Reverse Differential Pressure:

3.0 bar (43.5 psid) at 68°F/20° C

1.0 bar (14.5 psid) at 176°F/80° C

Maximum Operating Temperature: 176°F/80°C

Features Benefits

■ Borosilicate Microfiber media

■ High dirt-loading capacity

■ Superior filter lifetime and process throughputs

■ Wide Chemical & Thermal Compatibility ■ Provides excellent compatibility with a wide range of

chemicals

■ No media migration into the process fluid

■ Quality Construction ■ No adhesives, binders, or surfactants are used during the

manufacturing process resulting in superior downstream

cleanliness

■ Thermally welded construction to eliminate bypass

Applications

Prefiltration Biologics

Serums Bio-Burden Reduction

Pharmaceuticals Retention of

Deformable Particles

Wine Clarification Inks

Food & Beverage Cosmetics

Page 138

Page 140: ZenPure - Q-Test

ZenPure PureFlo® Glass MicroFiber Filter Cartridges

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

C23.5 Rev 2011.08

Glass Fiber Membrane

Type

Pore Size (micron)

Connections Length Gasket / O-Ring

Materials

Package Quantity

Inserts

NCG

Glass Fiber with PP

construction

04 = 0.45 05 = 0.5 10 = 1.0 30 = 3.0 50 = 5.0 1X = 10

0 = 222 O-Ring Flat 5 = 222 O-Ring Spear 6 = 226 O-Ring Flat 7 = 226 O-Ring Spear F = DOE Flat Gasket S = SOE Flat Gasket Z = SOE Internal 213

O-Ring Flat **

1 = 10" 2 = 20" 3 = 30" 4 = 40" 5 = 5"

9 = 9.75"

E = EPDM N = Buna N S = Silicone V = Fluro-Elastomer T = TEV * U = TES *

1 = 1 per pack

Blank = Standard 5 = Stainless Steel Insert

Example – 20", 0.20 micron, with 2-222 EPDM O-Rings/Flat Cap and no insert would be NCG2002E1

* - not available in Code Z **- only available in 5", 10", and 20"

PureFlo Glass Microfiber Filter Cartridge Ordering

SPECIFICATIONS Regulatory Compliance

Manufactured from materials that conform to the requirements of USP Class VI Biologi-

cal Test for Plastics

Sterilization & Autoclaving

The filters can be sterilized by autoclaving for up to 25 cycles at 257°F/125°C. The fil-

ters can also be sterilized by steam-in-place procedure up to 10 cycles at 275°F/135°C

for 30 minutes at less than 0.3 bar differential pressure. The filters can also sanitized by

hot water or common chemicals that are compatible with filter components.

0

0.5

1

1.5

0

0.02

0.04

0.06

0.08

0.1

0 2 4 6 8 10

0 5 10 15 20 25 30 35

PureFlo Glass MicroFiber Cartridge

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

10" Cartridge

5.0

10um and above

1.00.5

0.45

3.0

Page 139

Page 141: ZenPure - Q-Test

Thermally Bonded Polypropylene Depth Cartridges

ZenPure Z

en

Pu

re

®

Thermally bonded polypropylene depth filter cartridges

utilize graded density media that is well-suited for clarifi-

cation and pre-filtration applications where high particle

removal is essential. The graded density design efficiently

captures contaminants throughout the media matrix, re-

sulting in excellent contaminant holding capacity, life-

time, and pressure drop. Furthermore, the all-

polypropylene construction provides excellent thermal

and chemical compatibility with high and low high pH

chemicals.

These polypropylene depth filter cartridges come in pore

size ratings of 0.5 to 75 micron with lengths from 5" to

40" to meet your applications. Materials of Construction

Media: Polypropylene Melt Blown Fibers

Dimensions (nominal)

Lengths: 9 3/4", 9 7/8",10",19 1/2", 20", 29

1/4", 30", 39" and 40"

Diameter: 2.5"

Operating Conditions

Maximum Forward Differential Pressure:

3.4 bar (50 psid) at 68°F/20°C

Maximum Reverse Differential Pressure:

3.0 bar (44 psid) at 68°F/20°C

Maximum Operating Temperature:

180°F/82°C

Regulatory Compliance

Manufactured from materials that conform

to the FDA requirements of 21CFR Part 177

of the U.S. Code of Federal Regulations

Features Benefits

■ Graded Density Polypropylene Media

■ Media matrix removes particles throughout the entire

depth of the filter cartridge

■ High flow rates and low pressure drops

■ Economic alternative for high particle level fluids

■ Superior lifetime and throughput

■ 100% Polypropylene Construction ■ Provides excellent thermal and chemical compatibility

with a wide-range of chemicals

■ Quality Manufacturing ■ Consistent and reproducible particle removal

Applications

Pre Reverse Osmosis Ink

Hydrocarbons Electronics

Solvents Water

Fine Chemicals Biologics

Plating Solutions Dyes

Parts Cleaning Gas Processing

Page 140

Page 142: ZenPure - Q-Test

ZenPure Thermally Bonded Polypropylene Depth Cartridges

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

c26 Rev 2011.08

Thermally Bonded Polypropylene Depth Filter Ordering Guide

Thermally Bonded

PolyPro DepthMicron Rating Length Side A Connection Side B Connection Seal Material

JT 1 = 1.0um 9 3/4 = 9 3/4" OE = Open End OE = Open End Blank = No Seal3 = 3.0um 9 7/8 = 9 7/8" EC = Extended Core BAY = Fin/Bayonet E = EPDM

Nominal 5 = 5.0um 10 = 10" 222 = 222 O-Ring C = Closed End Cap B = Buna NRated 10 = 10um 19 1/2 = 19 1/2" 226 = 226 O-Ring EC = Extended Core S = Silicone

20 = 20um 20 = 20" FG = Flat Gasket FG = Flat Gasket SP = Santoprene50 = 50um 29 1/2 = 29 1/2" S = Spring End Cap V = Viton75 = 75um 30 = 30"

39 = 39"40 = 40"

Example – PP depth filter, 5.0 micron cartridge, 20" DOE, would be JT-5-20-OE-OE

Box Quantity Packaging only: 9 3/4” - 10” (30/case) 19 1/2” - 40” (20/case)

0

0.5

1

1.5

2

0

0.02

0.04

0.06

0.08

0.1

0.12

0 1 2 3 4 5

0 4 8 12 16

Thermally Bonded Melt Blown filter

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

10" Standard Element

1um 3um

20um10um

5um

50um75um

Page 141

Page 143: ZenPure - Q-Test

ZenPure Thermally Bonded Polypro 2.5” & 4.5” Cartridges

Zen

Pu

re

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

C27 Rev 2011.08

®

Thermally Bonded Polypropylene double open ended

2.5” & 4.5” diameter filter cartridges utilize graded den-

sity media that is well suited for clarification and pre-

filtration applications where high particle removal is es-

sential. The graded density design efficiently captures

contaminants throughout the media matrix resulting in

excellent contaminant holding capacity, lifetime, and pres-

sure drop. Furthermore, the all polypropylene construction

provides excellent thermal and chemical compatibility

with high and low high pH chemicals.

These economic alternatives for high particle level flu-

ids are consistent and reproducible particle removal

filters. They provides excellent thermal and chemical

compatibility with a wide range of chemicals. These

polypropylene depth filter cartridges come in pore size

ratings from 1 to 50 micron with lengths of 10 and 20

inches to meet your applications.

Applications

Pre-Reverse Osmosis Ink

Home Water Filtration Swimming Pools

Solvents Water

Chemicals Parts Cleaning

Plating Solutions Dyes

Materials of Construction

Media: Polypropylene Melt Blown Fibers

Dimensions (nominal)

Lengths: 10" (9 7/8), 20"

Diameter: 2.5”, 4.5"

Operating Conditions

Maximum Forward Differential Pressure:

3.4 bar (50 psid) at 68°F/20 °C

Maximum Reverse Differential Pressure:

3.0 bar (44 psid) at 68°F/20 °C

Maximum Operating Temperature: 180°F/82°C

Regulatory Compliance

Manufactured from materials that conform to the

FDA requirements of 21CFR Part 177 of the U.S.

Code of Federal Regulations, and NSF Certified.

Thermally Bonded PP 2.5” & 4.5” Filter Cartridge Ordering Guide

Graded Density Outer Middle Inside

1 Micron Filter Layers 20um 5um 1um

5 Micron Filter Layers 30um 10um 5um

10 Micron Filter Layers 30um 20um 10um

20 Micron Filter Layers 50um 30um 20um

50 Micron Filter Layers 100um 100um 50um

10" (2.5" diameter)- 50 to a Case

20" (2.5" diameter)- 25 to a Case

10" (4.5" diameter)- 18 to a Case

20" (4.5" diameter)- 9 to a Case

Density Layers

Case Quantities

Thermally Bonded Polypropylene Removal Rating Length Diameter

00.5 = 0.5 micron 249 = 10" Blank = 2.5"

001 = 1 micron 508 = 20" B = 4.5"

LF-PP = Gradient Density 005 = 5 micron

Polypropylene Filter 010 = 10 micron*

020 = 20 micron

050 = 50 micron

Example: LF-PP-001-508-B is a Thermally bonded PP 4.5" Cartridge, 1 micron, 20" length

*Note: The 10 micron is only available in a 2.5" diameter

Page 142

Page 144: ZenPure - Q-Test

ZenPure PureFlo® Activated Carbon Fiber Cartridge

Zen

Pu

re

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

C28.8 Rev 2011.07

Activated carbon fiber cartridges are designed to re-

move organic compounds, hydrocarbons, chlorine,

color, and odors from aqueous and organic liquids. The

unique fibrous carbon media is designed for maximum

flow and contaminant removal without the release of

carbon fibers. The fibers allow for efficient contact

time and adsorption capacity. Designed with clean,

durable polyethylene end caps, cage and core to pro-

vide superior downstream cleanliness.

No adhesives, binders, or surfactants are used in the

manufacturing process. Each cartridge is manufactured

under tight process control to achieve a uniform prod-

uct with every filter. These activated carbon filters are

available in a range of lengths and connections to suit

your individual purification and filtration needs. The

cartridges are manufactured to fit most single and

multi-round housings.

Materials of Construction

Membrane: Fibrous Activated Carbon

Cage, Core, End Caps: Polypropylene

Gaskets: EPDM, Silicon, Buna N, and Viton

Dimensions (nominal)

Lengths: 10 - 40 in. (250 - 1016 mm)

Diameter: 2.75 in. (70 mm)

Operating Conditions

Maximum Forward Differential Pressure:

4.5 bar (65psi) at 68°F/20°C

2 bar (29psi) at 176°F/80°C

Maximum Reverse Differential Pressure:

3.0 bar (44psi) at 68°F/20°C

1.0 bar (14.5psi) at 176°F/80°C

Maximum Operating Temperature: 176°F/80°C

PureFlo Activated Carbon Fiber Filter Ordering Guide

0

0.5

1

1.5

2

2.5

3

0

0.05

0.1

0.15

0.2

0 5 10 15 20 25

0 20 40 60 80

PureFlo Activated Carbon Cartridge

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @ 22°C, 1cP Fluid

Activated Carbon

Fiber FilterRemoval Rating End Modifications Length

O-Ring / Gasket

MaterialsPackage Qty

0 = 222 O-Ring Flat 1 = 10" E = EPDM 1 = 1pc/ pack

WCC 10 - 10 micron 5 = 222 O-Ring Spear 2 = 20" N = Buna N

(Nominal) 6 = 226 O-Ring Flat 3 = 30" S = Silicone

7 = 226 O-Ring Spear 4 = 40" V = Fluoro-Elastomer

F = DOE Flat Gasket 5 = 5" T = TEV*

S = SOE Flat Gasket 9 = 9.75" U = TES*

*-not av alible in Code Z

Example - One 10" cartridge, w ith DOE Flat EPDM Gasket w ould be WCC10F1E1

Z = SOE Internal 213 O-ring

Flat

Page 143

Page 145: ZenPure - Q-Test

String Wound Filter Cartridges

ZenPure Z

en

Pu

re

String wound filter cartridges are manufactured using a

high speed, continuous wind process which creates a supe-

rior one-piece filter with hundreds of diamond shaped tun-

nels that get progressively smaller from the outer diameter

to the core. Finer particles are progressively trapped as

fluid travels to the center of the filter which allows for a

much greater retention capacity than flat surface filter

media of the same dimensions and porosity.

The 10" and 20" string wound filters have a unique dual

density that is superior to most string wound filters. The

filters are wound at high tension for the first half of the

winding process and then at a lower tension during the

second half of the wind. This produces a superior and ef-

ficient filter that does not blind as quickly, thereby giving

longer filter life with better filtration without compromis-

ing efficiency.

The winding pattern provides 3.5 square feet per each 10

inches of cartridge length. For each 10 inch filter length

there will be approximately 1/2 to 1 pound retention of

solids before replacement becomes necessary. The

amount of solids retained depends on the type of solids in

the solution as well as the head pressure developed by the

pump.

String wound filters can be custom made from 4" to 72"

in length and from 2" to 5" in diameter. We can satisfy

your filtration needs by producing filters with filtration

capabilities from 0.5 microns up to 400 microns.

Materials of Construction

Media: Cotton, Polypropylene, Rayon, Polyes-

ter, Nylon, Fiberglass, and Ryton

Core Material: Polypropylene, Tin Plated Steel,

304 Stainless Steel, 316 Stainless Steel

Core Cover: Polypropylene, Nylon, Fiberglass

Gaskets/ O-rings: EPDM, Buna N, Silicon,

Viton, TEV

Dimensions (nominal)

Lengths: 5" to 40" (up to 72” custom)

Diameters: 2 1/4", 2 3/8", 2 7/16", 4 1/2"

(and custom from 2" to 5")

Features Benefits

■ Dual Density string wound

■ Two zones to provide increased depth filtration that

does not blind as quickly as standard filters

■ Wound in a precise pattern around the core providing

greater surface area. The result is higher dirt-loading

capacity and greater efficiency than standard wound

cartridges

■ Wide variety of materials to choose from ■ 11 different classifications of material to meet your

specific filtration needs

■ Quality Manufacturing ■ Most technically advanced string wound filter on the

market

■ Continuous wound with no seams or binders

®

Page 144

Page 146: ZenPure - Q-Test

ZenPure String Wound Filter Cartridges

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

c28 Rev 2011.07

String

Wound

Cartridges

MEDIAMICRON

RATING

NOMINAL

 DIAMETER

(INCHES)

NOMINAL LENGTH

(INCHES)CORE MATERIAL: CORE COVER END TREATMENT, CORE EXTENSIONS Gasket/ O-Ring materials

C = FDA Bleached Cotton 05 = 0.5um B = 2 1/4" 5 = 5" P = Polypropylene Blank = None Blank = None Blank = None

W = Industrial White Cotton 1 = 1.0um E = 2 3/8" 9.5 = 9 1/2" T = Tin Plated Steel N = Nylon 0 = 222 O-Ring Flat, PP E = EPDM

SW U = Natural Cotton 3 = 3.0um 9.75 = 9 3/4" S = 304 Stainless Steel P = Polypropylene 5 = 222 O-Ring Spear, PP N = Buna N

P = Polypropylene 5 = 5.0um 10 = 10" (standard) A = 316 Stainless Steel G = Fiberglass 6 = 226 O-Ring Flat, PP S = Silicon

A= FDA Polypropylene 10 = 10um P = 4 1/2" 19.5 = 19 1/2" C = Cotton 7 = 226 O-Ring Spear, PP V = Viton

F = Fibrillated Polypropylene 15 = 15um 20 = 20" 6 = 226 O-Ring Flat, PP T = TEV

R = Rayon 20 = 20um 30 = 30" F = DOE Flat Gasket, PP

Y = Polyester 25 = 25um 40 = 40" S = SOE Flat Gasket/Flat, PP

N = Nylon 30 = 30um PE =Poly Core Insert

G = Fiberglass 40 = 40um AE = 316 SS Core Insert

T = Ryton 50 = 50um EC = Extended Crimped Core

75 = 75um CC = Core Connector

100 = 100um PS = Poly Spring

125 = 125um PM = Metal Spring (poly cap)

150 = 150um ACS = Std. 316SS Cap and Spring

250 = 250um

350 = 350um

Example – String Wound FDA bleached cotton, 3um, 2 7/16" Diameter, 10", Polypropylene core - SWC3R10P

R = 2 7/16"

(standard)

Media Max Temp Applications

Bleached Cotton ( C) 300° F  For potable liquids, vegetable oils, beverages, organic solvents,

FDA 150° C water, dilute acids, petroleum oils, and other services.

Industrial White Cotton 300° F  Same (non - FDA) applications as bleached cotton.

(W) 150° C

Natural Cotton (U) 300° F  Same (non - FDA) applications as bleached cotton.

150° C

Polypropylene (P) 180° F  Filtration of organic acids, alkalies, solvents and many

82° C other chemicals. Very effective in low viscosity solutions.

FDA Polypropylene (A) 180° F  Same chemical compatibility as polypropylene, fiber complies with

82° C FDA regulation that permits contact with food and edible products.

Fibrillated 180° F  Same chemical compatibility as polypropylene. Has no finish on

Polypropylene (F) 82° C material, therefore, will not cause foaming.

Rayon ( R) 300° F  Chemical compatibility similar to cotton. Used primarily in

150° C filtration of petroleum oils.

Polyester (Y) 250° F  Chemical compatibility similar to cotton and polypropylene. Has a

121° C higher temperature resistance than polypropylene in most cases.

Nylon (N) 350° F  Used for special process applications, concentrated alkalies and

177° C hydrocarbons.

Fiberglass (G) 750° F  Filtration of organic acids, organic solvents, petroleum 399° C

399° C oils, mineral acids, and other corrosive or high-temperature services

Ryton (T) 375° F  Similar chemical compatibility to both Nylon and Fiberglass. Excellent

191° C resistance to solvents and acids except for hot sulfuric acid and

nitric acid.

String Wound Filter Cartridge Ordering Guide

Specials available upon request

Page 145

Page 147: ZenPure - Q-Test

ZenPure

This page left blank intentionally

Zen

Pu

re

Page 146

Page 148: ZenPure - Q-Test

PureFlo Mini Filter Cartridge Series Sizes and End Configuration

ZenPure

ZenPure North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

C28.9 Rev 2011.07

56

83 442

56

76 372

56

321

9212

56

93 642

56

86 472

56

421

0312

56

93 342

56

86 272

56

421

8212

56

83

852

56

76

782

56

321

3412

56

93

162

56

86 092

56

421

6412

80

56

152

80

56

082

80

56

6312

56

86 572

56

93 742

56

421 2312

701

7112

56

68( CODE-C ) ( CODE-N ) ( CODE-A ) ( CODE-E ) ( CODE-D ) ( CODE-F ) ( CODE-S ) (CODE-M)

H - 1.5”

S - 2.5”

L - 5”

015 O-Ring 116 Housing Seal

116 Inner O-Ring

118 O-Ring 1/2” MNPT Flange 116 Inner O-Ring with locking Groove

123 O-Ring with hold down tabs

Page 147

Page 149: ZenPure - Q-Test

PureFlo® Polypro Mini Membrane Filter Cartridges

ZenPure Z

en

Pu

re

PureFlo® polypropylene membrane filter cartridges are highly

retentive and naturally hydrophobic filters. Polypropylene

membrane is a reliable choice for the purification of

aggressive chemicals, compressed gases, and vent

applications. The all-polypropylene construction is an

excellent economic alternative to the more expensive

fluoropolymer based cartridges.

No adhesives, binders, or surfactants are used in the

manufacturing process. Furthermore, the all-polypropylene

construction provides excellent thermal and chemical

compatibility with low and high pH chemicals.

PureFlo polypropylene mini membrane filter cartridges are

absolute-rated to ensure consistent filter performance each and

every time out of the package. All filter cartridges are 100%

integrity tested to ensure filter performance.

Materials of Construction

Media: Polypropylene Membrane (hydrophobic)

Media Supports: Polypropylene

Cage, Core, End Caps: Polypropylene

O-Rings: Silicone, EPDM, Fluoroelastomer, Buna N

Dimensions (nominal) Lengths: 1.5in (38mm), 2.5 in (75 mm), 5 in. (135

mm)

Diameter: 2.2 in. (56 mm)

Effective Filtration Area 0.7 ft2 (650 cm2) per 1.5" cartridge

1.4 ft2 (1300 cm2) per 2.5" cartridge

2.7 ft2 (2500 cm2) per 5.0" cartridge

Operating Conditions Maximum Forward Differential Pressure:

4.1 bar (60 psid) at 68°F/20°C

2.0 bar (29 psid) at 176°F/80°C

Maximum Reverse Differential Pressure:

2.0 bar (29 psid) at 68°F/20°C

1.0 bar (14.5 psid) at 176°F/80°C

Maximum Operating Temperature: 176°F/80°C

Regulatory Compliance Manufactured from materials that conform to the

requirements of 21CFR Part 177 of the U.S. Code of

Federal Regulations and USP Class VI Biological

Test for Plastics.

Applications

Acids Ink

Bases Parts Cleaning

Solvents Pharmaceuticals

Fine Chemicals Biologics

Plating Solutions Venting

Retrofits Code 2230, 4463, 4440 & SLK

Features Benefits

■ Polypropylene Pleated Membrane Media

(Absolute Rated)

■ Consistent and reproducible particulate removal

■ High flow rates and low pressure drops

■ Superior filter lifetime and process throughputs

■ 100% Polypropylene Construction ■ Provides excellent compatibility with a wide-range of chemicals

such as acids, bases, and solvents

■ No media migration into the process fluid

■ Low Filter Extractables ■ No adhesives, binders, or surfactants are used during manufacturing

resulting in superior downstream cleanliness

■ All cartridges are rinsed with high-purity water to reduce

extractables and downtime

Sterilization & Autoclaving

The filters can be sterilized by autoclaving for up to 25 cycles

at 257°F/125°C. The filters can also be sterilized by steam-in-

place procedure up to 5 cycles at 275°F/135°C for 30 minutes

at less than 0.3 bar differential pressure. The filters can also

sanitized by hot water or common chemicals that are compati-

ble with filter components.

Page 148

Page 150: ZenPure - Q-Test

ZenPure PureFlo® Polypro Mini Membrane Filter Cartridges

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

C29 Rev 2011.08

PureFlo Polypropylene Mini Membrane Filter Cartridge Ordering Guide

0

2

4

6

8

10

0

0.08

0.16

0.24

0.32

0.4

0.48

0.56

0.64

0 0.5 1 1.5 2 2.5 3

0 2 4 6 8 10

PureFlo 1.5" PolyPro Membrane Mini

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

0.1

0.2

0

2

4

6

8

10

0

0.08

0.16

0.24

0.32

0.4

0.48

0.56

0.64

0 0.5 1 1.5 2 2.5 3

0 2 4 6 8 10

PureFlo 2.5" PolyPro Membrane Mini

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

0.1

0.2

0

2

4

6

8

10

0

0.08

0.16

0.24

0.32

0.4

0.48

0.56

0.64

0 0.5 1 1.5 2 2.5 3

0 2 4 6 8 10

PureFlo 5" PolyPro Membrane Mini

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

0.1

0.2

PureFlo Mini PP

Filter Cartridges

Removal

Rating

(Micron)

End Modifications LengthO-Ring / Gasket

MaterialsPackage Qty

MMP = Mini PP 010 = 0.1 A = 116 Internal O-Ring H = 1.5" E = EPDM 2P = 2pc/ pack (5")Membrane 020 = 0.2 C = 015 O-Ring S = 2.5" N = Buna NCartridge D = 1/2" MNPT L = 5" S = Silicone

E = 118 O-Ring V = Viton Option

F = Flange* 0 = O-Ringless Seal - 5 = SS InsertM = 123 O-Rings**N = 116 Internal Housing Seal

* - F end mondification is compatible to fit in a PALL SealKleenTM

Housing, **- M end modification is compatible to fit in a Millipore OptiSealTM Housing

Example - A 3 pack of 2.5", 0.1 micron filters with 116 internal EPDM o-ring would be MMP010ASE3P

3P = 3pc/ pack (1.5" and 2.5")

S = 116 Internal O-Ring w/Locking Groove

Flange End Modification

Page 149

Page 151: ZenPure - Q-Test

PureFlo® Polypro Mini Filter Cartridges

ZenPure Z

en

Pu

re

PureFlo® polypropylene mini filter cartridges are highly retentive

graded porosity polypropylene media filters that have been specially

designed for clarification and pre-filtration applications.

The graded porosity design removes particles in sequence by size

exclusion – larger particles by the more open outer layers and

smaller particles by the tighter inner layers. The outer layers act as a

pre-filter while the inner layers provide the absolute rating at the

specified pore size. This efficiently spreads the contaminants

throughout the media matrix resulting in superior contaminant hold-

ing capacity, lifetime, and pressure drop as compared to other media

cartridges. No adhesives, binders, or surfactants are used in the

manufacturing process. The non-woven media does not allow for

migration into the process fluid, thereby reducing the potential for

extractables and downtime. Furthermore, the all-polypropylene con-

struction provides excellent thermal and chemical compatibility with

low and high pH chemicals.

PureFlo polypropylene mini filter cartridges are absolute-rated to

ensure consistent filter performance each and every time out of the

package at 0.3, 0.6, 1, 3, 5, 7, 10, 30, 50 and 70 microns.

Applications Acids Ink Jets

Bases Beverages

Solvents Pharmaceuticals

Fine Chemicals Biologics

Plating Solutions Dyes

Process Water Parts Cleaning

Features Benefits

■ Graded Porosity Pleated

Polypropylene Media

■ Media matrix removes particles in sequence by size – larger

particles by the more open outer layers and smaller particles

by the tighter inner layers

■ High flow rates and low pressure drops

■ Superior filter lifetime and process throughputs

■ 100% Polypropylene Construction ■ Excellent thermal and chemical compatibility

■ No media migration

■ Absolute-Rated Filter Performance ■ Consistent and reproducible particulate removal

■ Low Filter Extractables ■ No adhesives, binders, or surfactants used

■ Excellent downstream cleanliness reduces start-up time

Materials of Construction Media: Graded Porosity Non-Woven Polypropylene

Media Supports: Polypropylene

Cage, Core, End Caps: Polypropylene

O-Rings: Silicone, EPDM, Fluoroelastomer, Buna N

Dimensions (nominal) Lengths: 1.5in (38mm),2.5 in (75 mm), 5 in. (135 mm)

Diameter: 2.2 in. (56 mm)

Effective Filtration Area 0.59 ft2 (550 cm2) per 1.5" cartridge

1.3 ft2 (1200 cm2) per 2.5" cartridge

2.368 ft2 (2200 cm2) per 5.0" cartridge

Operating Conditions

Maximum Forward Differential Pressure:

4.1 bar (60 psid) at 68°F/20°C

2.0 bar (29 psid) at 176°F/80°C

Maximum Reverse Differential Pressure:

2.0 bar (29 psid) at 68°F/20°C

1.0 bar (14.5 psid) at 176°F/80°C

Maximum Operating Temperature: 176°F/80°C

Sterilization & Autoclaving The filters can be sterilized by autoclaving for up to 25 cycles

at 257°F/125°C. The filters can also be sterilized by steam-in-

place procedure up to 5 cycles at 275°F/135°C for 30 minutes

at less than 0.3 bar differential pressure. The filters can also

sanitized by hot water or common chemicals that are compati-

ble with filter components. Retrofits Code 2230, 4463, 4440 & SLK

Regulatory Compliance Manufactured from materials that conform to the requirements of

21CFR Part 177 of the U.S. Code of Federal Regulations and

USP Class VI Biological test for Plastics

Page 150

Page 152: ZenPure - Q-Test

ZenPure PureFlo® Polypro Mini Filter Cartridges

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

D30 Rev 2011.08

PureFlo Polypropylene Mini Filter Cartridge Ordering Guide

0

1

2

3

4

5

6

0

0.05

0.1

0.15

0.2

0.25

0.3

0.35

0.4

0 0.5 1 1.5 2 2.5 3

0 2 4 6 8 10

PureFlo Mini PP (1.5in) Cartridge

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

0.30.6

1.0

5.0, 10

30, 50, 70

3.0

0

1

2

3

4

5

6

0

0.05

0.1

0.15

0.2

0.25

0.3

0.35

0.4

0 0.5 1 1.5 2 2.5 3

0 2 4 6 8 10

PureFlo Mini PP (2.5in) Cartridge

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

0.3

0.6

1.0

5.0, 10

30, 50, 70

3.0

Flange End Modification

0

0.5

1

1.5

2

2.5

3

0

0.05

0.1

0.15

0.2

0 0.5 1 1.5 2 2.5 3

0 2 4 6 8 10

PureFlo Mini PP (5in) Cartridge

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

0.3

0.6

1.0

5.0, 10

30, 50, 70

3.0

PureFlo Mini PP

Filter CartridgesRemoval Rating End Modifications Length

O-Ring / Gasket

MaterialsPackage Qty

003 = 0.3um A = 116 Inner O-Ring H = 1.5" E = EPDM 2P = 2pc/ pack (5")NMP = Mini PP 006 = 0.6um C = 015 O-Ring S = 2.5" N = Buna N

Cartridge 010 = 1.0um D = 1/2" MNPT L= 5" S = Silicone030 = 3.0um E = 118 O-Ring V = Viton050 = 5.0um F = Flange* 0 = O-Ringless 070 = 7.0um M = 123 O-Rings**100 = 10 um N = 116 Inner Housing Seal300 = 30 um Option

500 = 50 um - 5 = SS Insert700 = 70 um

* - F end mondification is compatible to fit in a PALL SealKleenTM

Housing, **- M end modification is compatible to fit in a Millipore OptiSealTM Housing

Example - A 3 pack of 2.5", 3 micorn filters with 116 Internal EPDM o-ring would be NMP030ASE3P

3P = 3pc/ pack (1.5" and 2.5")

S = 116 Internal O-Ring w/Locking Groove

Page 151

Page 153: ZenPure - Q-Test

PureFlo® Mini Depth Pleated PP Filters

(Depth PP Media on PP Construction)

ZenPure Z

en

Pu

re

High Contaminant Holding Filtration

PureFlo® Pleated Depth Mini-Cartridge filters are designed for filtration and clarification applications in the pharmaceutical, biotechnology, food and beverage, medical, chemical, and water indus-tries. This family of products is particularly suit-able for the fluids that contain gels, colloidal sus-pensions, or high suspended solids.

Highly retentive graded porosity design removes particles by size exclusion – larger particles by the more open outer layers and smaller particles by the tighter inner layers. The outer layers act as a pre-filter while the inner layers provide the absolute rating at the specified pore size. This efficiently spreads the contaminants throughout the media matrix, thereby, resulting in superior contaminant holding capacity, lifetime, and lower pressure drop as compared to other depth media cartridges.

Applications Clarification Ink Gel Removal Beverages Yeast Removal Pharmaceuticals Fine Chemicals Biologics Plating Solutions Wine Beer Water Specifications

Materials of Construction: Media: Non-Woven Polypropylene Media Supports: Polypropylene Cage, Core, End Caps: Polypropylene O-Rings: Silicone, EPDM, Fluoroelastomer, Buna N, Nominal Dimensions: Lengths: 1.5”, 2.5”, 5”, and 10”

Diameter: 2.2 in. (56mm)

Available Ratings: 0.5um, 1.0um, 1.5um, 2.5um, 4.5um, 10um, and 20um Operating Conditions: Maximum Forward Differential Pressure: 4.1 bar (60 psid) at 68°F/20°C

2.0 bar (29 psid) at 176°F/80°C Maximum Reverse Differential Pressure: 2.0 bar (29 psid) at 68°F/20°C 1.0 bar (14.5 psid) at 176°F/80°C Maximum Operating Temperature: 176°F/80°C

Regulatory Compliance: The filters are constructed with polypropylene resins and filtration media in

compliance with 21CFR Part 177 of the US Code of Federal Regulations and USP Class VI Biological Test for Plastic.

Page 152

Page 154: ZenPure - Q-Test

ZenPure PureFlo® Mini Pleated PP Filter Cartridges

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

D30.5 Rev 2011.08

PureFlo Mini Depth Pleated PP Filter Cartridge and Capsule Ordering Guide

0

1

2

3

4

5

6

0

0.05

0.1

0.15

0.2

0.25

0.3

0.35

0.4

0 0.5 1 1.5 2 2.5

0 2 4 6 8

PureFlo Mini Depth Pleated PP (1.5in) Cartridge

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

1.5

2.5

4.5

10

0

1

2

3

4

5

0

0.04

0.08

0.12

0.16

0.2

0.24

0.28

0.32

0 0.5 1 1.5 2 2.5 3

0 2 4 6 8 10

PureFlo Mini Depth Pleated PP (2.5in) Cartridge

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

1.5

2 5

4.510

0

0.5

1

1.5

2

2.5

3

3.5

4

0

0.05

0.1

0.15

0.2

0.25

0 1 2 3 4 5

0 4 8 12 16

PureFlo Mini Depth Pleated PP (5in) Cartridge

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

1.5

2.5

4.5

10

PureFlo Depth

Pleated Mini PP

Filter Cartridges

Removal Rating End Modifications LengthO-Ring / Gasket

MaterialsPackage Qty

002 = 0.2 micron A = 116 Inner O-Ring H = 1.5" E = EPDM 2P = 2pc/ pack (5")JDP = Mini Depth 005 = 0.5 micron C = 015 O-Ring S = 2.5" N = Buna N

Pleated PP 010 = 1.0 micron D = 1/2" MNPT L= 5" S = SiliconeCartridge 015 = 1.5 micron E = 118 O-Ring V = Viton

025 = 2.5 micron F = Flange* O = O-Ringless Seal045 = 4.5 micron M = 123 O-Rings** Option

100 = 10 micron N = 116 Inner Housing Seal - 5 = SS Insert200 = 20 micron

* - F end mondification is compatible to fit in a PALL SealKleenTM

Housing, **- M end modification is compatible to fit in a Millipore OptiSealTM Housing

Example - A 3 pack of 2.5", 2.5 micorn filters with 116 Internal EPDM o-ring would be JDP025ASE3P

3P = 3pc/ pack (1.5" and 2.5")

S = 116 Internal O-Ring w/Locking Groove

Specifications (cont.)

Sterilization & Autoclaving The filters can be sterilized by autoclaving for up to 25 cycles at 257°F/125°C. The filters can also be sterilized by steam-in-place procedure up to 5 cycles at 275°F/135°C for 30 minutes at less than 0.3 bar differential pressure. The filters can also sanitized by hot water or com-mon chemicals that are compatible with filter components.

Page 153

Page 155: ZenPure - Q-Test

PureFlo® PTFE Mini Filter Cartridge

(PTFE/PP Construction)

ZenPure Z

en

Pu

re

Specification Materials of Construction: Media: PTFE Media Supports: Polypropylene Cage, Core, End Caps: Polypropylene O-Rings: Silicon (Standard), EPDM, Buna N, TES, Fluroelastomer Sealing: Thermally welded Nominal Dimensions: Lengths: 1.5 in (38mm), 2.5 in (75 mm), 5 in. (135 mm)

Diameter: 2.2 in. (56 mm)

Effective Filtration Area: 0.70 ft2 (650 cm2) per 1.5" cartridge 1.35 ft2 (1250 cm2) per 2.5" cartridge 2.6 ft2 (2400 cm2) per 5.0" cartridge Available Ratings: 0.1um to 10um (see Ordering Guide) Operating Conditions: Maximum Forward Differential Pressure: 4.1 bar (60 psid) at 68°F/20°C

2.0 bar (29 psid) at 176°F/80°C Maximum Reverse Differential Pressure: 2.0 bar (29 psid) at 68°F/20°C 1.0 bar (14.5 psid) at 176°F/80°C Maximum Operating Temperature: 176°F/80°C

Regulatory Compliance: The filters are constructed with polypropylene resins and filtration media in compliance with 21CFR Part 177 of the U.S. Code of Federal Regulations and USP Class VI Biological Test for Plastics.

Applications

Buffers and Media Fermentation Tanks

Product Sterilization Venting

Bio Bags Pharmaceuticals

Vaccines Biologics

Gas Filtration Scale up Processing

Ink Jets Acids and Bases

Versatile Small Cartridge filter

PureFlo® PTFE mini filter cartridges are highly reten-tive, hydrophobic PTFE membrane filters that have been specially designed for critical applications. No adhesives, binders, or surfactants are used in the manufacturing process. All cartridges are rinsed with high-purity pyrogen-free water to reduce extractables and downtime.

The naturally hydrophobic PTFE membrane is ideally suited for filtering aggressive chemicals such as acids, bases, and solvents. In addition, the hydrophobic membrane provides superior flow and pressure drop characteristics per unit area for gas filtration and tank venting applications. All filter cartridges are 100% in-tegrity tested to ensure filter performance each and every time out of the package. We are currently offer-ing seven different PTFE pore sizes with eight different end modifications and three different length options to meet the needs of a wide variety of processes.

Retrofit for Mini Cartridge

Page 154

Page 156: ZenPure - Q-Test

ZenPure PureFlo® PTFE Mini Filter Cartridge

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

D31 Rev 2011.08

0

2

4

6

8

10

0

0.08

0.16

0.24

0.32

0.4

0.48

0.56

0.64

0 0.5 1 1.5 2 2.5 3

0 2 4 6 8 10

PureFlo 1.5" PTFE Cartridge

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

0.1 0.2 0.45

1.0

0

2

4

6

8

10

0

0.08

0.16

0.24

0.32

0.4

0.48

0.56

0.64

0 0.5 1 1.5 2 2.5 3

0 2 4 6 8 10

PureFlo 5.0" PTFE Cartridge

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

0.1

0.2

0.45

1.0

0

2

4

6

8

10

0

0.08

0.16

0.24

0.32

0.4

0.48

0.56

0.64

0 0.5 1 1.5 2 2.5 3

0 2 4 6 8 10

PureFlo 2.5" PTFE Cartridge

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

0.1 0.2

0.45

1.0

Flange End Modification

PureFlo PTFE Mini Filter Cartridge Ordering Guide

PureFlo Mini PTFE

Filter CartridgesRemoval Rating End Modifications Length

O-Ring / Gasket

MaterialsPackage Qty

010 - 0.10 micron A = 116 Inner O-Ring H = 1.5" E = EPDM 2P = 2pc/ pack (5")MMF 020 - 0.20 micron C = 015 O-Ring S = 2.5" N = Buna N

045 - 0.45 micron D = 1/2" MNPT L = 5" S = Silicone100 - 1.0 micron E = 118 O-Rings U = TES300 - 3.0 micron F = Flange* V = Fluro-Elastomer Option

500 - 5.0 micron M = 123 O-Rings** O = O-Ringless - 5 = SS Insert999 - 10 micron N = 116 Inner Housing Seal

Example - A 3 pack of 2.5", 0.1 micron filters with 2-015 EPDM o-ring would be MMF010CSE3P

3P = 3pc/ pack (1.5" and 2.5")

* - F end modification is compatible to fit in a PALL SealKleen TM Housing, **- M end modification is compatible to fit in a Millipore OptiSeal TM Housing

S = 116 Inner O-Ring with locking groove

Specifications (cont.)

Bacterial Retention (for 0.2um membrane): Complete retention of > 107organisms/cm2 of Brevundimonas diminuta in accordance with the current HIMA challenge methodology (ASTM F838-83). Validation Guide upon request.

Sterilization & Autoclaving

The filters can be sterilized by autoclaving for up to 25 cycles at 257°F/125°C. The filters can also be sterilized by steam-in-place procedure up to 10 cycles at 275°F/135°C for 30 minutes at less than 0.3 bar differential pres-sure. The filters can also sanitized by hot water or common chemicals that are compatible with filter components.

Bacterial Endotoxin:

Effluent is non-pyrogenic per USP Bacterial Endotoxin (0.25 EU/ml), deter-mined using Limulus Amebocyte Lysate (LAL) Test.

Page 155

Page 157: ZenPure - Q-Test

PureFlo® PTFE Mini Vent Filter Cartridge

(PTFE/PP Construction)

ZenPure Z

en

Pu

re

Applications

Buffers and Media Fermentation Tanks

Product Sterilization Venting/ Exhaust

Cell Culture Pharmaceuticals

Vaccines Biologics

Gas Filtration Sterile Air/Gas inlet

Versatile Small Cartridge filter

PureFlo® PTFE small vent filter cartridges are highly retentive, hydrophobic PTFE membrane filters that have been specially designed for criti-cal applications. The PTFE membrane in an all-polypropylene construction provides excellent chemical compatibility and superior flow per unit area as compared to other membrane cartridges. No adhesives, binders, or surfactants are used in the manufacturing process. All cartridges are rinsed with high-purity pyrogen-free water to re-duce extractables and downtime.

The naturally hydrophobic PTFE membrane is ide-ally-suited for aggressive fumes from chemicals such as acids, bases, and solvents. The hydro-phobic membrane will provides superior flow and pressure drop characteristics per unit area for gas filtration and tank venting applications. All filter cartridges are 100% integrity tested to ensure filter performance each and every time out of the package.

Specifications Materials of Construction: Media: PTFE Media Supports: Polypropylene Cage, Core, End Caps: Polypropylene O-Rings: Silicon (Standard), EPDM, Buna N, TES, Fluoroelastomer Sealing: Thermally welded Nominal Dimensions: Lengths: 2.28 in (58mm) Diameter: 1.54 in. (40 mm)

Effective Filtration Area: 0.46 ft2 (400 cm2) per cartridge Available Ratings: 0.2um Operating Conditions: Maximum Forward Differential Pressure: 4.1 bar (60 psid) at 68°F/20°C

2.0 bar (29 psid) at 176°F/80°C Maximum Reverse Differential Pressure: 2.0 bar (29 psid) at 68°F/20°C 1.0 bar (14.5 psid) at 176°F/80°C Maximum Operating Temperature: 176°F/80°C

Regulatory Compliance: The filters are constructed with polypropylene resins and filtration media in compliance with 21CFR Part 177 of the U.S. Code of Fed- eral Regulations and USP Class VI Biological Test for Plastics.

Page 156

Page 158: ZenPure - Q-Test

ZenPure PureFlo® PTFE Small Vent Filter Cartridge

ZenPure Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

D31.5 Rev 2011.08

PureFlo PTFE Small Vent Filter Cartridge Ordering Guide

Specifications (cont.)

Bacterial Retention (for 0.2um membrane): Complete retention of > 107organisms/cm2 of Brevundimonas diminuta in accordance with the current HIMA challenge methodology (ASTM F838-83). Validation Guide upon request.

Sterilization & Autoclaving The MVF Series filter can be sterilized by autoclaving for up to 25 cycles at 257°F/125°C. The MVF Series filter can also be sterilized by steam-in-place procedure up to 10 cycles at 275°F/135°C for 30 minutes at less than 0.3 bar differential pressure. The Both the MVF & MVE Series filters can also sanitized by hot water or common chemicals that are compatible with filter components.

Bacterial Endotoxin: Effluent is non-pyrogenic per USP Bacterial Endotoxin (0.25 EU/ml), determined using Limulus Amebocyte Lysate (LAL) Test

0

0.2

0.4

0.6

0.8

1

0

0.008

0.016

0.024

0.032

0.04

0.048

0.056

0.064

0 20 40 60 80 100

0 0.5 1 1.5 2 2.5 3 3.5

PureFlo PTFE Small Vent Filter

slpm

BarPSID

scfm

Diff

eren

tial

Pres

sure

Flow Rate @22°C, Nitrogen

0.2um

Filter Type and Construction

Removal

Rating

(Micron)

Adaptors O-Ring MaterialsStandard

Package Qty

E = EPDM020 = 0.2 C = 015 O-Ring N = Buna N 3P = 3pc/pack

S = SiliconeV = Fluro-Elastomer Option

- 5 = SS Insert

Note: MVF/MVE Cartridges (~400cm2 for MVF and ~300 for MVE)

MVF - PTFE with standard PP parts and PP support

MVE - PE with standard HPDE parts and PE support

Example - A 3 pack mini vent filter with PTFE 0.2 micron with 2-015 EPDM o-ring would be MVF020CE3P

Page 157

Page 159: ZenPure - Q-Test

PureFlo® PE Mini Filter Cartridge

(PE/HDPE Construction)

ZenPure Z

en

Pu

re

Specification Materials of Construction: Media: PE Media Supports: HDPE Cage, Core, End Caps: HDPE O-Rings: Silicon (Standard), EPDM, Buna N, TES, Fluoroelastomer Sealing: Thermally welded Nominal Dimensions: Lengths: 1.5 in (38mm), 2.5 in (75 mm), 5 in. (135 mm)

Diameter: 2.2 in. (56 mm)

Effective Filtration Area: 0.54 ft2 (500 cm2) per 1.5" cartridge 1.1 ft2 (1000 cm2) per 2.5" cartridge 2.0 ft2 (1900 cm2) per 5.0" cartridge Available Ratings: 0.1um to 10um (see Ordering Guide) Operating Conditions: Maximum Forward Differential Pressure: 4.1 bar (60 psid) at 68°F/20°C

2.0 bar (29 psid) at 176°F/80°C Maximum Reverse Differential Pressure: 2.0 bar (29 psid) at 68°F/20°C 1.0 bar (14.5 psid) at 176°F/80°C Maximum Operating Temperature: 158°F/70°C

Regulatory Compliance: The filters are constructed with HDPE resins and filtration media in compliance with 21CFR Part 177 of the U.S. Code of Federal Regulations and USP Class VI Biological Test for Plastics.

Applications

Buffers and Media Fermentation Tanks

Product Sterilization Venting

Bio Bags Pharmaceuticals

Vaccines Biologics

Gas Filtration Scale up Processing

Ink Jets Acids and Bases

Versatile Small Cartridge

PureFlo® PE mini filter cartridges are highly retentive, hydrophobic PE membrane filters that have been spe-cially designed for critical applications. The PE mem-brane in an HDPE construction provides excellent chemical compatibility and superior flow per unit area. No adhesives, binders, or surfactants are used in the manufacturing process. All cartridges are rinsed with high-purity pyrogen-free water to reduce extractables and downtime.

The PE membrane is ideally-suited for chemicals such as acids, bases, and solvents. In addition, the hydro-phobic membrane provides superior flow and pressure drop characteristics per unit area for gas filtration and tank venting applications. All filter cartridges are 100% integrity tested to ensure filter performance each and every time out of the package. We are cur-rently offering four different PE pore sizes with eight different end modifications and three different length options to meet the needs of a wide variety of proc-esses.

Page 158

Page 160: ZenPure - Q-Test

ZenPure PureFlo® PE Mini Filter Cartridge

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

D31.7 Rev 2011.08

Flange End Modification

PureFlo PE Mini Filter Cartridge Ordering Guide

Specifications (cont.)

Bacterial Retention (for 0.2um membrane): Complete retention of > 107organisms/cm2 of Brevundimonas diminuta in accordance with the current HIMA challenge methodology (ASTM F838-83). Validation Guide upon request.

Sanitizable:

The filters can be gamma sterilized up to 45kGy. The filters can also be chemically sanitized in situ using common sanitizing agents or hot water at 90°C for a limited time (dependent on time and temperature). Not Autoclavable.

Bacterial Endotoxin: Effluent is non-pyrogenic per USP Bacterial Endotoxin (0.25 EU/ml), determined using Limulus Amebocyte Lysate (LAL) Test.

56

83 442

56

76 372

56

321

9212

56

93 642

56

86 472

56

421

0312

56

93 342

56

86 272

56

421

8212

56

83

852

56

76

782

56

321

3412

56

93

162

56

86 092

56

421

6412

80

56

152

80

56

082

80

56

6312

56

86 572

56

93 742

56

421 2312

701

7112

56

68( CODE-C ) ( CODE-N ) ( CODE-A ) ( CODE-E ) ( CODE-D ) ( CODE-F ) ( CODE-S ) (CODE-M)

PureFlo Mini PE

Filter CartridgesRemoval Rating End Modifications Length

O-Ring / Gasket

MaterialsPackage Qty

020 = 0.20 micron A = 116 Inner O-Ring H = 1.5" E = EPDM 2P = 2pc/ pack (5")MME = Mini PE 100 = 1 micron C = 015 O-Ring S = 2.5" N = Buna N

Cartridge 150 = 1.5 micron D = 1/2" MNPT L = 5" S = Silicone250 = 2.5 micron E = 118 O-Rings U = TES

F = Flange* V = Fluro-ElastomerO = O-Ringless

N = 116 Inner Housing Seal

Example - A 3 pack of 2.5", 0.1 micorn filters with 2-116 EPDM o-ring would be MMS010ASE3P

3P = 3pc/ pack (1.5" and 2.5")

M = 123 O-Rings with hold down tabs**

S = 116 Inner O-Ring with locking groove

* - F end mondification is compatible to it in a PALL SealKleenTM

Housing, **- M end modification is compatible to it in a Millipore OptiSealTM Housing

Page 159

Page 161: ZenPure - Q-Test

PureFlo® Nylon Mini Filter Cartridges

ZenPure Z

en

Pu

re

PureFlo® nylon mini filter cartridges are highly retentive, naturally

hydrophilic nylon membrane filters that have been specially de-

signed for critical applications. The nylon membrane in an all-

polypropylene construction provides excellent chemical compatibil-

ity and superior flow per unit area as compared to other membrane

cartridges. No adhesives, binders, or surfactants are used in the

manufacturing process and all cartridges are rinsed with high-purity

water to reduce extractables and downtime.

The naturally hydrophilic nylon membrane does not require pre-

wetting with IPA and flushing with DI water, thereby eliminating a

potential source of contamination and hazardous waste. In addition,

unlike hydrophobic membrane such as PTFE, the hydrophilic mem-

brane of nylon reduces the potential for bubble formation by not de-

wetting in out gassing fluids. All filter cartridges are 100% integrity

tested to ensure filter performance each and every time out of the

package. PureFlo nylon mini filter cartridges are well-suited for criti-

cal applications where superior flow and particle removal efficiency

at 0.1, 0.2, 0.45, 0.65, and 1.0 micron is required.

Applications

Acids Ink Jets

Bases Beverages

Solvents Pharmaceuticals

Fine Chemicals Biologics

Plating Solutions Dyes

Process Water Parts Cleaning

Materials of Construction Membrane: Naturally Hydrophilic Nylon

Membrane Supports: Polypropylene

Cage, Core, End Caps: Polypropylene

O-Rings: Silicone, EPDM, Fluoroelastomer, Buna N

Dimensions (nominal) Lengths: 1.5 in (38mm),2.5 in (75 mm), 5 in. (135 mm)

Diameter: 2.2 in. (56 mm)

Effective Filtration Area 0.78 ft2 (720 cm2) per 1.5" cartridge

1.3 ft2 (1380 cm2) per 2.5" cartridge

2.6 ft2 (2600 cm2) per 5.0" cartridge

Operating Conditions Maximum Forward Differential Pressure:

4.1 bar (60 psid) at 68°F/20°C

2.0 bar (29 psid) at 176°F/80°C

Maximum Reverse Differential Pressure:

2.0 bar (29 psid) at 68°F/20°C

1.0 bar (14.5 psid) at 176°F/80°C

Maximum Operating Temperature: 158°F/70°C

Sterilization & Autoclaving

The filters can be sterilized by autoclaving for up to

25 cycles at 257°F/125°C. The filters can also be

sterilized by steam-in-place procedure up to 3 cycles

at 275°F/135°C for 30 minutes at less than 0.3 bar

differential pressure. The filters can also sanitized by

hot water or common chemicals that are compatible

with filter components.

Features Benefits

■ Naturally Hydrophilic Nylon Membrane

(Absolute Rated)

■ IPA pre-wetting not required – thereby eliminating a potential

source of contamination and disposal waste

■ Reduces downtime and improves throughput

■ Economic alternative to PTFE and PVDF filters

■ No de-wetting in out gassing fluids

■ Wide Chemical & Thermal

Compatibility

■ Provides excellent compatibility with a wide range of

chemicals

■ Low Filter Extractables ■ No adhesives, binders, or surfactants are used during manufac-

turing resulting in superior downstream cleanliness

Retrofits Code 2230, 4463, 4440 & SLK

Regulatory Compliance Manufactured from materials that conform to the requirements of

21CFR Part 177 of the U.S. Code of Federal Regulations and

USP Class VI Biological test for Plastic

Page 160

Page 162: ZenPure - Q-Test

ZenPure PureFlo® Nylon Mini Filter Cartridges

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

D32 Rev 2011.08

PureFlo Nylon Mini Filter Cartridge Ordering Guide

PureFlo Mini

Nylon Filter

Cartridges

Removal Rating End Modifications LengthO-Ring / Gasket

MaterialsPackage Qty

010 = 0.10 micron A = 116 Inner O-Ring H = 1.5" E = EPDM 2P = 2pc/ pack (5")MMN = Mini Nylon 020 = 0.20 micron C = 015 O-Ring S = 2.5" N = Buna N

Cartridge 050 = 0.45 micron D = 1/2" MNPT L = 5" S = Silicone065 = 0.65 micron E = 118 O-Ring V = Fluro-Elastomer Option

100 = 1.0 micron F = Flange* 0 = O-Ringless Seal - 5 = SS InsertM = 123 O-Rings**N = 116 Inner Housing Seal

* - F end mondification is compatible to fit in a PALL SealKleenTM

Housing, **- M end modification is compatible to fit in a Millipore OptiSealTM Housing

Example - A 3 pack of 2.5", 0.1 micorn filters with 2-015 EPDM o-ring would be MMN010CSE3P

3P = 3pc/ pack (1.5" and 2.5")

S = 116 Inner O-Ring with locking groove

0

2

4

6

8

10

0

0.08

0.16

0.24

0.32

0.4

0.48

0.56

0.64

0 0.5 1 1.5 2

0 1 2 3 4 5 6 7

PureFlo Mini Nylon (5") Cartridge

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

0.10.2

0.45

0.65

1.0

0

2

4

6

8

10

0

0.08

0.16

0.24

0.32

0.4

0.48

0.56

0.64

0 0.5 1 1.5 2

0 1 2 3 4 5 6 7

PureFlo Mini Nylon (1.5") Cartridge

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

0.1

0.2

0.45

0.65

1.0

0

2

4

6

8

10

0

0.08

0.16

0.24

0.32

0.4

0.48

0.56

0.64

0 0.5 1 1.5 2

0 1 2 3 4 5 6 7

PureFlo Mini Nylon (2.5") Cartridge

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

0.1

0.20.45

0.65

1.0

Flange End Modification

Page 161

Page 163: ZenPure - Q-Test

PureFlo® Charged Nylon Mini Filter Cartridge

(Charged Nylon/PP Construction)

ZenPure Z

en

Pu

re

Specification Materials of Construction: Media: Charged Nylon 6,6 membrane (hydrophilic) Media Supports: Polypropylene Cage, Core, End Caps: Polypropylene O-Rings: Silicon (Standard), EPDM, Buna N, TES, Fluoroelastomer Sealing: Thermally welded Nominal Dimensions: Lengths: 1.5 in (38mm), 2.5 in (75 mm), 5 in. (135 mm)

Diameter: 2.2 in. (56 mm)

Effective Filtration Area: 0.77 ft2 (720 cm2) per 1.5" cartridge 1.48 ft2 (1380 cm2) per 2.5" cartridge 2.80 ft2 (2600 cm2) per 5.0" cartridge Available Ratings: 0.1um, 0.2um, 0.45um, 0.65um and 1.0um Operating Conditions: Maximum Forward Differential Pressure: 4.1 bar (60 psid) at 68°F/20°C

2.0 bar (29 psid) at 176°F/80°C Maximum Reverse Differential Pressure: 2.0 bar (29 psid) at 68°F/20°C 1.0 bar (14.5 psid) at 176°F/80° C Maximum Operating Temperature: 176°F/80°C

Regulatory Compliance: The filters are constructed with polypropylene resins and filtration media in compliance with USP Class VI Biological Test for Plastics.

Retrofits Code 2230, 4463, 4440 & SLK

High Contaminant Removal

PureFlo® Charged Nylon cartridge filters are designed to remove particles smaller that its rated pore size with the power of electrical attraction (adsorption/adhesion). Many particles in water and other liquids have a negative charge that can be captured by at-traction to a positively charged filter. This combined with particle size exclusion (sieving) process and im-paction/ interception particle capture mechanism make this charged nylon filter extremely efficient. The PureFlo® Charged Nylon cartridges are naturally hydrophilic nylon membrane filters with a polyester support layer for added wetability of the membrane. The nylon membrane in an all-polypropylene construction provides excellent chemi-cal compatibility and superior flow per unit area as compared to other membrane cartridges. No adhe-sives, binders, or surfactants are used in the manu-facturing process and all cartridges are rinsed with high-purity water to reduce extractables and down-time. All filter cartridges are 100% integrity tested to ensure filter performance each and every time out of the package.

Applications

DI Water UltraPure Water Critical Parts Cleaning

Endotoxin Reduction

Fine Chemicals Plating Solutions

Page 162

Page 164: ZenPure - Q-Test

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas : ZenPure Americas, Inc. www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

ZenPure

D32.5 Rev 2011.08

PureFlo® Charged Nylon Mini Filter Cartridge

Flange End Modification

PureFlo Mini

CartridgesRemoval Rating End Modifications Length

O-Ring / Gasket

MaterialsPackage Qty

010 = 0.10 micron A = 116 Inner O-Ring H = 1.5" E = EPDM 2P = 2pc/ pack (5")020 = 0.20 micron C = 015 O-Ring S = 2.5" N = Buna N050 = 0.45 micron D = 1/2" MNPT L = 5" S = Silicone065 = 0.65 micron E = 118 O-Ring V = Fluro-Elastomer Option

100 = 1.0 micron F = Flange* 0 = O-Ringless Seal - 5 = SS InsertM = 123 O-Rings**N = 116 Inner Housing Seal

EMN = Mini Charged Nylon

Cartridge

3P = 3pc/ pack (1.5" and 2.5")

Example - A 3 pack of 2.5", 0.1 micorn filters with 2-015 EPDM o-ring would be EMN010CSE3P

* - F end mondification is compatible to it in a PALL SealKleenTM

Housing, **- M end modification is compatible to fit in a Millipore OptiSealTM Housing

S = 116 Inner O-Ring with locking groove

PureFlo Mini Filter Cartridge Series Sizes

and End Configuration

56

83 4

42

56

76 37

2

56

32

1

92

12

56

93 64

2

56

86 4

72

56

42

1

5.

13

12

56

93

5.

34

2

56

86 3

72

56

42

1

5.

82

12

56

83

85

2

56

76

78

2

56

32

1

34

12

56

93

51

62

56

86

5.

09

2

56

42

1

5.

64

12

80

56

15

2

80

56

08

2

80

56

63

12

015 O-Ring

H Size (1.5")

S Size (2.5")

L Size(5")

116 Housing Seal

116 Inner O-Ring

118 O-Ring 1/2”MNPT Flange

PureFlo Charged Nylon Mini Filter Cartridge Ordering Guide

Specifications (cont.)

Sterilization & Autoclaving The filters can be sterilized by autoclaving for up to 25 cycles at 257°F/125°C. The filters can also be sterilized by steam-in-place procedure up to 3 cycles at 275°F/135°C for 30 minutes at less than 0.3 bar differential pressure. The filters can also sanitized by hot water or com-mon chemicals that are compatible with filter components.

Page 163

Page 165: ZenPure - Q-Test

PureFlo® PES Mini Filter Cartridges

ZenPure Z

en

Pu

re

PureFlo® PES mini filter cartridges are highly-retentive hydro-

philic PES membrane filters that have been specially designed for

critical applications. The PES membrane in an all-polypropylene

construction provides excellent chemical compatibility and superior

flow per unit area as compared to other membrane cartridges. No

adhesives, binders or surfactants are used in the manufacturing

process. All cartridges are rinsed with high-purity water to reduce

extractables and downtime.

The hydrophilic PES membrane does not require prewetting with

IPA and flushing with DI water, thereby eliminating a potential

source of contamination and hazardous waste. In addition, unlike

hydrophobic filters such as PTFE, hydrophilic membrane reduces the

potential for bubble formation by not dewetting in outgassing fluids.

All filter cartridges are 100% integrity tested to ensure filter perform-

ance each and every time out of the package. PureFlo PES mini filter

cartridges are well-suited for critical applications where superior

flow and particle removal efficiency at 0.04, 0.1, 0.2, 0.45, 0.65, 0.80

and 1.2 micron is required.

Applications

Acids Ink Jets

Bases Beverages

Solvents Pharmaceuticals

Fine Chemicals Biologics

Plating Solutions Dyes

Process Water Lacquers

Materials of Construction Membrane: Hydrophilic Polyethersulfone

Membrane Supports: Polypropylene

Cage, Core, End Caps: Polypropylene

O-Rings: Silicone, EPDM, Fluoroelastomer, Buna N

Dimensions (nominal) Lengths: 1.5in (38mm), 2.5 in (75 mm), 5 in. (135 mm)

Diameter: 2.2 in. (56 mm)

Effective Filtration Area 0.78 ft2 (720 cm2) per 1.5" cartridge

1.5 ft2 (1380 cm2) per 2.5" cartridge

2.8 ft2 (2600 cm2) per 5.0" cartridge

Operating Conditions Maximum Forward Differential Pressure:

4.1 bar (60 psid) at 68°F/20°C

2.0 bar (29 psid) at 176°F/80°C

Maximum Reverse Differential Pressure:

2.0 bar (29 psid) at 68°F/20°C

1.0 bar (14.5 psid) at 176°F/80°C

Maximum Operating Temperature: 176°F/80°C

Sterilization & Autoclaving The filters can be sterilized by autoclaving for up to 25

cycles at 257°F/125°C. The filters can also be sterilized by

steam-in-place procedure up to 10 cycles at 275°F/135°C

for 30 minutes at less than 0.3 bar differential pressure.

The filters can also sanitized by hot water or common

chemicals that are compatible with filter components.

Features Benefits

■ Hydrophilic PES Membrane ■ IPA pre-wetting not required – thereby eliminating a potential

source of contamination and disposal waste

■ Reduces downtime and improves throughput

■ Economic alternative to PTFE filters

■ No dewetting in outgassing fluids, unlike hydrophobic filters

such as PTFE

■ Wide Chemical & Thermal Compatibility ■ Provides excellent compatibility with a wide-range of

chemicals

■ Low Filter Extractables ■ No adhesives, binders, or surfactants are used during

manufacturing resulting in superior downstream cleanliness

■ All cartridges are rinsed with high-purity water

Retrofits Code 2230, 4463, 4440 & SLK

Regulatory Compliance Manufactured from materials that conform to the requirements of

21CFR Part 177 of the U.S. Code of Federal Regulations and USP

Class VI Biological Test for Plastics

Page 164

Page 166: ZenPure - Q-Test

ZenPure PureFlo® PES Mini Filter Cartridges

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

D33 Rev 2011.08

PureFlo PES Filter Cartridge Ordering Guide

PureFlo Mini PES

Filter CartridgesRemoval Rating End Modifications Length

O-Ring / Gasket

MaterialsPackage Qty Grade

004 = 0.04 micron A = 116 Inner O-Ring H = 1.5" E = EPDM 2P = 2pc/ pack (5") Blank = Standard

MMS = Mini PES 010 = 0.10 micron C = 015 O-Ring S = 2.5" N = Buna N - PH = Pharm grade

Cartridge 020 = 0.20 micron D = 1/2" MNPT L = 5" S = Silicone050 = 0.45 micron E = 118 O-Rings V = Fluro-elastomer065 = 0.65 micron F = Flange* 0 = O-ringless Seal Option

080 = 0.8 micron N = 116 Inner Housing Seal - 5 = SS Insert120 = 1.2 micron M = 123 O-Rings with hold

down tabs**

* - F end mondification is compatible to it in a PALL SealKleenTM

Housing, **- M end modification is compatible to it in a Millipore OptiSealTM Housing

Example - A 3 pack of 2.5", 0.1 micorn filters with 2-116 EPDM o-ring would be MMS010ASE3P

3P = 3pc/ pack (1.5" and 2.5")

S = 116 Inner O-Ring with locking groove

0

5

10

15

0

0.2

0.4

0.6

0.8

1

0 0.5 1 1.5 2 2.5 3

0 2 4 6 8 10

PureFlo Mini PES (1.5" - H) Cartridge

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

0.65

0.04

0.1

0.2

0.45

1.20.8

0

2

4

6

8

10

0

0.08

0.16

0.24

0.32

0.4

0.48

0.56

0.64

0 0.5 1 1.5 2 2.5 3 3.5 4

0 5 10 15

PureFlo Mini PES (2.5" - S) Cartridge

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

0.65

0.04

0.1

0.2

0.45

1.20.8

0

2

4

6

8

10

0

0.08

0.16

0.24

0.32

0.4

0.48

0.56

0.64

0 0.5 1 1.5 2 2.5 3 3.5 4

0 5 10 15

PureFlo Mini PES (5" - L) Cartridge

GPM

BarPSID

LPM

Dif

fere

nti

al

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

0.65

0.04

0.1

0.2

0.45

1.20.8

Flange End Modification

Page 165

Page 167: ZenPure - Q-Test

PureFlo® Glass Microfiber Mini Filter Cartridge

(Glass Fiber/PP Construction)

ZenPure Z

en

Pu

re

Specifications

Materials of Construction: Media: Borosilicate Glass Microfiber Media Supports: Polypropylene Cage, Core, End Caps: Polypropylene O-Rings: Silicon (Standard), EPDM, Buna N, TES, Fluoroelastomer Sealing: Thermally welded Nominal Dimensions: Lengths: 1.5 in (38mm), 2.5 in (75 mm), 5 in. (135 mm)

Diameter: 2.2 in. (56 mm)

Effective Filtration Area: 0.48 ft2 (450 cm2) per 1.5" cartridge 0.70 ft2 (950 cm2) per 2.5" cartridge 1.83 ft2 (1700 cm2) per 5.0" cartridge Available Ratings: 0.45um to 30um (see Ordering Guide) Operating Conditions: Maximum Forward Differential Pressure: 4.1 bar (60 psid) at 68°F/20°C

2.0 bar (29 psid) at 176°F/80°C Maximum Reverse Differential Pressure: 2.0 bar (29 psid) at 68°F/20°C 1.0 bar (14.5 psid) at 176°F/80°C Maximum Operating Temperature: 176°F/80°C

Regulatory Compliance: The filters are constructed with polypropylene resins and filtration media in

compliance with USP Class VI Biological Test for Plastics.

Applications

Buffers and Media Fermentation clarification

Cell Harvesting Venting

Pre-Filtration Pharmaceuticals

Vaccines Biologics

Gas Filtration Scale up Processing

Ink Jets Acids and Bases

Versatile Small Cartridge Filter

PureFlo® Glass Microfiber mini filter cartridges are highly retentive filters that have been specially designed for critical high loading applications. The filter is made using a borosilicate microfiber in an all-polypropylene construction that provides excellent chemical compati-bility. The filter is designed for superior flow per surface area as compared to other cartridges. No adhesives, binders or surfactants are used in the filter manufactur-ing process. The borosilicate microfiber is a non-fiber releasing media.

The PureFlo® Glass Microfiber mini cartridge is ideally-suited for microbial reduction. In addition to the high loading capacity, they have low pressure drop charac-teristics for liquid and gas filtration applications. These microfiber mini filter cartridges are well-suited for applications where deformable and non-deformable particle removals are required.

We are currently offering eight different media sizes with five different end adaptors and three different length options to meet the needs of a wide variety of processes. The Glass fiber media can also be added as a pre-filter layer to membrane filter in a cartridge or cap-sule.

Retrofits Code 2230, 4463, 4440 & SLK

Page 166

Page 168: ZenPure - Q-Test

ZenPure PureFlo® Glass Microfiber Mini Filter Cartridge

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

D34 Rev 2011.08

Flange End Modification

Specifications (cont.)

Sterilization & Autoclaving The filters can be sterilized by autoclaving for up to 25 cycles at 257°F/125°C. The filters can also be sterilized by steam-in-place procedure up to 10 cycles at 275°F/135°C for 30 minutes at less than 0.3 bar differential pressure. The filters can also sanitized by hot water or com-mon chemicals that are compatible with filter components.

PureFlo Glass Microfiber Mini Filter Cartridge Ordering Guide

PureFlo Mini

Glass Microfiber

Filter Cartridges

Removal Rating End Modifications LengthO-Ring / Gasket

MaterialsPackage Qty

005 = 0.5um A = 116 Inner O-Ring H = 1.5" E = EPDM 2P = 2pc/ pack (5")NMG = Mini Glass 010 = 1.0um C = 015 O-Ring S = 2.5" N = Buna N

Microfiber 030 = 3.0um D = 1/2" MNPT L= 5" S = Silicone

Cartridge 050 = 5.0um E = 118 O-Ring V = Viton

100 = 10 um F = Flange* 0 = O-Ringless Seal Option

200 = 20 um - 5 = SS Insert300 = 30 um

N = 116 Inner Housing Seal

M = 123 O-Rings with hold down tabs**

* - F end mondification is compatible to fit in a PALL SealKleenTM

Housing, **- M end modification is compatible to fit in a Millipore OptiSealTM Housing

3P = 3pc/ pack (1.5" and 2.5")

Example - A 3 pack of 2.5", 3 micorn filters with 116 Internal EPDM o-ring would be NMG030ASE3P

S = 116 Inner O-Ring with locking groove

56

83 442

56

76 372

56

321

9212

56

93 642

56

86 472

56

421

0312

56

93 342

56

86 272

56

421

8212

56

83

852

56

76

782

56

321

3412

56

93

162

56

86 092

56

421

6412

80

56

152

80

56

082

80

56

6312

56

86 572

56

93 742

56

421 2312

701

7112

56

68( CODE-C ) ( CODE-N ) ( CODE-A ) ( CODE-E ) ( CODE-D ) ( CODE-F ) ( CODE-S ) (CODE-M)

Page 167

Page 169: ZenPure - Q-Test

MAXX Series Pleateed Filter Elements

for Bag Filter Housings

ZenPure Z

en

Pu

re

®

The MAXX series of pleated filter elements is to be the next

generation of filter elements for bag filter housings. This

product introduction offers the most comprehensive product

offerings of inside-out flow elements available. MAXX ele-

ments combine the proven ease of use and exceptional sol-

ids loading capacity of bag filtration, with the high effi-

ciency performance characteristics of cartridge filtration.

All this results in the most versatile, reliable, and economi-

cal filter in the marketplace today.

The MAXX series of filter elements come in five different

filter media type to meet your high flow, high loading appli-

cations.

MAXX filters multiplies the area of filtration that is possible

to get in a #1 or #2 size bag filter housings. The filters allow

you to utilize your existing bag filtration equipment to proc-

ess more fluid at a lower pressure drop, thus saving you the

time and expense to upgrade the capital equipment.

Polypropylene Micro-Fiber—PMF

Borosilicate Micro fiberglass—BMF

Polypropylene Felt—PPF

Polyester Felt—PEF

Phenolic Treated Polyester—PTP

Features Benefits

■ Absolute-Rated

■ Provides reliable pore size control resulting in repeatable

filtration performance

■ Thermally bonded construction, eliminating bypass

■ Non-Fiber Releasing ■ Minimal extractables and particle release from filter, pro-

viding a high purity filtrate

■ Quality Media ■ Low pressure drop yields higher flow and reduced

processing time

■ Non-Calandard Micro-Glass matrix offering greater

service life, reducing operating costs per cartridge

Applications

Industrial Membrane Prefiltration

Coatings Lubricating Oils

Food and Beverage Beer & Wine

Chemical Processing Photographic

Pharmaceuticals R.O. Prefiltration

Page 168

Page 170: ZenPure - Q-Test

MAXX Series Pleateed Filter Elements

for Bag Filter Housings

ZenPure Z

en

Pu

re

®

MAXX Polypropylene Micro Fiber Ordering Guide

MAXX Polypropylene Micro

Fiber CartridgesRemoval Rating Length Oring Configuration O-Ring Materials Grade

005 = 0.5 micron P1 = Size 1 D1 = Single 261 oring E = EPDM Blank = Industrial

PMF 01 = 1.0 micron P2 = Size 2 D2 = Double 261 oring N = Buna N (standard) -1 = Beverage/FDA grade

03 = 3.0 micron V = Viton

05 = 5.0 micron T = TEV

10 = 10.0 micron

25 = 25.0 micron

50 = 50.0 micron

Example - MAXX Polypropylene, 1.0 micron, size #1, with single 261 Buna N o-ring, industrial grade would be PMF01P1D1N

Regulatory Compliance

Manufactured from materials that conform to the require-

ments of 21CFR Part 177 of the U.S. Code of Federal

Regulations and USP Class VI Biological Test for Food

and Beverage

Materials of Construction

Media: Polypropylene Micro-Fiber

Media Supports: Polypropylene

Cage, Core, End Caps: Polypropylene

O-Rings: EPDM, Buna N, Viton, and TEV

Sealing: Thermal Bond

Dimensions (nominal)

Lengths: Size 1 (14”), Size 2 (28”)

Diameter: 7 in. (178cm)

Effective Filtration Area

Size 1 = 24 ft2

Size 2 = 50 ft2

Operating Conditions

Maximum Forward Differential Pressure:

- Polypropylene support:

6.3 bar (90PSID) at 24°C (75°F)

Maximum Operating Temperature:

- Polypropylene support: 93°C

MAXX Polypropylene Micro Fiber (PMF) filters are en-

gineered for critical high-purity applications by optimiz-

ing the media while maintaining absolute rated perform-

ance that is both predictable and repeatable. Our unique

filter media is constructed on the latest continuous Mi-

cro−Fiber manufacturing equipment, accurately control-

ling fiber diameter and web integrity. This state-of-the-art

manufacturing method utilizes online monitoring equip-

ment that delivers the industry’s most uniform and consis-

tent media, resulting in unparalleled product consistency.

By combining this high performance media in a MAXX

PMF filter element, we have created the ultimate filter ele-

ment. This element combines the advantages of typical

bag filtration, ease of use and exceptional dirt holding ca-

pacity with the high efficiency and performance character-

istics of cartridge filtration. The inside-out flow design

ensures that unwanted contaminates stay inside the ele-

ment during change-out unlike typical cartridge filtration.

This virtually eliminates the possibility of downstream

contamination.

Our 100% polypropylene construction provides an excel-

lent range of chemical compatibility for your most de-

manding applications.

D35.1 Rev. 2011.08

Page 169

Page 171: ZenPure - Q-Test

MAXX Series Pleateed Filter Elements

for Bag Filter Housings

ZenPure Z

en

Pu

re MAXX Borosilicate Micro Fiberglass Ordering Guide

MAXX Borosillicate

MicroFiber CartridgesRemoval Rating Length Cage Design Oring Configuration O-Ring Materials Grade

005 = 0.5 micron P1 = Size 1 (14") B = Resin Bonded Felt D1 = Single 261 oring E = EPDM Blank = Industrial

BMF 01 = 1.0 micron P2 = Size 2 (26") C = Plastic PP D2 = Double 261 oring N = Buna N (standard) 1 = Bev erage/FDA grade

02 = 3.0 micron P2L = Size 2 (30") P = Ov er-the-top Sty le V = Fluorocarbon

03 = 3.0 micron T = TEV

06 = 6.0 micron S = Silicon

10 = 10.0 micron

15 = 15.0 micron

Ex ample - MAXX Borosillicate Micro iberglass, 1.0 micron, size #1, w ith single 261 Buna N o-ring, industrial grade w ould be BMF01P1D1N

Materials of Construction

Media: Borosilicate Micro fiberglass

Media Supports: Polyester

Cage, Core, End Caps: Polypropylene

O-Rings: EPDM, Buna N, Viton, and TEV

Sealing: Thermal Bond

Dimensions (nominal)

Lengths: Size 1 (14”), Size 2 (28”)

Diameter: 7 in. (178cm)

Effective Filtration Area

P1 Size = 24 ft2

P2 Size = 50 ft2

P2L Size = 55 ft2

Operating Conditions

Maximum Forward Differential Pressure:

- Polyester support:

4.8bar(70PSID) at 24°C(75°F)

Maximum Operating Temperature:

- Polyester support: 60°C

MAXX Borosilicate Micro Fiberglass (BMF) filter ele-

ments are engineered for critical high-purity applications

optimizing throughput while maintaining an absolute rated

performance that is consistent and reliable. Our micro-

glass filter elements features a media structure with high

surface area and increased void volume. The media also

has an optimized pore size geometry to minimize pressure

drop. Precision media manufacturing of fine fibers results

in a highly uniform matrix that optimizes element service

life. This advanced fine fiber technology outperforms all

competing micro−fiber technologies.

MAXX pleat design coupled with the micro-fiber offers

greater surface area, ensuring longer service life thus re-

duce operating cost. The media is non-fiber releasing

with minimal extractables providing high-purity for these

absolute-rated elements. The cartridges are thermally

bonded eliminating any chance of bypass.

MAXX BMF cartridges are the preferred choice for filter-

ing beverages such as beer and wine because they do not

remove flavor enhancing proteins.

Regulatory Compliance

Manufactured from materials that conform to the

requirements of 21CFR of the U.S. Code of Federal

Regulations and USP Class VI Biological test for

Food and Beverage

®

D35.2 Rev. 2011.08

Page 170

Page 172: ZenPure - Q-Test

MAXX Series Pleateed Filter Elements

for Bag Filter Housings

ZenPure Z

en

Pu

re

®

MAXX Polypropylene and Polyester Felt Ordering Guide

MAXX Polypropylene and

Polyester Felt CartridgesRemoval Rating Length Oring Configuration O-Ring Materials Grade

01 = 1.0 micron P1 = Size 1 D1 = Single 261 oring E = EPDM Blank = Industrial

PPF = Polypropylene Felt 05 = 5.0 micron P2 = Size 2 D2 = Double 261 oring N = Buna N (standard)

PEF = Polyester Felt 10 = 10.0 micron V = Viton

25 = 25.0 micron T = TEV

50 = 50.0 micron

75 = 75.0 micron

100 = 100.0 micron

200 = 200.0 micron

Example - MAXX Polyester Felt, 1.0 micron, size #1, with single 261 Buna N o-ring, industrial grade would be PEF01P1D1N

Materials of Construction

Media: Polypropylene, Polyester

Cage, Core, End Caps: Polypropylene

O-Rings: EPDM, Buna N, Viton, and TEV

Sealing: Thermal Bond

Dimensions (nominal)

Lengths: Size 1 (14”), Size 2 (28”)

Diameter: 7 in. (178cm)

Effective Filtration Area

Size 1 = 10 ft2

Size 2 = 20 ft2

Operating Conditions

Maximum Forward Differential Pressure:

- Polypropylene:

6.3 bar(90PSID) at 24°C(75°F)

- Polyester:

4.8bar(70PSID) at 24°C(75°F)

Maximum Operating Temperature:

- Polypropylene support: 93°C

- Polyester: 60°C

MAXX Polypropylene and Polyester Felt (PPF and PEF)

Elements feature the proven benefits of small fiber di-

ameter and a high void area, creating the perfect depth

filters. Available in either polypropylene or polyester,

these elements offer five to ten times more surface area,

depending upon the chosen configuration and materials

of construction. Coupled with your choice of single or

double o-ring seals, the result is the most reliable, and

most versatile filters available.

The increased surface area offers higher flow capacity in

existing applications. This boosts production without

investing in capital equipment. The filters have dual den-

sity with a built in pre-filter which prevents premature

blinding of the final filter media. The pleats are held

open with an internal pleat separator to enssure full utili-

zation of the entire pleat surface area.

D35.3 Rev. 2011.08 Page 171

Page 173: ZenPure - Q-Test

ZenPure MAXX Series Pleateed Filter Elements

for Bag Filter Housings

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

D35.4 Rev. 2011.08

MAXX Phenolic Treated

Polyester CartridgesRemoval Rating Length Oring Configuration O-Ring Materials Grade

01 = 1um Nom /5um Abs. P1 = Size 1 D1 = Single 261 oring E = EPDM Blank = Industrial

PTP = Polypropylene Felt 05 = 5um Nom /10um Abs. P2 = Size 2 D2 = Double 261 oring N = Buna N (standard)

10 = 10um Nom./25um Abs. V = Viton

25 = 25um Nom./50um Abs. T = TEV

50 = 50um Nom./75um Abs.

75 = 75um Nom./100um Abs.

100 = 100um Nom./200um Abs.

200 = 200um Nom./200um Abs.

Example - MAXX Phenolic Treated Polyester, 1.0 micron, size #1, with single 261 Buna N o-ring, industrial grade would be PTP01P1D1N

Materials of Construction

Media: Phenolic Treated Polyester

Cage, Core, End Caps: Polypropylene

O-Rings: EPDM, Buna N, Viton, and TEV

Sealing: Thermal Bond

Dimensions (nominal)

Lengths: Size 1 (14”), Size 2 (28”)

Diameter: 7 in. (178cm)

Effective Filtration Area

Size 1 = 10 ft2

Size 2 = 20 ft2

MAXX Phenolic Treated Polyester (PTP) combines the

advantages of resin bonded cartridges and enhanced

depth filtration with the proven inside-out flow advan-

tages of bag filtration. This makes the MAXX PTP fil-

ter the optimum alternative to cartridge filtration. The

MAXX PTP utilizes a phenolic treated polyester with

gradient density fiber material in a pleat design to cre-

ate the non-compressible media filter. Our unique pat-

ent-protected textile provides unsurpassed gel and par-

ticle removal due to maximized surface area and the

true depth design.

There is no fiber migration due to the utilization of pro-

prietary textile which has lengthy heat set fibers. This

eliminates post-filter fiber migration, which could re-

sults in compromised product and a need to re-filter.

The gradient density design, prevents premature blind-

ing of final filtration layer. Thermally-bonded end caps

eliminate bypass

The increased surface area in these pleated elements

means longer filter life and reduced disposal cost.

Longer filter life reduces labor time associated with

change-outs. This allows for higher productivity due to

longer run times. One size #1 element can replaces 40

10" equivalent resin bonded cartridges.

Phenolic Treaded Polyester Cartridge Ordering Guide

Page 172

Page 174: ZenPure - Q-Test

ZenPure

This page left blank intentionally

Zen

Pu

re

Page 173

Page 175: ZenPure - Q-Test

Hi-Pro Micro Felt Bag Filters

ZenPure Z

en

Pu

re

®

Hi-Pro micro felt bag filters provide a full range of absolute

rated filtration media to meet your exacting needs. All four

editions of the Hi-Pro Micro (HPM) line incorporate a

unique graduated layering of media, starting with a built-in

pre-filter inner layer and progressing to the tighter outer lay-

ers. The smaller particles are systematically removed as

fluid travels through multiple layers with each individual

layer performing a special function. This graduation aids in

the prevention of premature blinding which causes unneces-

sary filter change out.

The product line offerings include the Hi-Pro Micro 9200,

Hi-Pro Micro 9500, and the ultimate in bag filtration the Hi-

Pro Micro 9700 and 9900. The unrivaled Hi-Pro Micro line

is the product suggested by US EPA for the most effective

removal of Giardia and other zooflagellates. The product

has the lowest standard deviation of any other filter, which

means users achieve more consistent results from batch to

batch. Equally important, this product presents the ultimate

value in high-purity filtration.

Materials of Construction

Polypropylene Felt

Bag Sizes

1, 2, and other upon request.

Micron Sizes

1,3.5, 5, 10, 25 microns

Finish

Plain

Ring/ Flange option

Stainless Steel

Operating Conditions

Max differential pressure: 25 psid (5 Bar)

Max Operating Temperature:

Polypropylene Felt : 200ºF (93ºC)

Features Benefits ■ Three dimensional construction ■ Alternative for high particle level fluids

■ Longer life bag filter with greater flow rates

■ Low density and high permeability

■ Wide chemical & thermal compatibility ■ Provides excellent compatibility with a wide range of

chemicals such as acids, bases and solvents

■ High quality products for almost every application

■ Complete line of bag filters ■ Wide selection of filtration media

■ Provides the most complete range of standard liquid filter

bags

■ Quality manufacturing ■ Consistent and reproducible particle removal

Page 174

Page 176: ZenPure - Q-Test

ZenPure Hi-Pro Micro Felt Bag Filters

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

D35.5 Rev. 2011.07

Applications

Acids Ink Jets

Adhesives Electroplating

Alcohols Esters

Amines Greases and Oils

Beverages Electronics

Solvents Parts Cleaning

Coating Products Inks

Fine Chemicals Lacquers

Water Machinery Cooling

Paints Resins

Plating Solutions Dyes

Hi-Pro Micro Felt Bag Filter Ordering Guide

Hi-Pro Micro Felt bag filters are designed to re-

move heavy contamination in liquid fluid paths.

These filters offer a perfect replacement for your

particular application. Felt bag filters are offered

in a large range of micron sizes. Filters can also

be customized to meet your specific needs.

Material Efficiency Micron Size Bag Size Ring

99 A =1.0 1 = 7" x 16" SS = Stainless Steel

97 B =3.5 2 = 7" x 30.5

95 C =5.0

92 D =10

E =25

HPM = Hi-Pro Micro

Hi-ProMicro Felt Bag Filters

Example - a Hi Pro Micro Felt bag, 95%, 10um, size #2, with SS Ring would be HPM95D2SS

Page 175

Page 177: ZenPure - Q-Test

Felt Bag Filters

ZenPure Z

en

Pu

re

®

Felt bag filters fit a wide variety of applications and bag filter

housings. The material’s three dimensional construction cre-

ates a fabric with low density and high permeability. These

features offer longer life bags with greater flow rates and in-

creased dirt-holding capacity. Felt provides depth for greater

particle retention and generally the best cost per gallon filter

bag on the market. Felt is a versatile fabric available in several

materials and numerous micron ratings.

Bag filters are designed to remove heavy contamination in

liquid fluid paths. These filters offer a perfect replacement for

your particular application. Felt bag filters are offered in a

large range of micron sizes. Filters can also be customized to

meet your specific needs.

Materials of Construction

Polyester Felt Polypropylene Felt

Viscose Felt Nylon Felt

Nomex Felt Teflon Felt

Bag Sizes

1, 2, 3, 4, 7, 8, 9, 12, 30, 65, PH2,

RP2, and other upon request.

Micron Sizes

0.5 to 200 microns

Finish

Plain Singed One Side

Cerex Cover Singed Both Sides

Nylon Cover

Ring/ Flange options

Draw String No Ring

Plastic Flange Polypropylene

Carbon Steel Stainless Steel

Operating Conditions

Max differential pressure: 25 psid (5Bar)

Max Operating Temperature:

Nylon Felt: 300ºF (150ºC)

Polyester Felt: 300ºF (150ºC)

Polypropylene Felt : 200ºF (93ºC)

Viscous Felt : 250ºF (120ºC)

Nomex Felt : 400ºF (200ºC)

Teflon Felt : 450ºF (230ºC)

Applications

Acids Ink Jets

Adhesives Electroplating

Alcohols Esters

Amines Greases and Oils

Beverages Electronics

Solvents Parts Cleaning

Coating Products Inks

Fine Chemicals Lacquers

Water Machinery Cooling

Paints Resins

Plating Solutions Dyes

Features Benefits ■ Three dimensional construction ■ Economical alternative for high particle level fluids

■ Longer life bag filter with greater flow rates

■ Low density and high permeability

■ Wide chemical & thermal compatibility ■ Provides excellent compatibility with a wide range of

chemicals such as acids, bases and solvents

■ High quality products for almost every application

■ Complete line of bag filters ■ Wide selection of filtration media

■ Provides the most complete range of standard liquid filter

bags

■ Quality manufacturing ■ Consistent and reproducible particle removal

Page 176

Page 178: ZenPure - Q-Test

ZenPure Felt Bag Filters

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

d36 Rev. 2011.07

Felt Bag Filter Ordering Guide

Value Life bags combine unparalleled pleat integrity with our proprietary “Depth by Design”“Depth by Design” materials and construction gives EVP and MVP filters distinct per-formance, and economic, advantages versus com-mon pleated filter elements!

Options

4T - 4 columns of vertical pleats to increase surface area

(#3 and #4 bag only)

XL - double layered bag with an internal layer that captures

large particles of dirt so the outer bag can last longer

and filter the finer particles not caught by the inner

bag

EVP - Enhanced life vertical pleats to increase surface area

and life time (#1 and #2 bag only)

MVP - Maximum vertical pleat columns to increase surface

area and lifetime more than 16 times over standard

bag filters (#1 and #2 bag only)

MVP Pleated Bag filters

Value Life Pleat options

Test results from actual customer process

0

5

10

15

20

25

30

#2 Size Standard Bag Value-Life EVP Value-Life MVP

Su

rface A

rea (

Sq

-Ft)

0

2

4

6

8

10

12

14

16

18

20"X

" L

ife Im

pro

vem

et

Surface Area (Sq-Ft) Life Improvement

Material Finish Size Ring/ Flange Options

PE PP V N NO T

PE = Polyester Felt 0.5 B = Singed Both Sides 1 = 7" x 16" S = Carbon Steel HS = Handle Strap

PP = Polypropylene Felt 1 1 1 1 C = Cerex Cover 2 = 7" x 30.5 SS = Stainless Steel 4T = 4 Column Value Life

V = Viscose Felt 3 3 N = Nylon Cover 3 = 4" x 8" P = Plastic Flange XL = Extended Life

N = Nylon Felt 5 5 5 5 P = Plain 4 = 4" x 14" DS = Draw String EVP = Enhanced Life Verticle Pleat

NO = Nomex Felt 10 10 10 10 S = Singed One Side 7 = (612) 5.5" x 13" PR = Polypropylene MVP = Maximum Vertical Pleat

T = Teflon Felt 15 15 15 8 = (618) 5.5" x 19" N = No Ring

25 25 25 25 9 = (630) 5.5" x 31"

50 50 50 50 12 = 8 37" x 32"

75 75 30 =4.118" x10"

100 100 100 100 65 = 4.118 x 22"

150 PH2 = 7" x 32"

200 200 200 RP2 = 8" x 27"

RP4 = 4" x 14"

Felt Bag FiltersRemoval Rating (Microns)

Example - a Polypropylene Felt bag 100um size #3 with a plastic flange and handle strap would be PP-100-P-3-P-HS

Sp

ecia

l Req

uest

Sp

ecia

l Req

uest

Page 177

Page 179: ZenPure - Q-Test

Mono & Multifilament Mesh Bag Filters

ZenPure Z

en

Pu

re

®

Mono and Multifilament mesh bag filters fit a wide-variety

of applications and bag filter housings. Bag filters are

normally used in industrial applications where there is a lot

of heavy contamination in liquid fluid paths. The bags are

offered in a range from 5 to 800 um.

Monofilament mesh bag filters are made of a single

threaded material that is both strong and efficient. The

threads are thicker and stronger than a multifilament, offer-

ing a more exacting micron opening. Monofilament bags

are reuseable. Multifilament mesh bags are constructed of

multiple woven fibers that maximize bag strength at an eco-

nomical cost.

Filters can be customized to meet your application.

Materials of Construction

Nylon Monofilament

Polyester Monofilament

Polypropylene Monofilament

Nylon Multifilament

Polyester Multifilament

Bag Sizes

1, 2, 3, 4, 7, 8, 9, 12, 30, 65, PH2,

RP2 and others upon request.

Micron Sizes

5 to 800 microns

Finish

Plain

Ring/ Flange options

Draw String No Ring

Plastic Flange Polypropylene

Carbon Steel Seal Rite

Stainless Steel

Operating Conditions

Max differential pressure: 25 psid (5Bar)

Max Operating Temperature:

Nylon Monofilament: 300ºF (150ºC)

Polyester Monofilament: 300ºF (150ºC)

Polypropylene Monofilament: 200ºF (93ºC)

Nylon Multifilament: 300ºF (150ºC)

Polyester Multifilament: 250ºF (120ºC)

Applications

Acids Ink Jets

Adhesives Electroplating

Alcohols Esters

Amines Greases and Oils

Beverages Electronics

Solvents Parts Cleaning

Coating Products Inks

Fine Chemicals Lacquers

Water Machinery Cooling

Paints Resins

Plating Solutions Dyes

Features Benefits

■ Wide selection of micron sizes ■ Economical alternative for high particle level fluids

■ Provides the most complete range of standard liquid filter

bags

■ Complete line of bag filters

■ Wide chemical & thermal compatibility ■ Provides excellent compatibility with a wide range of chemicals such as acids, bases and solvents

■ High quality products for almost every application

■ Complete line of bag filters ■ Wide selection of filtration media

■ Quality manufacturing ■ Consistent and reproducible particle removal

Page 178

Page 180: ZenPure - Q-Test

ZenPure Mono & Multifilament Mesh Bag Filters

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-20012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

d37 Rev. 2011.07

Mono and Multifilament Mesh Bag Filter Ordering Guide

Ordering Instructions

Material : This three or four letter code designates filtration media used to construct the

filtration product.

Micron : Please check individual material for micron availability.

Finish: Plain

Size: This number indicates the filter bag size. Most bags fit into standard categories;

however, special sizes are available. Please refer to the price list for all sizes.

Ring/ Flange: Description of the ring/ flange type to be used.

Options: This item indicates a specific option choice. 4T - 4 columns of vertical pleats to increase surface area (#3 and #4 bag only)

8T - 8 columns of vertical pleats to increase surface area (#1 and #2 bag only)

BT - narrow cloth tape used to fabricate a stronger seam

HS - Handle Strap to make change-outs easier

XL - double layered bag with a internal layer that captures large particles of dirt so the

outer bag can last longer and filter the finer particles not caught by the inner bag

Material Finish Size Ring/ Flange Options

NMO PEMO POMO NMU PEMU

NMO = Nylon Mono 5 5 P = Plain 1 = 7" x 16" DS = Draw String 4T = 4 Column Value Life

PEMO = Polyester Mono 10 10 2 = 7" x 30.5 N = No ring 8T = 8 Column Value life

POMO = Polypro Mono 25 25 3 = 4" x 8" P = Plastic Flange BT = Bias Tape

NMU = Nylon Multi 35 35 30 4 = 4" x 14" PR = Polypropylene HS = Handle Strap

PEMU = Polyester Multi 50 50 50 7 = (612) 5.5" x 13" S = Carbon Steel XL = Extended Life

75 75 8 = (618) 5.5" x 19" SR = Seal Rite

100 100 100 100 100 9 = (630) 5.5" x 31" SS = Stainless Steel

125 125 125 12 = 8.37" x 32"

150 150 150 150 150 30 =4.118" x10"

200 200 200 200 200 65 = 4.118 x 22"

250 250 250 250 PH2 = 7" x 32"

300 300 300 300 300 RP2 = 8" x 27"

400 400 400 400 400 RP4 = 4" x 14"

600 600 600 600 600

800 800 800 800 800

Removal Rating (Microns)

Mono and Multifilament Mesh Bag Filters

Example - a Nylon Monofilament, 100um, size 3 bag, with a plastic flange and bias tape would be NMO-100-P-3-P-BT

Page 179

Page 181: ZenPure - Q-Test

Chem Bag

ZenPure Z

en

Pu

re

®

Chem Bags are designed for chemical purification and/or

dissolving solid chemicals in a bag filter housing. This

unique bag and filter combination allows for solid

substances to come in contact with a dynamic liquid flow

path. This will allow the solid contents in the Chem Bag to

purify or add to the liquid stream as required.

The Chem Bag has an internal sidewall that is impervious

to liquid. It is made out of high density polyethylene for

chemical compatibility. The liner forces the liquid to pass

through the entire column of solid substance. This allows

for maximum contact time and does not allow the chemical

to simply go around the bag like a normal bag filter would.

The clean effluent passes only through the bottom of the

bag filtering and keeps the solid material contained. The

top of the bag has a zipper so filling and change-outs are a

easy, clean, and safe operation.

The Chem Bag could also be filled with more that one

substance minimizing your need for additional housings. It

could also be used for small test runs in lab scale

experiments for proof of concept.

Materials of Construction

Bag material

Polyester Felt

Polypropylene Felt

Liner/side wall - High Density Polyethylene

Zipper - Nylon teeth, Polyester cloth

Bag Sizes

1, 2, 3, 4, 7, 8, 9, 12, 30, 65, PH2,

RP2, and other upon request.

Micron Sizes

0.5 to 200 microns

Finish

Plain Singed One Side

Singed Both Sides

Ring/ Flange Options

Plastic Flange Polypropylene

Carbon Steel Stainless Steel

Operating Conditions

Max differential pressure: 25 psid (5Bar)

Max Operating Temperature: 120ºF (50ºC)

Applications

Acids Ink Jets

Adhesives Electroplating

Alcohols Esters

Amines Greases and Oils

Beverages Electronics

Solvents Parts Cleaning

Coating Products Inks

Fine Chemicals Lacquers

Water Machinery Cooling

Paints Resins

Plating Solutions Dyes

Features Benefits

■ Lined inner wall ■ Contact with the entire solid material column in the bag

■ Allows for multiple materials in the same bag to

perform multiple process steps

■ Handle and zipper ■ Easy uses of filling and removing the bag.

■ Can easily dispose of entire bag with contents

■ Wide chemical & thermal compatibility ■ Provides excellent compatibility with a wide range of

chemicals such as acids, bases, and solvents

■ High quality products for almost every application

■ Quality manufacturing ■ Consistent and reproducible particle removal

Page 180

Page 182: ZenPure - Q-Test

ZenPure Chem Bag

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

d38 Rev. 2011.07

Chem Bag Filter Ordering Guide

Ordering Instructions

Material : The letter code designates filtration media used to construct the filtration product.

Micron : Please check individual material for micron availability.

Finish: Type of finish applied to the felt or the type of cover.

Size: This number indicates the filter bag size. Most bags fit into standard categories;

however, special sizes are available. Please refer to the price list for all sizes.

Ring/ Flange: Description of the ring/ flange type to be used.

Chem Bag: This code designates Chem Bag

Chem Bag Specials with different material or options can be requested for quotation.

Specials can be quoted upon request

Material Finish Size Ring/ Flange Chem Bag

PE PP

PE = Polyester Felt 0.5 P = Plain 1 = 7" x 16" S = Carbon Steel CB = Chem Bag

PP = Polypropylene Felt 1 1 S = Singed One Side 2 = 7" x 30.5 SS = Stainless Steel

3 3 3 = 4" x 8" P = Plastic Flange

5 5 4 = 4" x 14" PR = Polypropylene

10 10 7 = (612) 5.5" x 13"

15 8 = (618) 5.5" x 19"

25 25 9 = (630) 5.5" x 31"

50 50 12 = 8.37" x 32"

75 75 30 =4.118" x10"

100 100 65 = 4.118 x 22"

150 PH2 = 7" x 32"

200 200 RP2 = 8" x 27"

RP4 = 4" x 14"

Chem Bag FiltersMicrons

Example - a Polypropylene Felt bag, 100um, size #2, with a plastic flange PP-100-P-2-P-CB

Page 181

Page 183: ZenPure - Q-Test

Resinator Bag Filter

ZenPure Z

en

Pu

re

®

The Resinator combines the positive qualities of resin-bonded

cartridges with the proven advantages of a premium quality

bag filter. The users gain the non-compressibility of a resin

filter along with the greatly enhanced solids loading capacity

and cost savings of a gradient-density filter bag.

The Resinator’s patented design incorporates two layers of

fully infused phenolic resin textile; with the inner layer act-

ing as a pre-filter to the more retentive outer layer. This

proven gradient density approach, coupled with the increased

surface area, results in enhanced efficiencies and increased

filter lifetime. The Resinator’s non-compressible depth me-

dia is more effective than conventional filters in retaining gel-

like particles. Unlike cartridges, which accumulate debris on

the outside of the element and are prone to remnants falling

off the element during change-out, the Resinator bag filter

contains contaminates securely inside the bag. This not only

ensures the integrity of the filtration process, it builds an ef-

fective pre-filter cake that promotes higher efficiencies with-

out higher pressure drop or loss of flow capacity.

Materials of Construction

Bag Material - Double Layer Polyester

Resin - Phenolic

Bag Sizes

1, 2, 3, 4, 7, 8, 9, 12, 30, 65 and others upon

request.

Micron Sizes

1 to 200 microns

Finish

Heat Treated Finish

Ring/ Flange Options

Polypropylene Flange

Carbon Steel

304 Stainless Steel

Operating Conditions

Max differential pressure: 25 psid (1.7 bar)

Max operating temperature: 300ºF (150ºC)

Features Benefits

■ High loading capability ■ Fewer change-outs, thus more up time in your process

■ Replaces 12 resin bonded cartridges, therefore lower

disposal cost

■ Gradient density ■ Enhanced efficiencies and increased filter life

■ No fiber migration issues

■ Wide chemical & thermal compatibility ■ Provides excellent compatibility with a wide range of

chemicals such as acids, bases and solvents

■ High quality products for almost every application

■ Bag handles ■ Easy, clean change-out

■ Cost savings on faster change-out time

■ Can easily dispose of entire bag with contents

Just one Resinator bag filter can replace 12

Resin-bonded cartridges

=

Page 182

Page 184: ZenPure - Q-Test

ZenPure Resinator Bag Filter

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

d39 Rev. 2011.07

Resinator Bag Filter Ordering Guide

Specials can be quoted upon request

Note: The Resinator has not been tested for use in food, beverage, pharmaceutical, or potable water applications

Adhesives,

Coatings, and Inks

Petroleum

ProductsResins Water-based

Other

Applications

Adhesives Asphalts Acrylics Antifreeze Animal Oils

Emulsions Machine Coolants Alkyds Cooling Tower Water Cosmolene

Enamels Crude Oils Aminos Industrial Process Water Elastomers

Box Inks Hydraulic Fluids Epoxies Oil Well Completion Glycerin

Lacquers Kerosene Silicones Solutions Inorganic

Paints Silicon Oils Urethanes Salt Water Acids (dilute)

Sealants Waxes Vinyls Plasticizers

Shellac Rapeseed Oils

Varnishes Turpentine

Tung Oils

Typical Resinator Applications

Resinator Bag Filters Microns Finish Size Ring/ Flange

1 P = Plain 1 = 7" x 16" S = Carbon Steel

BRB 5 N = Quick Release Cover 2 = 7" x 30.5 SS = Stainless Steel

10 7 = (612) 5.5" x 13" P = Plastic Flange

25 (Heat treated finish) 8 = (618) 5.5" x 19"

50 9 = (630) 5.5" x 31"

75 12 = 8.37" x 32"

100

200

Resinator Bag Filters

Example - a Resinator bag, 10um, size #2, Plain finish, with a plastic flange is BRB10P2P

Page 183

Page 185: ZenPure - Q-Test

ZenPure Stainless Steel Disc Holder

Zen

Pu

re

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company. Copyright 2003-2012 ZenPure or an affiliated company. All rights reserved.

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

A5 Rev 2011.06

The Stainless Steel disc holder can be used for simple, quick, and efficient filtration of fluids and gases used in laboratory, pilot, and small scale applications. The disk holder accepts the PureFlo Membrane discs which is the same filter media used in full size PureFlo cartridges and capsules. This will ensure consistent scale-up of the product through laboratory, pilot, and full-scale production.

The compact design allows for low hold-up volume to minimize wasted fluid. The locking ring provides quick turn-around of sampling and testing with no tools required. The disk holder is designed to minimize differential pressure. This ensures accurate testing and results of the filter media.

The disc holder can be used for clarification, compatibil-ity, sampling, particle counter testing and other small scale applications.

Disc Holder Closure Mechanism

Diameter Inlet Fittings Outlet Fittings Vent O-Ring

DH = Stainless P = Locking Ring 025 = 25mm All sizes All sizes E = EPDMSteel Disc Holder T = San tary Clamp 047 = 47mm 1N = 1/8" MNPT 1N = 1/8" MNPT S = SILICON

090 = 90mm 1Q = 1/8" Male Qu ck Coupling 1Q = 1/8" Male Quick Coupling 2C = 1/4" Compression V = Fluoro-elastamer142 = 142mm 2C = 1/4" Compression 2C = 1/4" Compress on LF = Female Luer lock

2H = 1/4" Hose Barb 2H = 1/4" Hose Barb NV = No Vent2N = 1/4" MNPT 2N = 1/4" MNPT2Q = 1/4" Male Qu ck Coupling 2Q = 1/4" Male Quick Coupling3N = 3/8" MNPT 3N = 3/8" MNPTLF = Female Luer lock LF = Female Luer lock

90 and 142 size only 90 and 142 size onlyMT = 1/2" Tri clamps MT = 1/2" Tri clampsTC = 1-1/2" Tri clamp TC = 1-1/2" Tri clamp3T = 3/8" Weld Tube 3T = 3/8" Weld Tube 3H = 3/8" Hose Barb 3H = 3/8" Hose Barb Other fitting possible by reque Other fitting possible by request

1V = Valve w th 1/8" Hose Barb

Example - 47mm Stainless Steel Disk holder with 1/4" MNPT, no vent and EPDM oring - DHP0472N2NNVE

Stainless Steel Disc Holder Ordering Guide

Materials of Construction Head: 316L Stainless Steel Bowl: 316L Stainless Steel Screen: Sintered 316 Stainless Steel O-Rings: EPDM, Silicon , Fluoroelastomer

Dimensions (47mm version) Length: 2.75in (70mm) Width: 2.36in (60 mm)

Connections Inlet/Outlet : Compression, MNPT, and Hose Barb, Quick Coupling Vent: 1/4" Compression, Valve, Luer Lock or No vent

Finish Electropolished finish

Operating Conditions Max operating pressure: 87 psi (6 Bar)

DHT version

DHP version

Page 184

Page 186: ZenPure - Q-Test

ZenPure Stainless Steel Media Disc Holder

Zen

Pu

re

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

A5.1 Rev 2011.08

The Stainless Steel disc media holder can be used for simple, quick, and efficient filtration of fluids and gases used in laboratory, pilot, and small scale applications. The disk media holder accepts Media discs which from a size range from 0.1 to 5 mm. This will allow for testing of different media thickness variations as well as multiple layers.

The compact design allows for high hold-up volume to allow for filter caking and extended testing. The locking ring is the key to allow the different media thicknesses. It also allows for quick turn-around of sampling and testing with no tools required. The media holder is de-signed to minimize differential pressure thus ensuring accurate testing and results.

The media holder can be used for clarification, com-patibility, sampling, particle counter testing and other small scale applica-tions.

Disc Media

Holder

Closure

MechanismDiameter

Void Chamber

HeightInlet Fittings Outlet Fittings Vent O-Ring

DM = Stainless P = Locking Ring 025 = 25mm All sizes All sizes NV = No Vent E = EPDM047 = 47mm 1N = 1/8" MNPT 1N = 1/8" MNPT S = SILICON060 = 60mm 1Q = 1/8" Male Quick Coupling 1Q = 1/8" Male Quick V = Fluoro-elastamer090 = 90mm 2C = 1/4" Compression 2C = 1/4" Compression142 = 142mm 2H = 1/4" Hose Barb 2H = 1/4" Hose Barb 2C = 1/4" Compression

2N = 1/4" MNPT 2N = 1/4" MNPT LF = Female Luer lock2Q = 1/4" Male Quick Coupling 2Q = 1/4" Male Quick 3N = 3/8" MNPT 3N = 3/8" MNPTLF = Female Luer lock LF = Female Luer lock

60mm and Larger 60mm and Larger

MT = 1/2" Tri clamps MT = 1/2" Tri clampsTC = 1-1/2" Tri clamp TC = 1-1/2" Tri clamp3T = 3/8" Weld Tube 3T = 3/8" Weld Tube 3H = 3/8" Hose Barb 3H = 3/8" Hose Barb

Steel Disc Media Holder

Other fitting possible by request

1V = Valve with 1/8" Hose Barb

Example - 47mm Stainless Steel Disk Media Holder with 1/4" MNPT, no vent and EPDM O-ring - DMP0472N2NNVE

xxx = Specify Height in mm

Example:

127 = 127 mm height (5")

Stainless Steel Disc Media Holder Ordering Guide

Materials of Construction Head: 316L Stainless Steel Bowl: 316L Stainless Steel Screen: Perforated 316 Stainless Steel O-Rings: EPDM, Silicon , Fluoroelast-

omer Dimensions (60mm version)

Length: 8.7in (221mm) Width: 3.5in (90 mm)

Connections Inlet/Outlet: Compression, MNPT, and Hose Barb, Quick Coupling Vent: 1/4" Compression, Valve, Luer Lock

or No vent Finish

Electropolished finish Operating Conditions

Max operating pressure: 87 psi (6 Bar)

Page 185

Page 187: ZenPure - Q-Test

Virgin Polypropylene Housing

ZenPure Z

en

Pu

re

ZenPure virgin polypropylene housings have been specially

designed for critical applications that require a high degree of

cleanliness. No metal components are used in the construction

of the housing, therefore, eliminating the potential for ionic or

metallic contamination. In addition, the locking ring and

housing threads are external to the housing (non-wetted

surface) thereby reducing the potential for particles being

generated as the surfaces are tightened or loosened.

ZenPure virgin polypropylene housings are offered in 10” or

20” lengths that accept filter cartridges with 2-222 O-rings.

The compact design of the housings requires minimal installa-

tion space while reducing hold-up volume. ZenPure virgin

polypropylene housings can withstand high operating pres-

sures and are an economic alternative to metal housings.

Applications

Solvents Ink Jets

Fine Chemicals Electronics

Plating Solutions Pharmaceuticals

Process Water Biologics

Beverages Dyes

Parts Cleaning Lacquers

Materials of Construction

Head: Virgin Polypropylene

Bowl: Virgin Polypropylene

Locking Ring: Polypropylene

Vent / Drain Plugs: Virgin Polypropylene

O-Rings: Silicone, EPDM

Maximum Operating Pressure

100 psig (6.9Bar) @ 125°F (52° C)

125 psig (8.6 Bar) @ 68°F (20° C)

Lengths (Nominal): 10 in., 20 in.

Inlet / Outlet Connections: 3/4” NPT, 1” NPT

Features Benefits

■ Small Compact Design ■ Low hold-up volume

■ Minimal installation space required

■ 100% Polypropylene Construction ■ Eliminates the potential for metallic or ionic contamination

■ Provides excellent compatibility with a wide-range of fluids

■ Economic alternative to metal housings

■ External Locking Ring ■ Provides a robust and consistent seal

■ Able to withstand high operating pressures

■ Reduces the potential for particles being generated as the

mating surfaces are being tightened or loosened

Page 186

Page 188: ZenPure - Q-Test

ZenPure Virgin Polypropylene Housing

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

F59 Rev 2011.07

Virgin Polypropylene Ordering Guide

Filter

Nominal Length A B

10" 165mm (6.5in") 354mm (13.9")

20" 165mm (6.5in") 603mm (23.7")

Housing Construction

Material Configuration Cartridge Code

Housing Length

Vent / Drain Connections

Body Style

Inlet / Outlet Connections

O-Ring Materials

PH = Plastic

Housing

V = Virgin PP

01 = 1 Round

0 = 2-222

10 = 10” 20 = 20”

P = ¼” FNPT

T = T

Line

G = 3/4” FNPT * H = 1” FNPT **

E = EPDM S = Silicone

* 10” Length Only ** 20 “ Length Only

Example – 10”, Virgin Polypro Housing, with 2-222 EPDM O-Rings and 1” FNPT inlet and outlet connections would be PHV01010PTHE

0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0

0.01

0.02

0.03

0.04

0.05

0 5 10 15 20

0 10 20 30 40 50 60 70

PureFlo Virgin PP Housing

GPM

BarPSID

LPMD

iffe

ren

tia

l

Pre

ss

ure

Flow Rate @22°C, 1cP Fluid

10" Housing with 3/4" Fitting

20" Housing with 1" Fitting

Page 187

Page 189: ZenPure - Q-Test

Sanitary Mini Stainless Steel Housing

ZenPure Z

en

Pu

re

ZenPure® Sanitary Mini Stainless Steel housings are

designed for high purity applications. All wetted

surfaces are constructed of 316L stainless steel and are

electropolished, providing excellent corrosion resistance.

The housings are compatible with 1.5, 2.5 and 5 inch

Mini Filters to meet the needs of your small scale appli-

cation.

The housing can support the 116 o-ring size where the

orings are on the filter (code A) or the housing (code N).

The design of the housing provides for a positive seal

with the filters thereby preventing fluid bypass. The

housing is sealed by the use of an easy to use tri-clamp

that requires no special tools to open or close.

These sanitary mini stainless steel housings are ideal for

laboratory, small production or pilot scale operations.

The ZenPure mini filters utilized with these housing can

be scaled up to as large as 40" filter.

Materials of Construction

Head: 316L Stainless Steel

Bowl: 316L Stainless Steel

Clamp: 304 Stainless Steal

Center post with Seel plate: 316 Stainless Steel

Vent/ Drain Plug: 316L Stainless Steel

O-Rings: Silicone, EPDM, Viton

Dimensions (nominal)

Filter Lengths: 1.5in., 2.5in., 5in.

Width: 2.5in (64 mm)

Connections

Inlet/ Outlet : ½", 1", 1.5" sanitary fitting

Vent / Drain: welded valve, 1.4" FNPT,

or no vent/drain

Finish

Electropolished

Operating Conditions

Max liquid operating pressure: 87 psi (6 bar)

Applications

Solvents Ink

Fine Chemicals Pilot Lab Applications

Plating Solutions Pharmaceuticals

Process Water Biologics

Beverages Dyes

Parts Cleaning Lacquers

Features Benefits

■ Wide Chemical & Thermal Compatibility ■ Provides excellent compatibility with a wide range of

chemicals

■ The electropolished finish eliminates possible contamination

that could potentially leach into the process chemicals.

■ Three different sizes ■ Allows you to pick the amount of filtration area to minimize

filtration cost and hold-up volume

■ Tri-clamp for housing ■ The housing allows for inspection of the filter before the

housing is sealed

■ Ease of filter change-out

Page 188

Page 190: ZenPure - Q-Test

ZenPure Sanitary Mini Stainless Steel Housing

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

G62 Rev 2011.07

Sanitary Stainless Steel Mini-Housing Ordering Guide

T– Style

With Vents

Without Vents With 1” Sanitary

Fittings

Dimentions

1.5" Filter 2.5" Filter 5" Filter

In-Line 159 193 243

T-Line 159 189 241

Overall Length (L) mm

Actual length will vary with different fittings

In Line– Style

Housing

ConstructionMaterial Cartridge #

Cartridge

CodeLength Vent/ Drain Body Style Inlet/Outlet

Gasket

Materials

SM = Sanitary P = 316L 01 = 1 Round A = 116 01 = 1.5" T = T-LINE A = 1/2" TC, 1/2" Pipe E = EPDMMini-Housings 02 = 2.5" I = IN-LINE B = 1" TC, 1" Pipe S = SILICON

05 = 5" N = No V/D C = 3/4" TC, 19mm Pipe V = VITON F = 1/2" Butt weld pipe G = 1/4" NPT H = 3/8" Hose barb I = 3/8" FNPT

Example - 5" Sanitary T-line Mini SS housing with Silicon gaslet, no Vent for 116 oring filter with 1" TC connection - SMP01A05NTBS

N = 116 Inner Housing seal

V = Welded valves

P = 1/4" FNPT (for T-Line

Page 189

Page 191: ZenPure - Q-Test

Sanitary Stainless Steel Housing

ZenPure Z

en

Pu

re

ZenPure® sanitary stainless steel housings are designed for high

-purity applications. All wetted surfaces are constructed of

316L stainless steel and are electropolished, there by providing

excellent corrosion resistance. The housing comes in 5 inch to

30 inch sizes to meet the needs of your application.

The housing can support both Code 0 with 2-222 o-rings and

Code F, double open-ended filters. The design of the housing

provides for a positive seal with the filters, thereby preventing

fluid bypass. The unique design for Code F filters allows for

cost saving and ease of installation. The housing is sealed by

the use of an easy to use tri-clamp that requires no special tools

to open or close.

Materials of Construction

Head: 316L Stainless Steel

Bowl: 316L Stainless Steel

Clamp: 304 Stainless Steel

Center post with Seal plate: 316 Stainless Steal

Vent/ Drain Plug: 316L Stainless Steel

O-Rings: Silicone, EPDM

Dimensions (nominal)

Lengths: 5 in., 10 in., 20 in., 30 in.

Width: 5.51 in. (140mm)

Connections

Inlet/ Outlet : ½", 1", 1.5" sanitary fitting

Vent / Drain :½" sanitary, or welded valve

Finish

Electropolished

Operating Conditions

Max operating pressure: 145 psi (10Bar)

Features Benefits

■ Wide Chemical & Thermal Compatibility ■ Provides excellent compatibility with a wide range of

chemicals

■ The electropolished finish eliminates possible contamination

that could potentially leach into the process chemical.

■ Mounting ■ T-line housing can be supported by tripod legs, rigid tubing,

or wall-mounted bracket

■ Tri-Clamp ■ The housing allows for inspection of the filter before the

housing is sealed.

■ Ease of filter change-out

Applications

Solvents Ink Jets

Fine Chemicals Electronics

Plating Solutions Pharmaceuticals

Process Water Biologics

Beverages Dyes

Parts Cleaning Lacquers

Page 190

Page 192: ZenPure - Q-Test

ZenPure Sanitary Stainless Steel Housing

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

G63 Rev 2011.07

Item Description Material Size

1 Bowl 316L SS 5,10,20,30"

2 Tri-Clamp 304 SS 4"

3 O-ringEPDM/ Silicon/

Viton/ PTFE 4"

4 Base 316L SS 1/2", 1", 1.5"

5 Valve 316L SS

Nominal Length L (T-Line) L1 (In-Line) L2 (In-Line) W (In-Line)

5" 182mm (7.16") 226mm (8.9") 238mm (9.37") 135mm (5.31")

10" 343mm (13.5") 387mm (15.24") 399mm (15.7") 135mm (5.31")

20" 597mm (23.5") 641mm (25.24") 653mm (25.7") 135mm (5.31")

30" 838mm (33.0") 895mm (35.24") 907mm (35.7") 135mm (5.31")

Housing

ConstructionMaterial Cartridge #

Cartridge

CodeLength Vent/ Drain Body Style Inlet/Outlet

Gasket

Materials

SH = Sanitary P = 316L 01 = 1 Round 0 = 2-222 05 = 5" A = ½" TC T = T-Line A = 1/2" TC E = EPDM

Housings 7 = 2-226 10 = 10" V = Welded I = In-Line B = 1" TC S = Silicone

20 = 20" valves C = 1.5" TC V = Viton

30 = 30" F = PTFE

40 = 40"Example - 10" Sanitary T-line SS housing with Silicon gaslet for Code 0 filter with 1" TC connection - SHP01010ATBS

Sanitary Stainless Steel Housing Ordering Guide

1

2

3

4

5

101 6 ±2

211

L

238

110

L2

L1

W

1 5” TC

1 5” TC

Page 191

Page 193: ZenPure - Q-Test

ZenPure Sanitary SS Filter Housing Multi-Round

Zen

Pu

re

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

G64 Rev 2011.07

®

ConstructionNumber of

F iltersConfiguration Length

Cartridge

Code

Inlet/Outlet

F itting Size

Inlet/Outlet

F itting StyleVent/Drain

Gasket

Material

Interior/Exterior

F inish

1 = 1 Filter I = In-Line 1=10" 7 = 2-226 1 = 1" TC = Tri Clamp TC = 1/2" Tri Clamp E = EPDM EP = Electropolish

SAN = Sanitary 3 = 3 Filters T = T-line 2=20" 8 = 2-222 2 = 2" V = 1/4" Valve V = Viton

High Purity 5 = 5 Filters 3=30" S = Silicon

6 = 6 Filters 4=40"

7 = 7 Filters

12 = 12 Filters

Example - 30"- 3 round for 222 filter, T-line, 2" Tri Clamp I/O, 1/2" Tri Clamp V/D, EPDM Gasket and Electropolished is SAN3T382TCTCEEP

The Sanitary Stainless Steel filter housings are constructed

of electropolished 316L stainless steel for excellent resis-

tance to corrosive chemicals and product purity. These

housings are typically used in the Pharmaceutical industry.

The housing is compatible with 10" to 40" filters elements

to meet the needs of your application. The housing can sup-

port 222 and 226 style filters. Housings from 1 to 12 rounds

are available to fit your flow rate. T-line and in-line configu-

rations allow flexibility in piping options.

The design of the housing provides for a positive seal with

the filters, thereby preventing fluid bypass. The unique de-

sign for closure with fixed bolts and opti-clamp hold down,

ensure maximum strength and ease of operation. The hous-

ing has a removable separator plate with a double o-ring

seal that allows for complete disassembly for cleaning.

Customization of the housing is available.

Materials of Construction

Head: 316L Stainless Steel

Bowl: 316L Stainless Steel

Clamp: 304 Stainless Steel

Vent/Drain Plug: 316L Stainless Steel

O-Rings: Silicone, Viton or EPDM

Dimensions (nominal)

Lengths (in): 10 , 20, 30 and 40

Connections

Inlet/ Outlet : Tri Clamp

Vent / Drain : Tri Clamp, Valve

Finish

Electropolished, <20Ra

Operating Conditions

Max operating pressure:

125 psi (10Bar) at 200°F (93°C)

Test Pressure :

165psi (11.4 Bar)at 75°F (24°C)

Applications Acids Plating Solutions

Bases Electronics

Solvents Pharmaceuticals

Fine Chemicals Biologics

Sanitary Filter Housing Ordering Guide

Note - Not all options are available on all sizes of housings. See cut sheets for more detail

Page 192

Page 194: ZenPure - Q-Test

Industrial Stainless Steel Housing

Single Round

ZenPure Z

en

Pu

re

ZenPure® industrial stainless steel housings are designed to

meet your critical high-purity chemical processing needs.

The housing is constructed of 316L stainless steel for

excellent resistance to corrosive chemicals. The housing is

compatible with 5 inch to 30 inch filters lengths to meet the

needs of your application.

Code U housings can support both Code 0 with 222 o-rings

and Code F, double open-ended filters. The unique design

of the Code U housing allows for cost saving and ease of

installation. You can engage DOE filter before closing the

housing to ensure they are properly sealed. The design of

the housing provides for a positive seal with the filters

thereby preventing fluid bypass. The housing is sealed by

the use of an easy to use tri-clamp that requires no special

tools to open or close.

Materials of Construction

Head: 316L Stainless Steel

Bowl: 316L Stainless Steel

Clamp: 304 Stainless Steel

Center Post with Seal Plate: 316L SS

Vent/Drain Plug: 316L Stainless Steel

O-Rings: Silicone or EPDM

Dimensions (nominal)

Lengths (in): 5 , 10 , 20, and 30

Width: 5.51 in. (140mm)

Connections

Inlet/ Outlet : ¾" or 1"

Vent / Drain : ¼" NPT, ¼" BSP

Finish

Electropolished

Operating Conditions

Max operating pressure: 145 psi (10Bar)

Applications

Solvents Ink Jets

Fine Chemicals Electronics

Plating Solutions Pharmaceuticals

Process Water Biologics

Beverages Dyes

Parts Cleaning Lacquers

Features Benefits

■ Wide Chemical & Thermal Compatibility ■ Provides excellent compatibility with a wide range of

chemicals

■ The electropolished finish eliminates possible contamination

that could potentially leach into the process chemicals

■ Tri-Clamp ■ The housing allows for inspection of the filter before the

housing is sealed

■ Ease of filter change-out

■ Universal Housing ■ Allows the user to change between filters with 222 o-rings

and double open-ended in the same housing.

Page 193

Page 195: ZenPure - Q-Test

ZenPure Industrial Stainless Steel Housing

Single Round

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

G65 Rev 2011.07

Nominal Length H1 (Bowl Height) H (Overall Height)

5" 167mm (6.57") 246mm (9.69")

10" 300mm (11.81") 379mm (14.92")

20" 550mm (21.65") 629mm (24.76")

30" 800mm (31.5") 879mm (34.6")

Item Description Material Size

1 Base 316L SS 3/4 or 1"

2 Bowl 316L SS 5,10,20,30"

3 Tri-Clamp 304 SS

4 O-ring EPDM/Silicon 110x3.1

5 Plug 316L SS 1/4" NPT

Industrial Stainless Steel Housing Ordering Guide

Housing

ConstructionMaterial Cartridge #

Cartridge

CodeLength VENT/ DRAIN BODY STYLE INLET/OUTLET

O-Ring

Materials

IH = Industrial P = 316L 01 = 1 Round 0 = 2-222 05 = 5" P = 1/4" FNPT T = T-LINE G = 3/4" FNPT E = EPDMHousings F = DOE 10 = 10" (plugs included) H = 1" FNPT S = Silicone

U = Universal 20 = 20" Q = 1/4" BSP J = 3/4" BSP(DOE & 222) 30 = 30" K = 1" BSP

Example - 10" Industrial SS housing with silicon o-ring for 222 filter with 3/4" FNPT connection - IHP01010PTGS

Page 194

Page 196: ZenPure - Q-Test

ZenPure Industrial High Purity SS Filter Housing

Zen

Pu

re

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

G67 Rev 2011.07

®

ConstructionNumber of

F iltersConfiguration Length

Cartridge

Code

Inlet/Outlet

F itting size

Inlet/Outlet

F itting StyleVent/Drain

Gasket

MaterialInterior/Exterior F inish

1 = 1 Filter IN = In-Line 1=10" 1 = DOE 1.5 = 1.5" TC = Tri-Clamp 1/4TC = 1/4" Tri-Clamp E = EPDM BBP = Bead Blast & Passivate

IHP = Industrial 3 = 3 Filters M = T-line Machined 2=20" 2 = Cup and Post 3/4 = 3/4" F = Flange 1/4N = 1/4" FNPT V = Viton EP = Electropolish

High Purity 5 = 5 Filters TB = T-line, Bottom Open 3=30" 7 = 2-226 1 = 1" N = FNPT 1/2TC = 1/2" Tri-Clamp S = Silicon

6 = 6 Filters TT = T-line, Top Open 4=40" 8 = 2-222 2 = 2" 1/2N = 1/2" FNPT

7 = 7 Filters OT= Offset, Top Open 3 = 3"

12 = 12 Filters 4 = 4"

21 = 21 Filters

22 = 22 Filters

26 = 26 Filters

Example - 30"- 12 round for 222 filter, T-line with top opening, 3" Flange, 1/2" Tri Clamp, EPDM Gasket and Electropolished is IHP12TT383F1/2TCEEP

The industrial high purity stainless steel cartridge filter

housings are designed to meet your critical high purity

chemical processing needs. These housings are com-

monly used in the food and beverage industries. The

housing is constructed of 316L stainless steel for excel-

lent resistance to corrosive chemicals. The housing is

compatible with 10" to 40" filter elements to meet the

needs of your application flow.

The housing can support 222 and 226 o-rings and Code

F, double open-ended filters. A complete line of hous-

ings from 1 to 26 round are available to fit any flow rate.

The design of the housing provides for a positive seal

with the filters, thereby preventing fluid bypass.

T-line and offset configurations allow flexibility in pip-

ing options. The housing has an unique closure with

fixed bolts and opti-clamp hold downs that ensure maxi-

mum strength and ease of operation.

Materials of Construction Head: 316L Stainless Steel

Bowl: 316L Stainless Steel

Clamp: 304 Stainless Steel

Center Post with Seal plate: 316L SS

Vent/ Drain Plug: 316L Stainless Steel

O-Rings: Silicone, Viton or EPDM

Dimensions (nominal) Lengths (in): 10 , 20, 30 and 40

Connections Inlet/ Outlet : Tri-Clamp, Flange, FNPT

Vent / Drain : Tri-Clamp, FNPT

Finish Exterior: Electropolished, Bead Blast

Interior: Electropolished, Bead Blast

Operating Conditions Max operating pressure:

125 psi (10 bar) @200°F (93°C)

Test Pressure :

165psi (11.4 Bar)@75°F (24°C)

Applications

Acids Ink Jets

Bases Electronics

Solvents Pharmaceuticals

Fine Chemicals Biologics

Plating Solutions Dyes

Parts Cleaning Lacquers

Industrial High Purity Filter Housing Ordering Guide

Note- Not all options are available on all sizes of housings. See cut sheets for more detail.

Multi-Round

Page 195

Page 197: ZenPure - Q-Test

ZenPure Industrial Economy Filter Housing Multi-Round

Zen

Pu

re

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

G68 Rev 2011.07

®

ConstructionNumber

of F iltersLength

Cartridge

Code

Inlet/Outlet

F itting Size

Inlet/Outlet

F itting StyleVent/Drain

Gasket

MaterialInterior/Exterior F inish

3 = 3 Filters 1=10" 1 = DOE 1.5 = 1.5" TC = Tri-Clamp TC = 1/2" Tri-Clamp E = EPDM BBP = Bead Blast & Passivate

IE = Industrial 5 = 5 Filters 2=20" 2 = Cup and Post 2 = 2" F = Flange N = 1/2" FNPT EP = Electropolish

Economy 6 = 6 Filters 3=30" 7 = 2-226 N = FNPT V = 1/4" Valve

7 = 7 Filters 4=40" 8 = 2-222

Example - 30"- 3 round for 222 filter, 2" Tri-Clamp I/O, 1/2" Tri-Clamp V/D, EPDM Gasket and Electropolished is IE3382TCTCEEP

The industrial economy stainless steel filter housings are

constructed of 316L stainless steel for excellent resistance

to corrosive chemicals and to ensure product purity. The

housing is compatible with 10" to 40" filters elements to

meet the needs of your application.

The housing can support 222 and 226 o-rings and Code F,

double open-ended filters. A line of housings from 1 to 7

rounds are available to fit your flow rate needs. The

unique design for Code F filters allows for cost saving and

ease of installation.

The offset configurations allows rapid pluming installa-

tion. The design of the housing provides for a positive

seal with the filters, thereby preventing fluid bypass. The

unique design for closure with fixed bolts and opti-clamp

hold down to ensure maximum strength and ease of op-

eration.

Customization of the housing is available.

Materials of Construction

Head: 316L Stainless Steel

Bowl: 316L Stainless Steel

Clamp: 304 Stainless Steel

Center Post with Seal plate: 316L SS

Vent/Drain Plug: 316L Stainless Steel

O-Rings: Silicone, Viton or EPDM

Dimensions (nominal)

Lengths (in): 10 , 20, 30 and 40

Connections - Offset

Inlet/Outlet : Tri Clamp, Flange, FNPT

Vent/Drain : Tri Clamp, FNPT, Valve

Finish

Interior/Exterior: Bead Blast, Electropolished

Operating Conditions

Max operating pressure:

125 psi (10bar) at 200°F (93°C)

Test Pressure :

165psi (11.4 bar) at 75°F (24°C)

Applications Acids Ink Jets

Bases Electronics

Solvents Parts Cleaning

Fine Chemicals Lacquers

Plating Solutions Dyes

Industrial Economy Filter Housing Ordering Guide

Note- Not all options are available on all sizes of housings. See cut sheets for more detail.

Page 196

Page 198: ZenPure - Q-Test

ZenPure Band Clamp SS Filter Housing Multi-Round

ZenP

ure

ZenPure Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

G68.5 Rev 2011.07

®

ConstructionNumber of

F iltersLength

Inlet/Outlet

F itting Size

Inlet/Outlet

F itting Style

Outlet

Configurations

Material of

Construction

Pressure

Rating

Interior /

Ex terior

F inish

4 = 4 Filters 1=10" 2 = 2" F = RF Flange 4 = 304SS PC = Poly-Coat

5 = 5 Filters 2=20" 3 = 3" M = MNPT 6 = 316SS

7 = 7 Filters 3=30" 4 = 4" TC = Tri-Clamp

12 = 12 Filters 4=40"

22 = 22 Filters

Example - 30"- 4 round , 2" Tri-Clamp I/O, Opposite Side Outlet, 304SS, Buna N Gasket is GTCHB432TC2415PC

GTCHB = Band

Clamp SS Filter

Housing

2 = Opposite Side

Outlet

15 = 150 PSI

@ 250 F

Band Clamp Filter Housing Vessels

are designed for industrial and commercial applications. Vessels

are constructed of 304 or 316 stainless steel and accept DOE,

222/FLAT, and 222/FIN end cartridges in 10”, 20”, 30” & 40”

nominal lengths.

Materials of Construction Housing: 316/ 304 Stainless Steel

Clamp: 304 Stainless Steel Cap Spring: 316L SS

O-Rings: Buna N

Dimensions (nominal) Lengths (in): 10 , 20, 30 and 40

Connections - Offset

Inlet/Outlet : Tri Clamp, Flange, FNPT Vent/Drain : FNPT

Finish

Interior: 2B finish Exterior: PolyCoat

Operating Conditions

Max operating pressure: 150 psi (10bar)

Note- Not all options are available on all sizes of housings

Features:

• Single o-ring design (Buna-N standard)

• Easy-access self-centering heavy-duty band-clamp closure

• 316 stainless steel universal seal cups and compression plates allow

vessels to accept D OE , -222/FLAT, or -222/FIN-end cartridges

• 304 & 316 stainless steel construction

• Poly-coat finish (exterior only)

• 150 PSI pressure rating

• Heavy-duty welded mounting/support legs

• 316 stainless steel cap/spring assemblies and v-posts

Heavy - Duty Band Clamp

Vent

Fin or flat - End Cartridge DOE Cartridge

Guage Port

Drain Port (dirty)

D r a i n P o r t (Clean)

Inlet

Outlet

Band Clamp Filter Housing Ordering Guide

Page 197

Page 199: ZenPure - Q-Test

Industrial High Purity Bag Filter Housing

ZenPure Z

en

Pu

re

®

The industrial high-purity stainless steel bag filter housings

are designed to meet your critical high purity chemical proc-

essing needs. These housings are commonly used for indus-

trial applications where gross contamination is a concern.

The housing is constructed of 316L stainless steel for excel-

lent resistance to corrosive chemicals. The housing is com-

patible with number 2 bag filters to meet the needs of your

application flow.

The offset configurations allows rapid pluming installation.

The design of the housing provides for a positive seal with

the filters, thereby preventing fluid bypass. The unique de-

sign for closure with fixed bolts and opti-clamp hold down to

ensure maximum strength and ease of operation.

Customization of the housing is available.

Materials of Construction

Head: 316L Stainless Steel

Bowl: 316L Stainless Steel

Clamp: 304 Stainless Steel

Vent/ Drain Plug: 316L Stainless Steel

O-Rings: Silicone, Viton or EPDM

Dimensions (nominal)

Lengths (in): ~46" Ref for Bag #2

Connections

Inlet/ Outlet : Tri-Clamp, Flange

Vent / Drain : Tri-Clamp, FNPT

Finish

Exterior: Electropolished, Bead Blast

Interior: Electropolished, Bead Blast

Operating Conditions

Max operating pressure:

125 psi (10 bar) at 200°F (93°C)

Test Pressure :

165psi (11.4 Bar) at 75°F (24°C)

Applications

Acids Ink Jets

Bases Electronics

Solvents Pharmaceuticals

Fine Chemicals Biologics

Plating Solutions Dyes

Parts Cleaning Lacquers

Features Benefits

■ Wide Chemical & Thermal Compatibility ■ Provides excellent compatibility with a wide range of

chemicals

■ The electropolished finish eliminates possible contamination

that could potentially leach into the process chemicals

■ Omega Ring ■ Provides easy removal of the bag and it’s captured particulate

matter

■ Security to hold the bag in place, preventing any dislodging

of the filter bag from any back pressure

Page 198

Page 200: ZenPure - Q-Test

ZenPure Industrial High Purity Bag Filter Housing

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

G69 Rev 2011.07

Industrial High Purity Bag Filter Housing Ordering Guide

39.00"

5.50"

3.50"

VENT

OMEGA RING

#2 BAG FILTER

OUTLET

O-RING SEAL

O-RING SEAL

DRAIN

INLET

10"Ø BOLT CIRCLE

46.00" REF

BOTTOM VIEW

FRONT

Typical Water Flow Rate Vs. PSID

0

2

4

6

8

10

0 25 50 75 100

GPM

PS

ID

Construction Bag #Inlet/Outlet

F itting size

Inlet/Outlet

F itting StyleVent/Drain

Gasket

MaterialInterior/Exterior F inish

IHPB = Industrial 2 = Number 2 2 = 2" TC = Tri-Clamp 1/2TC = 1/2" Tri-Clamp E = EPDM BBP = Bead Blast & Passivate

High Purity N = FNPT 1/2N = 1/2" FNPT V = Viton EP = Electropolish

Bag Housing S = Silicon

Example - #2 Bag filter housing with Tri-Clamp fittings and 1/2" Tri-Clamp Vent/Drain, EPDM Gasket and Electropolished is IHPB22TC1/2TCEEP

Note: Dimensions are for reference only. Design drawings available upon request.

Page 199

Page 201: ZenPure - Q-Test

ZenPure SRL Series Bag Housings

ZenP

ure

ZenPure Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

H70 Rev 2011.07

®

SRL Low flow Series vessels come in two standard

sizes tailored to your throughput requirements. The

SRL 1-30 is rated for 30 gpm, and the SRL 1-65 at

65 gpm. Both sizes are available in three different

closure designs: Band Clamp, Swing Bolt, or Swing

Away. Available with 100, 200, or 300 psi ratings.

Materials of Construction

Head: 316,304, Carbon Steel

Bowl: 316,304, Carbon Steel

O-Rings: Silicone, Viton or

EPDM (standard)

Orientation

Side-in/ Bottom-out (Standard)

Side-in/ Side-out (optional)

Connections Inlet/Outlet : FNPT, Tri-Clamp

Maximum Recommended Flow Rates and Surface Area For the following recommended flow rates, vessels need a minimum inlet/

outlet size of 1" NPT. The recommended flow for basket and filter combina-

tion is for nominally rated filter bags, not for our high efficiency filter bag

SRL Bag Filter Housing Ordering Guide

SRL 1-30 60 gpm 45 gpm 30 gpmSRL 1-65 125 gpm 90 gpm 65 gpm

ProductBasket Strainer

Mesh Lined Basket Strainer

Retainer Basket with Filter Bag

Optional Features

• Inlet/outlet orientation: Side-in Bottom-out (Standard) or Side-in Side-out (optional)

• Epoxy coating, electopolish and fuse coating

• Low pressure drop, positive cover seal

• Higher pressure ratings available up to 3,000 PSI

• Easily cleaned • Jacketing

• Heavy duty perforated basket • Compression devices

• ASME code stamp available on all designs

• Custom designs

• Band clamp and swing bolt closures

• Sanitary construction

• .25" NPT vent tap • Mesh-lined basket for straining applications - 50 micron and higher

• Pop sizes from .5" to 2" NPT, RFF or Quick Disconnect connections

• Greater surface area than our competitors' equivalent models

Standard Features

Housing Construction Bag Size

Inlet/Outlet Size (inch)

Inlet/Outlet Fitting Style Material Closure Mechanism Other Options

30 = 4"x10" 0.5 Blank = FNPT A = Carbon Steel BC100 = Band Clamp 100psi CM = Clamp Mount 4.5" Carbon SteelSRL 65 = 4" x 22" 1 TC = Tri-Clamp B = 304 SS BC200 = Band Clamp 200psi CMS = Clamp Mount 4.5" SS

1.5 C = 316 SS SB300 = Swing Bolt 300psi TP = Tripod Stand Carbon Steel2 SW = Swing away TPS = Tripod Stand SS

GT = Gauge TapsHD = Bag Compression DeviceSO = Side Output

Example - a 304SS SRL bag filter housing,size #65,1"FNPT, and 100psi Band Clamp is SRL-65-1-B-BC200

Page 200

Page 202: ZenPure - Q-Test

ZenPure SRS Series Bag Housings

ZenP

ure

ZenPure Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

H71 Rev 2011.07

®

SRS Standard Series filter bag/strainer vessels are

designed with a recessed basket and new horizontal

pivoting cover. The new design achieves an advanced

bag-to-vessel seal. These vessels are available in #1

and #2 sizes in a variety of pressure ratings with 150

psi being standard. Standard swing bolt closure allows

for quick accessibility when a filter bag or strainer

needs replacement. The SRS is an outstanding combi-

nation of performance and value.

Materials of Construction

Head: 316,304, Carbon Steel

Bowl: 316,304, Carbon Steel

O-Rings: Silicone, Viton or

EPDM (Standard

Orientation

Side-in/ Bottom-out (Standard)

Side-in/ Side-out (optional)

Connections

Inlet/Outlet : FNPT, Flange

Maximum Recommended Flow Rates and Surface Area For the following recommended flow rates, vessels need a minimum inlet/outlet

size of 2" NPT. The recommended flow for basket and filter combination is for

nominally rated filter bags, not for our high efficiency filter bag line.

SRS Bag Filter Housing Ordering Guide

Shown with optional compression device

SRS 1-2 SRS 2-2100 gpm* 200 gpm

*Rates are for nominally rated bags only

Standard Features

• Adjustable height tripod stand

• Inlet/outlet orientation: Side-in Bottom-out (standard) or Side-in Side-out (optional)

• Low pressure drop

• Positive cover seal

• Easily cleaned

• Heavy duty perforated basket

• Swing bolt closures

• .25" NPT vent tap

• Pipe sizes from .75" to 3" NPT, RFF or Quick Disconnect connections

Optional Features

• Epoxy coating, electopolish and fuse coating

• Jacketing

• Compression devices

• Wire mesh support baskets

• Mesh-lined basket for straining applications - 50 micron and higher

Housing Construction Bag Size Inlet/Outlet

Size (inch) Fitting Style Material Other Options

1 0.75 Blank = FNPT A = Carbon Steel SSS = Stainless Steel Swing BoltsSRS 2 1 F = Flange B = 304 SS SST = Stainless Stand

1.5 C = 316 SS D = 1" NPT Drain2 SO = Side Output3 GT = Gauge Taps

MB4 = Mesh Basket 304SSMB6 = Mesh Basket 316SSHD = Bag Compression Device

Example - a 304SS SRS bag filter housing,size #1, 2"FNPT is SRS-1-2-NB

Page 201

Page 203: ZenPure - Q-Test

ZenPure SRH Series Bag Housings

Zen

Pu

re

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

H72 Rev 2011.07

®

All SRH Series filter bag/strainer vessels are designed

for heavy service. The SRH housings come with a re-

cessed basket, a volume displacer permanently welded

to the top cover, and a stainless steel wire mesh retainer

basket.

Our standard wire mesh baskets increase available fil-

tration surface area up to 30% compared to the perfo-

rated retainer baskets that come standard with competi-

tors’ vessels. This unique and efficient design results in

longer filter life and decreased labor costs.

Materials of Construction

Head: 316, 304, Carbon Steel

Bowl: 316, 304, Carbon Steel

O-Rings: Silicone, Viton or

EPDM (standard)

Orientation

Side-in/ Bottom-out (Standard)

Side-in/ Side-out (optional)

Connections

Inlet/Outlet : Flange, FNPT

Maximum Recommended Flow Rates and Surface Area For the following recommended flow rates, vessels need a minimum inlet/outlet

size of 2" NPT. The recommended flow for basket and filter combination is for

nominally rated filter bags, not for our high efficiency filter bag line.

Standard Features • Adjustable height tripod stand

• Built-in volume displacer located on cover

• Inlet/outlet orientation: Side-in Bottom-out (standard)

or Side-in Side-out (optional)

• Low pressure drop

• Positive cover seal

• 150 psi design, available up to 3,000 psi

• Easily cleaned

• Stainless steel wire mesh basket

• ASME Code stamp available on all SRH style vessels

• Swing bolt closures

• .25" NPT vent tap

• Pipe sizes from .75" to 4" NPT, RFF or quick discon-

nect connections

Mesh Lined Retainer Basket

Basket Strainer with Filter Bag

SRH 1 150 gpm 110 gpm 100 gpm 2.25

SRH 2 300 gpm 220 gpm 200 gpm 4.5

Product

Basket

Strainer

Surface Area

Sq. Ft.

SRH Bag Filter Housing Ordering Guide Housing

ConstructionBag Size

Inlet/Outlet

Size (inch)Fitting Style Material Other Options

1 0.75 Blank = NPT A =Carbon Steel GT = Gauge Taps

SRH 2 1 (0.75-3" only) B = 304 SS HD = Bag Compression Device

2 F = Flange C = 316 SS MB4 = Mesh Basket 304SS

3 MB6 = Mesh Basket 316SS

4 PC = Powder Coat for CS

SO = Side Out

SSS = SS Swing Bolts

U = ASME Code

UM = ASME Code

Example - a 304SS SRH bag filter housing,size #2, with a 3" flange is SRH-2-3F-B

Page 202

Page 204: ZenPure - Q-Test

ZenPure SRM Series Multi-Cavity Housings

Zen

Pu

re

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

H73 Rev 2011.07

®

SRM Multi-cavity filter vessels offer large surface areas

capable of handling up to 5,600 gpm in a single housing.

The increased surface area allows for longer processing

time prior to filter change-out. The multi-cavity vessels

can contain anywhere from two to 28 bags/baskets in a

single vessel. Our standard side-inlet side-outlet design

offers the greatest inlet/outlet flexibility and doesn’t re-

quire a platform to be built in order to change-out or clean

the filter bag or strainers.

Materials of Construction

Head: 316L, 304, Carbon Steel

Bowl: 316L, 304, Carbon Steel

O-Rings: Silicone, Viton or

EPDM (standard)

Orientation

Side-in/ Side-out (Standard)

Bottom-in/ Bottom-out (optional)

Connections

Inlet/Outlet : Flange

Vent/Drain : FNPT

Optional Features

• Inlet/outlet orientation:

Ergonomically superior Side-in

Side-out (standard) or Bottom-in

Bottom-out (optional)

• Epoxy coating, electro-polish

and fuse, or Teflon coating

• Low pressure drop, positive cover

seal• Higher pressure ratings available

up to 3,000 psi

• Easily cleaned • Variety of lid-lifting devices -

hydraulic, jack, or manual wheel

davit

• Stainless Steel perforated

baskets (standard)• Jacketing

• ASME code stamp available • Sanitary construction

• Swing bold closures • Wire mesh support baskets

• 1" to 2" NPT drain port on bottom • Mesh-lined basket for straining

applications - 50 micron and

higher

• .5" to 1" NPT pressure gauge/vent

tap• Differential pressure gauge taps

• Pipe sizes from 2" to 14" RFF

connections

• Davit lift

• Compression Device

Standard Features

Housing

Construction

Multi Bag

Option

Inlet/Outlet

Size (inch)

Fitting

StyleMaterial Other Options

2 = 2 Bags 2 F = Flange A =Carbon Steel GT = Gauge Taps

SRM 3 = 3 Bags 3 B = 304 SS MB4 = Mesh Basket 304 SS

4 = 4 Bags 4 C = 316 SS MB6 = Mesh Basket 316 SS

5 = 5 Bags 6 PC = Powder Coat for CS

6 = 6 Bags 8 SSS = SS Swing Bolts

8 = 8 Bags 10 U = ASME Code

10 = 10 Bags 12

12 = 12 Bags 14

Custom

Example - a 3 bag 304SS SRM bag filter housing,size #2, with a 3" flange is SRM-3-3F-B

SRM Bag Filter Housing Ordering Guide

Page 203

Page 205: ZenPure - Q-Test

ZenPure Portable Bag Filter Cart

Zen

Pu

re

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

H74 Rev 2011.07

®

Portable bag filter carts are ideal for those who need

filtration at several location but don’t have the foot-

print space for fixed filtration units. It also is ideal for

filtration testing to prove the benefits of filtration

without the permanent commitment of installing fil-

tration equipment.

These carts can be sold with or without the pump ena-

bling the using to select the ideal pump for their appli-

cation. A turn-key system complete with factory in-

stalled pumps chosen for your unique application is

readily available

The bag filter carts are designed to offer customers the

greatest flexibility to handle a variety of application

throughout a manufacturing facility. Available in two

or four wheel designs, these units are the perfect

choice for station to station, or remote location filtra-

tion applications. Materials of Bag Filter Housing

Carbon Steel

304 Stainless Steel

316 Stainless Steel

Housing Sizes

1, 2, 30, 65

Pumps

Specified by customer or application

Electric, Pneumatic, Impellor,

Bellows, Diaphragm, others

Options

Heavy Duty Wheels - two or four

Epoxy, Teflon or Fuse Coating

ASME Code Stamp

Two or more vessels configured in

parallel or series

Differential pressure gauges

others

Features Benefits

Portable Can be utilized in more than

one location

Complete Prefabricated

System

Comes from the factory ready

to plug in to your system and

filter

Customizable Designed to the customers

specification to meet their

needs

Page 204

Page 206: ZenPure - Q-Test

ZenPure Industrial High Purity Vent Filter Housing

Zen

Pu

re

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

H75 Rev 2011.07

®

The industrial high purity stainless steel vent housing is

constructed of 316L stainless steel for high purity appli-

cations to allow venting of large and small tanks. The

housing is typically used in the food and beverage in-

dustries. The housing comes in 10" to 40" sizes to meet

the needs of your application. The housing is a clean and

easy way to provide filtered air into tanks as well as al-

lowing gasses to flow out.

The housing can support 222 and 226 o-rings and Code

F, double open-ended filters. The design of the housing

provides for a positive seal with the filters, thereby, pre-

venting fluid bypass. The unique design for Code F

filters allows for cost saving and ease of installation. The

housing is attached by the use of a flange on the inlet

and a tri-clamp, or FNPT fitting, on the outlet.

Customization available upon request.

Materials of Construction

Head: 316L Stainless Steel

Bowl: 316L Stainless Steel

Clamp: 304 Stainless Steel

Center Post with Seal Plate: 316L SS

O-Rings: Silicone, Viton or EPDM

Dimensions (nominal)

Lengths (in): 10 , 20, 30 and 40

Connections

Inlet/ Outlet : Tri-clamp, Flange, FNPT

Vent / Drain : Tri-clamp, FNPT

Finish

Exterior: Bead Blast, Electropolish

Operating Conditions

Max operating pressure:

125 psi (10 bar) at 200°F (93°C)

Test Pressure :

165psi (11.4 bar) at 75°F (24°C)

Industrial High Purity Vent Filter Housing Ordering Guide

Applications

Fine Chemicals Ink Jets

Plating Solutions Electronics

Process Water Pharmaceuticals

Beverages Biologics

ConstructionNumber of

F iltersConfiguration Length

Cartridge

CodeInlet Connection Outlet Connection

Gasket

MaterialInterior/Exterior F inish

IHP = Industrial 1 = 1 Filter IV = In-Line Vent 1=10" 1 = DOE 3/4F = 3/4" Flange 1 1/2TC = 1 1/2" Tri-clamp E = EPDM BBP = Bead Blast & Passivate

High Purity 2=20" 7 = 2-226 1 1/2NPT = 1 1/2" FNPT V = Viton EP = Electropolish

3=30" 8 = 2-222 S = Silicon

4=40"

Example - 10" for a 222 filter, In-line with 3/4" inlet Flange, and 1.5"outlet Tri-clamp, EPDM Gasket and Electropolished is IHP1IV183/4F11/2TCEEP

Page 205

Page 207: ZenPure - Q-Test

Sanitary Stainless Steel Vent Housing

ZenPure Z

en

Pu

re

Features Benefits ■ Wide Chemical & Thermal Compatibility ■ Provides excellent compatibility with a wide range of

chemicals

■ The electropolished finish eliminates possible contamination

that could potentially leach into the process chemicals.

■ Tri-clamp ■ The housing allows for inspection of the filter before the housing

is sealed.

■ Easy filter change-out

Applications

Fine Chemicals Ink Jets

Plating Solutions Electronics

Process Water Pharmaceuticals

Beverages Biologics

ZenPure® sanitary stainless steel vent housing is constructed

of 316L stainless steel for high purity applications to allow

venting of large and small tanks. The housing comes in 5"

to 30" sizes to meet the needs of your application. The de-

sign provides a clean and easy way to provide filtered air

into tanks as well as allowing gasses to flow out.

The housing can support filters with 2-226 o-rings. It pro-

vides a positive seal on the filters that will prevent any par-

ticulate bypass. The housing is sealed by the use of a tri-

clamp that requires no special tools to open or close.

Materials of Construction

Head: 316L Stainless Steel

Bowl: 316L Stainless Steel

Clamp: 304 Stainless Steel

O-Rings: Silicone, EPDM,

Viton, PTFE

Dimensions (nominal)

Lengths: 5 in., 10 in., 20 in., 30 in.,

Width: 5.51 in. (140mm)

Connections

Inlet/ Outlet: 1.5" Sanitary Fitting

Finish

Electropolished

Operating Conditions

Max operating pressure: 145 psi (10 bar)

Atmospheric Tank Vent Housing

Page 206

Page 208: ZenPure - Q-Test

ZenPure Sanitary Stainless Steel Vent Housing

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

H76 Rev 2011.07

Sanitary Stainless Steel Vent Housing Ordering Guide

Nominal Length H (Bowl Height)

5" 185mm (7.28")

10" 305mm (12.0")

20" 555mm (21.85")

30" 805mm (31.69")

Housing

ConstructionMaterial Cartridge #

Cartridge

CodeLength CONNECTION Gasket Materials

SV = Sanitary P = 316L 01 = 1 Round 7 = 2-226 05 = 5" = 1.5" Tri-clamE = EPDMVent Filter 10 = 10" Sanitary Fitting S = SiliconeHousing 20 = 20" V = Fluoro-elastomer

30 = 30" F = PTFEExample - 10" Sanitary SS Vent Housing with Silicon gasket for Code 7 filter with1.5" Sanitary connection - SVP01710CS

Page 207

Page 209: ZenPure - Q-Test

Sample and Vent Valves

ZenPure Z

en

Pu

re

®

The sample and vent valves for stainless steel filter housings are

engineered for cleanliness and ease of use. The valves are con-

structed of 316L stainless steel for excellent resistance to corrosive

chemicals and to ensure product purity. They are machined to a

<20Ra finish. Each valve comes with it's own serial number,

material certificates and certificate of compliance.

The valves come in both in-line and 90 degree models. Additional

assemblies come with a pressure gauge, tee fitting and valve for

ease of use. The output fitting on the valve is a hose barb to make

quick attachments with a hose to vent or take samples. The design

of the unit minimizes dead space for possible contamination build-

up between usage. The valve has a limited stem travel for safety

and valve protection. The knob is made out of Delrin®, a material

from DuPont, which is durable, low wear, low friction plastic, ideal

for this application.

The newest release are the inline sampler with a constant flow

throw purge. The liquid is pulled from the middle of the stream

for sampling. The sample tube is constantly being flushed

through by the moving fluid pressure and exiting a small hole on

the down stream side right before the Ferrule, NPT or Weld con-

nection to the tubing.

Materials of Construction

Body: 316L Stainless Steel

Knob: Solid Delrin Knob

O-Rings: Silicone, Teflon (optional)

Connections

Inlet: Tri-clamp, Ferrule, NPT, Butt Weld

Outlet: 3/8" Hose Barb

Finish

Machined <20Ra

Operating Conditions

Max operating pressure: 400 psi (27 bar)

at 200°F (93°C)

Applications Filter Housings Tanks

Product Sampling Product testing

Pressure Vessels Day Tanks

Example: Cross section of pipe with flow through purge valve

PN # OFSVILF Inline 1/2" Tri-clamp

PN # OFSVILF1.13 EXT Inline 1/2" Tri-clamp with 1

1/8” Extension

A few examples of options - See back for more details

Page 208

Page 210: ZenPure - Q-Test

ZenPure Sample and Vent Valves

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

H77 Rev. 2011.07

IN-LINE WELD

2.40"

IN-LINE 1/4" NPTIN-LINE 1/2" FERRULE

1.16"Ø

90° 1/2" FERRULE90° 1/4" NPT 90° 1/2" WELD

2.05"

1.31"

1/4" HOSE

BARB

P/N OFSV90F

P/N OFSVILF P/N OFSVILN

P/N OFSV90N P/N OFSV90W

P/N OFSVILW

SANITARY VALVE

1/4" MACHINED TEE

WIKA INDUSTRIAL GAUGE 2" Ø GLYCERINE FILLED

1/4" HALF COUPLING

SANITARY VALVE

WIKA MODEL M93X.2A 2 1/2" Ø SANITARY GAUGE

GLYCERINE FILLED

0 160 1 1/2" SANITARY SPOOL WITH (2) CLAMPS & (2) SILICONE GASKETS

1 1/2" FERRULE

Additional Assembly Options

Industrial Pressure Gauge and Vent

Valve Assembly

P/N IGAOFSVILN

P/N SGAOFSVILW

Sanitary Pressure Gauge and Vent

Valve Assembly

100-160 PSI Pressure Gauge

316L Stainless Steel

Sanitary Vent/Sample Valve

Machined 1/4" NPT Tee

100-160 PSI Pressure Gauge

316L Stainless Steel

Sanitary Vent/Sample Valve

1 1/2" Electropolished Tri-Clamp Spool

(2) Silicone Gaskets & (2) SS Clamps

PART NUMBER  VALVE DESCRIPTION

 OFSVILF  Inline 1/2" Ferrule

 OFSVILF-1.13EXT

 Inline 1/2" Ferrule w/ 1 1/8" Stem Extension for

1 1/2" & Smaller Tube Run

 OFSVILF-2EXT

 Inline 1/2" Ferrule w/ 2" Stem Extension for 2"

& Larger Tube Run

 OFSV90F  90 Degree 1/2" Ferrule

 OFSVILF-1  Inline 1 - 1 1/2" Ferrule

 OFSVILF-1-1.13EXT

 Inline 1 - 1 1/2" Ferrule w/ 1 1/8" Stem

Extension

 OFSVILF-1-2EXT  Inline 1  - 1 1/2" Ferrule w/ 2" Stem Extension

 OFSV90F-1  90 Degree 1 - 1 1/2" Ferrule

 OFSVILF-2  Inline 2" Ferrule

 OFSVILF-2-1.13EXT  Inline 2" Ferrule w/ 1 1/8" Stem Extension

 OFSVILF-2-2EXT  Inline 2" Ferrule w/ 2" Stem Extension

 OFSV90F-2  90 Degree 2" Ferrule

 OFSVILN  Inline 1/4" NPT

 OFSVILN-1.13EXT  Inline 1/4" NPT w/ 1 1/8" Stem Extension

 OFSVILN-2EXT  Inline 1/4" NPT w/ 2" Stem Extension

 OFSV90N  90 Degree 1/4" NPT

 OFSVILW  Inline Weld Body

 OFSVILW-1.13EXT  Inline Weld Body w/ 1 1/8" Stem Extension

 OFSVILW-2EXT  Inline Weld Body w/ 2" Stem Extension

 CUSTOM CONFIGURATIONS OF 90 DEGREE VALVES W/

Page 209

Page 211: ZenPure - Q-Test

Sanitary Y-Strainer

ZenPure Z

en

Pu

re

®

The sanitary Y-Strainer is constructed of 316L stainless steel for

excellent resistance to corrosive chemicals and to ensure product

purity. The strainer is utilized in the food and beverage industry

to remove impurities from the liquid stream.

We offer a complete line of strainers that range from 1.5" to 6"

inlet/outlet with sanitary, flange or I-Line union connections to

fit your flow rates. The wellscreen design is durable and can

handle high differential pressure without failure. The Y-style

makes for easy servicing without removing the entire unit, sav-

ing time and effort. The large sightglass allows for easy viewing

of the upstream (dirty) wellscreen surface.

Customization of the housing is available. Materials of Construction

Body: 316L Stainless Steel

Siteglass: Glass

Clamp: 304 Stainless Steel

Gasket: Silicone, Viton or EPDM

Wellscreen: 316L Stainless Steel

Connections

Inlet/Outlet : Tri-clamp, Flange and

I-Line Union

Sizes (in): 1.5, 2, 3, 4, 6

Finish

Interior/Exterior: Bead Blast and Passivate, or

Electropolished

Operating Conditions

Max operating pressure:

125 psi (10Bar) at 200°F (93°C)

Test Pressure :

165psi (11.4 Bar) at 75°F (24°C)

Applications

Food & Beverage Ink Jets

Fine Chemicals Electronics

Plating Solutions Pharmaceuticals

Process Water Parts Cleaning

Features Benefits

■ Wide Chemical & Thermal Compatibility ■ Provides excellent compatibility with a wide range of

chemicals

■ The electropolished finish eliminates possible contamination

that could potentially leach into the process chemicals

■ Y - Design ■ For quick change out, and ease of use

■ Provides the ability to put the strainer into a straight line of

pipe

■ Siteglass ■ Allows the user to see the wellscreen and particulate matter

without opening the housing

■ Prevents unnecessary contamination of the fluid stream

Picture of Internal WellScreen

Page 210

Page 212: ZenPure - Q-Test

ZenPure Sanitary Y-Strainer

ZenPure

Your Local Distributor:

ZenPure and PureFlo are registered trademarks of ZenPure Corporation or an affiliated company

Copyright 2003-2012 ZenPure or an affiliated company All rights reserved

North & South Americas: ZenPure Americas, Inc www.zenpure.com [email protected] 703-335-9910

All Other Regions: ZenPure Corporation www.zenpure.com [email protected] +86 571 2288 6800

H79 Rev. 2011.07

TRICLAMP

O-RING SEAL

HANDLE

WELLSCREEN

GASKET

INLET

ISOMETRIC

VIEW

OUTLET

SIGHTGLASS

ASSEMBLE

(QTY 2)

Sanitary Y-Strainer Ordering Guide

Outside to Inside Flow

ConstructionInlet/Outlet

F itting Size

Inlet/Outlet

F itting Style

Strainer Slot

Size

Gasket

MaterialInterior/Exterior F inish

SYS = Sanitary 1.5 = 1.5" TC = Tri Clamp E = EPDM BBP = Bead Blast & Passivate

Y-Strainer 2 = 2" F = Flange V = Viton EP = Electropolish

3 = 3" I = I-Line Union S = Silicon

4 = 4"

6 = 6"

***M - Pick

U.S. Mesh Size

from Table

Example - Y- Strainer with 2" flange fitting with a 100 mesh stainer, EPDM gasket and electropolished is SYS2F100MEEP

U.S Mesh Inches Microns Millimeters

3 0.2650 6730 6.730

3.5 0.2230 5660 5.660

4 0.1870 4760 4.760

5 0.1570 4000 4.000

6 0.1320 3360 3.360

7 0.1110 2830 2.830

8 0.0937 2380 2.380

10 0.0787 2000 2.000

12 0.0661 1680 1.680

14 0.0555 1410 1.410

16 0.0469 1190 1.190

18 0.0394 1000 1.000

20 0.0331 840 0.840

25 0.0280 707 0.710

30 0.0232 595 0.590

35 0.0197 500 0.500

40 0.0165 420 0.420

45 0.0138 354 0.350

50 0.0117 297 0.297

60 0.0098 250 0.250

70 0.0083 210 0.210

80 0.0070 177 0.177

100 0.0059 149 0.149

120 0.0049 125 0.125

140 0.0041 105 0.105

170 0.0035 88 0.088

200 0.0029 74 0.074

230 0.0024 63 0.063

270 0.0021 53 0.053

Y- Strainer Slot Size

Page 211

Page 213: ZenPure - Q-Test

ZenPure Z

enP

ure

BENEFITS OF ELECTROPOLISHING STAINLESS STEEL PRODUCTS

The Electro polishing process creates a super Passivated finish. This finish protects the material from corrosive environments, while adding the benefit of improving the luster and the finish of the smoothness of the item. A surface may be enhanced to the point it becomes non-particulating. An easy solution for most stainless steel finishing needs. Benefits of the electropolishing process:

CORROSION RESISTANCE Removes impurities which leaves a homogenous metal surface. Salt spray tests show an EP’ d surface is 4 - 5 times more resistant to corrosion. long enough. APPEARANCE EP vastly improves the finish of most series of stainless steel. There is no other finish that can create such a brilliant ef-fect. SUPER CLEANING EP’d surfaces are stain and bacteria resis-tant. This benefit makes electro polishing a great solution for the food, beverage, chemical and pharmaceutical industries. LONGEVITY Metal that has been through the Electro Polishing process, has be been stress relieved. This improves the fatigue strength of the metal.

MICROFINISHING A normal EP process will improve micro finish to a factor of 2. A part with a 40 RA can be reduced to a 20 RA if exposed long enough. DEBURRING Many parts are too fragile or heavy for tumbling have deep recesses, that make mechanical de-burring almost impossible. EP is a cost effective way to enhance your product and remove these burrs.

Page 212

Page 214: ZenPure - Q-Test

Symbolic

Rating

A <10% in 30days to 1 year <15% in 30days to 1 year <15% in 30days to 1 year <15% in 30days to 1 year

B <15% in 30days to 1 year <30% in 30days to 1 year <30% in 30days to 1 year <30% in 30days to 1 year

C <20% in 30days to 1 year <50% in 30days to 1 year <50% in 30days to 1 year <60% in 30days to 1 year

NR >20% immediately to 1 year >50% immediately to 1 year >20% immediately to 1 year >60% immediately to 1 year Sever - attack, swelling, and softening. Not recommended.

INTERPRETATION OF DATA

Excellent - little or no swelling, softening or surface deterioration.

Good - Minor swelling, softening or surface deterioration.

Limited - Moderate chemical attack. Conditional service.

Linear (Plastics) Volumetric (Elastomers)

Description of Chemical Resistance

(Plastics) (Elastomers)

Swelling Loss of Tensile Strength

Chemical Name Formula Viscosity (cp)

Surface

Tension

(dynes/cm)

PTFE PVDF Polypropylene Nylon PES Viton Silicon Buna N EPDM TEV TESPureFlo

PTFE

PureFlo

PVDFPureFlo PP

Melt Blown

PPPureFlo Nylon Pureflo PES

Acetic Acid (glacial) C2H4O2

5% 20C 1.1cp

50% 20C 2.2cp

80% 20C 2.7cp

100% 20C 1.2cp

50C 0.796cp

29.3 @25C A A to 122º F A to 100º F NR A to 70º F NRA 30% to

70º FNR A to 100º F A A A to 100º F A to 100º F A to 100º F A to 100º F NR A to 70º F

Acetone CH3C0CH30C 0.391cp

20C 0.318cp26.2 A NR A to 230º F A to 70º F NR NR C @ 100º F NR A to 200º F A A A to 230º F NR A to 230º F A to 230º F A to 70º F NR

Alcohols, General A A to 275º F AB to 70º F A to 70º F Variable AB to 200º F NR AB to 100º F AC to 70º F A A AB to 70º F AB to 70º F AB to 70º F AB to 70º F AB to 70º F Variable

Amines, General A NR AB to 120º F A to 70º F NR BC to 70º F NR AC to 70º F A A AB to 120º F NR AB to 120º F AB to 120º F A to 70º F

Ammonium Fluoride NH4F 40% 20C 4cp 95 A A to 280º F A to 225º F AB to 70º F A to 140º F A to 70º F AB to 70º F A to 140º F A A A to 225º F A to 225º F A to 225º F A to 225º F AB to 70º F

Ammonium

HydroxideNH4OH

10% 20C 1.1cp

28% 20C 1.2cp

54% 20C 1.3cp

62 A A to 200º F A to 225º F AC to 122º FA to 20% to 70º

FAB to 190º F A to 70º F

A38% to

200º FA to 160º F A A A to 225º F A to 225º F A to 225º F A to 225º F AC to 122º F

A to 20% to

70º F

Ammonium

PersulfateA A to 260º F A to 225º F NR AB to140º F NR NR A to 70º F A A A to 225º F A to 225º F A to 225º F A to 225º F NR

Ammonium

PhosphateNH4x(PO4)y A A to 280º F A to 225º F AB to 70º F AB to180º F A to 70º F NR A to 70º F A A A to 225º F A to 225º F A to 225º F A to 225º F AB to 70º F

Ammonium Sulfate

(Dolamin)A A to 280º F A to 225º F AB to 70º F A to 176º F A to 70º F A to 200º F A to 300º F A A A to 225º F A to 225º F A to 225º F A to 225º F AB to 70º F

Aqua Regia

(NitroHydrochloric

Acid)

~80%HCL +

20%HNO3A A to 100º F C @70º F NR AB to 190º F NR NR BC to 70º F A A C @70º F C @70º F C @70º F C @70º F NR

Beer A A to 250º F A to 200º F A to 70º F A to 70º F A to 176º F A to 70º F A to 140º F A to 140º F A A A to 200º F A to 200º F A to 200º F A to 200º F A to 70º F A to 70º F

Boric Acid H3BO3 A A to 280º F A to 225º F NR A to 70º F A to 185º F A to 70º F A to 140º F A to 176º F A A A to 225º F A to 225º F A to 225º F A to 225º F NR A to 70º F

Butyl AcetateCH3COO(CH2)3

CH3

20C 0.734cp

25C 0.688cp

24.9 @ 25C A A to 70º F NR A to 200º F B @ 70º F NR NR NR BC to 70º F A A NR NR NR NR NR NR

Butyl Alcohol C4H9OH20C 2.948cp

30C 2.30cp27 A A to 275º F AB to 180º F AB to 120º F A to 70º F A to 250º F A to 70º F A to 140º F A to 185º F A A AB to 180º F AB to 180º F AB to 180º F AB to 180º F AB to 120º F A to 70º F

Carbon Tetrachloride CCl420C 0.97cp

25C 0.793cp29.5 A AB to 150º F NR A to 200º F AB to 212º F A to 250º F NR NR NR A A NR NR NR NR NR NR

Chrome Plating

SolutionsA A to 260º F AC to 70º F NR A to 70º F B to 70º F NR B to 70º F A A AC to 70º F AC to 70º F AC to 70º F AC to 70º F NR

Citric Acid C6H8O7 A A to 275º F A to 180º F NR A to 70º F A A A A A A A to 180º F A to 180º F A to 180º F A to 180º F NR A to 70º F

Copper Sulfate &

H2SO4

Copper Sulfate &

H2SO42 A A to 275º F A to 225º F AC to 140º F A to 70º F A to 140º F NR B to 70º F A to 250º F A A A to 225º F A to 225º F A to 225º F A to 225º F AC to 140º F A to 70º F

Cyclohexanone C6H10O 2.4 @15C 38 A AB to 122º F BC @70º F A to 70º F NR NR NR NR NR A A BC @70º F BC @70º F BC @70º F BC @70º F BC @70º F NR

DI Water

(20C)H2O

20C:1.0cp, 50:

0.6cp,

100C:0.3cp

72 A A A A A to 70º F A A A A A A A A A A A A to 70º F

DI Water (HOT)

(80C)H2O

20C:1.0cp, 50:

0.6cp,

100C:0.3cp

62.6 A A to 280º F A to 225º F NR A A A A to 225º F A to 225º F A to 225º F A to 225º F NR A to 225º F

Dichloroacetic Acid CL2CHCO2H A AB to 125º F AB to 125º F NR NR NR NR NR A A AB to 125º F AB to 125º F AB to 125º F AB to 125º F NR

Filter Recommendation CHEMICAL Filter Material (Plastics) Oring Material (Elastomers)

Chemical Compatibility Table For ZenPure Filtration Products ZenPure

Page 213

Page 215: ZenPure - Q-Test

Chemical Name Formula Viscosity (cp)

Surface

Tension

(dynes/cm)

PTFE PVDF Polypropylene Nylon PES Viton Silicon Buna N EPDM TEV TESPureFlo

PTFE

PureFlo

PVDFPureFlo PP

Melt Blown

PPPureFlo Nylon Pureflo PES

DiMethyl Formamide

(DFM)HCON(CH3)2

20C 0.845cp

50C 0.598cp

36.7 @ 20C

34.4 @ 40CA NR A to 125º F A to 70º F NR NR BC to 70º F NR C to 70º F A A A to 125º F NR A to 125º F A to 125º F A to 70º F NR

Dimethylsulfoxide

(DSMO)CH3SOCH3 20C 2.14cp 43 A NR A to 125º F A to 70º F NR NR A to 70º F C to 70º F A to 70º F A A A to 125º F NR A to 125º F A to 125º F A to 70º F NR

Ethyl Acetate (Acetic

Ether)CH3COOC2H5

15C 0.473cp

20C 0.45cp

25C 0.426cp

23.4 @ 25C A A to 70º F A to 225º F A to 122º F NR NR B to 70º F NR A to 130º F A A A to 225º F A to 70º F A to 225º F A to 225º F A to 122º F NR

Ethyl Alcohol C2H5OH20C 1.200cp

30C 1.003cp24 A A to 275º F AB to 70º F A to 70º F Variable B to 70º F

AB to 200º

FA to 140º F A to 200º F A A AB to 70º F AB to 70º F AB to 70º F AB to 70º F AB to 70º F Variable

Ethylene Glycol CH2OHCH2OH

26 cp @ 15C

21 cp @ 20 C

17.3 cp @ 25 C

A A to 260º F A to 225º F A to 70º F A to 212º F A to 200º F A to 250º F A to 250º F A to 250º F A A A to 225º F A to 225º F A to 225º F A to 225º F A to 70º F A to 212º F

Ferrous Sulfate FeSO4 A A to 275º F A to 225º F NR A to 70º F A to 176º F B to 70º F A to 160º F A to 176º F A A A to 225º F A to 225º F A to 225º F A to 225º F NR A to 70º F

Formic Acid (Formylic

Acid)CH2O2 A A to 214º F A to 70º F NR A to 70º F NR B to 70º F B to 70º F A to 210º F A A A to 70º F A to 70º F A to 70º F A to 70º F NR A to 70º F

Freon 13 A A to 200º F Variable A to 70º F A to 70º F AB to 70º F NR A to 70º F A to 70º F A A Variable Variable Variable Variable Variable Variable

Hexane C6H14 A A to 275º F B/NR @ 70º F A to 70º F A to 70º F A to 200º F NR A to 250º F NR A AB/NR @ 70º

FB/NR @ 70º F B/NR @ 70º F B/NR @ 70º F B/NR @ 70º F

B/NR @ 70º

F

Hydrobromic Acid

(Hydrogen Bromide)HBr A A to 275º F C/NR @ 70º F NR A to 70º F A to 70º F NR A to 200º F A A

C/NR @ 70º

F

C/NR @ 70º

FC/NR @ 70º F

C/NR @ 70º

FNR

Hydrochloric Acid

(Muriatic Acid)HCL

10% 20C 1.1cp

38% 20C 2.1cpA A 50% @ 175º F A to 70º F NR

A 50% to 140º

FA to 70º F NR NR BC to 70º F A A A to 70º F A to 70º F A to 70º F A to 70º F NR A to 70º F

Hydrofluoric Acid HF5% 1cp

49% 1cpA A 50% @ 175º F

A to 40% @ 200º

FNR C60% @ 70º F NR NR C to 70º F A A

A to 40% @

200º F

A to 40% @

200º F

A to 40% @

200º F

A to 40% @

200º FNR

Hydrogen Peroxide H2O2 30% 20C 1cp AA to 200ºF

AB50% to 250ºF

A 80%H2O2 to 70º F

A 5%H2O2 to170º F

B/NR100% @70º F

NR A to 70º F NR B to 70º F NR BC to 70º F A A B/NR @70º F B/NR @70º F B/NR @70º F B/NR @70º F NRB/NR @70º

F

Ink A A to 70º F A to 180º F AB to 70º F A to 70º F A to 140º F A to 70º F A A A to 180º F A to 70º F A to 180º F A to 180º F AB to 70º F

Iodine I2 A A to 170º F A to 75º F NR A to 190º F NR B to 70º F C to 70º F A A A to 75º F A to 75º F A to 75º F A to 75º F NR

Isopropyl Alcohol

(IPA)C3H8O

15C 2.86cp

20C 2.5cp

30C 1.77cp

22 A A to 150º F A to 225º F AB to 70º F A to 70º F A to 170º F A to 160º F A to 70º F A to 160º F A A A to 225º F A to 150º F A to 225º F A to 225º F AB to 70º F A to 70º F

Methyl Alcohol

(Methanol)CH3OH

20C .597cp

25C .547cp

30C .510cp

22 A A to 148º F A to 70º F NR A to 70º F NR A to 70º F A to 70º F A to 160º F A A A to 70º F A to 70º F A to 70º F A to 70º F NR A to 70º F

Methylene Chloride CH4Cl2

15C .449cp

20C .42cp

30C .393cp

26 A AB to 100º F NR BC to 70º F NR C to 70º F NR NR NR A A NR NR NR NR NR NR

Mineral Spirits A A to 275º F A to 100º F A to 105º F A to 250º F NR A to 250º F NR A A A to 100º F A to 100º F A to 100º F A to 100º F A to 100º F

Nickel Choride NiCl2-6H2O A A to 275º F AB to 180º F NR A to 212º F A to 160º F A to 176º F A to 176º F A A AB to 180º F AB to 180º F AB to 180º F AB to 180º F NR

Nickel Sulfate NiSO4-6H2O A A to 275º F A to 225º F AB to 70º F A A to 160º F A to 176º F A to 176º F A A A to 225º F A to 225º F A to 225º F A to 225º F AB to 70º F

Nitric Acid HNO3 40% 20C 1.6cp ANR 100% @70ºF

AC 50% @ 160ºF

NR 80% @70ºF A

50% @ 104ºFNR NR NR NR NR NR A A

NR 80%

@70ºF A

50% @ 104ºF

NR 80%

@70ºF A 50%

@ 104ºF

NR 80%

@70ºF A 50%

@ 104ºF

NR 80%

@70ºF A 50%

@ 104ºF

NR NR

NMP (N-Methyl 2-

Pyrrolidone)CH3N(CH2)3CO 25C 1.66cp

41@20C

33-36@80CA NR A to 70º F NR AB to 70º F A to 70º F A A NR NR

Oxalic Acid

(Ethanedioic Acid)C2H2O4 A AB to 150º F A to 140º F NR A to 70º F A to 250º F B to 70º F B to 70º F A to 300º F A A A to 140º F AB to 150º F A to 140º F A to 140º F NR A to 70º F

Ozonated DI Water 1cp A A to 230º F NR A to 70º F C to 70º F B to 70º F NR A to 70º F A A NR

Ozone O3 A A to 230º F C/NR @ 70º F NR A to 70º F A to 70º F A NR A to 70º F A AC/NR @ 70º

F

C/NR @ 70º

FC/NR @ 70º F

C/NR @ 70º

FNR

C/NR @ 70º

F

Phosphoric Acid

(85%@120-160C)H3PO4

85% 120C 5cp

85% 160C 3cp A A 85% @316º F NR NR A to 212º F NR NR NR NR A A NR NR NR NR NR NR

Phosphoric Acid

(85%@20C)H3PO4 85% 20C 49cp A A 85% @316º F A to 185º F NR A to 212º F A to 158º F NR NR A to 158º F A A A to 185º F A to 185º F A to 185º F A to 185º F NR A to 185º F

Potassium Hydroxide

(36%)KOH 3.1cp ~90 A A to 167º F A to 180º F AB to 70º F

A 50% to 212º

FNR C to 70º F AB to 150º F A to 210º F A A A to 180º F A to 167º F A to 180º F A to 180º F A to 180º F A to 180º F

Potassium

PermanganateKMNO4 A A to 250º F A to 70º F NR A20% @160º F C to 70º F A to 200º F A A A to 70º F A to 70º F A to 70º F A to 70º F NR

Filter Recommendation CHEMICAL Filter Material (Plastics) Oring Material (Elastomers)

Page 214

Page 216: ZenPure - Q-Test

Note:

The compatibility data was assembled from the Chemical Resistance Guide published by COMPASS PUBLICATIONS© This table is to be used for a general guide only. ZenPure is

not responsible for the accuracy of this data and assumes no obligation of liability in connection with its use. ZenPure recommends that all customers evaluate and test the suitability

for use of filters in their particular application before using.

ZenPure and PureFlo are registered trademarks of ZenPure Corporation. Viton® is a registered trademark of Dupont Dow Elastomer

To convert from Fahrenheit to Celsius:

°C=(5/9) x (°F-32)

To convert from Celsius to Fahrenheit:

°F =(9/5)°C+32

Chemical Name Formula Viscosity (cp)

Surface

Tension

(dynes/cm)

PTFE PVDF Polypropylene Nylon PES Viton Silicon Buna N EPDM TEV TESPureFlo

PTFE

PureFlo

PVDFPureFlo PP

Melt Blown

PPPureFlo Nylon Pureflo PES

Pyridine (Azine) C5H5N A NR A to 75º F A to 70º F NR NR NR NR B to 70º F A A A to 75º F NR A to 75º F A to 75º F A to 70º F NR

SC1 (40-90C) NH4OH + H2O2 0.65 72 A A to 200º FA 80%H2O2 to 70º F

A 5%H2O2 to170º F NR

A20%H2O2 to 70º

FNR B to 70º F NR BC to 70º F A A

A80%H2O2 to

70º F

A5%H2O2

to170º F

A80%H2O2 to

70º F A5%H2O2

to170º F

A80%H2O2 to

70º F A5%H2O2

to170º F

A80%H2O2 to

70º F A5%H2O2

to170º F

NRA20%H2O2 to

70º F

SC2 (25-90C)HCL + H2O2 +

H201 72 A

A 50%HCL @ 175º

F

A 80%H2O2 to 70º F

A 5%H2O2 to170º F NR

A 50%HCL to 140º

F A20%H2O2 to

70º F

NR NR NR BC to 70º F A A

A80%H2O2 to

70º F

A5%H2O2

to170º F

A80%H2O2 to

70º F A5%H2O2

to170º F

A50%HCL @

175º F

A80%H2O2 to

70º F A5%H2O2

to170º F

A80%H2O2 to

70º F A5%H2O2

to170º F

NR

A50%HCL to

140º F

A20%H2O2 to

70º F

Silane (Liquid)

N-[3-

(trimethoxysilyl)pr

opyl]-1,2-

ethanediamine

A A to 70º F A to 70º F A A A to 70º F A to 70º F A to 70º F A to 70º F

Silicon Tetrachloride SiCl4 A A to 160º F A to 100º F NR NR NR NR A A A to 100º F A to 100º F A to 100º F A to 100º F

Sodium Chloride

(Salt)NACL A A to 175º F A to 225º F A to 70º F A to 70º F A to 212º F A to 70º F A to 160º F A to 176º F A A A to 225º F A to 175º F A to 225º F A to 225º F A to 70º F A to 70º F

Sodium Hydroxide

(Caustic Soda)NAOH

5% 20C 1.3cp

20% 20C 4.6cp

40% 20C 36.2cp

50% 20C 80cp

36%: 101 AA 20% @104ºF

NR 70% @70ºFA 70% @180ºF A to 70º F A 54% @70ºF AB to 70º F A to 70º F B to 70º F A to 130º F A A

A 70%

@180ºF

A 20%

@104ºF NR

70% @70ºF

A 70%

@180ºF

A 70%

@180ºF

A 70%

@180ºF

A 54%

@70ºF

Sodium Hypochlrite

(Bleach)CLNaO A AB to 275º F A to 70º F NR B to 70º F AB to 130º F B to 70º F NR A to 70º F A A A to 70º F A to 70º F A to 70º F A to 70º F NR B to 70º F

SPM (Piranha) (Caro)H2SO4 + H2O2

Ozonized Water A NR NR NR NR NR NR NR NR A A NR NR NR NR NR NR

Sulfuric Acid

(96%@20C)H2SO4

50% 20C 3.8cp

96% 20C 25.4cp

96% 50C 8.8cp

50% - 74

80% - 69

90% - 58

96%- 55

AA95% @180º F

NR100% @70º F

A95% @70º F

NR100% @70º FNR NR A to 158º F NR NR NR A A

A95% @70º

F NR100%

@70º F

A95% @70º F

NR100%

@70º F

A95% @70º F

NR100%

@70º F

A95% @70º F

NR100%

@70º F

NR NR

Sulfuric Acid

(96%@80C)H2SO4 96% 80C 5.2cp

50% - 71

80% - 69

90% - 58

96%- 55

A NR NR NR NR NR NR NR NR A A NR NR NR NR NR NR

Sulfuric Acid

(96%@120C)H2SO4 96% 120C 2cp

50% - 69

80% - 67

90% - 58

96%- 55

A NR NR NR NR NR NR NR NR A A NR NR NR NR NR NR

TMAH

(tetramethylammoniu

m hydroxide)

1cp A A to 200º F A to 150º F C to 70º F B to 70º F C to 70º F A to 70º F A A A to 150º F A to 150º F A to 150º F A to 150º F A to 150º F A to 150º F

Toluene C7H8

15C 0.623cp

20C 0.59cp

30C 0.523cp

27.9 @ 25C A A to 140º F NR A to 70º F NR AB to 200º F NR NR NR A A NR NR NR NR NR NR

Trichloroethylene

(Triad)C2HCl3

20C 0.566cp

25C 0.532cp30 A A to 189º F NR AB to 70º F NR A to 200º F NR NR NR A A NR NR NR NR NR NR

Xylene C8H1020C .617cp

40C 0.497cp28.4 @ 25C A A to 175º F C to 70º F A to 70º F B to 70º F AB to 200º F NR NR NR A A C to 70º F C to 70º F C to 70º F C to 70º F C to 70º F C to 70º F

Filter Recommendation CHEMICAL Filter Material (Plastics) Oring Material (Elastomers)

Page 215

Page 217: ZenPure - Q-Test

ZenPure

RE: TC-11003

ZenPure Corporation (USA)

ZenPure Americas, Inc. (USA)

ZenPure (Hangzhou) Co., Ltd.

TERMS AND CONDITIONS OF SALE

1. Acceptance: All orders are subject to approval and acceptance by Seller. A written acknowledgement sent to Buyer of orders so approved shall constitute such acceptance by Seller. Seller may at any time alter or suspend credit, refuse shipment, or cancel unfilled orders when, in Seller’s opinion, the financial condition of Buyer warrants it, or when delivery is delayed by fault of Buyer or Buyer is delinquent in any pay-ment. No order accepted by Seller will be subject to cancellations, termination, suspension, change, reduction, cutback, or any other modi-fications except with Seller’s prior written consent. Any such modifica-tions may be subject to a charge as determined by Seller. The terms of this contract shall supersede any conflicting terms contained on Buyer’s purchase order or any document or instrument submitted by Buyer. 2. Cancellation: Orders may be canceled or deliveries deferred only upon the condition the Buyer assumes immediate liability for and makes prompt payment to Seller of all expenses incurred, charges for commit-ments made by Seller, profit on work in process and contract value of items completed and ready for shipment. 3. Prices, Taxes, and Payment: All prices are firm unless otherwise agreed in writing. Seller reserves the right to change the prices and specifications of its Products at any time without notice. Any tax, duty, custom or other fee of any nature imposed upon this transaction by any international, export, import, federal, state or local governmental author-ity shall be paid by Buyer in addition to the price quoted or invoiced. In the event Seller is required to prepay any such tax, Buyer will reimburse Seller. Payment terms shall be net 30 days after shipment by Seller. 4. Delivery and Shipment: Seller will make every effort to ship the Products or provide the services hereunder in accordance with the requested date, provided, that Seller accepts no liability for any losses or for general, special or consequential damages arising out of delays in delivery. Shipment of all Products shall be F.O.B point of distribution by Seller. Identification of the Products shall occur when they leave Seller point of distribution, at which time title and risk of loss shall pass to Buyer. All shipment costs shall be paid by Buyer and if prepaid by Seller the amount thereof shall be reimbursed to Seller within thirty (30) days after notice of such payment to Buyer. 5. Inspection: Buyer shall inspect all items upon arrival and shall give written notice to Seller within ten (10) days of arrival of any claim for shortage or non-conformance with the terms hereof. If Buyer shall fail to give such notice, all items shall be deemed to conform with, and Buyer shall be bound to accept and pay for items in accordance with the terms hereof. 6. Returns: No product may be returned without Seller’s prior written approval. Transportation charges are to be prepaid by Buyer. Re-turned goods are subject to the Seller’s inspection and acceptance. Seller may, in its discretion, either (a) refund to Buyer the amount paid for the returned items, (b) repair the returned items or (c) replace one or all returned items within a reasonable time after Seller determines that the returned goods are not in accordance herewith, and in such event Seller shall not be liable for any damages arising from the defective delivery or delay caused thereby. When expressly authorized by Seller in writing, unused products may be returned to Seller subject to service handling, restocking charges and rebuilding charges to “as new” condi-tion. 7. Force Majeure: Seller shall not be liable for any delays in the deliv-ery of orders, due in whole or in part, directly or indirectly, to fire, act of God, strike, shortage of raw materials, supplies or components, retool-ing, upgrading of technology, delays of carriers, embargo, government order or directive, or any other circumstance beyond Seller reasonable control.

8. Indemnification Against Infringement: Buyer shall protect and indemnify Seller and its affiliates, directors, officers, agents and employ-ees against all claims for damages or profits, including all reasonable costs incurred by Seller in connection therewith, arising from infringe-ment of patents, copyrights, trademarks or misappropriation of designs, proprietary data or trade secrets of any person with respect to all goods manufactured either in whole or in part in accordance with Buyer’s specification. 9. Indemnification: Buyer shall indemnify and hold harmless Seller its affiliates, directors, officers, agents and employees from all loses, claims, damages, expenses or liabilities of any kind (including attorney’s fees and court costs) resulting from or arising out of any use by Buyer of the products purchased herein. 10. Repairs, Alterations, and Modification: Any repairs made to the products shipped by the Seller shall be at the expense of the Buyer unless specifically authorized by the Seller in writing. Alterations or modifications to the product involving welding, soldering, drilling, or machining by the Buyer are not permitted or approved by the Seller without specific authorization in writing by the Seller. Any unauthorized alteration or modification by the Buyer will void the warranty. 11. Warranty: Seller warrants its products against defects in workman-ship and material for a period of 12 months from the date of shipment from the factory or Seller distr butor under normal use and service and otherwise when such products are used in accordance with instructions furnished by Seller and for purposes disclosed in writing at the time of purchase, if any. Seller’s liability under this warranty shall be limited to repair or replacement, F.O.B point of distribution, of any defective prod-ucts or part which, having been returned to the factory, transportation charges prepaid, has been inspected and determined by the Seller to be defective.

This warranty is in lieu of any other warranty either expressed or im-plied, as to the merchantability, quality, description, and fitness for any particular purpose or use, or any other matter.

Under no circumstance shall the Seller be liable to Buyer or any other third party for any loss of profits or other direct or indirect costs, ex-penses, losses or consequential damages arising out of or as a result of any defects in or failure of its products or any part or parts thereof or arising out of or as a result of parts or components incorporated in Seller’s products but not supplied by the Seller. 12. Arbitration: Any and all disputes or controversies arising under, out of or in connection with this contract or the sale or performance of the products shall be resolved by final and binding arbitration in the State of Nevada. 13. General: No items to be furnished hereunder shall be exported by Buyer or by any customer of Buyer unless Seller is first notified in writing of the intention to so export and all applicable regulations and licenses are complied with and obtained by Buyer or its customer. Seller reserves the right to make changes in design at any time without incurring any obligation to make such changes in any items previously purchased, whether or not delivered. Seller expressly disclaims application of any government procurement regulations in connection with any items to be furnished hereunder unless expressly agreed to in writing by an authorized representative of Seller. Buyer understands that to the extent the goods are being shipped to the United States, the Seller’s sale of the product to Buyer are subject to U.S. export control laws and regulations and Buyer shall comply with all such laws and regulations.

Page 216

Page 218: ZenPure - Q-Test

ZenPure

RE: TC-11003

ZenPure Corporation (USA)

ZenPure Americas, Inc. (USA)

ZenPure (Hangzhou) Co., Ltd.

Buyer is responsible for complying with all laws and regulations applica-ble to the purchase, export or import of the product of any state or coun-try. Seller’s liability to Buyer under this Agreement shall be limited to the value of the products that are subject to such claim. In no event will Seller be liable to Buyer for lost profits or revenues, claims of Buyer’s customers or any special, indirect, consequential or incidental damages. The failure of Seller to enforce at any time any of the provisions of this contract, to exercise any election or option provided herein, or to require at any time performance by Buyer of any of the provisions herewith shall in no way be construed to be a waiver of any such provisions, or the right of Seller thereafter to enforce each and every provision.

14. Seller: For purposes, herein, the term “Seller” shall mean, as appli-cable, ZenPure (Hangzhou), Co., Ltd., ZenPure Corp. and ZenPure Americas, Inc. For purposes of Sections 8, 9 and 12, the term “Seller” shall apply to, and inure to the benefit of, the applicable Seller, and each other entity listed in this Section 14 and their respective parents, affiliates, successors and assigns. Each such other party shall be a third party beneficiary under this Agreement.

TERMS AND CONDITIONS OF SALE

Page 217

Page 219: ZenPure - Q-Test

ZenPure (Hangzhou) Co., Ltd. 108 10th High-Tech Road, Xiaoshan Qiaonan Industrial Zone Hangzhou, 311231, P. R. China Tel: (86) 571 2288 6800 Fax: (86) 571 2288 6808 Email: [email protected]

ZenPure

ZenPure Corporation Henderson, NV 89016 Tel: (+1) 703-335-9910 Fax: (+1) 703-574-8060 email: [email protected]

ZenPure Americas Inc. P.O. Box 597 Manassas, VA 20108 Tel: (+1) 703-335-9910 Fax: (+1) 703-574-8060 email: [email protected]

ZenPure Corporation (USA)

ZenPure Americas, Inc. (USA)

ZenPure (Hangzhou) Co., Ltd.

ZenPure® is a registered trademark of ZenPure Corporation ZenCap® is a registered trademark of ZenPure Corporation PureFlo® is a registered trademark of ZenPure Corporation JALT Technologies® is a registered trademark of ZenPure Corporation CPC is a Trademark of Colder Products Company LinkTech is a Trademark of LinkTech Corporation Millipore is a Trademark of Millipore Corporation OptiSeal is a Trademark of Millipore Corporation PALL is a Trademark of Pall Corporation SealKleen is a Trademark of Pall Corporation Teflon is a Trademark of DuPont Corporation Viton is a Trademark of DuPont Corporation Walther is a Trademark of Walther Couplings

Trademarks

Page 218

Page 220: ZenPure - Q-Test

ZenPure Z

en

Pu

re

Index by Filter Prefix

Descriptin Filter PrefixCatalog Page

Number

MAXX Glass Fiber Element for Bag Filter Housing BMF*** 170

Resinator Bag Filter BRB*** 182

PureFlo Lenticular Cloud Filter CEP*** 76

PureFlo Filtration Discs CN, DP, E, F, M, N, NS, P, HF, S*** 7

Portable Filter Bag Cart CUSTOM 204

PureFlo D13 Disc Capsule D13R*** 11

PureFlo D13U Disc Capsule D13U*** 12

PureFlo D25C Disc Capsule D25C*** 13

PureFlo D25U Disc Capsule D25U*** 14

PureFlo D4 Disc Capsule D4*** 10

PureFlo D40C Disc Capsule D40C*** 15

PureFlo D50C Disc Capsule D50C*** 16

PureFlo Lenticular Cloud D65R Disc Capsule D65CEP*** 70

PureFlo D65R Disc Capsule D65R*** 19

Silicon Heater for D65 D65-SHS80501 21

Stainless Steel Disc Holder DH*** 184

Stainless Steel Disc Media Holder DMP*** 185

PureFlo EDF Capsule EDF*** 94

PureFlo Charged Nylon Mini Cartridge EMN*** 162

PureFlo Charged Nylon Cartridge EPN*** 122

PureFlo EPS Cartridge EPS*** 132

PureFlo Filter Cups FS*** 8

PureFlo G50C Disc Capsule G50C*** 17

Band Clamp SS Filter Housing Multi-round GTCHB*** 197

Hi-Pro Micro Felt Bag Filter HPM*** 174

Industrial Economy Filter Housing Multi-round IE*** 196

PureFlo Ink Capsule IFC*** 80

Industrial High Purity SS Housing Multi-round IHP*** 195

Industrial Stainless Steel Housing IHP01*** 193

Industrial High Purity Vent Housing IHP1IV*** 205

Industrial High Purity Bag Filter Housing IHPB*** 198

ZenPure Media Options Information 5

ZenPure Capsule Size Options Information 6

ZenPure Vent & Drain Info for SK Capsules Information 28

PureFlo Mini Cartridge Configuration Information Information 147

Benefits of Electropolishing Information 212

Chemical Compatability Table Information 213

Terms & Conditions Information 216

Trademarks Information 218

PureFlo Mini Depth Pleated PP Cartridge JDP*** 152

PureFlo Junior Capsule JKL, JNL, JKP*** 22

Thermally Bonded PP JT*** 140

ZenCap LT and LI Capsule L*** 78

ZenCap Lenticular Cloud Capsule L**CEP*** 75

Thermally Bonded PP LF-PP** 142

PureFlo ZenCap Void Filter Capsule LV*** 89

PureFlo Hi Temp PTFE Filter Cartridge w/Hi=Temp PP Construction MBF*** 112

PureFlo PES Beverage Grade Cartridge MBS*** 130

PureFlo PE Cartridge MCE*** 115

PureFlo Mini Lenticular Cloud Filter MCEP*** 74

PureFlo PTFE Filter Cartridge MCF*** 106

PureFlo Nylon Cartridge MCN*** 116

PureFlo Polypropylene membrane Cartridge MCP*** 98

PureFlo PES Cartridge MCS*** 124

PureFlo PES Biological Reduction Grade Cartridge MCS*** -B 128

PureFlo PES Pharma Grade Cartridge MCS*** -PH 126

PureFlo General Grade Cartridge MGS*** 134

PureFlo Junior Cartridge MJ*** 96

PureFlo MKL Capsule MKL, MKP*** 24

PureFlo MKL Capsule PE MKPE***-E 26

PureFlo PE Mini Cartridge MME*** 158

PureFlo PTFE Mini Filter Cartridge MMF*** 154

PureFlo Nylon Mini Cartridge MMN*** 160

PureFlo Polypro Membrane Mini Cartridge MMP*** 148

PureFlo PES Mini Cartridge MMS*** 164

Page 219

Page 221: ZenPure - Q-Test

ZenPure Z

en

Pu

re

Index by Filter Prefix

Descriptin Filter PrefixCatalog Page

Number

PureFlo Hi Temp PTFE Filter Cartridge Nylon Construction MNF*** 108

PureFlo Nylon Plus Cartridge MNN*** 118

PureFlo Charged Nylon Cartridge MPN*** 122

PureFlo PES Pharma Grade Cartridge Dual Layer MPS***-PH 126

PureFlo Hi Temp PTFE Filter Cartridge w/SS Core MSF*** 110

PureFlo All-Nylon Cartridge MSN*** 120

PureFlo PE Mini Vent Cartridge MVE*** 156

PureFlo PTFE Mini Vent Cartridge MVF*** 156

PureFlo Water Grade Cartridge MWS*** 136

PureFlo Glass MicroFiber Cartridge NCG*** 138

PureFlo Polypropylene Media Cartridge NCP*** 100

PureFlo Depth Pleated PP cartrdige NDP*** 102

PureFlo Industrial PP Cartridge NIP*** 104

PureFlo Glass MicroFiber Mini Cartirdge NMG*** 166

Nylon mono-filiment Mesh Bag Filter NMO*** 178

PureFlo Polypro Media Mini Cartridge NMP*** 150

Nylon Multi-filiment Mesh Bag Filter NMU*** 178

Sample & Vent Valves OFSB*** 208

Polyester Felt Bag Filter PE*** 176

Polyester Chem Bag PE***-CB 180

MAXX Polyester Felt Element for Bag Filter Housing PEF*** 171

Polyester mono-filiment Mesh Bag Filter PEMO*** 178

Polyester Multi-filiment Mesh Bag Filter PEMU*** 178

Virgin Polypropylene Housing PHV010*** 186

MAXX PP Microfiber Element for Bag Filter Housing PMF*** 169

Polypropylene mono-filiment Mesh Bag Filter POMO*** 178

Polypropylene Felt Bag Filter PP*** 176

Polypropylene Chem Bag PP***-CB 180

MAXX PP Felt Element for BaG Filter Housing PPF*** 171

MAXX Phenolic Polyester Element for Bag Filter Housing PTP*** 172

Sanitary SS Filter Housing Multi-round SAN*** 192

Sanitary Stainless Steel Housing SHP01*** 190

PureFlo Carbon Fiber/HEPA Capsule SKC***, SKCH***, MKC*** 68

PureFlo Tank Vent Purifier SKCL 82

PureFlo SKL Series Mini Depth pleated PP Media Capsule SKDP*** 64

PureFlo HEPA Capsule SKH*** 66

PureFlo SKL Series Lenticular Cloud Capsule SKLCEP*** 73

PureFlo SKL Series PE Capsule SKLE*** 56

PureFlo SKL Series PTFE Capsule SKLF** 44

PureFlo SKL Series Glass MicroFiber Capsule SKLG*** 58

PureFlo SKL Series PP Membrane Capsule SKLM*** 61

PureFlo SKL Series Nylon Capsule SKLN** 46

PureFlo SKL Series Nylon Screen Capsule SKLNS*** 54

PureFlo SKL Series PP Media Capsule SKLP*** 62

PureFlo SKL Series PES Capsule, Standard Grade SKLS*** 40

PureFlo SKL Series PES Capsule, Biological Reduction Grade SKLS***-B 38

PureFlo SKL Series PES Capsule, Pharma Grade SKLS***-PH 36

PureFlo SKML Mulit-Zone Capsule SKML*** 90

PureFlo SKMV Mulit-Zone Capsule SKMV*** 92

PureFlo SKV Series Lenticular Cloud Capsule SKVCEP*** 72

PureFlo SKV Series PTFE Capsule SKVF** 42

PureFlo SKV Series Nylon Capsule SKVN*** 48

PureFlo Shower Filter SKVPS*** 84

PureFlo SKV Series PES Capsule, Pharma Grade SKVS*** 32

PureFlo SKV Series PES Capsule, Pharma Grade, with PE Construction SKVS***-E 34

Sanitary Mini Stainless Steel Housing SMP01*** 188

PureFlo SNL Series All Nylon Capsule SNLN** 50

PureFlo SNV Series All Nylon Capsule SNVN** 52

SRH Series Bag Housing SRH*** 202

SRL Series Bag Housing SRL*** 200

SRM Series Multi-cavity Housing SRM*** 203

SRS Series Bag Housing SRS*** 201

PureFlo SVL Void Capsule SVL*** 88

Sanitary Stainless Steel Vent Housing SVP017*** 206

PureFlo SVV Void Capsule SVV*** 87

String Wound Filter Cartridge SW*** 144

Sanitary Y-Strainer SYS*** 210

PureFlo Activated Carbon Fiber WCC*** 143

Page 220

Page 222: ZenPure - Q-Test

ZenPure

About ZenPure

ZenPure Corporation was founded in November 2002, specializing in development and manufacturing of filtration and purification products and specialty membrane devices for a wide range of industries and applications. ZenPure strives for customer satisfaction and trust by providing reliable, unique, efficient, and cost effective design, development, and manufacturing services to our customers, including OEM and private labeled products. ZenPure Can offer filters or membrane devices of any size, fitting type, and configuration based on all types of filtration media combinations. All Products are manufactured in a Class 10,000 clean room environment with full material traceability and quality control.