Wiring Schematic Diagram - Panasonic Business … Schematic Diagram Wire type and length The DECT...

1
MAIN MONITOR DOOR STATION 1 ELECTRIC LOCK DOOR STATION 2 NP NP NP NP 24 V DC 12 V AC/DC NP AC A D C B Rear view Rear view Power Supply NP Power Supply Power Supply Power Supply NP NP Rear view D E ELECTRIC LOCK ELECTRIC LOCK ELECTRIC LOCK 12 V AC/DC 12 V AC/DC 12 V AC/DC POWER SUPPLY UNIT 220-240 V AC Bedroom Den Living Room Kitchen Room 1 Room 2 Room 3 Room 4 VL-PS241 Electric lock Electric lock Garage Pool < 2 Wire > Bedroom Den Living Room Kitchen Room 1 Room 2 Room 3 Room 4 VL-PS241 Garage Pool 2 Wire > < < > + + + + 100m 100m 100m 100m 100m 100m Power Supply Unit Power Supply Unit Power Supply Unit Power Supply Unit Power Supply Unit * Up to 2 repeaters can be used. System Configuration Expanded system example VL-SWD501 VL-WD812 VL-FKD2 VL-V554 VL-WD613 Up to 5 Video Intercom System DECT Wireless Sensor Camera DECT Wireless Repeater Door Station DECT Wireless Sub Monitor VL-SWD501 DECT Repeater Wiring Schematic Diagram Wire type and length The DECT Repeater can also be connected to increase usage area. Using one repeater Using two repeaters connected together A single repeater cannot be used to send signals to both sub monitors and cameras. Wiring run Wire type Diameter Length (Max.) φ 0.65 mm φ 1.0 mm φ 0.5 mm φ 1.2 mm - φ 2.0 mm (17 AWG - 12 AWG) φ 0.5 mm - φ 1.2 mm (24 AWG - 17 AWG) φ 0.5 mm - φ 0.8 mm (24 AWG - 20 AWG) 22 AWG 18 AWG CAT 5 No requirement According to specification of connected device. According to specification of connected device. Must be no longer than 20 m. Main monitor – Connection device for option output (A contact) Main monitor – Door station Main monitor – Power supply unit Power supply unit – AC power source Door station – Electric lock Wireless sensor camera – Power supply unit Power supply unit (for wireless sensor camera) – AC power source Wireless sensor camera – External sensor φ 0.65 mm φ 1.0 mm φ 0.65 mm φ 1.0 mm 22 AWG 22 AWG 18 AWG 18 AWG φ 1.2 mm - φ 2.0 mm (17 AWG - 12 AWG) φ 0.5 mm - φ 1.2 mm (24 AWG - 17 AWG) 100 m 130 m 50 m 10 m 20 m According to specification of connected device. 50 m 100 m No requirement A D C B E - - - *1 *2 *2 *1 Type: Single-pair cable with outer sheath (jacket) Conductor: Copper solid • A certified power supply wiring has to be used with this equipment. The relevant national installation and/or equipment regulations shall be considered. A certified power supply wiring not lighter than ordinary polyvinyl chloride flexible wiring according to IEC 60227 shall be used. *2 When using an electric lock or a connection device for option output (A contact), select a device that meets the following guidelines: • Electric lock connection terminal (S1/S2, S3/S4): N/O dry closure contact 12 V AC/DC, less than 1 A • Connection device for option output (A contact) terminal (OUT1/OUT2): 24 V AC/DC, less than 0.3 A (minimum contact: 5 V DC 1 mA) Model No. * Signal range differs depending on factors such as the structure of rooms or the types of walls used. Connection device for option output (A contact) (Electric vehicle gate lock) (Electric vehicle gate lock) (Electric door lock) (Electric door lock) *1 *2 *1 *2 NP: Non-polarised *1 Make sure to only connect electric vehicle gate locks to the S3/S4 terminals of the door stations. (VL-SWD501EX, VL-SWD501FX models only) *2 Make sure to only connect electric door locks to the S1/S2 terminals of the door stations. Video Intercom System with Wireless Monitor (DECT) A single repeater can be used to send signals to either multiple sub monitors or cameras. * Only for distribution in Europe, Middle East, Asia & Oceania Up to 2 Up to 4

Transcript of Wiring Schematic Diagram - Panasonic Business … Schematic Diagram Wire type and length The DECT...

Page 1: Wiring Schematic Diagram - Panasonic Business … Schematic Diagram Wire type and length The DECT Repeater can also be connected to increase usage area. ・ Using one repeater ・

MAIN MONITOR

DOOR STATION 1

ELECTRIC LOCK

DOOR STATION 2NP

NP

NP

NP

24 V DC

12 V AC/DC

NP

AC

A

D

C

B

Rear view

Rear view

PowerSupply

NP

PowerSupply

PowerSupply

PowerSupply

NP

NP

Rear view

D

E

ELECTRIC LOCK

ELECTRIC LOCK

ELECTRIC LOCK 12 V AC/DC

12 V AC/DC

12 V AC/DC

POWER SUPPLY UNIT

220-240 V AC

Bedroom

DenLiving Room Kitchen

Room 1 Room 2

Room 3 Room 4

VL-PS241

Electric lockElectric lock

Garage

Pool

< 2 Wire >

Bedroom

DenLiving Room Kitchen

Room 1 Room 2

Room 3 Room 4

VL-PS241

Garage

Pool

2 Wire >< < >

+ ++ +

100m

100m 100m

100m 100m 100m

PowerSupply Unit

PowerSupply Unit

PowerSupply Unit Power

Supply Unit

PowerSupply Unit

* Up to 2 repeaters can be used.

System ConfigurationExpanded system example

VL-SWD501 VL-WD812 VL-FKD2VL-V554 VL-WD613

Up to5

Video Intercom SystemDECT WirelessSensor Camera

DECT WirelessRepeaterDoor Station

DECT WirelessSub Monitor

VL-SWD501

DECT Repeater

Wiring Schematic Diagram

Wire type and lengthThe DECT Repeater can also be connected to increase usage area.

・ Using one repeater

・ Using two repeaters connected togetherA single repeater cannot be used to send signals to both sub monitors and cameras.

・ Wiring run Wire typeDiameter Length (Max.)

φ 0.65 mmφ 1.0 mmφ 0.5 mm

φ 1.2 mm - φ 2.0 mm (17 AWG - 12 AWG)φ 0.5 mm - φ 1.2 mm (24 AWG - 17 AWG)

φ 0.5 mm - φ 0.8 mm (24 AWG - 20 AWG)

22 AWG18 AWGCAT 5

No requirementAccording to specification of connected device.

According to specification of connected device. Must be no longer than 20 m.

Main monitor – Connection device for option output (A contact)

Main monitor – Door station

Main monitor – Power supply unit

Power supply unit – AC power sourceDoor station – Electric lock

Wireless sensor camera – Power supply unit

Power supply unit (for wireless sensor camera) – AC power sourceWireless sensor camera – External sensor

φ 0.65 mmφ 1.0 mm

φ 0.65 mmφ 1.0 mm

22 AWG

22 AWG

18 AWG

18 AWG

φ 1.2 mm - φ 2.0 mm (17 AWG - 12 AWG)

φ 0.5 mm - φ 1.2 mm (24 AWG - 17 AWG)

100 m130 m50 m10 m20 m

According to specification of connected device.

50 m100 m

No requirement

A

DC

B

E

-

-

-

*1

*2

*2

*1 Type: Single-pair cable with outer sheath (jacket) Conductor: Copper solid • A certified power supply wiring has to be used with this equipment. The relevant national installation and/or equipment regulations shall be considered. A certified power supply wiring not lighter than ordinary polyvinyl chloride flexible wiring according to IEC 60227 shall be used.*2 When using an electric lock or a connection device for option output (A contact), select a device that meets the following guidelines: • Electric lock connection terminal (S1/S2, S3/S4): N/O dry closure contact 12 V AC/DC, less than 1 A • Connection device for option output (A contact) terminal (OUT1/OUT2): 24 V AC/DC, less than 0.3 A (minimum contact: 5 V DC 1 mA)

Model No.

* Signal range differs depending on factors such as the structure of rooms or the types of walls used.

Connection device for option output (A contact)

(Electric vehicle gate lock)

(Electric vehicle gate lock)

(Electric door lock)

(Electric door lock)

*1

*2

*1

*2

NP: Non-polarised *1 Make sure to only connect electric vehicle gate locks to the S3/S4 terminals of the door stations. (VL-SWD501EX, VL-SWD501FX models only)*2 Make sure to only connect electric door locks to the S1/S2 terminals of the door stations.

Video Intercom System with Wireless Monitor (DECT)

A single repeater can be used tosend signals to either multiple submonitors or cameras.

* Only for distribution in Europe, Middle East, Asia & Oceania

Up to2

Up to4