YTMX580 Multi-Input Temperature Transmitter · Cold Junction Compensation Accuracy For T/C only ±...
Transcript of YTMX580 Multi-Input Temperature Transmitter · Cold Junction Compensation Accuracy For T/C only ±...
GeneralSpecifications
<<Contents>> <<Index>>
YTMX580Multi-Input Temperature Transmitter
Yokogawa Electric Corporation2-9-32, Nakacho, Musashino-shi, Tokyo, 180-8750 Japan
GS 04R01B01-01EN
GS 04R01B01-01EN©Copyright September 2011
9th Edition Feb. 28, 2017
The model YTMX580 Multi-Input Temperature Transmitter can accept inputs from up to 8 points of measurement such as thermocouples (8 types: K, E, J, etc.) or RTD signals (3 types: Pt100, etc.), converting the corresponding measurement input values to a wireless signal. It can also accept DC voltage, resistance, and 4–20 mADC signal input. In addition to temperature signals, it can also wirelessly send and receive setting parameters. Internal battery power means eliminating not only signal wires, but also power cables—this offers great installation cost reductions. Also, 24 VDC External power supply (Power supply suffix code: -B) can be specified. The communication is compliant with ISA100.11a* protocol specifications.* ISA100.11a is an industrial automation wireless communication
standard developed by the International Society of Automation (ISA) and is an international standard (IEC 62734) approved by the International Electrotechnical Commission (IEC).
Battery Pack (Battery model)Battery pack with long life lithium-thionyl chloride batteries. With the intrinsically safe type, the battery pack is replaceable in a hazardous area. Typical battery life is 6 years at 60 seconds publication period (update time) in the following conditions.*• Networkconnection:JOINstatus• Ambienttemperature:23±2°C• Devicerole:IOfunctiononly• LEDindicator:off
* Environmental condition such as ambient temperature and vibration may affect the battery life.
■ FUNCTIONALSPECIFICATIONSInputchannels:8pointsInputtypeisselectable:Thermocouples,2-,3-,and4-wireRTDs,ohms,DCmilivoltsandDCmiliamperes(4 to 20 mA, with external shunt resistors). See Table 1.Note: ExplosionproofingnotapplicableduringDCvoltsand
DCmiliamperesinput.MaximumAllowableInputvoltage±2.5VDCCategoryO(Transientovervoltage330V)
InputResistance10MΩormore
InputSignalSourceResistance(forT/C,mV)1kΩorlower
InputLeadWireResistance(forRTD,Ohm)10Ωperwireorlower
OutputISA100 Wireless (IEC802.15.4) 2.4 GHz signal.
FEATURES● LongLifeBatteryDesign
Ultra low current consumption design using two high capacity lithium-thionyl chloride batteries provide wireless operation for years.
● HighSecurityWirelessNetworkConfigurationInfrared communication between the devices for wirelessnetworkconfigurationandparametersetting.
● QuickUpdateTimeSelectable from 1 second to 60 minutes for measured process value to publish wirelessly.
STANDARDSPECIFICATIONS■ WIRELESSSPECIFICATIONSCommunicationprotocol:ISA100Wireless(IEEE802.15.4)Datarate:250kbpsFrequency:2400-2483.5MHzlicensefreeISMbandRadiosecurity:AES128bitcodifiedRFTransmitterpower:Max.11.6dBm(fixed)Antenna:+2dBiOmnidirectionaltype
■ PERFORMANCESPECIFICATIONSAccuracy
See Table 1.ColdJunctionCompensationAccuracy
For T/C only±0.5°C(±0.9°F)(addedtoaccuracywhenusingthermocouple input)
AmbientTemperatureEffect(per1.0°Cchange)See Table 2.
2
All Rights Reserved. Copyright © 2011, Yokogawa Electric Corporation
<<Contents>> <<Index>>
GS 04R01B01-01EN Feb. 28, 2017-00
MeasurementRangeSee Table 1.
PublicationPeriod(UpdateTime)1 to 3600 sec selectable.Minimum of 2 seconds with 4 or more measuring points.
Zero-gainAdjustmentSet the amount of zero-gain point adjustment.
StatusDisplayTheRDY(green)andALM(red)LEDsindicatethefollowingstatuses:Starting,Running,Waitingto"JOIN"(network),Squawk,Alarm,DeepSleep
SensorBurnoutSelectHIGH,LOWorOFFastheconfiguration.(usesetting software)
SelfDiagnosticsAmplifierfailure,sensorfailure,configurationerror,battery alarm, wireless communication alarm and over-range error for process variables.
SoftwareDownloadFunctionSoftware download function permits to update wirelessfielddevicesoftwareviaISA100wirelesscommunication.
DeviceRoleThe following 2 device roles are supported depending on the network topology.• IOFunctiononly(IO)• IOFunctionandRoutingFunction(IO+Router)
Star
GW : GatewayIO : YTMX580 IO + R : YTMX580
IO
GW
IOIO
GW : Gateway
IO IO+Router
E01.ai
IO : YTMX580
GW
IO+R IO+RIO
IO IO
Network form Mesh
Device Role
Example network
connections and
devices
InfraredCommunicationDatarate:9600bpsDistance:Infraredsurfaceofthenearinfraredadapter should be within 30 cm
PowerSupply•BatteryModel2xprimarylithium-thionylchloridebatteries(sizeD)With battery case (batteries sold separately)
•ExternalPowerSupplyModelRatedsupplyvoltage:24VDCAllowablepowersupplyvoltagerange: 10.5to26.4VDCPowerconsumption:Max1.2W
InsulationResistanceMeasuringinputterminaltogroundterminal: 100MΩorgreater(at500VDC)
DielectricStrengthDielectricstrengththatcanwithstandthefollowingconditions
•BatteryModelMeasuringinputterminaltogroundterminal: 500VAC(50/60Hz),1min,leakagecurrentof
5 mA or lessBetweenmeasuringinputterminal: 200VAC(50/60Hz),1min,leakagecurrentof
5 mA or less•ExternalPowerSupplyModelPowerterminaltogroundterminal: 500VAC(50/60Hz),1min,leakagecurrent
of 5 mA or lessNote:Thepowersupplyterminalhasabuilt-insurge
protection device. The terminal without the surge protection device has the dielectric strength shown above.
Measuringinputterminaltogroundterminal: 500VAC(50/60Hz),1min,leakagecurrent
of 5 mA or lessBetweenmeasuringinputterminal: 200VAC(50/60Hz),1min,leakagecurrent
of 5 mA or less
■ NORMALOPERATINGCONDITION(Optionalfeaturesorapprovalcodesmayaffectlimits.)
AmbientTemperatureLimits-40to85°C(-40to185°F)As for explosion protect type, seeREGULATORYCOMPLIANCESTATEMENTS
AmbientHumidityLimits0 to 100 % RH
StorageTemperature-40to85°C(-40to185°F)
Vibration3G or less, at resonant frequencies from 10 to 2000 Hz (IEC 60770-1)
3<<Contents>> <<Index>>
All Rights Reserved. Copyright © 2011, Yokogawa Electric Corporation GS 04R01B01-01EN Feb. 28, 2017-00
■ REGULATORYCOMPLIANCESTATEMENTSThis device contains the wireless module. The wirelessmodulesatisfiesthefollowingstandards.* Pleaseconfirmthatainstallationregionfulfills
a standards, require additional regulatory information and approvals, contact to Yokogawa Electric Corporation.
SafetyStandardsEN 61010-1, EN 61010-2-030CSA C22.2 No.61010-1-12CSA C22.2 No.61010-2-030-12UL61010-1,UL61010-2-030(CSANRTL/C)OvervoltageCategoryI,PollutionDegree2Indoor/Outdooruse
EMCConformityStandardsEN 61326-1 Class A Table 2 (For use in industrial locations), EN 61326-2-3
* Duringthetest,thetransmittercontinuestooperate under the electromagnetic effects of within±1%ofthespan.
EN 301 489-1, EN 301 489-17
R&TTEConformityStandardsETSI EN 300 328, ETSI EN 301 489-1,ETSI EN 301 489-17, EN 62311
The CE declaration of conformity for R&TTE for this product can be found at
<http://www.field-wireless.com/>RegulationConformityoftheWirelessModule
• FCCApproval• ICApproval• JapaneseRadioLaw(ConstructionDesign
AttestationNumber:007WWCUL0480)KoreaCertification(RadioWaveAct)
KCC-REM-YHQ-WEN007EMCandRadiocommunicationsregulatoryarrangementinAustraliaandNewZealand(RCM)AS/NZS 4268AS/NZS 2772.2EN 61326-1 Class A, Table2 (For use in industrial location)
ExplosionProtectionFM Intrinsically safe, nonincendive ApprovalIntrinsicallySafeforClassI,Division1,GroupsA,B,C&D,ClassII,Division1,GroupsE,F&GandClassIII,Division1,ClassI,Zone0,inHazardousLocations,AExiaIICNonincendiveforClassI,Division2,GroupsA,B,C&D,ClassII,Division2,GroupsF&GandClassIII,Division1,ClassI,Zone2,GroupIIC,inHazardousLocationsInputParameter:Ui=28V,Ii=135mA,
Pi=850mW,Ci=0.013μF,Li=0.24mHSensorCircuitParameter:Voc,Uo=5.88V,
Isc,Io=130.1mA,Po=191.2mW,Ca,Co=1μF,La,Lo=1mH
Ambienttemperature:–50to70°C(-58to158°F)Enclosure:NEMAType4X
CSA Intrinsically safe Approval, non-incendive ApprovalCertificateNo.:2495456IntrinsicallySafeforClassI,Division1,GroupsA,B,C&D,ClassII,Division1,GroupsE,F&G,ClassIII,Division1Non-incendiveforClassI,Division2,GroupsA,B,C&D,ClassII,Division2,GroupsF&G,ClassIII,Division1Enclosure:Type4X,IP66/IP67TemperatureCode:T4Ex ia IIC T4InputParameter:Ui=28V,Ii=135mA,
Pi=850mW,Ci=0.013μF,Li=0.24mHSensorCircuitParameter:Uo=5.88V,
Io=130.1mA,Po=191.2mW,Co=1μF, Lo=1mHAmbienttemperature:–50to70°C
ATEX Intrinsically safe ApprovalCertificateNo.:DEKRA12ATEX0068XII 1 G Ex ia IIC T4 GaInputParameter:Ui=28V,Ii=135mA,
Pi=850mW,Ci=0.013μF,Li=0.24mHSensorCircuitParameter:Uo=5.88V,
Io=130.1mA,Po=191.2mW,Co=1μF, Lo=1mHAmbienttemperature:–50to70°CEnclosure:IP66/IP67
IECEx Intrinsically safe ApprovalCertificateNo.:IECExDEK12.0013XEx ia IIC T4 GaInputParameter:Ui=28V,Ii=135mA,
Pi=850mW,Ci=0.013μF,Li=0.24mHSensorCircuitParameter:Uo=5.88V,
Io=130.1mA,Po=191.2mW,Co=1μF, Lo=1mHAmbienttemperature:–50to70°CEnclosure:IP66/IP67
4
All Rights Reserved. Copyright © 2011, Yokogawa Electric Corporation
<<Contents>> <<Index>>
GS 04R01B01-01EN Feb. 28, 2017-00
TIIS intrinsically safe ApprovalBattery Model (Integral antenna)Approvalnumber:TC20543Ex ia IIC T4 XPowerSupply:Batterypack(F9915MA)orbatterycase(F9915NS)DC7.2VSensorCircuitParameter:Uo=5.88V, Io=130.1mA,Po=191.3mW, Co=1μF,Lo=1mHAmbienttemperature:–20to60°CEnclosure:IP66/IP67
Battery model (Remote antenna)Approvalnumber:TC20816Ex ia IIC T4 XPowerSupply:Batterypack(F9915MA)orbatterycase(F9915NS)DC7.2VSensorCircuitParameter:Uo=5.88V, Io=130.1mA,Po=191.3mW, Co=1μF,Lo=1mHAntennaCircuit:Uo=5.88V,Io=177.4mA, Po=349.5mWAmbientTemperature:–20to60°CEnclosure:IP20
ExternalPowerSupplyModel(Integralantenna)Approvalnumber:TC21262Ex ia IIC T4 XInputParameter:Ui=28V,Ii=135mA, Pi=850mW,Ci=0.013μF, Li=0.24mHSensorCircuitParameter:Uo=5.88V, Io=130.1mA,Po=191.3mW, Co=1μF,Lo=1mHAmbientTemperature:–50to70°CEnclosure:IP20
ExternalPowerSupplyModel(Remoteantenna)Approvalnumber:TC21344Ex ia IIC T4 XInputParameter:Ui=28V,Ii=135mA, Pi=850mW,Ci=0.013μF, Li=0.24mHSensorCircuitParameter:Uo=5.88V, Io=130.1mA,Po=191.3mW, Co=1μF,Lo=1mHAntennaCircuit:Uo=5.88V,Io=177.4mA, Po=349.5mWAmbientTemperature:–50to70°CEnclosure:IP20
EnclosureIntheexamination,IP20enclosure,whichisthe lowest intrinsically safe explosion-proof requirement,hasbeenverified,butboththeintegrated antenna model and remote antenna model can be used in an environment that requires IP66/IP67.
■ PHYSICALSPECIFICATIONSEnclosureHousingLowcoppercastaluminumalloy
Coating• Standardcoating polyurethane, mint-green paint. (Munsell 5.6 BG
3.3/2.9 or its equivalent)• Highanti-corrosioncoating(OptionCode/X2) Basecoating:epoxyresincoating Finishcoating:polyurethanecoating The color is same as standard type.
DegreesofProtectionIP66/IP67,NEMAType4XNote:ForIntrinsicallysafeApproval,refertoREGULATORYCOMPLIANCESTATEMENTS
ConnectionsReferto“MODELANDSUFFIXCODES.”
ConnectionTerminal4 mm Screw terminal
NamePlateandTag316 SST
MountingBlacket316 SSTSelect pipe mounting or wall mounting
Weight3.2 kg (7.05 lb)Without mounting bracket.
■ ACCESSORIESRemoteAntennaCable(optionalaccessories)(Onlybyorderofoption)
SpecificationofCable:8D-SFA(HDPE)OutsideDiameterofCable:11.1mmMinimumBendRadius:67mm(whenfixing) 167 mm (when wiring)CableEndTreatment:Ntypeconnector,oneendismale and the other is female.Operationaltemperaturerange:-40to+85°C (-40to185°F)
*“Whenfixing”showsthebendingradiusforfixing(thestate is maintained for a long time).
“Whenwiring”showsthebendingradiuswhilechecking the wiring position. This bending radius issetlargerthanthatforfixinginordertopreventdamage to the cable because the cable is likely to berepeatedlybentwhencheckingthefinalwiringposition.
5<<Contents>> <<Index>>
All Rights Reserved. Copyright © 2011, Yokogawa Electric Corporation GS 04R01B01-01EN Feb. 28, 2017-00
Table1.Sensortype,measurementrange,andaccuracySensorType Standard MeasurementRange Accuracy
T/C
B
IEC 60584
100to1820°C(212.0to3308.0°F) Accuracy not guaranteed for less than 400°C(752.0°F)±2.54°C(±4.57°F)intherangefrom400°C(752.0°F)ormoretolessthan800°C(1472.0°F)±1.54°C(±2.78°F)for800°C(1472.0°F)ormore
E -200to1000°C(-328.0to1832.0°F) ±0.80°C(±1.44°F)forlessthan0°C(32.0°F)±0.40°C(±0.72°F)for0°C(32.0°F)or more
J -180to760°C(-292.0to1400.0°F) ±0.80°C(±1.44°F)forlessthan0°C(32.0°F)±0.70°C(±1.26°F)for0°C(32.0°F)or more
K -180to1372°C(-292.0to2501.6°F) ±1.10°C(±1.98°F)forlessthan0°C(32.0°F)±1.0°C(±1.80°F)for0°C(32.0°F)or more
N -200to1300°C(-328.0to2372.0°F) ±2.0°C(±3.60°F)forlessthan0°C(32.0°F)±1.0°C(±1.80°F)for0°C(32.0°F)or more
R
0to1768°C(32.0to3214.4°F) ±2.00°C(±3.60°F)forlessthan200°C(392.0°F)±1.50°C(±2.70°F)for200°C(392.0°F)ormore
S
0to1768°C(32.0to3214.4°F) ±2.00°C(±3.60°F)forlessthan200°C(392.0°F)±1.40°C(±2.52°F)for200°C(392.0°F)ormore
T -200to400°C(-328.0to752.0°F) ±0.70°C(±1.26°F)
RTD
Pt100
IEC 60751
-200to850°C(-328.0to1562.0°F) ±0.30°C(±0.54°F)forlessthan400°C(752.0°F)±0.40°C(±0.72°F)intherangefrom400°C(752.0°F)ormoretolessthan500°C(932.0°F)±0.50°C(±0.90°F)for500°C(932.0°F)ormore
Pt200
-200to850°C(-328.0to1562.0°F) ±0.54°C(±0.98°F)forlessthan400°C(752.0°F)±0.64°C(±1.15°F)intherangefrom400°C(752.0°F)ormoretolessthan500°C(932.0°F)±0.74°C(±1.33°F)for500°C(932.0°F)ormore
Pt500
-200to850°C(-328.0to1562.0°F) ±0.38°C(±0.68°F)forlessthan400°C(752.0°F)±0.48°C(±0.86°F)intherangefrom400°C(752.0°F)ormoretolessthan500°C(932.0°F)±0.58°C(±1.04°F)for500°C(932.0°F)ormore
mV - -10to100[mV] ±0.035[mV]V - -0.01to1[V] ±0.001[V]
Ohm - 0to2000[Ω] ±1.0[Ω]
Note1: ForT/Cinput,addColdJunctionCompensationAccuracy(±0.5°C)tothetotalaccuracy.Note2: ForRTDinputofthe2-wireconnection,addacorrectedvalue(±0.1°C)tothetotalaccuracy.Note3: ForDCmiliamperes(4to20mA),connectexternalshuntresistors.Note4: Explosionproofingnotapplicableto[DCvolts,DCmiliamperes].
6
All Rights Reserved. Copyright © 2011, Yokogawa Electric Corporation
<<Contents>> <<Index>>
GS 04R01B01-01EN Feb. 28, 2017-00
Table2.Effectsofambienttemperature
SensorType TemperatureEffectsper1.0°CChangeinAmbientTemperature MeasurementRange
T/C
B
0.2°C-(0.066%of(t-100)) t<300°C
0.07°C-(0.0057%of(t-300)) 300°C≤t<1000°C
0.037°C t≥1000°C
E0.035°C-(0.00492%oft) t<0°C
0.035°C-(0.00146%oft) t≥0°C
J0.0039°C-(0.00529%oft) t<0°C
0.0039°C+(0.00149%oft) t≥0°C
K0.00521°C-(0.00707%oft) t<0°C
0.00521°C+(0.00182%oft) t≥0°C
N0.0077°C-(0.00918%oft) t<0°C
0.0077°C+(0.00136%oft) t≥0°C
R, S
0.04°C0+(0.0102%oft) t<100°C
0.0316°C-(0.001%oft) 100°C≤t<600°C
0.0175°C+(0.00173%oft) t≥600°C
T0.00513°C-(0.00631%oft) t<0°C
0.00513°C+(0.0008%oft) t≥0°C
RTD
Pt100 0.0048°C+(0.0016%ofabsolutevaluet) Entire Sensor Input Range
Pt2000.0038°C+(0.0015%ofabsolutevaluet) t<650°C
0.0028°C+(0.0016%oft) t≥650°C
Pt5000.003°C+(0.0014%ofabsolutevaluet) t<650°C
0.002°C+(0.0016%oft) t≥650°C
mV 0.0002mV+(0.0015%ofreading) Entire Sensor Input Range
V 0.005mV+(0.0015%ofreading) Entire Sensor Input Range
Ohm 0.001Ω+(0.0009%ofreading) Entire Sensor Input Range
Note1: The“t”onTable2meansthevalueofthereadingin°C.Note2: The“absolutevaluet”onTable2meanstheabsolutevalueofthereadingin°C. [Exampleofabsolutevaluet] When the temperature value is 250 Kelvin, abs reading is 23.15, absolute (250 - 273.15).
7<<Contents>> <<Index>>
All Rights Reserved. Copyright © 2011, Yokogawa Electric Corporation GS 04R01B01-01EN Feb. 28, 2017-00
MODELANDSUFFIXCODESModel SuffixCode Descriptions
YTMX580 Multi-Input Temperature TransmitterOutputSignal -L Wireless communication (ISA100 Wireless)Housing 7 Always 7
Electrical Connection0 G 1/2 female, nine electrical connections2 1/2NPTfemale,nineelectricalconnections4 M20 female, nine electrical connections
Integral Indicator N None
Mounting BracketL 316 SST 2-inch pipe mountingW 316 SST wall mounting*1
N NonePowerSupply -A Battery (case only, battery not included), with a blind plug
-B 24VDC,withoutablindplugAntenna*5 A Integral antenna
B Remote antenna*4
Temperature Unit -A Cel, K *2
-B Cel, K, degF, degR *3
--- A Always AOptionCodes Optionalspecifications(SeeOptionCode)
*1: Forwallmounting,pleaseprepareboltsandnuts.*2: ThisisaJapan-onlyspecification(onlyavailabletoendusersinsideJapan).*3: InJapan,degF(°F)anddegR(°R)arenon-statutorymeasurementunits.Suffixcode-Bcanonlybespecifiedbyendusers
outside of Japan.*4: Ordertheremoteantennacablesseparatelyfromaccessaryoption.*5: Useofantennaislimitedbylocalregulationofradioandtelecommunicationlaw.ConsultYokogawafordetails.Note:"Cel"means"°C","degF"means"°F"and"degR"means"°R".
OPTIONALSPECIFICATIONItem Description OptionCode
Coating High anti-corrosion coating /X2Factoryconfiguredsettings Factoryconfiguredsettingswithmultipleinputtypes/ranges /FC1*1
*1: Iftheoptioncoderelatedtoexplosionprotectionisspecified,EitherDCV(mV)orDCV(V)assensortypeisshouldNOTbeapplied.
OPTIONALSPECIFICATION(ForExplosionProtectedtype)Item Description OptionCode
Canadian Standards Association (CSA) CSA Intrinsically safe and non-incendive approval /CS17*1
Factory Mutual (FM) FM intrinsically safe and nonincendive approval /FS17*1
TIIS TIIS intrinsically safe approval /JS37*1
ATEX ATEX intrinsically safe approval /KS27*1
IECEx Scheme IECEx intrinsically safe approval /SS27*1
*1: /CS17,/FS17,/JS37,/KS27,/SS27cannotbespecifiedtogether.
StandaradAccessoriesProduct Qty
User's manual (Booklet) 1Mounting bracket*1 (2-inch pipe mounting or wall mounting) 1 setBattery case ( installed in the main body. )*3 1Remote antenna*2 1
*1: Notincludedifspecifyingnomountingbrackets(MountingbracketsuffixcodeisN).*2: Withtheremoteantennaoption(AntennatypesuffixcodeisB).*3: Whenbatteryisspecifiedforthepowersupply(Powersupplysuffixcodeis-A)
8
All Rights Reserved. Copyright © 2011, Yokogawa Electric Corporation
<<Contents>> <<Index>>
GS 04R01B01-01EN Feb. 28, 2017-00
OptionalAccessoriesProduct Modelcode(partnumber) Specification
Remote antenna cable*1 F9193UA Antennacable:1m,Operationaltemperaturerange:-40to+85°C,Withremoteantennamountingbracket.
F9193UB Antennacable:3m,Operationaltemperaturerange:-40to+85°C,Withremoteantennamountingbracket.
F9193UC Antennacable:4m(1m+3m)witharrestor,Operationaltemperaturerange:-40to+85°C,Withremoteantennamountingbracket.
F9193UD Antennacable:6m(3m+3m)witharrestor,Operationaltemperaturerange:-40to+85°C,Withremoteantennamountingbracket.
F9193UE Antennacable:13m(3m+10m)witharrestor,Operationaltemperaturerange:-40to+85°C,Withremoteantennamountingbracket.
Antenna*1 F9193DH +2dBiRemoteAntenna(White)
*1: Useofremoteantennacableislimitedbylocalregulationofradioandtelecommunicationlaw.ConsultYokogawafordetails.
Product Modelcode(partnumber) SpecificationBattery pack assembly F9915NQ*1 Batterycase,Lithium-thionylchloridebatteries2piecesBattery case F9915NK*2 Battery case onlyBatteries F9915NR Lithium-thionylchloridebatteries,2pieces
Front door part
B8808DE Front door Gasket, 1 pieceB8808DM FrontdoorBoltCap(Long),1pieceB8808DN Front door Bolt Cap (Short) , 1 pieceB8808EM Front door Bolt SUS316, 1 piece
BracketB8808DW 2BPipeMountingBracketSUS316B8808DV Wall Mounting Bracket SUS316
Shunt resistor X010-050-1 50Ω±0.1%,for4mmscrewterminals,Operationaltemperaturerange:-25to+80°C
*1: IfyouneedF9915MA,pleasepurchaseF9915NQ.F9915NQisasetofF9915MAandinstructionmanual.*2: IfyouneedF9915NS,pleasepurchaseF9915NK.F9915NKisasetofF9915NSandinstructionmanual.
Model SurffixCode DescriptionYTMXBP Blind plug for electrical connection
Type and Quantity
-A1 G 1/2, 1 piece-A4 G 1/2, 4 pieces-A7 G 1/2, 7 pieces-C1 1/2NPT,1piece-C4 1/2NPT,4pieces-C7 1/2NPT,7pieces-D1 M20, 1 piece-D4 M20, 4 pieces-D7 M20, 7 pieces
9<<Contents>> <<Index>>
All Rights Reserved. Copyright © 2011, Yokogawa Electric Corporation GS 04R01B01-01EN Feb. 28, 2017-00
Note:Ifnotspecified,thetoleranceis3%.However,fordimentionslessthan10mm,thetoleranceis0.3mm.
DIMENSIONS● 2-inchpipemounting(verticalorhorizontalpipe)
E02.ai
246
(9.6
9)89
.5 (3
.52)
□ Height of directly attach the remote antenna to the body
173
(6.8
1)
89.5
(3.5
2)16
4 (6
.46)
133.8 (5.27)
118 (4.65)118 (4.65)
120 (4.72)
125 (4.92)
147.3 (5.80)
67.3 45.2
110
(4.3
3)
Mounting bracket
(2.65)
2-inch pipe(O.D. 60 mm)
Unit: mm (approx. inch)
(1.78)
48 48 48 48
3055
.8
48 48 48
(1.1
8)(2
.20)
Electrical connection
(1.89)
(1.89)
10
All Rights Reserved. Copyright © 2011, Yokogawa Electric Corporation
<<Contents>> <<Index>>
GS 04R01B01-01EN Feb. 28, 2017-00
● Wallmounting
E03.ai
256 (10)276 (10.87)
184
(7.2
4)
143 (5.63)
335.
5 (1
3.21
)33
8 (1
3.31
)
256
(10.
08)
164
(6.4
6)
10
10
Mounting bracket
Unit: mm (approx. inch)
(0.39)
□ Height of directly attach the remote antenna to the body
48 48 48 48
48 48 48
3051
.3
(1.89)
(1.89)
Electrical connection
(2.0
2)(1
.18)
4-Ø6.2
□ Wall mounting dimensions4-Φ6.2±0.2 holeor M5 tapping
164±0
.5(6
.46±0
.02 )
256±0.5(10.08±0.02)
Note:Ifnotspecified,thetoleranceis3%.However,fordimentionslessthan10mm,thetoleranceis0.3mm.
11<<Contents>> <<Index>>
All Rights Reserved. Copyright © 2011, Yokogawa Electric Corporation GS 04R01B01-01EN Feb. 28, 2017-00
● RemoteantenabracketUnit: mm (approx. inch)
2-inch pipe
71.7 (2.82)17 (0.67) 37.3 (1.47)
J04.ai
17.5 (0.69)
87.7
(3.4
5)
98 (3.86)
135
(5.3
1)29
2 (1
1.50
)
minimum R67
● Remoteantenna
Main unit Main unit
Antenna
Antenna
CableLength : 1 m or 3 m (selectable)
Cable 2Length : 3 m or 10 m (selectable)
Cable 1Length : 1 m or 3 m (selectable)
E05.ai
<With arrester><Without arrester>
Arrester
150
18
Ø20.5
□ AntennaAntenna* Non-direction antenna* Gain : +2 dBi*Part number: F9193DH
□ Antenna cableHigh-frequency coaxial cable* Sheath dia : 11.11mm
Note:Ifnotspecified,thetoleranceis3%.However,fordimentionslessthan10mm,thetoleranceis0.3mm.
12
All Rights Reserved. Copyright © 2011, Yokogawa Electric Corporation
<<Contents>> <<Index>>
GS 04R01B01-01EN Feb. 28, 2017-00
● ExternalPowerSupplyWiring
External Power Supply (24V DC)
E09.ai
● TerminalConfiguration
E07.ai
Ground terminal
Ground terminal● InputWiring
TC or DC millivolts
(+)(–)
two-wireRTD or ohm
three-wireRTD or ohm
four-wireRTD or ohm
(B)(A) (b)
(B)
(A)(A)
(b)(B)
(a)
4~20mAdevice
Powersupply50Ω
(+)(+)
(–)(–)
DC milliamperes( use a shunt resistor )
E08.ai
● InfraredConfiguration
E06.ai
Infrared port
13
All Rights Reserved. Copyright © 2011, Yokogawa Electric Corporation
<<Contents>> <<Index>>
GS 04R01B01-01EN
13<<Contents>> <<Index>>
Feb. 28, 2017-00Subject to change without notice.
<OrderingInformation>SpecifythefollowingwhenorderingModel,suffixcodes, and optional codes. The instrument is shipped with the settings shown in Table A.1. Sensor type.
1) Select an input sensor type from table 1. Each input is of the same type.
2)ForRTDandresistanceinput,specifythenumberofwireaswell.(Example;Pt1003-wiresystem)
3)Withthe/FC1option(Factoryconfiguredsettingswith multiple input types/ ranges), please indicate the type of sensor for each input. You can also select"NOT_USED"forinputs2through8.
Note1:Iftheoptioncoderelatedtoexplosionprotectionisspecified,EitherDCV(mV)orDCV(V)assensortypeisshouldNOTbeapplied.
Note2:Iftheperiodofmeasurementis1second,themaximum number of measuring points is 3. At a 1-second period, the sensor type for at least 5 pointsmustbesetto“NOT_USED.”
2. Calibration range and unit (if required)1)Calibrationrangecanbespecifiedwithinthe
measurement range shown in Table 1. With the /FC1 option, please indicate the upper
and lower limit values for each input. If /FC1 is notspecified,theupperandlowerlimitvaluesforall inputs will be the same.
2)Pleasespecifytheunitsoftemperatureforeachinput(°C,°K,°F,or°R).°Fand°RareavailablewhenTemperatureUnitsuffixcode-Bisspecified.(InJapan,°Fand°Rarenon-statutorymeasurementunits.Suffixcode-BcanonlybespecifiedbyendusersoutsideofJapan.)
With the /FC1 option, please indicate the unit for eachinput.If/FC1isnotspecified,theunitforallinputs will be the same.
ItisnotnecessarytospecifytheunitofmV,Vand ohm inputs, for these units automatically will bemV,VorOhm.
3. Tag Number (if required) Specify Tag number (up to 16 letters) to be
engravedonthetagplate.Also,thespecifiedlettersarewrittentothe“Tag_Name“(16letters)oftheamplifiermemory.Thecharacterscanbespecifiedusingalphanumericandthesymbols,[-]and[.].DonotwriteanythingtoTagnumberwhen nothing is engraved on the tag plate.
4. Software tag (if required) Specify this software tag when the tag number
required is different from the tag number specifiedfortheTagplate.Thetagnumberspecifiedin“Softwaretag”willbeenteredon“Tag_Name”(upto16letters)intheamplifiermemory.
5.NetworkID(ifrequired) Specify the number from 2 to 65535.When not
specified,itwillbe1.Note Lower-casealphabetcharactersandperiods
[.]cannotbeusedinYokogawa’sconfigurationsoftware.Specifythetagname(Tag_Name)usinga combination of upper-case alphabet characters, numbers,andhyphens[-].
<FactorySetting>TableA.SettingsuponshipmentTag No. “Blank”orasspecifiedinorder
Calibration range and unit See Table 1. Measurement Range orasspecifiedinorder
<RelatedInstruments>PaperlessRecorderWirelessModelGX20WRefertoGS04L51B11-01EN,GS04L53B01-01EN(I/OModules)
FieldWirelessIntegratedGatewayYFGW710:Refer to GS 01W01F01-01EN
FieldWirelessManagementStationYFGW410:RefertoGS01W02D01-01EN
FieldWirelessAccessPointYFGW510:Refer to GS 01W02E01-01EN
FieldWirelessMediaConverterYFGW610:RefertoGS01W02D02-01EN
VersatileDeviceManagementWizardFieldMate:Refer to GS 01R01A01-01E
Thermocouple:RefertoGS06B01B01-00E,GS 06B01E01-00E
MineralInsulatedThermocouple:RefertoGS06B02D01-00E
ResistanceTemperatureSensor:RefertoGS06B03B01-00E,GS06B04D01-00E
ProtectionTube,Thermowell:Refer to GS 06B02T02-00E
PaperlessRecorderModelGX10/GX20/GP10/GP20RefertoGS04L51B01-01EN(GX10/GX20),GS04L52B01-01EN(GP10/GP20),GS04L53B01-01EN(I/OModules)
PaperlessRecorderDAQSTATIONDX1000,DX2000:RefertoGS04L41B01-01E,GS04L42B01-01E
DataAcquisitionSystemGM:RefertoGS04L55B01-01EN,GS04L53B01-01EN(I/OModules)
DataAcquisitionUnitMW100:Refer to GS 04M10A01-01E
<RelatedDocuments>FieldWirelessSystemOverview:
Refer to GS 01W01A01-01EN<Trademarks>All the brand names or product names of Yokogawa Electric used in this document are either trademarks or registered trademarks of Yokogawa Electric Corporation.Company and product names used in this manual are trademarks or registered trademarks of their respective holders.The company and product names used in this manual are not accompanied by the trademark or registered trademark symbols (" ™ " and " ® ").