Welcome to the QIAGEN Seminar · Welcome to the QIAGEN Seminar Standardization from Sample...
Transcript of Welcome to the QIAGEN Seminar · Welcome to the QIAGEN Seminar Standardization from Sample...
![Page 1: Welcome to the QIAGEN Seminar · Welcome to the QIAGEN Seminar Standardization from Sample Collection to Nucleic Acid Isolation: A Prerequisite for Reliable Molecular Analysis Ralf](https://reader035.fdocuments.in/reader035/viewer/2022071102/5fdbec6801c61a78b718d5cb/html5/thumbnails/1.jpg)
Innovation Working for You
Welcome to the QIAGEN Seminar
Standardization from SampleCollection to Nucleic Acid Isolation: A Prerequisite for Reliable Molecular Analysis
Ralf Wyrich, PhDSenior Scientist R&DDiagnostic Sample Preparation & StabilizationQIAGEN GmbH
![Page 2: Welcome to the QIAGEN Seminar · Welcome to the QIAGEN Seminar Standardization from Sample Collection to Nucleic Acid Isolation: A Prerequisite for Reliable Molecular Analysis Ralf](https://reader035.fdocuments.in/reader035/viewer/2022071102/5fdbec6801c61a78b718d5cb/html5/thumbnails/2.jpg)
Innovation Working for You
The Molecular Diagnostic Process
Pre-Analytical Steps
DetectionDataAssayRNA/DNA
PurificationTransportCollection
Analytical Steps
Array
![Page 3: Welcome to the QIAGEN Seminar · Welcome to the QIAGEN Seminar Standardization from Sample Collection to Nucleic Acid Isolation: A Prerequisite for Reliable Molecular Analysis Ralf](https://reader035.fdocuments.in/reader035/viewer/2022071102/5fdbec6801c61a78b718d5cb/html5/thumbnails/3.jpg)
Innovation Working for You
What happens to RNA in Biological Samples ex vivo?
Induction
mR
NA
cop
y nu
mbe
r
In
Sample collection
in vivo transcript level at t0
Cell death / enzymatic degradation
Time
![Page 4: Welcome to the QIAGEN Seminar · Welcome to the QIAGEN Seminar Standardization from Sample Collection to Nucleic Acid Isolation: A Prerequisite for Reliable Molecular Analysis Ralf](https://reader035.fdocuments.in/reader035/viewer/2022071102/5fdbec6801c61a78b718d5cb/html5/thumbnails/4.jpg)
Innovation Working for You
Transcription Profile Changes in Unpreserved Whole Blood Stored at Room Temperature
t0 4hr 8hr 24hr 3 days 5 daysNot enough signal to calculate ²Ct reliably
Value displayed is a minimum
Value displayed is a maximum
EDTA Blood Tube / GITC based RNA Isolation
Norm.Copy No.Data provided courtesy of Source Precision Medicine, Boulder, CO
![Page 5: Welcome to the QIAGEN Seminar · Welcome to the QIAGEN Seminar Standardization from Sample Collection to Nucleic Acid Isolation: A Prerequisite for Reliable Molecular Analysis Ralf](https://reader035.fdocuments.in/reader035/viewer/2022071102/5fdbec6801c61a78b718d5cb/html5/thumbnails/5.jpg)
Innovation Working for You
Integrated Solutions for a Wide Range of Starting Materials
Blood - PAXgeneTM Blood RNA System- PAXgeneTM Blood DNA System
Tissue - RNeasy® Protect System for Tissue- RNAlaterTM TissueProtect Tubes
Bacteria - RNeasy® Protect Bacteria Kits
![Page 6: Welcome to the QIAGEN Seminar · Welcome to the QIAGEN Seminar Standardization from Sample Collection to Nucleic Acid Isolation: A Prerequisite for Reliable Molecular Analysis Ralf](https://reader035.fdocuments.in/reader035/viewer/2022071102/5fdbec6801c61a78b718d5cb/html5/thumbnails/6.jpg)
Innovation Working for You
PAXgeneTM Blood RNA System
For Research Use Only
![Page 7: Welcome to the QIAGEN Seminar · Welcome to the QIAGEN Seminar Standardization from Sample Collection to Nucleic Acid Isolation: A Prerequisite for Reliable Molecular Analysis Ralf](https://reader035.fdocuments.in/reader035/viewer/2022071102/5fdbec6801c61a78b718d5cb/html5/thumbnails/7.jpg)
Innovation Working for You
Source Precision ProfileTM for Inflammation Subset
EDTA/GITC
PAXgene System
Gene Expression Profile Preserved with PAXgene
![Page 8: Welcome to the QIAGEN Seminar · Welcome to the QIAGEN Seminar Standardization from Sample Collection to Nucleic Acid Isolation: A Prerequisite for Reliable Molecular Analysis Ralf](https://reader035.fdocuments.in/reader035/viewer/2022071102/5fdbec6801c61a78b718d5cb/html5/thumbnails/8.jpg)
Innovation Working for You
Detection of Circulating Tumor Cells in Whole Blood by RT PCR
Positive detections out of 12 independant experiments
Tyrosinase detections over time
0
2
4
6
8
10
12
14
day 0 day 3 day 6 day10
WB (1)
PAX (1)
Tyrosinase detections over time
0
2
4
6
8
10
12
14
day 0 day 3 day 6 day10
WB (10)
PAX (10)
Data provided courtesy of N. S. Prang, Micromet, Munich
![Page 9: Welcome to the QIAGEN Seminar · Welcome to the QIAGEN Seminar Standardization from Sample Collection to Nucleic Acid Isolation: A Prerequisite for Reliable Molecular Analysis Ralf](https://reader035.fdocuments.in/reader035/viewer/2022071102/5fdbec6801c61a78b718d5cb/html5/thumbnails/9.jpg)
Innovation Working for You
RNAlater™ TissueProtect Tubes
Standardization of tissue collection
Time-zero preservation of cellular RNA and DNA at point of collection
Room temperature stability of intracellular RNA and DNA for 7 days
Sample stabilization during transport and storage
System integrated RNA + DNA isolation
For Research Use Only
![Page 10: Welcome to the QIAGEN Seminar · Welcome to the QIAGEN Seminar Standardization from Sample Collection to Nucleic Acid Isolation: A Prerequisite for Reliable Molecular Analysis Ralf](https://reader035.fdocuments.in/reader035/viewer/2022071102/5fdbec6801c61a78b718d5cb/html5/thumbnails/10.jpg)
Innovation Working for You
Stability of RNA in Rat Kidney Samples
0 5 10 15 30 60 0 5 10 15 30 60
Unstabilized Stabilized in RNAlater
minutesM
GAPDH
Agarose gel and Northern Blotting analysis
![Page 11: Welcome to the QIAGEN Seminar · Welcome to the QIAGEN Seminar Standardization from Sample Collection to Nucleic Acid Isolation: A Prerequisite for Reliable Molecular Analysis Ralf](https://reader035.fdocuments.in/reader035/viewer/2022071102/5fdbec6801c61a78b718d5cb/html5/thumbnails/11.jpg)
Innovation Working for You
Convenient Sample Handling and Processing without Liquid Nitrogen
Sample processing at RTNo liquid nitrogen or dry iceStorage, transport at RT or 4°CArchiving at -20°C or -80°C
RNeasy Protect Stabilization
![Page 12: Welcome to the QIAGEN Seminar · Welcome to the QIAGEN Seminar Standardization from Sample Collection to Nucleic Acid Isolation: A Prerequisite for Reliable Molecular Analysis Ralf](https://reader035.fdocuments.in/reader035/viewer/2022071102/5fdbec6801c61a78b718d5cb/html5/thumbnails/12.jpg)
Innovation Working for You
Crucial Factors for Sample Collection, Transport and Storage
No RNA degradationNo down-regulation of genesNo gene inductionIntegrated standardized systems
Accurate gene expression results
![Page 13: Welcome to the QIAGEN Seminar · Welcome to the QIAGEN Seminar Standardization from Sample Collection to Nucleic Acid Isolation: A Prerequisite for Reliable Molecular Analysis Ralf](https://reader035.fdocuments.in/reader035/viewer/2022071102/5fdbec6801c61a78b718d5cb/html5/thumbnails/13.jpg)
Innovation Working for You
Crucial Factors for RNA Purification
Sample type and sizeThroughput: manual / automationRNA elution volumeRNA yieldRNA quality– Integrity– Purity
RNA assay performance
1175
_RT
![Page 14: Welcome to the QIAGEN Seminar · Welcome to the QIAGEN Seminar Standardization from Sample Collection to Nucleic Acid Isolation: A Prerequisite for Reliable Molecular Analysis Ralf](https://reader035.fdocuments.in/reader035/viewer/2022071102/5fdbec6801c61a78b718d5cb/html5/thumbnails/14.jpg)
Innovation Working for You
Small Samples: Special Solutions needed
Special Silica Membrane Spin Column– low 2 µl dead volume
Low elution volume: 10 µl
RNA isolation from small samples
– ≤ 10 µg up to 5 mg tissue
– 1 single cell up to 5 x 105 cells
RNeasy Micro Kit
LMD, FNA, Biopsies– Functional Genomics– Target Identification– Oncology Research– Molecular Diagnostics
![Page 15: Welcome to the QIAGEN Seminar · Welcome to the QIAGEN Seminar Standardization from Sample Collection to Nucleic Acid Isolation: A Prerequisite for Reliable Molecular Analysis Ralf](https://reader035.fdocuments.in/reader035/viewer/2022071102/5fdbec6801c61a78b718d5cb/html5/thumbnails/15.jpg)
Innovation Working for You
Integrity of RNA: Rabbit Liver Fine Needle Aspirate
18S
28S
Fluo
resc
ence
Time (seconds)
0
5
10
15
20
25
30
35
40
45
19 24 29 34 39 44 49 54 59 64 69
RNAlater TissueProtect TubesTotal RNA by RNeasy MicroAgilent 2100 BioAnalyser
Fragment Name Start_Time(secs) End_Time(secs) Area %_of_total_Area
1 18S 39,88 42,00 34,44 14,05
2 28S 45,23 49,92 79,82 32,56
RNA Area 245,13
RNA Concentration(ng/ul) 90,20
rRNA Ratio [28S / 18S] 2,32
![Page 16: Welcome to the QIAGEN Seminar · Welcome to the QIAGEN Seminar Standardization from Sample Collection to Nucleic Acid Isolation: A Prerequisite for Reliable Molecular Analysis Ralf](https://reader035.fdocuments.in/reader035/viewer/2022071102/5fdbec6801c61a78b718d5cb/html5/thumbnails/16.jpg)
Innovation Working for You
Linearity of RNA Yield: Low Cell Numbers
RNeasy Micro Kit: 1 – 4.100 HeLa Cells
RT-PCR on LightCycler Linear RNA yield
![Page 17: Welcome to the QIAGEN Seminar · Welcome to the QIAGEN Seminar Standardization from Sample Collection to Nucleic Acid Isolation: A Prerequisite for Reliable Molecular Analysis Ralf](https://reader035.fdocuments.in/reader035/viewer/2022071102/5fdbec6801c61a78b718d5cb/html5/thumbnails/17.jpg)
Innovation Working for You
Fatty Tissues: Special Solutions Needed
Fat compounds interfere with many RNA isolation methods- Risk of low yield- Risk of inhibitors in RNA
Lysis by Phenol/GITC based QIAzol Reagent
RNA Purification by Silica MembranTechnology– Eliminates risk of phenol carry over into
RNA eluates
RNeasy Lipid Tissue Kit
![Page 18: Welcome to the QIAGEN Seminar · Welcome to the QIAGEN Seminar Standardization from Sample Collection to Nucleic Acid Isolation: A Prerequisite for Reliable Molecular Analysis Ralf](https://reader035.fdocuments.in/reader035/viewer/2022071102/5fdbec6801c61a78b718d5cb/html5/thumbnails/18.jpg)
Innovation Working for You
Integrity and Purity of Rat Brain RNA
Formaldehyde agarose gel,equal volume per lane
UV spectrophotometry
M
LMWRNAs
— 28 S
— 18 S
Agilent 2100 BioAnalyser
RNeasy
Pheno
l
![Page 19: Welcome to the QIAGEN Seminar · Welcome to the QIAGEN Seminar Standardization from Sample Collection to Nucleic Acid Isolation: A Prerequisite for Reliable Molecular Analysis Ralf](https://reader035.fdocuments.in/reader035/viewer/2022071102/5fdbec6801c61a78b718d5cb/html5/thumbnails/19.jpg)
Innovation Working for You
The RNeasy Technology - Advantages
standardized, reliable fast, easy to handle and reproduciblelow and high-throughput, fully automatedfree of contaminants (reliable quantitation, no inhibition ofenzymes)high-quality RNA
Accurate real-time gene expression results
![Page 20: Welcome to the QIAGEN Seminar · Welcome to the QIAGEN Seminar Standardization from Sample Collection to Nucleic Acid Isolation: A Prerequisite for Reliable Molecular Analysis Ralf](https://reader035.fdocuments.in/reader035/viewer/2022071102/5fdbec6801c61a78b718d5cb/html5/thumbnails/20.jpg)
Innovation Working for You