XENON FOLLOW SPOTLIGHTS
Transcript of XENON FOLLOW SPOTLIGHTS
Front hook Hour meter
SUPERSOL® 2009SR/e
Reduction in size and weight
17% of the weight , 5% of the length, and approximately 10% of the height of the followspot body has been reduced.
High output
With our new high precision reflector and lenses, and reviewing and optimizing our optical design, we have increased the output for 20% at φ1.7m, throw distance 30m, min. spot while reducing weight and size.
Cooling function
We have reduced approx. 30% of the surface temperature by improving the cooling function.
Easy operation
We have improved the ideal body balance, re�ned levers, and handles to remarkably upgrade the user-friendliness and impact resistance.
Compact Xenon lamp
We have a new short-Arc type Xenon lamp especially designed and developed for the new SUPERSOL 2009SR/e.This new minimized lamp has enabled us to design a more compact lamp-house.
New douser cutter
A newly designed blade shape of mechanical dimmer provides a more smooth and more uniformed dimming.We have relocated the moun t i ng pos i t i on to t he ou ts ide o f t he lamp-house in order to provide easy maintenance.
Refined design
The chassis integrated structure has allowed us to reduce the screws and re�ne the body design.
New features.
- Front hook- Lamp hour meter
The leading product of our Xebex Xenon Followspot series is the 2000W model, a highly recognized
product in Japan and in the international market.A color temperature of 6000K, a sharp edged light close
to the natural sunlight with a color rendering rate of Ra 95, enables high performance as a followspot for
concert halls,ball rooms, auditorium and outdoor events.
NOTE: *1 Rectifier not included.*2 Comparison ratio with our conventional product.*3 Rate in ( ) is the striking current*4 100V / 200V
Pursuit of QualityUSHIO LIGHTING, INC. has pushed the limits by pursuing a
perpetual quest for development and diligent effort as a
leading manufacturer.We have packaged our newly evolved
features in an even more compact design.Here, we announce
our new �agship followspot model.
RoHS compliant. *1
*2
*2
*2
Product structure
Spot Head / XPS-2009SR/e
Stand / ST-2009/e
Lamp / UXL-20PRS
Rectifier / KSX-80MHXP/K
Dimensions
Spot head
Max ambient temperature
Max surface temperature
Min throw distance
Min fixture space
Operation angle range
Cord
Weight
Dimensions
Noise
Material
Rated voltage
Rated power
Rated current
Total luminous flux
Color temperature
Cooling
AC input voltage
AC input power
Frequency
AC input current
Input cord
Weight
Dimensions
Color
Material
Weight
Dimensions
Xenon short arc lamp
Rectifier
Stand
40℃
90℃
6m
0.3m
10°upward / 45°downward
DC cord: 2PNCT22mm2 x 2C x 5m
Lamp control cord: 2PNCT1.25mm2 x 6C x5m
51kg
W371xH427xD1422mm
< 48 dB or less (distance 1m)
Aluminum casting and iron pipe
XPS-2009SR/e
UXL-20PRS
DC25V
1,750W
DC70A(Max), Actual current range: 56-70A
64,000lm
Forced air cooling 6-9m/s
Average life 1000hrs
About 6,000K
Single phase 100V-120V,173-240V
KSX-80MHXP/K
< 4.2kVA
50/60Hz
42A(100V) / 21A(200V)
14kg
W180xH375xD420mm
Black (ABS Resin)
2PNCT8mm2 x 3C x5mOne touch connecter
SUPERSOL® 2009SR/e
ST-2009/e
Aluminum casting and iron pipe
50kg
W720xH1145~1480xD628mm
Throw distance (m)
25
30
35
40
45
50
60
70
80
1.45φ
1.7φ
2.0φ
2.3φ
2.55φ
2.9φ
3.4φ
4.0φ
4.6φ
SUPERSOL® 2009SR/ePhotometric data
22,400
15,500
11,400
8,700
6,900
5,600
3,800
2,800
2,100
Spot diameter (m) Illumination intensity (lx)
The above spot diameter is minimum data.The maximum spot diameter(compared with minimum data) is 2times zoom ratio.
*3 *4
●
Photometric data
Throw distance (m)
Spot diameter
30 40 60 80
1.70 2.30 3.40 4.60
25
1.45
15,50022,400 8,700 3,800 2,100
Illumination intensity (lx)
1534
1422
408220
628 720
360360
262
371
427
166
534
1145
~14
80
3E001- 0806
1E002-1102-1k
Safe Use of the product
The product is intended for use in entertainment. Do not use it for any other application than that of entertainment. It is not for use as
general lighting.
As it generates high voltage only use it as speci�ed.
Failure to observe this could result in electric shock or �re.
Use an appropriate stand (�xing bracket) for the weight of the lamphouse.
Failure to observe this could result in the equipment falling over and causing physical damage or personal injury.
When attaching or installing other equipment ensure the minimum distance is maintained between any in�ammable material and the
periphery of the equipment (excluding the direction of radiation) as indicated on the lamphouse and in the instruction manual.
Failure to observe this could result in �re.
Ensure the adequate distance between the light condensing type lighting apparatus and irradiated face is maintained as indicated on the
lamphouse and in the instruction manual.
Failure to observe this could result in the irradiated object catching �re.
The angle at which the equipment can be used is restricted. Use as indicated on the lamphouse and in the instruction manual.
Failure to observe this could result in damage to the equipment and the Xenon lamp blowing.
When attaching or installing the equipment do not allow the power supply cord to be in contact with the lamphouse of the equipment.
Failure to observe this could result in �re.
●
●
●
●
●
●
●
This equipment is intended for use indoors. Do not use it outdoors.
Failure to observe this could result in electric shock or �re.
Use the equipment at the maximum ambient temperature or less.
Failure to observe this could result in damage, deformation, �re or the Xenon lamp blowing.
Do not use the equipment anywhere humid or damp.
Failure to observe this could result in electric shock or �re.
Only use the equipment and power supply box (recti�er) within the allowable ambient temperature.
Failure to observe this could result in the Xenon lamp failing to light up or damage being caused.
Do not use the equipment anywhere unstable or near anything �ammable.
Failure to observe this could result in the equipment falling over and causing a �re or personal injury.
Only use the speci�ed Xenon lamp.
Failure to observe this could result in damage to the equipment or the Xenon lamp blowing.
As the equipment emits a slight amount of ultraviolet light avoid exposure to it for long periods of time.
●
●
●
●
●
●
●
1. Notes on environment / conditions for use
2. Notes on attachment / installationBefore attaching or installing the equipment ensure to thoroughly read the instruction manual and cautionary notes.
After reading store for utilization should the need arise.
Attachment or installation of the equipment should only be carried out by a professional such as a "certi�ed
stage / television lighting engineer".
Failure to observe this could result in malfunction.
Installation should only be carried out by a professional (expert) such as an electrical contractor.
Failure to observe this could result in malfunction.
When attaching and installing the equipment and power supply box (recti�er) they need to have the
appropriate orientation. Attach in accordance with that indicated on the lamphouse and in the
instruction manual.
Failure to observe this could result in damage to the lamphouse, �re or personal injury.
When attaching or installing the equipment ensure measures are implemented to prevent it being
upset and falling by following the instruction manual.
Failure to observe this could result in the equipment falling over and causing physical damage
or personal injury.
When attaching a color changer or other device to the color changer frame, only use a color
changer or other device that is the appropriate weight for the color changer frame.
Failure to observe this could result in physical damage or personal injury.
Avoid stacking power supply boxes (recti�ers) as they could overheat and cause damage or �re.
Ensure to ground (D type grounding) the power supply box (recti�er).
Failure to observe this could result in electric shock or malfunction.
Caution