Transcript of Www.GasBadge.com. What is the It is the Next Generation, Calibration Station for the GasBadge ®...
www.GasBadge.com
What is the
www.GasBadge.com
It is the Next Generation, Calibration Station for the GasBadge®
Plus Personal Monitor
www.GasBadge.com
Optional PrinterLCD Display
Instrument Bay
Bump TestButton
CalibrateButton
www.GasBadge.com
Physical Specifications
• Desktop unit• Can mount directly on a wall • Universal power input• Fresh air port• One gas inlet port • Serial printer interface• USB interface for PC• Dual push-buttons
www.GasBadge.com
Fresh Air Gas inlet
Functionality
• Automatic bump tests• Automatic calibration• Automatic report generation• USB interface for connection to PC• Download event logger• Stores last 200 reports (non-
volatile memory)• External serial printer interface• Optional built-in printer• Supports GasBadge Plus
www.GasBadge.com
Bump Test
• Push button activated• Measures sensor response• 50% response = pass (toxic)
– 19.6% for O2• Bump test report printed
automatically– To serial port / printer– To internal printer– Can be downloaded to PC
www.GasBadge.com
Bump Test Report
Prints automatically if external printeris connected, or if internal printer is installed
www.GasBadge.com
Industrial Scientific Corp.Cal Plus v1.0.025 Dec 04 Time: 14:45Gas Badge (or Gas Badge Pro)Serial Number: 1234567890Software v1.0Hardware v2.0Bay Number 1 (for multiple bay version)Bump Test: PASSSensor: COGas Reading: 61 ppmCal Gas Conc.: 100 ppmHigh Alarm: 70 ppmLow Alarm: 35 ppmCylinder Lot No.:_____________________________Technician Initials:_____________________________________________________________________
Calibrations
• Push button activated• Adjusts sensors accuracy• Calibration report printed
automatically– To serial port / printer– To internal printer– Can be downloaded to PC
• Will check to see if instrument was previously calibrated, and question user.
www.GasBadge.com
CalAgain?
Calibration Certificate
Prints automatically if external printeris connected, or if internal printer is installed
www.GasBadge.com
Industrial Scientific Corp.Cal Plus v1.0.025 Dec 04 Time: 14:45Gas Badge (or Gas Badge Pro)Serial Number: 1234567890Software v1.0Hardware v2.0Bay Number 1 (for multiple bay version)Zero: PASSCalibration: PASSSensor: COSpan Reserve: 110 ppmCal Gas Conc.: 100 ppmHigh Alarm: 70 ppmLow Alarm: 35 ppmNext Cal Due: 24 Jan 05Cylinder Lot No.:_____________________________Technician Initials:_____________________________
Display
• Graphic LCD• Displays actions of CalPlus• Backlight • Multiple languages – English, French,
German, and Spanish• LED’s show status (pass/fail)
Ready Zero inProgress
www.GasBadge.com
Modes of operation
• Print Event Log• Print Cal and Bump memory buffer• Clear memory buffer• Select calibration frequency (days)• Set real time clock• Select language• Perform system check
– Checks pump, board, power, printer, solenoid, and EEPROM
www.GasBadge.com
Modes of operation
• Enter by pressing and holding both buttons for 3 seconds
• “Bump” button scrolls through different modes of operation
• “Calibrate” button enters that mode of operation
www.GasBadge.com
Modes of operation
• Print Events– Prints event log from
instrument currently connected– Press “Calibrate” to print– Press “Bump” to go to next
mode– If “Calibrate” is pressed, Cal
Plus checks to ensure this is OK
www.GasBadge.com
PrintingEvents
If the calibrate button is pressed while the ‘Print Events’ screen is displayed, the
‘Print OK’ screen is shown, verifying the users selection to download and print the
saved data from the instrument. If the user presses the bump button, No is
selected and the user is returned to the ‘Print Events’ screen. If the user presses calibrate, Yes is selected and the data is downloaded and sent out the printer port, ‘Printing Events’ is displayed. When the printing is finished, the user is taken to
the ‘Print Buffer’ screen.
PrintEvents
Print OKN Y
Modes of operation
• Print Buffer– Prints entire buffer of reports– Press “Calibrate” to print– Press “Bump” to go to next
mode– If “Calibrate” is pressed, Cal
Plus checks to ensure this is OK
www.GasBadge.com
Printing...
If the calibrate button is pressed while the ‘Print Buffer’ screen is displayed, the
‘Print OK’ screen is shown, verifying the users selection to print every saved bump
and cal report. If the user presses the bump button, No is selected and the user is returned to the ‘Print Buffer’ screen. If
the user presses calibrate, Yes is selected and every saved bump and cal
report are sent out the printer port, Printing’ is displayed. The buffer is NOT erased. When the printing is finished, the user is taken to the ‘Clear Buffer’ screen.
PrintBuffer
Print OKN Y
Modes of operation
• Clear Buffer– Clears entire buffer of reports
• Buffer only clears when forced
• Buffer over-writes when full FIFO (first in first out)
– Press “Calibrate” to clear– Press “Bump” to go to next mode– If “Calibrate” is pressed, Cal Plus
checks to ensure this is OK
www.GasBadge.com
ClearBuffer
Clear OKN Y
If the calibrate button is pressed while the ‘Clear Buffer’ screen is displayed, the
‘Clear OK’ screen is shown, verifying the users selection to clear every saved
bump and cal report. Pressing the bump button will select No and return the user
to the ‘Clear Buffer’ screen. While pressing the calibrate button will select
Yes, and clear the records and then take the user to the ‘Cal Days’ screen.
Modes of operation
• Set Calibration Frequency– Printed on calibration certificates
• Set in days (0-365)• Added to date programmed in
station– Press “Calibrate” to set # of days– Press “Bump” to go to next mode– If “Calibrate” is pressed,
• “Bump” increases value• “Calibrate” accepts value
www.GasBadge.com
Cal Days30
30 ^ OK
If the cal button is pressed while the ‘Cal Days’ screen is displayed, the ’30 Days’ screen is
shown, allowing the user to increase the number of days until the next calibration by
pressing the bump button. The number 30 will increase slowly (by 1 at a time), then faster
while the bump key is continually pressed. The rollover point is set at 365 days, then the counter will start back at 0. Pressing the
calibrate button will save the new number of days (that is displayed) in memory and take the
user to the ‘Set Date’ screen.
Modes of operation
• Set Date / Time– Printed on calibration / bump
certificates • International format dd/mm/yy• 24 hour clock format
– Press “Calibrate” to set date– Press “Bump” to go to next mode– If “Calibrate” is pressed,
• “Bump” increases value• “Calibrate” accepts value
www.GasBadge.com
Set Date
01 Month ^ OK
If the cal button is pressed while the ‘Set Date’ screen is displayed, the ’01 Month’ screen is
shown, allowing the user to increase the month to set the correct date. The month number will
increase by 1 at a time. The rollover point is set at 12 months, then the counter will start back at
1. Pressing the calibrate button will save the new month to the clock, and bring up the ’01 Day’ screen, which will cycle up to 31, then start back at 1. Pressing the calibrate button will save the new day and bring up the ’05
Year’ screen. The year (last 2 digits only) will cycle up to 99 and then start back at 00.
Pressing the calibrate button will save the new year to the clock and bring up the ’12 Hour’
screen. The clock is set using a 24-hour clock, the hours will cycle up to 23, then start back at 00. Pressing the calibrate button will save the
new hour to the clock and bring up the ’00 Min’ screen. This screen will cycle up to 60 and then start back at 00, by pressing the bump button.
Pressing the calibrate button will save the minutes to the clock and return the user to the
‘Select Language’ screen.
01 Day ^ OK
05 Year ^ OK
12 Hour ^ OK
00 Min ^ OK
Modes of operation
• Select Language
– English, Spanish, French and German
• Appears on display
• Prints certificates in this language
– Press “Calibrate” to change language
– Press “Bump” to go to next mode
– If “Calibrate” is pressed,
• “Bump” scrolls to next language
• “Calibrate” accepts language
www.GasBadge.com
SelectLanguage
English^ OK
Espanol^ OK
Francais^ OK
Deutsch^ OK
If the cal button is pressed while the ‘Select Language’ screen is displayed,
the ’English’ screen is shown. This allows the user to select English as the
default language by pressing the calibrate button, and then the user will taken to the ‘Exit’ screen. Pressing the bump button will bring up the ‘Espanol’ selection. While ‘Espanol’ is displayed,
pressing the calibrate will select Spanish as the default language and
take the user to the ‘Exit’ screen. Pressing the bump button will bring up the ‘Francais’ screen, which allows the
user to select French as the default language. By pressing the calibrate
button, French is selected and the user is taken to the ‘Exit’ screen. Pressing
the bump button will bring up the ‘Deutsch’ screen, allowing German to be selected as the default language.
Pressing the bump button will return the user to the ‘Select Language’ screen.
Pressing the calibrate button will select German as the default language and
take the user to the ‘Exit’ screen.
Modes of operation
• System Check
– Tests current draw, pump, solenoids, and printer
– Press “Calibrate” to run system check
– Press “Bump” to go to next mode (Exit)
– If “Calibrate” is pressed, test starts
• If tests fail, error messages displayed
www.GasBadge.com
SystemCheck
RunningCheck...
If the bump button is pressed while the ‘System Check’ screen is displayed, the user is taken to the ‘Exit’ screen. If the cal button is pressed while the ‘System
Check’ screen is displayed, the calibrator starts a check of all the
systems. Any errors will be reported as shown in figures 2 and 3, when the
check is finished. These errors will be displayed for 30 seconds, then the calibrator will return to the ‘System
Check’ screen. Once the user exits the setup mode, the errors will be visible
again on the display.
Modes of operation
• Exit– Press “Calibrate” to exit– Press “Bump” to go to next mode
(Print Buffer)
www.GasBadge.com
Exit
Ready
If the bump button is pressed while the ‘Exit’ screen is displayed, the user is
taken back to the ‘Print Events’ screen. If the cal button is pressed while the ‘Exit’ screen is displayed, the set up mode is exited and the calibration
station is returned to normal operation. If there is no instrument installed, the
station will display ‘Ready’. If there is an instrument installed, and it has been
through a calibration or bump test, the result will be displayed, i.e. ‘Cal Pass’.
Modes of Operation
PrintBuffer
ClearBuffer
Cal Days30
SetDate
SelectLanguage
Exit
PrintEvents
SystemCheck
www.GasBadge.com
First Mode
“Bump” button selects mode“Calibrate” button enters mode
PC interface
• Connects to PC via USB• View and save:
– Bump reports– Calibration reports
• Download event log from instrument• Downloads calibration and bump
reports• Setup instrument
www.GasBadge.com
www.GasBadge.com
www.GasBadge.com
Sample Calibration Certificate
www.GasBadge.com
Sample Bump Test Certificate
Sample Event log
Accessory Items
• Calibration gas• Calibration gas cylinder holder (wall
mount)• Internal printer• External serial data printer (120
VAC)• External battery powered printer
(battery only)
www.GasBadge.com
Pricing
• Non-printer version: $795.00 USD• Printer version: $1095.00 USD
www.GasBadge.com
Availability
• Taking orders September 1, 2005