WRVR Troubleshooting Guide

download WRVR Troubleshooting Guide

of 3

Transcript of WRVR Troubleshooting Guide

  • 7/31/2019 WRVR Troubleshooting Guide

    1/3

    WRVR Troubleshooting Guide

    Problems Possible causes ActionsATC reported no

    display on screen/

    black screen

    1. Monitor on power savingmode/screensaver

    2. Monitor turned off3. CPU turned off4. No power to monitor5. No power to CPU6. Monitor faulty7. CPU faulty

    1. Move PC mouse orpress any keys on

    keyboard

    2. Turn on the Monitor3. Turn on the CPU4. Turn on power supply5. Make sure power cable

    connected properly

    6. Try to change monitorto test

    7. Inform MET KLIA theATC CPU/Monitor isfaulty

    ATC operator

    reported cannot

    access

    METairport/WRVR

    display/Public

    IP/192.168.101.50

    1. IP address entered in thenavigation bar is incorrect

    2. Internet is down (for CivilAirport)

    3. Network cable is not connectedproperly to the CPU network

    port or to the Network

    Switch/Router

    4. Network cable is damaged5. Network Switch is turned off6. Access Point cable does not

    connected properly to the

    Network Switch (Military Airport)

    7. Access Point adapter is turnedoff (Military Airport)

    8. Access Point adapter is faulty(Military Airport)

    9. Access Point adapter cable is notproperly connected to the Access

    Point (Military Airport)10.Access Point cable is damaged

    (Military Airport)

    11.Access Point is not in the line ofsight with the Subscriber Module

    (Military Airport)

    12.Access Point is damaged13.Subscriber Module adapter is

    turned off (Military Airport)

    14.Subscriber Module adapter isfaulty (Military Airport)

    15.Subscriber Module adapter cableis not properly connected to the

    1. Provide the ATC withthe correct IP Address

    2. Ask them to checkother website

    (email/google/yahoo).

    If cannot access then

    ask them to call the

    tower internet service

    provider.3. Make sure the network

    port light is blinking to

    confirm the cable is

    connected properly

    4. Change network cable5. Turn on the network

    switch

    6. Refer to #37. Turn on the adapter8. Replace the adapter9. Make sure the adaptercable is inserted

    properly

    10.Refer to #411.Realign the Access

    Point or the Subscriber

    Module and do a ping

    test until connection is

    established

    12.Replace the AccessPoint

    13.Refer to #7

    14.Refer to #8

  • 7/31/2019 WRVR Troubleshooting Guide

    2/3

    Subscriber Module (Military

    Airport)

    16.Subscriber Module cable isdamaged (Military Airport)

    17.Subscriber Module is damaged18.MET Station network switch isturned off19.Network cable from DPU is not

    connected properly to the MET

    Station Network Switch or to

    DPU

    20.Network cable from DPU to METStation Network Switch is

    damaged

    21.DPU is turned off22.DPU power cable is not

    connected properly23.UPS is turned off24.UPS power cable is not

    connected properly

    25.UPS is faulty26. Internet is down (Civil airport)27.DPU network cable for internet

    connection is not connected

    properly to the MET Station

    router/LAN Network Switch

    28.MET Station Router/LANNetwork Switch is faulty29.WRVR system software ishanged/crashed

    30.DPU is damaged31.New DPU is not working/not

    available/damaged

    32.Unknown causes

    15.Refer to #916.Refer to #417.Replace the Subscriber

    Module

    18.Refer to #519.Refer to #320.Refer to #421.Turn on the DPU22.Connect the power

    cable properly

    23.Turn on the UPS24.Connect the UPS cable

    properly

    25.Bypass the UPS orreplace the UPS

    26.Report to MET KLIA orMMD ICT

    27.Refer to #328.Refer to #2629.Restart the system30.Turn on the other DPU

    and do proper cable

    swap

    31.Report to MET KLIA32.Refer to #31

    ATC operator

    reported no data/red

    slashes on screen

    1. Screen is hanged2. Network cable between DPU and

    Network Switch is down

    3. Network between Networkswitch and Access Point is down4. Network between Access Pointand Subscriber Module is down

    5. Network between SubscriberModule and AE Network Switch

    is down

    6. Network between AE NetworkSwitch and AQ/Arm Processor is

    down

    7. AQ is down8. AQ is hanged9.

    Power connection between AQand Surge protector is

  • 7/31/2019 WRVR Troubleshooting Guide

    3/3

    down/insufficient

    10.Power connection betweenSurge protector and MCB 5V is

    down/insufficient

    11.Power connection between MCB5V and 5V Power Supply isdown/insufficient

    12.Power connection between 5VPower Supply and 240VAC MCB

    is down

    13.AQ shows data is 014.Data connection between AQ

    and Surge Protector is down

    15.Data connection between SurgeProtector and AE Connector is

    down

    16.Data connection betweenconnector and Surge ProtectorBox is down

    17.Data connection between SurgeProtector Box and Sensor is

    down

    18.Power connection betweensensor and Surge Protector Box

    is down/insufficient

    19.Power connection betweenSurge Protector Box and

    connector is down/insufficient20.Power connection betweenconnector and sensors MCB is

    down/insufficient

    21.Power connection betweenconnector and MCB 12V is

    down/insufficient

    22.Power connection between MCB12V and 12V power supply is

    down/insufficient

    23.Power connection between 12VPower Supply and 240 VAC MCBis down

    24.Power connection between240VAC and Main Source is

    down