Wine Cellar Cooling Solutions...Wine Cellar Cooling Solutions Sold exclusively through HVAC/R...
Transcript of Wine Cellar Cooling Solutions...Wine Cellar Cooling Solutions Sold exclusively through HVAC/R...
Wine Cellar Cooling SolutionsSold exclusively through HVAC/R wholesalers
855.235.5271 www.CellarCool.com
Our BTU Wizard will walk you through a series of questions about your cellar project and will help you size and select the proper cooling system. If you have any questions or need any assistance, contact us at 1-855-235-5271 or by using our contact form.
Please Note: There are several factors such as glass, stone, concrete, etc. which will change the required btu amount needed to properly cool your wine room. Under sizing your cooling unit can lead to premature failure and/or prevent the system from reaching the desired set temperature.
*Change any default values to your specific climate needs.
855.235.5271 REV#102815www.CellarCool.com
BTU WIZARDwww.CellarCool.com
SMARTCONTROL
· Temperature and humidity monitoring
· Cooling system component monitoring
· Cleaning and maintenance notifications
· Intuitive touch-screen displays — LCD controller interface
· Complex multi-function control systems that incorporate self-learning control algorithms
· Receive up to the minute alerts on your cell phone or mobile device
· Dashboard providing real time information
· View graphs of your cellar’s history
· This system will catch issues before the unit malfunctions
· View a history of any problems
Wine collecting is a serious investment which requires the proper environment and time. These elements allow wine to evolve into a pristine state in which a true connoisseur can embellish and enjoy.
These prized collections need to be stored in the proper environment of consistent temperature and humidity for long term aging. A properly prepared cellar along with a high quality environmental stabilization system is critical.
The challenge is not only to assure that the environment stays consistent over time, but that the equipment maintaining the environment works efficiently for an extended period of time. Most collectors do not take into consideration that mechanical cooling systems will work constantly, for thousands of hours, to keep the environment at the proper temperature and humidity. Eventually these mechanical cooling systems will require cleaning, maintenance and repair. However in many cases, the need for a simple cleaning is overlooked until a problem with maintaining the environment has occurred. Collectors are then caught off guard and worry that the collections have been compromised.
It is with this issue in mind that we have created the Smart Control cellar monitoring system. For the past two years, we have worked tirelessly with a major control manufacture to develop the latest technology to monitor wine cellar environments. Our new Smart Control cellar monitoring system is fully integrated to not only monitor the cellar environment, but to monitor each component of the cellars cooling system equipment to assure all systems operate seamlessly to maintain the ideal environment for aging of fine wines. The communication module keeps collectors in the loop on the operating status of the system and cellar environment via website tracking and smart phone integration.
Cellar Monitoring System
FEATURES:
WINE CELLAR COOLING SYSTEMS
COMING SOON
855.235.5271 REV#102815www.CellarCool.com
Introducing the Cold Weather Start Kit by CellarCool. This kit was designed exclusively for our split-systems where the condensing unit will be installed in extremely cold environments. Our split systems are designed to be adaptable to almost any install, as the condensing unit can be located in a variety of locations such as a mechanical room, basement, back yard, or even a rooftop. Our split systems were designed to operate with the condensing unit exposed to temperatures between 20° F and 110° F. However, there are some areas in the country that may drop below 20° F. Due to these conditions CellarCool designed the Cold Weather Start Kit.
So, when the outside temperatures drop, the pressure in the system drops as well. This presents a challenge because our systems operate using a pump down cycle and a low pressure switch to turn the compressor on and off. However, when the temperature drops below 20° F the pressure in the system is too low to start the compressor. The use of an electronic bypass is needed to start the compressor and temperature controlled heaters installed on the receiver are needed to raise the pressure in the system to optimal levels.
The Cold Weather Start Kit will bypass the low pressure switch on startup and keep the pressure in the system high enough to operate correctly for environments as cold as -15° F.
It is important that the cooling system stays operational during cold weather conditions, as heating the house using the central HVAC system will indirectly increase the temperature of the wine cellar. This kit will ensure that the cooling system will continue to operate efficiently in cold weather environments to maintain an optimal wine storage temperature.
The Cold Weather Start Kit can be ordered as an upgrade on a new unit from the factory, or as an option for a unit already installed in the field, which comes with instructions to guide a technician through the install.
www.cellarcool.com/cold-weather-start-kit
We recommend the Cold Weather Start Kit for the regions shown below in blue.* It is also recommended for any areas that reach -15° F (-26.1° C)
855.235.5271 REV#102815www.CellarCool.com
ApprovedC US
Specifications
Key Features
Optional Accessories
• Direct replacement for Breezaire and Wine Mate• Dynamic air flow• 30°F temperature differential
Rear power cord
• Flexible mounting bracket• Advanced digital controller• Ductable exterior exhaust • Built-in air sensor
Model CX2200 CX3300 CX4400 CX8800Cellar Size (cu. ft.) 300 650 1000 2000
BTU/h @ 55°F 1453 2049 2962 4754
CFM 118 126 216 374
Dimensions 14.25”W x 13.25”H x 16.38”D 14.25”W x 19.75”H x 21.63”D 16.25”W x 22”H x 22.25”D
Refrigerant R-134a R-134a R-134a R-134a
HP 1/8 1/6+ 1/4+ 1/2+
Voltage Rating (20 amp dedicated circuit required)
115V (230V special order only)
Weight (lb.) 65 66 67 74
Amps (Starting/Running) 28 / 4.5 30 / 4.9 32 / 9 36 / 10
dBA (Evaporator/Condenser) 63 / 63 63 / 64 63 / 64 68 / 68
Drainline 3/8” Condensate
Installation Through-the-Wall, Partially Ducted
Thermostat Advanced electronic control system
Temp. Delta 30°F temperature differential (maintains proper cellar temperature when exhaust environment does not exceed 85°F)
Warranty 2-year parts and labor / 5-year compressor
855.235.5271 REV#102815www.CellarCool.com
CX
ApprovedC US
Specifications
Key Features• Slim line design• Mounts above door• Dynamic air flow
• 30°F temperature differential • Extremely quiet in cellar operation• Liquid temperature bottle probe
Model SL2500Cellar Size (cu. ft.) 350
BTU/h @ 55°F 1453
CFM 94
Dimensions 22”W x 10.25”H x 19”D
Refrigerant R-134a
HP 1/8
Voltage Rating (20 amp dedicated circuit required)
115V (230V special order only)
Weight (lb.) 50
Amps (Starting/Running) 17.5 / 3.5
dBA (Evaporator/Condenser) 59 / 53
Drainline 3/8” Condensate
Installation Through-the-wall, ideally above a doorway
Thermostat Advanced electronic control system
Temp. Delta 30°F temperature differential (maintains proper cellar temperature when exhaust environment does not exceed 85°F)
Warranty 2-year parts and labor
855.235.5271 REV#102815www.CellarCool.com
SL2500 Self Contained(Through-the-Wall Systems)
ApprovedC US
Specifications
Key Features
Optional Accessories
• Variable speed fans• Operates in extreme environments• 55°F temperature differential
Advanced electronic control system remote, ducting plenum, exterior grille
• Flexible mounting bracket• Control mounted on front of unit or remote• Ductable exterior exhaust• Liquid temperature bottle probe
Model Ultimate 3300 Ultimate 4400 Ultimate 8800 Cellar Size (cu. ft.) 800 1250 2000
BTU/h @ 55°F 2688 4200 5760
CFM 256 256 283
Dimensions 14.25”W x 15.75”H x 26”D 16.25”W x 22”H x 27.5”D
Refrigerant R-134a R-134a R-134a
HP 1/4+ 1/4+ 3/4+
Voltage Rating (20 amp dedicated circuit required)
115V (230V special order only)
Weight (lb.) 115 115 150
Amps (Starting/Running) 32 / 9 32 / 9 36 / 17
dBA (Low/Medium/High) 51 / 58 / 66 51 / 58 / 66 57 / 59 / 61
Drainline 1/2” Condensate
Installation Through-the-Wall, partially ducted, fully ducted
Thermostat Advanced electronic control system
Temp. Delta 55°F temperature differential (maintains proper cellar temperature when exhaust environment does not exceed 110°F)
Outside Venting Can be done if the outside temperature does not exceed 110°F, the external grille cover is highly recommended
Ducting Options Unit can be fully ducted
Warranty 2-year parts and labor
855.235.5271 REV#102815www.CellarCool.com
Ultimate Self Contained(Through-the-Wall Systems)
ApprovedC US
Specifications
Key Features
Optional Accessories
• Entire unit mounts up to 25 ft. away• Virtually silent in cellar operation• Operates in extreme environments
Ducting plenum, exterior grille
• 55°F temperature differential• Remote advanced electronic controller w/50 ft. cable• Includes duct boots on exhaust and supply side • Liquid temperature bottle probe
Model Ultimate-FD3300 Ultimate-FD4400 Ultimate-FD8800Cellar Size (cu. ft.) 800 1250 2000
BTU/h @ 55°F 2688 4200 5760
CFM 256 256 283
Dimensions 14.25”W x 21.75”H x 49.5”D 14.25”W x 28.5”H x 51.5”D
Refrigerant R-134a R-134a R-134a
HP 1/2 1/2 1/2+
Voltage Rating (20 amp dedicated circuit required)
115V (230V special order only)
Weight (lb.) 115 115 150
Amps (starting/running) 32 / 9 32 / 9 36 / 10
Ducting Size 8” Supply and Return8”Exhaust and 8” Intake
8” Supply and 10” Return8” Exhaust and 10” Intake
Drainline 1/2” Condensate
Installation Within 25 ducted feet of cellar
Thermostat Advanced electronic control system
Temp. Delta 55°F temperature differential (maintains proper cellar temperature when exhaust environment does not exceed 110°F)
Outside Venting Can be done if the outside temperature does not exceed 110°F, the external grille cover is highly recommended
Warranty 2-year parts and labor
855.235.5271 REV#102815www.CellarCool.com
Ultimate Fully Ducted(w/Remote Control)
ApprovedC US
Model CM 2500-S CM 3500-S CM 5000-SCellar Size (cu. ft.) 500 1000 2000
BTU/h @ 55°F 1540 3650 4450
CFM 107 321 321
Dimensions Evaporator: 22.05” W x 11.08” H x 11.34”D Condenser: 16” W x 10” H x 11.5” D
Evaporator: 35.75”W x 14.5”H x 12.75”D Condenser: 17.25”W x 13”H x 13.5”D
Refrigerant R-134a R-134a R-134a
HP 1/5 1/2 1/2
Voltage Rating (20 amp dedicated circuit required)
115V (230V special order only)
Weight (lb.) Evaporator: 40.6, Condenser: 33.1 Evaporator: 80, Condenser: 69 Evaporator: 80, Condenser: 69
Amps (Starting/Running) Evaporator: 2 / 1, Condenser: 11 / 3.81 Evaporator: 1 / 1, Condenser: 48 / 9.5 Evaporator: 1 / 1, Condenser: 48 / 9.5
dBA (Evaporator) Evaporator: 52, Condenser: 65 Evaporator: 58.5, Condenser: 65 Evaporator: 58.5, Condenser: 65
Line Set Please refer to the unit Owners Manual
Drainline 1/4” ID
Installation Evaporator is installed in the cellar, Condenser is installed up to 100 line ft. away and with the installation specifications found in the owners manual. Allow for adequate airflow.
Thermostat Digital Control Display
Temp. Delta 55°F temperature differential(maintains proper cellar temperature when exhaust environment does not exceed 110°F)
Warranty 2-year parts and labor
• Ready for “Plug-and-Play” installation• Advanced electronic control system
• 55°F temperature differential• Front grille and mounting bracket are paintable• Liquid bottle probe & condensate pump included
Specifications
Key Features* Front grille and mounting bracket have been painted to match the ceiling
855.235.5271 REV#102815www.CellarCool.com
Split Ceiling Mount(Split Systems — Evaporator/Condenser/Control)
Optional Accessories
Cold Weather Start Kit, Active Humidity Control System
ApprovedC US
Split Wall Mount(Split Systems — Evaporator/Condenser/Control)
Specifications
Key Features
Optional Accessories
855.235.5271 REV#102815www.CellarCool.com
• Ready for “Plug-and-Play” installation• Flexible wall mounting coils • Quiet and efficient in cellar operation
Exterior condenser housing, Cold Weather Start Kit
• 55°F temperature differential• Advanced electronic control system• Liquid temperature bottle probe• With built-in control
Model WM2500-S WM3500-S WM5000-SCellar Size (cu. ft.) 500 1000 2000
BTU/h @ 55°F 1620 4715 6006
CFM 94 270 278
Dimensions Evaporator: 20”W x 10.5”H x 13”DCondenser: 11.5”W x 10.5”H x 14”D
Evaporator: 20.56”W x 15.5”H x 16”DCondenser: 12”W x 13.5”H x 18”D
Evaporator: 20.56”W x 15.5”H x 16”DCondenser: 12”W x 13.5”H x 18”D
Refrigerant R-134a R-134a R-134a
HP 1/5 1/2 1/2+
Voltage Rating (20 amp dedicated circuit required)
115V (230V special order only)
Weight (lb.) Evaporator: 25, Condenser: 36 Evaporator: 56, Condenser: 56 Evaporator: 56, Condenser: 66
Amps (Starting/Running) Evaporator: 2 / 1, Condenser: 11 / 4 Evaporator: 2 / 1, Condenser: 15 / 10 Evaporator: 2 / 1, Condenser: 18 / 9
dBA (Evaporator/Condenser) 51 / 65 54 / 65 54 / 65
Line Set Please refer to the unit Owner’s Manual
Drainline 1/2” Condensate
Installation Evaporator coil installed in the cellar. Condenser up to 100 line feet away. Follow owners manual specifications
Thermostat Advanced electronic control system
Temp. Delta 55°F temperature differential (maintains proper cellar temperature when exhaust environment does not exceed 110°F)
Warranty 2-year parts and labor
ApprovedC US
• Ready for “Plug-and-Play” installation• Coils ducted up to 25 feet away • Advanced electronic control system
• Sleek black powder coated finish• 55°F temperature differential• Liquid temperature bottle probe
Exterior condenser housing, Cold Weather Start Kit
Specifications
Key Features
Optional Accessories
Model FD3500-S FD5000-SCellar Size (cu. ft.) 1000 2000
BTU/h @ 55°F 4715 6006
CFM 200 200
Dimensions Evaporator: 23.75”W x 15”H x 22.5”D / Condenser: 12”W x 13.5”H x 18”D
Refrigerant R-134a R-134a
HP 1/2 1/2+
Voltage Rating (20 amp dedicated circuit required)
115V (230V special order only)
Weight (lb.) Evaporator: 57, Condenser: 66
Amps (Starting/Running) Evaporator: 2 / 1, Condenser: 15 / 10 Evaporator: 2 / 1, Condenser: 11 / 4
dBA (Evaporator/Condenser) 54 / 65 54 / 65
Duct 10” return, 8” supply
Line Set Please refer to the unit Owner’s Manual
Drainline 1/2” Condensate
Installation Up to 256 ft. away. Follow Owner’s Manual specifications
Thermostat Advanced electronic control system remote
Temp. Delta 55°F temperature differential (maintains proper cellar temperature when exhaust environment does not exceed 110°F)
Warranty 2-year parts and labor
Split Fully Ducted(Split Systems — Evaporator/Condenser/Control)
855.235.5271 REV#102815www.CellarCool.com
ApprovedC US
• This Model is a Ductless Split Only• Ready for “Plug-and-Play” installation• Adjustable fan speed control• Flexible wall mount or ceiling joist mount
• Black exterior to hide unit behind a wood grill• Extremely quiet in cellar operation• 55°F temperature differential• Liquid temperature bottle probe
Exterior condenser housing
Split Horizontal Mount(Split Systems — Evaporator/Condenser/Control)
Specifications
Key Features
Optional Accessories
Model HM2500-S HM3500-S HM5000-S HM6500-SCellar Size (cu. ft.) 650 1000 1500 2000
BTU/h @ 55°F 3100 3500 ≈4100 6500
CFM 214 252 456 456
Dimensions 47”W x 12”H x 12”D
Refrigerant R-134a R-134a R-134a R-134a
HP 1/4 1/3 1/3++ 1/2
Voltage Rating (20 amp dedicated circuit required)
115V (230V special order only)
Coil Weight (lb.) 60 60 65 65
Amps (Starting/Running)Evaporator: 1.4 / 1.04Condenser: 28 / 5.4
Evaporator: 1.4 / 1.14Condenser: 32.7 / 7.2
Evaporator: 2.5 / 2Condenser: 40 / 8.2
Evaporator: 2.5 / 2.1Condenser: 58.8 / 11.3
dBA (Evaporator) 48 56 56 59
Line Set Please refer to the unit Owner’s Manual
Drainline 1/2” Condensate
Installation Evaporator coil installed in the cellar. Condenser up to 100 line feet away.
Thermostat Advanced electronic control system remote
Temp. Delta 55°F
Warranty 2-year parts and labor
855.235.5271 REV#102815www.CellarCool.com
ApprovedC US
• This Model is a Ductless Split Only• Ready for “Plug-and-Play” installation• Adjustable fan speed control• Flexible wall mount or ceiling joist mount
Exterior condenser housing
• Black exterior to hide unit behind a wood grill• Extremely quiet in cellar operation• 55°F temperature differential• Liquid temperature bottle probe
Split Horizontal Mount Twin(Split Systems — Evaporator/Condenser/Control)
Specifications
Key Features
Optional Accessories
Model HM8200 TWIN-S HM13000 TWIN-SCellar Size (cu. ft.) 3000 4000
BTU/h @ 55°F 8140 13,930
CFM 456 + 456 456 + 456
Units HM5000 + HM5000 HM6500 + HM6500
Dimensions 47”W x 12”H x 12”D (2 units)
Refrigerant R134a
HP 1/3 + 1/3 1/2 + 1/2
Voltage Rating (20 amp dedicated circuit required)
115V 230V only
Coil Weight (lb.) 60 + 65 65 + 65
Amps (Starting/Running) 2.5 (per Evaporator) 2.5 (per Evaporator)
Line Set Please refer to the unit Owner’s Manual
Drainline 1/2” Condensate
Installation Evaporator coil installed in the cellar. Condenser up to 100 line feet away.
Thermostat Advanced electronic control system
Temp. Delta 55°F
Warranty 2-year parts and labor
855.235.5271 REV#102815www.CellarCool.com
ApprovedC US
• This Model is a Ductless Split Only• Ready for “Plug-and-Play” installation• Adjustable fan speed control• Coil mounted in void corners of racking
Exterior condenser housing
• Black exterior to hide unit behind racking• Extremely quiet in cellar operation• 55°F temperature differential• Liquid temperature bottle probe
Split Vertical Mount(Split Systems — Evaporator/Condenser/Control)
Specifications
Key Features
Optional Accessories
Model VM2500-S VM3500-S VM5000-S VM6500-SCellar Size (cu. ft.) 650 1000 1500 2000
BTU/h @ 55°F 3100 3500 ≈4100 6500
CFM 214 252 456 456
Dimensions 12”W x 47”H x 12”D
Refrigerant R-134a R-134a R-134a R-134a
HP 1/4 1/3 1/3++ 1/2
Voltage Rating (20 amp dedicated circuit required)
115V (230V special order only)
Coil Weight (lb.) 60 60 65 65
Amps (Starting/Running)Evaporator: 1.4 / 1.04Condenser: 28 / 5.4
Evaporator: 1.4 / 1.14Condenser: 32.7 / 7.2
Evaporator: 2.5 / 2Condenser: 40 / 8.2
Evaporator: 2.5 / 2.1Condenser: 58.8 / 11.3
dBA (Evaporator) 48 56 56 59
Line Set Please refer to the unit Owner’s Manual
Drainline 1/2” Condensate
Installation Evaporator coil installed in the cellar. Condenser up to 100 line feet away.
Thermostat Advanced electronic control system remote
Temp. Delta 55°F
Warranty 2-year parts and labor
855.235.5271 REV#102815www.CellarCool.com
ApprovedC US
• This Model is a Ductless Split Only• Ready for “Plug-and-Play” installation• Adjustable fan speed control• Coil mounted in void corners of racking
Exterior condenser housing
• Black exterior to hide unit behind racking• Extremely quiet in cellar operation• 55°F temperature differential• Liquid temperature bottle probe
Split Vertical Mount Twin(Split Systems — Evaporator/Condenser/Control)
Specifications
Key Features
Optional Accessories
Model VM8200 TWIN-S VM13000 TWIN-SCellar Size (cu. ft.) 3000 4000
BTU/h @ 55°F 8140 13,930
CFM 456 + 456 456 + 456
Units VM5000 + VM5000 VM6500 + VM6500
Dimensions 12”W x 47”H x 12”D (2 units)
Refrigerant R134a
HP 1/3 + 1/3 1/2 + 1/2
Voltage Rating (20 amp dedicated circuit required)
115V 230V only
Coil Weight (lb.) 60 + 65 65 + 65
Amps (Starting/Running) 2.5 (per Evaporator) 2.5 (per Evaporator
Line Set Please refer to the unit Owner’s Manual
Drainline 1/2” Condensate
Installation Evaporator coil installed in the cellar. Condenser up to 100 line feet away.
Thermostat Advanced electronic control system
Temp. Delta 55°F
Warranty 2-year parts and labor
855.235.5271 REV#102815www.CellarCool.com
ApprovedC US
Water-Cooled CondenserOur new water-cooled systems come in four evaporator coil configurations to provide several mounting options. Horizontal Mount (HM), Vertical Mount (VM), Wall Mount (WM) and Fully Ducted (FD) systems. These water-cooled systems are an alternative to our traditional air-cooled systems and rely on water to cool the condenser instead of fans.
855.235.5271 REV#102815www.CellarCool.com
Water-Cooled Condenser(Split Systems — Evaporator/Control/Water-Cooled Condenser)
Model WM3500-S-WC FD3500-S-WC HM3500-S-WC HM6500-S-WC VM3500-S-WC VM6500-S-WC
Cellar Size (cu. ft.) 1000 1000 1000 2000 1000 2000
BTU/h @ 55°F 4715 4715 3500 6500 3500 6500
CFM 270 200 252 456 252 456
Dimensions - Evaporator
20.5”W x 15.5”H x 14.5”D 23.75”W x 15”H x 22.5”D 47”W x 12”H x 12”D 12”W x 47”H x 12”D
Refrigerant R-134a R-134a R-134a R-134a R-134a R-134a
HP 1/2 1/2 1/3 1/2 1/3 1/2
Voltage Rating (20 amp dedicated circuit required)
115V (230V special order only)
Weight (lb.) 56 57 60 59 60 65
Amps (Starting/Running)
1.4 / 1.14 2 / 1 1.4 / 1.14 2.5 / 2.1 1.4 / 1.14 2.5 / 2.1
dBA 56 54 56 59 56 59
Line Set Please refer to the unit Owner’s Manual
Drainline 1/2” Condensate
Installation Evaporator Coil Installed in the Cellar
Up to 25 feet away from cellar Evaporator coil installed in the cellar
Thermostat Built-In Thermostat Control Remote Thermostat Control
Temp. Delta 55°F
Warranty 2-year parts and labor
Optional Accessories
Exterior condenser housing