WZP Series
-
Upload
omar-abdussaid -
Category
Documents
-
view
8 -
download
0
description
Transcript of WZP Series
-
075JINGPU
R
WZP and WZPM platinum thermal resistances made by our factory use imported state-or-art production technology and components. For tempera-ture sensor, its inner quality, structure principle, and appearance are kept in class A level.Platinum thermal resistance is a kind of temperature sensor with the feature of accurate, sensitive, and stable performance. Platinum thermal resistance components are inner coil structure made of micro ceramic tube for protection tube, the temperature transducers can be very small (minimum outer diameter can be 1.6mm), so you can produce different types of micro temperature sensor probe.
Application
Working Principle
Jingpu
Max measured current allowed for platinum resistance is 5mA, temperature rise due to this shall be lower than 0.3.
Range specification
Self thermal impact
Diaphragm platinum resistance components are imported products with state-in-art technology in Germany. It have the advantages as accurate, sensitive, short heat response time, stable quality, long use life, etc. Its accuracy can reach level 1/3B.
Diaphragm platinum resistance components
Heat response timeWhen temperature changes with stages, output of thermocouple will be changed to 50% of this stage variation, required time is called heat response time, represented in t0.5.
Platinum Resistance
Platinum Resistance WZP
WZP PT100
PT100
(levelA) -200650allowed deviation (0.15+0.002|t|)
(levelB)-200800allowed deviation (0.30+0.005|t|)
-200800
-200800
Main Technical specification
Type Code Graduating numberMeasurement range
Allowed deviation t
Note: ITI is the absolute value of measured temperature Allowed difference at level A doesnt adapt to temperature range t>650. For level A, platinum resistance is allowed for restricted situation.
Working principle of platinum thermal resistance: resistance of platinum resistance wire can be varied under the action of temperature. It can be directly used to measure the temperature within the range of -200~800. Its advantages: stable electrical performance, relationship between temperature and resistance close to linear, with high accuracy.
Resistance value at 100 for thermal resistance temperature transducers (R100) and resistance at 0 (R0)
Ratio: R100/ R0.Graduating number Pt100: Level A R0 1000.06 Level B R0 1000.12 W100R100/ R01.385
WZP and WZC series thermal resistance components
-
WZP and WZC series thermo resistance components
Mica platinum resistance components, cooper resistance components
076JINGPU
R Jingpu
Heat response time 0.5(S)
Type of thermal resistance
Single platinum thermal resistance temperature transducers
platinum thermalresistance temperaturetransducers
Dual platinumthermal resistance temperature transducers
Cooper thermal resistance temperature transducers
Cooper thermal resistance temperature transducers
WZP-010WZP-011
WZP-035WZC-001
Platinum thermal resistance temperature transducers
Dual platinum thermal resistance temperature transducers
l0(mm)
l1(mm)
Total length L(mm)
Diameted(mm)
Material ofprotectiontube
Product Model
WZP-010
External protective layer
1Cr18Ni9Tistainless
steel sheet
External protective layer
1Cr18Ni9Tistainless
steel sheet
External protective layer
1Cr18Ni9Tistainless
steel sheetExternal
protective layer1Cr18Ni9Tistainless
steel sheet
Pt100
Pt100
-200420
-50100
-50150
-50100
Cu50
Cu50
copper tube
stainless steel
sleeves
stainless steel
sleeves
WZP2-010
WZP-011
WZP2-011
WZC-010
WZP-035
WZC-001
Graduatingnumber
Measurement range
300
Spec.
3504505506509001150140016502150300350450
550
3003504505506509001150140016502150
535
3004
6
8
8
8
12
Pt100-200420
Pt100-200420
Pt100-200420
12
85
65
35 5
30
90
60105
85 60105
80
3025
Note: WZP-0.35 accuracy level is B.
l0
105
l1
d
d d
L
L L
WZC-010
l0
-
WZP and WZC series thermo resistance components
Ceramic platinum resistance components
077JINGPU
R Jingpu
Model
WZP-012WZP-013WZP-014WZP2-014WZP-015WZP-016WZP2-016
-200800-50150-200800-200800-50150
0.220.50.55
Measurement range
Heat response time t0.5(s)
WZP-017WZP2-017WZP-018WZP-019
-200600-200600-200600-200600-200600-200800
0.80.80.50.50.20.5
WZP-020WZP2-020WZP-203WZP-205
-200800-200800-50150-50150
0.50.555
Ceramic
Ceramic Ceramic
Ceramic Ceramic Ceramic
Material of sleeve
1Cr18Ni9Ti
1Cr18Ni9Ti
1Cr18Ni9Ti1Cr18Ni9Ti
Ceramic Ceramic Ceramic Ceramic Ceramic
Level A/BLevel B
Level A/BLevel A/B
Level B
Accuracy level
Level A/B
Level A/BLevel A/B
Level A/B
Level A/BLevel A/BLevel A/BLevel A/B
Level BLevel B
Pt100Pt100Pt100Pt100Pt100
Graduating number
Pt100Pt100Pt100Pt100Pt100Pt100Pt100Pt100Pt100Pt100
WZP-013
200 32
3
200 3525
M6
3
WZP-203
200 3525
M8
5
WZP-205
WZP-015
200 32
5
WZP-012
2015
1.6
WZP-014
2215
3.2
WZP2-016WZP-016
3015
4.6
WZP2-017WZP-017
3015
2.8
WZP-019
2215
3
WZP2-020WZP-020
3215
3
WZP-018
1215
1.6
-
End platinum resistance components
078JINGPU
R Jingpu
Model
WZPM-0110WZPM-2012
-50150-50150
510
Measurement range
Heat response time t0.5(s)
Material of sleeve
1Cr18Ni9Ti1Cr18Ni9Ti
levelBlevelB
Accuracy level
Pt100Pt100
Graduating number
Note: can be used as changeable components of assembly platinum resistance.
Platinum resistance components with ceramic connection boardModel
WZP-106
WZP2-106
-200500
-200500
Measurement range
15
15
2252503003504004505506509001150
eat response time t0.5(s)
Length L(mm)
Structure
Temperature measurement portion:sheathed temperature sensitive bodyCold end: ceramic connection board riveted and with vibration damper flexible unit
A/B
A/B
Accuracy level
Pt100
Pt100
Graduating number
WZPM-2012
200 10
M121.5
Single wiring diagram
6
L0=L+20
Dual wiring diagram
6
L0=L+20
WZPM-0110
8200
10
WZP-106
A C B D
WZP2-106
R1 R2
1 2 3 4 5 6
For safety reason, please select the products with proper model, if the type-chosing or usage of the products is improper, property loss or body damage may be caused. Designers and users of the system shall take the responsibility to select proper products and use the products according to correct methods.
Safety Warning
Shanghai Jingpu Mechanical & Electrical Technology Co., Ltd.Shanghai Jingpu Instrument Factory
Http: //www.jingpu.com
Tel:021-56618282Fax:021-56618080
E-mail: [email protected]
WZP and WZC series thermo resistance components
- 75.pdf- 76.pdf- 77.pdf- 78.pdf