XL 640 07-05-16€¦ · O/150616/V1. Throughput of 640 tests per hr. with ISE (Na/K/Cl/Li) Direct...

4
TRANSASIA BIO-MEDICALS LTD. Transasia House, 8 Chandivali Studio Road, Andheri (E), Mumbai - 400 072 Tel.: (022) 4030 9000, Fax : (022) 2857 3030 Email : [email protected] Website : www.transasia.co.in Twitter :https://twitter.com/transasia_1 ERBA Diagnostics Mannheim GmbH Mallaustrasse 69-73 68219 Mannheim, Germany Telephone : (+49) 621 8799770 Fax : (+49) 621 8799688 Email : [email protected] Website : www.erbamannheim.com Technology Redefined TECHNICAL SPECIFICATIONS System Type Automated, Discrete, Random Access, Paent Priorized, Clinical Chemistry Analyzer Throughput 400 photometric tests/hour and 640 tests/hour with ISE Programmable Parameters Unlimited Photometric Tests & calculaon Items, Serum Indices 3/4 ISE tests Analycal Methods 1 point, 2 point, Rate A, Rate B Photometer Monochromac and Bi-chromac Measurement. 12 Prefixed wavelengths from the photometric range of 340 - 800 nm (340, 376, 415, 450, 480, 505, 546, 570, 600, 660, 700, 750 & 800 nm) O.D. Range 0-3.0 Absorbance Sample Disc 82 Posions, all posions open for samples, STAT samples, calibrator (standards), controls and ISE soluons. Sample Pipeng 2-70 µl in steps of 0.1 µl Probes Dedicated sample probe and 2 probes for Reagents Capacitance based liquid level sensing and VOD. Clot detecon for sample Probe Sample Container Can hold primary tubes and sample cups. Reagent tray 56 posions. 28 Posions each for 20 ML and 50 ML boles Reagent Pipeng 10-300 µl adjustable in 1 µl step. Barcode Reader Both for sample and reagent trays (Oponal) Reacon Tray 72 reusable hard glass cuvees maintained at 37°C ± 0.2° Reading Volume 180 µl Quality Control Levey Jennings Quality Control Program and Twin Plot, Q.C. Rules Diluon Rao 1 : 10 to 1: 100 Light source Halogen Lamp 12 V/ 20 W Detector Stac Silicon Photodiodes Water Consumpon Up to 13 ltrs per hour System Interface RS 232 Bidireconal for PC Interface Penum IV or Higher Power Requirement AC 110 V ±10% Hz and 60 ±1 Hz or AC 220 V ±10 % Hz and 50±1 Hz (Factory set) 800 VA Excluding PC, Printer Monitor Dimensions Approximately 910 mm (w) x 780 mm (D) x 1160 mm(H) Weight Approximately 200 Kg. Note: As part of Product Improvement above specificaon subject to change without prior noce. TBM/BIO/XL640/BRO/150616/V1

Transcript of XL 640 07-05-16€¦ · O/150616/V1. Throughput of 640 tests per hr. with ISE (Na/K/Cl/Li) Direct...

Page 1: XL 640 07-05-16€¦ · O/150616/V1. Throughput of 640 tests per hr. with ISE (Na/K/Cl/Li) Direct ISE measurements Na/K/Cl/Li E E E E E ... 120706 121051 121020 120707 120624 120261

TRANSASIA BIO-MEDICALS LTD.Transasia House, 8 Chandivali Studio Road, Andheri (E), Mumbai - 400 072Tel.: (022) 4030 9000, Fax : (022) 2857 3030 Email : [email protected] Website : www.transasia.co.in Twitter :https://twitter.com/transasia_1

ERBA Diagnostics Mannheim GmbHMallaustrasse 69-73 68219 Mannheim, GermanyTelephone : (+49) 621 8799770 Fax : (+49) 621 8799688Email : [email protected] Website : www.erbamannheim.com

Technology Redefined

T E C H N I C A L S P E C I F I C A T I O N S

System Type Automated, Discrete, Random Access, Pa�ent Priori�zed,

Clinical Chemistry Analyzer

Throughput 400 photometric tests/hour and 640 tests/hour with ISE

Programmable Parameters Unlimited Photometric Tests & calcula�on Items,

Serum Indices 3/4 ISE tests

Analy�cal Methods 1 point, 2 point, Rate A, Rate B

Photometer Monochroma�c and Bi-chroma�c Measurement.

12 Prefixed wavelengths from the photometric range of

340 - 800 nm

(340, 376, 415, 450, 480, 505, 546, 570, 600, 660, 700, 750 & 800 nm)

O.D. Range 0-3.0 Absorbance

Sample Disc 82 Posi�ons, all posi�ons open for samples, STAT samples, calibrator

(standards), controls and ISE solu�ons.

Sample Pipe�ng 2-70 µl in steps of 0.1 µl

Probes Dedicated sample probe and 2 probes for Reagents

Capacitance based liquid level sensing and VOD.

Clot detec�on for sample Probe

Sample Container Can hold primary tubes and sample cups.

Reagent tray 56 posi�ons. 28 Posi�ons each for 20 ML and 50 ML bo�les

Reagent Pipe�ng 10-300 µl adjustable in 1 µl step.

Barcode Reader Both for sample and reagent trays (Op�onal)

Reac�on Tray 72 reusable hard glass cuve�es maintained at 37°C ± 0.2°

Reading Volume 180 µl

Quality Control Levey Jennings Quality Control Program and Twin Plot, Q.C. Rules

Dilu�on Ra�o 1 : 10 to 1: 100

Light source Halogen Lamp 12 V/ 20 W

Detector Sta�c Silicon Photodiodes

Water Consump�on Up to 13 ltrs per hour

System Interface RS 232 Bidirec�onal for PC Interface Pen�um IV or Higher

Power Requirement AC 110 V ±10% Hz and 60 ±1 Hz or

AC 220 V ±10 % Hz and 50±1 Hz (Factory set)

800 VA Excluding PC, Printer Monitor

Dimensions Approximately 910 mm (w) x 780 mm (D) x 1160 mm(H)

Weight Approximately 200 Kg.

Note: As part of Product Improvement above specifica�on subject to change without prior no�ce. TBM

/BIO

/XL6

40

/BR

O/1

50

61

6/V

1

Page 2: XL 640 07-05-16€¦ · O/150616/V1. Throughput of 640 tests per hr. with ISE (Na/K/Cl/Li) Direct ISE measurements Na/K/Cl/Li E E E E E ... 120706 121051 121020 120707 120624 120261

Throughput of 640 tests per hr. with ISE (Na/K/Cl/Li)

Direct ISE measurements Na/K/Cl/Li

E

E

E

E

E

DOAs TDM Immunoturbidimetric Assays

* All chemistries may not be available from ERBA.

Unlimited Test Programmes / Unlimited Profiles

Page 3: XL 640 07-05-16€¦ · O/150616/V1. Throughput of 640 tests per hr. with ISE (Na/K/Cl/Li) Direct ISE measurements Na/K/Cl/Li E E E E E ... 120706 121051 121020 120707 120624 120261

82 positions sample tray

STAT samples can be loaded at any position

Facility to use Primary tubes of 5ml, 7ml,

10ml & sample cups

56 reagent positions with on-board

cooling

50ml & 20 ml reagent bottles

Online inventory management

Multiple reagent positions

72 long life Hard Glass cuvettes

On-board washing station for better

precision & accuracy

Individually replaceable cuvettes

CALIBRATION

REAGENT VOLUME SCREEN

Page 4: XL 640 07-05-16€¦ · O/150616/V1. Throughput of 640 tests per hr. with ISE (Na/K/Cl/Li) Direct ISE measurements Na/K/Cl/Li E E E E E ... 120706 121051 121020 120707 120624 120261

S.NO. PRODUCT CODE PRODUCT NAME METHOD LINEARITY PACK SIZE

1 ALBUMIN BCG 6 g/dl 10 X 44 ML

2 ALP IFCC, AMP 700 U/L R1-2 X 44 ML : R2-2 x 11 ML

3 AMYLASE CNPG3 1500 U/L 5 X 22 ML

4 BID DIAZO 25 mg/dl R1-6X 44ML : R2-3 X 22ML

5 BIT DIAZO 25 mg/dl R1-6X 44ML : R2-3 X 22ML

6 CALCIUM ( A) ARSENAZO 16 mg/dl 10 x 12 ML

7 CHLORIDE MERCURIC THIOCYANATE 130 mEq/L 10 X 12 ML

8 CHOLESTEROL CHOD POD 750 mg/dl 10 X 44ML

9 CK DGKC & IFCC 1000 U/L R1-2 X 44 ML : R2-2 x 11 ML

10 CK MB IMMUNOINHIBITION 1000 U/L R1-2 X 44 ML : R2-2 x 11 ML

11 CREATININE ALKALINE PICRATE 20 mg/dl R1-5 X 44 ML : R2-5 X 11ML

12 GGT SZASZ 500 U/L R1-2 X 44 ML : R2-2 x 11 ML

13 GLUCOSE GOD POD (with mutarotase) 500mg/dl 10 X44 ML

14 HDL DIRECT Modified PEGME 184.8 mg/dl R1-4 x 30 ML : R2-4 x 10ML

15

HBA1c IMMUNOTURBIDIMETRY 18%R1 1 X 4 ML/ R2(a) 1 X 8 ML/

R2 (b) 1 X 4 ML/ R3 2 X 50 ML/

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

LDH-P DGKC 1000 U/L R1-2 X 44 ML : R2-2 x 11 ML

LDL DIRECT IMMUNOINHIBITION 250mg/dl R1-2 X 30ML : R2-2 X 10ML

MAGNESIUM Calmagite 4 mg/dL 2x44 ML

MICROPROTEIN PYROGALLOL RED 400mg/dl 10 X 12 ML

PHOSPHORUS UV PHOSPHOMOLYBDATE 15mg/dl 10 X12 ML

SGOT MODIFIED IFCC 240U/L R1-6 X 44ML : R2-3 X 22ML

SGPT MODIFIED IFCC 240U/L R1-6 X 44ML : R2-3 X 22ML

TOTAL PROTEIN BIURET 16g/dl 10 X 44 ML

TRIGLYCERIDES-SR GPO 600 mg/dL 10 x 44 ML

UREA UREASE GLDH 300mg/dl R1-5 X 44 ML : R2-5 X 11ML

URIC ACID - SR URICASE 25 mg/dl 10 x 44 ML

ERBA NORM NA NA 4 x 5 ML

ERBA PATH NA NA 4 x 5 ML

ERBA AUTO WASH NA NA 10 x 100 ML

120265

121018

121026

120623

120621

120262

120263

121021

120619

120620

121022

121019

120266

120706

121051

121020

120707

120624

120261

120264

120271

120272

120267

121024

121025

121023

120218

120220

120958

120611 XL MULTICAL NA NA 4 X 3 ML

management.

ERBA SYSTEM PACKSQUALITY CONTROL