12
Wireless Sensors for the measurement of dissolved oxygen in aquaculture plants Agenda entire System ADUM5241 O2-sensor SX8723 ATtiny2313 Comunication Example Questions End

Transcript of Wireless Sensors for the measurement of dissolved oxygen ...€¦ · Wireless Sensors for the...

Page 1: Wireless Sensors for the measurement of dissolved oxygen ...€¦ · Wireless Sensors for the measurement of dissolved oxygen in aquaculture plants Agenda entire System ADUM5241 O2-sensor

Wireless Sensors forthe measurement of dissolved oxygen in aquaculture plants

Agenda entire System ADUM5241 O2-sensor SX8723 ATtiny2313 Comunication Example Questions End

Page 2: Wireless Sensors for the measurement of dissolved oxygen ...€¦ · Wireless Sensors for the measurement of dissolved oxygen in aquaculture plants Agenda entire System ADUM5241 O2-sensor

AgendaAgenda•• thethe entireentire systemsystem (block (block diagramdiagram))•• modulsmoduls of of thethe systemsystem

–– GalvanicGalvanic seperationseperation–– SensorsignlasSensorsignlas convertionconvertion–– TransmitingTransmiting

•• typicaltypical AplicationAplication–– ExampleExample AquacultureAquaculture plantplant

•• questionsquestions

Agenda entire System ADUM5241 O2-sensor SX8723 ATtiny2313 Comunication Example Questions End

Page 3: Wireless Sensors for the measurement of dissolved oxygen ...€¦ · Wireless Sensors for the measurement of dissolved oxygen in aquaculture plants Agenda entire System ADUM5241 O2-sensor

The entire system

Agenda entire System ADUM5241 O2-sensor SX8723 ATtiny2313 Comunication Example Questions End

Page 4: Wireless Sensors for the measurement of dissolved oxygen ...€¦ · Wireless Sensors for the measurement of dissolved oxygen in aquaculture plants Agenda entire System ADUM5241 O2-sensor

The entire system

measurementcommunicationGalvanicseperation

ADUM5241

ADUM5241 (Analog Devics)

dual-channel digital isolatorsdc-to-dc converter integratedlow-power consumpation

6 mA (DC-to-DC Converter disabled)max. 140 mA (DC-to-DC Converter enabled)

two independent isolation channelsup to 1Mbps

origin: www.analog.com

Agenda entire System ADUM5241 O2-sensor SX8723 ATtiny2313 Comunication Example Questions End

Page 5: Wireless Sensors for the measurement of dissolved oxygen ...€¦ · Wireless Sensors for the measurement of dissolved oxygen in aquaculture plants Agenda entire System ADUM5241 O2-sensor

The entire system

measurementcommunicationGalvanicseperation

ADUM5241RS232 RS232

sensorsignalssignal converting

Agenda entire System ADUM5241 O2-sensor SX8723 ATtiny2313 Comunication Example Questions End

Page 6: Wireless Sensors for the measurement of dissolved oxygen ...€¦ · Wireless Sensors for the measurement of dissolved oxygen in aquaculture plants Agenda entire System ADUM5241 O2-sensor

The entire system

measurementcommunicationGalvanicseperation

ADUM5241RS232 RS232

sensorsignalssignal converting

temperatur sensorO2-sensor includes aNTC for temperaturmeasurement

O2-sensor

Analog voltagefrom 0 mV to 20 mV

O2-sensor

Temperatur sensor

Agenda entire System ADUM5241 O2-sensor SX8723 ATtiny2313 Comunication Example Questions End

Page 7: Wireless Sensors for the measurement of dissolved oxygen ...€¦ · Wireless Sensors for the measurement of dissolved oxygen in aquaculture plants Agenda entire System ADUM5241 O2-sensor

The entire system

measurementcommunicationGalvanicseperation

ADUM5241RS232 RS232

sensorsignalssignal converting

O2-sensor

Temperatur sensor

SX8723

SX8723 (Semtech)

• Up to 16-bit differential data acquisition• Programmable gain (1/12 to 1000)• internal voltage reference• consumpation 850 µA• I²C interface

origin: www.semtech.com

Agenda entire System ADUM5241 O2-sensor SX8723 ATtiny2313 Comunication Example Questions End

Page 8: Wireless Sensors for the measurement of dissolved oxygen ...€¦ · Wireless Sensors for the measurement of dissolved oxygen in aquaculture plants Agenda entire System ADUM5241 O2-sensor

The entire system

measurementcommunicationGalvanicseperation

ADUM5241RS232 RS232

sensorsignalssignal converting

O2-sensor

Temperatur sensor

SX8723ATtiny2313

ATtiny2313 (Atmel)

• consumpation 230 µA• internal Calibrated Oscillator• full Duplex USART• I²C-Intervace

I²C

• only two wires required• SDA (data)• SCL (clock)

• I²C speed up to 400kHz

I²C

Agenda entire System ADUM5241 O2-sensor SX8723 ATtiny2313 Comunication Example Questions End

Page 9: Wireless Sensors for the measurement of dissolved oxygen ...€¦ · Wireless Sensors for the measurement of dissolved oxygen in aquaculture plants Agenda entire System ADUM5241 O2-sensor

The entire system

measurementcommunicationGalvanicseperation

ADUM5241RS232 RS232

sensorsignalssignal converting

O2-sensor

Temperatur sensor

SX8723ATtiny2313

I²C

ZigBee(ZigBit MNZB-24-A2)

ZigBit MNZB-24-A2 (Meshnetics)

• shortrange (up to 100 m)• low-power consumpation (20 mA TX/RX)• tree, star, mesh network• High sensitivity (104 dB Link Budget)• 250 kbps On-Air Data Rate • 16 Channels (5 MHz Channel Spacing)• 16-bit Adressing

Agenda entire System ADUM5241 O2-sensor SX8723 ATtiny2313 Comunication Example Questions End

Page 10: Wireless Sensors for the measurement of dissolved oxygen ...€¦ · Wireless Sensors for the measurement of dissolved oxygen in aquaculture plants Agenda entire System ADUM5241 O2-sensor

Coordinator(Control Room)

Sensor node

Router node

AquacultureAquaculture plantplant

Agenda entire System ADUM5241 O2-sensor SX8723 ATtiny2313 Comunication Example Questions End

Page 11: Wireless Sensors for the measurement of dissolved oxygen ...€¦ · Wireless Sensors for the measurement of dissolved oxygen in aquaculture plants Agenda entire System ADUM5241 O2-sensor

Are Are therethere anyany questionsquestions youyouwantwant to to askask??

Agenda entire System ADUM5241 O2-sensor SX8723 ATtiny2313 Comunication Example Questions End

Page 12: Wireless Sensors for the measurement of dissolved oxygen ...€¦ · Wireless Sensors for the measurement of dissolved oxygen in aquaculture plants Agenda entire System ADUM5241 O2-sensor

ThanksThanks to:to:•• Dr. H. Dr. H. DispertDispert•• Dr. T. Dr. T. KnutzKnutz•• degreeddegreed engineerengineer C. C. WitthandtWitthandt

ThankThank youyou forfor youryour attentionattentionAgenda entire System ADUM5241 O2-sensor SX8723 ATtiny2313 Comunication Example Questions End