YES Slim & YES Super Series CommerCial DC inverter vrF air-ConDitioners You Can trust
-
Table of Contents
Serving your needs since 1874 1
Product Benefits 3
Product Features 4
Product Functions 8
Product Technologies 11
Indoor Units 21
Smart Control 27
Fresh Air System 31
Product Nomenclature 33
Product Portfolio 34
Product Specifications 36
-
YES Slim & YES Super | 1
A century of innovation
Established in 1874 in York, Pennsylvania, YORK has
helped our customers meet their temperature control
needs for over a century.
Now a Johnson Controls brand, YORK continues to
benefit customers through research that has gone on to
claim several significant firsts in design and innovation.
Johnson Controls is able to provide our customers with
the best temperature control solutions available around
the world today.
Pioneer in Inverter technology
Our customers can be assured that they will enjoy the
benefits of the latest technology when they choose a
Johnson Controls product, as YORK has always been
at the forefront of adopting new technologies for their
offerings.
From being the first to offer a low pressure VSD unit in
1979 to introducing the inverter technology in the 21st
century, YORK has demonstrated its pioneering spirit.
Leader in reliability
When constructing products, YORK places our
customers needs as the top priority of our design
process.
Our inverter VRF units are produced using state-of-
the-art lean manufacturing techniques, and rigorous
quality testing is implemented at every step of the
manufacturing process, before they are shipped to
customers.
Significant Milestones
1935First to develop a successful single-room air conditioner
1954First to offer year-round air-conditioning
1979launched the first low Pressure vsD Driven Centrifugal Chiller
2004launched the first vsD Driven air Cooled screw Chiller
2005applied vsD in YorK industrial refrigeration screw Chiller
2011launched the Yes mini residential inverter vrF, magnetic vsD Centrifugal Chiller, vsD Driven Water Cooled screw Chiller
2012launched the Yes slim residential/ Commercial inverter vrF, Yes super Commercial inverter vrF
Serving Your Needs Since 1874.
-
2 | YES Slim & YES Super
Endorsed by Iconic Buildings.
2 | YES Slim & YES Super
YORKs HVAC systems have been installed in many of the worlds most famous landmarks. YORK makes sys-
tems for structures of all sizes that bring innovation, comfort and design wherever people live, work and play.
-
YES Slim & YES Super | 3
YORK Variable Refrigerant Flow (VRF)
At Johnson Controls, we always seek to anticipate what customers are looking for and strive to provide the
temperature control systems that will meet their myriad of needs.
YORK VRF air-conditioners offer customers a range of benefits that is unparalleled in the air-conditioner
market.
Energy Efficient
Customers looking to save money will be delighted to know our air-conditioners can help
reduce costs as the highly energy-efficient VRF units will help you decrease the power
you use.
Wide Ambient Range
Customers can take comfort in knowing that our inverter VRF air-conditioners can
operate in extreme weather conditions, running safely even when ambient temperature is
up to 52C for cooling or -20C for heating.
48 to 52C cooling for YES Slim & YES super or -15 to -20C heating for YES Slim will be running at intervals.
Smart Control
Customers can take more effective control of their air-conditioners with a variety of
technology tools available for our units. Our advanced suite of control solutions include:
three types of touch screen controllers, smart home connection and building automation
systems using the Metasys software.
Versatility
We understand that no two customers are the same. Thats why weve designed our
air-conditioning systems to be versatile enough to meet our customers differing needs.
From product selection to installation to commissioning, YORK YES Series offers
impressive flexibility.
Greater Comfort
We know that enjoying comfort at the right temperature is one of our customers
foremost desires. We have the technology to deliver that comfort, including a BLDC
(Brushless Direct Current) fan motor with adjustable speeds, anti-vibration and sound-
insulation technology.
Product Benefits
-
4 | YES Slim & YES Super
Environmental Protection
Our highly energy efficient Inverter VRF units provide environmental protection by
using the eco-friendly R410A refrigerant.
Air Cooled Inverter Driver
They also carry the air cooled inverter driver, a core component which uses air-cooled
heat rejection technology for higher energy efficiency.
Independent Oil Circuit Design
The independent oil circuit design allows the oil balance system to be kept separate from the
cooling and heating operation, thereby avoiding the frequent switching of the compressor and im-
proves sustainability and energy efficiency.
Outdoor unit Outdoor unit
Oil balance pipe between units
Oil transport distribution station
52C -20C
Product Features
Wide Ambient Range
With wide ambient temperatures ranging from 52C in cooling mode to -20C in heat-
ing mode, the outdoor unit can work in any adverse environment
High ESP Discharge Air
The ESP discharge air of the system can reach up to 80 Pa, which guarantees stable
cooling and heating, making it suitable for any outdoor space or machine rooms of multi-
storey structures.
Touch Screen Wired Controller
Take control of your system with our touch screen wired controller that is available in
four different colours. It has a built-in wireless remote controller receiver to control the
indoor unit, as well as a real-time temperature sensor.
-
YES Slim & YES Super | 5
Multi-point Data Collection
Maintain and repair your outdoor units easily with a Service Controller, which allows to
be connected to any indoor unit in the same network to do multi-point data collection.
Outdoor Unit Anti-Corrosion Fins
Our units also have outdoor unit anti-corrosion fins which are made from hydrophilic
aluminium and help the outdoor units defrost quickly and get rid of condensation. The
anti-corrosion coating and wave-shape reduces the cutting surfaces, thereby prolonging
the life of the fin significantly.
Combined Electronic Expansion Valves and Check Valve Throttle Device
With a commitment to fine quality, our VRF units make use of the combined electronic
expansion valves and check valve throttle device which helps to prolong product
usage by reducing the working time of the electronic expansion valve. Our large capac-
ity outdoor units are equipped with double electronic expansion valves, which increase the
response speed of the flow control and heating mode.
Complete System Protection for High Reliability
Our VRF air-conditioners come thoroughly equipped with a complete system protec-
tion for high reliability, which includes:
Communication Fault Protection Inverter Fault Protection
Temperature Sensor Protection Pressure Sensor Protection
Insufficient Refrigerant Protection Compressor Fault Protection
Compressor Overcurrent Protection BLDC Fault Protection
Discharge Temperature Protection Discharge Pressure Protection
Suction Pressure Protection Low Pressure Switch Protection
Intelligent Debugging Operation
With an intelligent debugging operation, an alarm will be triggered if any com-
munication errors are detected between the indoor and outdoor units. Automatic
alerts will also be sent when service stop valves are opened or closed.
Wave-shaped Fin
Decrease cutting surface to reduce corrosion risk
Water do not accumulate in the gap between fins and can drip down easily to reduce corrosion risk.
Water does not accumulate in the gap between fins and can drip down easily to reduce corrosion risk.
-
6 | YES Slim & YES Super
Improved Indoor Air Quality
Nano-TiO2 sterilizers are also in place, which enables up to 95% completion of steriliza-
tion in 6 hours, allowing improved indoor air quality.
Moderate Height Difference Allowance
From installation to commissioning to product selection, YORK YES Series offers
unparalleled flexibility. For example, moderate height difference allowance enables
outdoor units with some height difference to be installed within the same system.
Intelligent Weather-Proofing
You can now maximise comfort throughout the day with our inverter VRF air-condition-
ers as they come with intelligent weather-proofing that allows pressure and tempera-
ture sensors to collect pre/post-defrosting data to derive the optimal defrost setting,
maintaining a high performance in heating and cooling operations under strong winds.
Ultraviolet Photo Catalysis
Nano-TiO2 Nano-TiO2
Polluted Air
Polluted Air
Fresh Air
Refrigerant Connect To Indoor Units
Height Difference Between Modular Less Than 5m
-
YES Slim & YES Super | 7
Double Fan Design and Noise Reduction Technology
The double fan design, which enables a lower airflow volume as compared to a single
fan, and the noise reduction technology, made possible by DC Scroll inverter compres-
sors, BLDC fan motor with adjustable speeds, anti-vibration and sound-insulation tech-
nology, ensures that the air-conditioners operate quietly by cutting down the operational
noise levels.
Non-stop Oil Return at Heating
Through the computation of accumulated operation time, real-time system partial load-
ing, temperature and pressure data, the system can determine when to activate the non-
stop oil return at heating without switching to cooling mode, thereby offering continu-
ous heating to the users.
-
8 | YES Slim & YES Super
Product FunctionsOptimization in Operation of Indoor Units
Our system can detect and promptly compare real-time pressure and temperature pa-
rameters, then optimizes the indoor unit operation by automatically adjusting the pres-
sure and compressor running frequencies.
Intelligent Defrost
Our intelligent defrost system ensures comfort at heating.
Silent Operation Function
The outdoor unit also automatically detects real-time changes in environmental tem-
perature and operation pressure, and adjusts to silent mode accordingly.
Auto-restart Function
In case of accidental power failure, the system auto-restarts and recovers to the former
operation mode.
High PressureSensor
Low PressureSensor
Far end indoor units refrigerant flow increased
Operation mode before power cut off
Automatic restart and Recovery recover to the operation mode before
power cut off
After 1hr
Heat storage and
defrost
Humidity defrost at ultra
extra-low temperatur
e
Defrost on-deman
d by
pressure & tem
perat
ure
Operation mode before power cut off
Automatic restart and recovery to the operation mode
High PressureSensor
Low PressureSensor
Far end indoor units refrigerant flow increased
Operation mode before power cut off
Automatic restart and Recovery recover to the operation mode before
power cut off
After 1hr
Heat storage and
defrost
Humidity defrost at ultra
extra-low temperatur
e
Defrost on-deman
d by
pressure & tem
perat
ure
-
YES Slim & YES Super | 9
LED Display
The diagnosis and display of LED error codes helps shorten service time by technicians.
Refrigerant Recovery
If the indoor unit or outdoor unit fails in the system, the refrigerant can be recovered to
reduce its wastage.
Max Operating Frequency Setting Function
When there is a limited capacity of power distribution, users have the option to set a
maximum compressor frequency ratio, ensuring economical returns and stability.
Can set max compressor frequency
Tackles the lack of power distribution in renovation of buildings
More economical and stable
Better performance in case of a power shortage
Maximum Frequency Limit Operation
Compressor Rotation Operation
The compressor rotation operation effectively spreads the operation time of each
compressor,extending the unit life.
1st Circle:
2nd Circle:
3rd Circle:
-
10 | YES Slim & YES Super
1st Circle:
2nd Circle:
3rd Circle:
Single Modular Combination Units
Stop Running Backup Running Backup Running
Precision
Fast Step Jump
Traditional Inverter Technology
YORK Inverter Technology
Normal 120Communication Square Wave Drive Mode
YORK 180Communication Sine Wave Drive Mode
Phase Current Phase Current
U Phase
V Phase
W Phase
U Phase
V Phase
W Phase
Failed
Failed
Double Backup Operation
If one compressor fails, the other compressor(s) can keep running if no oil contamination
occurs.
If one outdoor unit fails, the other outdoor unit(s) can keep running if no oil contamina-
tion occurs.
-
YES Slim & YES Super | 11
Product TechnologiesStepless Inverter Technology
Our system adopts advanced DC inverter drivers with higher sensitivity, lower power
consumption and lower heat loss. It keeps a good balance between the accuracy of ad-
justment and response time, thereby ensuring a fast response and enough accuracy. The
accuracy of adjustment can reach 0.01HZ, and the capacity can be adjusted steplessly.
1st Circle:
2nd Circle:
3rd Circle:
Single Modular Combination Units
Stop Running Backup Running Backup Running
Precision
Fast Step Jump
Traditional Inverter Technology
YORK Inverter Technology
Normal 120Communication Square Wave Drive Mode
YORK 180Communication Sine Wave Drive Mode
Phase Current Phase Current
U Phase
V Phase
W Phase
U Phase
V Phase
W Phase
Failed
Failed
180DC Inverter Driver Control Technology
YES S Series adopts the advanced phase voltage signal sampling method, and can mea-
sure the force trends of the motor speed and rotor, improving the running efficiency of
the motor through having the DC inverter driver transmit regular sine-curve waves.
There are three groups of terminals in the inverter compressor electric box, providing the
DC inverter driver access to the terminal to drive the stator coil of the DC brushless mo-
tor within the compressor. The connected circuit, under a certain time order, has the DC
motor generate a 360 magnetic field.
A 180 DC inverter control enables the stator coil to always have current steadily running
through to make it stable.
Precision
Fast Step Jump
Traditional Inverter Technology
YORK Inverter Technology
-
12 | YES Slim & YES Super
High Performance Mainboard Chip
Our outdoor units use the ARM CORTEX-M3, which has the 32Bit
72Mhz high-speed chip.
This chip has the highest performance in the industry, and im-
proves the calculation efficiency of the DC inverter while reducing
the power consumption of the transformer or other system parts. 4 8 12 16 20 24 28 32
23
4
a a
b
bc c
1,
2,
3,
1
d
lg p
h
Strong Magnetic Rotor of Compressor Motor
Traditional Compressor Motor
Capacity HP
Time Min
System Refrigerant Circulation Diagram (Pressure-Enthalpy) High Pressure Chamber Scroll Compressor
Other refrigerant system diagramYORK high pressure cell refrigerant system diagram
DC Brushless Fan Motor
DC Brushless Fan Motor
Compressor Inverter Driver
Powerful Permanent Magnets
Our compressor motor rotors use powerful permanent magnets
made from rare earth. Compared with the normal ferrite mag-
nets, it has stronger magnetic and heat resistance, which provides
greater torque, lower power consumption, with higher reliability
and energy efficiency.
DC Inverter Technology
Our YES-S Series outdoor units feature the DC inverter compressor and DC fan motor,
which enable more efficient and quiet operations.
-
YES Slim & YES Super | 13
Soft Start
Variable frequency soft start technology can achieve the required capacity output of
indoor units within a short period.
4 8 12 16 20 24 28 32
23
4
a a
b
bc c
1,
2,
3,
1
d
lg p
h
Strong Magnetic Rotor of Compressor Motor
Traditional Compressor Motor
Capacity HP
Time Min
System Refrigerant Circulation Diagram (Pressure-Enthalpy) High Pressure Chamber Scroll Compressor
Other refrigerant system diagramYORK high pressure cell refrigerant system diagram
DC Brushless Fan Motor
DC Brushless Fan Motor
Compressor Inverter Driver
4 8 12 16 20 24 28 32
23
4
a a
b
bc c
1,
2,
3,
1
d
lg p
h
Strong Magnetic Rotor of Compressor Motor
Traditional Compressor Motor
Capacity HP
Time Min
System Refrigerant Circulation Diagram (Pressure-Enthalpy) High Pressure Chamber Scroll Compressor
Other refrigerant system diagramYORK high pressure cell refrigerant system diagram
DC Brushless Fan Motor
DC Brushless Fan Motor
Compressor Inverter Driver
High Pressure Chamber Scroll Compressor
High pressure chamber scroll compressors directly gets the suction refrigerant from the
indoor unit back to the compression cylinder. The refrigerant is not heated by the mo-
tor, so it can get a better compression ratio and a relatively high energy efficiency. The
pressure of the refrigerant with high temperature and pressure in the crank case can be
adjusted automatically. and then discharged from the exhaust, which has a similar func-
tion as the static pressure box, and allows the noise to be effectively controlled.
High-efficiency Oil Separator
The cover of the oil separator uses a centrifugal rotary steering design. Refrigerant gas
goes into the oil separators and then immediately gains a high rotating speed. This,
together with the centrifugal force separates the heavier oil gas from the refrigerant. The
oil gas is liquefied and finally drops to the storage device across the walls of the separa-
tor, thereby finishing the separation process.
4 8 1216 20 24
28 32
2
3
4
a a
b
bc c
1,
2,
3,
1
d
lg p
h
Strong Magnetic Rotor of Compressor Motor
Traditional Compressor Motor
Capacity HP
Time Min
System Refrigerant Circulation Diagram (Pressure-Enthalpy)
High Pressure Chamber Scroll Compressor
Other refrigerant system diagram
YORK high pressure cell
refrigerant system diagram
DC Brushless Fan Motor
DC Brushless Fan Motor
Compressor Inverter Driver
-
14 | YES Slim & YES Super
Non-stop Compressor, Cross Oil Balance Protection Technology
Through reasonable oil control logic, with the large volume of accumulator (with oil
storage function), and the specific tubing, the system can complete the cross oil bal-
ance protection process. The compressor does not need to stop throughout the whole
process, making the operation of the air-conditioning system more reliable and efficient
while without affecting the indoor effect.
Application of Oil balance on Single Unit
Application of Oil balance on combined units
Discharge
Suction
ON
2
1ONOFF
OFF
SV Close SV Open
YORK Chiller Multiple Deep Oil Separating Technology
YORK Inverter VRF Double Oil Separating Technology
Oil separator in condenser
Evaporator
Discharge pipeInside oil separation
Double oil separation pipeline
Compressor
Filter
Liquid supply line
Evap
orator oil
return pipe
Nozzle with injector
Triple oil separation pipeline
Suction pipe
Ref. routeOil route
Compressor discharge
Compressor, with oil separation function inside
First oil separation
System discharge
Compressor suction
Oil se
parator
Accum
ulator
System suction (liquid)
Oil return
Double oil separation
High pressure sensor
Flow of refrigerant
High pressure discharge chamber
Connected to low pressure suction end of asymmetric vortex plate
Pressure-difference oil pipe
The formation of continuous oil film
Oil balance between the unit inside compressors: After the oil in the second compressor is separat-ed in the oil separator, it will enter the crank case oil groove in the first compressor by oil pipe, and after the oil in the first compressor is separated in the oil separator, it will enter the accumulator oil groove by pipe. Oil will be transported to two compressors by suction pipe, so the compressor does not need to stop and ensure that two compressors can gain lubrication by oil at the same time.
Oil balance between modules uses the pressure-difference method. After separation in the oil seperator, the oil is divided into two branches, with one of them flowing to the liquid separator and the other one going into another module. The oil pressure in oil separator is high and the oil pressure in liquid is low. When the solenoid valve in branch to another module (1) is open, and the solenoid valve in liquid separator pipe of another module (2) is open, the differential pressure will automatically engage the oil from oil separator of the first module to liquid separator of the second module, thus completing the oil balance between modules.
-
YES Slim & YES Super | 15
Double Oil Separation Technology
This technology ensures the compressor is neither in short nor excessive supply of oil,
thereby guaranteeing high reliability and efficiency. Since deep oil separation technology
has been in application on large variable frequency chillers for many years, inverter VRF
also refers to the experience of large systems, using double oil cleaning technology. The
compressor has an oil separation function, and a newly added high-efficiency oil separa-
tor to do double oil separation at the same time.
Application of Oil balance on Single Unit
Application of Oil balance on combined units
Discharge
Suction
ON
2
1ONOFF
OFF
SV Close SV Open
YORK Chiller Multiple Deep Oil Separating Technology
YORK Inverter VRF Double Oil Separating Technology
Oil separator in condenser
Evaporator
Discharge pipeInside oil separation
Double oil separation pipeline
Compressor
Filter
Liquid supply line
Evap
orator oil
return pipe
Nozzle with injector
Triple oil separation pipeline
Suction pipe
Ref. routeOil route
Compressor discharge
Compressor, with oil separation function inside
First oil separation
System discharge
Compressor suction
Oil se
parator
Accum
ulator
System suction (liquid)
Oil return
Double oil separation
High pressure sensor
Flow of refrigerant
High pressure discharge chamber
Connected to low pressure suction end of asymmetric vortex plate
Pressure-difference oil pipe
The formation of continuous oil film
Application of Oil balance on Single Unit
Application of Oil balance on combined units
Discharge
Suction
ON
2
1ONOFF
OFF
SV Close SV Open
YORK Chiller Multiple Deep Oil Separating Technology
YORK Inverter VRF Double Oil Separating Technology
Oil separator in condenser
Evaporator
Discharge pipeInside oil separation
Double oil separation pipeline
Compressor
Filter
Liquid supply line
Evap
orator oil
return pipe
Nozzle with injector
Triple oil separation pipeline
Suction pipe
Ref. routeOil route
Compressor discharge
Compressor, with oil separation function inside
First oil separation
System discharge
Compressor suction
Oil se
parator
Accum
ulator
System suction (liquid)
Oil return
Double oil separation
High pressure sensor
Flow of refrigerant
High pressure discharge chamber
Connected to low pressure suction end of asymmetric vortex plate
Pressure-difference oil pipe
The formation of continuous oil film
Over Compression Prevention Technology
The load and requirement of refrigerant in VRF systems are changing. As the load volume
can influence frequency, whether the system is intelligent makes a big difference.
1. The system uses a high-pressure sensor to detect the
discharge pressure, then adjusts the fan motor to ensure the
discharge pressure does not exceed the allowable range.
2. Pressure relief vents are available in the compressor cylinder.
When over-compression happens, the corresponding
pressure-relief vents will be automatically pushed against the
linked spring to release pressure and refrigerant gas, thereby
preventing over compression.
Application of Oil balance on Single Unit
Application of Oil balance on combined units
Discharge
Suction
ON
2
1ONOFF
OFF
SV Close SV Open
YORK Chiller Multiple Deep Oil Separating Technology
YORK Inverter VRF Double Oil Separating Technology
Oil separator in condenser
Evaporator
Discharge pipeInside oil separation
Double oil separation pipeline
Compressor
Filter
Liquid supply line
Evap
orator oil
return pipe
Nozzle with injector
Triple oil separation pipeline
Suction pipe
Ref. routeOil route
Compressor discharge
Compressor, with oil separation function inside
First oil separation
System discharge
Compressor suction
Oil se
parator
Accum
ulator
System suction (liquid)
Oil return
Double oil separation
High pressure sensor
Flow of refrigerant
High pressure discharge chamber
Connected to low pressure suction end of asymmetric vortex plate
Pressure-difference oil pipe
The formation of continuous oil film
-
16 | YES Slim & YES Super
Continuous Oil Film Lubricating Technology
The oil supply in the compressor is pow-
ered by the pressure difference in the high-
pressure chamber and creates consistently
stable oil film adherent to the wall, pro-
moting the effective lubrication between
the moving and fixed scrolls, sealing of
compression chamber, cooling of the wall
of the cavity, etc and reducing the friction
loss and noise in the operation.
Application of Oil balance on Single Unit
Application of Oil balance on combined units
Discharge
Suction
ON
2
1ONOFF
OFF
SV Close SV Open
YORK Chiller Multiple Deep Oil Separating Technology
YORK Inverter VRF Double Oil Separating Technology
Oil separator in condenser
Evaporator
Discharge pipeInside oil separation
Double oil separation pipeline
Compressor
Filter
Liquid supply line
Evap
orator oil
return pipe
Nozzle with injector
Triple oil separation pipeline
Suction pipe
Ref. routeOil route
Compressor discharge
Compressor, with oil separation function inside
First oil separation
System discharge
Compressor suction
Oil se
parator
Accum
ulator
System suction (liquid)
Oil return
Double oil separation
High pressure sensor
Flow of refrigerant
High pressure discharge chamber
Connected to low pressure suction end of asymmetric vortex plate
Pressure-difference oil pipe
The formation of continuous oil film
%
RPM
100
080
060
040
020
0100 200 300 400 500 600 700 800 900 1000
BLDC Motor
AC Motor
Effic
ienc
y
Speed
Internal tread piping
Gas refrigerant
Gas refrigerant
Gas refrigerant
Liquid refrigerant
Liquid refrigerant
Liquid refrigerant
Traditional ref. circuit design
New-type ref. circuit design
Increase liquid status to improve heat exchange efficient
GasGas-liquid mixture
Liquid
3-row heat-exchanger
Up to 20C sub-cooling
Ref.
Intelligent Refrigerant Storage Technology
1. Through the high and low pressure sensors which control the amount of compres-
sion and discharge of the compressor, the excess refrigerant is stored in the pipeline
of the system.
2. The accumulator provides storage space required for both defrosting and oil return,
thus preventing the compressor from operating with liquid slugging. This ensures that
the system runs with higher reliability and stability.
Powerful Permanent Magnets
Outdoor dual fans are configured with high efficient, low noise BLDC motor and up to
40-step air-flow adjustment, enabling more accurate unit capacity output.
-
YES Slim & YES Super | 17
Integral Design of Axial-flow Fan & Fan Guide Technology
According to our research, reduction of the axial-flow fan blades and fan guide space can
enhance the aerodynamic performance. When the ratio of tip clearance and fan diameter
decreases from 3% to 1%, air flow can increase by 10%, thus improving the efficiency of
the fan motor and reducing noise.
%
RPM
100
080
060
040
020
0100 200 300 400 500 600 700 800 900 1000
BLDC Motor
AC Motor
Effic
ienc
y
Speed
Internal tread piping
Gas refrigerant
Gas refrigerant
Gas refrigerant
Liquid refrigerant
Liquid refrigerant
Liquid refrigerant
Traditional ref. circuit design
New-type ref. circuit design
Increase liquid status to improve heat exchange efficient
GasGas-liquid mixture
Liquid
3-row heat-exchanger
Up to 20C sub-cooling
Ref.
%
RPM
100
080
060
040
020
0100 200 300 400 500 600 700 800 900 1000
BLDC Motor
AC Motor
Effic
ienc
y
Speed
Internal tread piping
Gas refrigerant
Gas refrigerant
Gas refrigerant
Liquid refrigerant
Liquid refrigerant
Liquid refrigerant
Traditional ref. circuit design
New-type ref. circuit design
Increase liquid status to improve heat exchange efficient
GasGas-liquid mixture
Liquid
3-row heat-exchanger
Up to 20C sub-cooling
Ref.
%
RPM
100
080
060
040
020
0100 200 300 400 500 600 700 800 900 1000
BLDC Motor
AC Motor
Effic
ienc
y
Speed
Internal tread piping
Gas refrigerant
Gas refrigerant
Gas refrigerant
Liquid refrigerant
Liquid refrigerant
Liquid refrigerant
Traditional ref. circuit design
New-type ref. circuit design
Increase liquid status to improve heat exchange efficient
GasGas-liquid mixture
Liquid
3-row heat-exchanger
Up to 20C sub-cooling
Ref.
2. The pipe is processed with internal tread piping that can add more turbulence to the
flow of the refrigerant and enlarge the heat-exchanging surface. Also, it adopts cor-
rugated expansion-connected fins to add air passageway and heat transmission of
the gas on the air-cooling side.
3. The advanced 2-in and 1-out circuit design can increase the proportion of liquid
refrigerant and the heat exchanging rate of the refrigerant, thereby enhancing heat
exchanging effect and efficiency.
High-efficiency Heat Exchanger
1. For large-capacity units, it uses 3-row
heat-exchangers to improve heat
emission in summer and endothermic
ability in winter to ensure the heat
exchange effect.
-
18 | YES Slim & YES Super
High-efficiency Plate Heat Exchanger Sub-cooling Technology
In order to ensure long piping's performance, a plate-type heat exchanger is used as a
sub-cooler to achieve up to 20C sub-cooling temperature.
%
RPM
100
080
060
040
020
0100 200 300 400 500 600 700 800 900 1000
BLDC Motor
AC Motor
Effic
ienc
y
Speed
Internal tread piping
Gas refrigerant
Gas refrigerant
Gas refrigerant
Liquid refrigerant
Liquid refrigerant
Liquid refrigerant
Traditional ref. circuit design
New-type ref. circuit design
Increase liquid status to improve heat exchange efficient
GasGas-liquid mixture
Liquid
3-row heat-exchanger
Up to 20C sub-cooling
Ref.
Intelligent Piping Length Adaption Technology
The system mainly uses high and low pressure as data for control. As for long piping,
indoor electronic expansion valve and outdoor sub-cooling can self-adapt in accordance
with the target low pressure, which can not only ensure long-distance delivery of cooling
capacity, but also solve the problem of bias indoor flow, sparing human setting codes for
pipe length, increasing integral comfort of the room and considerably saving debugging
work during installation.
Automatically close to target pressure
Automatically determine pressure loss
Automatically improve capacity correction
Target pressure
Long pipinginstallation
-
YES Slim & YES Super | 19
8 6 4 2 0 -2 -4 -6 -8 -10
Automatically close to target pressure
Automatically determine pressure loss
Automatically improve capacity correction
Target pressure
Long piping installation
Chronic freezing, intelligent extra low temperature defrost
Frosting reaches a certain level, defrosting
No frost, no need to defrost
Frosting probability
Chronic freezing probability
Environmental temperature
Defrost cycle and strength adaption
Heating Capacity
Time
DefrostHeating
Heating
Below -3 Intellige
nt
Defrost
Over -
3 Intelligent Defrost
Outdoor coil
Indoor unit
Accumulator
Adjust electronic expansion valve
Indoor unit begins heat storage
Reduce low temperature refrigerant
Intelligent Defrost Technology
1. YORKs unique heat storage defrost technology
Before entering the defrost operation, the system will store an amount of heat for
defrost later. (This operation does not compromise the indoor comfort).
So it can reduce the liquid refrigerant return flow while defrosting, and can let the
refrigerant carry more calories and evaporate faster. This results in faster defrosting
by 50% compared to regular systematic defrosting.
It can also speed up the the heating after defrosting for better comfort. By contribut-
ing to the normal operation of compressors, it can ensure the system running stably
and reliably, increasing the defrost efficiency and the actual energy efficiency of the
whole system.
2. Defrost on demand
Our outdoor unit design has high-
accuracy pressure and temperature
sensors. Through close cooperation,
they can detect the changes in
system data caused by outdoor
unit frosting, such as the pressure,
temperature, duration of time, etc. and
then calculate the thickness of frost
8 6 4 2 0 -2 -4 -6 -8 -10
Automatically close to target pressure
Automatically determine pressure loss
Automatically improve capacity correction
Target pressure
Long piping installation
Chronic freezing, intelligent extra low temperature defrost
Frosting reaches a certain level, defrosting
No frost, no need to defrost
Frosting probability
Chronic freezing probability
Environmental temperature
Defrost cycle and strength adaption
Heating Capacity
Time
DefrostHeating
Heating
Below -3 Intellige
nt
Defrost
Over -
3 Intelligent Defrost
Outdoor coil
Indoor unit
Accumulator
Adjust electronic expansion valve
Indoor unit begins heat storage
Reduce low temperature refrigerant
intelligently.
Only when the thickness gets up to a certain level will the unit begin to defrost,
tackling problems like "frequent defrosting" or "incomplete defrosting".
-
20 | YES Slim & YES Super
3. Extra low temperature intelligent defrost
When the outdoor temperature is below -3C, the outdoor humidity is very low,
and the air conditioning is generally not easy to frost, but easy to chronically form a
sheet of ice. After some time, this will cause ice accumulation.
In such circumstances, the system will enable extra low temperature intelligent
defrost mode, which can solve the problems of chronic icing and avoid frost free
defrost.
4. For high-humidity environments, it can run through varieddefrost cycles with
different strengths.
Pressure & Temperature Combined Control
Our system has a full range of sensors including high pressure, low pressure, discharge
temperature, heat exchanger temperature, environmental temperature, suction tem-
perature, coil outlet temperature, and liquid pipe temperature sensors. Comprehensive
safeguards can make the system more efficient, stable, reliable and comfortable.
8 6 4 2 0 -2 -4 -6 -8 -10
Chronic freezing, intelligent extra low temperature defrost
Frosting probability
Chronic freezing probability
Environmental temperature
-
YES Slim & YES Super | 21
Indoor Units
Round-way Cassette
Blind angles of air distribution
Minified blind angles 360good air distribution
Oblique view Elevation view
Fresh air Intake
Blind angles of air distribution
Minified blind angles 360good air distribution
Oblique view Elevation view
Fresh air Intake
Blind angles of air distribution
Minified blind angles 360good air distribution
Oblique view Elevation view
Fresh air Intake
Blind angles of air distribution
Minified blind angles 360good air distribution
Oblique view Elevation view
Fresh air Intake
360 degree circulation
Room temperature, airflow, and noise control are
regulated and maintained throughout the room.
Different height setting
Normal ceiling mode or high ceiling mode can be set
by wired controllers to achieve effectiveness and com-
fort ability at the same time.
Fresh air intake
Fresh air can be introduced directly.
Brushless Direct Current (BLDC) fan motor
With BLDC motor, the fan speed can be adjusted to
reduce the noise and improve the efficiency.
High efficiency drainage pump
The drainage pump is available with 750mm head.
-
22 | YES Slim & YES Super
(Unit: mm)
Ceiling
Compact Ducted Indoor Unit
Compact design
With a height of just 200mm and depth of 450mm,
its compact size makes installation ideal for narrow
spaces such as corridor of bedrooms or hotel rooms.
Flexible air return
The air return baffle is detachable. The direction of
air return can be adjusted during installation, either
downward or backward.
ESP adjustable
The external static pressure of the ceiling-packaged
indoor unit is adjustable, supporting different installa-
tions and delivering optimal airflow.
Sleep mode
Sleep mode can be selected via a wired controller.
Optional drainage pump
The ceiling-packaged indoor unit fits in the narrowest
of spaces where the drainage pump is not required.
However, if there is enough room in the ceiling and the
drainage distance is long, a drainage pump is available.
700mm
Part ceilingNarrow corridor installation
450mm
1.8kW~7.1kW0~30Pa
2.0kW~5.3kW
6.6kW~11.5kW
14kW~17.5kW
15~80Pa
15~100Pa
0~30Pa
-
YES Slim & YES Super | 23
700mm
Part ceilingNarrow corridor installation
(Unit: mm)
Ceiling
Ceiling-packaged Duct (Low Static)
Compact design
With a height of just 200mm and depth of 450mm,
its compact size makes installation ideal for narrow
spaces such as corridor of bedrooms or hotel rooms.
Flexible air return
The air return baffle is detachable. The direction of
air return can be adjusted during installation, either
downward or backward.
ESP adjustable
The external static pressure of the ceiling-packaged
indoor unit is adjustable, supporting different installa-
tions and delivering optimal airflow.
Sleep mode
Sleep mode can be selected via a wired controller.
Optional drainage pump
The ceiling-packaged indoor unit fits in the narrowest
of spaces where the drainage pump is not required.
However, if there is enough room in the ceiling and the
drainage distance is long, a drainage pump is available.
1.8kW~5.3kW
6.6kW~11.5kW
14kW~17.5kW
15~80Pa
15~100Pa
0~30Pa
2.0kW~5.3kW
6.6kW~11.5kW
14kW~17.5kW
15~80Pa
15~100Pa
0~30Pa
-
24 | YES Slim & YES Super
230mm
600mm
730~1334mm
Fast heating
Auxiliary electric heater is optional for the ceiling packaged indoor unit to meet consumers needs. It also speeds up the pace at which the room warms up after switching on the air-conditioner.
Sleep mode
Compact and quiet, the ceiling packaged indoor unit is ideal for
locations where noise is sensitive, such as bedrooms. Sleep mode can
be selected via a wired controller.
Drainage pump is optional
(Unit: mm)
CeilingThe ceiling packaged indoor unit is extra- slim and fits in the
narrowest of spaces where drainage pump is not required.
However, if there is enough room in the ceiling and the drainage
distance is long, a drainage pump is optional for selection.
1.8kW~5.3kW
6.6kW~11.5kW
14kW~17.5kW
15~80Pa
15~100Pa
0~30Pa
2.0kW~5.3kW
6.6kW~11.5kW
14kW~17.5kW
15~80Pa
15~100Pa
0~30Pa
Floor-concealed Indoor Unit
Medium Static Duct
Complete product line
Four models ranging from 2.8kW to 7.1kW are available for selection.
Compact design
A compact design with a uniform 230mm depth &
600mm height is adopted for all models, and is suit-
able for floor-concealed installations in cabinets
ESP adjustable
The external static pressure of the ceiling-concealed
indoor unit is adjustable, supporting different installa-
tions and delivering optimal airflow.
Sleep mode
Sleep mode can be selected via a wired controller.
Better air distribution
Our special 45-degree angle design for the air outlets
helps to optimize air distribution for both cooling &
heating.
B
Side air outlet
A
Top air outlet York air outlet
-
YES Slim & YES Super | 25
520mm
310mm
840~1440mm
Max=500mm
Standard
2-Way Cassette
High Wall Indoor Unit
Complete product line
Seven models ranging from 2.8kW to 11.2kW are available for selection.
Complete product line
Five models ranging from 2.2kW to 7.1kW are available for selection. Suitable for residential & light commercial
applications with their compact sizes and attractive design.
Compact design
A compact design with uniform 520mm depth and
310mm height is adopted for all models, making in-
stallations easier.
Standard drainage pump
The unit has a standard drainage pump capable of
draining water up to 500mm, and is ideal for draining
condensation over longer distances.
Whole Package Design
Electronic Expansion Valve (EEV) fitted inside the unit
chamber makes it a package design, doing away with
the need for external installations.
Low noise
High efficiency/low noise motors and fan impellers are
adopted to enable quiet operation down to 28dB(A). In
addition, there is a standard filter for a healthier use.
-
26 | YES Slim & YES Super
240mm
680mm
1245~1670mm
Max=500mm
Option
Floor/CeilingComplete product line
Eight models ranging from 2.8kW to 11.2kW are available for selection. Floor and
ceiling installations are convertible for job sites.
Compact design
A compact design with uniform 240mm depth and
680mm height is adopted for all models, making in-
stallations easier.
Optional drainage pump
An optional drainage pump for a ceiling installation is
available. It is capable of draining water up to 500mm,
and is ideal for draining condensation over longer
distances.
-
YES Slim & YES Super | 27
Smart Control
Gray Sky blue Green Brown
Wired Controller
Wireless Controller
Group Control
Individual Control
Group Control
Individual & group control
Every indoor unit in the YES system can be controlled via the wired and wireless control-
lers. Whats more, the wired controller has a group control function and can connect up
to four indoor units.
Our touch screen wired controllers come in multiple color options, and are equipped with
TiO2 control and wireless controller receivers.
-
28 | YES Slim & YES Super
Central on/off control at the entrance/exit
On/Off Controller
Our touch screen on/off controllers can connect up to 256 indoor units or 4 VRF systems.
It can turn on or off the indoor units within the same zone at the same time.
Central Controller
Our 7-inch touch screen central controller can be mounted on the wall easily. It can
connect up to 1,024 indoor units/512 groups/128 zones/16 VRF systems, and can achieve
the same control functions as the wired controller. In addition, it has a weekly schedule
function.
ON/OFF controller which can support Modbus or BACnet protocol for different application (need to choose the corresponding type of the controller).
Central controller can support Modbus or BACnet protocol for different ap-plication (need to select the protocol mode).
** YDHW/YDCC can't connect to on/off controller.
** YDHW/YDCC cant connect to central controller.
-
YES Slim & YES Super | 29
Pull out the door card
Insert the door card
Door Card
Door Card
Door Card
Pull out the door card
Insert the door card
Door Card
Door Card
Door Card Function
A door card on/off signal function is available on the YES indoor unit control board and
features two selection modes. Users can choose one of the two functions shown below
by using the door card and signal interface communication.
Mode 1
The system returns to the last operation mode automatically when the card is inserted.
Mode 2
The system has to be switched on manually when the card is inserted, so as to reduce
any wastage of electricity.
-
30 | YES Slim & YES Super
BAS Connection
Our YES Series can be connected to the Building Automation System for an integrated
smart control solution.
Metasys/Other BAS System BACnet
communication board
NAE Converter (JCI)
BACne
t
BACnet/IP
** YDHW/YDCC cant connect to BAS connection.
-
YES Slim & YES Super | 31
LOW HIGH
Hot ambient Mild ambient Cold ambient
Single-Connection Multi-Connection with Mixed Types
(Fresh air & standard type indoor)Multi-Connection
with All Fresh Air Type Indoor
Fresh Air SystemComplete Product Line
There are 10 models ranging from 510m3/h to 6000m3/h available and are suitable for
residential and commercial applications.
High ESP (External Static Pressure)
The maximum ESP is up to 300Pa for long duct design of large space applications.
Wide Ambient Range
YORK Fresh Air Units can work in conditions with ambient temperatures from -7 to
46C, capable of running all year round.
Energy-saving Mode
Under auto mode, fresh air units can switch to ventilation automatically at mild ambient,
thus reducing energy consumption.
Three Connection Types
For all models, 1 fresh air indoor unit can be connected to 1 outdoor unit.
For models 0510/1080 /1680/2100, multi indoor units (all fresh air type or mixed types)
are allowed to connect to 1 outdoor unit.
-
32 | YES Slim & YES Super
Default2500hours
Unlimited
150hours
9000hours
1250hours
5000hours
Mediumpollution
Heavypollution
DefaultMild
pollution
Connection conditions:
1. For all models: the capacity ratio of indoor units (including fresh air) must be 80%
100% .
2. For multi-connection with mixed types, the capacity ratio of fresh air units must be
below 30%.
3. For single-connection type, the outdoor model is fixed (and cannot be changed).
Filter Cleaning Alarm
There are six time interval options and three air pollution levels for filter cleaning alarm
setting.
-
YES Slim & YES Super | 33
100 0 A 1
Y: YORK
Condition 1: Export T1
Design Series No.
Design Code
Power Supply M: 380-415V/3-50Hz E:380V/3-50Hz
Outdoor Unit Type S:Single Unit V: Modular Unit
Refrigerant E:R410A
V: DC Inverter
O: Outdoor Unit
H: Heat Pump
Cooling Capacity Code
Structure H:Horizoatal Discharge V: Top Discharge
Y:YORK
D: Variable Refrigerant Flow(VRF) Air Conditioner
Cooling Capacity Code in 100W
Indoor Unit Type, CC: Medium Static Ducted
Mode of Operation, C: Cooling Only, H: Heat Pump
Auxiliary Electric Heater 0: No Heater, 2: With 2# Heater, 4: With 4# Heater
Power Supply, A: 220V/1PH-50Hz
Design Code
Design Series Number: C Series(R410A)
Condition, 3: Export T3
Expansion Device, E: Internal
Piping, L:Left, R: Rightl
Return Plenum, F: With Back Return Plenum and Filter
2F L E CH 3
0 E 3
Y:YORK
D:Variable Refrigerant Flow(VRF) Air Conditioner
Cooling Capacity Code in 100W Air Flow Rate (M3/h) for YDCF
Indoor Unit Type,CD: Compact Ducted, CP: Ceiling Packaged Ducted (Low Static), CK: Round-way Ceiling Cassette,
DK: 2-way Ceiling Cassette, EC: Floor/Ceiling, VC: Floor Conceal , HW: High Wall, CF: Fresh Air
Mode of Operation, C: Cooling Only, H: Heat Pump
Auxiliary Electric Heater 0: No Heater, 2: With 2# Heater, 4: With 4# Heater
Power Supply A: 220V/1PH-50Hz, E: 380V/3PH-50Hz
Design Code
Design Series Number: E Series(R410A)
Condition, 1: Export T1; 3: Export T3
Expansion Device, N: Internal EXV No Drainage Pump, P: Interal EXV With Drainage Pump
Outdoor Units
E Series Indoor Units
C Series Indoor Units
Product Nomenclature
-
34 | YES Slim & YES Super
YES Slim Outdoor Unit Line-up
Product Portfolio
Capacity Model Cooling Capacity Heating Capacity Appearance
8 HP YVOH080HSEM 22.4kW 25.0kW
10HP YVOH100HSEM 28.0kW 31.5kW
12 HP YVOH120HSEM 33.5kW 35.0kW
Indoor
Cooling Capacities kW
Types 1.8 2.2 2.5 2.8 3.2 3.6 4 4.5 5 5.6
Compact Ducted Y Y Y Y Y Y Y Y Y Y
Low Static Duct (YDCP) Y Y Y Y Y Y Y Y Y Y
Medium Static Ducted (YDCC)* Y Y Y Y Y
High Wall (YDHW) Y Y Y Y
Floor/Ceiling (YDEC) Y Y Y Y
Floor-Concealed (YDVC) Y Y Y
2-Way Cassette (YDDK) Y Y Y Y
Round Way Cassette (YDCK) Y Y Y Y Y Y
Cooling Capacities kW
Types 6.3 7.1 8 9 10 11.2 12.5 14 17.5
Compact Ducted Y Y
Low Static Duct (YDCP) Y Y Y Y Y Y
Medium Static Ducted (YDCC)* Y Y Y Y Y Y
High Wall (YDHW) Y
Floor/Ceiling (YDEC) Y Y Y Y
Floor-Concealed (YDVC) Y
2-Way Cassette (YDDK) Y Y Y
Round Way Cassette (YDCK) Y Y Y Y Y Y Y Y
*approximate data
-
YES Slim & YES Super | 35
Capacity Cooling Capacity
YVOH 080VVEE
YVOH 100VVEE
YVOH 120VVEE
YVOH 140VVEE
YVOH 160VVEE
YVOH 180VVEE
20HP - 2 - - - -
22HP - 1 1 - - -
24HP - - 2 - - -
26HP - - 1 1 - -
28HP - - 1 - 1 -
30HP - - - 1 1 -
32HP - - - - 2 -
34HP - - - - 1 1
36HP - - - - - 2
38HP - - 2 1 - -
40HP - - 2 - 1 -
42HP - - 1 1 1 -
44HP - - 1 - 2 -
46HP - - - 1 2 -
48HP - - - - 3 -
50HP - - - - 2 1
52HP - - - - 1 2
54HP - - - - - 3
Recommended Combination of Outdoor Units
Capacity Model Cooling Capacity Heating Capacity Product
8 HP YVOH080VVEE 25.2kW 28.0kW
10HP YVOH100VVEE 28.0kW 31.5kW
12 HP YVOH120VVEE 33.5kW 37.5kW
14HP YVOH140VVEE 40.0kW 45.0kW
16HP YVOH160VVEE 45.0kW 50.0kW
18HP YVOH180VVEE 50.0kW 56.0kW
YES Super Outdoor Unit Line-up
Outdoor single modular consists of two types:
Single-fan and double-fan models are available.
With 2 HP increments, the outdoor unit can meet various capacity requirements.
-
36 | YES Slim & YES Super
YES Slim Outdoor
Note:
1. Cooling conditions: indoor 27CDB/ 19CWB, outdoor 35CDB, equivalent length 10m, IU/OU height difference 0m.
2. Heating conditions: indoor 20CDB, outdoor 7CDB/6CWB, equivalent length 10m, IU/OU height difference 0m.
3. Noise data is tested in semi-anechoic chamber and converted to equivalent anechoic chamber data. The actual noise data could vary per differ-ent installation and working conditions.
Outdoor Unit ModelYVOH
080HSEMYVOH
100HSEMYVOH
120HSEM
HP 8HP 10HP 12HP
Power Supply (V/Ph/Hz) 380415/3/50 380415/3/50 380415/3/50
Capacity (kW)Cooling 22.4 28.0 33.5
Heating 25.0 31.5 35.0
Power (kW)Cooling 6.19 7.36 9.74
Heating 5.71 7.34 8.75
Compressor Output
(kW)Nominal 4.80 6.00 7.20
Air Flow (m3/h) - 9000 9000 10 000
Dimensions (mm) HWD 1600 1100 400 1600 1100 400 1600 1100 400
Weight (kg) Net Weight 180 200 200
RefrigerantType R410A R410A R410A
Charge (kg) 6.0 6.6 6.6
Noise (dB(A))Anechoic Sound Level 53 56 58
Semi-Anechoic Sound Level 56 59 61
Piping (mm)Liquid 9.52 9.52 12.70
Gas 19.05 22.23 25.40
Current (A)
Max Current 20.50 23.00 26.00
Breaker Current 25.00 32.00 32.00
Cooling nominal current 10.11 12.02 15.91
Heating nominal current 9.33 11.99 14.30
Product Specifications
-
YES Slim & YES Super | 37
YES Super Basic
Outdoor Unit ModelYVOH
080VVEEYVOH
100VVEEYVOH
120VVEEYVOH
140VVEEYVOH
160VVEEYVOH
180VVEE
HP 8HP 10HP 12HP 14HP 16HP 18HP
Power Supply (V/Ph/Hz) 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50
Capacity (kW) Cooling 25.2 28.0 33.5 40.0 45.0 50.0
Heating 28.0 31.5 37.5 45.0 50.0 56.0
Power (kW)Cooling 6.59 7.51 9.50 10.77 11.57 15.25
Heating 6.65 7.79 10.4 10.96 12.43 14.86
Compressor Output
(kW)Nominal 5.25 6.00 7.20 9.10 10.2 11.6
Air Flow (m3/h) Cooling/Heating 10 500 10 500 10 500 17 500 17 500 17 500
Dimensions (mm) HWD 1700 1000 760 1700 1300 760
Weight (kg) Net Weight 210 210 225 295 310 315
RefrigerantType R410A
Charge (kg) 8.0 8.0 8.5 10.0 10.0 10.5
Noise (dB(A))
Anechoic Sound Level 57 58 59 60 60 61
Semi-Anechoic Sound
Level60 61 62 63 63 64
Piping (mm)Liquid 9.52 9.52 12.7 12.7 12.7 15.88
Gas 19.05 22.23 25.4 25.4 28.58 28.58
Current (A)
Max Current 17.0 19.0 23.0 28.0 31.0 33.0
Breaker Current 25.0 25.0 32.0 40.0 40.0 50.0
Cooling nominal current 10.6 12.0 15.2 17.2 18.4 24.1
Heating nominal current 10.7 12.5 16.6 17.6 19.8 23.6
-
38 | YES Slim & YES Super
Recommended Combination Unit
Outdoor Unit ModelYVOH100
+YVOH100
YVOH100 +
YVOH120
YVOH120 +
YVOH120
YVOH120 +
YVOH140
YVOH120 +
YVOH160
YVOH140 +
YVOH160
HP 20HP 22HP 24HP 26HP 28HP 30HP
Power Supply (V/Ph/Hz) 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50
Capacity (kW)Cooling 56.0 61.5 67.0 73.5 78.5 85.0
Heating 63.0 69.0 75.0 82.5 87.5 95.0
Power (kW)Cooling 15.02 17.01 19.00 20.27 21.07 22.34
Heating 15.58 18.19 20.80 21.36 22.83 23.39
Compressor Output
(kW)Nominal 12.0 13.2 14.4 16.3 17.4 19.3
Air Flow (m3/h) Cooling/Heating 21 000 21 000 21 000 28 000 28 000 35 000
Dimensions (mm) HWD(1700 1000
760) 2
(1700 1000
760) 2
(1700 1000
760) 2
(1700 1000
760)
+
(1700 1300
760)
(1700 1000
760)
+
(1700 1300
760)
(1700 1000
760)
+
(1700 1300
760)
Weight (kg) Net Weight 420 435 450 520 535 605
RefrigerantType R410A R410A R410A R410A R410A R410A
Charge (kg) 16.0 16.5 17.0 18.5 18.5 20
Noise (dB(A))
Anechoic Sound Level 61 61 62 62 62 63
Semi-Anechoic Sound
Level64 64 65 65 65 66
Piping (mm)
Liquid 15.88 15.88 15.88 19.05 19.05 19.05
Gas 28.58 28.58 28.58 34.9 34.9 34.9
Oil Balance 6.35 6.35 6.35 6.35 6.35 6.35
Current (A)
Max Current 38.0 42.0 46.0 51.0 54.0 59.0
Breaker Current 50.0 63.0 63.0 63.0 80.0 80.0
Cooling nominal current 24.0 27.2 30.4 32.4 33.6 35.6
Heating nominal current 25.0 29.1 33.2 34.2 36.4 37.4
-
YES Slim & YES Super | 39
Outdoor Unit ModelYVOH160
+ YVOH160
YVOH160 +
YVOH180
YVOH180 +
YVOH180
YVOH120 +
YVOH120 +
YVOH140
YVOH120 +
YVOH120 +
YVOH160
YVOH120 +
YVOH140 +
YVOH160
HP 32HP 34HP 36HP 38HP 40HP 42HP
Power Supply (V/Ph/Hz) 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50
Capacity (kW) Cooling 90.0 95.0 100.0 107.0 112.0 118.5
Heating 100.0 106.0 112.0 120.0 125.0 132.5
Power (kW)Cooling 23.14 26.82 30.50 29.77 30.57 31.84
Heating 24.86 27.29 29.72 31.76 33.23 33.79
Compressor Output (kW) Nominal 20.4 21.8 23.2 23.5 24.6 26.5
Air Flow (m3/h) Cooling/Heating 35 000 35 000 35 000 38 500 38 500 45 500
Dimensions (mm) HWD(1700 1300
760) 2
(1700 1300
760) 2
(1700 1300
760) 2
(1700 1000
760) 2
+
(1700 1300
760)
(1700 1000
760)
2 +
(1700 1300
760)
(1700 1000
760)
+ 2
(1700 1300
760)
Weight (kg) Net Weight 620 625 630 745 760 830
RefrigerantType R410A R410A R410A R410A R410A R410A
Charge (kg) 20.0 20.5 21.0 27.0 27.0 28.5
Noise (dB(A))
Anechoic Sound Level 63 63 64 64 64 64
Semi-Anechoic Sound
Level66 66 67 67 67 67
Piping (mm)
Liquid 19.05 19.05 19.05 19.05 19.05 19.05
Gas 34.9 34.9 38.1 38.1 38.1 38.1
Oil Balance 6.35 6.35 6.35 6.35 6.35 6.35
Current (A)
Max Current 62.0 64.0 66.0 74.0 77.0 82.0
Breaker Current 80.0 80.0 100.0 100 100 100
Cooling nominal current 36.8 42.5 48.2 47.6 48.8 50.8
Heating nominal current 39.6 43.4 47.2 50.8 53.0 54.0
Recommended Combination Unit
-
40 | YES Slim & YES Super
Outdoor Unit Model
YVOH120 +
YVOH160 +
YVOH160
YVOH140 +
YVOH160 +
YVOH160
YVOH160 +
YVOH160 +
YVOH160
YVOH160 +
YVOH160 +
YVOH180
YVOH160 +
YVOH180 +
YVOH180
YVOH180 +
YVOH180 +
YVOH180
HP 44HP 46HP 48HP 50HP 52HP 54HP
Power Supply (V/Ph/Hz) 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50
Capacity (kW)Cooling 123.5 130.0 135.0 140.0 145.0 150.0
Heating 137.5 145.0 150.0 156.0 162.0 168.0
Power (kW)Cooling 32.64 33.91 34.71 38.39 42.07 45.75
Heating 35.26 35.82 37.29 39.72 42.15 44.58
Compressor Output
(kW)Nominal 27.6 29.5 30.6 32.0 33.4 34.8
Air Flow (m3/h) Cooling/Heating 45 500 52 500 52 500 52 500 52 500 52 500
Dimensions (mm) HWD
(1700 1000
760)
+
2 (1700
1300 760)
(1700 1300
760)
3
(1700 1300
760)
3
(1700 1300
760)
3
(1700 1300
760)
3
(1700 1300
760)
3
Weight (kg) Net Weight 845 915 930 935 940 945
RefrigerantType R410A R410A R410A R410A R410A R410A
Charge (kg) 28.5 30.0 30.0 30.5 31.0 31.5
Noise (dB(A))
Anechoic Sound Level 64 65 65 65 65 66
Semi-Anechoic Sound
Level67 68 68 68 68 69
Piping (mm)
Liquid 19.05 19.05 19.05 19.05 19.05 19.05
Gas 38.1 38.1 38.1 38.1 38.1 38.1
Oil Balance 6.35 6.35 6.35 6.35 6.35 6.35
Current (A)
Max Current 85.0 90.0 93.0 95.0 97.0 99.0
Breaker Current 100 125.0 125.0 125.0 125.0 125.0
Cooling nominal current 52.0 54.0 55.2 60.9 66.6 72.3
Heating nominal current 56.2 57.2 59.4 63.2 67.0 70.8
Note:
1. Cooling conditions: indoor 27CDB/ 19CWB, outdoor 35CDB, equivalent length 10m, IU/OU height difference 0m.
2. Heating conditions: indoor 20CDB, outdoor 7CDB/6CWB, equivalent length 10m, IU/OU height difference 0m.
3. Noise data is tested in semi-anechoic chamber and converted to equivalent anechoic chamber data. The actual noise data could vary per differ-ent installation and working conditions.
4. For combined models, clrcult breaker should be installed for not only the main power supply, but also the power supply of each module.
-
YES Slim & YES Super | 41
Compact Ducted Indoor Unit
Indoor Unit ModelYDCD018H0NA
YDCD022
H0NA
YDCD025H0NA
YDCD028H0NA
YDCD032
H0NA
YDCD036H0NA
Power Supply (V/Ph/Hz) 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50
Capacity (kW)
Cooling 1.8 2.2 2.5 2.8 3.2 3.6
Heating 2.2 2.5 2.8 3.2 3.6 4.0
Power Input (W) 37 37 46 46 48 50
Current (A) Nominal 0.16 0.16 0.2 0.2 0.21 0.22
Air Flow (m3/h) - 350 350 450 450 480 480
ESP (Pa)Standard
(min-max)0(0-30) 0(0-30) 0(0-30) 0(0-30) 0(0-30) 0(0-30)
Dimensions (mm) HWD 200X700X450200X700X450
200X700X450
200X700X450
200X700X450
200X700X450
Weight (kg) Net Weight 23 23 23 23 23 25
Noise (dB(A)) H/M/L 29/25/23 29/25/23 31/27/25 31/27/25 32/29/27 32/29/27
Piping (mm)
Liquid/Gas 6.35/9.52 6.35/9.52 6.35/9.52 6.35/9.52 6.35/12.70 6.35/12.70
Drainage DN25 DN25 DN25 DN25 DN25 DN25
Indoor Unit ModelYDCD040H0NA
YDCD045H0NA
YDCD050H0NA
YDCD056H0NA
YDCD063H0NA
YDCD071
H0NA
Power Supply (V/Ph/Hz) 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50
Capacity (kW)
Cooling 4.0 4.5 5.0 5.6 6.3 7.1
Heating 4.5 5.0 5.6 6.3 7.1 8.0
Power Input (W) 70 70 76 106 106 110
Current (A) Nominal 0.3 0.3 0.33 0.46 0.48 0.48
Air Flow (m3/h) - 560 560 750 900 900 990
ESP (Pa)Standard
(min-max)0(0-30) 0(0-30) 0(0-30) 0(0-30) 0(0-30) 0(0-30)
Dimensions (mm) HWD 200X700X450200X900X450
200X900X450
200X900X450
200X1100X450
200X1100X450
Weight (kg) Net Weight 25 30 34 34 34 34
Noise (dB(A)) H/M/L 38/35/32 35/32/29 35/32/29 39/36/32 37/34/31 37/35/32
Piping (mm)
Liquid/Gas 6.35/12.70 6.35/12.70 6.35/12.70 6.35/12.70 9.52/15.88 9.52/15.88
Drainage DN25 DN25 DN25 DN25 DN25 DN25
-
42 | YES Slim & YES Super
Indoor Unit ModelYDCP
036H0NAYDCP
040H0NAYDCP
045H0NAYDCP
050H0NAYDCP
056H0NAYDCP
063H0NA
Power Supply (V/Ph/Hz) 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50
Capacity (kW)Cooling 3.6 4.0 4.5 5.0 5.6 6.3
Heating 4.0 4.5 5.0 5.6 6.3 7.1
Power Input (W) 50 70 70 76 106 106
Current (A) Nominal 0.22 0.3 0.3 0.33 0.46 0.48
Air Flow (m3/h) Cooling/Heating 480 560 560 750 900 900
ESP (Pa)Standard (min
max)0 (030) 0 (030) 0 (030) 0 (030) 0 (030) 0 (030)
Dimensions (mm) HWD 200 700 620 200900620 2001100620
Weight (kg) Net Weight 25 25 25 30 34 34
Noise (dB(A)) H/M/L 30/27/25 35/32/29 35/32/29 33/31/28 37/34/30 35/33/29
Piping (mm)Liquid/Gas 6.35/12.7 6.35/12.7 6.35/12.7 6.35/12.7 6.35/12.7 9.52/15.88
Drainage DN25
Indoor Unit Model YDCP071H0NA YDCP080H0NA YDCP090H0NA YDCP100H0NA YDCP112H0NA
Power Supply (V/Ph/Hz) 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50
Capacity (kW)Cooling 7.1 8.0 9.0 10.0 11.2
Heating 8.0 9.0 10.0 11.2 12.5
Power Input (W) 110 138 206 260 260
Current (A) Nominal 0.48 0.60 0.90 1.25 1.25
Air Flow (m3/h) Cooling/Heating 990 1200 1500 1700 1700
ESP (Pa)Standard (min
max)0 (030) 15 (040) 15 (040) 15 (040) 15 (040)
Dimensions (mm) HWD 2001100620 2001100620 220 1450 620
Weight (kg) Net Weight 34 34 48 48 48
Noise (dB(A)) H/M/L 36/33/30 39/36/31 39/36/31 41/37/33 41/37/33
Piping (mm)Liquid/Gas 9.52/15.88 9.52/15.88 9.52/15.88 9.52/15.88 9.52/15.88
Drainage DN25
Indoor Unit Model YDCP018H0NA YDCP022H0NA YDCP025H0NA YDCP028H0NA YDCP032H0NA
Power Supply (V/Ph/Hz) 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50
Capacity (kW)Cooling 1.8 2.2 2.5 2.8 3.2
Heating 2.2 2.5 2.8 3.2 3.6
Power Input (W) 37 37 46 46 48
Current (A) Nominal 0.16 0.16 0.20 0.20 0.21
Air Flow (m3/h) Cooling/Heating 350 350 450 450 480
ESP (Pa)Standard (min
max)0 (030) 0 (030) 0 (030) 0 (030) 0 (030)
Dimensions (mm) HWD 200 700 620 200 700 620 200 700 620 200 700 620 200 700 620
Weight (kg) Net Weight 23 23 23 23 23
Noise (dB(A)) H/M/L 27/25/23 27/25/23 28/26/24 28/26/24 30/27/25
Piping (mm)Liquid/Gas 6.35/9.52 6.35/9.52 6.35/9.52 6.35/9.52 6.35/12.7
Drainage DN25
Ceiling Packaged Duct (Low Static)
-
YES Slim & YES Super | 43
Medium Static Duct
Indoor Unit ModelYDCC
020H0FLEAYDCC
025H0FLEAYDCC
034H0FLEAYDCC
045H0FLEAYDCC
053H0FLEAYDCC
066H0FLEA
Power Supply (V/Ph/Hz) 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50
Capacity (kW)Cooling 2.0 2.5 3.4 4.5 5.3 6.6
Heating 2.2 3.0 3.9 4.95 5.8 6.8
Power Input (W) 40 55 75 100 110 185
Current (A) Nominal 0.35 0.35 0.40 0.46 0.52 0.96
Air Flow (m3/h) Standard 380 450 600 800 930 1200
ESP (Pa)Standard (min
max)15 (0/15/30) 15 (0/15/30) 15 (0/15/30) 15 (0/15/30) 15 (0/15/30) 15 (15/40/80)
Dimensions (mm) HWD 226 855 602 226 855 602226 1055
602
226 1175
602
226 1175
602
245 1475
576
Weight (kg) Net Weight 20 20 23 25 25 32
Piping (mm) Liquid/Gas 6.35/9.52 6.35/9.52 6.35/12.7 6.35/12.7 6.35/12.7 9.52/15.88
Drainage Piping (mm) DN25
Indoor Unit ModelYDCC
078H0FLEAYDCC
095H0FLEAYDCC
115H0FLEAYDCC
140H0FLEAYDCC
175H0FLEA
Power Supply (V/Ph/Hz) 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50
Capacity (kW)Cooling 7.8 9.5 11.5 14.0 17.5
Heating 8.2 11.0 13.0 16.5 19.0
Power Input (W) 215 270 300 420 510
Current (A) Nominal 1.08 1.29 1.30 1.90 2.11
Air Flow (m3/h) Standard 1360 1600 1900 2200 2700
ESP (Pa)Standard (min
max)15 (15/40/80) 15 (15/40/80) 15 (15/40/80) 15 (15/50/100) 15 (15/50/100)
Dimensions (mm) HWD 245 1475 576 245 1805 576 245 1805 576 430 1563 655 430 1563 655
Weight (kg) Net Weight 33 41 41 58 65
Piping (mm) Liquid/Gas 9.52/15.88 9.52/15.88 9.52/15.88 9.52/15.88 9.52/15.88
Drainage Piping (mm) DN25
-
44 | YES Slim & YES Super
Round-way Cassette
Indoor Unit ModelYDCK
028H0PAYDCK
036H0PAYDCK
040H0PAYDCK
045H0PAYDCK
050H0PAYDCK
056H0PAYDCK
063H0PA
Power Supply (V/Ph/Hz) 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50
Capacity (kW)Cooling 2.8 3.6 4.0 4.5 5.0 5.6 6.3
Heating 3.2 4.0 4.5 5.0 5.6 6.3 7.1
Power Input (W) 17 19 19 19 26 27 42
Current (A) Nominal 0.13 0.15 0.15 0.15 0.22 0.28 0.37
Air Flow (m3/h) Standard 780 810 810 810 900 960 1100
Dimensions (mm)
Unit (HWD)246 840
840
246 840
840
246 840
840
246 840
840
246 840
840
246 840
840
246 840
840
Panel (HWD)50 950
950
50 950
950
50 950
950
50 950
950
50 950
950
50 950
950
50 950
950
Weight (kg)Unit 23 23 23 23 26 26 26
Panel 5.5 5.5 5.5 5.5 5.5 5.5 5.5
Noise (dB(A)) H/M/L 28/27/25 29/28/26 29/28/26 29/28/26 31/29/27 32/31/28 32/31/28
Piping (mm)Liquid/Gas 6.35/9.52 6.35/12.7 6.35/12.7 6.35/12.7 6.35/12.7 6.35/12.7 9.52/15.88
Drainage DN25
Indoor Unit ModelYDCK
071H0PAYDCK
080H0PAYDCK
090H0PAYDCK
100H0PAYDCK
112H0PAYDCK
125H0PAYDCK
140H0PA
Power Supply (V/Ph/Hz) 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50
Capacity (kW)
Cooling 7.1 8.0 9.0 10.0 11.2 12.5 14.0
Heating 8.0 9.0 10.0 11.2 12.5 14.0 16.0
Power Input (W) 42 63 63 129 129 142 171
Current (A) Nominal 0.37 0.54 0.54 1.07 1.07 1.17 1.39
Air Flow (m3/h) Standard 1100 1500 1500 1900 1900 2010 2010
Dimensions (mm)
Unit (HWD)246 840
840
288 840
840
288 840
840
288 840
840
288 840
840
288 840
840
288 840
840
Panel (HWD)50 950
950
50 950
950
50 950
950
50 950
950
50 950
950
50 950
950
50 950
950
Weight (kg)
Unit 26 29 29 29 29 29 32
Panel 5.5 5.5 5.5 5.5 5.5 5.5 5.5
Noise (dB(A)) H/M/L 35/31/28 38/35/32 38/35/32 45/39/36 45/39/36 47/43/38 48/45/42
Piping (mm)
Liquid/Gas 9.52/15.88 9.52/15.88 9.52/15.88 9.52/15.88 9.52/15.88 9.52/15.88 9.52/15.88
Drainage DN25
-
YES Slim & YES Super | 45
High Wall
Indoor Unit ModelYDHW
022H0NAYDHW
028H0NAYDHW
036H0NAYDHW
056H0NAYDHW
071H0NA
Power Supply (V/Ph/Hz) 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50
Capacity (kW)Cooling 2.2 2.8 3.6 5.6 7.1
Heating 2.8 3.2 4.0 6.3 7.15
Power Input (W) 35 35 40 50 70
Current (A) Nominal 0.18 0.18 0.23 0.25 0.35
Air Flow (m3/h) Standard 450 450 570 730 1050
Dimensions (mm) HWD 295 890 215 295 890 215 295 890 215 302 1070 220 302 1070 220
Weight (kg) Net Weight 14 14 14 16 16
Noise (dB(A)) H/M/L 34/30/26 34/30/26 38/35/31 44/41/39 44/41/39
Piping (mm)Liquid/Gas 6.35/9.52 6.35/9.52 6.35/12.7 6.35/12.7 9.52/15.88
Drainage DN20
2-way Cassette
Indoor Unit ModelYDDK
028H0PAYDDK
036H0PAYDDK
045H0PAYDDK
056H0PAYDDK
071H0PAYDDK
090H0PAYDDK
112H0PA
Power Supply (V/Ph/Hz) 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50
Capacity (kW)Cooling 2.8 3.6 4.5 5.6 7.1 9.0 11.2
Heating 3.2 4.0 5.0 6.3 8.0 10.0 12.5
Power Input (W) 60 62 68 85 94 129 175
Current (A) Nominal 0.27 0.28 0.31 0.39 0.43 0.59 0.80
Air Flow (m3/h) Standard 500 600 770 900 1160 1500 1700
Dimensions (mm)
Unit (HWD)310 840
520
310 840
520
310 960
520
310 960
520
310 1200
520
310 1440
520
310 1440
520
Panel (HWD)30 1083
630
30 1083
630
30 1203
630
30 1203
630
30 1443
630
30 1683
630
30 1683
630
Weight (kg)Unit 41 41 47 47 53 65 65
Panel 6 6 7 7 8 9 9
Noise (dB(A)) H/M/L 34/28/22 35/32/27 38/33/28 40/36/34 42/38/35 42/38/35 46/43/38
Piping (mm)Liquid/Gas 6.35/9.52 6.35/12.7 6.35/12.7 6.35/12.7 9.52/15.88 9.52/15.88 9.52/15.88
Drainage DN25
-
46 | YES Slim & YES Super
Floor-concealed
Indoor Unit ModelYDVC
028H0NAYDVC
045H0NAYDVC
056H0NAYDVC
071H0NA
Power Supply (V/Ph/Hz) 220/1/50 220/1/50 220/1/50 220/1/50
Capacity (kW)Cooling 2.8 4.5 5.6 7.1
Heating 3.2 5.0 6.3 8.0
Power Input (W) 41 50 60 71
Current (A) Nominal 0.18 0.23 0.27 0.32
Air Flow (m3/h) Standard 420 680 900 1000
Dimensions (mm) HWD 600 730 230 600 980 230 600 1334 230 600 1334 230
Weight (kg) Net Weight 20 24 30 31
Noise (dB(A)) H/M/L 35/32/30 35/32/30 36/33/31 37/34/32
Piping (mm)Liquid/Gas 6.35/9.52 6.35/12.7 6.35/12.7 9.52/15.88
Drainage DN25
Floor/Ceiling
Indoor Unit ModelYDEC
028H0NAYDEC
036H0NAYDEC
045H0NAYDEC
056H0NAYDEC
071H0NAYDEC
080H0NAYDEC
090H0NAYDEC
112H0NA
Power Supply (V/Ph/Hz) 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50
Capacity (kW)Cooling 2.8 3.6 4.5 5.6 7.1 8.0 9.0 11.2
Heating 3.2 4.0 5.0 6.3 8.0 9.0 10.0 12.5
Power Input (W) 110 110 130 130 180 210 210 210
Current (A) Nominal 0.55 0.55 0.65 0.65 0.83 0.97 0.97 1.20
Air Flow (m3/h) Standard 600 600 950 950 1250 1550 1550 1950
Dimensions
(mm)HWD
680 1245
240
680 1245
240
680 1245
240
680 1245
240
680 1245
240
680 1245
240
680 1245
240
680 1670
240
Weight (kg)Net
Weight36 36 36 36 36 38 38 51
Noise (dB(A)) H/M/L 37/33/30 37/33/30 46/44/41 46/44/42 47/45/42 52/48/46 52/48/46 52/48/46
Piping (mm)Liquid/Gas 6.35/9.52 6.35/12.7 6.35/12.7 6.35/12.7 9.52/15.88 9.52/15.88 9.52/15.88 9.52/15.88
Drainage DN25
Note:
1. Cooling conditions: indoor 27CDB/ 19CWB, outdoor 35CDB, equivalent length 10m, IU/OU height difference 0m.
2. Heating conditions: indoor 20CDB, outdoor 7CDB/6CWB, equivalent length 10m, IU/OU height difference 0m.
3. Noise data is tested in semi-anechoic chamber and converted to equivalent anechoic chamber data. The actual noise data could vary per dif-ferent installation and working conditions.
-
YES Slim & YES Super | 47
Fresh Air Indoor
Indoor Unit ModelYDCF0510H0NA
YDCF1080H0NA
YDCF1680H0NA
YDCF2100H0NA
YDCF2500H0NA
Power Supply (V/Ph/Hz) 220/1/50 220/1/50 220/1/50 220/1/50 380/3/50
Capacity (kW)
Cooling 7.1 14.0 22.4 28.0 28.0
Heating 3.5 7.5 10.0 12.0 14.0
Heating* 4.4 9.3 12.8 15.4 18.2
Power Input (W) 110 250 390 530 740
Current (A) Nominal 0.5 1.1 1.9 2.3 2.0
Air Flow (m3/h) Standard 510 1080 1680 2100 2500
ESP (Pa) Standard/High 50/100 100/200 150/220 150/220 150/200/300
Dimensions (mm) HWD 1105 650 220 820 850 480 1406 850 480 1406 850 480 1406 850 508
Weight (kg) Net Weight 34 70 110 110 110
Noise (dB(A)) Standard/High 34/40 36/41 43/46 44/47 40/50/51
PipingLiquid/Gas (mm) 9.52/15.88 9.52/15.88 9.52/22.23 9.52/22.23 9.52/22.23
Drainage (mm) DN25 DN25 DN32 DN32 DN32
Connect to YES outdoor unit (HP) 854 854 854 1054 10
Indoor Unit ModelYDCF3000
H0NEYDCF3500H0NE
YDCF4000H0NE
YDCF5000H0NE
YDCF6000H0NE
Power Supply (V/Ph/Hz) 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50
Capacity (kW)
Cooling 28.0 40.0 45.0 56.0 56.0
Heating 16.0 20.0 21.0 26.0 32.0
Heating* 21.0 26.3 27.6 34.1 42.0
Power Input (W) 1050 950 1260 1580 2310
Current (A) Nominal 2.3 2.5 2.7 3.6 4.3
Air Flow (m3/h) Standard 3000 3500 4000 5000 6000
ESP (Pa) Standard/High 200/300 200/300 200/300 200/300 200/300
Dimensions (mm) HWD 1406 850 508 1680 850 670 1680 850 670 2000 850 670 2000 850 670
Weight (kg) Net Weight 110 170 170 210 210
Noise (dB(A)) Standard/High 51/54 51/54 53/55 54/56 56/57
PipingLiquid/Gas (mm) 9.52/22.23 12.7/25.4 12.7/28.6 15.88/28.6 15.88/28.6
Drainage (mm) DN32 DN40
Connect to YES outdoor unit (HP) 10 14 16 20 20
Note:1. Cooling capacity is based on ambient temperature 33C DB, 28C WB.2. Heating capacity is based on ambient temperature 7C DB, 6C WB; model with open * mark is based on ambient temperature 0C DB, -3C
WB; 3. Cooling default temperature is set as 18C, heating default temperature is set as 25C (0510-2100) or 22C (2500-6000); 4. Outdoor ambient temperature range is -7C46C DB;5. Models below 2100m3/h can adopt mixed connection with indoor units, but the capacity of fresh air unit cannot be over 30% of the outdoor
capacity;6. Models below 2100m3/h can adopt multiple connections to YES outdoor unit (all fresh air system), but the capacity ratio should be between
80%100%;7. Models over 2500m3/h cannot use multi-connection and mixed connection type. They can only use one-to-one connection to the outdoor unit.
-
48 | YES Slim & YES Super
Notes
-
Notes
-