WQT Format

4
WELDER PERFORMANCE QUALIFICATION TEST RECORD ( AWS D1.1 & 230/10/10/QA/PC/NA/0116) Certificate No.: 047 Form No.: 583-STR-008 Type of Welder Manual Welder ID : W - 1056 Using WPS No. 583-06 Date : 30.11.2011 The above mentioned welder is qualified for the following ranges. Variables Record Actual Values Qualification Range Used in Qualification Process/Type [Table 4.12, Item (1)] SMAW SMAW Electrode (single or multiple) [Table 4.12, Item (7) Single Single Current/Polarity DCEP DCEP Position [Table 4.12, Item (3)] 3G (V) 3G (F,V) Weld Progression [Table 4.12, Item (5)] Vertical Up Vertical Up Backing (YES or NO) [Table 4.12, Item (6)] Without With or Without Material/Spec. Base Metal BS EN 10025 S275JR BS EN 10025 S275JR or Equival Thickness: (Plate) Groove 12 mm 3 - 24 mm Fillet NA ALL Thickness: (Pipe/tube) Groove NA 3 - 24 mm (24" & above Dia Fillet NA All Thickness for 24" & above D Diameter: (Pipe) Groove NA Ø 24 inch & Above Fillet NA Ø 24 inch & Above Filler Metal (Table 4.12) Spec. No. SFA 5.1 SFA 5.1 Class E 7018-1 E 7018-1 F-No. [Table 4.12, Item (2)] F4 F4 Gas/Flux Type (Table 4.12) NA NA Other VISUAL INSPECTION (4.8.1) GUIDED BEND TEST RESULTS (4.30.5) Type Result Type Result NA FILLET TEST RESULTS (4.30.2.3 and 4.30.4.1) (Describe the location, nature, and size of any crack or tearing of the specimen.) RADIOGRAPHIC TEST RESULTS (4.30.3.2) Film Identificati Results Remarks Number ACCEPTED NA WQT- 78 V.R. ANJANEYULU Test Number:RT/WQT- 54 Medgulf Const. Co CAEL Qatargas Name Welder Name: Niraj Kumar Acceptable YES or NO: YES Report No.: VT/WQT-78 Appearance : ____________________NA_________ Fillet Size:______________NA__________________ Fracture Test Root Penetration:______ NA _________ Macroetch: _____________NA__________________ Interpreted by Organization: Sievert Date: 30.11.2011 PHOTO

Transcript of WQT Format

Page 1: WQT Format

WELDER PERFORMANCE QUALIFICATION TEST RECORD

( AWS D1.1 & 230/10/10/QA/PC/NA/0116)

Certificate No.: 047 Form No.: 583-STR-008

Type of Welder: Manual

Welder ID : W - 1056Using WPS No. 583-06 Date : 30.11.2011

The above mentioned welder is qualified for the following ranges.

Variables Record Actual Values Qualification Range

Used in Qualification

Process/Type [Table 4.12, Item (1)] SMAW SMAW

Electrode (single or multiple) [Table 4.12, Item (7)] Single Single

Current/Polarity DCEP DCEP

Position [Table 4.12, Item (3)] 3G (V) 3G (F,V)

Weld Progression [Table 4.12, Item (5)] Vertical Up Vertical Up

Backing (YES or NO) [Table 4.12, Item (6)] Without With or Without

Material/Spec.

Base Metal BS EN 10025 S275JR BS EN 10025 S275JR or Equivalent

Thickness: (Plate)

Groove 12 mm 3 - 24 mm

Fillet NA ALL

Thickness: (Pipe/tube)

Groove NA 3 - 24 mm (24" & above Dia.)

Fillet NA All Thickness for 24" & above Dia.

Diameter: (Pipe)

Groove NA Ø 24 inch & Above

Fillet NA Ø 24 inch & Above

Filler Metal (Table 4.12)

Spec. No. SFA 5.1 SFA 5.1

Class E 7018-1 E 7018-1

F-No. [Table 4.12, Item (2)] F4 F4

Gas/Flux Type (Table 4.12) NA NA

Other

VISUAL INSPECTION (4.8.1)

GUIDED BEND TEST RESULTS (4.30.5)

Type Result Type Result

NA

FILLET TEST RESULTS (4.30.2.3 and 4.30.4.1)

(Describe the location, nature, and size of any crack or tearing of the specimen.)

RADIOGRAPHIC TEST RESULTS (4.30.3.2)Film Identification Results RemarksNumber ACCEPTED NAWQT- 78

V.R. ANJANEYULU Test Number: RT/WQT- 54

Medgulf Const. Co CAEL Qatargas

Name

Welder Name: Niraj Kumar

Acceptable YES or NO: YES Report No.: VT/WQT-78

Appearance : ____________________NA_________ Fillet Size:______________NA__________________

Fracture Test Root Penetration:______ NA _________ Macroetch: _____________NA__________________

Interpreted by: Organization: Sievert Date: 30.11.2011

PHOTO

Page 2: WQT Format

Signature

Date