Wind Resistant Garage Door And Frame Installation

8
Planning, Development, and Codes, 111 S. Cherry Suite 3500 Olathe, Ks 66061 Phone: 913-715-2200 Fax: 913-715-2299, http://buildingcodes.jocogov.org Johnson County Kansas Unincorporated This initiative has been developed by agreement with the Johnson County Building Officials (JOCOBO) and the Home Builders Association of Greater Kansas City. Wind Resistant Garage Door And Frame Installation

Transcript of Wind Resistant Garage Door And Frame Installation

Page 1: Wind Resistant Garage Door And Frame Installation

Planning, Development, and Codes, 111 S. Cherry Suite 3500 Olathe, Ks 66061

Phone: 913-715-2200 Fax: 913-715-2299, http://buildingcodes.jocogov.org

Johnson County Kansas Unincorporated

This initiative has been developed by agreement with the Johnson County Building Officials (JOCOBO) and the Home Builders Association of Greater Kansas City.

Wind Resistant Garage Door And

Frame Installation

Page 2: Wind Resistant Garage Door And Frame Installation

90 m.p.h. Wind Resistant Garage Door and Frame Installation Code Reference: DASMA Garage Door Wind Load Guide BASED ON THE 2000 / 2003 / 2006 INTERNATIONAL RESIDENTIAL CODES (IRC) Similar to other doors and windows, the design and installation of garage doors and frames shall comply with the design wind load for the structure. The basic wind speed for the Kansas City Metropolitan area is 90 mph (3-second gust). For urban and suburban areas, Exposure Category B, this wind speed translates into 12.8 psf positive wind pressure and 14.8 negative wind pressure for a 9’x7’ door; for larger doors the pressure exerted is 12.4 psf positive and 13.8 psf negative. Exposure B can be assumed unless the site meets the definition of another category (RE: IRC Section R301.2.1.4) One means of establishing that the door is code compliant is through labeling. The trade asso-ciation known as the Door and Access Systems Manufacturers Association International (DASMA) has a certified labeling program. The label that DASMA allows t be affixed to the door clearly indicates the wind speed (in psf) for which the door has been certified. Form more information on this program see DASMA’s web side at: www.dasma.com Also see DASMA Technical Data Sheet #155 for an overview of the IRC requirements. Garage doors are usually the largest openings in a house, and their failure in strong winds can lead to partial collapse of the house. Installation Procedures - Installation shall comply with the attached diagrams (Figures 1, 2, 3, and 4). The door and track installation shall comply with the attached diagrams or the manufacturers installation instructions, whichever is most restrictive. Inspection Procedures - Door and frame installation shall be verified for compliance prior to final inspection.

• A copy of the manufacturers installation instructions shall be attached to the back of the garage door.

• The installer shall attach a certification label to the door indicating compliance with the wind 90 mph wind load conditions and that the installation conforms to the manufactur-ers installation instructions.

Page 3: Wind Resistant Garage Door And Frame Installation

10’

No

te: F

or

clar

ity,1

00

0 lb

. h

ead

er-t

o-ja

ck s

trap

on

b

oth

sid

es o

f op

enin

g

un

-d

er 2

x 6

H fr

ame,

no

t sh

ow

n ,

Ref.

No

. LST

A2

4

Page 4: Wind Resistant Garage Door And Frame Installation

10’

No

te: F

or

clar

ity,1

00

0 lb

. h

ead

er-t

o-ja

ck s

trap

on

b

oth

sid

es o

f op

enin

g

u

nd

er 2

x 6

H fr

ame,

no

t sh

ow

n ,

Ref.

No

. LST

A2

4

Page 5: Wind Resistant Garage Door And Frame Installation
Page 6: Wind Resistant Garage Door And Frame Installation
Page 7: Wind Resistant Garage Door And Frame Installation

Residential And Commercial Wind Load Guides DASMA has developed, and continues to develop, a number of resources to assist those connected with the building industry by clarifying the relationship between wind loads and large doors such as garage doors and rolling doors. These resources are intended to aid in the process of specifying these types of doors for buildings, which would result in effective resistance to required wind loads in specific applica-tions. One prominent approach DASMA has taken is to publish documents that contain wind loads specific to garage doors and rolling doors. The first such “wind load guide” was based on the wind load provisions of the Standard Building Code, because of the high susceptibility to hurricane-induced high wind events in the areas that predominantly adopt and enforce the SBC. Because DASMA recognized that non-tornadic high wind events could occur anywhere in the U.S., subsequent wind load guides have been released based on other U.S. building codes. Residential guides are associated with doors mounted on buildings with roof slopes of 10 degrees (2:12) and greater, while commercial guides are associated with doors mounted on buildings with roof slopes of less than 10 degrees (often flat.) Many of the guides for a particular code are subdivided by “Exposure” categories. Pre-1999 codes and standards define these “Exposures” as follows (source: ASCE 7-93): B: Urban and suburban areas, wooded areas, or other terrain with numerous closely spaced obstructions having the size of single-family dwellings or larger. C: Open terrain with scattered obstructions having heights generally less than 30 feet. D: Flat, unobstructed areas exposed to wind flowing over large bodies of water. Exposure conditions C and D were redefined with the publication of ASCE 7-98. In that document, shorelines in hurricane-prone areas became classified as “Exposure C”, and shorelines qualifying as Exposure D were more clearly described (inland waterways, the Great Lakes and coastal areas of Cali-fornia, Oregon, Washington, and Alaska.) Beginning with ASCE 7-05, Exposures B and D have been given measurable definitions while Expo-sure C “shall apply for all cases where Exposures B and D do not apply”. Because so many buildings qualify as Exposure B (as many as 80% per ASCE 7), consideration should be given to evaluating the potential for using Exposure B, particularly with respect to one- and two family dwelling construction, before conservatively using Exposure C without site evaluation.

155

Page 8: Wind Resistant Garage Door And Frame Installation

155

DASMA is committed to accurate and complete information that can be understood by all interested parties, along with a dedication to a nationwide view concerning their products. Furthermore, DASMA is committed to keeping abreast of continued code development by updating and creating “wind load guide” information whenever needed. DASMA has chosen various noteworthy standards and local, state and model building codes on which to base development of residential and commercial “wind load guides”, as follows: (Click on a code to view the Wind Load Guide related to that code)

NOTE: Wind load values shown in the above tables are based on buildings with an “importance factor” of 1.0. For buildings representing a substantial hazard to human life in the event of failure, or buildings designated as “essential facilities”, tabulated wind load values are to be multiplied by a factor of 1.15. Descriptions of some of these types of buildings can be found in the referenced documents.

a. 1999 Standard Building Code

n. South Carolina Residential Code application (use 155l or 155m)

f. 1994 South Florida Building Code, Dade & Bro-ward County editions

o. Florida Building Code

a. 1999 Standard Building Code j. ASCE 7-95

b. 1997 Uniform Building Code k. ASCE 7-98/ASCE 7-02/ASCE 7-05

c. 1999 National Building Code l. 2000/2003/2006 International Building Codes

d. 1995 National Building Code of Canada m. 2000/2003/2006 International Residential Codes

e. 1998 CABO One- and Two-Family Dwelling Code

n. South Carolina Residential Code application (use 155l or 155m)

f. 1994 South Florida Building Code, Dade & Bro-ward County editions

o. Florida Building Code

g. Texas Building Code for Windstorm Resistant Construction

p. Martin County, Florida

h. North Carolina Residential State Building Code q. NFPA 5000

i. ASCE 7-93 r. 2005 National Building Code of Canada (NBCC)