SPLIT-TYPE AIR CONDITIONERS Full Product Line Catalogue 2 0 15 NOTICE Do not install indoor units in areas (e.g., mobile phone base stations) where the emission of VOCs such as phthalate compounds and formaldehyde is known to be high as this may result in a chemical reaction. When installing or relocating or servicing the air conditioners, use only the specified refrigerant (R410A) to charge the refrigerant lines. Do not mix it with any other refrigerant and do not allow air to remain in the lines. If air is mixed with the refrigerant, then it can be the cause of abnormal high pressure in the refrigerant lines, and may result in an explosion and other hazards. The use of any refrigerant other than that specified for the system will cause mechanical failure, system malfunction or unit breakdown. In the worst case, this could lead to a serious impediment to securing product safety. Eco Changes is the Mitsubishi Electric Group’s environmental statement, and expresses the Group’s stance on environmental management. Through a wide range of businesses, we are helping contribute to the realization of a sustainable society. Wrap Yourself in Comfort and Quiet Eco-conscious Technologies from Japan Full Product Line Catalogue 2015

Transcript of Wrap Yourself in Comfort and Quiet - Mitsubishi Electric VN · MXY SERIES (Cooling Only) MXZ SERIES...

Page 1: Wrap Yourself in Comfort and Quiet - Mitsubishi Electric VN · MXY SERIES (Cooling Only) MXZ SERIES (Heat Pump) EXTERNAL DIMEMSIONS PIPING INSTALLATIONS CITY MULTI CITY MULTI S SERIES

SPLIT-TYPE AIR CO

ND

ITION

ERS Full Product Line Catalogue 2015

NOTICE� Do not install indoor units in areas (e.g., mobile phone base stations) where the emission of VOCs such as phthalate

compounds and formaldehyde is known to be high as this may result in a chemical reaction. � When installing or relocating or servicing the air conditioners, use only the specified refrigerant (R410A) to charge the

refrigerant lines.Do not mix it with any other refrigerant and do not allow air to remain in the lines.If air is mixed with the refrigerant, then it can be the cause of abnormal high pressure in the refrigerant lines, and may result in an explosion and other hazards.The use of any refrigerant other than that specified for the system will cause mechanical failure, system malfunction or unit breakdown. In the worst case, this could lead to a serious impediment to securing product safety.

Eco Changes is the Mitsubishi Electric Group’s environmental statement,and expresses the Group’s stance on environmental management. Through a wide range of businesses, we are helping contribute to the realization of a sustainable society.

Wrap Yourself in Comfort and QuietEco-conscious Technologies from Japan

Full Product Line Catalogue

2015

Page 2: Wrap Yourself in Comfort and Quiet - Mitsubishi Electric VN · MXY SERIES (Cooling Only) MXZ SERIES (Heat Pump) EXTERNAL DIMEMSIONS PIPING INSTALLATIONS CITY MULTI CITY MULTI S SERIES

Economical Operation

We are able to offer industry-leading levels of energy-efficient operation for both heating and cooling with the latest innova-tive inverter technologies. Save energy and money with the Mitsubishi Electric Inverter Multi split System.

Comfort with less noise, based on smooth operation and innovative features such as automatic selection of low-noise mode when operation load is low. Choose a wall-mounted model to create a silent and comfortable space where noise levels are kept low so that soothing peace and quiet can be enjoyed.

Offering the ability to select up to 6 indoor units for a single outdoor unit, Mitsubishi Electric Inverter Multi split Systems satisfy diversified needs. With the cooling capacities of outdoor units ranging from 5.0 to 12.0kW and a line up of different models to suit specific applications, you will not be hard pressed to find a better match for your building dimen-sions and comfort requirements.

Silent Control Flexible Choice

For luxury mansion and condominium,Maximize the comfortability with a single outdoor unit,Mitsubishi Electric Inverter Multi split Systems

Space Savings

The Mitsubishi Electric Inverter Multi split System is designed to allow several indoor units to be connected to a singleoutdoor unit. This enhances exterior aesthetics by reducing the number of outdoor units necessary, while also providing you with an easy and economical way of adding indoor units at any time.

1 2

Page 3: Wrap Yourself in Comfort and Quiet - Mitsubishi Electric VN · MXY SERIES (Cooling Only) MXZ SERIES (Heat Pump) EXTERNAL DIMEMSIONS PIPING INSTALLATIONS CITY MULTI CITY MULTI S SERIES

INVERTER MULTI SPLITLINE-UP

INVERTER TECHNOLOGIES

FUNCTIONS

MXY SERIES (Cooling Only)

MXZ SERIES (Heat Pump)

EXTERNAL DIMEMSIONS

PIPING INSTALLATIONS

CITY MULTICITY MULTI S SERIES

INDOOR UNIT LINE-UP

SYSTEM CONTROL

6

7- 8

9-14

15-24

25-33

34-39

40-41

43-46

47-48

49-50

TABLE OF CONTENTS

Types of Air Conditioning Systems and Suitable Choice for Your HomeEnhance room comfort with the air conditioner that best matches the interior.For reliable operation and design, Mitsubishi Electric is the logical choice.

· Small residences like studio apartments· Homes with floor area of 20-50m2

· Installing additional units if required

Single Split

· Small to medium-sized residences (condominiums or leased apartments)· Homes with floor area of 50-100m2 · Homes with limited space for outdoor unit installation· Increasing usable space at homes (for developers)· Users who prefer to keep neat appearance with ceiling-concealed

model· Wide variety of indoor unit combination

Inverter Multi Split (5.0~12.0kW)

· Large-scale residences (condominiums or leased apartments)· Homes with floor area of 80m2 or more· Entrance hall or penthouse· Using a centralized control system as integrated control of air condi-

tioning, lighting, security system and other electric appliances· More freedom in air conditioning design due to less piping length restrictions· Increasing usable space in homes (for developers)· Users who prefer to keep neat appearance with ceiling-concealed

model· Wide variety of indoor unit combination

CITY MULTI (12.5~25.0kW)

� Suitable for

� Suitable for � Suitable for

Please refer to page 50 for centralized control.

3 4

Page 4: Wrap Yourself in Comfort and Quiet - Mitsubishi Electric VN · MXY SERIES (Cooling Only) MXZ SERIES (Heat Pump) EXTERNAL DIMEMSIONS PIPING INSTALLATIONS CITY MULTI CITY MULTI S SERIES

SERIES

INVERTER MULTI SPLIT

LINE-UP

Indoor Unit for MXY and MXZ

MSY-E SeriesMSZ-E Series

Wall-mounted

1-way cassette

4-way cassette

Celling-concealed

MSY-G SeriesMSZ-G Series

MLZ Series

SEZ Series

PLA Series

INVERTER Models (Heat Pump)

MXZ SERIES

Up to 2 indoor unitsMXY-2E20VA

INVERTER Models (Cooling Only)

MXY SERIES7.5kW 7.5kW 9.2kWCapacity Class

Model Name

Up to 4 indoor unitsMXY-4A28VA

Up to 4 indoor unitsMXY-4A38VA

Up to 3 indoor unitsMXY-3A28VA

5.0kW

3.5kW 5.0kW 6.0kWCapacity ClassModel Name 2.5kW 7.1kW

Up to 2 indoor unitsMXZ-2C52VA

6.8kW 7.1kW 8.0kWCapacity Class

Model Name

Up to 4 indoor unitsMXZ-4C71VA

Up to 4 indoor unitsMXZ-4C80VA

10.0kW

Up to 5 indoor unitsMXZ-5C100VA

12.0kW

Up to 6 indoor unitsMXZ-6C120VA

Up to 3 indoor unitsMXZ-3C68VA

5.2kW

5 6

Page 5: Wrap Yourself in Comfort and Quiet - Mitsubishi Electric VN · MXY SERIES (Cooling Only) MXZ SERIES (Heat Pump) EXTERNAL DIMEMSIONS PIPING INSTALLATIONS CITY MULTI CITY MULTI S SERIES

Magnetic torque+

Reluctance torque

INVERTER TECHNOLOGIESMitsubishi Electric inverters ensure superior performance including the optimum control of operation frequency. As a result, optimum power is applied in all heating/cooling ranges and maximum comfort is achieved while consuming minimal energy. Fast, comfortable operation and low running cost — That’s the Mitsubishi Electric promise.

Inverters electronically control the electrical voltage, current and frequency of electrical devices such as the compressor motor in an air conditioner. They receive information from sensors monitoring operating conditions, and adjust the revolution speed of the compressor, which directly regulates air conditioner output. Optimum control of operation frequency results in eliminating the consumption of excessive electricity and providing the most comfortable room environment.

Quick & Powerful

Increasing the compressor motor speed by controlling the operation frequency ensures powerful output at start-up, brings the room temperature to the comfort zone faster than units not equipped with an inverter. Hot rooms are cooled, and cold rooms are heated faster and more efficiently.

Room Temperature Maintained

The compressor motor operating frequency and the change of room temperature are monitored to calculate the most efficient waveform to maintain the room temperature in the comfort zone. This elimi-nates the large temperature swings common to non-inverter sys-tems, and guarantees a pleasant, comfortable environment.

MORE ADVANTAGES WITH MITSUBISHI ELECTRIC

INVERTERS – HOW THEY WORK

Impressively low operating cost is a key advantage of inverter air conditioners. We’ve combined advanced inverter technologies with cutting-edge electronics and mechanical technologies to achieve a synergistic effect that enables improvements in heating/cooling performance efficiency. Better performance and lower energy consumption are the result.

ECONOMIC OPERATION

Simple comparison of air conditioner operation control with and without inverter

TRUE COMFORT

� Inverter Operation Image (cooling mode)

Grooved Piping

High-performance grooved piping is used in heat exchangers to in-crease the heat exchange area.

Reluctance DC Rotary Compressor

Powerful neodymium magnets are used in the rotor of the reluc-tance DC compressor motor. More efficient operation is realised by strong magnetic and reluctance torques produced by the magnets.

DC compressor motor (rotor)

Neodymiummagnets

Rare Earth Magnet Rotor (Compressor)

An innovative motor with a rare earth magnet rotor is equipped in the compressor to ensure excellent efficiency. The rare earth magnet has a residual magnetic flux density threefold that of the previously used ferrite magnet.

Rare earth magnet (for MSZ-EF)

DC Fan Motor

A highly efficient DC motor drives the fan of the outdoor unit. Efficiency is much higher than an equivalent AC motor.

Joint Lap DC Motor

Mitsubishi Electric has developed a unique motor, called the “Poki-Poki Motor” in Japan, which is manufactured using a joint lapping technique. This innovative motor operates based on a high-density, high-magnetic force, leading to extremely high effi-ciency and reliability.

Grooved piping

Cross-sectional viewPipe image

PAM

Conventionalinverter

Without PAM control

� Merits of PAM Control

With PAM control

Supplyvoltage

CurrentTime

Time

PAM adjusts the form of the current wave so that it becomes close to that of the supply voltage wave. High harmonics are reduced and 98% of the electricity is utilized.

PAM is a technology that controls the current waveform so that it resembles the supply voltage wave, thereby reducing loss and real-ising more efficient use of electricity. Using PAM control, 98% of the input power supply is used effectively.

PAM (Pulse Amplitude Modulation)

Power increasedEfficient voltage increase realises increased power

Significant energy savingsRemarkable reduction in power loss saves electricity

Limited powerInsufficient power when needed

Limited energy savingsElectricity is wasted

LEV1

Power receiver

Heat exchanger

Heatexchanger

Compressor

LEV2

Power Receiver and Twin LEV Control

Mitsubishi Electric has developed a power receiver and twin linear expansion valves (LEVs) circuit that optimise compressor perfor-mance. This technology ensures optimum control in response to op-erating waveform and outdoor temperature. Operating efficiency has been enhanced by tailoring the system to the characteristics of R410A refrigerant.

Temperature (°C) Cooling capacity (W)

Operation time (min)

Rated capacity

Setting temperatureIndoor temperature

Measured capacity

Point 1

Point 1

When room temperature is higher than the setting, capacity rises quickly, adjusting the temperature to the original setting.

When room temperature reaches the desired setting, capacity eases in order to maintain the set temperature level.

Point 2

Point 2

7 8

Page 6: Wrap Yourself in Comfort and Quiet - Mitsubishi Electric VN · MXY SERIES (Cooling Only) MXZ SERIES (Heat Pump) EXTERNAL DIMEMSIONS PIPING INSTALLATIONS CITY MULTI CITY MULTI S SERIES

M-NET InterfaceInterface to connect with M-NET con-trollers.

M-NET interface

Details

Major Optional Parts Required

• Group of air conditioners can be controlled by MELANS system controller (M-NET).

• MAC-399IF-E (M-NET Interface)• MELANS System controller• PAC-SC50KUA (power supply unit)

• PAC-SF81MA-E (M-NET converter)• MELANS System controller• PAC-SC50KUA (power supply unit)

Outdoor unit

Indoor unit

MAC-399IF-E

ME remote controller (PAR-F27MEA)

PAC-SC50KAPower supplyunit

City Multi indoor unit

M-NET ConnectionsPAR-30MAAPAR-21MAA

Outdoorunit

Indoor unit

MAC-399IF-EMELANSsystem controller(AG-150A etc)

MELANSsystem controller(AG-150A etc)

PAC-SC50KAPower supplyunit

City Multi indoor unit

PAR-30MAAPAR-21MAA

Outdoorunit

Indoor unit

M-NET adapterPAC-SF81MA-EMELANS

system controller(AG-150A etc)

PAC-SC50KUAPower supplykit

PAR-30MAAPAR-21MAA

PAR-30MAAPAR-21MAA

Indoor unitIndoor unit

Details

Major Optional Parts Required

SYSTEM CONTROLFUNCTIONS (1)Versatile system controls can be realised using optional parts, relay circuits, control panels, etc.

OTHERS

2-remote Controller Control

With two remote controllers, control can be performed locally and remotely from two locations.

Operation Control by Level Signal

Air conditioner can be started/stopped remotely. In addition, On/Off operation by local remote controller can be prohibited/permitted.

Operation Control by Pulse Signal

Remote Display of Operating Status

Operating status can be displayed at a remote location.

Allows On/Off operation with timer*For control by an external

timer, refer to B Operation Control by Level Signal.

Timer Operation

PAR-30MAAPAR-21MAA PAR-30MAA

PAR-21MAA

(Example of 1 : 1 system)

(Example of 1 : 1 system)

Relay box (to be purchased) locally)

Relay box (to be purchased) locally)

Adapter for remote On/Off

Adapter for remote On/Off

PAR-SL97A-E

PAR-SL97A-E

(Example of 1 : 1 system)

PAR-30MAA

(Example of 1 : 1 system x 2)

Relay box (to be purchased locally)

(Example of 1 : 1 system x 2)

* Set "Main" and "Sub" remote controllers. * When using wired and

wireless remote controllers

PAR-SL97A-E

(Example of Simultaneous Twin)

(Example of Simultaneous Twin)

• Wired Remote ControllerPAR-30MAAPAR-21MAA(for PKA, PAC-SH29TC-E is required)

• Wireless Remote ControllerPAR-SL97A-E (Except for SLZ)

• Wireless Remote Controller Kit for PCAPAR-SL99B-E

• Adapter for remote On/Off PAC-SE55RA-E

• Relay box (to be purchased locally)• Remote control panel (to be purchased

locally)

Standard functions of PAR-30MAA

A

B

C

D

E

Details Major Optional Parts RequiredSystem Examples

Wired remote controller Wireless remote controller

Remote display panel

Remote display panelPAR-30/

21MAA

Remote control panel

Remote control panelWired remote

controller

• Up to two remote controllers can be connected to one group.

• Both wired and wireless remote controllers can be used in combination.

• Operation other than On/Off (e.g., adjust-ment of temperature, fan speed, and airflow) can be performed even when remote controller operation is prohibited.

• Timer control is possible with an external timer.

Connector cable for remote display

Connector cable for remote display

PAR-SL97A-E

(Example of 1 : 1 system x 2)

Relay box (to be purchased locally)

(Example of 1 : 1 system x 2)

• Connector cable for remote display PAC-SA88HA-E /PAC-725AD(10 pcs. x PAC-SA88HA-E)

• Relay box (to be purchased locally)• Remote control panel (to be purchased

locally)Remote control panel

Remote control panelWired remote

controller

• The pulse signal can be turned On/Off.• Operation/emergency signal can be

received at a remote location.

• Operation/emergency signal can be received at a remote location (when channeled through the PAC-SF40RMno-voltage signal, when channeled through the PAC-SA88HA-E DC 12V signal).

• Weekly Timer:On/Off and up to 8 pattern temperatures can be set for each calendar day. (Initial setting)

• On/Off Timer:On/Off can be set once each within 72 hr in intervals of 5-minute units.

• Auto-off Timer:Operation will be switched off after a certain time elapse. Set time can be changed from30 min. to 4 hr. at 10 min. intervals. *Simple Timer and Auto-off Timer cannot be used at the same time.

• Remote display panel (to be purchased locally)

• Connector cable for remote display PAC-SA88HA-E / PAC-725AD(10 pcs. x PAC-SA88HA-E)

• Relay box (to be purchased locally)• Remote operation adapter PAC-SF40RM *Unable to use with wireless remote controller

Remote operation adapter/Connector cable for remote display + Relay box

Remote operation adapter/Connector cable for remote display + Relay box

For P Series and S Series Indoor Units

For M Series Indoor Units (New A-control Models Only)

1

2

Remote On/Off Operation

Remote Display of Operation Status

Control Details Major Optional Parts RequiredSystem Examples Connection Details

• MAC-397IF (Interface)• Parts for circuit such as relay

box, lead wire, etc. (to be purchased locally)

• MAC-397IF-E (Interface)• Parts for circuit to be

purchased locally (DC power source needed)

Connect the interface to the air conditioner. Then connect the locally purchased remote controller to the terminal in the interface.

Connect the interface to the air conditioner. Then connect the locally purchased remote controller to the terminal in the interface.

On/Off operation is possible from a remote location.

The operation status (On/Off) or error signals can be monitored from a remote location.

Outdoor unit

Indoor unit

MAC-397IF-E

Remote control section (to be purchased locally)

Switch

Outdoor unit

Indoor unit

MAC-397IF-E

Remote monitor section (to be purchased locally)

Power supply

Resistance LED

• Air conditioner can be started/stopped remotely.( 1 and 2 can be used in combination)

• The On/Off status of air conditioners can be confirmed remotely.( 1 and 2 can be used in combination)

Major Optional Parts

System Control InterfaceInterface to connect with M-NET controllers.

MAJOR SYSTEM CONTROL

M series Indoor Unit

MXZ Series Outdoor

Indoor Unit

Outdoor Unit

S series & P series Indoor Unit

System Examples

MXZ Series Outdoor

Details

Major Optional Parts Required

• One remote controller can control plural air conditioners with the same settings simultaneously.• One remote controller can control up to 16 refrigerant systems. (When connected to a MXZ unit, MAC-397IF-E is counted as one system.)• Up to two remote controller can be connected.

• MAC-397IF-E (Interface)• PAR-30MAA (Wired remote controller)• PAR-21MAA (Wired remote controller)

PAR-30MAA ControlPAR-21MAA Control

System Group ControlPAR-30MAAPAR-21MAA

MAC-397IF-E

Indoor unit

Outdoor unit

Indoor unit

Outdoor unit

Outdoor unit

Indoor unit

MAC397IF-E

PAR-30MAAPAR-21MAA

PAR-30MAAPAR-21MAA

PAR-30MAAPAR-21MAA

MAC-397IF-E

• Wired remote controller can be connected toindoor unit

• MAC-397IF-E (Interface)• PAR-30MAA (Wired remote controller)• PAR-21MAA (Wired remote controller)

• PAR-30MAA (Wired remote controller)• PAR-21MAA (Wired remote controller)

Standard equipment (for indoor units compatible with wired remote controllers)

MAJOR OPTIONAL PARTS

M-NET Converter

Used to connect P Series A-control models to M-NET controllers. M-NET

Converter

Econo Cool Energy-Saving Feature

“Econo Cool” is an intelligent temperature control feature that adjusts the amount of air directed towards the body based on the air-outlet temperature. The setting temperature can be raised by as much as 2°C without any loss in comfort, thereby realising a 20% gain in energy efficiency. (Function only available during manual cooling operation.)

Pure White

Pure white is adopted for the unit colour; white expressing the essence of cleanliness and easily matching virtually all interior décor.

Auto Vane

The vane closes automatically when the air conditioner is not running, concealing the air outlet and creating a flat surface that is aesthetically appealing.

Econo Cool ModeA comfortable room environment is maintained even when setting the temperature 2°C higher than the conventional cooling mode.

Conventional Econo CoolAmbient temperature 35°C 35°C

Set temperature 25°C 27°C

30°C 29.3°C

Econo Cool on Conventional cooling mode

14 16 18 20 22 24 26 28

Perceived temperature Temperature distribution (°C)

ENERGY-SAVING

AIR QUALITY

ATTRACTIVE

This high-performance filter has a much finer mesh compared to stan-dard filters, and is capable of capturing minute particulates floating in the air that were not previously caught.

High-efficiency Filter

Catechin is a bioflavonoid by-product of green tea with both antiviral and antioxidant qualities. It also has an excellent deodorising effect, which is why Mitsubishi Electric uses the compound in its air condi-tioner filters. In addition to improving air quality, it prevents the spreading of bacteria and viruses throughout the room. Easily re-moved for cleaning and maintenance, when the filter is washed regu-larly the deodorising action is rated to last more than 10 years.

Catechin Filter

Indoor air quality is enhanced by the direct intake of fresh exterior air.

Fresh-air Intake

The anti-allergy enzyme filter works to trap allergens such as molds and bacteria and decompose them using enzymes retained in the filter.

Anti-allergy Enzyme Filter

A special process for the entrapment surface improves the filtering effect, making the maintenance cycle longer than that of units equipped with conventional filters.

Long-life Filter

Air conditioner operating time is monitored, and the user is notified when filter maintenance is necessary.

Filter Check Signal

This function features both the Air Cleaning Filter and Anti-allergy Enzyme Filter.

Electrostatic Anti-allergy Enzyme Filter

The filter has a large capture area and incorporates nanometre-sized platinum-ceramic particles that work to eliminate bacteria and deo-dourise the circulating air.

Nano Platinum Filter

ElectrostaticAnti-allergy

NanoPlatinum

Air Discharge GuideChanges the direction of air being exhausted from the outdoor unit.

Wide and Long Airflow

The wide and long airflow function is especially beneficial for large spaces, helping to ensure that air is well circulated and reaches every corner of the room.

AIR DISTRIBUTION

The air outlet vane swings up and down so that the airflow is spread evenly throughout the room.

Horizontal Vane

The air outlet fin swings from side to side so that the airflow reaches every part of the room.

Vertical Vane

In the case of rooms with high ceilings, the outlet-air volume can be increased to ensure that air is circulated all the way to the floor.

High Ceiling Mode

If the room has a low ceiling, the airflow volume can be reduced for less draft.

Low Ceiling Mode

The airflow speed mode adjusts the fan speed of the indoor unit automatically according to the present room conditions.

Auto Fan Speed Mode

“i save” Mode/Smart Set

“i save” is a simplified setting function that recalls the preferred (preset) temperature by pressing a single button on the remote controller. Smart Set : Press the same button twice in repetition to immediately return to the previous temperature setting. Using this function contributes to comfortable waste-free operation, realising the most suitable air conditioning settings and saving on power consumption when, for example, leaving the room or going to bed.

Auto Restart

Especially useful at the time of power outages, the unit turns back on automatically when power is restored.

On/Off Operation Timer

Use the remote controller to set the times of turning the air conditioner On/Off.

Operation Lock

To accommodate specific use applications, cooling or heating operation can be specified when setting the control board of the outdoor unit. A convenient option when a system needs to be configured for exclusive cooling or heating service.

CONVENIENCE

Ampere Limit Adjustment

Dipswitch settings can be used to adjust the maximum electrical current for operation. This function is highly recommended for managing energy costs.

*Maximum capacity is lowered with the use of this function.

Low-noise Operation (Outdoor Unit)

System operation can be adjusted to prioritise less noise from the outdoor unit over air conditioning performance.

Low-temperature Cooling

Intelligent fan speed control in the outdoor unit ensures optimum performance even when the outside temperature is low.

Auto Changeover

The air conditioner automatically switches between heating and cool-ing modes to maintain the desired temperature.

9 10

Page 7: Wrap Yourself in Comfort and Quiet - Mitsubishi Electric VN · MXY SERIES (Cooling Only) MXZ SERIES (Heat Pump) EXTERNAL DIMEMSIONS PIPING INSTALLATIONS CITY MULTI CITY MULTI S SERIES

M-NET InterfaceInterface to connect with M-NET con-trollers.

M-NET interface

Details

Major Optional Parts Required

• Group of air conditioners can be controlled by MELANS system controller (M-NET).

• MAC-399IF-E (M-NET Interface)• MELANS System controller• PAC-SC50KUA (power supply unit)

• PAC-SF81MA-E (M-NET converter)• MELANS System controller• PAC-SC50KUA (power supply unit)

Outdoor unit

Indoor unit

MAC-399IF-E

ME remote controller (PAR-F27MEA)

PAC-SC50KAPower supplyunit

City Multi indoor unit

M-NET ConnectionsPAR-30MAAPAR-21MAA

Outdoorunit

Indoor unit

MAC-399IF-EMELANSsystem controller(AG-150A etc)

MELANSsystem controller(AG-150A etc)

PAC-SC50KAPower supplyunit

City Multi indoor unit

PAR-30MAAPAR-21MAA

Outdoorunit

Indoor unit

M-NET adapterPAC-SF81MA-EMELANS

system controller(AG-150A etc)

PAC-SC50KUAPower supplykit

PAR-30MAAPAR-21MAA

PAR-30MAAPAR-21MAA

Indoor unitIndoor unit

Details

Major Optional Parts Required

SYSTEM CONTROLFUNCTIONSVersatile system controls can be realised using optional parts, relay circuits, control panels, etc.

MAJOR SYSTEM CONTROL

M series Indoor Unit

MXZ Series Outdoor

Indoor Unit

Outdoor Unit

S series & P series Indoor Unit

System Examples

MXZ Series Outdoor

Details

Major Optional Parts Required

• One remote controller can control plural air conditioners with the same settings simultaneously.• One remote controller can control up to 16 refrigerant systems. (When connected to a MXZ unit, MAC-397IF-E is counted as one system.)• Up to two remote controller can be connected.

• MAC-397IF-E (Interface)• PAR-30MAA (Wired remote controller)• PAR-21MAA (Wired remote controller)

PAR-30MAA ControlPAR-21MAA Control

System Group ControlPAR-30MAAPAR-21MAA

MAC-397IF-E

Indoor unit

Outdoor unit

Indoor unit

Outdoor unit

Outdoor unit

Indoor unit

MAC397IF-E

PAR-30MAAPAR-21MAA

PAR-30MAAPAR-21MAA

PAR-30MAAPAR-21MAA

MAC-397IF-E

• Wired remote controller can be connected toindoor unit

• MAC-397IF-E (Interface)• PAR-30MAA (Wired remote controller)• PAR-21MAA (Wired remote controller)

• PAR-30MAA (Wired remote controller)• PAR-21MAA (Wired remote controller)

Standard equipment (for indoor units compatible with wired remote controllers)

MAJOR OPTIONAL PARTS

Air Discharge GuideChanges the direction of air being exhausted from the outdoor unit.

FUNCTIONS (2)

Pattern Settings: Input up to four settings for each daySettings: •Start/Stop operation •Temperature setting �The operation mode cannot be set.

� Example Operation Pattern (Winter/Heating mode)Mon. Tues. Wed. Thurs. Fri. Sat. Sun.

ON 20°CON 20°C ON 20°C ON 20°C ON 20°C ON 20°C ON 20°CAutomatically changes to high-power operation at wake-up time

Automatically lowers temperature at bedtime for energy-saving operation at night ON 18°CON 18°C ON 18°C ON 18°C ON 18°C ON 18°C ON 18°C

Settings

Built-in Weekly Timer Function

Easily sets desired temperatures and operation start/stop times to match lifestyle patterns. Reduce wasted energy consumption by using the timer to prevent forgetting to turn off the unit and eliminate temperature setting adjustments.

(during sleeping hours)

Automatically turned off during work hoursMidday is warmer, so the temperature is set lower

OFFOFF OFF OFF OFF ON 18°C ON 18°C

Automatically turns on, synchronized with arrival at homeAutomatically raises temperature setting tomatch time when outside-air temperature is low

ON 20°CON 20°C ON 20°C ON 20°C ON 20°C ON 20°C ON 20°C

Cleaning-free Pipe Reuse

The application of pipe reuse technology such as Mitsubishi Electric’s original hard alkyl benzene oil makes it possible to reuse the same piping, thereby allowing cleaning-free renewal of air conditioning systems that use R22 refrigerant.

Wiring/Piping Correction Function*

The push of a single button is all that is required to confirm that piping and wiring are properly connected. Corrections are made au-tomatically if a wiring error is detected, eliminating the need for com-plicated wiring confirmation work when expanding the number of rooms served.* This function cannot be used when the outdoor temperature is below 0°C.

The correction process requires 10–20 minutes, and only works when the unit is set to the Cooling mode.

Drain Pump

A built-in drain pump enables drain piping to be raised.

Flare Connection

Flare connection to cooling pipe work is possible.

Wiringconfirmation

is timeconsuming.

The outdoor unit matches

pipes and wiring.

Easy Clean

The cover panel can be quickly removed for washing and the airflow vents can be opened without any special tools, making it easy to clean the inside of the air conditioner in minutes. Periodic cleaning of the air conditioner is recommended to maintain optimum operating efficiency and energy savings.

MAINTENANCE

Self-Diagnostic Function (Check Code Display)

Check codes are displayed on the remote controller or the operation indicator to inform the user of malfunctions detected.

Failure Recall Function

Operation failures are recorded, allowing confirmation when needed.

11 12

Page 8: Wrap Yourself in Comfort and Quiet - Mitsubishi Electric VN · MXY SERIES (Cooling Only) MXZ SERIES (Heat Pump) EXTERNAL DIMEMSIONS PIPING INSTALLATIONS CITY MULTI CITY MULTI S SERIES

FUNCTION LIST

VA

Opt

Opt

Opt

Opt

Opt

VA

*1

Opt

Opt

Opt

Opt

Opt

*2

VA

*1

Opt

Opt

Opt

Opt

Opt

*2

80

VA

*1

80

Opt

Opt

Opt

Opt

Opt

*2

80

VA

*1

Opt

Opt

Opt

Opt

Opt

*2

VA

*1

Opt

Opt

Opt

Opt

Opt

*2

Opt

VA

*1

Opt

Opt

Opt

Opt

Opt

*2

VEW

Opt

Opt

Opt

Opt

Opt

Opt

VEW

Opt

*1

Opt

Opt

Opt

Opt

Opt

*2

VEW

Opt

*1

Opt

Opt

Opt

Opt

Opt

*2

80

VEW

Opt

*1

80

Opt

Opt

Opt

Opt

Opt

*2

80

VEW

Opt

*1

Opt

Opt

Opt

Opt

Opt

*2

VEW

Opt

*1

Opt

Opt

Opt

Opt

Opt

*2

Opt

VEW

Opt

*1

Opt

Opt

Opt

Opt

Opt

*2

80

Opt

Opt

Opt

Opt

Opt

Opt

*1

Opt

Opt

Opt

Opt

Opt

22-50*2

*1

Opt

Opt

Opt

Opt

Opt

22-50*2

*1

80

Opt

Opt

Opt

Opt

Opt

*2

80

*1

Opt

Opt

Opt

Opt

Opt

*2

*1

Opt

Opt

Opt

Opt

Opt

*2

*1

Opt

Opt

Opt

Opt

Opt

*2

Opt22-50

Opt22-50

Opt22-50

Opt22-50

Opt22-50

Opt22-50

Opt60/71

Opt60

Opt60/71

Opt60/71

Opt60/71

22-50 22-50 22-50 22-50 22-50

Opt22-50Opt

60/71

22-50 22-50

60/71 60/71 60/71 60/71 60/71

60/71 60/7160 60/71 60/71 60/71

60/71 60/71 60/71 60/71 60/71

60/71 60/7160 60/71 60/71 60/71

*1

Opt

Opt

Opt

Opt

Opt

*2

*1

Opt

Opt

Opt

Opt

Opt

*2

80

*1

80

Opt

Opt

Opt

Opt

Opt

*2

80

*1

Opt

Opt

Opt

Opt

Opt

*2

*1

Opt

Opt

Opt

Opt

Opt

*2

Opt

*1

Opt

Opt

Opt

Opt

Opt

*2

35

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

*1

Opt

Opt

Opt

Opt

Opt

*2

*1

Opt

Opt

Opt

Opt

Opt

*2

80

*1

80

Opt

Opt

Opt

Opt

Opt

*2

80

*1

Opt

Opt

Opt

Opt

Opt

*2

*1

Opt

Opt

Opt

Opt

Opt

*2

Opt

*1

Opt

Opt

Opt

Opt

Opt

*2

Opt

Opt

*1

Opt

Opt

Opt

Opt

Opt

*2

Opt

Opt

*1

Opt

Opt

Opt

Opt

Opt

*2

80

Opt

Opt

*1

80

Opt

Opt

Opt

Opt

Opt

*2

80

Opt

Opt

*1

Opt

Opt

Opt

Opt

Opt

*2

Opt

Opt

*1

Opt

Opt

Opt

Opt

Opt

*2

Opt

Opt

Opt

*1

Opt

Opt

Opt

Opt

Opt

*2

VAQ

Opt

Opt

Opt

Opt

Opt

VAQ

*1

Opt

Opt

Opt

Opt

Opt

*2

VAQ

*1

Opt

Opt

Opt

Opt

Opt

*2

80

VAQ

*1

80

Opt

Opt

Opt

Opt

Opt

*2

80

VAQ

*1

Opt

Opt

Opt

Opt

Opt

*2

VAQ

*1

Opt

Opt

Opt

Opt

Opt

*2

Opt

VAQ

*1

Opt

Opt

Opt

Opt

Opt

*2

71

Opt

Opt

Opt

Opt

Opt

Opt

*1

Opt

Opt

Opt

Opt

Opt

*2

Opt

*1

Opt

Opt

Opt

Opt

Opt

*2

Opt

80

*1

80

Opt

Opt

Opt

Opt

Opt

*2

80

Opt

*1

Opt

Opt

Opt

Opt

Opt

*2

Opt

*1

Opt

Opt

Opt

Opt

Opt

*2

Opt

Opt

*1

Opt

Opt

Opt

Opt

Opt

*2

Opt

DC Inverter

Joint Lap DC Motor

Magnetic Flux Vector Sine Wave Drive

Reluctance DC Rotary Compressor

Highly Efficient DC Scroll Compressor

Rare Earth Magnet Rotor(Compressor)

DC Fan Motor

Vector-Wave Eco Inverter

PAM(Pulse Amplitude Modulation)

Power Receiver and Twin LEV Control

Grooved Piping

Felt Temperature Control (i-see Sensor)

AREA Temperature Monitor

Econo Cool Energy-saving Feature

'I-Feel' Control

Demand Function

Pure White

Auto Vane

Plasma Duo

Air Cleaning Filter

Fresh-air Intake

Anti-allergy Enzyme Filter

Electrostatic Anti-allergy Enzyme Filter

High-efficiency Filter

Catechin Filter

Nano Platinum Filter

Oil Mist Filter

Long-life Filter

Filter Check Signal

Horizontal Vane

Vertical Vane

High Ceiling Mode

Low Ceiling Mode

Auto Fan Speed Mode

Wide and Long Airflow

On/off Operation Timer

"i save" Mode

Auto Changeover

Auto Restart

Low-temperature Cooling

Low-noise Operation(Outdoor Unit)

Ampere Limit Adjustment

Operation Lock

Built-in Weekly Timer Function

Rotation, Back-up and 2nd Stage Cut-in Functions

PAR-30MAA Control *3

PAR-21MAA Control *3

Centraliesd On/Off Control *3

System Group Control *3

M-NET Connection *3

COMPO *4

MXZ Connection

Cleaning-free Pipe Reuse

Reuse of Existing Wiring

Wiring/Piping Correction Function

Drain Pump

Pump Down Switch

Flare Connection

Quick Clean Body

Self-Diagnosis Function(Check Code Display)

Failure Recall Function

Indoor unit

Outdoor unit

MSZ-FD20/35/50VA(S) MSZ-GE22/25/35/42/50/60/71VAMSZ-EF22/25/35/42/50VE(W)(B)(S) MSZ-SF15/20VA MFZ-KA25/35/50VA MLZ-KA25/35/50VA SLZ-KA25/35/50VAL/VAQ SEZ-KD25/35/50/60/71VAL/VAQMSC-

GE20/25/35VB

MSH-GE50

VB

MSH-GA60

VB

MSH-GD80

VB

MS-GE50

VB

MSZ-HC25/35

VA(B)

MUZ-FD

MXZ-2C

MXZ-3C

MXZ-4C

MXZ-5C

MXZ-8B

MXZ-6C

MUZ-GE

MUZ-EF

MXZ-2C

MXZ-3C

MXZ-4C

MXZ-5C

MXZ-6C

MXZ-8B

MXZ-2C

MXZ-3C

MXZ-4C

MXZ-5C

MXZ-8B

MXZ-6C

MXZ-2C

MXZ-3C

MXZ-4C

MXZ-5C

MXZ-8B

MXZ-6C

MUZ-HC

MUH-GA

MU-GA

MUH-GE

MUH-GA

MUH-GD

MU-GE

MS-GA60

VB

MS-GD80

VB

MU-GA

MU-GD

SUZ-KA

MXZ-2C

MXZ-3C

MXZ-4C

MXZ-5C

MXZ-8B

MXZ-6C

MXZ-2C

MXZ-3C

MXZ-4C

MXZ-5C

MXZ-8B

MXZ-6C

SUZ-KA

MXZ-2C

MXZ-3C

MXZ-4C

MXZ-5C

MXZ-8B

MXZ-6C

SUZ-KA

MXZ-2C

MXZ-3C

MXZ-4C

MXZ-5C

MXZ-8B

MXZ-6C

M SERIES M SERIES S SERIES

Technology

EnergySaving

Attractive

Air Quality

Air Distribution

Convenience

System Control

Installation

Maintenance

Fun

ctio

ns

Com

bina

tion

Category Icon

CategoryIndoor Unit MSZ-EF (25/35/50) MSZ-GE (25/35/50/60/71) MLZ-KA (25/35/50) PLA-RP (50/60/71) SEZ-KD (25/35/50/60/71)

Outdoor Unit MXZ-2C MXZ-3C MXZ-4C MXZ-5C MXZ-6C MXZ-2C MXZ-3C MXZ-4C MXZ-5C MXZ-6C MXZ-2C MXZ-3C MXZ-4C MXZ-5C MXZ-6C MXZ-3C MXZ-4C MXZ-5C MXZ-6C MXZ-2C MXZ-3C MXZ-4C MXZ-5C MXZ-6C

Technology

DC InverterJoint Lap DC MotorReluctance DC Rotary Compressor 4C80 4C80 4C80 4C80 4C80Rare Earth Magnet Rotor (Compressor)DC Fan MotorPAM (Pulse Amplitude Modulation)Power Receiver and Twin LEV ControlGrooved Piping

Functions

Energy Saving Econo Cool Energy-saving Feature

AttractivePure White VEW VEW VEW VEW VEWAuto Vane

Air Quality

Fresh-air IntakeAnti-allergy Enzyme Filter Opt 25-50 Opt 25-50 Opt 25-50 Opt 25-50 Opt 25-50 Opt Opt Opt Opt OptElectrostatic Anti-allergy Enzyme Filter Opt Opt Opt Opt Opt Opt 60 Opt 60/71 Opt 60/71 Opt 60/71High-efficiency Filter Opt Opt Opt OptCatechin Filter 25-50 25-50 25-50 25-50 25-50 Opt Opt Opt Opt OptNano Platinum Filter 60 60/71 60/71 60/71Long-life FilterFilter Check Signal

Air Distribution

Horizontal VaneVertical Mode 60 60/71 60/71 60/71High Ceiling ModeLow Ceiling ModeAuto Fan Speed ModeWide and Long Airflow 60 60/71 60/71 60/71

Convenience

On/Off Operation Timer"I save" ModeAuto Changeover *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1 *1Auto RestartLow-temperature CoolingLow-noise OperationAmpere Limit Adjustment 4C80 4C80 4C80 4C80 4C80Operation LockBuilt-in Weekly Timer Function 60 60/71 60/71 60/71

Installation

Cleaning-free Pipe ReuseWiring/Piping Correction Function 4C80 4C80 4C80 4C80 4C80Drain Pump Opt Opt Opt Opt OptFlare Connection

MaintenanceEasy CleanSelf-Diagonosis Function (Check Code Display)Failure Recall Function

*1 When multiple indoor units connected to an MXZ outdoor unit are runnning at the same time, simultaneours cooling and heating is not possible.*2 Smart Set is available for MSY-GE10/13/18VA, "i save" mode is available for MSY-GE24/26VA

CategoryIndoor Unit MSY-EF (10/13/18) MSY-GE (10/13/18/24/26) MLZ-KA (25/35/50) PLA-RP (50/60/71) SEZ-KD (25/35/50/60/71)

Outdoor Unit MXY-2E MXY-3A MXY-4A MXY-2E MXY-3A MXY-4A MXY-2E MXY-3A MXY-4A MXY-3A MXY-4A MXY-2E MXY-3A MXY-4A

Technology

DC InverterJoint Lap DC MotorReluctance DC Rotary Compressor 4A38 4A38 4A38 4A38Rare Earth Magnet Rotor (Compressor) 4A38DC Fan MotorPAM (Pulse Amplitude Modulation)Power Receiver and Twin LEV ControlGrooved Piping

Functions

Energy Saving Econo Cool Energy-saving Feature

AttractivePure White VAW VAW VAWAuto Vane

Air Quality

Fresh-air IntakeAnti-allergy Enzyme Filter Opt 10-18 Opt 10-18 Opt 10-18 Opt Opt OptElectrostatic Anti-allergy Enzyme Filter Opt Opt Opt Opt 24/26 Opt 24/26High-efficiency Filter Opt OptCatechin Filter 10-18 10-18 10-18 Opt Opt OptNano Platinum Filter 24/26 24/26Long-life FilterFilter Check Signal

Air Distribution

Horizontal VaneVertical Mode 24/26 24/26High Ceiling ModeLow Ceiling ModeAuto Fan Speed ModeWide and Long Airflow 24/26 24/26

Convenience

On/Off Operation Timer"i save" Mode / Smart Set *2 *2 *2Auto RestartLow-noise OperationAmpere Limit AdjustmentOperation LockBuilt-in Weekly Timer Function 24/26 24/26

Installation

Cleaning-free Pipe ReuseWiring/Piping Correction Function 4A38 4A38 4A38 4A38 4A38Drain Pump Opt Opt OptFlare Connection

MaintenanceEasy CleanSelf-Diagonosis Function (Check Code Display)Failure Recall Function

13 14

Page 9: Wrap Yourself in Comfort and Quiet - Mitsubishi Electric VN · MXY SERIES (Cooling Only) MXZ SERIES (Heat Pump) EXTERNAL DIMEMSIONS PIPING INSTALLATIONS CITY MULTI CITY MULTI S SERIES

SERIES

SELECTIONChoose from three types of indoor units and three types of outdoor units.Create the system that best matches the room shapes and the number of rooms.MXY SELECT INDOOR UNITS

Select the indoor unit to be installed in each room.

Wall-mounted Cassette Ceiling-concealed

SELECT OUTDOOR UNITSSelect the best outdoor unit based on the number of indoor units and overall system capacity required.

2-port Connect up to 2 indoor units

3-port Connect up to 3 indoor units

4-port Connect up to 4 indoor units

CHECK SYSTEM COMPATIBILITYPossible combinations depends on the outdoor unit chosen. Please check the following points.

Refer to the “Indoor Unit Compatibility Table” to check if the indoor units selected can be used with the outdoor unit selected. (Indoor units not listed in the table cannot be used.)

Refer to the “Combination Table” in data book to check if the capacity combination of the indoor unit selected is connectable. (Combinations not listed cannot be connected.)

Check Indoor Unit CapacityCombination

If the desired combination cannot be found, please change either the indoor or outdoor unit to match one of the combinations shown in the tables.

Check Indoor Units

MXY-2E20VA MXY-3A28VA MXY-4A28VA MXY-4A38VA

STEP 1

STEP 2

STEP 3

MSY-GE(24-26)

MSY-GE(10-18)

MSY-EF

PLA-RPMLZ-KA SEZ-KD

15 16

Page 10: Wrap Yourself in Comfort and Quiet - Mitsubishi Electric VN · MXY SERIES (Cooling Only) MXZ SERIES (Heat Pump) EXTERNAL DIMEMSIONS PIPING INSTALLATIONS CITY MULTI CITY MULTI S SERIES

MXYSERIESOur Inverter Technology adjusts capacity in response to conditions such as the difference between the outside and inside air temperatures, allowing our air conditioners to run more efficiently and reduce energy costs.

EXAMPLE SYSTEM

Handle Up to 4 Rooms with a Single Outdoor Unit

The MXY Series offers a four-system line-up to choose from, ranging between 5.0 and 9.2kW. All of them are compatible with specific M, S and P series indoor units. A single outdoor unit can handle a wide range of building layouts.

2-port 3-port 4-port

MXY-2E20VA

4-port

MXY-4A38VAMXY-3A28VAMXY-4A28VA

PLA-RP

MLZ-KA

MSY-GE

MSY-EF

MXY-4A38VA

Cooling Only MULTIMXY SERIES

4A38 3A/4A2A/3A

Type Inverter Cooling OnlyModel Name MXY-2E20VA MXY-3A28VA MXY-4A28VA MXY-4A38VA

Power Supply (V/Phase/Hz) 230/Single/50

CoolingCapacity

Rated kW 5.0 7.5 7.5 9.2Min - Max kW 1.10 - 6.55 2.9 - 8.9 3.7 - 8.9 3.7 - 11.2

Input Rated kW 1.44 2.18 2.16 2.45

Outdoor

DimensionsH × W × D mm 550 - 800 - 285 710 - 840 - 330 900 - 900 - 320Weight kg 38 57 58 67

Air Volume Cooling m3/min 31 42.1 42.1 42.2Sound Level (SPL) Cooling dB(A) 49 49 49 46Breaker Size A 15 25 25 25

Ext. Piping

DiameterLiquid mm 6.35 × 2 6.35 × 3 6.35 × 4 6.35 × 4Gas mm 9.52 × 2 9.52 × 3 9.52 × 3 + 12.7 × 1 9.52 × 3 + 12.7 × 1

Total Piping Length (max) m 30 60 60 70Each Indoor Unit Piping Length m 20 25 25 25Max. Height m 15 (10)* 15 (10)* 15 (10)* 15 (10)*

"Guaranteed Operating Range(Outdoor)" Cooling °C -10 ~ +46 -10 ~ +46 -10 ~ +46 -10 ~ +46

*If the outdoor unit is installed higher than the indoor unit, max. height is reduced to 10m.

MSY-GSERIESThe standard model MSY-G units provide excellent energy savings and operation is impressively silent. A vast series line-up is ready to ensure comfortable room environments in response to your air conditioning needs.

MSY-GE10/13/18VA MSY-GE24/26VA

Stylish and Compact

800mm

Fits neatly above800mm-wide doors.

Quiet OperationA “Silent Mode” setting has been added to the fan speed settings, ensuring super-quiet operation below 20dB for model sizes 13 and under. Perfect for the bedroom; it’s so quiet you’ll check to see if it’s on.

Wide Line-upFive different indoor units (Model 10-26) are available to meet your diversified air conditioning needs.

Nano Platinum FilterThis filter incorporates nanometre-sized platinum-ceramic particles that generate stable antibacterial and deodourising effects. The size of the three-dimensional surface has been increased as well, enlarg-ing the filter capture area. These features give the Nano Platinum Filter of the MSY-GE24/26 models better dust collection perfor-mance than conventional filters. The superior air-cleaning effective-ness raises room comfort yet another level.

It is okay to wash the filter with water(air-cleaning effect is maintained)

In the case of MSY-GE10-18Only 798mm

Only

19dB

MSY-GE10/13/18VA

MSY-GE24/26VA

10/13

3D surface (Waved surface)

An elegant, high-quality look is achieved through the new stylish design adopted for indoor units. The simple ergonomic square shape and pure white color express a sense of sophistication that matches well with virtually any interior décor.

MSY-GE10/13/18VA

24/26

24/26*2

NanoPlatinum

“i save” Mode“i save” is a simplified setting function that recalls the preferred (preset) temperature by pressing a single button on the remote con-troller. Press the same button twice in repetition to immediately return to the previous temperature setting. Using this function con-tributes to comfortable, waste-free operation, realizing the most suitable air conditioning settings and saving on power consumption when, for example, leaving the room or going to bed.

22oc 24ocCooling Cooling

MSY-E SERIESDeveloped to complement modern interior room décor, StarMEX ZEN air conditioners are available in three colors specially chosen to blend in naturally wherever installed.

Stylish Line-up MatchesAny Room Décor

The streamlined wall-mounted indoor units have eloquent silver-bevelled edges, expressing sophistication and quality. Combining impressively low power consumption and quiet yet powerful performance, these units provide a best-match scenario for diverse interior designs while simultane-eously ensuring maximum room and energy savings.

Multi Connection Single Connection

Quiet Comfort All Day LongMitsubishi Electric’s advanced “Silent Mode” fan speed setting pro-vides super-quiet operation as low as 21dB for EF10/13 models. This unique feature makes the StarMEX ZEN series ideal for use in any sit-uation.

Superior Exteriorand Operating Design Concept The indoor unit of the StarMEX ZEN keeps its amazingly thin form even during operation. The only physical change notable is the movement of the variable vent. As a result, a slim attractive look is maintained.

Closed Open� Noise Level

10dB40dB60dB80dB

Subway car interior

Quiet passenger car interior (40km/h)

Library interior

Human hearing limits

(Extremely quiet)Sound of

rustling leaves

Only 21dB(for EF10/13 models)

MSY-EF10/13/18VAW

MSY-EF10/13/18VAS

MSY-EF10/13/18VAB

White

Silver

Black

Built-in Weekly Timer Function

Easily sets desired temperatures and operation start/stop times to match lifestyle patterns. Reduce wasted energy consumption by using the timer to prevent forgetting to turn off the unit and eliminate temperature setting adjustments.

Type Cooling OnlyModel Name MSY-EF10VAW/B/S MSY-EF13VAW/B/S MSY-EF18VAW/B/S

Power Supply (V/Phase/Hz) Outdoor (230/Single/50)

CoolingAir Volume

Silent-Lo-Mid-Hi-SHi*m3/min 4.0 - 4.6 - 6.3 - 8.3 - 10.5 4.0 - 4.6 - 6.3 - 8.3 - 10.5 5.8 - 6.8 - 7.9 - 9.3 - 11.0

SPL dB(A) 21 - 23 - 29 - 36 - 42 21 - 24 - 29 - 36 - 42 30 - 33 - 36 - 40 - 43

Operating Current (max.) 0.14 0.14 0.18

Demensions H×W×D mm 299 - 895 - 195 299 - 895 - 195 299 - 895 - 195

Weight kg 11.5 11.5 11.5

Ext.Piping Diameter Liquid/Gas mm 6.35/9.52 6.35/9.52 6.35/12.7*SHi : Super High

Optional Optional

Optional

ElectrostaticAnti-allergy

Optional

NanoPlatinum

4A

17 18

Page 11: Wrap Yourself in Comfort and Quiet - Mitsubishi Electric VN · MXY SERIES (Cooling Only) MXZ SERIES (Heat Pump) EXTERNAL DIMEMSIONS PIPING INSTALLATIONS CITY MULTI CITY MULTI S SERIES

MSY-GSERIESThe standard model MSY-G units provide excellent energy savings and operation is impressively silent. A vast series line-up is ready to ensure comfortable room environments in response to your air conditioning needs.

MSY-GE10/13/18VA MSY-GE24/26VA

Stylish and Compact

800mm

Fits neatly above800mm-wide doors.

Quiet OperationA “Silent Mode” setting has been added to the fan speed settings, ensuring super-quiet operation below 20dB for model sizes 13 and under. Perfect for the bedroom; it’s so quiet you’ll check to see if it’s on.

Wide Line-upFive different indoor units (Model 10-26) are available to meet your diversified air conditioning needs.

Nano Platinum FilterThis filter incorporates nanometre-sized platinum-ceramic particles that generate stable antibacterial and deodourising effects. The size of the three-dimensional surface has been increased as well, enlarg-ing the filter capture area. These features give the Nano Platinum Filter of the MSY-GE24/26 models better dust collection perfor-mance than conventional filters. The superior air-cleaning effective-ness raises room comfort yet another level.

It is okay to wash the filter with water(air-cleaning effect is maintained)

In the case of MSY-GE10-18Only 798mm

Only

19dB

MSY-GE10/13/18VA

MSY-GE24/26VA

10/13

3D surface (Waved surface)

An elegant, high-quality look is achieved through the new stylish design adopted for indoor units. The simple ergonomic square shape and pure white color express a sense of sophistication that matches well with virtually any interior décor.

MSY-GE10/13/18VA

24/26

24/26*2

NanoPlatinum

“i save” Mode“i save” is a simplified setting function that recalls the preferred (preset) temperature by pressing a single button on the remote con-troller. Press the same button twice in repetition to immediately return to the previous temperature setting. Using this function con-tributes to comfortable, waste-free operation, realizing the most suitable air conditioning settings and saving on power consumption when, for example, leaving the room or going to bed.

22oc 24ocCooling Cooling

MSY-E SERIESDeveloped to complement modern interior room décor, StarMEX ZEN air conditioners are available in three colors specially chosen to blend in naturally wherever installed.

Stylish Line-up MatchesAny Room Décor

The streamlined wall-mounted indoor units have eloquent silver-bevelled edges, expressing sophistication and quality. Combining impressively low power consumption and quiet yet powerful performance, these units provide a best-match scenario for diverse interior designs while simultane-eously ensuring maximum room and energy savings.

Multi Connection Single Connection

Quiet Comfort All Day LongMitsubishi Electric’s advanced “Silent Mode” fan speed setting pro-vides super-quiet operation as low as 21dB for EF10/13 models. This unique feature makes the StarMEX ZEN series ideal for use in any sit-uation.

Superior Exteriorand Operating Design Concept The indoor unit of the StarMEX ZEN keeps its amazingly thin form even during operation. The only physical change notable is the movement of the variable vent. As a result, a slim attractive look is maintained.

Closed Open� Noise Level

10dB40dB60dB80dB

Subway car interior

Quiet passenger car interior (40km/h)

Library interior

Human hearing limits

(Extremely quiet)Sound of

rustling leaves

Only 21dB(for EF10/13 models)

MSY-EF10/13/18VAW

MSY-EF10/13/18VAS

MSY-EF10/13/18VAB

White

Silver

Black

Built-in Weekly Timer Function

Easily sets desired temperatures and operation start/stop times to match lifestyle patterns. Reduce wasted energy consumption by using the timer to prevent forgetting to turn off the unit and eliminate temperature setting adjustments.

Type Cooling OnlyModel Name MSY-GE10VA MSY-GE13VA MSY-GE18VA MSY-GE24VA*1 MSY-GE26VA

Power Supply (V/Phase/Hz) Outdoor (230/Single/50)

CoolingAir Volume Silent-Lo-

Mid-Hi-SHi*m3/min 4.2 - 4.9 - 6.7 - 8.9 - 11.4 4.2 - 4.9 - 6.7 - 9.2 - 12.8 6.5 - 7.8 - 9.6 - 11.8 - 15.1 N/A - 9.7 - 13.3 - 15.4 - 17.9 9.7 - 11.5 - 13.3 - 15.4 - 17.9

SPL dB(A) 19 - 21 - 29 - 36 - 40 19 - 22 - 30 - 36 - 45 28 - 33 - 38 - 44 - 49 N/A - 30 - 40 - 45 - 49 30 - 37 - 41 - 45 - 49

Operating Current (max.) 0.22 0.29 0.39 0.55 0.55

Demensions H×W×D mm 295 - 798 - 232 295 - 798 - 232 295 - 798 - 232 325 - 1100 - 238 325 - 1100 - 238

Weight kg 10 10 10 16 16

Ext.Piping Diameter Liquid/Gas mm 6.35/9.52 6.35/9.52 6.35/12.7 9.52/15.88 9.52/15.88*SHi : Super High*1 Functions and specification may differ depending on the market.*2 Smart Set is available for MSY-GE10/13/18VA.

MLZ SERIESIntroducing a new type of ceiling cassette for the Multi-Split Series with streamed interior dimensions and a sharp, sleek appearance.

175mm

Ceiling Mounted

Installing the ceiling-mounted MLZ Series unit in a room creates a more spacious feel that enhances room comfort. This overhead format is also an excellent solution when lighting equipment is installed at the centre of the room and fixtures such as book shelves are mounted on wall surfaces.

Slim Body

The new units are designed with a slim body (only 175mm high), en-suring easy installation even when low ceiling cavities limit installa-tion space. The need for ceiling cavity service space is also elimi-nated, further reducing the dimensions required for installation.

Easy Installation

A built-in drain pump (500mm lift) and flexible drain joints make attaching the drain hose in the ceiling cavity easy, resulting in simple and fast installation. Tight yet flexible fittings eliminate the need of wrapping with heat-insulation tape, and ensure that pipe and drain cover connections are free of condensation.

Insulating material wrapping only required from this point

Insulation material pretreatment eliminates need for wrapping.

The newly adopted insulation-free cover eliminates the need for wrapping pipes with insulation tape and prevents the forming of condensation.

Flexible drain joints simplify drain piping work in narrow ceiling areas

� Drain Piping SupportersInstallation Example

� Easy Mounting PlateSuspension work simplified with well-designed mounting plates

Built-in drain pump secures drainage water lift of 500mm

Access door not required

Drain cover

Easy joint connections!

Secure one side Move unit to the centre

Flexible drain joints Refrigerant pipe

MLZ-KA25/35/50VA

Air Volume Settings by Ceiling Height

Dual-level airflow selection is engineered to accommodate specific ceiling heights. This is a key feature for adjusting airflow effectively when it is either too strong or too weak due to being mismatched with the height of the ceiling.

Up and Down

Left and RightStandard

High ceiling

25

2.4m

2.7m

2.4m

2.7m

2.4m

2.7m

35 50

Auto Vane Control

Outlet vanes can be moved left and right, and up and down using the remote controller. This improved airflow control feature solves the problem of drafts.

Push the unit to the other side Secure the opposite side

SEZ SERIESThis concealed ceiling-mounted indoor unit series is compact, and fits easily into rooms with lowered ceilings. Highly reliable energy-saving performance makes it a best match choice for concealed unit installations.

Compact Ceiling-concealed Units

Only the intake-air grille and outlet vents are visible when using this ceiling-concealed indoor unit. The rest of the unit is conveniently hidden in the ceiling cavity, essentially leaving the ceiling and walls free of bulky looking devices and maintaining a high-class interior décor. The compact units require minimal space and can be installed in buildings with lowered ceilings, where exposed units were the rule in the past.

Wide Selection of Fan Speed and Static Pressure Level

Three fan speeds (Low - Mid - High) and four static pressure levels (5 - 15 - 35 - 50Pa) are available by using the DC fan motor to meet various needs.

Drain Pump (Optional)

The PAC-KE07DM-E drain pump is now available as an option. With the pump, a drain hose length of up to 550mm can be used, leading to increased installation possibilities.

Air inletAir outletAccess doorCeiling surfaceCanvas ductAir filterInlet grille

ABCDEFG

200

990

SEZ-KD35VAL

Dimension

SEZ-KD25-71VAL

Type Cooling OnlyModel Name MLZ-KA25VA MLZ-KA35VA MLZ-KA50VA

Power Supply (V/Phase/Hz) Outdoor (230/Single/50)

CoolingAir Volume

Lo-Mid-Him3/min 7.2 - 8.0 - 8.8 7.3 - 8.4 - 9.4 8.3 - 9.8 - 11.4

SPL dB(A) 29 - 32 - 35 31 - 34 - 37 34 - 38 - 43

Operating Current (max.) 0.4 0.4 0.4

Demensions H×W×D mm 175 - 1102 - 360 175 - 1102 - 360 175 - 1102 - 360

Weight kg 15 15 15

Ext.Piping Diameter Liquid/Gas mm 6.35/9.52 6.35/9.52 6.35/12.7

Optional

Optional Optional Optional

24/26 24/26 24/26*1 24/26*2

ElectrostaticAnti-allergy

Optional

24/2610 - 18 10 - 18 24/26

NanoPlatinum

4A

Optional Optional Optional Optional Optional

4A

19 20

Page 12: Wrap Yourself in Comfort and Quiet - Mitsubishi Electric VN · MXY SERIES (Cooling Only) MXZ SERIES (Heat Pump) EXTERNAL DIMEMSIONS PIPING INSTALLATIONS CITY MULTI CITY MULTI S SERIES

MLZ SERIESIntroducing a new type of ceiling cassette for the Multi-Split Series with streamed interior dimensions and a sharp, sleek appearance.

175mm

Ceiling Mounted

Installing the ceiling-mounted MLZ Series unit in a room creates a more spacious feel that enhances room comfort. This overhead format is also an excellent solution when lighting equipment is installed at the centre of the room and fixtures such as book shelves are mounted on wall surfaces.

Slim Body

The new units are designed with a slim body (only 175mm high), en-suring easy installation even when low ceiling cavities limit installa-tion space. The need for ceiling cavity service space is also elimi-nated, further reducing the dimensions required for installation.

Easy Installation

A built-in drain pump (500mm lift) and flexible drain joints make attaching the drain hose in the ceiling cavity easy, resulting in simple and fast installation. Tight yet flexible fittings eliminate the need of wrapping with heat-insulation tape, and ensure that pipe and drain cover connections are free of condensation.

Insulating material wrapping only required from this point

Insulation material pretreatment eliminates need for wrapping.

The newly adopted insulation-free cover eliminates the need for wrapping pipes with insulation tape and prevents the forming of condensation.

Flexible drain joints simplify drain piping work in narrow ceiling areas

� Drain Piping SupportersInstallation Example

� Easy Mounting PlateSuspension work simplified with well-designed mounting plates

Built-in drain pump secures drainage water lift of 500mm

Access door not required

Drain cover

Easy joint connections!

Secure one side Move unit to the centre

Flexible drain joints Refrigerant pipe

MLZ-KA25/35/50VA

Air Volume Settings by Ceiling Height

Dual-level airflow selection is engineered to accommodate specific ceiling heights. This is a key feature for adjusting airflow effectively when it is either too strong or too weak due to being mismatched with the height of the ceiling.

Up and Down

Left and RightStandard

High ceiling

25

2.4m

2.7m

2.4m

2.7m

2.4m

2.7m

35 50

Auto Vane Control

Outlet vanes can be moved left and right, and up and down using the remote controller. This improved airflow control feature solves the problem of drafts.

Push the unit to the other side Secure the opposite side

SEZ SERIESThis concealed ceiling-mounted indoor unit series is compact, and fits easily into rooms with lowered ceilings. Highly reliable energy-saving performance makes it a best match choice for concealed unit installations.

Compact Ceiling-concealed Units

Only the intake-air grille and outlet vents are visible when using this ceiling-concealed indoor unit. The rest of the unit is conveniently hidden in the ceiling cavity, essentially leaving the ceiling and walls free of bulky looking devices and maintaining a high-class interior décor. The compact units require minimal space and can be installed in buildings with lowered ceilings, where exposed units were the rule in the past.

Wide Selection of Fan Speed and Static Pressure Level

Three fan speeds (Low - Mid - High) and four static pressure levels (5 - 15 - 35 - 50Pa) are available by using the DC fan motor to meet various needs.

Drain Pump (Optional)

The PAC-KE07DM-E drain pump is now available as an option. With the pump, a drain hose length of up to 550mm can be used, leading to increased installation possibilities.

Air inletAir outletAccess doorCeiling surfaceCanvas ductAir filterInlet grille

ABCDEFG

200

990

SEZ-KD35VAL

Dimension

SEZ-KD25-71VAL

Type Cooling OnlyModel Name SEZ-KD25VAL SEZ-KD35VAL SEZ-KD50VAL SEZ-KD60VAL SEZ-KD71VAL

Power Supply (V/Phase/Hz) Outdoor (230/Single/50)

CoolingAir Volume

Lo-Mid-Him3/min 5.5 - 7.0 - 9.0 7.0 - 9.0 - 11.0 10.0 - 12.5 - 15.0 12.0 - 15.0 - 18.0 12.0 - 16.0 - 20.0

SPL dB(A) 23 - 26 - 30 23 - 28 - 33 30 - 34 - 37 30 - 34 - 38 30 - 35 - 40

Operating Current (max.) 0.39 0.46 0.63 0.63 0.84

Demensions H×W×D mm 200 - 790 - 700 200 - 990 - 700 200 - 990 - 700 200 - 1190 - 700 200 - 1190 - 700

Weight kg 18 21 23 27 27

Ext.Piping Diameter Liquid/Gas mm 6.35/9.52 6.35/9.52 6.35/12.7 6.35/15.88 9.52/15.88

External Static Pressure 5/15/35/50 5/15/35/50 5/15/35/50 5/15/35/50 5/15/35/50

PLA SERIESThe incorporation of wide air-outlet and the “i-see Sensor” enhances airflow distribution control, achieving an enhanced level of comfort throughout the room. The synergy of higher energy efficiency and more comfortable room environment results in the utmost user satisfaction.

PLA-RP50/60/71

New 4-Way Ceiling Cassette

Previousmodel

The New Swing Function Cools All Corners of the Room

Wave Airflow Operation“Wave Airflow” is essentially the advanced control of the vanesdirecting the airflow from the unit. Blown-air is repeated dispersed from the unit in horizontal and downward directions at time-lagged intervals to provide uniform heating throughout the room.

Optimum Airflow

Individual Vane SettingsOptimum airflow settings provide maximumcomfort throughout the room.In addition to the selection of variable airflow patterns (i.e., 2-, 3- or 4-way), this function allows the independent selection of vertical airflow levels for each vane, thereby maintaining a com-fortable room environment with even temperature distribution.

Wide AirflowWide-angle outlets distribute airflow to all corners of the room.The outlets are larger than those of previous models and the shape has been improved for better wide-angle ventilation.

DownwardDownward Downward Downward

Indoor Unit Indoor Unit

Temperature gapUneven temperature distribution

Horizontal Airflow Wave Airflow

Temperature distribution comparison approxi-mately 20min after turning on a PLA-RP71BA 4-Way ceiling cassette. The measurement point for comparison is a plane 1.2m above the floor.

Thermograph of Wave Control Effect

Minimized temperature gapUniform cool air is supplied throughout the room, minimizing uneven temperature distribution.

� Vertical swinging mode is adapted in the case of cooling operation

Airflow direction ateach vane can be set using the wired remote controller. Fixed

Adjustable

Horizontal

Downward

* Optional shuffle placement is required for 2- and 3-way patterns.

The combination of individual vane setting, which enables the optimal outlet setting for each room layout, and the wide airflow function works to ensure even temperature distribution throughout each room. The result is uniformly comfortable air conditioning.

Image of multi-directional air conditioning

72 airflow patterns

Individual VaneSetting

Wide Airflow

2-, 3-, 4-way airflow pattern selection

Type Cooling OnlyModel Name PLA-RP50BA PLA-RP60BA PLA-RP71BA

Power Supply (V/Phase/Hz) Outdoor (230/Single/50)

CoolingAir Volume Lo-Mid2-

Mid1-Him3/min 12.0 - 14.0 - 16.0 - 18.0 12.0 - 14.0 - 16.0 - 18.0 14.0 - 16.0 - 18.0 - 21.0

SPL dB(A) 28 - 29 - 31 - 32 28 - 29 - 31 - 32 28 - 30 - 32 - 34

Operating Current (max.) 0.36 0.36 0.51

Demensions H×W×D mm 258 - 840 - 840 258 - 840 - 840 258 - 840 - 840

Weight kg 22 23 23

Ext.Piping Diameter Liquid/Gas mm 6.35/12.7 6.35·9.52/15.88 9.52/15.88

Optional

4A

Optional Optional

Optional Optional Optional

4A

21 22

Page 13: Wrap Yourself in Comfort and Quiet - Mitsubishi Electric VN · MXY SERIES (Cooling Only) MXZ SERIES (Heat Pump) EXTERNAL DIMEMSIONS PIPING INSTALLATIONS CITY MULTI CITY MULTI S SERIES

PLA SERIESThe incorporation of wide air-outlet and the “i-see Sensor” enhances airflow distribution control, achieving an enhanced level of comfort throughout the room. The synergy of higher energy efficiency and more comfortable room environment results in the utmost user satisfaction.

PLA-RP50/60/71

New 4-Way Ceiling Cassette

Previousmodel

The New Swing Function Cools All Corners of the Room

Wave Airflow Operation“Wave Airflow” is essentially the advanced control of the vanesdirecting the airflow from the unit. Blown-air is repeated dispersed from the unit in horizontal and downward directions at time-lagged intervals to provide uniform heating throughout the room.

Optimum Airflow

Individual Vane SettingsOptimum airflow settings provide maximumcomfort throughout the room.In addition to the selection of variable airflow patterns (i.e., 2-, 3- or 4-way), this function allows the independent selection of vertical airflow levels for each vane, thereby maintaining a com-fortable room environment with even temperature distribution.

Wide AirflowWide-angle outlets distribute airflow to all corners of the room.The outlets are larger than those of previous models and the shape has been improved for better wide-angle ventilation.

DownwardDownward Downward Downward

Indoor Unit Indoor Unit

Temperature gapUneven temperature distribution

Horizontal Airflow Wave Airflow

Temperature distribution comparison approxi-mately 20min after turning on a PLA-RP71BA 4-Way ceiling cassette. The measurement point for comparison is a plane 1.2m above the floor.

Thermograph of Wave Control Effect

Minimized temperature gapUniform cool air is supplied throughout the room, minimizing uneven temperature distribution.

� Vertical swinging mode is adapted in the case of cooling operation

Airflow direction ateach vane can be set using the wired remote controller. Fixed

Adjustable

Horizontal

Downward

* Optional shuffle placement is required for 2- and 3-way patterns.

The combination of individual vane setting, which enables the optimal outlet setting for each room layout, and the wide airflow function works to ensure even temperature distribution throughout each room. The result is uniformly comfortable air conditioning.

Image of multi-directional air conditioning

72 airflow patterns

Individual VaneSetting

Wide Airflow

2-, 3-, 4-way airflow pattern selection

MSY-GE(24-26)

MSY-GE(10-18)

MSY-EF

PLA Series

MLZ Series

SEZ Series

Indoor Unit Compatibility Table

Indoor Unit

Outdoor Unit MXY-

2E20VA 3A28VA 4A28VA 4A38VA

Wall-mounted

Ceiling-concealed

4-way cassette

1-way cassette

MSY-EF10VA

MSY-EF13VA

MSY-EF18VA

MSY-GE10VA

MSY-GE13VA

MSY-GE18VA

MSY-GE24VA

MSY-GE26VA

MLZ-KA25VA

MLZ-KA35VA

MLZ-KA50VA

PLA-RP50BA

PLA-RP60BA

PLA-RP71BA

SEZ-KD35VAL

SEZ-KD50VAL

SEZ-KD60VAL

SEZ-KD71VAL

Possible combinations of outdoor units and indoor units are shown below.

23 24

Page 14: Wrap Yourself in Comfort and Quiet - Mitsubishi Electric VN · MXY SERIES (Cooling Only) MXZ SERIES (Heat Pump) EXTERNAL DIMEMSIONS PIPING INSTALLATIONS CITY MULTI CITY MULTI S SERIES

SELECTIONChoose from three types of indoor units and five types of outdoor units. Create the system that best matches the room shapes and the number of rooms.

SELECT INDOOR UNITSSelect the indoor unit to be installed in each room.

Wall-mounted Cassette Ceiling-concealed

SELECT OUTDOOR UNITSSelect the best outdoor unit based on the number of indoor units and overall system capacity required.

2-port Connect up to 2 indoor units

3-port Connect up to 3 indoor units

4-port Connect up to 4 indoor units

5-port Connect up to 5 indoor units 6-port Connect up to 6 indoor units

CHECK SYSTEM COMPATIBILITYPossible combinations depends on the outdoor unit chosen. Please check the following points.

Refer to the “Indoor Unit Compatibility Table” to check if the indoor units selected can be used with the outdoor unit selected. (Indoor units not listed in the table cannot be used.)

Refer to the “Combination Table” in data book to check if the capacity combination of the indoor unit selected is connectable. (Combinations not listed cannot be connected.)

Check Indoor Unit CapacityCombination

If the desired combination cannot be found, please change either the indoor or outdoor unit to match one of the combinations shown in the tables.

Check Indoor Units

MXZ-2C52VA

MXZ-5C100VA MXZ-6C120VA

MXZ-3C68VA MXZ-4C71VA MXZ-4C80VA

STEP 1

STEP 2

STEP 3

MSZ-GE(60/71)

MSZ-GE(25/35/50)

MSZ-EF

PLA-RPMLZ-KA SEZ-KD

SERIESMXZ

25 26

Page 15: Wrap Yourself in Comfort and Quiet - Mitsubishi Electric VN · MXY SERIES (Cooling Only) MXZ SERIES (Heat Pump) EXTERNAL DIMEMSIONS PIPING INSTALLATIONS CITY MULTI CITY MULTI S SERIES

MXZ SERIESAdvancements in the MXZ Series include efficiency and flexibility in system expansion capabilities. The best solution when requiring multi-system air conditioning needs.

EXAMPLE SYSTEM

Handle Up to 6 Rooms with a Single Outdoor Unit

The MXZ Series offers a six-system line-up to choose from, ranging between 5.2 and 12.0kW. All of them are compatible with specific M, S and P series indoor units. A single outdoor unit can handle a wide range of building layouts.

4-port 5-port 6-port2-port

MXZ-2C52VA MXZ-4C80VAMXZ-5C100VA

3-port 4-port

MXZ-3C68VAMXZ-4C71VA

MXZ-6C120VA

MSZ-GE

MLZ-KA

(example of MXZ-6C120VA system)

MSZ-GE

MSZ-EF

MXZ-6C120VA

INVERTER MULTIMXZ SERIES

2C/3C/4C4C80-6C 3C - 6C

PLA-BA

SEZ-KD

Type Inverter Heat PumpModel Name MXZ-2C52VA MXZ-3C68VA MXZ-4C71VA MXZ-4C80VA MXZ-5C100VA MXZ-6C120VA

Power Supply (V/Phase/Hz) 230/Single/50

CoolingCapacity

Rated kW 5.2 6.8 7.1 8.0 10.0 12.0Min - Max kW 1.1 - 6.0 2.9 - 8.4 3.7 - 8.8 3.7 - 9.2 3.9 - 11.0 3.5 - 13.5

Input Rated kW 1.3 1.78 1.68 1.955 2.80 3.61

HeatingCapacity

Rated kW 6.4 8.6 8.6 9.4 12.0 14.0Min - Max kW 1.0 - 7.0 2.6 - 10.6 3.4 - 10.7 3.4 - 11.6 4.1 - 14.0 3.5 - 16.5

Input Rated kW 1.61 2.05 1.71 1.93 2.84 3.47

Outdoor

DimensionsH × W × D mm 550 - 800 - 285 710 - 840 - 330 900 - 900 - 320 1070 - 900 - 320Weight kg 38 57 58 67 68 88

Air VolumeCooling m3/min 32.9 42.1 42.1 42.1 56.6 55.4Heating m3/min 33.3 43 43 43.8 59.3 69.9

Sound Level (SPL)

Cooling dB(A) 49 48 48 46 51 55Heating dB(A) 50 52 52 48 54 57

Breaker Size A 15 25 25 25 25 32

Ext. Piping

DiameterLiquid mm 6.35 × 2 6.35 × 3 6.35 × 4 6.35 × 4 6.35 × 5 6.35 × 6Gas mm 9.52 × 2 9.52 × 3 9.52 × 3 + 12.7 × 1 9.52 × 3 + 12.7 × 1 9.52 × 4 + 12.7 × 1 9.52 × 5 + 12.7 × 1

Total Piping Length (max) m 30 60 60 70 80 80

Each Indoor Unit Piping Length m 20 25 25 25 25 25

Max. Height m 15 (10)* 15 (10)* 15 (10)* 15 (10)* 15 (10)* 15 (10)*

"Guaranteed Operating Range(Outdoor)"

Cooling °C -10 ~ +43 -10 ~ +43 -10 ~ +43 -10 ~ +43 -10 ~ +43 -10 ~ +43Heating °C -15 ~ +24 -15 ~ +24 -15 ~ +24 -15 ~ +24 -15 ~ +24 -15 ~ +24

* If the outdoor unit is installed higher than the indoor unit, max.height is reduced to 10m.

MSZ-GSERIESThe standard model MSZ-G units provide excellent energy savings and operation is impressively silent. A vast series line-up is ready to ensure comfortable room environments in response to your air conditioning needs.

MSZ-GE25/35/50VA MSZ-GE60/71VA

Stylish and Compact

800mm

Fits neatly above800mm-wide doors.

Quiet OperationA “Silent Mode” setting has been added to the fan speed settings, ensuring super-quiet operation below 20dB for model sizes 35 and under. Perfect for the bedroom; it’s so quiet you’ll check to see if it’s on.

Wide Line-upFive different indoor units (Model 25-71) are available to meet your diversified air conditioning needs.

Nano Platinum FilterThis filter incorporates nanometre-sized platinum-ceramic particles that generate stable antibacterial and deodourising effects. The size of the three-dimensional surface has been increased as well, enlarg-ing the filter capture area. These features give the Nano Platinum Filter of the MSZ-GE60/71 models better dust collection perfor-mance than conventional filters. The superior air-cleaning effective-ness raises room comfort yet another level.

It is okay to wash the filter with water(air-cleaning effect is maintained)

In the case of MSZ-GE25-50Only 798mm

Only

19dB

MSZ-GE25/35/50VA

MSZ-GE60/71VA

25-35

3D surface (Waved surface)

An elegant, high-quality look is achieved through the new stylish design adopted for indoor units. The simple ergonomic square shape and pure white color express a sense of sophistication that matches well with virtually any interior décor.

MSZ-GE25/35/50VA

60/71

NanoPlatinum

“i save” Mode“i save” is a simplified setting function that recalls the preferred (preset) temperature by pressing a single button on the remote con-troller. Press the same button twice in repetition to immediately return to the previous temperature setting. Using this function con-tributes to comfortable, waste-free operation, realizing the most suitable air conditioning settings and saving on power consumption when, for example, leaving the room or going to bed.

22oc 18ocHeating Heating

MSZ-E SERIESDeveloped to complement modern interior room décor, Kirigamine ZEN air conditioners are available in three colors specially chosen to blend in naturally wherever installed.

Stylish Line-up MatchesAny Room Décor

The streamlined wall-mounted indoor units have eloquent silver-bevelled edges, expressing sophistication and quality. Combining impressively low power consumption and quiet yet powerful performance, these units provide a best-match scenario for diverse interior designs while simultane-eously ensuring maximum room and energy savings

Multi Connection Single Connection

Quiet Comfort All Day LongMitsubishi Electric’s advanced “Silent Mode” fan speed setting pro-vides super-quiet operation as low as 21dB for EF25/35 models. This unique feature makes the Kirigamine ZEN series ideal for use in any situation.

Built-in Weekly Timer Function

SettingEasily sets desired temperatures and operation start/stop times to match lifestyle patterns. Reduces wasted energy consumption by using the timer to prevent forgetting to turn off the unit and eliminate temperature setting adjustments.

The remote controller is equipped with buttons that are used exclusively for setting the Weekly Timer. Setting operation patterns easy and quick.

Superior Exteriorand Operating Design Concept The indoor unit of the Kirigamine ZEN keeps its amazingly thin form even during operation. The only physical change notable is the movement of the variable vent. As a result, a slim attractive look is maintained.

Closed Open� Noise Level

10dB40dB60dB80dB

Subway car interior

Quiet passenger car interior (40km/h)

Library interior

Human hearing limits

(Extremely quiet)Sound of

rustling leaves

� Easy Set-up Using Dedicated Buttons

Only 21dB(for EF25/35 models)

MSZ-EF25/35/50VEW

MSZ-EF25/35/50VES

MSZ-EF25/35/50VEB

White

Silver

Black

A maximum of 4ON or OFF timers can be set for individual days of the weekA maximum of 28 ON or OFF timers can be set for a week.

Mon

Fri

Setting1ON

6:00

Setting2OFF

8:3024°C 27°C

Setting3ON

17:30

Setting4OFF

22:00

Sat

Sun

Setting1ON

8:00

Setting2OFF

21:00

E.g. : Runs at 24°C from waking up to leaving home, and runs at 27°C fromgetting home to going to bed on weekdays.Runs at 27°C from waking up late to going bed early on weekends

27°C

Type Inverter Heat PumpModel Name MSZ-EF25VEW/B/S MSZ-EF35VEW/B/S MSZ-EF50VEW/B/S

Power Supply (V/Phase/Hz) Outdoor (230/Single/50)

CoolingAir Volume m3/min 4.0 - 4.6 - 6.3 - 8.3 - 10.5 4.0 - 4.6 - 6.3 - 8.3 - 10.5 5.8 - 6.8 - 7.9 - 9.3 - 11.0SPL Silent-Lo-Mid-Hi-SHi* dB(A) 21 - 23 - 29 - 36 - 42 21 - 24 - 29 - 36 - 42 30 - 33 - 36 - 40 - 43

HeatingAir Volume m3/min 4.0 - 4.6 - 6.2 - 8.9 - 11.9 4.0 - 4.6 - 6.2 - 8.9 - 12.7 6.4 - 7.3 - 9.0 - 11.1 - 13.2SPL Silent-Lo-Mid-Hi-Shi* dB(A) 21 - 24 - 29 - 37 - 45 21 - 24 - 30 - 38 - 46 30 - 33 - 37 - 43 - 49

Operating Current (max.) 0.3 0.3 0.4

Demensions H×W×D mm 299 - 895 - 195 299 - 895 - 195 299 - 895 - 195

Weight kg 11.5 11.5 11.5

Ext.Piping Diameter Liquid/Gas mm 6.35/9.52 6.35/9.52 6.35/12.7*SHi : Super High

Optional Optional

Optional

ElectrostaticAnti-allergy

Optional

NanoPlatinum

4C/5C/6C4C/5C/6C

27 28

Page 16: Wrap Yourself in Comfort and Quiet - Mitsubishi Electric VN · MXY SERIES (Cooling Only) MXZ SERIES (Heat Pump) EXTERNAL DIMEMSIONS PIPING INSTALLATIONS CITY MULTI CITY MULTI S SERIES

MSZ-GSERIESThe standard model MSZ-G units provide excellent energy savings and operation is impressively silent. A vast series line-up is ready to ensure comfortable room environments in response to your air conditioning needs.

MSZ-GE25/35/50VA MSZ-GE60/71VA

Stylish and Compact

800mm

Fits neatly above800mm-wide doors.

Quiet OperationA “Silent Mode” setting has been added to the fan speed settings, ensuring super-quiet operation below 20dB for model sizes 35 and under. Perfect for the bedroom; it’s so quiet you’ll check to see if it’s on.

Wide Line-upFive different indoor units (Model 25-71) are available to meet your diversified air conditioning needs.

Nano Platinum FilterThis filter incorporates nanometre-sized platinum-ceramic particles that generate stable antibacterial and deodourising effects. The size of the three-dimensional surface has been increased as well, enlarg-ing the filter capture area. These features give the Nano Platinum Filter of the MSZ-GE60/71 models better dust collection perfor-mance than conventional filters. The superior air-cleaning effective-ness raises room comfort yet another level.

It is okay to wash the filter with water(air-cleaning effect is maintained)

In the case of MSZ-GE25-50Only 798mm

Only

19dB

MSZ-GE25/35/50VA

MSZ-GE60/71VA

25-35

3D surface (Waved surface)

An elegant, high-quality look is achieved through the new stylish design adopted for indoor units. The simple ergonomic square shape and pure white color express a sense of sophistication that matches well with virtually any interior décor.

MSZ-GE25/35/50VA

60/71

NanoPlatinum

“i save” Mode“i save” is a simplified setting function that recalls the preferred (preset) temperature by pressing a single button on the remote con-troller. Press the same button twice in repetition to immediately return to the previous temperature setting. Using this function con-tributes to comfortable, waste-free operation, realizing the most suitable air conditioning settings and saving on power consumption when, for example, leaving the room or going to bed.

22oc 18ocHeating Heating

MSZ-E SERIESDeveloped to complement modern interior room décor, Kirigamine ZEN air conditioners are available in three colors specially chosen to blend in naturally wherever installed.

Stylish Line-up MatchesAny Room Décor

The streamlined wall-mounted indoor units have eloquent silver-bevelled edges, expressing sophistication and quality. Combining impressively low power consumption and quiet yet powerful performance, these units provide a best-match scenario for diverse interior designs while simultane-eously ensuring maximum room and energy savings

Multi Connection Single Connection

Quiet Comfort All Day LongMitsubishi Electric’s advanced “Silent Mode” fan speed setting pro-vides super-quiet operation as low as 21dB for EF25/35 models. This unique feature makes the Kirigamine ZEN series ideal for use in any situation.

Built-in Weekly Timer Function

SettingEasily sets desired temperatures and operation start/stop times to match lifestyle patterns. Reduces wasted energy consumption by using the timer to prevent forgetting to turn off the unit and eliminate temperature setting adjustments.

The remote controller is equipped with buttons that are used exclusively for setting the Weekly Timer. Setting operation patterns easy and quick.

Superior Exteriorand Operating Design Concept The indoor unit of the Kirigamine ZEN keeps its amazingly thin form even during operation. The only physical change notable is the movement of the variable vent. As a result, a slim attractive look is maintained.

Closed Open� Noise Level

10dB40dB60dB80dB

Subway car interior

Quiet passenger car interior (40km/h)

Library interior

Human hearing limits

(Extremely quiet)Sound of

rustling leaves

� Easy Set-up Using Dedicated Buttons

Only 21dB(for EF25/35 models)

MSZ-EF25/35/50VEW

MSZ-EF25/35/50VES

MSZ-EF25/35/50VEB

White

Silver

Black

A maximum of 4ON or OFF timers can be set for individual days of the weekA maximum of 28 ON or OFF timers can be set for a week.

Mon

Fri

Setting1ON

6:00

Setting2OFF

8:3024°C 27°C

Setting3ON

17:30

Setting4OFF

22:00

Sat

Sun

Setting1ON

8:00

Setting2OFF

21:00

E.g. : Runs at 24°C from waking up to leaving home, and runs at 27°C fromgetting home to going to bed on weekdays.Runs at 27°C from waking up late to going bed early on weekends

27°C

Type Inverter Heat PumpModel Name MSZ-GE25VA MSZ-GE35VA MSZ-GE50VA MSZ-GE60VA MSZ-GE71VA

Power Supply (V/Phase/Hz) Outdoor (230/Single/50)

CoolingAir Volume Silent-Lo-

Mid-Hi-SHi*m3/min 4.1 - 4.8 - 6.7 - 9.1 - 11.3 4.1 - 4.8 - 6.7 - 9.1 - 12.7 6.5 - 7.8 - 9.6 - 11.9 - 15.1 9.8 - 11.3 - 13.4 - 15.6 - 18.3 9.7 - 11.5 - 13.3 - 15.4 - 17.8

SPL dB(A) 19 - 21 - 29 - 36 - 42 19 - 22 - 30 - 36 - 43 28 - 33 - 38 - 44 - 49 29 - 37 - 41 - 45 - 49 30 - 37 - 41 - 45 - 49

HeatingAir Volume Silent-Lo-

Mid-Hi-Shi*m3/min 4.1 - 4.8 - 6.6 - 9.1 - 11.5 4.1 - 4.8 - 6.7 - 9.1 - 11.5 6.5 - 7.9 - 9.6 - 12.2 - 14.5 9.8 - 11.3 - 13.4 - 15.6 - 18.3 10.2 - 11.5 - 13.3 - 15.4 - 17.8

SPL dB(A) 19 - 21 - 29 - 36 - 42 19 - 22 - 30 - 36 - 42 28 - 33 - 37 - 43 - 48 29 - 37 - 41 - 45 - 49 30 - 37 - 41 - 45 - 49

Operating Current (max.) 0.4 0.4 0.5 0.5 0.5

Demensions H×W×D mm 295 - 798 - 232 295 - 798 - 232 295 - 798 - 232 325 - 1100 - 238 325 - 1100 - 238

Weight kg 10 10 10 16 16

Ext.Piping Diameter Liquid/Gas mm 6.35/9.52 6.35/9.52 6.35/12.7 6.35/15.88 9.52/15.88*SHi : Super High

MLZ SERIESIntroducing a new type of ceiling cassette for the Multi-Split Series with streamed interior dimensions and a sharp, sleek appearance.

175mm

Ceiling Mounted

Installing the ceiling-mounted MLZ Series unit in a room creates a more spacious feel that enhances room comfort. This overhead format is also an excellent solution when lighting equipment is installed at the centre of the room and fixtures such as book shelves are mounted on wall surfaces.

Slim Body

The new units are designed with a slim body (only 175mm high), en-suring easy installation even when low ceiling cavities limit installa-tion space. The need for ceiling cavity service space is also elimi-nated, further reducing the dimensions required for installation.

Easy Installation

A built-in drain pump (500mm lift) and flexible drain joints make attaching the drain hose in the ceiling cavity easy, resulting in simple and fast installation. Tight yet flexible fittings eliminate the need of wrapping with heat-insulation tape, and ensure that pipe and drain cover connections are free of condensation.

Insulating material wrapping only required from this point

Insulation material pretreatment eliminates need for wrapping.

The newly adopted insulation-free cover eliminates the need for wrapping pipes with insulation tape and prevents the forming of condensation.

Flexible drain joints simplify drain piping work in narrow ceiling areas

� Drain Piping SupportersInstallation Example

� Easy Mounting PlateSuspension work simplified with well-designed mounting plates

Built-in drain pump secures drainage water lift of 500mm

Access door not required

Drain cover

Easy joint connections!

Secure one side Move unit to the centre

Flexible drain joints Refrigerant pipe

MLZ-KA25/35/50VA

Air Volume Settings by Ceiling Height

Dual-level airflow selection is engineered to accommodate specific ceiling heights. This is a key feature for adjusting airflow effectively when it is either too strong or too weak due to being mismatched with the height of the ceiling.

Up and Down

Left and RightStandard

High ceiling

25

2.4m

2.7m

2.4m

2.7m

2.4m

2.7m

35 50

Auto Vane Control

Outlet vanes can be moved left and right, and up and down using the remote controller. This improved airflow control feature solves the problem of drafts.

Push the unit to the other side Secure the opposite side

SEZ SERIESThis concealed ceiling-mounted indoor unit series is compact, and fits easily into rooms with lowered ceilings. Highly reliable energy-saving performance makes it a best match choice for concealed unit installations.

Compact Ceiling-concealed Units

Only the intake-air grille and outlet vents are visible when using this ceiling-concealed indoor unit. The rest of the unit is conveniently hidden in the ceiling cavity, essentially leaving the ceiling and walls free of bulky looking devices and maintaining a high-class interior décor. The compact units require minimal space and can be installed in buildings with lowered ceilings, where exposed units were the rule in the past.

Drain Pump (Optional)

The PAC-KE07DM-E drain pump is now available as an option. With the pump, a drain hose length of up to 550mm can be used, leading to increased installation possibilities.

Air inletAir outletAccess doorCeiling surfaceCanvas ductAir filterInlet grille

ABCDEFG

200

990

SEZ-KD35VAL

Dimension

SEZ-KD25-71VAL

Wide Selection of Fan Speed and Static Pressure Level

Three fan speeds (Low - Mid - High) and four static pressure levels (5 - 15 - 35 - 50Pa) are available by using the DC fan motor to meet various needs.

Type Inverter Heat PumpModel Name MLZ-KA25VA MLZ-KA35VA MLZ-KA50VA

Power Supply (V/Phase/Hz) Outdoor (230/Single/50)

CoolingAir Volume

Lo-Mid-Him3/min 7.2 - 8.0 - 8.8 7.3 - 8.4 - 9.4 8.3 - 9.8 - 11.4

SPL dB(A) 29 - 32 - 35 31 - 34 - 37 34 - 38 - 43

HeatingAir Volume

Lo-Mid-Him3/min 7.0 - 8.2 - 9.2 7.7 - 8.8 - 9.9 8.8 - 10.3 - 11.8

SPL dB(A) 28 - 32 - 36 31 - 35 - 38 34 - 39 - 43

Operating Current (max.) 0.4 0.4 0.4

Demensions H×W×D mm 175 - 1102 - 360 175 - 1102 - 360 175 - 1102 - 360

Weight kg 15 15 15

Ext.Piping Diameter Liquid/Gas mm 6.35/9.52 6.35/9.52 6.35/12.7

Optional

Optional Optional Optional

60/71 60/71 60/71

ElectrostaticAnti-allergy

Optional

60/71 60/7125 - 50

4C/5C/6C 4C/5C/6C

25 - 50

NanoPlatinum

Optional Optional Optional Optional Optional4C/5C/6C

4C/5C/6C

29 30

Page 17: Wrap Yourself in Comfort and Quiet - Mitsubishi Electric VN · MXY SERIES (Cooling Only) MXZ SERIES (Heat Pump) EXTERNAL DIMEMSIONS PIPING INSTALLATIONS CITY MULTI CITY MULTI S SERIES

MLZ SERIESIntroducing a new type of ceiling cassette for the Multi-Split Series with streamed interior dimensions and a sharp, sleek appearance.

175mm

Ceiling Mounted

Installing the ceiling-mounted MLZ Series unit in a room creates a more spacious feel that enhances room comfort. This overhead format is also an excellent solution when lighting equipment is installed at the centre of the room and fixtures such as book shelves are mounted on wall surfaces.

Slim Body

The new units are designed with a slim body (only 175mm high), en-suring easy installation even when low ceiling cavities limit installa-tion space. The need for ceiling cavity service space is also elimi-nated, further reducing the dimensions required for installation.

Easy Installation

A built-in drain pump (500mm lift) and flexible drain joints make attaching the drain hose in the ceiling cavity easy, resulting in simple and fast installation. Tight yet flexible fittings eliminate the need of wrapping with heat-insulation tape, and ensure that pipe and drain cover connections are free of condensation.

Insulating material wrapping only required from this point

Insulation material pretreatment eliminates need for wrapping.

The newly adopted insulation-free cover eliminates the need for wrapping pipes with insulation tape and prevents the forming of condensation.

Flexible drain joints simplify drain piping work in narrow ceiling areas

� Drain Piping SupportersInstallation Example

� Easy Mounting PlateSuspension work simplified with well-designed mounting plates

Built-in drain pump secures drainage water lift of 500mm

Access door not required

Drain cover

Easy joint connections!

Secure one side Move unit to the centre

Flexible drain joints Refrigerant pipe

MLZ-KA25/35/50VA

Air Volume Settings by Ceiling Height

Dual-level airflow selection is engineered to accommodate specific ceiling heights. This is a key feature for adjusting airflow effectively when it is either too strong or too weak due to being mismatched with the height of the ceiling.

Up and Down

Left and RightStandard

High ceiling

25

2.4m

2.7m

2.4m

2.7m

2.4m

2.7m

35 50

Auto Vane Control

Outlet vanes can be moved left and right, and up and down using the remote controller. This improved airflow control feature solves the problem of drafts.

Push the unit to the other side Secure the opposite side

SEZ SERIESThis concealed ceiling-mounted indoor unit series is compact, and fits easily into rooms with lowered ceilings. Highly reliable energy-saving performance makes it a best match choice for concealed unit installations.

Compact Ceiling-concealed Units

Only the intake-air grille and outlet vents are visible when using this ceiling-concealed indoor unit. The rest of the unit is conveniently hidden in the ceiling cavity, essentially leaving the ceiling and walls free of bulky looking devices and maintaining a high-class interior décor. The compact units require minimal space and can be installed in buildings with lowered ceilings, where exposed units were the rule in the past.

Drain Pump (Optional)

The PAC-KE07DM-E drain pump is now available as an option. With the pump, a drain hose length of up to 550mm can be used, leading to increased installation possibilities.

Air inletAir outletAccess doorCeiling surfaceCanvas ductAir filterInlet grille

ABCDEFG

200

990

SEZ-KD35VAL

Dimension

SEZ-KD25-71VAL

Wide Selection of Fan Speed and Static Pressure Level

Three fan speeds (Low - Mid - High) and four static pressure levels (5 - 15 - 35 - 50Pa) are available by using the DC fan motor to meet various needs.

Type Inverter Heat PumpModel Name SEZ-KD25VAL SEZ-KD35VAL SEZ-KD50VAL SEZ-KD60VAL SEZ-KD71VAL

Power Supply (V/Phase/Hz) Outdoor (230/Single/50)

Heating and Cooling

Air VolumeLo-Mid-Hi

m3/min 5.5 - 7.0 - 9.0 7.0 - 9.0 - 11.0 10.0 - 12.5 - 15.0 12.0 - 15.0 - 18.0 12.0 - 16.0 - 20.0SPL dB(A) 23 - 26 - 30 23 - 28 - 33 30 - 34 - 37 30 - 34 - 38 30 - 35 - 40

Operating Current (max.) 0.39 0.46 0.63 0.63 0.84

Demensions H×W×D mm 200 - 790 - 700 200 - 990 - 700 200 - 990 - 700 200 - 1190 - 700 200 - 1190 - 700

Weight kg 18 21 23 27 27

Ext.Piping Diameter Liquid/Gas mm 6.35/9.52 6.35/9.52 6.35/12.7 6.35/15.88 9.52/15.88

External Static Pressure 5/15/35/50 5/15/35/50 5/15/35/50 5/15/35/50 5/15/35/50

PLA SERIESThe incorporation of wide air-outlet and the “i-see Sensor” enhances airflow distribution control, achieving an enhanced level of comfort throughout the room. The synergy of higher energy efficiency and more comfortable room environment results in the utmost user satisfaction.

PLA-RP50/60/71

New 4-Way Ceiling Cassette

Previousmodel

Wave Airflow – Thoroughly Warming All Corners of the Room!

Wave Airflow Operation“Wave Airflow” is essentially the advanced control of the vanesdirecting the airflow from the unit. Blown-air is repeated dispersed from the unit in horizontal and downward directions at time-lagged intervals to provide uniform heating throughout the room.

Optimum Airflow

Individual Vane SettingsOptimum airflow settings provide maximumcomfort throughout the room.In addition to the selection of variable airflow patterns (i.e., 2-, 3- or 4-way), this function allows the independent selection of vertical airflow levels for each vane, thereby maintaining a com-fortable room environment with even temperature distribution.

Wide AirflowWide-angle outlets distribute airflow to all corners of the room.The outlets are larger than those of previous models and the shape has been improved for better wide-angle ventilation.

DownwardDownward Downward Downward

Indoor Unit Indoor Unit

Temperature gapUneven temperature distribution

Horizontal Airflow Wave Airflow

Temperature distribution comparison approxi-mately 20min after turning on a PLA-RP71BA 4-Way ceiling cassette. The measurement point for comparison is a plane 1.2m above the floor.

Thermograph of Wave Control Effect

Minimized temperature gapWarm air is supplied throughout the room, minimizing uneven temperature distribution.

� Wave Airflow is possible only when using the heating mode

Airflow direction ateach vane can be set using the wired remote controller. Fixed

Adjustable

Horizontal

Downward

* Optional shuffle placement is required for 2- and 3-way patterns.

The combination of individual vane setting, which enables the optimal outlet setting for each room layout, and the wide airflow function works to ensure even temperature distribution throughout each room. The result is uniformly comfortable air conditioning.

Image of multi-directional air conditioning

72 airflow patterns

Individual VaneSetting

Wide Airflow

2-, 3-, 4-way airflow pattern selection

Type Inverter Heat PumpModel Name PLA-RP50BA PLA-RP60BA PLA-RP71BA

Power Supply (V/Phase/Hz) Outdoor (230/Single/150)

Heating and Cooling

Air VolumeLo-Mid2-Mid1-Hi

m3/min 12.0 - 14.0 - 16.0 - 18.0 12.0 - 14.0 - 16.0 - 18.0 14.0 - 16.0 - 18.0 - 21.0SPL dB(A) 28 - 29 - 31 - 32 28 - 29 - 31 - 32 28 - 30 - 32 - 34

Operating Current (max.) 0.36 0.36 0.51

Demensions H×W×D mm 258 - 840 - 840 258 - 840 - 840 258 - 840 - 840

Weight kg 22 23 23

Ext.Piping Diameter Liquid/Gas mm 6.35/12.7 6.35·9.52/15.88 9.52/15.88

Optional Optional Optional

4C/5C/6C 4C/5C/6C

Optional

4C/5C/6C 4C/5C/6C

Optional Optional

31 32

Page 18: Wrap Yourself in Comfort and Quiet - Mitsubishi Electric VN · MXY SERIES (Cooling Only) MXZ SERIES (Heat Pump) EXTERNAL DIMEMSIONS PIPING INSTALLATIONS CITY MULTI CITY MULTI S SERIES

PLA SERIESThe incorporation of wide air-outlet and the “i-see Sensor” enhances airflow distribution control, achieving an enhanced level of comfort throughout the room. The synergy of higher energy efficiency and more comfortable room environment results in the utmost user satisfaction.

PLA-RP50/60/71

New 4-Way Ceiling Cassette

Previousmodel

Wave Airflow – Thoroughly Warming All Corners of the Room!

Wave Airflow Operation“Wave Airflow” is essentially the advanced control of the vanesdirecting the airflow from the unit. Blown-air is repeated dispersed from the unit in horizontal and downward directions at time-lagged intervals to provide uniform heating throughout the room.

Optimum Airflow

Individual Vane SettingsOptimum airflow settings provide maximumcomfort throughout the room.In addition to the selection of variable airflow patterns (i.e., 2-, 3- or 4-way), this function allows the independent selection of vertical airflow levels for each vane, thereby maintaining a com-fortable room environment with even temperature distribution.

Wide AirflowWide-angle outlets distribute airflow to all corners of the room.The outlets are larger than those of previous models and the shape has been improved for better wide-angle ventilation.

DownwardDownward Downward Downward

Indoor Unit Indoor Unit

Temperature gapUneven temperature distribution

Horizontal Airflow Wave Airflow

Temperature distribution comparison approxi-mately 20min after turning on a PLA-RP71BA 4-Way ceiling cassette. The measurement point for comparison is a plane 1.2m above the floor.

Thermograph of Wave Control Effect

Minimized temperature gapWarm air is supplied throughout the room, minimizing uneven temperature distribution.

� Wave Airflow is possible only when using the heating mode

Airflow direction ateach vane can be set using the wired remote controller. Fixed

Adjustable

Horizontal

Downward

* Optional shuffle placement is required for 2- and 3-way patterns.

The combination of individual vane setting, which enables the optimal outlet setting for each room layout, and the wide airflow function works to ensure even temperature distribution throughout each room. The result is uniformly comfortable air conditioning.

Image of multi-directional air conditioning

72 airflow patterns

Individual VaneSetting

Wide Airflow

2-, 3-, 4-way airflow pattern selection

MSZ-GE(60/71)

MSZ-GE(25/35/50)

MSZ-EF

PLA Series

MLZ Series

SEZ Series

Indoor Unit Compatibility Table

Indoor Unit

Outdoor Unit MXZ-

2C52VA 3C68VA 4C71VA 4C80VA

Wall-mounted

4-way cassette

Ceiling-concealed

1-way cassette

MSZ-EF25VE

MSZ-EF35VE

MSZ-EF50VE

MSZ-GE25VA

MSZ-GE35VA

MSZ-GE50VA

MSZ-GE60VA

MSZ-GE71VA

MLZ-KA25VA

MLZ-KA35VA

MLZ-KA50VA

PLA-RP50BA

PLA-RP60BA

PLA-RP71BA

SEZ-KD25VAL

SEZ-KD35VAL

SEZ-KD50VAL

SEZ-KD60VAL

SEZ-KD71VAL

5C100VA 6C120VA

Possible combinations of outdoor units and indoor units are shown below.

33

Page 19: Wrap Yourself in Comfort and Quiet - Mitsubishi Electric VN · MXY SERIES (Cooling Only) MXZ SERIES (Heat Pump) EXTERNAL DIMEMSIONS PIPING INSTALLATIONS CITY MULTI CITY MULTI S SERIES

Unit : mm

External Dimensions

60

193

18

299

59 678 15894

100

110

7

58(80)

895875 10

47

Air out

Installation plate

Piping

Drain hose

Air in

MSY-GE10VA MSY-GE13VA MSY-GE18VA MSZ-GE25VA MSZ-GE35VA MSZ-GE50VA

19

159

58

798785 6.5

13061950

295

42

8100

107

112

56 69

Air in

Air out

Installation plate

Piping

Drain hose

INDOOR UNIT

5232

INDOOR UNIT

MSY-GE24VA MSY-GE26VA MSZ-GE60VA MSZ-GE71VA

INDOOR UNIT

MSY-EF10VA MSY-EF13VA MSY-EF18VAMSZ-EF25VE MSZ-EF35VE MSZ-EF50VE

1090 51100

76 843 181

60

193

18

65

67

325

3100

125160

( 70 )

238

5

184

12

Air out

Piping

Drain hose

Air in

Installation plate

Wall-Mounted

34

Page 20: Wrap Yourself in Comfort and Quiet - Mitsubishi Electric VN · MXY SERIES (Cooling Only) MXZ SERIES (Heat Pump) EXTERNAL DIMEMSIONS PIPING INSTALLATIONS CITY MULTI CITY MULTI S SERIES

SERIES

Light weightEasy to transport and install at site. Smaller footprint

Flexible choice and suitable for the limited outdoor space.

4HP x 2units

By the entrance On the balcony

8HP x 1units

Extended residence space.

8HP

The two-pipe zoned system designed for Heat Pump OperationThe CITY MULTI S series make use of a two-pipe refrigerant system, which allows for system changeover from cooling to

heating, ensuring that a constant indoor climate is maintained in all zones. The compact outdoor unit utilizes R410A refriger-

ant and an INVERTER-driven compressor to use energy effectively.

With a wide range of indoor unit line-up in connection with a flexible piping system, the CITY MULTI series can be configured

for all applications. Up to 12 indoor units can be connected with up to 130% connected capacity to maximize engineer's

design options. This feature allows easy air conditioning in each area with convenient individual controllers.

Total lengthMaximum allowable lengthFarthest indoor from first branch

300150 (175 equivalent)30

Indoor/outdoor (outdoor higher)Indoor/outdoor (outdoor lower)Indoor/indoor

50 4015

Outdoor unit

Indoor unit

Between indoor units top-bottom differential15m

Refrigerant Piping Lengths Maximum meters

[P112~140(V/YKM)]

Furthest piping length 175m (equivalent length) (actual length 150m)

Vertical differentials between units Maximum meters

Top-bottom differential 50m

Total lengthMaximum allowable lengthFarthest indoor from first branch

15080 (90 equivalent)30

Indoor/outdoor (outdoor higher)Indoor/outdoor (outdoor lower)Indoor/indoor

50 40 15

Outdoor unit

Indoor unit

Between indoor units top-bottom differential15m

Refrigerant Piping Lengths Maximum meters

[P175~225(YKM)]

Furthest piping length 90m(equivalent length) (actual length 80m)

Vertical differentials between units Maximum meters

Top-bottom differential 50m

Highly efficient fan and grille for outdoor unit

The shapes of the fan and grille of the outdoor unit have been rede-signed, realising an increase in blowing capacity and more efficient heat exchange while maintaining the same operating noise level.

AdvancedEnergy-savingTechnologies PUMY-P VKM

PUMY-P YKMS series

Highly efficient heat exchanger

A high density and increase in surface area have improved the heat-exchange efficiency of the heat exchanger.

Heat Interchanger (HIC) Added

A HIC circuit has been added to improve energy effi-ciency during cooling operation. Liquid refrigerant is rerouted, transformed into a gas state and injected back into the system to increase overall pressure of the refrigerant being sent to the compressor, thereby reducing the load on the compressor and raising effi-ciency.

The diameter of the opening for the fan in the outdoor unit has been in-creased from 490 to 550mm. Blowing capacity has been increased while maintaining the same fan rotation speed.

Opening increasedfrom 490 to 550mm in diameter

Outdoor unit fan opening increased

The pipe diameter has been changed from 9.52 to 7.94mm, resulting in a high-density heat exchanger.

High-density heat exchanger

Heat exchanger size extended horizontally, increasing the surface area.

Heat-exchange surface area increased

The shape of the air outlet grille has been changed to reduce pressure loss. This has helped to improve heat exchange perfor-mance.

Grille shape changed

Adoption of a fan with improved ventilation characteris-tics and a newly designed rear edge that suppresses wind turbulence raises fan operation efficiency.

Inflexed fan

PUMY-P V/YHMB PUMY-P V/YKM Fan rear edge

2 lines, 52 columns

2 lines, 64 columns

Heat exchanger Heat exchanger

Increase in heat-exchanger surface area

PUMY-P V/YHMB

(image)

PUMY-P V/YKM

w/ HIC circuitw/o HIC circuit

Heat Interchanger (HIC)

A

LEV C LEV A

LEV B

Heatinterchanger(HIC)

IndoorHEX

OutdoorHEX

Accumulator

Compressor

Cooling operation

HIC without to increase the heat exchange volume with increasing I.

I_current

I_new

A

Outdoor unit

Residence

8HPNew S series

New S series can maximize residential area.

Eas

y to

tra

nsp

ort

by

elev

ato

r

Welcome

Light and easy to carry

Silent mode can reduce sound pressure level by 3dB(A)

43 44

Page 21: Wrap Yourself in Comfort and Quiet - Mitsubishi Electric VN · MXY SERIES (Cooling Only) MXZ SERIES (Heat Pump) EXTERNAL DIMEMSIONS PIPING INSTALLATIONS CITY MULTI CITY MULTI S SERIES

System ControllerMITSUBISHI ELECTRIC's Air-conditioner Network System (MELANS) leads air conditioner management a PCbrowser and Network era.

OUTDOOR UNIT S SeriesSpecifications

External DimensionsPUMY-P112V(Y)KMPUMY-P175YKM

PUMY-P125V(Y)KMPUMY-P200YKM

PUMY-P140V(Y)KMPUMY-P225YKM

PUMY-P112/125/140VKM

PUMY-P175/200/225YKM

Model

393

426

PUMY-P112/125/140YKM 426

C

450

510

510

B

986

1062

909

A

3-phase 380-415V 50Hz

25.0

85,300

9.62

15.72-14.93-14.39

2.60

15.0~24.0°C

-5.0~46.0°C

27.3

93,200

7.65

12.50-11.87-11.44

3.57

15.0~27.0°C

-20.0~15.0°C

50~130 % of outdoor unit capacity

P15~P250 / 12

58 / 63

9.52 Flare *3

22.2 Brazed

143.8

2,397

5,078

1,338 x 1,050 x 330 (+25)

R410A 7.3kg

138

PUMY-P225YKM

3-phase 380-415V 50Hz

22.4

76,400

6.91

11.29-10.72-10.34

3.24

15.0~24.0°C

-5.0~46.0°C

25.0

85,300

6.96

11.37-10.80-10.41

3.59

15.0~27.0°C

-20.0~15.0°C

50~130 % of outdoor unit capacity

P15~P250 / 12

56 / 61

9.52 Flare *3

22.2 Brazed

134

2,233

4,732

1,338 x 1,050 x 330 (+25)

R410A 7.3kg

138

PUMY-P200YKM

3-phase 380-415V 50Hz

20.0

68,200

5.48

8.95-8.51-8.20

3.65

15.0~24.0°C

-5.0~46.0°C

22.4

76,400

5.73

9.36-8.89-8.57

3.91

15.0~27.0°C

-20.0~15.0°C

50~130 % of outdoor unit capacity

P15~P224 / 12

56/ 61

9.52 Flare *3

22.2 Brazed

134

2,233

4,732

1,338 x 1,050 x 330 (+25)

R410A 7.3kg

138

PUMY-P175YKM

Power source

Cooling capacity(Nominal)

*1 kW

*1 BTU / h

Power input kW

Current input A

EER kW / kW

Temp. range ofcooling

Indoor temp. W.B.

Outdoor temp. D.B.

Heating capacity(Nominal)

*2 kW

*2 BTU / h

Power input kW

Current input A

COP kW / kW

Temp. range ofheating

Indoor temp. D.B.

Outdoor temp. W.B.

Indoor unitconnectable

Total capacity

Model / Quantity

Sound pressure level (measured in anechoic room) dB <A>

Refrigerant pipingdiameter

Liquid pipe mm

Gas pipe mm

FAN Air flow rate m3 /min

L/s

cfm

External dimension HxWxDmm

Refrigerant Type x original charge

Net weight kg

Model

Power source

Cooling capacity (Nominal)

*1 kW

*1 BTU / h

Power input kW

Current input A

EER kW / kW

Temp. range ofcooling

Indoor temp. W.B.

Outdoor temp. D.B.

Heating capacity(Nominal)

*2 kW

*2 BTU / h

Power input kW

Current input A

COP kW / kW

Temp. range ofheating

Indoor temp. D.B.

Outdoor temp. W.B.

Indoor unitconnectable

Total capacity

Model / Quantity

Sound pressure level (measured in anechoic room) dB <A>

Refrigerant pipingdiameter

Liquid pipe mm

Gas pipe mm

FAN Air flow rate m3 /min

L/s

cfm

External dimension HxWxDmm

Refrigerant Type x original charge

Net weight kg

Model

Notes: *1,*2 Nominal conditions

*Nominal condition *1,*2 are subject to ISO 15042.

*Due to continuing improvement, above specification may be subject to change without notice.

*3 Liquid pipe diameter:12.7mm in case of farthest piping length is longer than 60m.

Indoor Outdoor

Cooling 27ºC DB/19ºCWB 35ºC DB

Heating 20ºC DB 7ºC DB/6ºC WB

Pipe length Level difference

Cooling 7.5m 0m

Heating 7.5m 0m

1-phase 220-240V 50Hz 1-phase 220-240V 50Hz 1-phase 220-240V 50Hz

12.5 14.0 15.5

42,700 47,800 52,900

2.79 3.46 4.52

12.87-12.32-11.80 15.97-15.27-14.64 20.86-19.95-19.12

4.48 4.05 3.43

15.0~24.0°C 15.0~24.0°C 15.0~24.0°C

-5.0~46.0°C -5.0~46.0°C -5.0~46.0°C

14.0 16.0 18.0

47,800 54,600 61,400

3.04 3.74 4.47

14.03-13.42-12.86 17.26-16.51-15.82 20.63-19.73-18.91

4.61 4.28 4.03

15.0~27.0°C 15.0~27.0°C 15.0~27.0°C

-20.0~15.0°C -20.0~15.0°C -20.0~15.0°C

50~130 % of outdoor unit capacity 50~130 % of outdoor unit capacity 50~130 % of outdoor unit capacity

P15~P140 / 9 P15~P140 / 10 P15~P140 / 12

49 / 51 50 / 52 51 / 53

9.52 Flare 9.52 Flare 9.52 Flare

15.88 Flare 15.88 Flare 15.88 Flare

110 110 110

1,833 1,833 1,833

3,884 3,884 3,884

1,338 x 1,050 x 330 (+25) 1,338 x 1,050 x 330 (+25) 1,338 x 1,050 x 330 (+25)

R410A 4.8kg R410A 4.8kg R410A 4.8kg

123 123 123

PUMY-P112VKM PUMY-P125VKM PUMY-P140VKM

3-phase 380-415V 50Hz

12.5

42,700

2.79

4.46-4.24-4.09

4.48

15.0~24.0°C

-5.0~46.0°C

14.0

47,800

3.04

4.86-4.62-4.45

4.61

15.0~27.0°C

-20.0~15.0°C

50~130 % of outdoor unit capacity

P15~P140 / 9

49 / 51

9.52 Flare

15.88 Flare

110

1,833

3,884

1,338 x 1,050 x 330 (+25)

R410A 4.8kg

125

PUMY-P112YKM

3-phase 380-415V 50Hz

14.0

47,800

3.46

5.53-5.26-5.07

4.05

15.0~24.0°C

-5.0~46.0°C

16.0

54,600

3.74

5.98-5.68-5.48

4.28

15.0~27.0°C

-20.0~15.0°C

50~130 % of outdoor unit capacity

P15~P140 / 10

50 / 52

9.52 Flare

15.88 Flare

110

1,833

3,884

1,338 x 1,050 x 330 (+25)

R410A 4.8kg

125

PUMY-P125YKM

3-phase 380-415V 50Hz

15.5

52,900

4.52

7.23-6.87-6.62

3.43

15.0~24.0°C

-5.0~46.0°C

18.0

61,400

4.47

7.15-6.79-6.55

4.03

15.0~27.0°C

-20.0~15.0°C

50~130 % of outdoor unit capacity

P15~P140 / 12

51 / 53

9.52 Flare

15.88 Flare

110

1,833

3,884

1,338 x 1,050 x 330 (+25)

R410A 4.8kg

125

PUMY-P140YKM

Air Intake

Front piping cover

Rear piping cover

Installation Feet

2-U Shaped notched holes(Foundation Bolt M10)

2-12×36 Oval holes(Foundation Bolt M10)

Side Air Intake

Rear Air Intake

Air Discharge70(75*)

42

56(60*)

417

225

2533

0

600 225

2819

370

53

56330

1

2

From left to right

For concentrationcontrol

For the transmission line

For the *1 branch boxpower supply

Terminal connection

For the power supply

Ground for *1the branch box power supply

Handle formoving

Handle formoving

Ground for the transmission lineGround for concentration control

Ground for the power supply("GR"marking position)

Service panel

362

1050

26

1338

C *2

*3

B *2

A

369

632

*1 PUMY-P112/125/140V(Y)KM only.*2 Indication of STOP VALVE connection location.*3 PUMY-P175/200/225YKM:(Flare) 19.05(3/4F)

1 Refrigerant GAS pipe connectionPUMY-P112/125/140V(Y)KM:(Flare) 15.88PUMY-P175/200/225YKM:(attached JOINT) 22.2

2 Refrigerant LIQUID pipe connection:(Flare) 9.52

* PUMY-P175/200/225YKM

Unit : mm

OUTDOOR UNIT

Light weightEasy to transport and install at site. Smaller footprint

Flexible choice and suitable for the limited outdoor space.

4HP x 2units

By the entrance On the balcony

8HP x 1units

Extended residence space.

8HP

The two-pipe zoned system designed for Heat Pump OperationThe CITY MULTI S series make use of a two-pipe refrigerant system, which allows for system changeover from cooling to

heating, ensuring that a constant indoor climate is maintained in all zones. The compact outdoor unit utilizes R410A refriger-

ant and an INVERTER-driven compressor to use energy effectively.

With a wide range of indoor unit line-up in connection with a flexible piping system, the CITY MULTI series can be configured

for all applications. Up to 12 indoor units can be connected with up to 130% connected capacity to maximize engineer's

design options. This feature allows easy air conditioning in each area with convenient individual controllers.

Total lengthMaximum allowable lengthFarthest indoor from first branch

300150 (175 equivalent)30

Indoor/outdoor (outdoor higher)Indoor/outdoor (outdoor lower)Indoor/indoor

50 4015

Outdoor unit

Indoor unit

Between indoor units top-bottom differential15m

Refrigerant Piping Lengths Maximum meters

[P112~140(V/YKM)]

Furthest piping length 175m (equivalent length) (actual length 150m)

Vertical differentials between units Maximum meters

Top-bottom differential 50m

Total lengthMaximum allowable lengthFarthest indoor from first branch

15080 (90 equivalent)30

Indoor/outdoor (outdoor higher)Indoor/outdoor (outdoor lower)Indoor/indoor

50 40 15

Outdoor unit

Indoor unit

Between indoor units top-bottom differential15m

Refrigerant Piping Lengths Maximum meters

[P175~225(YKM)]

Furthest piping length 90m(equivalent length) (actual length 80m)

Vertical differentials between units Maximum meters

Top-bottom differential 50m

Highly efficient fan and grille for outdoor unit

The shapes of the fan and grille of the outdoor unit have been rede-signed, realising an increase in blowing capacity and more efficient heat exchange while maintaining the same operating noise level.

AdvancedEnergy-savingTechnologies PUMY-P VKM

PUMY-P YKMS series

Highly efficient heat exchanger

A high density and increase in surface area have improved the heat-exchange efficiency of the heat exchanger.

Heat Interchanger (HIC) Added

A HIC circuit has been added to improve energy effi-ciency during cooling operation. Liquid refrigerant is rerouted, transformed into a gas state and injected back into the system to increase overall pressure of the refrigerant being sent to the compressor, thereby reducing the load on the compressor and raising effi-ciency.

The diameter of the opening for the fan in the outdoor unit has been in-creased from 490 to 550mm. Blowing capacity has been increased while maintaining the same fan rotation speed.

Opening increasedfrom 490 to 550mm in diameter

Outdoor unit fan opening increased

The pipe diameter has been changed from 9.52 to 7.94mm, resulting in a high-density heat exchanger.

High-density heat exchanger

Heat exchanger size extended horizontally, increasing the surface area.

Heat-exchange surface area increased

The shape of the air outlet grille has been changed to reduce pressure loss. This has helped to improve heat exchange perfor-mance.

Grille shape changed

Adoption of a fan with improved ventilation characteris-tics and a newly designed rear edge that suppresses wind turbulence raises fan operation efficiency.

Inflexed fan

PUMY-P V/YHMB PUMY-P V/YKM Fan rear edge

2 lines, 52 columns

2 lines, 64 columns

Heat exchanger Heat exchanger

Increase in heat-exchanger surface area

PUMY-P V/YHMB

(image)

PUMY-P V/YKM

w/ HIC circuitw/o HIC circuit

Heat Interchanger (HIC)

A

LEV C LEV A

LEV B

Heatinterchanger(HIC)

IndoorHEX

OutdoorHEX

Accumulator

Compressor

Cooling operation

HIC without to increase the heat exchange volume with increasing I.

I_current

I_new

A

Outdoor unit

Residence

8HPNew S series

New S series can maximize residential area.

Eas

y to

tra

nsp

ort

by

elev

ato

r

Welcome

Light and easy to carry

Silent mode can reduce sound pressure level by 3dB(A)

45 46

Page 22: Wrap Yourself in Comfort and Quiet - Mitsubishi Electric VN · MXY SERIES (Cooling Only) MXZ SERIES (Heat Pump) EXTERNAL DIMEMSIONS PIPING INSTALLATIONS CITY MULTI CITY MULTI S SERIES

Wide Selection of Indoor Units

ModelModel nameModel name P15 P20 P25 P32 P40 P50 P63 P71 P80 P100 P125 P140 P200 P250

Ceiling Cassette

Ceiling Concealed

Ceiling Suspended

Wall Mounted

Floor Standing/Floor Mounted Concealed

Fresh Air Intake

1-way air flow

2-way air flow

4-way air flow PLFY-P VBM-E

PLFY-P VCM-E2

PLFY-P VLMD-E

PMFY-P VBM-E

PEFY-P VMR-E-L/R

PEFY-P VMS1(L)-E

PEFY-P VMA(L)-E

PEFY-P VMA3-E

PEFY-P VMH(S)-E

PEFY-P VMH-E-F

PCFY-P VKM-E

PKFY-P VBM-E

PKFY-P VHM-E

PKFY-P VKM-E

PFFY-P VKM-E2

PFFY-P VLEM-E

PFFY-P VLRM-EPFFY-P VLRMM-E

47 48

Page 23: Wrap Yourself in Comfort and Quiet - Mitsubishi Electric VN · MXY SERIES (Cooling Only) MXZ SERIES (Heat Pump) EXTERNAL DIMEMSIONS PIPING INSTALLATIONS CITY MULTI CITY MULTI S SERIES

C entralized Remote ControllerI ndividual Remote Controller

LMAP04-E

Interface

LONWORKS ® *2

transmission line

EthernetIntegrated centralized control software TG-2000A

All of the local remote controllers feature liquid crystal and LED displays and easy to operate.

RemoteController

SimpleRemoteController

Wireless Remote Controller

PAR-31MAAE

PAR-FA32MA

PAR-SA9FA-E PAR-SL94B-E

PAC-YT52CRA

PAR-FL32MA

A ir-Conditioning Control System

This is a specialized air condition-ing management system, in which up to 2000 indoor units can be centrally controlled.

ON/OFFRemote Controller

PAC-YT40ANRA

AdvancedTouch Controller

AT-50B

PAC-YG60MCA

PAC-YG66DCA

PAC-YG63MCA

AI Controller

DIDO Controller

PI Controller

Mitsubishi Electric's CITY MULTI can be easily connected to the building management system through BACnet .

AG-150AAE-200E/AE-50E

GB-50ADA-J

PAC-YG50ECA

BAC-HD150

Interface

BACnet ® *1

transmission line(Ethernet)

Integrated centralized control software TG-2000A

*Some controllers cannot be used in combination with certain models of devices.*1 BACnet ® is a registered trademark of ASHRAE.*2 LonWorks® is a trademark of Echelon Corporation registered in the United States and other countries.

*1. Advanced HVAC CONTROLLER

*1

PAR-U02MEDA

PAC-IF01AHC-J

AHC ADAPTER

EB-50GU-J

OUTDOOR UNIT INDOOR UNITPLFYPMFYPEFY

: PUMY: PUCY/PUHY

SY

PCFYPKFYPFFY

NEWNEW

System ControllerMitsubishi Electric's Air-conditioner Network System (MELANS) introduces an era of air conditioner management via PC browsers connected to a Network.

The New Cooling-only ModelsMitsubishi Electric offers a wide lineup of new cooling-only models with themaximum capacity of 54 HP*. Different patterns of combinations of basic modules provide either standard or high COP. *Applicable to standard model combinations only

MELANS

Use of our MELANS products enhances EFFICIENCY and QUALITY of air-conditioning, contributing to ENERGY SAVING and reduction in running cost. We offer a wide variety of MELANS products to meet all requirements - from the smallest and simplest to the largest and most complex.We have individual remote controllers, various centralized controllers, and centralized integrated software, as well as BMS interface hardware and software etc. Above all, with AE-200E/AE-50E/AG-150A/EB-50GU-J/GB-50ADA-J, PC browser and long distance remote control (monitoring and operating) via communication Network is possible and easy.

Single module up 20 HP

Capable of covering up to 20 HP with a single module and a single compressor. Reduced piping work.

Compatibility to outdoor temperature of up to 52°C*1

Capable of running cooling operations in the outdoor temperature of up to 52°C*.*Compared to 46°C of the older model

Increase in the limit of piping length

Farthest indoor from first branch: 90 m Height difference between indoor and indoor units is up to 30 m.

Standard or high COP options are available by different combinations of modules.

Farthest indoor from first branch: 90 m Height difference between indoor and indoor units is up to 30 m.

*1 : Any continuous operation over 46ºC may require an increased frequency of maintenance.*2 : When the height difference is 15m or greater, use the one size larger liquid pipe between the indoor unit and the indoor unit.*3 : When the piping length is 40m or longer, use the one size larger liquid pipe between the indoor unit and the first branch.

All modules feature inverter-driven compressors.Maximum combined horse power: 60 HP

Current New52ºC

8 10 12 14 16 18 20

S L XL

HP

example : 30HP

12 18 30

S +

+ =

L

8

S +

+ 8 14 30+ =

S + L

COP3.33

COP3.88

Standardmodel

HighCOPmodel

20HP10HP 10HP

Field-installed Field-installed

Requires joint work

No need for joint work

Max length

First Branch

90m

Max height

30m *2

*3

M-N

ET

System ControllerMITSUBISHI ELECTRIC's Air-conditioner Network System (MELANS) leads air conditioner management a PCbrowser and Network era.

System Structure

MELANS

Use of our MELANS products enhances EFFICIENCY and QUALITY of air-conditioning, contributing to ENERGY SAVING and reduction in running cost. We offer a wide variety of MELANS products to meet all requirements - from the smallest and simplest to the largest and most complex.We have individual remote controllers, various centralized controllers, and centralized integrated software, as well as BMS interface hardware and software etc. Above all, with AE-200E/AE-50E/AG-150A/EB-50GU-J/GB-50ADA-J, PC browser and long distance remote control (monitoring and operating) via communication Network is possible and easy.

*1. Please contact your local distributor for when the feature is supported.

BMSBuilding management system

HUB

HUBPC

M-NET M-NET

group 1 group 2

group 3 group 4

M-NET

AE-200E

TabletBACnet®

To be connectable with BACnet® *1

LAN1 : For air conditioning systemsLAN2 : For BACnet®

LAN2

LAN1

LAN2

LAN1

LAN2

LAN1

LAN2

LAN1

Router

HUB

AE-50E

AE-50E

AE-50E

DIDO Controller (PAC-YG66DCA)

General Equipment

Temp/Humidity sensor

Watt hour meter

AI Controller (PAC-YG63MCA)

PI Controller (PAC-YG60MCA)

Power supply unit(PAC-SC51KUA)

Lights Ventilation Security card reader

In an easy and flexible manner with our new Centralized Controller AE-200E, an optimum system can be established according to the scale of facilities.

M-N

ET

49 50

Page 24: Wrap Yourself in Comfort and Quiet - Mitsubishi Electric VN · MXY SERIES (Cooling Only) MXZ SERIES (Heat Pump) EXTERNAL DIMEMSIONS PIPING INSTALLATIONS CITY MULTI CITY MULTI S SERIES

INDOOR UNITMLZ-KA25VA MLZ-KA35VA MLZ-KA50VA

Center of ceiling opening, suspension bolt pitch and grille are located in one position.

Hole position for theinstallation of grille

Electrical box

1051 Suspension bolt pitch

Air outlet

Wirelessremote controller

Grille (MLP-440W)

Electrical box

Receiving section

Drain pipe

Display and receiving section

Ceilingsurface

Liquid pipeGas pipe

Drain hose

Pipe cover

Drain panOutlet opening area

Drain hose connecting part

Pipecover

308

Susp

ensio

n bo

lt pi

tch

Drain hose

No gaps between the ceiling surface and grille

R66

CL

CL

0.04m2

13.549.7

2020

2626

5823

0

2

2

960 78

360

110

170

244

175

112

116

110

602548

58

(51.

6)18

0

1102

1200

414

34

15

58 18

158

R6

31

100

466.

5

466.

5

166.5

0

172.4

81.8

173166.5

Center of ceiling opening, suspension bolt pitch and grille are located in one position.

Air outlet

Ceiling surface Ceiling surface

Suspension bolt M10

Grille

414

Out

er s

ide

of g

rille

384

Cei

ling

open

ing

308

Susp

ensio

n bo

lt pitc

h38

38

175

180

or m

ore

54.51051 Suspension bolt pitch

1160 Ceiling opening

1200 Outer side of grille

Outlet

2020

54.5

1515

(Top)

(Front)(Right side)

(Top)

(Front)

cassette-way1Unit : mm Unit : mm

PLA-RP50BA PLA-RP60BA PLA-RP71BA

INDOOR UNIT

Ceiling hole

Branch duct hole

Indoor unit/Outdoor unit connecting terminal block Indoor power supplyterminal block(optional part)

Branch duct hole

Fresh air intake hole

Ceilin

g hole

Susp

ensio

n bolt

pitch

Suspension bolt pitch

Remote controller terminal block

(7.5)

(7.5)

605

+35

-

5

620

160

160

160

840

150

90 C D

840187.5

20~45 860~910 20~45

810

20~4

586

0~91

020

~45

24 160

950

Cut out hole

Cut out holeBurring hole pitch Burring hole

175

167

130

100

70

155

350

90 100 100 90

Detail connecting of branch duct

14- 2.8150

37728460 Drain pipe

Ceiling

Grille

Power supply wire,Indoor unit/Outdoor unit connecting wire entryControl wire entry

Keep approximately 10 to 15mm spacebetween unit ceiling and ceiling slab.

Suspension bolt M10 or W3/8

A17

+5 0

B35

190

156

105

140

50~7

0Suspension bolt lower edge

170

950

Refrigerant pipe

Refrigerant pipe

(liquid)

(gas)

Models BA C D

241 258

80

87

74

85 77

PLA-RP50BA

PLA-RP60BA

PLA-RP71BA

cassette-way4

35 36

Page 25: Wrap Yourself in Comfort and Quiet - Mitsubishi Electric VN · MXY SERIES (Cooling Only) MXZ SERIES (Heat Pump) EXTERNAL DIMEMSIONS PIPING INSTALLATIONS CITY MULTI CITY MULTI S SERIES

Unit : mm

SEZ-KD25VAL SEZ-KD35VAL SEZ-KD50VAL SEZ-KD60VAL SEZ-KD71VAL

24

20

16

900

700

500

9

7

5

1060

860

660LJH K

SEZ-KD71VALSEZ-KD60VALSEZ-KD50VALSEZ-KD35VAL

700 752 798 660 7 600

1198

998

AModelSEZ-KD25VAL

1152

952

B

1100

900

C

1060

860

D

11

9

E

1000

800

F

Notes:1. Use M10 bolts for suspension (purchase locally).2. Keep service space for maintenance at the bottom.3. This chart is based on the SEZ-KD50VAL, which has three fans.

SEZ-KD25VAL and SEZ-KD35VAL have two fans, and SEZ-KD60VAL and SEZ-KD71VAL have four fans.

4. If an inlet duct is used, remove the air filter supplied with the unit,and install a locally purchased filter on the suction side.

Airoutlet

Airinlet

Terminal block(Remote controller transmission line)

Drain pipe(Spontaneous draining)

Refrigerant pipingflare connection (gas)

Refrigerant pipingflare connection (liquid)

Terminal block(Indoor/outdoor connecting line)

Suspension bolt hole4-14X30 Slot

Air filter

Control box

2XE- 2.9

2X2- 2.9

L- 2.9

Knockout hole 27(Indoor/outdoor connecting line)

Knockout hole 27(Remote controller transmission line)

10

170

5715

20

100

100X

(E-1

)=F

30D

(Duc

t)

625 (Suspension bolt pitch) 90A

23B

(Sus

pens

ion

bolt

pitc

h)C

23 677700

2510

023

150

(Duc

t)

116 70

270

102

25 49

10

8810

010

0XJ=

K88

12

12 37 100

20 157.5

20H

200

37

INDOOR UNIT

Ceiling-concealedUnit : mm

MXY-2E20VA MXZ-2C52VA

5151

170.4

44

400

304

325

344.

5

17.5

40

22.3

550

280

10

800

500150

302.5

1323 285

51

251.

1

69

handle

Air in

Air out

Air in

2-10x21 Oval hole

Drain hole

Liquid pipe Gas pipeLiquid pipeGas pipe

B unit connection

A unit connection

OUTDOOR UNIT

460

317

900

Air out

900

HandleHandle

3574

200 200500

35 250 270

355

(Bol

t pitc

h)38

7

4027 16

1611

24

Drain holes

(Base bolt M10)

(Base bolt M10)2 U-shaped notched hole

2-12 x 36 Oval hole

Air in

Air in

B

A

32030 10

88

Gas pipe

Liquid pipe

D unit connection

E unit connection(MXZ-5C100VA)

C unit connectionB unit connectionA unit connection

23

597

132

405

45

Indoor and outdoorconnect wiring (35 x 53) hole

MXY-4A38VA MXZ-4C80VA MXZ-5C100VAOUTDOOR UNIT

MXY SERIES MXZ SERIES

(Bol

t Pitc

h)

4-10 x 21 Oval hole(Base bolt M10)

Air in

Air in

Air outDrain holes

31.3

12.3

18.3

171500169

63.2

360.

6

16.8

288233.1

17.7

17.7

396

30 330

66.3

840 30

710

299

360

240

200

Indoor and outdoor connect wiring 39 x 27 hole

27.1

23.1

45 225

84

440

Gas pipe

Liquid pipe

C unit connection

B unit connection

A unit connection

13

MXY-3A28VA MXZ-3C68VAOUTDOOR UNIT

MXY-4A28VA MXZ-4C71VA

Air in

Air in

Air out

(Base bolt M10)4-10 x 21 Oval hole

Drain holes (Bol

t Pitc

h)

171500

360.

6

18.3

12.3

16.8 31

.3

63.2 288233.1

169

396

17.7

17.7

Liquid pipe

330 1330

66.3Indoor and outdoor connect wiring 39 x 27 hole

27.1

23.1

440

45

315

84

299

360

710

840 30200

240

D unit connection

C unit connection

B unit connection

A unit connection

Gas pipe

OUTDOOR UNIT

37 38

Page 26: Wrap Yourself in Comfort and Quiet - Mitsubishi Electric VN · MXY SERIES (Cooling Only) MXZ SERIES (Heat Pump) EXTERNAL DIMEMSIONS PIPING INSTALLATIONS CITY MULTI CITY MULTI S SERIES

MXZ-6C120VA

(Foundation Bolt M10)2-12 x 36 Oval Hole

2-U Shaped Notched Hole(Foundation Bolt M10)

42 Drain Hole

Side Air Intake

AirDischarge

Rear AirIntake

(Bol

t Pitc

h)

387

48

450

2740

200500200

2416

355

1611

Handle

LIQ 6.35(1/4")FLAREGAS 12.7(1/2")FLAREUnit ALIQ

GAS

Unit BLIQGAS

Unit CLIQGAS

Unit DLIQGAS

GASLIQ Unit E

LIQ 6.35(1/4")FLAREGAS 9.52(3/8")FLARE

Unit FLIQGAS

532021

70

900

340

1070

548

ConnectingWire Hole(36 x 96)

730

34

125

515

4565

Handle

Unit : mm

OUTDOOR UNIT

20m

30m

20

30

Outdoor unit - Indoor unit (a,b)

Total length (a+b)

Outdoor unit - Indoor unit (a,b)

Total number (a+b)

Maximum Piping Length

Maximum Number of Bends

Outdoor unit - Indoor unit (a,b,c)

Total length (a+b+c)

Outdoor unit - Indoor unit (a,b,c)

Total number (a+b+c)

Maximum Piping Length

Maximum Number of Bends

MXY SERIES MXZ SERIES

25m

60m

25

60

MXY-3A28VA MXZ-3C68VA

MXY-2E20VA MXZ-2C52VA

a

b

c

Outdoorunit

Indoorunits

a

b

Outdoorunit

Indoorunits

Outdoor unit|

Indoor unit

15m

Outdoor unit|

Indoor unit

10m

Indoor unit|

Indoor unit

15m

*Outdoor unit installed lower

*Outdoor unit installed higher

Outdoor unit|

Indoor unit

15m

Outdoor unit|

Indoor unit

10m

Indoor unit|

Indoor unit

15m

*Outdoor unit installed lower

*Outdoor unit installed higher

Maximum height difference

Maximum height difference

Highest

Lowest

Piping Installation

39 40

Page 27: Wrap Yourself in Comfort and Quiet - Mitsubishi Electric VN · MXY SERIES (Cooling Only) MXZ SERIES (Heat Pump) EXTERNAL DIMEMSIONS PIPING INSTALLATIONS CITY MULTI CITY MULTI S SERIES

Maximum Piping Length

Maximum Number of Bends

Maximum Piping Length

Maximum Number of Bends

Maximum Piping Length

Maximum Number of Bends

25m

60m

25

60

b

c

Outdoorunit

25m

70m

25

70

25m

80m

25

80

MXY-4A38VA MXZ-4C80VA

b

c

Outdoorunit

e

Indoorunits

IndoorunitsMXZ-5C100VA

Outdoor unit - Indoor unit (a,b,c,d)

Total length (a+b+c+d)

Outdoor unit - Indoor unit (a,b,c,d)

Total number (a+b+c+d)

Outdoor unit - Indoor unit (a,b,c,d)

Total length (a+b+c+d)

Outdoor unit - Indoor unit (a,b,c,d)

Total number (a+b+c+d)

Outdoor unit - Indoor unit (a,b,c,d,e)

Total length (a+b+c+d+e)

Outdoor unit - Indoor unit (a,b,c,d,e)

Total number (a+b+c+d+e)

Maximum height difference

Maximum height difference

a

d

Outdoor unit|

Indoor unit

15m

Outdoor unit|

Indoor unit

10m

Indoor unit|

Indoor unit

15m

*Outdoor unit installed lower

*Outdoor unit installed higher

Outdoor unit|

Indoor unit

15m

Outdoor unit|

Indoor unit

10m

Indoor unit|

Indoor unit

15m

*Outdoor unit installed lower

*Outdoor unit installed higher

MXY-4A28VA MXZ-4C71VA

Lowest

Highest

a

d

Lowest

Highest

Maximum Piping Length

Maximum Number of Bends

25m

80m

25

80

b

c

Outdoorunit

f

eIndoorunitsMXZ-6C120VA

Outdoor unit - Indoor unit (a,b,c,d,e,f)

Total length (a+b+c+d+e+f)

Outdoor unit - Indoor unit (a,b,c,d,e,f)

Total number (a+b+c+d+e+f)

Maximum height difference

Outdoor unit|

Indoor unit

15m

Outdoor unit|

Indoor unit

10m

Indoor unit|

Indoor unit

15m

*Outdoor unit installed lower

*Outdoor unit installed higher

a

d

Lowest

Highest

41 42