XENEX EFFECTIVENESS Shadows & Light Reflection Effective UV disinfection cannot rely on reflectivity to reach all surfaces. Each type of surface reflects or absorbs UV light differently. That is why we use Xenex in multiple positions. vs. XENEX: 4 TYPES OF CELLULAR DAMAGE, WHICH PREVENTS CELL REPLICATION PHOTO CROSSLINKING PHOTODIMERIZATION MERCURY: 1 TYPE OF CELLULAR DAMAGE AND ONLY 40% EFFECTIVE 4 PHOTOHYDRATION PHOTOSPLITTING PHOTODIMERIZATION 1 2 3 Shadow areas are being disinfected, but our target is high touch surfaces. 091014 xenex.com | 800-553-0069 NOT ALL UV IS THE SAME. CONTACT US TO LEARN MORE. Lab-Validated Effectiveness Xenex has tested its full spectrum disinfection system on a variety of organisms in several independent labs in the US and internationally. Microorganism Acinetobacter baumannii Aspergillus niger [black mold] Bacillus cereus spores Bacillus globigii spores (anthrax surrogate) Bacillus pumilus spores Bacillus subtilis spores Candida albicans Clostridium difficile (“C. diff”) spores (NAP1) Escherichia coli & E. coli (KREC) Klebsiella oxytoca Klebsiella pneumoniae Methicillin-resistant Staphylococcus aureus (MRSA) MS2 phage Mycobacterium tuberculosis Feline calicivirus (norovirus surrogate) Pseudomonas aeruginosa Proteus mirabilis Proteus morganii Proteus vulgaris Staphylococcus aureus Staphylococcus epidermidis Vancomycin-resistant Enterococci (VRE)

description

Xenex has tested its full spectrum disinfection system on a variety of organisms in several independent labs in the US and internationally.

Transcript of Xenex Effectiveness 091014

Page 1: Xenex Effectiveness 091014

XENEX EFFECTIVENESS

Shadows & Light ReflectionEffective UV disinfection cannot rely on reflectivity to reach all surfaces. Each type of surface reflects or absorbs UV light differently. That is why we use Xenex in multiple positions.

vs.

XENEX: 4 TYPES OF CELLULAR DAMAGE,WHICH PREVENTS CELL REPLICATION

PHOTO CROSSLINKING

PHOTODIMERIZATION

MERCURY: 1 TYPE OF CELLULAR DAMAGEAND ONLY 40% EFFECTIVE

4

PHOTOHYDRATION PHOTOSPLITTING

PHOTODIMERIZATION

1 2

3

Shadow areas are being disinfected, but our target is high touch surfaces.

091014

xenex.com | 800-553-0069

NOT ALL UV IS THE SAME. CONTACT US TO LEARN MORE.

Lab-Validated EffectivenessXenex has tested its full spectrum disinfection system on a variety of organisms in several independent labs in the US and internationally.Microorganism Acinetobacter baumannii Aspergillus niger [black mold]Bacillus cereus sporesBacillus globigii spores (anthrax surrogate) Bacillus pumilus spores Bacillus subtilis spores Candida albicans Clostridium difficile (“C. diff”) spores (NAP1) Escherichia coli & E. coli (KREC) Klebsiella oxytoca Klebsiella pneumoniae Methicillin-resistant Staphylococcus aureus (MRSA)MS2 phageMycobacterium tuberculosisFeline calicivirus (norovirus surrogate)Pseudomonas aeruginosaProteus mirabilisProteus morganiiProteus vulgarisStaphylococcus aureusStaphylococcus epidermidisVancomycin-resistant Enterococci (VRE)

Page 2: Xenex Effectiveness 091014

XENEX EFFECTIVENESS

091014

xenex.com | 800-553-0069

Environmental Effectiveness Studies• 7x more effective than traditional cleaning BMC Infectious Diseases/ April 2014• 16x more effective at deactivating MRSA (Temple VA)• 23% faster than traditional cleaning

• Xenex eliminated all VRE ICHE/Mar 2011 from the environment (MD Anderson Cancer Ctr)

• Bleach removed 70% of C. diff spores while ICAAC Houston/ May 2013 no-bleach clean plus Xenex removed 95% (MD Anderson Cancer Ctr)

NOT ALL UV IS THE SAME. CONTACT US TO LEARN MORE.

Hospital Effectiveness/Patient Outcome Studies53% reduction in HA-C. diff infection rates AJIC/May 2013after 12 months (Cooley Dickinson)

57% reduction in HA-MRSA infection rates JIP/June 2013after 18 months (Moses Cone)

20% reduction HA-C. diff only infection rates AJIC/June 2014 while hitting 22% of discharge rooms (Westchester Medical Center)

Time MattersOften, room turnover time

remains as critical as a pathogen-free patient environment. Mercury system cycle time runs 2 hours and 15 minutes for

C.diff. In contrast, Xenex is proven to clear rooms of

C.diff, VRE, MRSA, and others in 5 minutes. With a total disinfection time of 10 to 15 minutes per room, patients don’t wait.

PULSED XENON

MERCURY CLEANING TIME

vs.15 MINUTES

TOTAL CLEANING TIME

2 HOURS 15 MINUTES

TOTAL CLEANING TIME

(3) 5 MINUTE POSITIONS

(3) 45 MINUTE POSITIONS

MERCURY’S WARM UP/COOL DOWN PROLONGS ROOM DISINFECTION TIME BY A MINIMUM OF 17 MINUTES + THE TIME TO DISINFECT THE ROOM.

2-3 MINUTES WARM UP

15 MINUTES COOL DOWN

Mercury warm up time= 2-3 minutes PLUSan additional 15minutes for cool down

The temperatureof a Mercury bulb

200º

MERCURY