Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to...
Transcript of Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to...
![Page 1: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000](https://reader033.fdocuments.in/reader033/viewer/2022051601/5abad5e37f8b9a24028bf0f0/html5/thumbnails/1.jpg)
Why Acoustic Sand Detectors
don’t work?
![Page 2: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000](https://reader033.fdocuments.in/reader033/viewer/2022051601/5abad5e37f8b9a24028bf0f0/html5/thumbnails/2.jpg)
“The well is shut-in
yet we keep getting
indications of sand
production!”
Operator issues #1
![Page 3: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000](https://reader033.fdocuments.in/reader033/viewer/2022051601/5abad5e37f8b9a24028bf0f0/html5/thumbnails/3.jpg)
“ We know we are
producing sand as
we keep filling up
our separator but
the sand detector
shows zero sand
production.”
Operator issues #2
![Page 4: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000](https://reader033.fdocuments.in/reader033/viewer/2022051601/5abad5e37f8b9a24028bf0f0/html5/thumbnails/4.jpg)
“The CRO’s were
getting flooded
with so many sand
alarms we had no
choice but to turn
the system off”
Operator issues #3
![Page 5: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000](https://reader033.fdocuments.in/reader033/viewer/2022051601/5abad5e37f8b9a24028bf0f0/html5/thumbnails/5.jpg)
“Why is it that for many operators
their acoustic monitoring systems
simply don’t work”
Why acoustic detectors don’t work
![Page 6: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000](https://reader033.fdocuments.in/reader033/viewer/2022051601/5abad5e37f8b9a24028bf0f0/html5/thumbnails/6.jpg)
Detector fundamentals
• Passive microphone
transducer
• Detects noise of particles
impacting on pipe wall
• Also detects flow noise
and mechanical noise
![Page 7: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000](https://reader033.fdocuments.in/reader033/viewer/2022051601/5abad5e37f8b9a24028bf0f0/html5/thumbnails/7.jpg)
• Filter used to ensure
noise is predominantly
due to sand impacts.
Filter
• Not possible to
completely isolate sand
noise
![Page 8: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000](https://reader033.fdocuments.in/reader033/viewer/2022051601/5abad5e37f8b9a24028bf0f0/html5/thumbnails/8.jpg)
Sand Rate
• Quantify each wells sand
production
• Predict sand deposition in
vessels
• Estimate erosion
![Page 9: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000](https://reader033.fdocuments.in/reader033/viewer/2022051601/5abad5e37f8b9a24028bf0f0/html5/thumbnails/9.jpg)
Calibration
Real time process data
• Flow rates: Oil, Gas, Water
• Velocity
• Pressure & Temperature
• Static Inputs
![Page 10: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000](https://reader033.fdocuments.in/reader033/viewer/2022051601/5abad5e37f8b9a24028bf0f0/html5/thumbnails/10.jpg)
Background noise / Zero
• Flow well at different rates
Background noise curve
y = 3x3 - 40x
2 + 533x + 2000
0
2000
4000
6000
8000
10000
12000
0 2 4 6 8 10 12 14 16
velocity [m/s]
sig
nal [1
00n
V]
Velocity Signal [100nV]
0 m/s 2000
5 m/s 4 000
10 m/s 6 000
15 m/s 10 000
• Establish background
noise at each rate
• Determine background
noise curve / zero values
![Page 11: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000](https://reader033.fdocuments.in/reader033/viewer/2022051601/5abad5e37f8b9a24028bf0f0/html5/thumbnails/11.jpg)
Sand noise / Step
• Flow well at different rates
• Inject known quantities of
sand at each rate
• Determine sand curve /
step values
Sand curve [1g/s]
y = 11x3 - 240x
2 + 3533x - 0
0
5000
10000
15000
20000
25000
30000
35000
40000
0 2 4 6 8 10 12 14 16
velocity [m/s]
sig
nal [1
00n
V]
Velocity Signal [100nV]
0 m/s 0
5 m/s 13 000
10 m/s 22 000
15 m/s 35 000
![Page 12: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000](https://reader033.fdocuments.in/reader033/viewer/2022051601/5abad5e37f8b9a24028bf0f0/html5/thumbnails/12.jpg)
Sand Rate
• Calculate sand rate
Production availability
Accurate particle sampling data
Raw data – Background noise
Sand Noise Sand rate =
![Page 13: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000](https://reader033.fdocuments.in/reader033/viewer/2022051601/5abad5e37f8b9a24028bf0f0/html5/thumbnails/13.jpg)
y = 3x3 - 40x2 + 533x + 2000
0
2000
4000
6000
8000
10000
12000
0 2 4 6 8 10 12 14 16
y = 11x3 - 240x2 + 3533x - 0
0
5000
10000
15000
20000
25000
30000
35000
40000
0 2 4 6 8 10 12 14 16
Background noise curve
Sand curve for 1g/s
Velocity = 11 m/s Reading = 21 040 [100nV]
Background noise = 3*113- 40*112 + 533*11 + 2000
= 7016 [100nV]
Sand noise [1g/s] = -11*113- 240*112 + 3533*8 + 0
= 24463 [100nV]
Sandrate = Reading - Background noise
Sand noise
= 21040 - 7016
24463
= 0.57 g/s
Sand Rate – worked example
![Page 14: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000](https://reader033.fdocuments.in/reader033/viewer/2022051601/5abad5e37f8b9a24028bf0f0/html5/thumbnails/14.jpg)
Re-calibration
• Every 6 – 12 months
Stable process flow
POB capacity
• Change in the well flowing
conditions
![Page 15: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000](https://reader033.fdocuments.in/reader033/viewer/2022051601/5abad5e37f8b9a24028bf0f0/html5/thumbnails/15.jpg)
Sand Quantification criteria
Stable process flow
Real time process data
Accurate particle sampling data
POB capacity
Production availability
![Page 16: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000](https://reader033.fdocuments.in/reader033/viewer/2022051601/5abad5e37f8b9a24028bf0f0/html5/thumbnails/16.jpg)
Raw signal interpretation
You are the
experts on your
sand production!
![Page 17: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000](https://reader033.fdocuments.in/reader033/viewer/2022051601/5abad5e37f8b9a24028bf0f0/html5/thumbnails/17.jpg)
Data Interpretation
Acoustic Data – Sand Event?
![Page 18: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000](https://reader033.fdocuments.in/reader033/viewer/2022051601/5abad5e37f8b9a24028bf0f0/html5/thumbnails/18.jpg)
Acoustic data & erosion probe data– Sand Event - Yes
Data Interpretation
![Page 19: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000](https://reader033.fdocuments.in/reader033/viewer/2022051601/5abad5e37f8b9a24028bf0f0/html5/thumbnails/19.jpg)
Acoustic data, erosion probe data, pressure & temperature– Sand Event - Yes
Data Interpretation
![Page 20: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000](https://reader033.fdocuments.in/reader033/viewer/2022051601/5abad5e37f8b9a24028bf0f0/html5/thumbnails/20.jpg)
Raw Signal
• Determine sand
producing wells
• Understand how process
operations affect sand
production
• Estimate erosion – if
used in conjunction with
sampling data.
![Page 21: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000](https://reader033.fdocuments.in/reader033/viewer/2022051601/5abad5e37f8b9a24028bf0f0/html5/thumbnails/21.jpg)
Case Study
Surfactant treatment and Pressure reduction
![Page 22: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000](https://reader033.fdocuments.in/reader033/viewer/2022051601/5abad5e37f8b9a24028bf0f0/html5/thumbnails/22.jpg)
Case Study (cont.)
Surfactant treatment
Platform Trip during pressure reduction
Well cycled
![Page 23: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000](https://reader033.fdocuments.in/reader033/viewer/2022051601/5abad5e37f8b9a24028bf0f0/html5/thumbnails/23.jpg)
Case Study (cont.)
1. Well flowing normally
2. Well cycled closed for 9 hours
3. Noise signal consistent with sand production 4. Well begins to ‘clean-up’
![Page 24: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000](https://reader033.fdocuments.in/reader033/viewer/2022051601/5abad5e37f8b9a24028bf0f0/html5/thumbnails/24.jpg)
SGA – Case Study (cont.)
Outcome: Surfactant treatment successful
Staged pressure reduction successful
! Sand production following well start-ups
! Requirement for ‘hard’ bean-up
![Page 25: Why Acoustic Sand Detectors don’t work? Acoustic Sand Detectors ... alarms we had no choice but to turn the system off ... 0 m/s 2000 5 m/s 4 000 10 m/s 6 000 15 m/s 10 000](https://reader033.fdocuments.in/reader033/viewer/2022051601/5abad5e37f8b9a24028bf0f0/html5/thumbnails/25.jpg)
Sand Monitoring Services
http://www.sand-monitoring.co.uk
Questions?