Weschler DC Ammeter Shunts - Synergy Systems, Inc · Weschler DC Ammeter Shunts Type HA — 1...

34
89 Order Code Amp Length Width MLA-5-50 5 2.0" 1.25" MLA-10-50 10 2.0" 1.25" MLA-15-50 15 2.0" 1.25" MLA-20-50 20 2.0" 1.25" MLA-30-50 30 2.0" 1.25" MLA-50-50 50 2.0" 1.25" MLA-75-50 75 2.0" 1.25" MLA-80-50 80 2.0" 1.25" MLA-100-50 100 2.0" 1.25" MLA-150-50 150 2.0" 1.25" Order Code Amp Length Width MLB-170-50 170 3.25" 1.75" MLB-200-50 200 3.25" 1.75" MLB-250-50 250 3.25" 1.75" MLB-300-50 300 3.25" 1.75" MLB-400-50 400 3.25" 1.75" MLB-500-50 500 3.25" 1.75" MLB-600-50 600 3.25" 1.75" Weschler DC Ammeter Shunts Type HA — 1 Through 500 Amperes Lightweight Types Type Lab — 10 Through 1000 Amperes Type MLC — 800 Through 1200 Amperes Type MLB — 170 Through 600 Amperes Type MLA — 5 Through 150 Amperes ORDERING INFORMATION ORDERING INFORMATION– MLC-50 MV ORDERING INFORMATION– MLC-50 MV ORDERING INFORMATION ORDERING INFORMATION– MLB-50 MV HA Type MLA Lab Type Order Code Amp Length Width MLC-800-50 800 4.5" 2.5" MLC-1000-50 1000 4.5" 2.5" MLC-1200-50 1200 4.5" 2.5" Type HA—50 mV Type HA—100 mV Amp Length Width C-C Mounting Order Code Order Code 1 6.0" 1.25" 5.25" HA-1-50 HA-1-100 2 6.0" 1.25" 5.25" HA-2-50 HA-2-100 5 6.0" 1.25" 5.25" HA-5-50 HA-5-100 10 6.0" 1.25" 5.25" HA-10-50 HA-10-100 20 6.0" 1.25" 5.25" HA-20-50 HA-20-100 50 6.0" 1.25" 5.25" HA-50-50 HA-50-100 100 6.0" 1.25" 5.25" HA-100-50 HA-100-100 200 6.0" 1.25" 5.25" HA-200-50 HA-200-100 300 6.0" 1.25" 5.25" HA-300-50 HA-300-100 500 6.0" 1.25" 5.25" HA-500-50 HA-500-100 NK Technologies DC Current Transducers SPECIFICATIONS ORDERING INFORMATION Hall-effect sensor and signal conditioner in a single package Jumper selectable input ranges to 400 A DT4 Output Signal: 4–20 mA, 0–5 VDC or 0–10 VDC Output Limit: 4-20 mA: 23 mA 0–5 VDC: 5.75 VDC 0–10 VDC: 11.5 VDC Output Polarity: Unipolar, Bipolar available Accuracy: 1.0% FS Power Supply: Universal 20–50 VDC, 22–38 VAC, 2VA Max. Power Input and Output Signal are Not Isolated Power Consumption: 2 VA Loading: 4–20 mA: 650Ω Maximum 0-5VDC: 25kΩ Min. 0-10VDC: 50kΩ Min. Linearity: 0.75% FS Current Ranges: Jumper Selectable 0–400A Sensing Aperture: 0.85" (21.5 mm) Sq Case: UL 94V–0 Flammability Rated Environmental: -4 to 122°F (-20 to 50°C), 0–95% RH Non-Condensing Order Code * Description Output DT1-005-24U-U 50, 75, and 100 A Range 0–5 VDC DT1-420-24U-U 50, 75, and 100 A Range 4–20 mA DT2-005-24U-U 100, 150, and 200 A Range 0–5 VDC DT2-420-24U-U 100, 150, and 200 A Range 4–20 mA DT3-005-24U-U 150, 225, and 300 A Range 0–5 VDC DT3-420-24U-U 150, 225, and 300 A Range 4–20 mA DT4-005-24U-U 200, 300, and 400 A Range 0–5 VDC DT4-420-24U-U 200, 300, and 400 A Range 4–20 mA T RANSDUCERS/ S ENSORS Type Lab — 50 mV Type Lab — 100 mV Amp Length Width Order Code Length Width Order Code 10 5.0" 1.25" LAB-10-50 6.25" 1.25" LAB-10-100 15 5.0" 1.25" LAB-15-50 6.25" 1.25" LAB-15-100 25 5.0" 1.25" LAB-25-50 6.25" 1.25" LAB-25-100 50 5.0" 1.25" LAB-50-50 6.25" 1.25" LAB-50-100 100 5.0" 1.25" LAB-100-50 6.25" 1.25" LAB-100-100 150 5.0" 1.25" LAB-150-50 6.25" 1.25" LAB-150-100 200 5.0" 1.25" LAB-200-50 6.25" 1.25" LAB-200-100 250 6.75" 1.87" LAB-250-50 8.0" 1.875" LAB-250-100 300 6.75" 1.87" LAB-300-50 8.0" 1.875" LAB-300-100 400 6.75" 1.87" LAB-400-50 8.0" 1.875" LAB-400-100 1000 6.75" 2.37" LAB-1000-50 8.0" 2.375" LAB-1000-100 * Add suffix FL for solid core, SP for split core

Transcript of Weschler DC Ammeter Shunts - Synergy Systems, Inc · Weschler DC Ammeter Shunts Type HA — 1...

Page 1: Weschler DC Ammeter Shunts - Synergy Systems, Inc · Weschler DC Ammeter Shunts Type HA — 1 Through 500 Amperes Lightweight Types Type Lab — 10 Through 1000 Amperes Type MLC —

89

Order Code Amp Length Width MLA-5-50 5 2.0" 1.25"MLA-10-50 10 2.0" 1.25"MLA-15-50 15 2.0" 1.25"MLA-20-50 20 2.0" 1.25"MLA-30-50 30 2.0" 1.25"MLA-50-50 50 2.0" 1.25"MLA-75-50 75 2.0" 1.25"MLA-80-50 80 2.0" 1.25"MLA-100-50 100 2.0" 1.25"MLA-150-50 150 2.0" 1.25"

Order Code Amp Length WidthMLB-170-50 170 3.25" 1.75"MLB-200-50 200 3.25" 1.75"MLB-250-50 250 3.25" 1.75"MLB-300-50 300 3.25" 1.75"MLB-400-50 400 3.25" 1.75"MLB-500-50 500 3.25" 1.75"MLB-600-50 600 3.25" 1.75"

Weschler DC Ammeter ShuntsType HA — 1 Through 500 Amperes Lightweight

Types

Type Lab —10 Through 1000 Amperes

Type MLC — 800 Through 1200 Amperes

Type MLB — 170 Through 600 Amperes

Type MLA — 5 Through 150 Amperes

ORDERING INFORMATION

ORDERING INFORMATION– MLC-50 MV

ORDERING INFORMATION– MLC-50 MV

ORDERING INFORMATION

ORDERING INFORMATION– MLB-50 MV

HA Type

MLA

Lab Type

Order Code Amp Length WidthMLC-800-50 800 4.5" 2.5"MLC-1000-50 1000 4.5" 2.5"MLC-1200-50 1200 4.5" 2.5"

Type HA—50 mV Type HA—100 mVAmp Length Width C-C Mounting Order Code Order Code1 6.0" 1.25" 5.25" HA-1-50 HA-1-1002 6.0" 1.25" 5.25" HA-2-50 HA-2-1005 6.0" 1.25" 5.25" HA-5-50 HA-5-10010 6.0" 1.25" 5.25" HA-10-50 HA-10-10020 6.0" 1.25" 5.25" HA-20-50 HA-20-10050 6.0" 1.25" 5.25" HA-50-50 HA-50-100100 6.0" 1.25" 5.25" HA-100-50 HA-100-100200 6.0" 1.25" 5.25" HA-200-50 HA-200-100300 6.0" 1.25" 5.25" HA-300-50 HA-300-100500 6.0" 1.25" 5.25" HA-500-50 HA-500-100

NK Technologies DC Current TransducersSPECIFICATIONS

ORDERING INFORMATION

• Hall-effect sensor and signal conditioner in a single package

• Jumper selectable input ranges to 400 A

DT4

Output Signal: 4–20 mA, 0–5 VDC or 0–10 VDC Output Limit: 4-20 mA: 23 mA

0–5 VDC: 5.75 VDC 0–10 VDC: 11.5 VDC

Output Polarity: Unipolar, Bipolar available Accuracy: 1.0% FS Power Supply: Universal 20–50 VDC, 22–38 VAC, 2VA Max.

Power Input and Output Signal are Not Isolated Power Consumption: 2 VA Loading: 4–20 mA: 650Ω Maximum

0-5VDC: 25kΩ Min. 0-10VDC: 50kΩ Min.

Linearity: 0.75% FS Current Ranges: Jumper Selectable 0–400A Sensing Aperture: 0.85" (21.5 mm) Sq Case: UL 94V–0 Flammability Rated Environmental: -4 to 122°F (-20 to 50°C), 0–95% RH Non-Condensing

Order Code * Description OutputDT1-005-24U-U 50, 75, and 100 A Range 0–5 VDC DT1-420-24U-U 50, 75, and 100 A Range 4–20 mA DT2-005-24U-U 100, 150, and 200 A Range 0–5 VDC DT2-420-24U-U 100, 150, and 200 A Range 4–20 mA DT3-005-24U-U 150, 225, and 300 A Range 0–5 VDC DT3-420-24U-U 150, 225, and 300 A Range 4–20 mA DT4-005-24U-U 200, 300, and 400 A Range 0–5 VDC DT4-420-24U-U 200, 300, and 400 A Range 4–20 mA

T RAN

SDUC

ERS

/S E

NSO

RS

Type Lab — 50 mV Type Lab — 100 mVAmp Length Width Order Code Length Width Order Code10 5.0" 1.25" LAB-10-50 6.25" 1.25" LAB-10-10015 5.0" 1.25" LAB-15-50 6.25" 1.25" LAB-15-10025 5.0" 1.25" LAB-25-50 6.25" 1.25" LAB-25-10050 5.0" 1.25" LAB-50-50 6.25" 1.25" LAB-50-100100 5.0" 1.25" LAB-100-50 6.25" 1.25" LAB-100-100150 5.0" 1.25" LAB-150-50 6.25" 1.25" LAB-150-100200 5.0" 1.25" LAB-200-50 6.25" 1.25" LAB-200-100250 6.75" 1.87" LAB-250-50 8.0" 1.875" LAB-250-100300 6.75" 1.87" LAB-300-50 8.0" 1.875" LAB-300-100400 6.75" 1.87" LAB-400-50 8.0" 1.875" LAB-400-1001000 6.75" 2.37" LAB-1000-50 8.0" 2.375" LAB-1000-100

* Add suffix FL for solid core, SP for split core

Page 2: Weschler DC Ammeter Shunts - Synergy Systems, Inc · Weschler DC Ammeter Shunts Type HA — 1 Through 500 Amperes Lightweight Types Type Lab — 10 Through 1000 Amperes Type MLC —

90

TRAN

SDUCER

S/S

ENSO

RS

Empro ShuntsType A — 20 Through 600 Amperes

Type WT — 600 Through 10000 Amperes

Type B — 300 Through 1000 Amperes

ORDERING INFORMATION

Type C — 1000 Through 2000 Amperes

ORDERING INFORMATION

Type E — 1500 Through 2000 AmperesORDERING INFORMATION

Type B

Type WT

Type C

Type A

Type E

Type B — 50 mV Type B — 100 mVAmp Length Width Order Code Length Width Order Code300 5.875" 1.75" B-300-50 7.75" 1.75" B-300-100400 5.875" 2.00" B-400-50 7.75" 2.00" B-400-100500 5.875" 2.00" B-500-50 7.75" 2.00" B-500-100600 5.875" 2.00" B-600-50 7.75" 2.00" B-600-100750 5.875" 2.25" B-750-50 7.75" 2.25" B-750-100800 5.875" 2.375" B-800-50 7.75" 2.375" B-800-1001000 5.875" 2.50" B-1000-50 7.75" 2.50" B-1000-1001200 5.875" 3.00" B-1200-50 7.75" 3.00" B-1200-100

Type WT — 50 mV Type WT — 100 mVAmp Length Width Order Code Length Width Order Code600 12.0" 3.0" WT-600-100750 12.0" 3.0" WT-750-100800 12.0" 3.0" WT-800-1001000 9.063" 3.0" WT-1000-50 12.0" 3.0" WT-1000-1001200 9.063" 3.0" WT-1200-50 12.0" 4.0" WT-1200-1001500 9.063" 3.0" WT-1500-50 18.5" 4.0" WT-1500-1002000 9.063" 4.0" WT-2000-50 18.5" 4.0" WT-2000-1002500 15.625" 4.0" WT-2500-50 18.5" 5.0" WT-2500-1003000 15.625" 4.0" WT-3000-50 18.5" 5.0" WT-3000-1004000 15.625" 5.0" WT-4000-50 18.563" 5.0" WT-4000-1005000 15.625" 5.0" WT-5000-50 18.563" 5.0" WT-5000-1006000 15.625" 6.0" WT-6000-50 18.563" 6.0" WT-6000-1007500 15.625" 6.0" WT-7500-508000 15.625" 6.0" WT-8000-5010000 16.0" 8.0" WT-10000-50

ORDERING INFORMATION

Type C — 50 mV Type C — 100 mVAmp Length Width Order Code Length Width Order Code1000 9.063" 2.625" C-1000-50 10.875" 2.625" C-1000-1001200 9.063" 3.00" C-1200-50 10.875" 3.00" C-1200-1001500 9.063" 3.00" C-1500-50 10.875" 3.00" C-1500-1002000 9.063" 3.25" C-2000-50 10.875" 3.25" C-2000-100

Type E — 50 mV Type E — 100 mVAmp Length Width Order Code Length Width Order Code1500 9.625" 3.00" E-1500-50 11.25" 3.00" E-1500-1002000 9.625" 4.00" E-2000-50 11.25" 4.00" E-2000-100

Type A — 50 mV Type A — 100 mVAmp Length Width Order Code Length Width Order Code20 4.125" 0.675" A-20-5050 4.125" 0.675" A-50-50 5.75" 0.675" A-50-10075 4.125" 0.675" A-75-50 5.75" 0.675" A-75-100100 4.125" 0.675" A-100-50 5.75" 0.675" A-100-100125 4.125" 0.813" A-125-50150 4.125" 0.938" A-150-50 5.75" 0.93" A-150-100175 4.125" 0.75" A-175-50200 4.125" 0.813" A-200-50 5.75" 0.813" A-200-100250 4.125" 1.063" A-250-50 5.75" 1.063" A-250-100300 4.125" 1.25" A-300-50 5.75" 1.25" A-300-100375 4.625" 0.938" A-375-50 6.25" 0.938" A-375-100400 4.625" 1.00" A-400-50 6.25" 1.00" A-400-100500 4.625" 1.25" A-500-50 6.25" 1.25" A-500-100600 4.625" 1.50" A-600-50 6.25" 1.50" A-600-100

ORDERING INFORMATION

Page 3: Weschler DC Ammeter Shunts - Synergy Systems, Inc · Weschler DC Ammeter Shunts Type HA — 1 Through 500 Amperes Lightweight Types Type Lab — 10 Through 1000 Amperes Type MLC —

Order Code Current Ratio Burden VA Accuracy 60Hz613-101 100:5 1 5%613-1250 125:5 1.25 5%613-151 150:5 1.5 5%613-1750 175:5 1.75 5%613-201 200:5 2.5 4%613-251 250:5 2.5 4%613-301 300:5 3 2%613-401 400:5 3 2%

ORDERING INFORMATION - MODEL 613

Instrument Transformer AC Split Core Current Transformers

ORDERING INFORMATION – MODEL 600ANSI Metering

Order Current Class @ 60 Hz VA @ 1%Code Ratio B0.1 B0.2 B0.5 Class600-401 400:5 2.4 4.8 1.5600-501 500:5 2.4 4.8 2.0600-601 600:5 2.4 2.4 2.5600-801 800:5 1.2 1.2 2.4 5.0600-102 1000:5 1.2 1.2 2.4 7.5600-122 1200:5 0.6 1.2 1.2 15.0600-152 1500:5 0.6 0.6 1.2 20.0600-162 1600:5 0.6 0.6 1.2 20.0600-202 2000:5 0.6 0.6 0.6 30.0

Model 600 – Window 2 x 5.5"Model 601 – Window 4.5 x 4.5"Model 604 – Window 1.42 x 1.53"

Order Code Current Ratio Burden VA Accuracy604-101 100:5 1 ±5%604-1250 125:5 1 ±5%604-151 150:5 2 ±4%604-1750 175:5 2 ±3%604-201 200:5 2 ±2%604-251 250:5 2 ±2%604-301 300:5 2 ±1.5%604-401 400:5 2.5 ±1.5%604-1000T 100:0.1 – ±3%

ORDERING INFORMATION - MODEL 601

ORDERING INFORMATION - MODEL 604

ORDERING INFORMATION - MODEL 600

ANSI MeteringOrder Current Class @ 60 Hz VA @ 1%Code Ratio B0.1 B0.2 B0.5 Class601-401 400:5 4.8 – – 1.0601-501 500:5 4.8 4.8 – 1.5601-601 600:5 2.4 4.8 – 2.0601-801 800:5 1.2 2.4 4.8 2.5601-102 1000:5 1.2 1.2 4.8 5.0601-122 1200:5 1.2 1.2 2.4 10.0601-152 1500:5 1.2 1.2 1.2 15.0601-162 1600:5 1.2 1.2 1.2 15.0601-202 2000:5 0.6 0.6 1.2 20.0

601600

TRAN

SDUC

ERS

/SE

NSO

RS

• 50-400 Hz• 0.6kV, BIL

10kV FW

91

Order Code Current Ratio Burden VA Accuracy 60Hz 606-201 200:5 2.5 2%606-251 250:5 3 1%606-301 300:5 3.5 1%606-351 350:5 4 1%606-401 400:5 5 1%606-501 500:5 6 1%606-601 600:5 8 1%606-751 750:5 10 1%606-801 800:5 12 1%606-102 1000:5 15 1%606-122 1200:5 20 1%

Model 613 – Window 0.8 x 1.95" (indoor only)Model 606 Weatherproof - Window 2.7 x 2.75"Model 608 Weatherproof – Window 2.6 x 6.25"

ORDERING INFORMATION - MODEL 606

Order Code Current Ratio Burden VA Accuracy 60Hz 608-501 500:5 6 1%608-601 600:5 8 1%608-801 800:5 12 1%608-102 1000:5 13 1%608-122 1200:5 16 1%608-152 1500:5 25 1%608-162 1600:5 27 1%606-202 2000:5 33 1%608-252 2500:5 42 1%608-302 3000:5 50 1%608-322 3200:5 54 1%

ORDERING INFORMATION - MODEL 608

Leads (613) #16 AWG, 24" Secondary Cable (606, 608) #16 AWG, 6ft

• 50-400 Hz.• 0.6 kV, BIL 10 kV FW 613

606

Leads (600, 601, 604) #16 AWG, 24"

Page 4: Weschler DC Ammeter Shunts - Synergy Systems, Inc · Weschler DC Ammeter Shunts Type HA — 1 Through 500 Amperes Lightweight Types Type Lab — 10 Through 1000 Amperes Type MLC —

92

TRAN

SDUCER

S/S

ENSO

RS

Flexcore Split Core CT• Seven Opening Sizes • 1 or 5 Amp Secondaries• 0.333V or 1.0V Secondaries• Indoor or Outdoor Use

Flexible split-core opens with atwisting motion. Silicone rubberencapsulation protects againstmoisture, dirt, oil and corona.Remains flexible from -45° to +200°C.

Insulation Level: 0.6kV, BIL 10kV Full Wave Frequency: 50-400HzThermal factor: 1.25 at 30°C, 1.0 at 55°CAccuracy:200:5 thru 300:5 4%400:5 thru 500:5 3%600:5 thru 800:5 2%1000:5 thru 6000:5 1%Leads: 12 feet long with spade connectors,

Black wire = X1, White wire = X2

To Order—Insert Number Code for Each Letter to Select Catalog Number. Order Example: FC-1000/5-8

A ModelFC Split core CTFCL UL Listed (Indoor use only) File E186575

B RatioSee chart for available sizes

C Inside Diameter (inches)4, 6, 8, 11, 18, R, R411(R= 2-3/4 x 6-5/8, R411= 4 x 11)

SPECIFICATIONS

ORDERING INFORMATION

AVAILABLE SIZESRatio 4" 6" 8" 11" 18" R R411 Burden

200/5 X – – – – – – 2VA250/5 X – – – – – – 2VA300/5 X X – – – – – 2VA400/5 X X – – – X – 2VA500/5 X X – – – X – 3VA600/5 X X – – – X – 5VA800/5 X X – – – X – 5VA

1000/5 X X X – – X – 5VA1200/5 X X X – – X – 5VA1500/5 X X X X – X X 15VA1600/5 X X X X – X X 15VA2000/5 X X X X X X X 25VA2400/5 – X X X X X X 30VA2500/5 – X X X X X X 35VA3000/5 – X X X X X X 45VA3500/5 – X X X X X X 45VA4000/5 – X X X X X X 45VA5000/5 – X X X X X X 45VA6000/5 – X X X X X X 45VA

FC

A – B – C

WeschlerAC Voltage Transformers

Order Code Voltage Rating (line to line) Turns Ratio460-069 69.3:120 0.58:1460-120 120:120 1:1460-208 208:120 1.73:1460-240 240:120 2:1460-288 288:120 2.4:1460-300 300:120 2.5:1460-480 480:120 4:1460-600 600:120 5:1460-380 380:120 3.15:1 for 50 Hz

ORDERING INFORMATION

ORDERING INFORMATION

Order Code Voltage Rating (line to line) Turns Ratio467-069 69.3:120 0.58:1467-120 120:120 1:1467-208 208:120 1.73:1467-240 240:120 2:1467-288 288:120 2.4:1467-300 300:120 2.5:1467-480 480:120 4:1467-600 600:120 5:1467-380 380:120 3.17:1 for 50 Hz

467

• 600V Insulation Level, 10kV BIL

• ±1% Accuracy Class up to 5VA Burden

• 40VA at 30°C, 27VA at 55°C

• 60Hz

• 600V Insulation Level, 10kV BIL

• Accuracy Class 0.6W, 1.2x at 60Hz

• 150VA at 30°C, 100VA at 55°C

• 60Hz

460

Page 5: Weschler DC Ammeter Shunts - Synergy Systems, Inc · Weschler DC Ammeter Shunts Type HA — 1 Through 500 Amperes Lightweight Types Type Lab — 10 Through 1000 Amperes Type MLC —

Current Accuracy BurdenCatalog # Ratio @ 60 Hz VA @ 60 Hz5**-500 50:5 ±2% 1.05**-750 75:5 ±2% 1.55**-101 100:5 ±2% 2.05**-151 150:5 ±1% 5.05**-201 200:5 ±1% 5.05**-251 250:5 ±1% 10.05**-301 300:5 ±1% 12.55**-401 400:5 ±1% 12.55**-501 500:5 ±1% 20.05**-601 600:5 ±1% 25.05**-751 750:5 ±1% 25.05**-801 800:5 ±1% 25.05**-102 1000:5 ±1% 25.05**-122 1200:5 ±1% 30.0

Current Accuracy BurdenCatalog # Ratio at 60 Hz at 60 Hz7**-101 100:5 ±2% 2.57**-151 150:5 ±1% 5.07**-201 200:5 ±1% 5.07**-251 250:5 ±1% 5.07**-301 300:5 ±1% 12.57**-401 400:5 ±1% 15.07**-501 500:5 ±1% 25.07**-601 600:5 ±1% 30.07**-751 750:5 ±1% 30.07**-801 800:5 ±1% 35.07**-102 1000:5 ±1% 30.07**-122 1200:5 ±1% 35.07**-152 1500:5 ±1% 40.07**-162 1600:5 ±1% 45.0

Model 76SFT, 76SHT, 76RT, 76RBT, 76RL, 76RBL

Model 7SFT, 7SHT, 7RT, 7RBT, 7RL, 7RBL

Current Accuracy BurdenCatalog # Ratio at 60 Hz at 60 Hz76**-201 200:5 ±1% 5.076**-251 250:5 ±1% 5.076**-301 300:5 ±1% 6.076**-401 400:5 ±1% 10.076**-501 500:5 ±1% 10.076**-601 600:5 ±1% 10.076**-751 750:5 ±1% 10.076**-801 800:5 ±1% 12.576**-102 1000:5 ±1% 10.076**-122 1200:5 ±1% 10.076**-152 1500:5 ±1% 12.576**-162 1600:5 ±1% 12.576**-202 2000:5 ±1% 15.0

2SFT, 2SHT, 2RL, 2DRL

ORDERING INFORMATION

Model 7—Window Dia. 2.50"

Model 76—Window Dia. 3.00"Model 5—Window Dia. 1.56"

Models 2SFT and 2SHT—Window Dia. 1.13"Model 2RL—Window Dia. 1.15" Model 2DRL—Window Dia. 1"

Weschler AC Current Transformers

ORDERING INFORMATION

ORDERING INFORMATIONModel 5SFT, 5SHT, 5RT, 5RBT, 5RL, 5RBL

ORDERING INFORMATION

SHT Case Style

SFT Case Style

NOTE: **Insert case style when ordering

RL Case Style

RBL Case Style

DRL Case Style

RT Case Style

RBT Case Style

Model 2S, 2R Model 2DRLCurrent Accuracy Burden Accuracy Burden

Catalog # Ratio @ 60 Hz VA@ 60 Hz @ 60 Hz VA @ 60 Hz2**-500 50:5 ±3% 2.0 ±2% 1.52**-600 60:5 ±2% 2.0 ±1% 2.52**-750 75:5 ±2% 2.0 ±1% 3.52**-800 80:5 ±2% 2.0 ±1% 4.02**-101 100:5 ±1% 2.0 ±1% 5.02**-121 120:5 ±1% 2.5 ±1% 5.02**-1250 125:5 ±1% 2.5 ±1% 5.02**-151 150:5 ±1% 4.0 ±1% 8.02**-201 200:5 ±1% 4.0 ±1% 10.02**-251 250:5 ±1% 6.0 ±1% 12.52**-301 300:5 ±1% 8.0 ±1% 15.02**-401 400:5 ±1% 10.0 ±1% 20.0

• Solid Core• 0.6kV Insulation Class,

BIL 10kV Full Wave• 50-400 Hz• 8-32 Studs or 24" Leads

See CT Application Note in Technical Reference Section.

93

TRAN

SDUC

ERS

/SE

NSO

RS

Page 6: Weschler DC Ammeter Shunts - Synergy Systems, Inc · Weschler DC Ammeter Shunts Type HA — 1 Through 500 Amperes Lightweight Types Type Lab — 10 Through 1000 Amperes Type MLC —

94

TRAN

SDUCER

S/S

ENSO

RS

Model 180RL, 180SHT, 181Current V.A. for

Ratio ±1% ANSI Metering Class @ 60 HzCatalog # Amperes Class B0.1 B0.2 B0.5 B0.9 B1.8180**-101 100:5 2.5 1.2 2.4 — — —180**-151 150:5 5.0 0.6 1.2 — — —180**-201 200:5 12.5 0.6 0.6 1.2 — —180**-251 250:5 12.5 0.3 0.3 1.2 — —180**-301 300:5 25.0 0.3 0.3 0.6 1.2 2.4180**-401 400:5 50.0 0.3 0.3 0.3 0.6 1.2180**-501 500:5 50.0 0.3 0.3 0.3 0.6 1.29180**-601 600:5 50.0 0.3 0.3 0.3 0.6 0.6180**-751 750:5 50.0 0.3 0.3 0.3 0.3 0.6180**-801 800:5 75.0 0.3 0.3 0.3 0.3 0.3180**-102 1000:5 100.0 0.3 0.3 0.3 0.6 0.6180**-122 1200:5 125.0 0.3 0.3 0.3 0.6 0.6180**-152 1500:5 160.0 0.3 0.3 0.3 0.3 0.3180**-162 1600:5 175.0 0.3 0.3 0.3 0.3 0.3

Current V.A. forRatio ±1% ANSI Metering Class @ 60 Hz

Catalog # Amperes Class B0.1 B0.2 B0.5 B0.9 B1.88**-201 200:5 5.0 1.2 1.2 — — —8**-251 250:5 7.5 0.6 1.2 2.4 — —8**-301 300:5 15.0 0.6 0.6 1.2 2.4 —8**-401 400:5 25.0 0.3 0.6 1.2 1.2 —8**-501 500:5 35.0 0.3 0.3 0.6 1.2 —8**-601 600:5 50.0 0.3 0.3 0.6 1.2 2.48**-751 750:5 50.0 0.3 0.3 0.3 0.6 1.28**-801 800:5 60.0 0.3 0.3 0.3 0.6 1.28**-102 1000:5 75.0 0.3 0.3 0.3 0.6 1.28**-122 1200:5 75.0 0.3 0.3 0.3 0.6 0.68**-152 1500:5 90.0 0.3 0.3 0.3 0.6 0.68**-162 1600:5 100.0 0.3 0.3 0.3 0.6 0.68**-202 2000:5 120.0 0.3 0.3 0.3 0.3 0.38**-252 2500:5 50.0 0.3 0.3 0.3 0.3 —8**-302 3000:5 60.0 0.3 0.3 0.3 0.3 —8**-352 3200:5 70.0 0.3 0.3 0.3 0.3 —8**-402 4000:5 80.0 0.3 0.3 0.3 0.3 —

Model 8SHT, 8RL

Model 170SHT, 170RL

ORDERING INFORMATIONModel 170 — Window Dia. 4.25"

Model 8 — Window Dia. 3.25"

Weschler AC Current Transformers

Model 180/181 — Window Dia. 2.5"

ORDERING INFORMATION

ORDERING INFORMATION

NOTE: **Insert case style when ordering

3P3

Current V.A. for

Ratio ±1% ANSI Metering Class @ 60 HzCatalog # Amperes Class B0.1 B0.2 B0.5 B0.9 B1.8

170**-201 200:5 5.0 1.2 1.2 — — —170**-251 250:5 5.0 1.2 1.2 — — —170**-301 300:5 12.5 0.6 0.6 1.2 2.4 —170**-401 400:5 25.0 0.6 0.6 1.2 1.2 2.4170**-501 500:5 25.0 0.3 0.3 0.6 1.2 2.4170**-601 600:5 25.0 0.3 0.3 0.6 0.6 1.2170**-751 750:5 40.0 0.3 0.3 0.3 0.3 0.6170**-801 800:5 50.0 0.3 0.3 0.3 0.3 0.6170**-102 1000:5 75.0 0.3 0.3 0.3 0.3 0.6170**-122 1200:5 100.0 0.3 0.3 0.3 0.3 0.6170**-152 1500:5 80.0 0.3 0.3 0.3 0.6 0.6170**-162 1600:5 90.0 0.3 0.3 0.3 0.6 0.6170**-202 2000:5 105.0 0.3 0.3 0.3 0.3 0.3170**-252 2500:5 130.0 0.3 0.3 0.3 0.3 0.3170**-302 3000:5 165.0 0.3 0.3 0.3 0.3 0.3170**-352 3200:5 190.0 0.3 0.3 0.3 0.3 0.3170**-402 4000:5 215.0 0.3 0.3 0.3 0.3 0.3

Model 3P4 — Window Dia. 1.56" Phase Center 3.56"

ORDERING INFORMATION

Current ANSI Metering Class @ 60 HzCatalog # Ratio B0.1 B0.2 B0.5 B0.9 B1.83P4–500 50:5 4.8 – – – –3P4–101 100:5 1.2 2.4 – – –3P4–151 150:5 0.6 1.2 2.4 – –3P4–201 200:5 0.6 0.6 1.2 2.4 –3P4–251 250:5 0.6 0.6 1.2 2.4 2.43P4–301 300:5 0.3 0.3 0.6 1.2 2.43P4–401 400:5 0.3 0.3 0.6 1.2 1.23P4–501 500:5 0.3 0.3 0.6 0.6 1.23P4–601 600:5 0.3 0.3 0.6 0.6 1.23P4–751 750:5 0.3 0.3 0.6 0.6 0.63P4–801 800:5 0.3 0.3 0.6 0.6 0.63P4–102 1000:5 0.3 0.3 0.3 0.6 0.6

Model 3P3 — Window Dia. 0.97" Phase Center 2.31"

ORDERING INFORMATION

Current Accuracy BurdenCatalog # Ratio @ 60 Hz VA@60Hz3P3–500 50:5 ±3% 2.03P3–600 60:5 ±2% 2.03P3–750 75:5 ±2% 2.03P3–800 80:5 ±2% 2.03P3–101 100:5 ±1% 2.03P3–121 120:5 ±1% 2.5

3P3–1250 125:5 ±1% 2.53P3–151 150:5 ±1% 4.03P3–201 200:5 ±1% 5.03P3–251 250:5 ±1% 7.53P3–301 300:5 ±1% 10.0

Page 7: Weschler DC Ammeter Shunts - Synergy Systems, Inc · Weschler DC Ammeter Shunts Type HA — 1 Through 500 Amperes Lightweight Types Type Lab — 10 Through 1000 Amperes Type MLC —

95

TRAN

SDUC

ERS

/SE

NSO

RS

Model Rated Current ConnectionsPCL-5 5A #8 screwsPCL-20 10A, 15A, 20A*PCL-75 25A, 50A, 75A*PCL-100 100A #8 studsPCL-150 150APCL-200 200APCL-300 300APCL-400 400APCL-600 600APCM-5 5A #10 screwsPCM-10 10APCM-20 20APCM-30 30APCM-50 50APCM-75 75APCM-100 100APCM-150 150APCM-200 200APCM-300 300A #8 studs*Switch selectable

Instrument TransformerAC Current Transducers• Large Window Area

• 4-20mA DC Output

• 0.5% FS accuracy

• 120VAC or 24VDC Power

The PCL is a 4 terminaldevice with separate connections for power and load. The PCM is atwo terminal device. 24V is applied betweenthe + terminal and ground.The output load may beinserted in either the – line for negative ground systems or the + line forpositive ground systems.

SPECIFICATIONSOutput Signal: Average responding, RMS calibratedLinear Range: 0-120% of rated current (typical)Frequency: 50/60HzOperating Temperature: -30 to 60°CInsulation Level: 600V, 10kV BIL full waveMaximum Output: 30mA DCOutput Ripple: 1% max peakSupply Voltage: PCL 120VAC ±10%

PCM 24VDC ±10%Output Load: PCL <1000 ohms

PCM <600 ohmsSize (LxWxH, inches) Window diaPCL-5 thru 75 2.7 x 2.4 x 4.5 0.94"PCL-100 & up 4.5 x 4.7 x 4.9 2.13"PCM-5 thru 20 2.7 x 2.4 x 2.75 0.93"PCM-30 & up 4.5 x 4.7 x 4.9 1.25"

ORDERING INFORMATION

NK TechnologiesGround Fault Sensor

SPECIFICATIONS

ORDERING INFORMATION

A B C D –– E––

• Fixed or selectable setpoint• Solid-state or relay output• Green LED Power-On indicationDetects ground fault (earth leakage) conditions by monitoring all current-carrying conductors in a grounded single or three phase system.

Setpoint: AG1, AG2: factory calibratedAG3: field jumper selected

Solid-state Output: Isolated dry contactAC Switch: 1A @ 240VACDC Switch: 0.15A @ 30VACLeakage <10 micro Amps (N.O.), <2.5mA (N.C.)

Mechanical Output: Single pole relayAuto Reset: SPDT, 1A @ 125VAC, 2A @ 30VDCLatching: SPST, 1A @ 125VAC, 2A @ 30VDC

Response Time: 200ms @ 5% above trip point60ms @ 50% above trip point15ms @ 500% above trip point

Isolation: 5kVAC (tested)Frequency: 50–400 Hz (monitored circuit)Power Supply: 66-132VAC

19.2-28.8VAC/DCLoading: 2VA max.Case: UL94 V0 Flammability RatedEnvironment: -4 to 122°F (-20 to 50°C), < 95% RH, non-condensingSize: 3.9"W x 3.0"H x 1.5"D (99x76x38mm)Listings: UL 1053, Class 1 Recognized, CE

To Order Insert Code for Each Letter to Select Catalog Number

AG AA SSeettppooiinntt

1 5–100mA factory set2* 80–950mA factory set3 5/10/30mA jumper set (TR3 only)

BB OOuuttppuutt TTyyppeeNOAC Normally Open solid state, 1A @ 240VACNCAC Normally Closed solid state, 1A @ 240VACNODC Normally Open solid state, 0.15A @ 30VDCNCDC Normally Closed solid state, 0.15A @ 30VDCNCR1 Normally Closed SPST Relay (requires LA option)NOR1 Normally Open SPST Relay (requires LA option)SDT1 SPDT Relay (Form C) with autoreset (requires DEN or ENE option)

CC PPoowweerr SSuuppppllyy120 120VAC24U* 24VAC/VDC

DD OOppttiioonnssFS Normally Energized (solid state output only)NF Normally De-energized (solid state output only)ENE Normally Energized, auto-reset (SDT1 output only)DEN Normally De-energized, autoreset (SDT1 output only)LA Latching (NOR1 and NCR1)

EE SSeettppooiinnttTR3 Tri-set (5/10/30mA)nnn Factory set trip point in mA

*Not UL recognized.

Example: AG1-NOAC-120-FS-005

NEW

Page 8: Weschler DC Ammeter Shunts - Synergy Systems, Inc · Weschler DC Ammeter Shunts Type HA — 1 Through 500 Amperes Lightweight Types Type Lab — 10 Through 1000 Amperes Type MLC —

96

TRAN

SDUCER

S/S

ENSO

RS

Frequency Input Output Part # ±1.0% Part # ±0.1%45-55 Hz 120V 0-1 mA FQA050J FQA050Z45-65 Hz 120V 0-1 mA FQA055J FQA055Z55-65 Hz 120V 0-1 mA FQA060J FQA060Z375-425 Hz 120V 0-1 mA FQA400J FQA400Z45-55 Hz 120V 4-12-20 mADC FQD050J FQD050Z*45-65 Hz 120V 4-12-20 mADC FQD055J FQD055Z*55-65 Hz 120V 4-12-20 mADC FQD060J FQD060Z*375-425 Hz 120V 4-12-20 mADC FQD400J FQD400Z*

Transducer Type Input Output Aux. Power Can Size Part # ±0.5% Part # ±0.2%Single (average sensing) 0–150 VAC 0–1 mADC None 1 ETA150JA ETA150ZASingle (average sensing) 0–300 VAC 0–1 mADC None 1 ETA300JA ETA300ZASingle (average sensing) 0–600 VAC 0–1 mADC None 1 ETA600JA ETA600ZASingle (average sensing) 0–150 VAC 4 mA–20 mADC 120 VAC 2 ETD150JA ETD150ZASingle (average sensing) 0–300 VAC 4 mA–20 mADC 120 VAC 2 ETD300JA ETD300ZASingle (average sensing) 0–600 VAC 4 mA–20 mADC 120 VAC 2 ETD600JA ETD600ZA3 Inputs (average sensing) 0–150 VAC 0–1 mADC None 2 ETA153JA ETA153ZA3 Inputs (average sensing) 0–300 VAC 0–1 mADC None 2 ETA303JA ETA303ZASingle (TRMS sensing) 0–150 VAC 0–1 mADC 120 VAC 2 ETA150JT ETA150ZTSingle (TRMS sensing) 0–300 VAC 0–1 mADC 120 VAC 2 ETA300JT ETA300ZTSingle (TRMS sensing) 0–150 VAC 4 mA–20 mADC 120 VAC 2 ETD150JT ETD150ZTSingle (TRMS sensing) 0–300 VAC 4 mA–20 mADC 120 VAC 2 ETD300JT ETD300ZT

Transducer Type Input Output Aux. Power Can Size Part # ±0.5% Part # ±0.2%Single (average sensing) 0–1 AAC 0–1 mADC None 1 CTA100JA CTA100ZASingle (average sensing) 0–1 AAC 4 mA–20 mADC 120 VAC 2 CTD100JA CTD100ZASingle (TRMS sensing) 0–1 AAC 0–1 mADC 120 VAC 2 CTA100JT CTA100ZTSingle (TRMS sensing) 0–1 AAC 4 mA–20 mADC 120 VAC 2 CTD100JT CTD100ZTSingle (average sensing) 0–5 AAC 0–1 mADC None 1 CTA500JA CTA500ZASingle (average sensing) 0–5 AAC 4 mA–20 mADC 120 VAC 2 CTD500JA CTD500ZATriple (average sensing) 0–5 AAC 0–1 mADC None 2 CTA503JA CTA503ZASingle (TRMS sensing) 0–5 AAC 0–1 mADC 120 VAC 2 CTA500JT CTA500ZTSingle (TRMS sensing) 0–5 AAC 4 mA–20 mADC 120 VAC 2 CTD500JT CTD500ZT

AC CURRENT TRANSDUCER

Weschler Transducers

• Accuracy: ±0.2% or 0.5%

• Wide Variety of Input and Output Options

• Rugged Metal Can Construction

• 5 kV Transient Protection

• Sizes:

Can size 1: 3.976" L x 2.012" W x 4.096" H

Can size 2: 5.236" L x 3.769" W x 4.717" H

CLD001J

AC VOLTAGE TRANSDUCER

AC FREQUENCY TRANSDUCER—CAN SIZE “2”

AC & DC Transducers—Metal Case

*Accuracy is 0.2%

Specifications on PAGE 98.

Specifications on PAGE 98.

Specifications on PAGE 98.

Page 9: Weschler DC Ammeter Shunts - Synergy Systems, Inc · Weschler DC Ammeter Shunts Type HA — 1 Through 500 Amperes Lightweight Types Type Lab — 10 Through 1000 Amperes Type MLC —

97

Connection Phase Angle Output Part # ±2° Part # ±1°1 ø 2-wire 60°–0–60° 1–0–1 mADC PAB010J PAB010Z3 ø 3-wire 60°–0–60° 1–0–1 mADC PAB020J PAB020Z3 ø 4-wire 60°–0–60° 1–0–1 mADC PAB030J PAB030Z1 ø 2-wire 60°–0–60° 4–12–20 mADC PAF010J PAF010Z3 ø 3-wire 60°–0–60° 4–12–20 mADC PAF020J PAF020Z3 ø 4-wire 60°–0–60° 4–12–20 mADC PAF030J PAF030Z

NOTE: Also available in plastic foot-mounted or DIN rail.For ranges not listed, contact Weschler.

Connection Lag—Lead Output Part # STD TC Part # Low TC1 ø 2-wire -0.5 to 1.0 to +0.5 1–0–1 mADC PFB010J PFB010Z3 ø 3-wire -0.5 to 1.0 to +0.5 1–0–1 mADC PFB020J PFB020Z3 ø 4-wire -0.5 to 1.0 to +0.5 1–0–1 mADC PFB030J PFB030Z1 ø 2-wire -0.5 to 1.0 to +0.5 4 –12–20 mADC PFF010J PFF010Z3 ø 3-wire -0.5 to 1.0 to +0.5 4 –12–20 mADC PFF020J PFF020Z3 ø 4-wire -0.5 to 1.0 to +0.5 4 –12–20 mADC PFF030J PFF030Z

Connection No. of Elements Rating Output Part # ±0.5% Part # ±0.2%1 ø 2-wire 1 element 120V/5A ±1 mADC x 2 WVB010J WVB010Z3 ø 3-wire 2 element 120V/5A ±1 mADC x 2 WVB020J WVB020Z3 ø 4-wire 21/2 element 120V/5A ±1 mADC x 2 WVB025J WVB025Z3 ø 4-wire 3 element 120V/5A ±1 mADC x 2 WVB030J WVB030Z1 ø 2-wire 1 element 120V/5A W: 4–20mA, VAR: 4-12–20 mA WVD010J WVD010Z3 ø 3-wire 2 element 120V/5A W: 4–20mA, VAR: 4-12–20 mA WVD020J WVD020Z3 ø 4-wire 21/2 element 120V/5A W: 4–20mA, VAR: 4-12–20 mA WVD025J WVD025Z3 ø 4-wire 3 element 120V/5A W: 4–20mA, VAR: 4-12–20 mA WVD030J WVD030Z

Connection No. of Elements Rating Output Aux. Power Part # ±0.5% Part # ±0.2%1 ø 2-wire 1 element 120V/5A ±1 mADC None VTB010J VTB010Z3 ø 3-wire 2 element 120V/5A ±1 mADC None VTB020J VTB020Z3 ø 4-wire 21/2 element 120V/5A ±1 mADC None VTB025J VTB025Z3 ø 4-wire 3 element 120V/5A ±1 mADC None VTB030J VTB030Z1 ø 2-wire 1 element 120V/5A 4-12–20 mADC None VTD010J VTD010Z3 ø 3-wire 2 element 120V/5A 4-12–20 mADC None VTD020J VTD020Z3 ø 4-wire 21/2 element 120V/5A 4-12–20 mADC None VTD025J VTD025Z3 ø 4-wire 3 element 120V/5A 4-12–20 mADC None VTD030J VTD030Z

Connection No. of Elements Rating Output Aux. Power Part # ±0.5% Part # ±0.2%1 ø 2-wire 1 element 120V/5A ±1 mADC None WTB010J WTB010Z3 ø 3-wire 2 element 120V/5A ±1 mADC None WTB020J WTB020Z3 ø 4-wire 21/2 element 120V/5A ±1 mADC None WTB025J WTB025Z3 ø 4-wire 3 element 120V/5A ±1 mADC None WTB030J WTB030Z1 ø 2-wire 1 element 120V/5A 4 mA–20 mADC None WTD010J WTD010Z3 ø 3-wire 2 element 120V/5A 4 mA–20 mADC None WTD020J WTD020Z3 ø 4-wire 21/2 element 120V/5A 4 mA–20 mADC None WTD025J WTD025Z3 ø 4-wire 3 element 120V/5A 4 mA–20 mADC None WTD030J WTD030Z

Weschler TransducersAC WATT TRANSDUCER—CAN SIZE "2"

AC VAR TRANSDUCER—CAN SIZE "2"

AC WATT/VAR TRANSDUCER—CAN SIZE "2"

AC POWER FACTOR—CAN SIZE "2"

AC PHASE ANGLE—CAN SIZE "2"

TRAN

SDUC

ERS

/SE

NSO

RS

Page 10: Weschler DC Ammeter Shunts - Synergy Systems, Inc · Weschler DC Ammeter Shunts Type HA — 1 Through 500 Amperes Lightweight Types Type Lab — 10 Through 1000 Amperes Type MLC —

98

TRAN

SDUCER

S/S

ENSO

RS

Weschler TransducersSPECIFICATIONS - ALL AC MODELS

Input Burden <1 mAOutput Compliance 10VDCAccuracy (>10% of range) ±0.5% of FS Response Time 500ms (0-99%)Calibration Adjustments ±5% (zero & FS)Temperature Range 0-40°C, 20-90% RH non-condensingIsolation 2600VAC input to output, power & case

1000VAC aux power to output & case1000VAC output to case

Surge Withstand IEEE472/ANSI C37.90.1-1989 SWCAuxiliary Power 120VAC ±10%, 2VA

Input Output Aux. Power Case Size Part #0-1mADC 4-20mADC 120VAC 2 CLD001J0-1mADC 0-1mADC 120VAC 2 CLD002J0-1mADC 0-10VDC 120VAC 2 CLD003J0-50mVDC 4-20mADC 120VAC 2 CLD101J0-50mVDC 0-1mADC 120VAC 2 CLD102J0-50mVDC 0-10VDC 120VAC 2 CLD103J

Output 0-1 or ±1mADC into 10kΩ max., 10VDC compliance4-20mADC into 750Ω max., 15VDC compliance

Response Time <400ms (0-99% of output)Output Ripple 0.5% of span, peak-to-peak maxIsolation 2500VAC input to output, power & case

2000VAC aux. power to output & case500VAC output to case

External Span Adjustment Zero: ±1% min; Span: ±2% minSurge Withstand IEEE472/ANSI C37.90.1-1989, JIS C111 (5kV, 1.2 x 50µs)Insulation Resistance >10MΩ@500VDC input/output/power/caseOperating Temperature -20°C to 60°C; 0-90% RH non-condensing

AC CURRENT & VOLTAGE TRANSDUCERSCurrent Models

Input Burden <0.2VAOverrange 200% of rated input continuous;

1000% of rated input for 5 secVoltage Models

Input Burden 150VAC: <0.8VA; 300 VAC: <1.6VA (TRMS)150VAC: <1.8VA; 300 VAC: <3.6VA (Avg. Sensing)

Overrange 120% of rated input continuousTemperature Drift ±250ppm/°C of span, 0.5% models

±140ppm/°C of span, 0.2% modelsOptions (specify when ordering)50Hz, 50/60Hz or 400Hz operation (60Hz standard)230VAC, 24VDC* or 48VDC* Auxiliary Power (*average sensing models only)

AC WATT & VAR TRANSDUCERSInput Burden Voltage: <0.5VA per element @120V

Current: <0.2VA per elementVoltage Input Range 100-135VAC, input powered 0.5% models

85-135VAC, input powered 0.2% models0-120% of rated input, auxiliary powered models

Voltage Overrange 150% of rated input continuous (aux. powered only)Current Input Range 10-200% of rated input with accuracyCurrent Overrange 200% continuous, 1000% for 5 secondsOutput Calibration 120VAC/1A = 0-100 watts/element

120VAC/5A = 0-500 watts/elementTemperature Drift ±250ppm/°C of span, 0.5% models

±80ppm/°C of span, 0.2% modelsInfluences (% of span) <0.5% for PF, phase interaction or current imbalance

COMBINED AC WATT/VAR TRANSDUCERSInput Burden Voltage: <0.5VA per element

Current: <0.2VA per elementVoltage Input Range 100-135VAC, input powered 0.5% models

85-135VAC, input powered 0.2% models0-120% of rated input, auxiliary powered models

Voltage Overrange 150% of rated input continuous (aux. powered only)Current Input Range 10-200% of rated input with accuracy Current Overrange 200% continuous, 1000% for 5 secondsTemperature Drift ±250ppm/°C of span, 0.5% models

±80ppm/°C of span, 0.2% modelsInfluences (% of span) <0.5% for PF, phase interaction or current imbalance

Options for Watt, VAR & Watt/VAR Models50Hz or 400Hz operation (60Hz standard)1AAC Current Rated240VAC Voltage Rated480 VAC Voltage Rated (not available on 0.2% units)120VAC, 240VAC, 24VDC or 48VDC Auxiliary PowerSpecial Calibration to Customer PT & CT

POWER FACTOR TRANSDUCERS

Specifications same as Combined Watt/VAR Models except:Accuracy ±0.01 power factor Temperature Drift ±500ppm/°C of span, suffix J models

±150ppm/°C of span, suffix Z modelsLow Current Detect <4%Influences (% of span) <1% for voltage, <2% for current

Options for PF Models1 AAC Current Rated120VAC, 240VAC, 24VDC or 48VDC Auxiliary Power

AC PHASE ANGLE TRANSDUCERS

Specifications same as Combined Watt/VAR Models except:Temperature Drift ±500ppm/°C of span, suffix J models

±80ppm/°C of span, suffix Z modelsInfluences <0.5° for voltage, <1° for current

Options for Phase Angle Models50Hz or 400Hz operation (60Hz standard)1AAC Current Rated120VAC, 240VAC, 24VDC or 48VDC Auxiliary PowerFull Scale = Lagging Phase Angle±90° Phase Angle

FREQUENCY TRANSDUCER

Input Burden <0.1VA @120VVoltage Input Range 100-135VAC, input powered models

±20% of rated voltage, aux. powered models Temperature Drift ±250ppm/°C of span, suffix J models

±50ppm/°C of span, suffix Z modelsHarmonics Fundamental through 9th harmonic

Options for Frequency Models240 Volt Input24VDC or 48VDC Aux. Power (0.2% models only)1-0-1 mADC Output

DC TO DC ISOLATION TRANSDUCERS

DC TO DC ORDERING INFO

Page 11: Weschler DC Ammeter Shunts - Synergy Systems, Inc · Weschler DC Ammeter Shunts Type HA — 1 Through 500 Amperes Lightweight Types Type Lab — 10 Through 1000 Amperes Type MLC —

99

Output Signal: 4–20 mA, Loop-Powered, True RMS

Output Limit: 23 mA

Accuracy: 0.8% FS (1.0% on ATR3 & 4)

Frequency Range: 10–400 Hz

Power Supply: 24VDC Nom., 40 VDC Max., 120 VAC

Isolation Voltage: UL Listed to 1270 VAC, Tested to 5 kV

(600 VAC on ATR3 & 4)

Sensing Aperture: -FT Models: 0.75" (19 mm) Dia.

-FL Models: 3.0" (76 mm) Dia.

-SP Models: 0.85" (21.5 mm) Sq.

Case: UL 94V-0 Flammability Rated

Environmental: -4 to 122˚F (-20 to 50˚C),

0–95% RH, Non-Condensing

Listings: UL 508 Industrial Control Equipment

(USA and Canada)

Loading (All Models)

Loop Power: RL <500Ω

External Power: RL >50kΩ

Self Powered: Accuracy for RL >1ΜΩ,

add 1.3% for RL = 100 kΩ

-005 Models -010 Models -420 ModelsOutput Signal: 0–5 VDC 0–10 VDC 4–20 mAOutput Limit: 10 VDC 15 VDC 40 mAAccuracy: 1.0% FS 1.0% FS 0.5% FSFrequency Range: 50–60 Hz 50–60 Hz 20–100 HzPower Supply: Self or External Self or External Loop or ExternalIsolation Voltage: UL Listed to 1270 VAC, Tested to 5 kVSensing Aperture: -FF Case: 0.55" (14 mm) Diameter

-FT Case: 0.75" (19 mm) Diameter-SP Case: 0.85" (21.5 mm) Sq.

Case: UL 94V-0 Flammability RatedEnvironmental: -4 to 122˚F (-20 to 50˚C), 0–95% RH, Non-CondensingListings: UL 508 Industrial Control Equipment (USA and Canada), CE

AT & ATP SPECIFICATIONS

NK Technologies AC Current Transducers

FL Style Case

AT and ATP current transducers combine a current transformerand signal conditioner in a single package. These transducersoffer jumper selected current input ranges with proportionalindustry standard 4-20 mA, 0-5 VDC and 0-10 VDC outputs.The AT and ATP series are designed for application on “linear”or sinusoidal AC loads. Available in a split core or two types of solid core cases.

ATR and ATPR transducers combine a currenttransformer and True RMS signal conditioner in a single package. The ATR and ATPR series provide True RMS outputs on distortedwaveforms found on VFD and SCR outputs or on linear loads in “noisy” power environments.Available in a solid or split core case.

ATR & ATPR SPECIFICATIONS

FT Case Style

SP Case Style

FF Case Style

A ModelAT Average sensing, loop or self-powered

B Input Ranges0 0–2/5A1 0–10/20/50A2 0–100/150/200A3 0–375/500/750A4 0–1000/1333/2000A

C Output420 4–20mA005 0–5 VDC (0,1,2 only)010 0–10 VDC (0,1,2 only)

D Power24L 24 VDC Loop Powered (4–20mA only)000 Self powered (DC output only)

E CaseFF Fixed core, front terminals (0,1,2 only)FT Fixed core, top terminals (0,1,2 only)SP Split coreFL Fixed core (3 & 4 only)

A ModelATP Average sensing, ext. poweredATPR True RMS sensing, ext. powered

B Input Ranges0 0–2/5A (ATP only)1 0–10/20/50A (ATP only)2 0–100/150/200A (ATP only)3 0–375/500/750A4 0–1000/2000A

C Output420 4–20mA005 0–5 VDC010 0–10 VDC

D Power24U 24V AC/DC, isolated output120 120VAC

E CaseFF Fixed core, front terminals (0,1,2 only)FL Fixed core (3 & 4 only)SP Split core (0,1,2 only)

A ModelATR TRMS sensing, loop powered

B Input3 0–375/500/750A4 0–1000/1333/2000

C Output420 4–20mA

D Power24L 24VDC, loop powered

E CaseFL Fixed core

ORDERING INFORMATION

TRAN

SDUC

ERS

/SE

NSO

RS

Page 12: Weschler DC Ammeter Shunts - Synergy Systems, Inc · Weschler DC Ammeter Shunts Type HA — 1 Through 500 Amperes Lightweight Types Type Lab — 10 Through 1000 Amperes Type MLC —

100

TRAN

SDUCER

S/S

ENSO

RS

Input Frequency Output Catalog Number120 VAC 45–55 Hz 0–1 mADC 253-THZU-PQFA-AG120 VAC 55–65 Hz 0–1 mADC 253-THZU-PQFA-AN120 VAC 45–65 Hz 0–1 mADC 253-THZU-PQFA-AJ120 VAC 360–440 Hz 0–1 mADC 253-THZU-PQFA-BI

Input Auxiliary Power Output Catalog Number AC Voltage—Average Sensing, Single-Phase120 VAC/60 Hz Self 0–1 mADC 253-TVAU-PQFA-C6120 VAC/60 Hz 120 VAC 4–20 mADC 253-TVLU-PQHG-C6-DGAC Voltage—True RMS Sensing, Single-Phase 120 VAC/60 Hz 120 VAC 0–1 mADC 253-TVRU-PQFA-C6-DGAC Voltage—True RMS Sensing, 3-Phase, 3 DC Outputs120 VAC/60 Hz 120 VAC 0–1 mADC 256-TVRU-PQFA-C6-DGInput System Output Catalog NumberAC Voltage—Average Sensing, 3-Phase, 3 DC Outputs120 VAC/60 Hz 3-Phase, 3-Wire 4–20 mADC 256-TVLU-PQHG-C6-DG120 VAC/60 Hz 3-Phase, 4-Wire 0–1 mADC 256-TVSU-PQFA-C6-DGInput Auxiliary Power Output Catalog NumberAC Voltage—Suppressed Zero AC, Expanded Scale 108–132 VAC Self 0–1 mADC 253-TVZU-A9FA-C6

Input Auxiliary Power Output Catalog Number AC Current—Average Sensing, Single-Phase 5A AC/60 Hz Self 0–1 mADC 253-TAAU-LSFA-C6

5A AC/60 Hz 120 VAC 4–20 mADC 253-TALU-LSHG-C6-DG AC Current—Average Sensing, 3-Phase, 3 DC Outputs 5A AC/60 Hz 120 VAC 0–1 mADC 256-TASU-LSFA-C6-DG

5A AC/60 Hz 120 VAC 4–20 mADC 256-TALU-LSHG-C6-DG AC Current—True RMS Sensing, Single-Phase 5A AC/60 Hz 120 VAC 0–1 mADC 253-TARU-LSFA-C6-DGAC Current—True RMS Sensing, 3-Phase, 3 DC Outputs 5A AC/60 Hz 120 VAC 0–1 mADC 256-TARU-LSFA-C6-DG AC Current—Bi-Directional 5A AC/60 Hz Self (120 VAC) ±1 mADC 256-TABU-LSM1-C6-PQ-T3

AC CURRENT

Crompton AC Current and Voltage Transducers

• CE Compliant (CE Marked)

• Flexible Design with up to Three Transducers in One Housing

• UL Approved

• Enclosure to IEC529 (IP50)

• Flame Retardant

• 35 mm DIN Rail Mount or Key Hole Slots

AC Current, Voltage, Frequency and DC• Average Sensing and True RMS

• Self Powered and Auxiliary

• Current Measuring to 0.5% Accuracy

• Isolated Input and Output

253

AC VOLTAGE

FREQUENCY

Page 13: Weschler DC Ammeter Shunts - Synergy Systems, Inc · Weschler DC Ammeter Shunts Type HA — 1 Through 500 Amperes Lightweight Types Type Lab — 10 Through 1000 Amperes Type MLC —

101

TRAN

SDUC

ERS

/SE

NSO

RS

Input Auxiliary Power Output Catalog Number

DC Current 120 VAC 0–1 mADC 256-TTAU-**FA-DG

DC Millivolts 120 VAC 0–1 mADC 256-TTMU-**FA-DG

DC Voltage 120 VAC 0–1 mADC 256-TTVU-**FA-DG

K Thermocouple 120 VAC 0–1 mADC 256-TTNU-KTFA-DG

T Thermocouple 120 VAC 0–1 mADC 256-TTCU-TTFA-DG

J Thermocouple 120 VAC 0–1 mADC 256-TTFU-JTFA-DG

Crompton Transducers

DC/DC & TEMPERATURE

AC POWER

AC Power Transducers• Wide Range of Transducers to Measure All Forms of Power

• Available in Single-Phase, 3-Phase 3- or 4-Wire

• Self Powered Units Permit Voltage Variations Up to 20% of Nominal Input

• Measures both Import and Export Power

• Accuracy Class 0.5

System Input Type Output Catalog Number

AC Watts (Active Power)

1 Ph, 2 Wire 120V/5A 1 Element 0-1 mADC 256-TWKU-QQFA-C6-**

1 Ph, 3 Wire 240V/10A 1 Element 0-1 mADC 256-TWKU-Q8FA-C6-**

3 Ph, 3 Wire 120V/5A 2 Element 0-1 mADC 256-TWMU-QQFA-C6-**

3 Ph, 4 Wire 120V/5A 2 1/2 Element 0-1 mADC 256-TWNU-QQFA-C6-**

** Specify Range

AC VARS (Reactive Power)

1 Ph, 2 Wire 120V/5A 1 Element 0-1 mADC 256-TXKU-QQFA-C6-**

1 Ph, 3 Wire 240V/10A 1 Element 0-1 mADC 256-TXKU-Q8FA-C6-**

3 Ph, 3 Wire 120V/5A 2 Element 0-1 mADC 256-TXMU-QQFA-C6-**

3 Ph, 4 Wire 120V/5A 2 1/2 Element 0-1 mADC 256-TXNU-QQFA-C6-**

** Specify Range

AC VA (Apparent Power)

1 Ph, 3 Wire 120V/10A 1 Element 0-1 mADC 256-TYKU-QQFA-C6-**

3 Ph, 3 Wire 120V/5A 2 Element 0-1 mADC 256-TYMU-QQFA-C6-**

3 Ph, 4 Wire 120V/5A 2 1/2 Element 0-1 mADC 256-TYNU-QQFA-C6-**

** Specify Range

Power Factor (Suits Analog Meters) - Accuracy Class 0.2

1 Ph, 2 Wire 120V/5A 0-1-0 1-0-1 mADC 256-XFSU-QQFA-C3-Z1-DG

1 Ph, 2 Wire 120V/5A 1-0-1-0-1 1-0-1 mADC 256-XFAU-QQFA-C3-E4-DG

3 Ph, 3 Wire 120V/5A 0-1-0 1-0-1 mADC 256-XFWV-QQFA-C3-Z1-DG

3 Ph, 3 Wire 120V/5A 1-0-1-0-1 1-0-1 mADC 256-XFGU-QQFA-C3-E4-DG

3 Ph, 4 Wire 120V/5A 0-1-0 1-0-1 mADC 256-XFVU-QQFA-C3-Z1-DG

3 Ph, 4 Wire 120V/5A 1-0-1-0-1 1-0-1 mADC 256-XFDU-QQFA-C3-E4-DG

Page 14: Weschler DC Ammeter Shunts - Synergy Systems, Inc · Weschler DC Ammeter Shunts Type HA — 1 Through 500 Amperes Lightweight Types Type Lab — 10 Through 1000 Amperes Type MLC —

102

TRAN

SDUCER

S/S

ENSO

RS

IInnppuutt VVoollttaaggee CCuurrrreennttMax Continuous: 120% nominal 120% nominalMax Short Duration: 2x for 1 sec. 20x for 1 sec.Burden: < 0.2 VA < 0.6 VA

PT Ratio (primary): up to 400kV **CT Primary: 9999:5A **OOuuttppuuttss

RS485: Two wire half duplexBaud Rate: 2400, 4800, 9600, 19200Pulsed: Clean contact SPNO, 100V DC 0.5A maxPulse Duration: 60, 100 or 200 milliseconds

AAuuxxiilliiaarryy SSuuppppllyyAC/DC: 85-287 V AC / 85-312 V DC Absolute,45-66 HzDC: 10.2-60 V DC AbsoluteSupply Burden: 6VA

MMeeaassuurriinngg RRaannggeessVoltage: 80-120% of nominal (functional 5-120%)Current: 5-120% of nominal Frequency: 45-66HzPower Factor: 0.8 capacitive to 0.8 inductiveTHD: Up to 31st harmonic 0% - 40%Energy: 7 digit resolution

AAccccuurraaccyyVoltage, Current: ±0.17% of rangeFrequency: 0.15% of mid frequencyPower: ±0.2% of rangePower Factor: 1% of unityReactive Power (VAr): ±0.5% of rangeApparent Power (VA): ±0.2% of rangeTHD: ±1%Neutral Current: ±0.95% of rangeEnergy: KWh 1% IEC1036KVArh: 2%Analog Output: ±0.2%

Operating Temperature: -20 to +60°C, <90% RHEnclosure Polycarbonate

DIN Transducer: 5.5"H x 3.72"W x 3.72"D (140 x 95 x 95mm)Base Mount Transducer: 5.2"H x 3.74"W x 5.24"D (132 x 95 x 134mm)Display: 4.31"H x 4.31"W x 2.9"D(110 x 110 x 74mm)Panel Cut Out (Display): 4.06" (103mm) diameter, 4 studs

** 360MW max at 120% of relevant input

INT-

AA MMooddeell1561 single phase 5A CT input, DIN Rail1562 single phase 3 wire 5A CT input, DIN Rail1563 3 phase 3 wire 5A CT input, DIN Rail1564 3 phase 4 wire 5A CT input, DIN Rail1581 single phase 5A CT input, Base mount1582 single phase 3 wire 5A CT input, Base mount1583 3 phase 3 wire 5A CT input, Base mount1584 3 phase 4 wire 5A CT input, Base mount

BB IInnppuutt VVoollttaaggee L 57.7 – 139V L-N (1561 & 1581)

114 - 278 V L-L, 57.7 – 139V L-N (1562 & 1582)100 – 240 V L-L, 57.7 – 139V L-N (1563,4 & 1583,4)

M 140 – 277 V L-N (1561 & 1581)279 – 480 V L-L, 140 – 240V L-N (1562 & 1582)241 – 480 V L-L, 140 – 277V L-N (1563,4 & 1583,4)

CC IInnppuutt CCuurrrreenntt5 5A (CT secondary)

DD AAuuxxiilliiaarryy SSuuppppllyy L 12 – 48V DCM 100 – 250V AC/DC

EE CCoommmmuunniiccaattiioonnss OOppttiioonnss010 1 Modbus012 1 Modbus, 2 analog013 1 Modbus, 3 analog014 1 Modbus, 4 analog110 1 pulse/relay, 1 Modbus112 1 pulse/relay, 1 Modbus, 2 analog113 1 pulse/relay, 1 Modbus, 3 analog114 1 pulse/relay, 1 Modbus, 4 analog210 2 pulse/relay, 1 Modbus212 2 pulse/relay, 1 Modbus, 2 analog410 4 pulse/relay, 1 Modbus 412 4 pulse/relay, 1 Modbus, 2 analog610 6 pulse/relay, 1 Modbus612 6 pulse/relay, 1 Modbus, 2 analog

FF AAnnaalloogg OOuuttppuutt RRaannggee 0 No output1 0-20 mA, 10V compliance, user configurable as 4-20 mA

(3 channels max)2 0-1 mA, 10V compliance3 -1/0/+1 mA, 10V compliance4 0-5 mA, 10V compliance6 0-10 mA, 10V compliance

• Replaces multiple single function transducers• Measures up to 50 electrical parameters• True 3 and 4 wire measurement• Power, energy & power quality data• Pulsed, analogue and digital outputs• Programmable VT and CT ratios• Local or remote configuration & monitoring• DIN rail or base mounted styles

Up to 50 electrical and power quality parameters can be measuredand communicated into building management systems or viewedthrough the PC configuration software.

These transducers can be programmed using the configuration software or the optional Integra display unit. The display unit can be permanently mounted near the transducer, or connected whenconfiguration or status information is required.

Crompton Power & Energy Transducer Systems

ORDERING INFORMATION

SPECIFICATIONS

A B C D–– – E– F–

To Order: Insert Code for Each Letter to Select Catalog Number.Example INT-1563-M-5-M-013-1

1560

Page 15: Weschler DC Ammeter Shunts - Synergy Systems, Inc · Weschler DC Ammeter Shunts Type HA — 1 Through 500 Amperes Lightweight Types Type Lab — 10 Through 1000 Amperes Type MLC —

103

TRAN

SDUC

ERS

/SE

NSO

RS

Veris Split Core KW Transducers

Input Primary Voltage 208-480VAC rms, 50/60HzNumber of Phases Monitored One or ThreeInternal Isolation 2000VAC rmsInsulation Class 600VAC rmsTemperature Range 0 to 60°C, 50°C for 2400AHumidity Range 0 to 95% non-condensingAccuracy ±1%Output 4-20mASupply Power (current loop) 9-30VDC; 30mA max.CT Opening Small 1.5" x 1.25" (38x32mm)

Medium 2.9" x 2.45" (73x62mm)Large 5.5" x 2.45" (140 x 62mm)

Models with Modbus and Pulse Outputs also available.

Single CT Models for Use w/ Balanced 3Ø Loads or 1Ø 2 Wire InstallationsMax.

Model Voltage Amps CT SizeVE/H8041-0100-2 208/240 100 smallVE/H8041-0300-2 208/240 300 smallVE/H8041-0400-3 208/240 400 mediumVE/H8041-0800-3 208/240 800 mediumVE/H8041-0800-4 208/240 800 largeVE/H8041-1600-4 208/240 1600 largeVE/H8041-2400-4 208/240 2400 largeVE/H8042-0100-2 480 100 smallVE/H8042-0300-2 480 300 smallVE/H8042-0400-3 480 400 mediumVE/H8042-0800-3 480 800 mediumVE/H8042-0800-4 480 800 largeVE/H8042-1600-4 480 1600 largeVE/H8042-2400-4 480 2400 large

Three CT Models for Use with Any 3Ø Load or 1Ø 3 Wire InstallationsMax.

Model Voltage Amps CT SizeVE/H8043-0100-2 208 100 smallVE/H8043-0300-2 208 300 smallVE/H8043-0400-3 208 400 mediumVE/H8043-0800-3 208 800 mediumVE/H8043-0800-4 208 800 largeVE/H8043-4600-4 208 1600 largeVE/H8043-2400-4 208 2400 largeVE/H8044-0100-2 480 100 smallVE/H8044-0300-2 480 300 smallVE/H8044-0400-3 480 400 mediumVE/H8044-0800-3 480 800 mediumVE/H8044-0800-4 480 800 largeVE/H8044-1600-4 480 1600 largeVE/H8044-2400-4 480 2400 large

ORDERING INFORMATION

SPECIFICATIONS

Current Range: 1-135ASensor Power: InducedInsulation Class: 600VAC rmsFrequency Range: 50/60Hz.Temperature Range: -15° to 60°CHumidity Range: 0-95% non-condensingSetpoint Adjustable: 1-135AHysteresis: 10% TypicalDimensions: 2.95" x 2.68" x 1.04"Sensor Opening: 0.75" (19mm) Dia.

SPECIFICATIONS

Model Relay Contacts* Coil Solid State OutputVE/H735 Form A (SPST) 5(3)A@250VAC, 30VDC, 1/6HP 24VAC/DC 10mA 0.1A@30VAC/DC N.O. VE/H738 Form A (SPST) 10(5)A@250VAC, 30VDC, 1/3HP 24VAC/DC 10mA 1.0A@30VAC/DC N.O. VE/H739 Form A (SPST) 10(5)A@250VAC, 30VDC, 1/3HP 24VAC/DC 10mA 0.2A@120VAC/DC N.O. VE/H748 Form C (SPDT) 8(3.5)A@250VAC, 30VDC, 1/4HP 24VAC/DC 10mA 1.0A@30VAC/DC N.O. VE/H749 Form C (SPDT) 8(3.5)A@250VAC, 30VDC, 1/4HP 24VAC/DC 10mA 0.2A@120VAC/DC N.O. VE/H758 Form A (SPST) 10(5)A@250VAC, 30VDC, 1/3HP 9-12VDC 10mA 1.0A@30VAC/DC N.O. VE/H759 Form A (SPST) 10(5)A@250VAC, 30VDC, 1/3HP 9-12VDC 10mA 0.2A@120VAC/DC N.O. * Resistive load (inductive load). Also available in split core style (H930 series)

ORDERING INFORMATION

®

• Meter electronics and current transformers in a single package

• Split-core system eliminates the need to remove conductors

• Automatic compensation for CT orientation• Continuous TRMS Readings

Veris Current Switch & Relay

• Independent switch & relay operation• Command & status in one device• Adjustable setpoint• Relay & switch status LEDs simplify setup

H735

®

Page 16: Weschler DC Ammeter Shunts - Synergy Systems, Inc · Weschler DC Ammeter Shunts Type HA — 1 Through 500 Amperes Lightweight Types Type Lab — 10 Through 1000 Amperes Type MLC —

104

TRAN

SDUCER

S/S

ENSO

RS

If you control or monitor electric powered loads, you need currentswitches. Monitor fans, pumps, lights, and heaters for proper operation.Current switches give positive feedback that the load is operating andare much easier to install than alternatives like pressure switches, optical sensors, or zero speed switches.

AS and ASX current switches combine a currentsensor, signal conditioner, and limit alarm in asingle package. AS1 series are well suited toautomation systems of all kinds with their universal solid-state outputs and a wide frequency response. AS3 series have a high current output that works well with relay logiccontrol schemes. ASX series combine the AS3design with a built in adjustable time delay. Allmodels feature high visibility LED indication andrugged construction. AC monitoring models areavailable in solid and split core cases.

AS1 Series AS3 Series ASX SeriesPower Required: None — Self Powered None — Self Powered None — Self PoweredSetpoint Range: 1–150A (fixed core) 1–6, 6–40, 40–175A (fixed core) 1.5-12, 12-55, 50-200 A

1.5–150A (split core) 1–6, 6–40, 40–200A (split core)Isolation Voltage: UL Listed to 1270 VAC UL Listed to 1270 VAC UL Listed (pending)

to 1270 VACFrequency Range: 6–100 Hz 6–100 Hz 50-100 HzOutputsSolid State N.O.: 0.2A @ 240 VAC/VDC 1A @ 240 VAC 1.0A @ 240 VACSolid State N.C.: 0.2A @ 135 VAC/VDC 1A @ 240 VAC 1.0A @ 240 VACSolid State -15 Option: N/A 15A @ 120 VAC, 10A @240 VAC N/AOff State Leakage: None NC only: 2.5 mA NC only: 2.5 mAResponse Time: 0.120 Second 0.120 Second 0.1 SecondHysteresis: 5% of Setpoint 5% of Setpoint 5% of SetpointSensing Aperture: 0.55", 14 mm Dia. (FF Case) 0.55", 14 mm Dia. (FF Case) 0.75”, 19 mm Dia. (FT Case)

0.75", 19 mm Dia. (FT Case) 0.85", 21.5 mm Sq. (SP Case) 0.85”, 21.5 mm Sq. (SP Case)0.85", 21.5 mm Sq. (SP Case)

Case: UL 94V-O Flammability Rated UL 94V-O Flammability Rated UL 94V-0 Flammability RatedEnvironmental: -58 to 149° F (-50 to 65° C) -58 to 149° F (-50 to 65° C) 5 to 158 ° F (-15 to 70 ° C)

0–95% RH, Non-condensing 0–95% RH, Non-condensingListings: UL and ULC 508 Listed, CE UL and ULC 508 Listed, CE UL and ULC 508, CE (pending)

SPECIFICATIONS

NK Technologies AC Current Switches

FT Case Style

FF Case Style

SP Case Style

A Basic ModelAS1 AC Sensing, Single RangeAS3, ASX AC Sensing, 3 Ranges

B OutputNOU AS1 Normally OpenNCU AS1 Normally ClosedNOAC AS3, ASX, Normally OpenNCAC AS3, ASX, Normally Closed

ORDERING INFORMATION

NEW

To Order—Insert Number Code for Each Letter to Select Catalog Number. Example: AS1 - NCU-FT

A – B – C – D

C Case and ConnectionFF Fixed Core, Front ConnectionFT Fixed Core, Top Connection (AS1, ASX only)SP Split Core

D OptionsGO Fixed GO/No-GO Setpoint (AS1 only)(blank) Adjustable SetpointNL No LED (AS1, AS3 only)15 15A @ 120 VAC Output (AS3 only)

Page 17: Weschler DC Ammeter Shunts - Synergy Systems, Inc · Weschler DC Ammeter Shunts Type HA — 1 Through 500 Amperes Lightweight Types Type Lab — 10 Through 1000 Amperes Type MLC —

105

T RAN

SDUC

ERS

/S E

NSO

RS

Noshok Pressure Transducers and Transmitters

615/625

Series 1800 Attachable Loop Indicator

FM

Page 18: Weschler DC Ammeter Shunts - Synergy Systems, Inc · Weschler DC Ammeter Shunts Type HA — 1 Through 500 Amperes Lightweight Types Type Lab — 10 Through 1000 Amperes Type MLC —

106

TRAN

SDUCER

S/S

ENSO

RS

Noshok Pressure Transducers and Transmitters

100

Page 19: Weschler DC Ammeter Shunts - Synergy Systems, Inc · Weschler DC Ammeter Shunts Type HA — 1 Through 500 Amperes Lightweight Types Type Lab — 10 Through 1000 Amperes Type MLC —

106

Noshok Pressure Transmitter

The NOSHOK Series 750 digital pressure transmitter combines the reliability and long life of diffused semiconductor and sputtered thin film strain gage sensors with digital electronics for outstanding performance and value. With up to 20:1 span turn down and -2.5 to 99% zero point adjustment there is maximum flexibility to meet the most unusual application requirements. Additional features including 32 point process linearization, adjustable display orientation and integral process temperature measurement give the Series 750 an advantage over many other pressure transmitters.

• Up to 20:1 Span Turn Down• Proven D iffused S emiconductor or Sputt ered T hin Film Stra in Gage T echnology• Built-in Process T emperature D isplay• Built-in S electable Process D igital Filtering• Welded 316 S /S Pressure Chamber• 32 Point Process Linearization• Adjustable D isplay for Easy Viewing• 12 D ifferent Measurement Un its• CE Compliant

750

106a

Page 20: Weschler DC Ammeter Shunts - Synergy Systems, Inc · Weschler DC Ammeter Shunts Type HA — 1 Through 500 Amperes Lightweight Types Type Lab — 10 Through 1000 Amperes Type MLC —

107

TRAN

SDUC

ERS

/SE

NSO

RS

* 20°C, 60°C & 4°C reference options

ORDERING INFORMATION

Ashcroft Digital Pressure Gauges•• 41/2" Digit Display, 1/2" Character Height•• Maximum Pressure Indication•• Selectable Engineering Units•• Chemical Resistant Case•• Optional Weatherproof Boot

The D1005PS is a versatile andeconomical choice for general pres-sure applications. Stainless steel wettedparts are suitable for dry air and manyother media. Popular features such as backlight, peak hold and engineering units display are standard on the D1005PS.

To Order - Insert Range Code and Units to Complete Catalog Number.AS/D1005PS02L–30psi

AS/D1005PS02L

A Range (include units suffix)

SPECIFICATIONSCase Size: 21/2", Noryl®

Accuracy: 1/2% FS standard, 1/4% availableConnection: 1/4 NPT, bottomPower: 2 AAA batteries

4 level battery indicator in displayTemperature: -10°C to 60°C (14-140°F)Proof Pressure: 200%, up to 1000psi

150%, 3000 & 5000psi 120%, 9999psi

Keypad Functions:Auto/Off: Never, 5, 10, 20 minutesBacklight: 4 auto off optionsMax (Peak Hold): Displays peak valueZero/Clear: Zeroes display or clears max valueEngineering Units: psi, in.H2O, cmHg, mmHg, kPa, mPa,

Bar, kg/cm2, ft.H2O

Field Calibration: Zero and span

SPECIFICATIONS

•• 1/4% Full Scale Accuracy•• Extra Large 5 Digit Display•• 4-20mA & Switch Outputs in One

Unit (2274)•• NEMA4, IP65 Case•• Selectable Damping, Update Rate,

Engineering Units, Auto-Off•• Min/Max (Peak Hold) Display

Specify these multi-function digitalgauges when any combination of localindication, 4-20mA output and switching isrequired. Easy menu configuration speedsinstallation & setup. All points between zero and full scaleremain within stated accuracy even after rezeroing.

Digit Height: (3") 0.6”, (41/2") 0.88"Bargraph: 10 segment % of rangeTemperature: 10-60°C (14-140°F)Proof Pressure: 200%Loop Power: 12-36 VDCBattery: (3") Two AA, (41/2") Two CSwitch Rating: 30VDC/1A, 25VAC/0.5AApprovals: CE, FM, CSA

ORDERING INFORMATIONTo Order - Insert Code for Each Letter to Select Catalog Number.Example AS/302274SD02L –100psi–XU1BL

AS/

A Case 30 3" stainless steel45 41/2" thermoplastic

B Model2074 Battery powered2174 Loop powered, 4-20mA output2274 Line powered (12-36 VDC, 2VA)

C Wetted PartsSD 316 stainless steel (socket)

17-4 stainless steel (sensor)D Connection

02L 1/4 NPT04L 1/2 NPT (41/2" case only)

E Range (include units suffix)

F Options X followed by one or more2 digit codes:AY Black aluminum case for

41/2" sizeEC Electro polished case for 3" sizeU1 One SPDT switch (2274 only)U2 Two SPDT switch (2274 only)AO 4-20mA output for 2274EN Flying leads for 41/2" case

(terminal blocks std for 41/2" case, flying leads std for 3" case)

BL Display backlightBK Battery backup for 2174 & 2274S7 Weatherproof carry case (3" only)B1 Black rubber boot (3" only)B2 Orange rubber boot (3" only)PP Protective front cover (3" only)

psi ftH20 inH20 inHg/psi

30 70 -30/0 -30/3060 140 (vacuum) -30/60100 230 -30/100200 460 -30/150300 700 -30/300500 (compound)1000300050009999100001500019999

psi ftH20 inH20* mmH2O inHg mmHg compound

30 30 800 60 60 1500 15#/vac60 60 1000 100 100 2000 30#/vac100 160 160 160 3000 60#/vac160 200 200 200200 200 300 300300 300 400 400600 400 600 600800 600 800 8001000 1000 1000 10001500 16002000 20003000 30005000 60008000100001500020000

psi ftH20 inH20* mmH2O inHg mmHg compound

30 30 800 60 60 1500 15#/vac60 60 1000 100 100 2000 30#/vac100 160 160 160 3000 60#/vac160 200 200 200200 200 300 300300 300 400 400600 400 600 600800 600 800 8001000 1000 1000 10001500 16002000 20003000 30005000 60008000100001500020000

Also available:kPa, MPa, bar, kg/cm2 pressure ranges;kPa, mmHg, cmHg, bar, kg/cm2 vacuum ranges;kPa, bar, kg/cm2, ftH20 compound ranges.

Options:±0.25% of span accuracyProtective boot3, 9, 12 o'clock connections

D1005PS2174

– A

A B C D – E – F

Page 21: Weschler DC Ammeter Shunts - Synergy Systems, Inc · Weschler DC Ammeter Shunts Type HA — 1 Through 500 Amperes Lightweight Types Type Lab — 10 Through 1000 Amperes Type MLC —

108

TRAN

SDUCER

S/S

ENSO

RS

ORDERING INFORMATION

Ashcroft Pressure Gauges•• 4 1/2", Grade 2A (±0.5% FS)•• Long Life, Teflon Coated Movement•• Adjustable, Self-Locking Pointer•• Temperature Compensated•• Liquid-Filled Performance in a Dry

Gauge (option XLL)

The 1279 series is designed for longlife in harsh industrial applications.The phenolic case provides superiorchemical and heat resistance. Five bour-don tube systems handle a wide range of pressures and a variety of media. ThePlus!™ Performance option (XLL) reduces the effects of pulsationsand vibrations without the maintenance problems of liquid filling.

To Order - Insert Code for Each Letter to Select Catalog Number.Example: AS/1279BS02LXLLSG-0/3000psi

AASS//445511227799

AS/451279 41/2" Duragauge, grade 2AA Tube/Socket Material (max. psi)

A Phosphor bronze/brass (1000)B 4130 steel/1019 steel(5000)R 316 stainless/1019 steel (20000)S 316SS/ 316SS (20000)P K Monel/Monel 400 (30000)

B CaseS Solid frontSH Solid front, hermetic sealSL Solid front, liquid fill

C Connection02L 1/4 NPT, lower04L 1/2 NPT, lower02B 1/4 NPT, back04B 1/2 NPT, back

D Options X followed by 1 or more 2 digit codesLL Dynamic dampeningOS Overload stopTS Throttle screwSG Safety glassPD Plastic windowNN Paper tagNH Stainless steel tagGV Silicone filled

E Range (include units suffix)

Metric ranges also available.Other features and options available on request.

SPECIFICATIONS

•• 4 1/2", Grade 2A (±0.5% FS)•• 4-20 mA, 2-Wire Output•• Adjustable Zero & Span•• Hermetically Sealed Phenolic Case•• FM Approved to 10,000psi

Reliable Duragauge® construction pro-vides the analog pressure indication.An isolated optical sensor drives thetransmitter output.

Operating Temperature: -40°F to 160°FOverpressure: 130% of range w/o damage to tubePower Supply: 12-40VDCLoop Resistance: 500Ω max at 24V, 1kΩ max at 36VAdjustments: Transmitter span & zero adjustment on

dial, Gauge zero adjustment on pointerCase: Phenolic, hermetically sealedLens: Laminated safety glassElectrical: 30" leads, 1/2" liquid tight conduit fitting

ORDERING INFORMATIONTo Order - Insert Code for Each Letter to Select Catalog Number.Example AS/452279P04LXFMLL – 0/3000psi

AASS//445522227799

AS/ 2279 41/2" Duratran, grade 2AA Tube/Socket Material

S 316SS / 316SSP K Monel / Monel 400

B Case SH Solid front, hermetic seal

C Connection04L 1/2 NPT, bottom

D Options X followed by 1 or more 2 digit codes:LL Dynamic dampingFM FM approvalPD Plastic windowNN Paper tagNH Stainless steel tagGB Oxygen cleaned

E Range ( add psi suffix)

Metric, vacuum, compound, dual scale & receiver gauge dials available on request.Use 2288 series for lower ranges

A B C D – E

A B C D – E

psi Compound Vacuum0/15 0/800 30"Hg/15psi 30/0 inHg0/30 0/1000 30"Hg/30psi 34/0 ftH200/60 0/1500 30"Hg/60psi0/100 0/2000 30"Hg/100psi0/160 0/3000 30"Hg/150psi0/200 0/5000 30"Hg/300psi0/300 0/100000/400 0/200000/600 0/30000

Call for information on other Ashcroft dial gauges, including:•• Type 1009 21/2" & 31/2" Process Gauges, with ranges from vacuum to 15000 psi (Grade 1A, ±1% FS)•• Type 1083 3" Test Gauges, with ranges from vacuum to 1000 psi (Grade 2A, ±0.5% FS)

psi0/12 0/6000/15 0/8000/30 0/10000/60 0/15000/100 0/20000/160 0/30000/200 0/50000/300 0/100000/400 0/20000

1279 Duragauge®2279 Duratran®

Page 22: Weschler DC Ammeter Shunts - Synergy Systems, Inc · Weschler DC Ammeter Shunts Type HA — 1 Through 500 Amperes Lightweight Types Type Lab — 10 Through 1000 Amperes Type MLC —

108a

Ashcroft Test Gauges Ashcroft Pressure Switches•• Rugged & Portable •• 0.05% FS Total Error Band •• 0.66" Display Characters•• NEMA 4, IP65 Stainless Steel Case•• Selectable Damping, Update Rate,

Engineering Units, Languages•• Meets ASME B40.7

These Precision Digital Test Gauges are available with 0.05%, 0.1% or 0.25% total error band (TEB) accuracy. TEB accuracy includes the effects of linearity, hysteresis, repeatibility and temperature from 0 to 150°F. Ashcroft uses the conservative terminal point accuracy method for TEB. This allows rezeroing to eliminate sensor offset. All points between zero and full scale remain within stated accuracy.

SPECIFICATIONSDial: 3"Case: 300 series stainless steel, electroplated, weatherproof Proof pressure: 2X gauge pressure Display: 41/2" digit backlit LCD Bargraph: 10 segment % of range Temperature: -18 to 63°C (0-150°F) Battery: 3 AAA, >1000 hours EMI: CE EN50082-1 (1997)

Keypad Functions Engineering Units: psi, "Hg, "H2O, ftSW, Bar, mBar, kPa, mPa, mmHg, cmH2O,

mmH2O, kg/cm2

Update Rate: 10/sec, 5/sec, 2/sec, 1/sec Auto off: 2, 5, 15, 30 min, never Dampening: None, 2, 4, 6, 8 readings Min/Max: Stores min/max values when dispalyed Zero/Clear: Zeroes display or clears min/max values Backlight: on/off, 10 sec., 30 sec., 1 min., 5 min.Language: English, Spanish, French, Italian, German, Portuguese, Dutch Contrast: Seven levels Calibration: 10 points, password protected Configuration: Scroll thru menu & option choices

SPECIFICATIONS

•• Long Life Sensor & Relay (>10 million operations)

•• Watertight Metal Enclosure•• Deadband Adjustable to 0.5%•• Bright Local Display (optional)

This electronic pressure switch will outlast mechanical switches in high cycle applications. The pressure sensor is a stable thin film transducer with proven reliability and long life. The adjustable, narrow deadband solves many pipeline and elevated tank applications that cannot be satisfied with mechanical products. An optional LED display provides local pressure indication and simplifies switchpoint setup.

Enclose: Epoxy coated aluminum

NEMA 3, 4, 4X, 13 & IP66

Optional NEMA 7, 9 & Div I or II hazardous locations

Wetted Parts: 14-4 PH stainless steel diaphragm

AISI 316 stainless steel fitting

Display: 31/2 digit LED indicates process pressure ±1%

Status Lights: Process pressure, set pressure, reset pressure, relay output

Output: SPDT Relay rated 10A @250VAC/30VDC

Life: >10 million operations at rated load

Electrical: 3/4 NPT connection

ORDERING INFORMATION

A Function

NPA Single setpoint, adjustable

deadband

NPI Single setpoint, adjustable

deadband, process and

setpoint display

B Enclosure

N4 Watertight NEMA 3,4, 4X,

13 & IP66

N7 Explosion proof NEMA 3, 4, 4X,

13, 7, 9 & IP66 (NPA only)

C Output

D SPDT Relay

D Power Equipment

L 110VAC, 50/60Hz

C 24VDC

V 250VAC, 50/60Hz

E Pressure Port

S01 1/8 NPT Male

S02 1/4 NPT Male

S03 1/8 NPT Female

S04 1/4 NPT Female

S05 7/16 –20 SAE – 1

/4 SAE

S06 1/2 NPT Male & 1

/4 NPT Female

S07 1/4 AMINCO – Female

F Option

XEA External Setpoint Adjustment

— None

G Range

Setpoint psi psipsi Limits Proof Burst

60 3-60 120 480

100 5-100 200 800

200 10-200 400 1600

300 15-300 600 2400

500 25-500 1000 4000

750 35-750 1500 6000

1000 50-1000 2000 8000

2000 100-2000 4000 16000

3000 150-3000 4500 20000

5000 250-5000 7500 22500

7500 375-7500 9000 25000

10000 500-10000 12000 30000

15000 750-15000 18000 45000

20000 1000-20000 24000 60000

To Order – Insert Number Code for Each Letter to Select Catalog Number. Example: AS/NPAN7DCS02-100psi

AS/

ORDERING INFORMATIONTo Order - Insert Code for Each Letter to Select Catalog Number. Example AS/302089SD0L–100psi–XDB1

AS/30

A Model2089 0.05% FS accuracy 2086 0.10% FS accuracy 2084 0.25% FS accuracy

B Wetted PartsSD 316 stainless steel

C Connection02L 1/4 NPT, lower

D Range (include units suffix)

E OptionsXD 3 o’clock connection XE 9 o’clock connection B1 Black rubber boot B2 Orange rubber boot NH Metal Tag NN Paper Tag CD1 Certificate of Conformance C4 Certified Calibration data

(standard w. 2089)

2089 NPI

A B C D –– E

A B C D E F – G

Temperature options 4°C, 20°C, 60°F. Metric units available on request.(1) 2086 and 8084 only.(2) Accuracy meets ASME B40.7 resolution

requirements through 199.9 psi (200 psi) and 1999.9 psi (2000 psi).

psi Compound 10 600 15#/vac 15 800 30#/vac 30 1000 60 1500 100 2000(2)

160 2500(1)

200 (2) 3000300 5000 500 7000

psi (absolute)

1525(1)

50

Page 23: Weschler DC Ammeter Shunts - Synergy Systems, Inc · Weschler DC Ammeter Shunts Type HA — 1 Through 500 Amperes Lightweight Types Type Lab — 10 Through 1000 Amperes Type MLC —

109

TRAN

SDUC

ERS

/SE

NSO

RS

Kobold Temperature Transmitters

To Order - Insert Code for Each Letter to Select Catalog Number.Example KO/TMA-S2514A-025-05

KO/TMA -

A Fitting StyleS2514F 1/4" NPT, Fixed immersion depthS2512F 1/2" NPT, Fixed immersion depthS2514A 1/4" NPT, Adjustable depthS2512A 1/2" NPT, Adjustable depth

B Available Immersion Depth025 2.5" 040 4"060 6" 090 9"120 12"

C Available Measuring Range05 0 to 50°C (32/122 °F) 10 0 to 100°C (32/212°F) 15 0 to 150°C (32/302°F) 20 0 to 200°C (32/392°F) 40 0 to 400°C (32/752°F) 60 0 to 600°C (32/1112°F) 55 -50 to 50°C (-58/122°F) 51 -50 to 150°C (-58/302°F) 24 -200 to 400°C (-328/752°F) 26 -200 to 600°C (-328/1112°F) E Custom (specify)

The AUF display can be added to any 4-20 mA output that uses theHirshmann connector. Installed between the transmitter and the cable, theAUF is fully scalable through two control buttons. Power is provided by the 4-20 mA loop, so no additional power supply is required.

• 4-20mA Output• Hermetically Sealed Electronics • Easily Re-Programmable via PC • Low Cost and Easy Installation

The TST transmitter fits in a low profile housing which isonly 2" long. PC calibration software allows temperaturerange, offset, burnout options and other features to befield selected without recalibration.

Maximum Pressure: Threaded Version: 1500 PSIGTri-clamp Version: 500 PSIG

Probe Material: 316 Stainless Steel Power Required: 9-30 VDC loop powered RTD Type: Pt100, class BOutput Accuracy: ±0.1% of Span Ambient Temperature: -40°F to 158°F

To Order - Insert Code for Each Letter to Select Catalog Number.Example KO/TST-A4-040-PV-06-C

KO/TST -

A Fitting StyleA2 1/4" NPT, Adjustable immersion depthA4 1/2" NPT, Adjustable immersion depthF2 1/4" NPT, fixed immersion depthF4 1/2" NPT, fixed immersion depthT15 1 1/2" Tri-clampT2 2" Tri-clampT25 2 1/2" Tri-clampT3 3" Tri-clamp

B Available Immersion Depth025 2.5" 040 4"060 6" 090 9"120 12" 180 18"240 24" EP Custom (specify)C Cable (6' standard length)PV PVC jacket (220°C process max)TF Teflon jacketTA 316 SS armoredTB 316 SS braided0 None (use for option H)(BELOW)

D Available Measuring Range02 0 to 120°F 04 0 to 200°F06 0 to 300°F 08 0 to 400°F10 0 to 500°F 12 0 to 750°F14 0 to 950°F 16 0 to 1100°F18 -58 to 120°F E Custom scaling (specify)E OptionsC 1/2" NPT conduit hubH DIN43650 Hirshmann Plug in place of cableEC Extended cable length, specify length

KO/TST-PKIT Field calibration kit includes 9pin serial cable, 110VAC power pack & Windows software

SPECIFICATIONS

ORDERING INFORMATION ORDERING INFORMATION

SPECIFICATIONS

ORDERING INFORMATION

Ambient Temperature: -40°C to +70°CMax. Pressure: 1450 PSIG Probe: 316 SS, 1/4" diaPower Required: 12-36 VDC RTD Type: Pt100, class BOutput Accuracy: ±0.1% of Span Connector: Hirshmann plugProtection: NEMA 4X, IP65

SPECIFICATIONS

• 4-20mA Output, Loop Powered • Rugged 316 SS Construction • -200 to 600°C Range • Adjustable Zero & Span

The TMA series is factory calibrated. Zero and span potentiometers are accessible at the connector for recalibration.

Display: 4-digit red LED 5/16" tall Range: -1999 to 9999 Loop Voltage Load: 5 volts

Sampling Rate: 0.33-20s, adjustable Switch: Open Collector, 60mA max.,PNPProtection: NEMA 4

KO/AUF1000 Local Digital Display KO/AUF1001 Local Display w/Alarm

TMAwith optionalAUF display

TST

A B C D – E––– A B C––

Page 24: Weschler DC Ammeter Shunts - Synergy Systems, Inc · Weschler DC Ammeter Shunts Type HA — 1 Through 500 Amperes Lightweight Types Type Lab — 10 Through 1000 Amperes Type MLC —

110

TRAN

SDUCER

S/S

ENSO

RS

RA/MID-10LT Univ. Output, 10:1 optics, 1m cable, 85°C max sensor ambientRA/MIC-10LT Univ. Output, 10:1 optics, 1m cable, 125°C max sensor ambientRA/MIH-10LT Univ. Output, 10:1 optics, 1m cable, 185°C max sensor ambient

MI Series Miniature Infrared Sensors

SPECIFICATIONS

• Adjustable Emissivity,Peak/Valley Hold &Averaging

• 1% Accuracy from –40 to600°C (-40 to 1112°F)

• 10:1 Optics• Sensing Head Accessible for

Cleaning• RS-232 Communications

(RS-485 optional)

Two-piece infrared temperature measurement system with aminiature sensing head and die-cast electronics housing.

OPTIONS/ACCESSORIES- 4 RS485 Multidrop Communication- CB3 3m (10') Cable- CB8 8m (26') Cable- CB15 15m (49') Cable- V Display window in electronic housingRA/XXXMIACFB Fixed Mounting BracketRA/XXXMIACAB Adjustable Mounting BracketRA/XXXMIACAJ Air Purge CollarRA/XXXMIACCJ Air Cooling and Purge System

(includes 2.8' insulated air hose)RA/XXXCIDCPS Power Supply, 24VDC

ORDERING INFORMATION

Resolution 0.3°C or 0.5°FTemperature Range -40°C to 600°C (-40°F to 1112°F)

-25°C to 600°C for J T/C OutputOutputs 4-20mA, 0-20mA, 0-5V (scaleable)

J or K thermocouple10 mV/°C head ambient signal

Output Impedance (T/C) 20ΩMinimum Load Impedance (mV) 100kΩMaximum Loop Impedance (mA output) 500Ω with 24VDC

power supplyPower 11-26VDC, 100mAEnvironmental Rating IP65 (NEMA-4)Ambient Temperature:

MID Sensing Head 0 to 85°C (32 to 185°F)MIC Sensing Head 0 to 125°C (32 to 257°F)MIH Sensing Head 0 to 180°C (32 to 356°F)With air cooling up to 200°CElectronics housing 0 to 65°C

Temperature Coefficient MID 0.15K/K or 0.15%/KMIC, MIH 0.05K/K or 0.05%/K

Size Sensor 0.55" dia x 1.1" longHousing 3.2" x 2.4" x 1.0"

Spectral Response: 8 to 14 µmSystem Accuracy: (18-28°C ambient)

LT ±1% or ±1°CThermocouple output ±1% or ±2.5°C

Repeatability ±0.5% or ±0.5°CSystem Response Time 150ms (95%)Emissivity Transmission 0.100 to 1.100 digitally adjustable

RA/CI-1A IR Temperature Sensor, J T/C, 0-155°CRA/CI-2A IR Temperature Sensor, K T/C, 0-155°CRA/CI-3A IR Temperature Sensor,

10mV/°C Linear Voltage, 0-155°CRA/CI-1B IR Temperature Sensor, J T/C, 100-500°CRA/CI-2B IR Temperature Sensor, K T/C, 100-500°CRA/CI-3B IR Temperature Sensor,

10 mV/°C Linear Voltage, 100-500°C

-10L 3m (10') Cable, 105°C-W Air/water cooled jacket with

lens purge & 1m (3.3') 260°C cableRA/CIADJB Adjustable mounting bracketRA/CIACFB Fixed mounting bracketRA/CIACRA Right angle mirrorRA/CIAP Air purge collarRA/CI1CON Thermocouple cable extension

connector kit for CI1 RA/CI2CON Thermocouple cable extension

connector kit for CI2RA/CIACCB10H 3 Meter (10', 260°C) extension cableRA/CIACCB5OH 15 Meter (50', 260°C) extension cable

Raytek Infrared Temperature Sensors

• Type J or K, or 0-5 V Output• IP 65 (NEMA-4) Stainless Steel Electronics Housing• 4:1 Optics at 90% Energy• Powered by 12-24VDC at 20mA

Replaces traditional probes with J-type or K-type thermocouple output.

Functions accurately when used in conjunction with the thermocouplebreak protection circuitry in most controllers, displays, and transmitters.

Spectral Response 7 to 18 µmAccuracy ±2% or ±3°CResolution 0.5°CResponse Time 350ms (95%)Emissivity fixed at 0.95D:S Ratio 4:1Cable 1m (3.3') standardOutput Impedance (J/K) 50ΩMinimum Load (mV) 50kΩPower 12–24VDC ±5%, 20mAAmbient Temperature:

Sensing head 0 to 70°CWith air cooling up to 90°CWith water cooling up to 260°CRelative Humidity 10 to 95%, non-condensing

Size 0.75" dia. x 3.4" long

SPECIFICATIONS

ORDERING INFORMATION

OPTIONS / ACCESSORIES

CI Series Compact Infared Sensor

Page 25: Weschler DC Ammeter Shunts - Synergy Systems, Inc · Weschler DC Ammeter Shunts Type HA — 1 Through 500 Amperes Lightweight Types Type Lab — 10 Through 1000 Amperes Type MLC —

Accuracy (mV): ± 1.5% of reading or ± 2ºCAccuracy (T/C): ± 1.5% of reading or ± 4ºCSpectral Response: 8 to 14 micronsResolution: 0.1°CEmissivity: 0.10 to 1.10 (adjustable)Transmissivity: 0.10 to 1.00 (adjustable)Signal Processing: Peak hold, valley hold, variable averagingOutput: 100Ω Zout (TC types)

50kΩ min load (Voltage type)Self-diagnostics: Alarm, out of range, unstable, faultPower Supply: 12–24 VDC ±20% @ 10mADigital Output: Two-way RS232 digital outputAlarm Output: Transistor, 24VDC ±20% <20mAAmbient Temperature: 0-70°C (32-160°F)Housing: IP 65 (NEMA-4) stainless steelSize: 0.75" dia x 3.7" long, 3/4-16 UNF threadCable: 1m (3.3 ft) standard, 3m available

RAYCMLTV CM sensor, 0-5V user-scalable output RAYCMLTJ CM sensor, Type J TC outputRAYCMLTK CM sensor,Type K TC output

Add suffix 3 for 3m (9.8') cable

111

TRAN

SDUC

ERS

/SE

NSO

RS

• Measuring ranges to 23 feet in liquids, 11.5 feet in solids

• Narrow 5.5° beam angle • PVDF wetted parts • Accuracy 0.25% of full scale • 2-wire and 4-wire versions

The NUS series Ultrasonic LevelTransmitter is ideal for continuous, non-contact level measurement in liquidsand coarse grained or pelletized solids. This sensor allows reliable measurement ofdirty, viscous, and coating medium. The NUSboasts an extremely narrow beam to minimizeproblems due to obstructions in tall tanks. In addition to the 4-20mA output, a front panel LED readout is available.

The NUS series offers many advanced features including 11point linearization, fixed echo suppression, automatic stirrerecho suppression and output dampening. These features allowthe NUS series to be used in applications which render mostother ultrasonics useless. Calibration and setup is a simple task performed using a push-button driven menu.

Maximum Pressure: 40 PSIG Process Temperature: -40°F to 176°F Accuracy: 0.25% of Max. Range Resolution: ±0.12" Beam Cone Angle: 5.5° Maximum Loop Load: 600ΩOptional Display: 4 digit LEDCase: Epoxy coated AluminumProtection: NEMA 4X, IP65Electrical Connection: 1/2" NPTMeasuring Range2" NPT Models: 1.3 to 23.0 ft in liquids,

1.3 to 15 ft in solids1 1/2" NPT Models: 0.8 to 13.1 ft in liquids,

0.8 to 6.6 ft in solids

KO/NUS-1053N 1 1/2" fitting, 12-36VDC, 2-wire TransmitterKO/NUS-1051N 1 1/2" fitting, 90-127VAC, 4-wire Transmitter KO/NUS-2053N 1 1/2" fitting, 12-36VDC, 2-wire with DisplayKO/NUS-2051N 1 1/2" fitting, 90-127VAC, 4-wire with DisplayKO/NUS-1083N 2" fitting, 12-36VDC, 2-wire TransmitterKO/NUS-1081N 2" fitting, 90-127VAC, 4-wire Transmitter KO/NUS-2083N 2" fitting, 12-36VDC, 2-wire with DisplayKO/NUS-2081N 2" fitting, 90

Kobold Ultrasonic LevelTransmitter

SPECIFICATIONS

ORDERING INFORMATION

2083

CM

Raytek Programmable IR Sensors

SPECIFICATIONS

ORDERING INFORMATION

• -20 to 500°C (-4 to 932°F) Range• 13:1 Optics at 90% Energy• 150ms (95%) Response Time• RS-232 Digital Communications • Adjustable Signal Processing• DataTemp® Multidrop Software Compatible• Sensor status indicator LED

Designed for easy integration, the CM sensor with J-type or K-type thermocouple output can easily replace traditional contact probes. A user scalable 0-5 volt output is available forapplications susceptible to noise. This rugged, single pieceNEMA4 sensor has silicon optics to provide excellent optical resolution.

Page 26: Weschler DC Ammeter Shunts - Synergy Systems, Inc · Weschler DC Ammeter Shunts Type HA — 1 Through 500 Amperes Lightweight Types Type Lab — 10 Through 1000 Amperes Type MLC —

• 0.4 to 400 GPH sizes• Compact Size, Low Cost • Resistant to Aggressive Media

The DPL Series is ideal for applications requiring accurate flow measurement of transparent liquid media. A paddle wheel turbine interrupts an internal infra-red beam to generate a frequency output proportional to flow. The sapphire axle and bearing system assures long service life.

Detector Power: 4.6-16 VDC, 15mA max.Output Sink: 18mA max.Pull-up: Internal 10kohmOutput Signal: Frequency

Emitter LED:Supply: 15-50mA,Forward Voltage: 1.2-1.5VDC

Wiring: 6 ft. PVC cableAccuracy: ±5% of full scale

±1.5% optionalLinearity: ±1.5% optionalWetted Parts

Body: Polypropylene, sapphire, polysulfoneSeals: Buna-N standard,

Viton, EPDM optionalFittings: 1/2" bsp standard,

hose-barb 1/2" PVC optionalMax. Pressure: 145 PSIGTemperature: -40°F to 160°FProtection: NEMA 4X

Range NomFreq. at Max DPModel GPH oz/sec max flow (Hz) (PSI)KO/DPL-1005 0.4 - 8.0 0.014 - 0.28 272 11KO/DPL-1018 0.8 - 28 0.028 - 1.0 471 11KO/DPL-1060 3.0 - 95 0.11 - 3.4 528 10KO/DPL-1120 6.0 - 190 0.21 - 6.8 300 15KO/DPL-1250 16 - 400 0.57 - 14 399 19

-V Viton seals-E EPDM seals-S Hose Barb fittings, 1/2" PVC-F2 1/2 frequency -F4 1/4 frequency -F8 1/8 frequency-C ±1.5% accuracy calibration

Kobold Low Flow Sensor

SPECIFICATIONS

ORDERING INFORMATION

ORDERING INFORMATION

OPTIONS

111111aa

Newport USB Sensors

• Connects Directly to Computer USB Port

• Free Software Converts PC into Humidity/Temperature Meter, Data Logger or Chart Recorder

• 316 Stainless Steel Housing & Removable Filter

• Optional Wall Mount Kit

• 1000 Updates per Second• USB2.0 Compatible• Free Software Converts PC into

Data Logger or Chart Recorder• 316 Stainless Steel Wetted Parts• Gage or Absolute Pressure

RH-USB

DPL

Relative Humidity Range: 2 to 98% RHAccuracy: ±3% RH (@ 15 to 90% RH)Repeatability: ±1% RH

Temperature Range: -17 to 49°C (1 to 120°F)Accuracy: ±1°C (±1.8°F)

USB Connector: Type A plug on 2m (6') shielded cord Software (included free): Requires Windows® 2000, XP, VISTA (32-

bit) or Windows 7 (64-bit)Housing Material: 316 stainless steelDimensions: 138 L x 16 mm Dia (5.5 x 0.625")

Accuracy: 0.08% BSL typical (linearity, hysteresis & repeatability) Long Term Stability: ±0.1% FS typical, 1-YearIsolation: 100MΩ @50Vdc (2 MΩ after EMI filter), case to terminalA to D Conversion: 24-bit, 1000 updates per secondUSB Connector: Type A plug on 2m (6') shielded cord Temperature: -29 to 85°C (-20 to 185°F) compensated rangeWetted Parts: 316L stainless steel, IP65 ratingSensor Type/Life: Micro-machined silicon /1 million pressure cycles (min)Shock: 50 g, 11 mS half sine, vertical and horizontal axisDimensions: 119 L x 22 mm Dia (4.1 x 0.88"), ¼-18 NPT fitting

RH-USB Humidity temperature sensor with USB connectorCAL-3-HU NIST traceable calibration certificate.HX70-MKIT Wall/duct mounting kit

SPECIFICATIONS

SPECIFICATIONS

RANGE GAGE ABSOLUTEpsi bar Model No. Model No.0 to 10.00 inH2O 0 to 25.00 mb PX409-10WGUSB —0 to 1.000 0 to 69.00 mb PX409-001GUSB —0 to 2.500 0 to 172.0 mb PX409-2.5GUSB —0 to 5.000 0 to 345.0 mb PX409-005GUSB —0 to 15.00 0 to 1.000 PX409-015GUSB PX409-015AUSB0 to 30.00 0 to 2.100 PX409-030GUSB PX409-030AUSB0 to 50.00 0 to 3.400 PX409-050GUSB PX409-050AUSB0 to 100.0 0 to 6.900 PX409-100GUSB PX409-100AUSB0 to 150.0 0 to 10.30 PX409-150GUSB PX409-150AUSB0 to 250.0 0 to 17.20 PX409-250GUSB PX409-250AUSB0 to 500.0 0 to 34.50 PX409-500GUSB PX409-500AUSB0 to 750.0 0 to 51.70 PX409-600GUSB PX409-600AUSB0 to 1000 0 to 69.00 PX409-1.0KGUSB PX409-1.0KAUSB0 to 1500 0 to 103.0 PX409-1.5KGUSB PX409-1.5KAUSB0 to 2500 0 to 172.0 PX409-2.5KGUSB PX409-2.5KAUSB0 to 3500 0 to 241.0 PX409-3.5KGUSB PX409-3.5KAUSB0 to 5000 0 to 345.0 PX409-5.0KGUSB PX409-5.0KAUSB

ORDERING INFORMATION

PX409

Humidity/Temperature

Pressure

Page 27: Weschler DC Ammeter Shunts - Synergy Systems, Inc · Weschler DC Ammeter Shunts Type HA — 1 Through 500 Amperes Lightweight Types Type Lab — 10 Through 1000 Amperes Type MLC —

112

TRAN

SDUCER

S/S

ENSO

RS

Pyromation Insulated Thermocouples

Thermocouples and Thermocouple Wire Reference Junction 0°C (32°F)T/C Temperature Limits of ErrorType Range Standard Special

J 0 to 293°C (32 to 559°F) ± 2.2°C (4°F) ± 1.1°C (2°F)293 to 750°C (559 to 1382°F) ± 0.75% ± 0.4%

K 0 to 293°C (32 to 559°F) ± 2.2°C (4°F) ± 1.1°C (2°F)293 to 1250°C (559 to 2282°F) ± 0.75% ± 0.4%

E 0 to 340°C (32 to 644°F) ± 1.7°C (3°F) ± 1°C (2°F)340 to 900°C (644 to 1652°F) ± 0.5% ± 0.4%

T 0 to 133°C (32 to 270°F) ± 1° C (2°F) ± 0.5°C (1°F)133 to 350°C (270 to 662°F) ± 0.75% ± 0.4%

N 0 to 293°C (32 to 559°F) ± 2.2°C (4°F) ± 1.1°C (2°F)0 to 1250°C (559 to 2282°F) ± 0.75% ± 0.4%

* For sheathed thermocouples without leadwire or plug, part number ends with

H Sheath Terminations10(1) Sheath stripped 1"10(2) Sheath stripped 2"10(3) Sheath stripped 3"

Example PM/J43GM-012-00-10(1)

SPECIFICATIONS

The thermocouple element is encased in a metal sheath that can beformed and bent.

Extension leadwire of the same thermocouple material connects to remotepanel meters or transmitters. Sheath fittings can be specified to mountthe probe in thermowells with NPT threads.

Standard or Miniature Thermocouple Plugs are available to simplify fieldinstallation. These can be ordered with or without extension leadwire.

Thermocouple Extension Wire Reference Junction 0°C (32°F)

Ext. Wire Temperature Limits of Error

Type Range Standard Special

KX 0 to 200°C (32 to 392°F) ± 2.2°C (4°F) ------

JX 0 to 200°C (32 to 392°F) ± 2.2°C (4°F) ± 1.1°C (2°F)

EX 0 to 200°C (32 to 392°F) ± 1.7°C (3°F) ------

TX 0 to 100°C (32 to 212°F) ± 1.0°C (2°F) ± 0.5°C (1°F)

NX 0 to 200°C (32 to 392°F) ± 2.2°C (4°F) ------

To Order: Insert Code for Each Letter to Select Catalog NumberOrder Example PM/J43GM-012-10B-15-F3-036-2

ABCDE-F-G-H-I-J-KA Thermocouple Type

PM/J Type JPM/K Type KPM/E Type EPM/T Type TPM/N Type N

B Sheath Diameters 1 1/16" (0.063)2 1/8" (0.125)3 3/16" (0.188)4 1/4" (0.250)6 3/8" (0.375)

C Sheath Material8 316 stainless steel (type J, K, E, T)3 Inconel 600 (type J, K, E, T)9 304 stainless steel (type J, K, N)

D Junction TypeG GroundedU Ungrounded

E Limits of Error- StandardM Special

F Sheath Lengthnnn Three digit sheath length in inches

G Re-Adjustable Compression Fitting00 None10B 1/4" NPT SS for 1/4", 3/8" sheath OD10C 1/2" NPT SS for 3/16", 1/4" 11B 1/4" NPT Brass for 1/8", 3/16", 1/4", 3/8"11C 1/2" NPT Brass for 1/4", 3/8"

H Leadwire Transition*15 Relief spring (400°F rating)13 Same size transition00 None

I Extension LeadwireF3 Fiberglass (stranded)F3B Fiberglass with stainless steel overbraid (stranded)T3 Teflon (stranded)T3B Teflon with stainless steel overbraid (stranded)00 None

J Leadwire Length nnn Lead length in inches using 3 digits

K Wire Terminations2 2" split leads3 2" split leads w/ spade lugs4 Standard male plug6 Miniature male plug4MC Standard male plug with mating connector6MC Miniature male plug with mating connector

Other types and configurations available on request

ORDERING INFORMATION

Page 28: Weschler DC Ammeter Shunts - Synergy Systems, Inc · Weschler DC Ammeter Shunts Type HA — 1 Through 500 Amperes Lightweight Types Type Lab — 10 Through 1000 Amperes Type MLC —

113

TRAN

SDUC

ERS

/SE

NSO

RS

• Low and High temperature ranges• 3 or 4 wire elements• Accuracy exceeds DIN class B requirements• Rugged 316 stainless sheath

These high accuracy platinum RTDs are built to DIN specifications, with α=0.00385 and accuracy of ±0.1% @ 0°C. Call for other resistance values or configurations

Pyromation Platinum RTD’s

To Order: Insert Code for Each Letter to Select Catalog NumberOrder Example PM/R1T185H483-12-00-15-T3-048-2PM/ABCDE-F-G-H-I

A Temperature RangeR1T185L Low-temp -200°C to 204°CR1T185H Hi-temp -200°C to 600°C

B Sheath Diameters 28 1/8” (0.125)38 3/16” (0.188)48 1/4” (0.250)68 3/8” (0.375)

C RTD Element3 3 wire4 4 wire

D Sheath Lengthnn Two digit sheath length in inches

E Re-Adjustable Compression Fitting00 none10B 1/4" NPT SS for 1/4", 3/8" sheath OD10C 1/2" NPT SS for 3/16", 1/4" 11B 1/4" NPT Brass for 1/8", 3/16", 1/4", 3/8"11C 1/2" NPT Brass for 1/4", 3/8"

F Leadwire Transition15 Relief spring (400°F rating)13 Same size transition

G Extension LeadwireT3 3 conductor teflon insulationT3A 3 conductor teflon insulation with stainless steel flex armorF3 3 conductor fiberglass insulationF3A 3 conductor fiberglass with flex stainless steel armor

H Leadwire Length nnn Lead length in inches using 3 digits

I Wire Terminations2 Leads split 2" with 1/4" strip3 Leads split 2" with spade lugs

Vaisala Transmitters

• Silicon-Based NDIR Sensor• NEMA 4X enclosure• Interchangeable Probes• Easy Installation

• LCD Display Option• Analog Retransmit• Two Alarm/Relay Outputs

Dimensions: 4.7 x 4.7 x 1.3" + 4" sensor or remote probe

Housing: ABS plasticOperating -40 to 60°C (HMT100), -20 to 60°C (GMT220)Temperature (transmitter without display):

Probe Cable: Cable lengths to 39ft (10m) available

SPECIFICATIONS

The GMT Series Transmitters measure CO2 in harsh and humidenvironments. A patented sensor provides outstanding time andtemperature stability. The case is sealed and corrosion resistant.Choose from 10 measurement ranges: 2%, 3%, 5%, 10%, 20% full scale versions in the GMT221.2000, 3000, 5000, 7000 or 10000 ppm versions in the GMT222.

CO2 Transmitters

• Fixed or remote probe• Optional LCD display• Full 0-100% RH measurement

• Durable HUMICAP sensor• Quick-change probe• NEMA 4X, IP65 case

The HMT100 Series Transmitters are designed for humidity & tem-perature monitoring in demanding environments. The patentedhumidity sensor is resistant to dust & most chemicals. Singlechannel models transmit humidity or dewpoint. Dual channel mod-els also transmit temperature. Measurement range is 0-100%RH, -40 to 80°C temperature, -20 to 80°C dew point temperature.Units with 4-20mA output(s) are loop powered. Voltage outputmodels require an external 9-24VAC or 10-36VDC power supply.

Humidity Transmitter

NEW

Page 29: Weschler DC Ammeter Shunts - Synergy Systems, Inc · Weschler DC Ammeter Shunts Type HA — 1 Through 500 Amperes Lightweight Types Type Lab — 10 Through 1000 Amperes Type MLC —

To Order—Insert Code for Each Letter to Select Catalog Number. Order Example: HMT333 E0B201BCDC1B01AABC

A Cable Length E0 2m (6.5ft)F0 5m (16.3ft)G0 10m (32.5ft)

B Transmitter TypeA RH+TB RH+T+Td+Tdf+a+Tw+x+ppm+pw+pws+h+dT

C Display0 No display1 Graphic LCD with keypad

D Power Supply, Alarm Output0 10-35 VDC, 24 VAC1 10-35 VDC, 24 VAC isolated3 100-240 VAC with 115V cord

E Analog Output Level1 4-20 mA2 0-20 mA3 0-1 V4 0-5 V5 0-10 V

F Analog Output Signal (3 digits: Ch1, Ch2, Ch3) B RH 0 to 100%RHC TD Td -20 to +100 °C (-4 to +212 °F)E Tdf -20 to +100 °C (-4 to +212 °F)F a 0 to 600 g/m3 (0 to +262 gr/ft3)G Tw 0 to +100 °C (32 to 212 °F)H x 0 to 500 g/kg d.a. (0 to 3500 gr/lb d.a.)J h -40 to 1500 kJ/ kg (-17.2 to 644.9 Btu/lb)K ppm 0 to 5000L pw 0 to 1000 hPa (0 to 14.5 psi)M pws 0 to 1000 hPa (0 to 14.5 psi)N dT -10 to 50 °C (14 to 122 °F)

G Analog Output Range for TemperatureC -40 to +80 °C (-40 to +176 °F)D -40 to +120°C (-40 to +248°F)

H Output Units1 Metric2 Non-metric

I Options (2 Digits: Slot 1, Slot 2)1 Relay Output 2 RS-4854 Ethernet (requires external power) 6 Datalogger0 None

J Cable FittingA Cable gland M20*1.5B 1/2 NPT conduit fitting

K Mounting0 Normal1 Wall plate4 DIN rail

L Humidity Sensor1 General purpose, Humicap1802 with sensor purge, Humicap180C

M Sensor ProtectionA PPS grid & stainless steel netting (14 microns)B PPS plastic gridC Sintered stainless filter

N Installation KitAB NoneBB Duct

O PC AccessoriesA NoneB Serial cableC Software & cable

114

TRAN

SDUCER

S/S

ENSO

RS

Vaisala Humidity & Temperature Transmitters

• Measure humidity, temperature, dew point, mixing ratio, absolutehumidity and wet bulb temperature

• Small sensor head for use in tight spaces

• Small sensor mass for fast response

• Graphical display shows trends & 1 year history

• Analog & alarm relay outputs • Corrosion resistant

NEMA 4 (IP65) housing• Single point field calibration

The HMT333 Transmitter is a full featured front end for industrial and commercial humidity measurements. The HMT333 sensor provides accurate reading with excellent long-term stability, over the entire temperature range. The sensor is immune to particle contamination and most chemicals. A chemical purge to clean the sensor (via heating) can be initiated manually or at set intervals.

Two analog outputs easily connect to meters, controllers, recorders and otherequipment. The RS-232 interface simplifies setup and calibration. RS-485 &Ethernet options permit networking the HMT333 with other devices. Windows software is available to download and display the measurement data.

Datalogger option records up to 4 years of data.

Parameters: Standard: Relative Humidity (RH)

Temperature (T)Optional: Dewpoint Temperature (Td)

Absolute Humidity g/m3 (a)Wet Bulb Temperature (Tw)Mixing Ratio g/Kg (x)Enthalpy (h)

Temperature Range: -40 to 80°C (176 °F)Accuracy at 20°C: ±0.2°CTemperature dependence: ±0.0025°C/°CTemperature sensor: Pt100 class BRH Accuracy:

0-90 %RH: ±2% RH90-100 %RH: ±1.7% RHResponse time: 8 sec. in still air

Accuracy of analog output: ±0.05% full scaleExternal loads:

Current outputs: <500Ω0-1V output: >2kΩ0-5V & 0-10V outputs: >10kΩ

Power consumption @24VDC: 110mA max, 220ma during purge Operating temperature: -40 to 60°C (-40 to 140°F)

with local display: 0 to 60°C (32 to 140°F)Keypad: Sealed pushbuttonsDisplay menus: English, Spanish, French, German,Alarm relays: 0.5A@250VAC, SPDTRS 485/422 interface: Full or half duplex, 9600 baudDimensions:

Housing: 7.2x4.7x3.0" (183x119x77mm) Probe: 3.5" x 0.5"dia (89x 12mm)

SPECIFICATIONS

Additional HMT330 models available for high temperature (180°C), highpressure, vacuum, high humidity and other applications. Also available:HMT360 Series Intrinsically Safe Transmitters.

ORDERING INFORMATION

A B C

L M N

D E F G H I J KHMT333

HMT333

O

Page 30: Weschler DC Ammeter Shunts - Synergy Systems, Inc · Weschler DC Ammeter Shunts Type HA — 1 Through 500 Amperes Lightweight Types Type Lab — 10 Through 1000 Amperes Type MLC —

115

TRAN

SDUC

ERS

/SE

NSO

RS

MIK- Example MIK-5NAU4NL343

AA BBooddyy MMaatteerriiaall5NA Ryton with Buna-N Seal, 316L Electrode5VA Ryton with FKM Seal, 316L Electrode6FC PVDF with FFKM Seal, Hastelloy C4 Electrode

BB RRaannggee Fitting Set Size (") GGPPMM NN PP MM AA

U1 0.013-0.261/4 1/2 -- 1/2

U2 0.04-0.8U4 0.13-2.6

3/8 3/4 3/8 1/2 U5 0.2-4.0U7 0.4-8.0

1/2 1 1/2 1U8 0.65-13UA 0.8-16

1 -- 1 1-1/2 UB 1.3-26UD 2.0-40

1-1/2 -- 1-1/2 2UE 4.0-80UG 6.5-130

2 -- 2 2-3/4UH 10-200

CC FFiittttiinngg SSeett**N NPT female PVCP PVC hose barbM PVC glue socketA BSPP male

DD OOuuttppuuttF300 Frequency 0-500HzF390 User Specified 50-1000Hz full scaleL343 4-20mA C34N 4-20mA & NPN switchC34P 4-20mA & PNP switch

* PVDF butt weld tube & polypro NPT female fittings also available for some ranges.

Liquid: Conductivity >30 µS/cmAccuracy: ±2.0% of full scaleRepeatability: ±1% of full scaleStraight Pipe: Requires 3X dia. upstream, 2X downstreamOperating Temp.: 32–176°F (140°F max. with PVC fittings)Pressure: 145 PSIG max @ 70°FPressure Drop: 3.6 PSI max @ 100% rated flowElectrical Protection: NEMA 4X/IP 65Power Supply: 24 VDC ±20% requiredConnector: Micro-DC male, 4-pin (5-pin on C34)Frequency Output PNP open collector, 200 mA max.Analog Output 4–20 mA, 3-wire, 500Ω max.Switch Output PNP or NPN open collector, 300 mA max.

Compact electronic units (C34 Output Type) have a digital display and program-mable switch setpoint, reset point, switch logic, 4–20 mA span/zero, dampen-ing & lockout code. Set via 2-button keypad. Models with Integral Totalizer &Batch Controller electronics are also available.

Kobold Magneto-Inductive Flowmeters

MIK-C34

SPECIFICATIONS

ORDERING INFORMATIONA B C D–––

Display Type: 3-digit red LEDDisplay Resolution: 0.5° from -10° to +100°,

1° below -10 and above 100° Accuracy: 14 to 185°F: ±0.9°F

14 to -58°F: ±3.6°F185 to 250°F: ±3.6°F

Pressure: 1150 PSIG max.Process Temp: 250°F max.Ambient Temp: 120°F max.Material: 316L Stainless Steel housing & probeRemote Probe Cable: Teflon, 8ft. std.Power: 24 VDC ±20% @ 20 mA

Output: 4-20 mA, 3-wire, 500Ω max. loadSample Rate: 0.5 Sec./sampleDampening: Averaging 2, 4,8, 16, 32, or 64 samplesElectrical Connection: 4-Pin Micro-DC male plug or PVC jacketed cableElectrical Protection: NEMA 4/IP 65

Kobold Digital Temperature Sensor

SPECIFICATIONS

• Measuring Range -58 to 250°F

• Semiconductor Sensor• Scalable 4-20mA Output• Easy-to-Read LED Display• All Stainless Steel

Construction TDA ORDERING INFORMATIONTo Order: Insert Code for Each Letter to Select Catalog Number

TDA -15 – A B C D–––

A Process ConnectionN4 1/2" NPT N5 3/4" NPTR4 1/2" BSP R5 3/4" BSPD6 Remote Probe (Smooth Shank)

B Measuring RangeF2 0 to 250°F F3 -58 to 250°F (only available with Remote Probe)H2 -20 to 120°CH3 -50 to 125°C (only available with Remote Probe)

C Probe Length 0 12mm / 1/2" (not Available with Remote Probe) 1 100mm / 4"2 185mm / 7.25" (not Available with Remote Probe)

D Electrical ConnectionL3M Micro-DC plug, 4-Pin maleL3P 3 Ft. PVC cableL3S Custom length PVC cable

• Flow Rates from 0.26 GPM to 200 GPM

• Use with Conductive Liquids,Acids & Caustic

• No Moving Parts• Digital Display Option • Frequency or mA Output

Programmable Features• Lockout Code• Transmitter Span

• Dampening

Example TDA-15-N4-F2-0-L3M

NEW

Page 31: Weschler DC Ammeter Shunts - Synergy Systems, Inc · Weschler DC Ammeter Shunts Type HA — 1 Through 500 Amperes Lightweight Types Type Lab — 10 Through 1000 Amperes Type MLC —

116

TRAN

SDUCER

S/S

ENSO

RS

• Temperature Independent Output • 8 Segment LED Flow Rate Bar• Optional Setpoint Relay • Wide Viscosity Range • No Moving Parts • Extremely Low Pressure Loss • NPT & Sanitary Fittings

The KAL-A uses the calorimetric principle to continuously monitor the flow of both viscous and non-viscous media. Flow rate is transmitted via a 4-20mA output, while an optional switch provides an alarm function. A single RTD element is used to both heat the probe tip and measure temperature. The internal microprocessor compensates for media temperature changes. An absence of protrusions preventscontaminants from building up on the probe tip.

Sensing Range Water: 0.05 - 2 m/s Oils (approx.): 0.1 - 4 m/s

Response Time: 5.6s typ. Maximum Pressure: 1450 PSIG

(Sanitary 600 PSIG)Ambient Temperature: 0°F to 176°F CIP Temperature: 280°F Housing: NEMA 4 Nylon,

Explosion Proof (Al) optional Output: 4-20mA, 3-wire into 500Ω max. Linearity: ±10% of full scale Zero Adjustment: 0-75% of range Span Adjustment: 25-100% of range Power: 24±2VDC, 300mA max Switch Option:Adjustment: by Potentiometer Output: PNP open collector, 24V, 400mA max.Status Indicator: Bi-colored LED

KO/KAL-7215 304 SS Sensor, 1/2" NPT fittingKO/KAL-7315 316-Ti SS Sensor, 1/2"" NPT fittingKO/KAL-7320 316-Ti SS Sensor, 3/4" NPT fittingKO/KAL-7340S 316-Ti SS Sensor, 1 1/2" Tri-Clamp fitting

-P PNP Switch-M12 6’ cable & Micro DC connector Also available with switch output in place of 4-20mA output.

• 1-7 through 100-600 GPM Rates • Bronze or Stainless Housing• 4-20mA Process Output• Rugged 316 Stainless Steel Bellows

The RCD series uses an orifice technique to generate a differential pressure which varies with flowrate but is unaffected by system pressure fluctuations. The single measuring bellows is coupled to a high accuracy hall effect detector.

Maximum Pressure: 580 PSIG Maximum Temperature: 176°F Seals: Buna-NDisplay: 3 digit LEDOutput: 4-20mA, 3 wireOutput Accuracy: ±3% of full scale Input Power: 24VDC ±20%, 80mA Optional Switch: PNP or NPN open collector,

80mA max.Electronics Housing: 304 SS, NEMA 4xElectrical Connection: Micro-DC male, 5 pin

KO/RCD- ABCD Example KO/RCD-1105GN4C34PA Material

11 Bronze12 Stainless Steel

B Flow Rate & Fitting Size05GN4 1-7.2 GPM, 1/2" NPT10GN4 2-11.2 GPM, 1/2" NPT15GN5 2-17.6 GPM, 3/4" NPT20GN5 2.5-22.5 GPM, 3/4" NPT25GN6 5-35 GPM, 1" NPT30GN6 8-44.5 GPM, 1" NPT35GN8 10-73 GPM, 1 1/2" NPT40GN8 20-114 GPM, 1 1/2" NPT45GN9 20-184 GPM, 2" NPT50GN9 25-240 GPM, 2" NPT55GNB 30-280 GPM, 3" NPT60GNB 50-410 GPM, 3" NPT65GNB 100-620 GPM, 3" NPT

C TypeC3 Compact Electronics

D Output4P 4-20mA and 1 PNP switch4N 4-20mA and 1 NPN switch0R 2 PNP switches0M 2 NPN switches

Options-C Calibrate for specific gravity

other than water (<0.95 or >1.05)-V Calibrate for viscous liquids ( viscosity >10cSt)

Gas flowmeters also available.

SPECIFICATIONS

ORDERING INFORMATION

ORDERING INFORMATION

OPTIONS

SPECIFICATIONS

Kobold Differential Pressure & Thermal Flow Sensors

Page 32: Weschler DC Ammeter Shunts - Synergy Systems, Inc · Weschler DC Ammeter Shunts Type HA — 1 Through 500 Amperes Lightweight Types Type Lab — 10 Through 1000 Amperes Type MLC —

117

TRAN

SDUC

ERS

/SE

NSO

RS

• Designed to NEMA 6 / IP67 • Background Suppression • Light-ON and Dark-ON

Operate (Switch Selectable)• Highly visible Power

and Output LEDs• Small Object Detection• Maximum Sensing

Distance: 4", 6" or 8"

• Designed to NEMA 6 / IP67

• Visible Narrow Beam for Small Object Detection

• Input 10-30 VDC, Dual Output (PNP & NPN)

• Separate Power and Signal LEDs• PICO Style Quick Disconnect

or 6" Pig Tail Available

OPERATION Polarized Retroreflective (Model 3BR)Retroreflective or Diffuse (Model 3AR)

DETECTION RANGE Up to 160 ft. (48.8m) - RetroreflectiveUp to 12" (30.5cm) - Diffuse

OUTPUT Bi-Polar PNP/NPNRESPONSE TIME/ <2mS / >500HzFREQUENCY VOLTAGE 10 to 30 VDCREQUIREMENTS

SPECIFICATIONS

ORDERING INFORMATION

• Small footprint, M18 Compatible Housing• Visible Narrow Beam for Small

Object Detection• Easy Setup• Separate

Power and Signal LED’s

• Retroreflective or Diffuse

OPERATION Polarized Retroreflective Retroreflective or Diffuse

DETECTION RANGE Up to 160 ft. (48.8m)- RetroreflectiveUp to 12" (30.5cm)- Diffuse

OUTPUT Bi-Polar PNP/NPNRESPONSE TIME/ <2mS / >500HzFREQUENCYVOLTAGE 10 to 30 VDCREQUIREMENTS

ORDERING INFORMATION

777700 33AARR 0044 NN 33 BB QQPPBASIC MODEL 3AR Retro-reflective/Diffuse3BR PolarizedOPERATION04 Switch selectable

(light on/dark on)POWERN 10 - 30 VDCBEAM TYPE3 LaserOUTPUTB Bi-Polar (NPN & PNP)FEATURESQP Quick Disconnect Standard (PICO M8 4 Pin)K SpecialPT Pig Tail 6" standard (Micro 4 Pin)

Westcon Photoelectric Sensors

OPERATION Convergent BeamDETECTION RANGE 4 in., 6 in., 8 in.

(10.16, 15.2, 20.3cm)OUTPUT Bi-Polar PNP/NPNRESPONSE TIME/ <2mS / >500HzFREQUENCYVOLTAGE 10-30 VDCREQUIREMENTS

SPECIFICATIONS SPECIFICATIONS

ORDERING INFORMATION

777700 66AADD 0044 NN 33 BB QQPPBASIC MODEL 6AD DiffuseOPERATION 04 Switch selectable

(light on/dark on)POWERN 10 - 30 VDCBEAM TYPE3 Laser (Convergent)OUTPUT B Bi-Polar (NPN & PNP)FEATURES QP Quick Disconnect Standard (PICO M8 4 Pin) K Special

Flow Range, Liquids: 1.5-8 GPM through 225-500 GPM waterAccuracy: ±3% of full scaleRepeatability: ±1% of full scaleStraight Pipe Required: Inlet: 10 X Diameter

Outlet: 5 X DiameterOperating Temperature: -10 to 176°FMaximum Pressure: 580 PSIG @ 70°FWetted Materials:

Bronze Versions: Bronze, 316-Ti stainless steel, buna-N, ceramicStainless Versions: 316-Ti stainless steel, viton, ceramic

Programmable Functions: Lockout code, switch logic, switch setpoint and hysteresis, dampening

Input Power: 24 VDC ±20%, 80 mA Max.Display: 3 digit LEDSwitch Type: PNP open collectorSwitch Rating: 300 mA Max. short circuit protectedAnalog Output: 4-20 mA, 3-wire, RL=500 Ohms Max.

SPECIFICATIONS

Kobold Target-Type Flow Sensor

DPT-C

W7703

W7706 W7708

Standard Ranges (specify bronze or stainless body):FFiittttiinngg GGPPMM wwaatteerr3/8" NPT 1.5-8

3-12.51/2" NPT 1.5-8

3-183/4" NPT 1.7-15

5-251" NPT 5-20

20-3511/2" NPT 15-45

25-602" NPT 25-120

40-2003" NPT 175-400

225-500

• 1.5-8 to 225-500 GPM Water, • Bronze and Stainless Bodies• Variety of Wetted Materials• Line Sizes 3/8" to 3" NPT• Compact LED display with switch

and 4-20 mA flow transmitter

777700 88AARR 0044 NN 33 BB QQPPBASIC MODEL8AR Retroreflective8BR Polarized RetroreflectiveOPERATION04 On/OffPOWER REQUIREMENTSN 10 - 30 VDCBEAM TYPE3 LaserOUTPUT B Bi-Polar (NPN & PNP)FEATURES QP Quick Disconnect Standard (PICO M8 4 Pin) K Special PT Pig Tail 6 in. Standard (micro 4 pin)

Page 33: Weschler DC Ammeter Shunts - Synergy Systems, Inc · Weschler DC Ammeter Shunts Type HA — 1 Through 500 Amperes Lightweight Types Type Lab — 10 Through 1000 Amperes Type MLC —

118

TRAN

SDUCER

S/S

ENSO

RS

ROS-W Remote Optical SensorMT-190W Magnetic SensorP5-11 Proximity SensorIRS-W Infrared SensorAccessoriesT-5 Reflective Tape (5' x 1⁄2")

ROS-WOptical (1 to 250,000 RPM). Remote Optical Sensor with visible Red LED light source and Green LED on-target indicator. Complete with mounting bracket and 8' cable. Operatesup to 3 feet and 45° from reflective target. Stainless Steel Sensor .625" dia. By 2.9".

P5-11Proximity (1 to 60,000 RPM). Probe style inductive sensor for useup to .2 inches from a .5" metallic target. Can work with onepulse per revolution from bolt head, keyway, etc. SensorDimensions: M14X1 thread, 1.26" long.

MT-190W Magnetic Sensor with Amplifier (1 to 100,000 RPM).Recommended for use with 60 tooth gear, .25" gap, .106" polepiece dia., Sensor Dimensions: 5/8 x 18 UNF thread, 2" long.

IRS-WInfrared (1 to 999,990 RPM). Infrared Sensor with 8' cable. Usewithout Reflective Tape at .5" sensing gap from target. Senseswhite to black contrasting marks or beam can be interrupted by solid objects. Dimensions: 0.625"DIA x 2.9"L.

ROS-W

P5-11

MT-190W

ORDERING INFORMATION

Monarch Speed Sensors

IRS-5W

Type A 750-9901000Type A140R 750-282799

Type J2 750-9906000Type J2R 750-9906002Type M2 750-9906001

Type K3 750-9903000Type K30 750-9905000

Type W 750-9905002

Type E 750-9905001

A J2/M2 K3 W/E

MODEL 750 DC GENERATORS

• Corrosion-Resistant• 15,000 Hour Running Time

• Watertight Housings (Optional)• Explosion-Proof—UL Listed

(Type E)

OUTPUTModel 750: 6 VDC per 1000 RPM (5000 RPM max)Model 758: 10 VAC per 1000

Frequency Responsive Speed RangesF86 Series: 500 RPM-20,000 RPMF44 Series: 500 RPM-40,000 RPMF25: 40,000 RPM-100,000 RPM

SPECIFICATIONS

ATC Westcon Tach Generators

AB JB2 KB3

Type AB 758-9901000Type ABF 758-9901001

Type JB2 758-9905000Type JBF2 758-0133477-902Type JB5 758-9905001Type JBF5 758-0134030-901

Type KB3 758-9907000Type KBF3 758-9911000Type KB6 758-9908000

Type KBF6 758-0136522-902Type KB30 758-0134277-901Type KBF30 758-0134277-903

Type W 758-9910002Type WF 758-0133484-902

Type E 758-9910001Type EF 758-0131483-902

Type XF86 758-9989002Type XPF86 758-0077533Type GF86 758-9912002Type GPF86 758-0300008

Type XF44 758-0088466Type GF44 758-0049982Type GP44 758-0084866

BEARINGLESS AC GENERATORS

MODEL 758 AC GENERATORS

Page 34: Weschler DC Ammeter Shunts - Synergy Systems, Inc · Weschler DC Ammeter Shunts Type HA — 1 Through 500 Amperes Lightweight Types Type Lab — 10 Through 1000 Amperes Type MLC —

118a

Newport Load Cells

ORDERING INFORMATION

SPECIFICATIONS ORDERING INFORMATION

SPECIFICATIONSCapacity (lb.) Model Number0-25 LCGD-25 0-50 LCGD-50 0-100 LCGD-100 0-250 LCGD-250 0-500 LCGD-500 0-1000 LCGD-1K 0-2000 LCGD-2K 0-5000 LCGD-5K 0-10,000 LCGD-10K 0-50,000 LCGD-50K

Miniature Compression Load Cell

Excitation: 10 VAC/ DC Output: 2 mV/ V nominal Accuracy Class: 0.25% Material: Stainless Steel Linearity: ±0.25% FSO Hysteresis: ±0.20% FSO Repeatability: ±0.10% FSO Safe Overload: 150% FSO

Output: 3 mV/ V ±0.0075 mV/ V Excitation: 10 VDC (15 VDC max) Accuracy: 0.03% FSO Calibrated Air: 0%, 50%, 100%, 50%, 0% Linearity: 0.03% FSO Hysteresis: 0.02% FSO Repeatability: 0.02% FSO Zero Balance: ±1% FSO Safe Overload: 150% FSO Material: Stainless Steel

Cantilever Beams

Accessories for LC501 SeriesCapacity Model Load Button Rod End Base Plate(lb.) Number Model Model Model±100 LC501-100 LBC-012 REC-012M BP-10±200 LC501-200 LBC-012 REC-012M BP-10±500 LC501-500 LBC-012 REC-012M BP-10±1000 LC501-1K LBC-012 REC-012M BP-15±2000 LC501-2K LBC-012 REC-012M BP-15±5000 LC501-5K LBC-012 REC-012M BP-15±10,000 LC501-10K LBC-034 REC-034M BP-20

Compression Capacity Cable Style Connector Style (lb.) Model No. Model No.0-50 LC401-50 LC411-50 0-100 LC401-100 LC411-100 0-250 LC401-250 LC411-250 0-500 LC401-500 LC411-500 0-1000 LC401-1K LC411-1K 0-3000 LC401-3K LC411-3K 0-5000 LC401-5K LC411-5K 0-10,000 LC401-10K LC411-10K 0-20,000 LC401-20K LC411-20K 0-50,000 LC401-50K LC411-50K

Low Profile Load Cells

Output (FSO): 3 mV/ V ±0.25%

Excitation: 10 VDC (15 VDC max)

Calibrated at: 0%, 50%, 100%, 50%, 0%

Zero Balance: ±1% FSO

Safe Overload: 150% FSO

Compression Tension/CompressionLinearity: ≥3000 lb: 0.10% FSO 0.10% FSO

<3000 lb: 0.13% FSO 0.10% FSOHysteresis: ≥3000 lb: 0.10% FSO 0.08% FSO

<3000 lb: 0.12% FSO 0.08% FSORepeatability: 0.05% FSO 0.03% FSO

Model LC501

Model LC411

• Tension/Compression• Load Button, Rod End and Base Plate Mounting Accessories

LCGD-50LCGD-500

Tension/Compression

Capacity Model No.±50 LCHD-50 ±100 LCHD-100 ±500 LCHD-500 ±1K LCHD-500 ±3K LCHD-3K ±5K LCHD-5K ±10K LCHD-10K ±20K LCHD-20K ±30K LCHD-30K ±50K LCHD-50K

ORDERING INFORMATION

SPECIFICATIONS