Wellhead Pump Skid - National Oilwell Varco€¦ · N E S S I E Wellhead Pump Skid Section 2 -...
Transcript of Wellhead Pump Skid - National Oilwell Varco€¦ · N E S S I E Wellhead Pump Skid Section 2 -...
N E S S I EWellhead Pump Skid
Sect
ion
2 -
CON
TROL
Well
head
Con
trol E
quip
men
t
Reel Assembly
Calibration cylinders
This unit is a dual output unit for use in ATEX Zone 1 hazardous environments and in compliance with NORSOK regulations.
The unit features control of the Hydraulic Master Valve (HMV) and Down Hole Safety Valve (DHSV) and Balance Line. Hydraulic power is provided by two air driven pneumatic pumps with stainless steel hand pumps as backup.
All the regulators and valves required tooperate this unit are mounted on theunit for manual operation.
The unit is not designedfor open seas handlingand should be transferredusing a suitable container.
Performance Data & Specifications
Hydraulic Pump – Air / Hydraulic Pump.• Max Pressure 11,000psi (758bar)• Flow rate 0.75lpm @ 10,000psi (690bar)• Hydraulic Tank Capacity (combined) 30 litres
HMV• Maximum Pressure (manual control) 5,000psi (345Bar)• Maximum Pressure (10K hand pump) 6,000psi (414Bar)
DHSV• Maximum Pressure 10,000psi (690Bar)
Balance Line• Maximum Pressure 10,000psi (690Bar)
Sound Level• Maximum Sound Level (outside of unit) 80dB(A)
Digital Pressure Recording• Digital Pressure Gauge with Data logging
functionality
Environmental Conditions
• Design Temperature range -20oC to +40oC, the hydraulic oil and grease grades must be chosen to suit the local environmental conditions.
Power / External Supply
• Air Supply• Minimum pressure 80psi (5.5Bar)• Maximum pressure 100psi (7Bar)• Volume requirements minimum 50cfm
Design Standards
The wellhead pump skid will be designed using the following standards:• Machinery Directive 2006/42/EC. CE Marked• ATEX 95 (94/9/EC), Group 2 Category
2 (Zone 1)• NORSOK D-002 System Requirements
Well Intervention Equipment• NORSOK Z-015 Temporary Equipment
Certification
• CE marked, ATEX Approved for use in a Category 2 (Zone 1) hazardous area
Dimensions & Weights
PART NUMBER L-6901027712(L) 90 cm, 35 in (W) 90 cm, 35 in (H) 75 cm, 30 in (Maximum Gross Weight) 500 kg, 1,102 lbs
Control panel
© 2014 National Oilwell Varco www.nov.com/Elmar