Wire Joints - Nylon Insulated · strain common in most elec-trical installations. ... two-way...
Transcript of Wire Joints - Nylon Insulated · strain common in most elec-trical installations. ... two-way...
Sta-KonWire Joints - Nylon Insulated
one piecenylon self-insulated
Installing tool - WT2000,WT2130A(RC&RP)
two piecenylon insulator
Installing tool -WT161M
one piecenon-insulatedInstalling tool -
WT161M
Sta-Kon wire joints come in one-piece nylon,self-insulated and non-insulated, and a two-piece nylon insulator. Tool applied.
U.L. Listed E9809Items on this page sold in multiples of unit packages only.
Installation Procedure for "PT" Connectors
%\ Crimp on Wire Joints - Tool Applied
^
D
3}
Cat.No.
RB44RB4RC55RC6RP12
RP7
, PT66MPT6MPT60M
, PT70PT70MPT80
Pkg.Qty.
1001000so5001001000
100in100
20020050
Win Range
Mln.
2*18
4*18
3*14
2*18
2114
2*14MM2*16
Max.
. 2*16
2*12 : c';.:£
4*12
3*12 combinationInsulator only
3*12 Connector only
3*12
r\.::; • ' 4*124*10
Dimensions
A
,31
.43
.53
.50
.31
.29
.31
.35
B
M
x ..::,:,.
. ..t.08 . . : . : , < -
.93
.37
.34
•37.62
Wt./Lbs.Per
1000
2
33
4
2
2
2
26
., Twist wires, insert through? serrated barrel of wire joint.
(PT60M, PT70, PT70M, PT80).
Crimp and trim off excess wirewith WT161M hand tool.
Screw PT6 insulator firmlyonto
PT160M barrel.
ThomasiBetts
42 O 2000 Thomas & Belts Corporation. Specifications are subject to change without notice. WWW.tnb.COm
Sta-KonTerminals
Why Sta-Kon Terminals Are Better - continued
Selective Annealing
•DeepInternalSerrations
• Flat bottom box• Electro-tin plating• Center reinforced
spring detent lorminimum insertionforce
• Compound SpringRails providepositive contactafter repeatedinsertions
Because of the mechanical strength ofcopper, an installer can experiencefatigue associated with repeated instal-lations. For this reason Thomas & Bettsputs our terminals through one morestep called selective annealing. Thisprocess leaves the barrel soft enoughto crimp and form around the wire.However, we "cold form" the tongueduring the manufacturing process so it
remains strong. This is done so thetongue can withstand repeated
bends and bolt tighteningstrain common in most elec-
trical installations. Manycompetitors attempt toaccomplish similar goalsby removing valuablematerial or using a softer
copper which has lowerconductivity. This increases
electrical resistance as well as theodds for shorting and downtime.
Anti-Rotational TonguesThis is a unique feature to the Thomas& Betts ring tongue terminal. Thisdesign prevents terminal shorting bykeeping the terminal secure in the ter-minal block. The installer can place agreater number of terminals closertogether without worry.
Proper IdentificationWe identify all terminals with Thomas &Betts initials, T & B. We also indicatewire and stud sizes. These markingsare clearly visible on the surface of thetongue, taking any guesswork out ofreplacing or reordering additionalparts. Our superior bright plating alsoassists in visibility.
All Sta-Kon* Terminals areDebarred and DegreasedTo insure a Sta-Kon® terminal is proper-ly plated and insulated, all our parts areput through a process which cleansand smooths the terminal of any manu-facturing by-products, mainly grease,oils and sharp edges. Many competitiveproducts do not put their productthrough such rigorous finishing.
Platings/FinishElectroplated-Tin is standard. All othersrequire minimum order quantities andare generally not stocked. Alternativeplatings as follows: Gold, Silver, Tin-alloys, Nickel, etc.The following finishes are available onmost one-piece Sta-Kon® terminals:
Finish
Gold Plate
Nickel Plate
Plain FinishSilver Plate
Tin Plate
Suffix
GP
NP
PF
SP
TP
Spec.
MIL-G-45204Type II, Grade B,C, D, Class OQQ-N-290 Class 2,Grade GNoneMIL-T-16366Typelor II, 400° F, 204 ° C
MIL-T- 10727 Type 1
To order add the indicated suffix to theregular catalog number.
Underwriters LaboratoriesListingSta-Kon® Rings, Fork, and LockingForks are tested and listed to U.L486A, two-way splices to U.L. 486C,disconnects to U.L. 310 and all appli-cable products to CSA 22.2.
ThomasiBetts
O 2000 Thomas & Betts Corporation Specifications are subject to change without notice. WWW.tnb.COm
Sta-KonTerminals
Sta-Kon* Ring, Fork & Locking Fork
ERG-2001
• Complete line of installing tools engineered to match tool with terminal.• First to gain military approval for pressure connections ... many styles available for
military applications.• Sta-Kon® products exceed test specification requirements of military, U.L. and CSA.• TEFZEL® & Nylon Terminals provided with extra metal sleeve to grip insulation.• Vinyl insulated and bare Sta-Kon® terminals feature brazed seam wire barrels which
can be crimped at any place on the barrel circumference.
Sta-Kon* Disconnects• Internal barrel serrations and long barrel provide for maximum tensile strength.• Complete line of installing tools, engineered to match tool with terminal.• Funnel entry insulators allow for easier inserting of wire into barrel.• Color-coded for easy installation.
The Shure Stake" Tools are Matched to TerminalsThe Shure Stake" mechanism prevents the dies from releasing the terminal untilthe proper compression has been completed. With this method, an operatorachieves a reliable crimp everytime. Thomas & Setts' tooling techniques correctlymatch tools, wire size and terminal to produce optimum mechanical and electricalperformance.
Sta-Korf Technical Data
Terminals & SplicesInsulation RatingNylonVinylTEFZEL"" 1000V fixture or signDisconnects
U.L. 94Flammability
V-2v-ov-o
Voltage600V**600 V"600V"
300V
Temperature705°CW5"C150°C
105°C
The Sta-Kon* Terminal Numbering SystemDistributor Package 100/50Bulk "O.E.M." Packaged 1000/500
Common to Both PackagesLetter A denotes 22- 18AWG wire rangeLetter B denotes 16-14 AWG wire rangeLetter C denotes 12-10 AWG wire rangeLetter R preceding the above letters indicates the terminal is insulatedNo letter R... no insulation ...no exception!
Distributor PackagedPart numbers are very descriptive indicating insulation and type, stud size, tonguestyle and the largest maximum wire that can be put inside.• If the letter R precedes the number the part is nylon insulated - RA18-6• If the letter R follows the number the part is vinyl insulated - 14RB-8
EXAMPLE: 10RC-8F
C-Indicates 12-10 AWG10RC-Vinyl Insulated8 - Indicates stud sizeF - means a fork tongue terminalFL-would indicate locking lork
Telzer is a registered trademark ot DuPont.
EXAMPLE: 2RA18X
2 - Indicates a 2 way or butt style connectorX - means expanded insulation.
ThomasiBetts
© 2000 Thomas & Belts Corporation. Specifications are subject to change without notice. WWW.tnb.COtTI
Color-KeyedColor-Keyed® Connectors
Order From
Catalog No.. Qty..(For 54100, 54200, 54800 & 54900 Series Copper Lugs Only)
Design Controls and RequirementsAll "MADE-UP" catalog numbers start with a standard or basic catalog number and are followed by the customer required extra
features: tongue shape, bolt hole size, distance between bolt holes, stacking, plating and inspection hole (peep hole). A codeletter or a number has been assigned to each extra feature. See CODE TABLE.
NOTES: 1) Lack of any of the extra features on the "MADE-UP" catalog number means that the standard Cat. No. features areprevalent.
2) If either bolt hole size or distance between bolt holes needs to be changed from standard Cat. No., both code num-bers will appear on the "MADE-UP" Cat. No. (See example below)
Cat. No. 54212UB0416BSP
54212 UB 04 16
2 hole4/0 cu. lug
basic cat. no.
Tongue Shape
Type Code
45° UF90° UB
Blank BT(No Bolt Hole)
Bolt Holes
Size
18#10Vf5VWVf%"IffW1"
.020
.173
.204
.281
.344
.406
.531
.656
.812
.937
1.062
Code
02030405060810121416
90°bend
1/4" V'holebolt hole spacing
CODE TABLEBolt
Hole Centers
Distance .015
VfWW7/8'
rr/s"w1 ya-
rn"
1%"1*
'17/8"
•2"
Code
08101214161820222426283032
Stacking Fin'?h ,(Plating)
Type Code Type 1 Code
Top T" Silver Plate SPBottom B Lead Plate LP
Nickel Plate NPPlain Finish PFNotQTPifsuffix otherthan - PF or
standardtin plate
bottomstack
Inspection Hole Inspection Hole(Long Barrel) (Short Barrel)
I.D. Code I.D. Code
Peephole PH Blind End BE
" These bolt centers not available lor bolt holes larger than'" Not required for 45° & 90° Top Stacking.
Cable
D«3
D*2
D2/0
CodeQWeldQ
D*6
n#iD3/0
D#4
D voCM/o
n 250 MCM & up (Code Only)
Barrel LengthInspection Hole
f jYesnspection ~\Hole
e
DNO
k
^
Hole — U — »offset |
tTongueWidth
1
f-
~*~
-}
1
"V
BarrelLength
4 C\ \
I.D.
^ — *** \O.D
tHole -/
ThomasiBetts
© 2000 Thomas & Belts Corporation. Specifications are subject to change without notice. WWW.tflb.COm