WELDER PERFORMANCE QUALIFICATION TEST RECORD
( AWS D1.1 & 230/10/10/QA/PC/NA/0116)
Certificate No.: 047 Form No.: 583-STR-008
Type of Welder: Manual
Welder ID : W - 1056Using WPS No. 583-06 Date : 30.11.2011
The above mentioned welder is qualified for the following ranges.
Variables Record Actual Values Qualification Range
Used in Qualification
Process/Type [Table 4.12, Item (1)] SMAW SMAW
Electrode (single or multiple) [Table 4.12, Item (7)] Single Single
Current/Polarity DCEP DCEP
Position [Table 4.12, Item (3)] 3G (V) 3G (F,V)
Weld Progression [Table 4.12, Item (5)] Vertical Up Vertical Up
Backing (YES or NO) [Table 4.12, Item (6)] Without With or Without
Material/Spec.
Base Metal BS EN 10025 S275JR BS EN 10025 S275JR or Equivalent
Thickness: (Plate)
Groove 12 mm 3 - 24 mm
Fillet NA ALL
Thickness: (Pipe/tube)
Groove NA 3 - 24 mm (24" & above Dia.)
Fillet NA All Thickness for 24" & above Dia.
Diameter: (Pipe)
Groove NA Ø 24 inch & Above
Fillet NA Ø 24 inch & Above
Filler Metal (Table 4.12)
Spec. No. SFA 5.1 SFA 5.1
Class E 7018-1 E 7018-1
F-No. [Table 4.12, Item (2)] F4 F4
Gas/Flux Type (Table 4.12) NA NA
Other
VISUAL INSPECTION (4.8.1)
GUIDED BEND TEST RESULTS (4.30.5)
Type Result Type Result
NA
FILLET TEST RESULTS (4.30.2.3 and 4.30.4.1)
(Describe the location, nature, and size of any crack or tearing of the specimen.)
RADIOGRAPHIC TEST RESULTS (4.30.3.2)Film Identification Results RemarksNumber ACCEPTED NAWQT- 78
V.R. ANJANEYULU Test Number: RT/WQT- 54
Medgulf Const. Co CAEL Qatargas
Name
Welder Name: Niraj Kumar
Acceptable YES or NO: YES Report No.: VT/WQT-78
Appearance : ____________________NA_________ Fillet Size:______________NA__________________
Fracture Test Root Penetration:______ NA _________ Macroetch: _____________NA__________________
Interpreted by: Organization: Sievert Date: 30.11.2011
PHOTO
Signature
Date