WP7 Validation of baseline - Grakom · Application –Expected energy reductions •40.000 GJ of...
Transcript of WP7 Validation of baseline - Grakom · Application –Expected energy reductions •40.000 GJ of...
![Page 1: WP7 Validation of baseline - Grakom · Application –Expected energy reductions •40.000 GJ of yearly potential energy savings per 100 SMEs during the project lifetime •880 ton](https://reader034.fdocuments.in/reader034/viewer/2022050223/5f6881c80f150a56747400a2/html5/thumbnails/1.jpg)
WP7 Validation of baseline- Grakom
Copenhagen
26-27 September 2016
![Page 2: WP7 Validation of baseline - Grakom · Application –Expected energy reductions •40.000 GJ of yearly potential energy savings per 100 SMEs during the project lifetime •880 ton](https://reader034.fdocuments.in/reader034/viewer/2022050223/5f6881c80f150a56747400a2/html5/thumbnails/2.jpg)
Application – Expected energy reductions
• 40.000 GJ of yearly potential energy savings per 100 SMEs during the project lifetime
• 880 ton CO2 potential emission reduction each year per 100 SMEs during the project lifetime
• 915.000 € of potential decreasing yearly energy costs per 100 SMEs during the project lifetime
![Page 3: WP7 Validation of baseline - Grakom · Application –Expected energy reductions •40.000 GJ of yearly potential energy savings per 100 SMEs during the project lifetime •880 ton](https://reader034.fdocuments.in/reader034/viewer/2022050223/5f6881c80f150a56747400a2/html5/thumbnails/3.jpg)
WP2: Energy diagnosis - updating baseline
• WP2 summary: Only common indicator for baseline definition available from EEEI and ClimateCalc:
𝐵𝑎𝑠𝑒𝑙𝑖𝑛𝑒 (𝐾𝑃𝐼) =𝑇𝑜𝑡𝑎𝑙 𝑒𝑛𝑒𝑟𝑔𝑦 [𝐺𝐽]
𝑃𝑎𝑝𝑒𝑟 𝑐𝑜𝑛𝑠𝑢𝑚𝑒𝑑 𝑡𝑜𝑛 −𝑃𝑎𝑝𝑒𝑟 𝑤𝑎𝑠𝑡𝑒 [𝑡𝑜𝑛]
• Problems with the indicator:• Summarized energy for process and heating
• Based on weight where the thickness varies
• Based on paper waste which varies with the products and the quality
![Page 4: WP7 Validation of baseline - Grakom · Application –Expected energy reductions •40.000 GJ of yearly potential energy savings per 100 SMEs during the project lifetime •880 ton](https://reader034.fdocuments.in/reader034/viewer/2022050223/5f6881c80f150a56747400a2/html5/thumbnails/4.jpg)
WP2: Energy diagnosis - updating baseline
• The experience with the KPI must be taken into consideration in WP3: Indicators.
• WP2 summary: The baseline must be updated with data from the 100 companies after WP6.
0
1
2
3
4
5
6
7
Germany Denmark TheNetherlands
Spain The CzechRepublic
GJ/ton
Average energyconsumption
Average of allcountries
Standarddeviation (+)
Standarddeviation (-)
![Page 5: WP7 Validation of baseline - Grakom · Application –Expected energy reductions •40.000 GJ of yearly potential energy savings per 100 SMEs during the project lifetime •880 ton](https://reader034.fdocuments.in/reader034/viewer/2022050223/5f6881c80f150a56747400a2/html5/thumbnails/5.jpg)
Total energy consumption in EMSPI SME’s
![Page 6: WP7 Validation of baseline - Grakom · Application –Expected energy reductions •40.000 GJ of yearly potential energy savings per 100 SMEs during the project lifetime •880 ton](https://reader034.fdocuments.in/reader034/viewer/2022050223/5f6881c80f150a56747400a2/html5/thumbnails/6.jpg)
Total energy consumption in EMSPI SME’s
Number of companies Total CompleteDE 15 14ES 17 16DK 19 19CZ 9 7NL 19 15Total 79 71
ChangesTotal energy 2013-2015 GJ -46.405Total energy 2013-2015 % -7%Total production 2013-2015 ton 4.103Total production 2013-2015 % 1%
![Page 7: WP7 Validation of baseline - Grakom · Application –Expected energy reductions •40.000 GJ of yearly potential energy savings per 100 SMEs during the project lifetime •880 ton](https://reader034.fdocuments.in/reader034/viewer/2022050223/5f6881c80f150a56747400a2/html5/thumbnails/7.jpg)
Baseline - KPI analysis
![Page 8: WP7 Validation of baseline - Grakom · Application –Expected energy reductions •40.000 GJ of yearly potential energy savings per 100 SMEs during the project lifetime •880 ton](https://reader034.fdocuments.in/reader034/viewer/2022050223/5f6881c80f150a56747400a2/html5/thumbnails/8.jpg)
Baseline - KPI analysis
![Page 9: WP7 Validation of baseline - Grakom · Application –Expected energy reductions •40.000 GJ of yearly potential energy savings per 100 SMEs during the project lifetime •880 ton](https://reader034.fdocuments.in/reader034/viewer/2022050223/5f6881c80f150a56747400a2/html5/thumbnails/9.jpg)
Baseline - KPI analysis
![Page 10: WP7 Validation of baseline - Grakom · Application –Expected energy reductions •40.000 GJ of yearly potential energy savings per 100 SMEs during the project lifetime •880 ton](https://reader034.fdocuments.in/reader034/viewer/2022050223/5f6881c80f150a56747400a2/html5/thumbnails/10.jpg)
Baseline - KPI analysis
• The KPI varies with the type of companies.
• Data quality for WP2 baseline is an issues.
• The baseline must be calibrated based on data for the participating companies with 2013 as starting point.
• The baseline should be changed to:
𝐵𝑎𝑠𝑒𝑙𝑖𝑛𝑒 (𝐾𝑃𝐼) =𝑇𝑜𝑡𝑎𝑙 𝑒𝑛𝑒𝑟𝑔𝑦 [𝐺𝐽]
𝑃𝑎𝑝𝑒𝑟 𝑐𝑜𝑛𝑠𝑢𝑚𝑒𝑑 𝑡𝑜𝑛
![Page 11: WP7 Validation of baseline - Grakom · Application –Expected energy reductions •40.000 GJ of yearly potential energy savings per 100 SMEs during the project lifetime •880 ton](https://reader034.fdocuments.in/reader034/viewer/2022050223/5f6881c80f150a56747400a2/html5/thumbnails/11.jpg)
Energy savings - normalised and weighted
• Data are normalised to the paper consumption of 2013
• KPI is weighted for all companies.
Total emission Total reduction
2013 2014 2015 2013-2014 2013-2015Total GJ 666.933 653.128 642.272 -13.804 -24.661
![Page 12: WP7 Validation of baseline - Grakom · Application –Expected energy reductions •40.000 GJ of yearly potential energy savings per 100 SMEs during the project lifetime •880 ton](https://reader034.fdocuments.in/reader034/viewer/2022050223/5f6881c80f150a56747400a2/html5/thumbnails/12.jpg)
Validation of GHG and economic savings
• How do we do this?