Country security • Absence of natural disasters • Extremely politically stable • Strong internet privacy laws Power security • Sourcing ring fed power from two power substations with physically separated supply lines • Self-sustaining next generation UPS flywheel enabled power backup system Physical security • Indestructible facility • Highest level physical security infrastructure • Cutting-edge multilayered security and monitoring systems Latest non-lethal fire prevention technology Our state of the art Data Center is one of the most secure, green and energy efficient data centers in the world.

Transcript of White paper rockan data center

Country security• Absence of natural disasters

• Extremely politically stable

• Strong internet privacy laws

Power security• Sourcing ring fed power from two

power substations with physically separated supply lines

• Self-sustaining next generation UPS flywheel enabled power backup system

Physical security• Indestructible facility

• Highest level physical security infrastructure

• Cutting-edge multilayered security and monitoring systems

• Latest non-lethal fire prevention technology

Our state of the art Data Center is one of the most secure, green and energy efficient data centers in the world.

Contact Us:E-mail: [email protected] Phone: +46 (0)8 - 10 48 18

Office:Skogängsvägen 59 163 41 Spånga Sweden

www.rockan.com

Technical specificationsSecurity• The data center is designed to

provide maximum physical security as a former military installation

• Designed to survive a direct nuclear strike

• EMP protection• Multiple layered security perimeter• Security Class 11 steel blast doors• State of the art CCTV system• Biometric readers• Security staff are on site 24/7/365

Power system• Ring fed from two power

substations• All racks are supplied by

A+B UPS power• Physically separated supply lines• Up to 63 amps per rack• Ceramic fuses instead of automatic

circuit breakers• Choose between: 1-phase or 3-phase

feeds• Emergency power

Flywheel UPS system• Higher reliability than pure

battery based UPS• N+1 emergency standby diesel

generators from Caterpillar• Fuel for a minimum of 360 hours of full

load operation• Diesel generator sets can be fuelled

while in operation• The emergency power system is cycled

live on a monthly basis

Cooling system• Cooling provided by fresh outside

air and geothermal properties of the mountain distributed by industrial fans

• PUE of <1.1• Hot and cold aisle design• The cooling system are UPS fed from

both the A and B power

Fire suppression• The data center is equipped with stat-x

fire suppression system• Each rack acts as its own fire zone• Early warning laser smoke

detectors• Non-combustible calcium sulphate

data center flooring system• Non-lethal, environmentally

friendly fire suppressant

Connectivity• The data center is connected with

quad-entry fiberoptic connections• X carriers and ISPs