CERTIFICATE OF APPROPRIATENESS APPLICATION FORM Planner: ________________________________________________ Application received: ___ / ___ / ___ Application complete: ___ / ___ / ___ Rev. 01.2016 PROPERTY Address Historic District / Landmark HCAD # Subdivision Lot Block DESIGNATION TYPE PROPOSED ACTION Landmark Contributing Alteration or Addition Relocation Protected Landmark Noncontributing Restoration Demolition Archaeological Site Vacant New Construction Excavation DOCUMENTS Application checklist for each proposed action and all applicable documentation listed within are attached OWNER APPLICANT (if other than owner) Name Name Company Company Mailing Address Mailing Address Phone Phone Email Email Signature Signature Date Date ACKNOWLEDGEMENT OF RESPONSIBILITY Requirements: A complete application includes all applicable information requested on checklists to provide a complete and accurate description of existing and proposed conditions. Preliminary review meeting or site visit with staff may be necessary to process the application. Owner contact information and signature is required. Late or incomplete applications will not be considered. Deed Restrictions: You have verified that the work does not violate applicable deed restrictions. Public Records: If attached materials are protected by copyright law, you grant the City of Houston, its officers, agencies, departments, and employees, non-exclusive rights to reproduce, distribute and publish copyrighted materials before the Houston Archaeological and Historical Commission, the Planning Commission, City Council, and other City of Houston commissions, agencies, and departments, on a City of Houston website, or other public forum for the purposes of application for a Certificate of Appropriateness or building permit, and other educational and not for profit purposes. You hereby represent that you possess the requisite permission or rights being conveyed here to the City. Compliance: If granted, you agree to comply with all conditions of the COA. Revisions to approved work require staff review and may require a new application and HAHC approval. Failure to comply with the COA may result in project delays, fines or other penalties. 836 Fugate St Houston, TX 77009 Historic District 0621180000001 East Norhill 1 205 Jeff Brumbaugh 836 Fugate St Houston, TX 77009 713-366-1906 Jeffrey H. Brumbaugh 8/30/2016 Adam Wells Ethos Design Group, LLC 1940 Fountainview Dr #404 281.914.1741 08.30.2016

Transcript of Welcome to the City of Houston eGovernment Center - … · 2020. 12. 10. · February 25 February 3...

  • CERTIFICATE OF APPROPRIATENESS APPLICATION FORM

    Planner: ________________________________________________ Application received: ___ / ___ / ___ Application complete: ___ / ___ / ___

    Rev. 01.2016

    PROPERTYAddress

    Historic District / Landmark HCAD #

    Subdivision Lot Block

    DESIGNATION TYPE PROPOSED ACTION Landmark Contributing Alteration or Addition Relocation Protected Landmark Noncontributing Restoration Demolition Archaeological Site Vacant New Construction Excavation

    DOCUMENTS Application checklist for each proposed action and all applicable documentation listed within are attached

    OWNER APPLICANT (if other than owner)Name Name

    Company Company

    Mailing Address Mailing Address

    Phone Phone

    Email Email

    Signature Signature

    Date Date

    ACKNOWLEDGEMENT OF RESPONSIBILITYRequirements: A complete application includes all applicable information requested on checklists to provide a complete and accurate description of existing and proposed conditions. Preliminary review meeting or site visit with staff may be necessary to process the application. Owner contact information and signature is required. Late or incomplete applications will not be considered. Deed Restrictions: You have verified that the work does not violate applicable deed restrictions. Public Records: If attached materials are protected by copyright law, you grant the City of Houston, its officers, agencies, departments, and employees, non-exclusive rights to reproduce, distribute and publish copyrighted materials before the Houston Archaeological and Historical Commission, the Planning Commission, City Council, and other City of Houston commissions, agencies, and departments, on a City of Houston website, or other public forum for the purposes of application for a Certificate of Appropriateness or building permit, and other educational and not for profit purposes. You hereby represent that you possess the requisite permission or rights being conveyed here to the City. Compliance: If granted, you agree to comply with all conditions of the COA. Revisions to approved work require staff review and may require a new application and HAHC approval. Failure to comply with the COA may result in project delays, fines or other penalties.

    836 Fugate St Houston, TX 77009

    Historic District 0621180000001

    East Norhill 1 205

    Jeff Brumbaugh

    836 Fugate StHouston, TX 77009

    713-366-1906

    Jeffrey H. Brumbaugh8/30/2016

    Adam Wells

    Ethos Design Group, LLC

    1940 Fountainview Dr

    #404

    281.914.1741

    08.30.2016

  • CERTIFICATE OF APPROPRIATENESS APPLICATION INSTRUCTIONS

    Rev. 01.2016

    Well in advance of the COA application deadline contact staff to discuss your project, application requirements, and, if necessary, to make an appointment to meet with staff for a project consultation. Visit the Historic Preservation Web Manual for historic district profiles, project guidance and forms. www.houstontx.gov/HistoricPreservationManual

    Historic Preservation Office 832.393.6556 [email protected]

    SUBMISSION INSTRUCTIONS To submit application to Planning Department:

    • email documents to [email protected] (attachments must be less than 10MB) • send a Dropbox shared folder invitation to [email protected], or • contact staff to set up an appointment to drop off a disc or flash drive.

    MEETING SCHEDULE • Applications are due 22 calendar days in advance of the HAHC meeting by 12 PM (noon) on the deadline

    date. Exception: revisions to items deferred or denied at the previous HAHC meeting are due 15 days in advance of the scheduled meeting.

    • Application deadlines are firm. All materials must be submitted by the deadline to be considered at the following HAHC meeting. Designs must be final at time of application; revisions will not be accepted after the deadline.

    • HAHC will not accept new material or redesigns presented at the HAHC meeting. Deferral until the following month’s meeting may be necessary in such cases to allow for adequate review by staff and commissioners.

    • HAHC monthly meetings are held at 3:00 PM at City Hall Annex, 900 Bagby Street, City Council Chambers, Public Level.

    2016 Meeting Dates

    (Thursdays unless noted otherwise) COA Application Deadlines Demolition / Relocation Posted Sign Deadlines

    January 28 January 6 January 18

    February 25 February 3 February 15

    March 24 March 2 March 14

    April 21 March 30 April 11

    May 19 April 27 May 9

    June 16 May 25 June 6

    July 28 July 6 July 18

    August 25 August 3 August 15

    September 22 August 31 September 12

    October 20 September 28 October 10

    November 17 October 26 November 7

    December 14 (Wednesday) November 22 December 4

  • CERTIFICATE OF APPROPRIATENESS APPLICATION INSTRUCTIONS

    Rev. 01.2016

    DEFINITIONS Addition: any expansion to an existing building, structure or object. Alteration: any change to the exterior of a building or structure, including adding, moving, removing or replacing an exterior feature. Demolition: an act or process that destroys in whole, or a majority of, any building, structure, object or site. Excavation: to expose, uncover, or remove by digging, cutting or hollowing out. Exterior Feature: an element of the architectural character and the general arrangement of the external portion of a building, structure or object, including building materials and parts of the exterior wall assembly such as walls studs, interior shiplap and the foundation Mandatory Repair: a repair of a building or structure that is necessary to comply with Article IX, Ch. 10, Houston Code of Ordinances, as evidenced by an order of the hearing official or the building and standards commission or by a citation. New Construction: the erection of a new building, structure, or object, on a lot, site, or other property. Relocation: any change in the location of a building, structure, or object. Restoration: accurately recovering the form and detail of a building, structure, object, or site and its setting as it appeared at a particular period of time by means of the removal of later work, or by the replacement of missing earlier work, or both.

  • x

    x

    x

    x

    x

  • UP UP

    Living

    Dining

    Kitchen

    Bdroom

    BathBedroom

    Bath Study

    Existing Sliding Metal Window6'0" x 3'0"

    Existing Glass Block WindowsExisting DH Wood Window2'0" x 5'0"

    Existing DH Wood Window 2'0" x 3'0"

    1

    2

    34

    5

    6

    7

    8 9

    10

    1112

    13

    36

    37

    40 40

    41

    41

    41

    42

    41

    41

    41 41

    41

    41 41

    41

    41

    Living

    Dining

    Kitchen

    Bath

    Bedroom

    Bedroom

    Bath Study

    www.edghouston.com

    Scale

    Project numberDateDrawn byChecked by

    Designer: Ethos Design Group, LLCAddress: 1940 Fountainview Dr #404

    Houston, TX 77057Phone: 281.914.1741Fax:e-mail:

    Engineer: Address:

    Phone:e-mail:

    Client: Jeff BrumbaughAddress: 836 Fugate St

    Houston, TX 77009Phone: 713.366.1906Fax:e-mail:

    Builder: Ethos Design Group, LLCAddress: 1940 Fountainview Dr #404

    Houston, TX 77057Phone: 281.914.1741Fax:e-mail:

    Copyright (C) 2016 Ethos Design Group, LLCThis plan set is an instrument of service and shall remain theproperty of the designer. Using these drawings on any otherproject or extension to this project is prohibited without thewritten consent of both the engineer of record and thedesigner. Ethos Design Group, LLC, acting as the designer,will neither be responsible nor liable for constructionmethods or materials, including safety programs regardingthis project unless specifically hired as the generalcontractor.

    GENERAL NOTES1. Plans drawn to IRC-2012 standards (at minimum).2. Contractor must verify all dimensions and fieldconditions.3. Should any discrepancy exist between plans and actualproject, both the engineer of record and the designer ofrecord must be notified.4. Architectual drawings will show floor elevations, openingheights, etc; Contractor must refer to both architectural andstructural drawings to ensure proper layout of project.4. Designed for 110 MPH winds (3 second gusts) asrequired by IRC-2012.5. Designed for City of Houston.

    Print 11x17 *Borderless* to scale drawings 1/8" = 1'-0"

    A-0.0

    Existing & Demo

    FU-836

    RenovationBrumbaugh

    07.20.2016awellsawells

    No. Description Date

    1/8" = 1'-0"11st Floor Existing

    1/8" = 1'-0"21st Floor Demo

  • www.edghouston.com

    Scale

    Project numberDateDrawn byChecked by

    Designer: Ethos Design Group, LLCAddress: 1940 Fountainview Dr #404

    Houston, TX 77057Phone: 281.914.1741Fax:e-mail:

    Engineer: Address:

    Phone:e-mail:

    Client: Jeff BrumbaughAddress: 836 Fugate St

    Houston, TX 77009Phone: 713.366.1906Fax:e-mail:

    Builder: Ethos Design Group, LLCAddress: 1940 Fountainview Dr #404

    Houston, TX 77057Phone: 281.914.1741Fax:e-mail:

    Copyright (C) 2016 Ethos Design Group, LLCThis plan set is an instrument of service and shall remain theproperty of the designer. Using these drawings on any otherproject or extension to this project is prohibited without thewritten consent of both the engineer of record and thedesigner. Ethos Design Group, LLC, acting as the designer,will neither be responsible nor liable for constructionmethods or materials, including safety programs regardingthis project unless specifically hired as the generalcontractor.

    GENERAL NOTES1. Plans drawn to IRC-2012 standards (at minimum).2. Contractor must verify all dimensions and fieldconditions.3. Should any discrepancy exist between plans and actualproject, both the engineer of record and the designer ofrecord must be notified.4. Architectual drawings will show floor elevations, openingheights, etc; Contractor must refer to both architectural andstructural drawings to ensure proper layout of project.4. Designed for 110 MPH winds (3 second gusts) asrequired by IRC-2012.5. Designed for City of Houston.

    Print 11x17 *Borderless* to scale drawings 1/8" = 1'-0"

    A-0.1

    Existing ExteriorElevations

    FU-836

    RenovationBrumbaugh

    07.20.2016awellsawells

    No. Description Date

    1/8" = 1'-0"1West-Existing

    1/8" = 1'-0"2East-Existing

    1/8" = 1'-0"3North-Existing

    1/8" = 1'-0"4South-Existing

  • www.edghouston.com

    Scale

    Project numberDateDrawn byChecked by

    Designer: Ethos Design Group, LLCAddress: 1940 Fountainview Dr #404

    Houston, TX 77057Phone: 281.914.1741Fax:e-mail:

    Engineer: Address:

    Phone:e-mail:

    Client: Jeff BrumbaughAddress: 836 Fugate St

    Houston, TX 77009Phone: 713.366.1906Fax:e-mail:

    Builder: Ethos Design Group, LLCAddress: 1940 Fountainview Dr #404

    Houston, TX 77057Phone: 281.914.1741Fax:e-mail:

    Copyright (C) 2016 Ethos Design Group, LLCThis plan set is an instrument of service and shall remain theproperty of the designer. Using these drawings on any otherproject or extension to this project is prohibited without thewritten consent of both the engineer of record and thedesigner. Ethos Design Group, LLC, acting as the designer,will neither be responsible nor liable for constructionmethods or materials, including safety programs regardingthis project unless specifically hired as the generalcontractor.

    GENERAL NOTES1. Plans drawn to IRC-2012 standards (at minimum).2. Contractor must verify all dimensions and fieldconditions.3. Should any discrepancy exist between plans and actualproject, both the engineer of record and the designer ofrecord must be notified.4. Architectual drawings will show floor elevations, openingheights, etc; Contractor must refer to both architectural andstructural drawings to ensure proper layout of project.4. Designed for 110 MPH winds (3 second gusts) asrequired by IRC-2012.5. Designed for City of Houston.

    Print 11x17 *Borderless* to scale drawings 1/8" = 1'-0"

    A-0.2

    Roof Plans

    FU-836

    RenovationBrumbaugh

    07.20.2016awellsawells

    No. Description Date

    1/8" = 1'-0"1Existing Roof Plan

  • www.edghouston.com

    Scale

    Project numberDateDrawn byChecked by

    Designer: Ethos Design Group, LLCAddress: 1940 Fountainview Dr #404

    Houston, TX 77057Phone: 281.914.1741Fax:e-mail:

    Engineer: Address:

    Phone:e-mail:

    Client: Jeff BrumbaughAddress: 836 Fugate St

    Houston, TX 77009Phone: 713.366.1906Fax:e-mail:

    Builder: Ethos Design Group, LLCAddress: 1940 Fountainview Dr #404

    Houston, TX 77057Phone: 281.914.1741Fax:e-mail:

    Copyright (C) 2016 Ethos Design Group, LLCThis plan set is an instrument of service and shall remain theproperty of the designer. Using these drawings on any otherproject or extension to this project is prohibited without thewritten consent of both the engineer of record and thedesigner. Ethos Design Group, LLC, acting as the designer,will neither be responsible nor liable for constructionmethods or materials, including safety programs regardingthis project unless specifically hired as the generalcontractor.

    GENERAL NOTES1. Plans drawn to IRC-2012 standards (at minimum).2. Contractor must verify all dimensions and fieldconditions.3. Should any discrepancy exist between plans and actualproject, both the engineer of record and the designer ofrecord must be notified.4. Architectual drawings will show floor elevations, openingheights, etc; Contractor must refer to both architectural andstructural drawings to ensure proper layout of project.4. Designed for 110 MPH winds (3 second gusts) asrequired by IRC-2012.5. Designed for City of Houston.

    Print 11x17 *Borderless* to scale drawings

    A-0.3

    Schedules

    FU-836

    RenovationBrumbaugh

    07.20.2016awellsawells

    No. Description Date

    Window Schedule

    TypeMark Type Family Width Height

    HeadHeight Phase Created Phase Demolished

    40 24" x 60" Double Hung with Trim 2' - 0" 5' - 0" 6' - 8" Existing New Construction40 24" x 60" Double Hung with Trim 2' - 0" 5' - 0" 6' - 8" Existing None40 24" x 60" Double Hung with Trim 2' - 0" 5' - 0" 6' - 8" New Construction None40 24" x 60" Double Hung with Trim 2' - 0" 5' - 0" 6' - 8" New Construction None40 24" x 60" Double Hung with Trim 2' - 0" 5' - 0" 6' - 8" New Construction None41 30" x 60" Double Hung with Trim 2' - 6" 5' - 0" 6' - 8" Existing None41 30" x 60" Double Hung with Trim 2' - 6" 5' - 0" 6' - 8" Existing None41 30" x 60" Double Hung with Trim 2' - 6" 5' - 0" 6' - 8" Existing None41 30" x 60" Double Hung with Trim 2' - 6" 5' - 0" 6' - 8" Existing None41 30" x 60" Double Hung with Trim 2' - 6" 5' - 0" 6' - 8" Existing None41 30" x 60" Double Hung with Trim 2' - 6" 5' - 0" 6' - 8" Existing None41 30" x 60" Double Hung with Trim 2' - 6" 5' - 0" 6' - 8" Existing None41 30" x 60" Double Hung with Trim 2' - 6" 5' - 0" 6' - 8" Existing None41 30" x 60" Double Hung with Trim 2' - 6" 5' - 0" 6' - 8" Existing None41 30" x 60" Double Hung with Trim 2' - 6" 5' - 0" 6' - 8" Existing None41 30" x 60" Double Hung with Trim 2' - 6" 5' - 0" 6' - 8" Existing None41 30" x 60" Double Hung with Trim 2' - 6" 5' - 0" 6' - 8" Existing None41 30" x 60" Double Hung with Trim 2' - 6" 5' - 0" 6' - 8" New Construction None41 30" x 60" Double Hung with Trim 2' - 6" 5' - 0" 3' - 0" New Construction None41 30" x 60" Double Hung with Trim 2' - 6" 5' - 0" 7' - 0" New Construction None41 30" x 60" Double Hung with Trim 2' - 6" 5' - 0" 7' - 0" New Construction None41 30" x 60" Double Hung with Trim 2' - 6" 5' - 0" 7' - 0" New Construction None41 30" x 60" Double Hung with Trim 2' - 6" 5' - 0" 7' - 0" New Construction None41 30" x 60" Double Hung with Trim 2' - 6" 5' - 0" 7' - 0" New Construction None41 30" x 60" Double Hung with Trim 2' - 6" 5' - 0" 7' - 0" New Construction None42 30" x 36" Double Hung with Trim 2' - 6" 3' - 0" 6' - 0" Existing New Construction44 48" x 48" Casement with Trim 4' - 0" 4' - 0" 6' - 8" New Construction None45 24" x 36" Double Hung with Trim 2' - 0" 3' - 0" 6' - 8" New Construction None45 24" x 36" Double Hung with Trim 2' - 0" 3' - 0" 6' - 8" New Construction None45 24" x 36" Double Hung with Trim 2' - 0" 3' - 0" 6' - 8" New Construction None

    Door Schedule

    TypeMark Family Type Phase Created

    PhaseDemolished Width Height

    13 Double-Flush 60" x 80" New Construction None 5' - 0" 6' - 8"25 Double-Flush 48" x 80" New Construction None 4' - 0" 6' - 8"31 Overhead-Sectional 8' x 7' Existing None 8' - 0" 7' - 0"31 Overhead-Sectional 8' x 7' Existing None 8' - 0" 7' - 0"46 Single-Panel 4 30" x 80" Existing New Construction 2' - 6" 6' - 8"46 Single-Panel 4 30" x 80" Existing New Construction 2' - 6" 6' - 8"46 Single-Panel 4 30" x 80" New Construction None 2' - 6" 6' - 8"47 Single-Panel 4 36" x 80" Existing None 3' - 0" 6' - 8"60 Single-Panel 4 24" x 80" Existing New Construction 2' - 0" 6' - 8"60 Single-Panel 4 24" x 80" Existing New Construction 2' - 0" 6' - 8"60 Single-Panel 4 24" x 80" New Construction None 2' - 0" 6' - 8"61 Single-Panel 4 32" x 80" Existing None 2' - 8" 6' - 8"61 Single-Panel 4 32" x 80" Existing New Construction 2' - 8" 6' - 8"61 Single-Panel 4 32" x 80" Existing New Construction 2' - 8" 6' - 8"61 Single-Panel 4 32" x 80" Existing New Construction 2' - 8" 6' - 8"61 Single-Panel 4 32" x 80" Existing None 2' - 8" 6' - 8"61 Single-Panel 4 32" x 80" Existing None 2' - 8" 6' - 8"61 Single-Panel 4 32" x 80" Existing None 2' - 8" 6' - 8"61 Single-Panel 4 32" x 80" New Construction None 2' - 8" 6' - 8"61 Single-Panel 4 32" x 80" New Construction None 2' - 8" 6' - 8"61 Single-Panel 4 32" x 80" New Construction None 2' - 8" 6' - 8"75 Single-Pocket 30" x 80" Pocket New Construction None 2' - 6" 6' - 8"75 Single-Pocket 30" x 80" Pocket New Construction None 2' - 6" 6' - 8"75 Single-Pocket 30" x 80" Pocket New Construction None 2' - 6" 6' - 8"76 Single-Pocket 24" x 80" Pocket New Construction None 2' - 0" 6' - 8"80 Bifold-4 Panel 60" x 84" Existing New Construction 5' - 0" 7' - 0"80 Bifold-4 Panel 60" x 84" New Construction None 5' - 0" 7' - 0"81 Bifold-4 Panel 72" x 84" Existing New Construction 6' - 0" 7' - 0"83 Double-Glass 2 36" x 80" New Construction None 3' - 0" 6' - 8"

  • UP

    UPUP

    Add Doors to Bottom Shelves

    Shift Chandelier

    Bathroom6'0" x 8'5"

    Guest Closet4'0" x 6'9"

    Master Bath17'9" x 7'9"

    Master Bedroom15'5" x 11'7"

    Bookshelves Boookshelves

    Bedroom10'10" x 12'3"

    Kitchen11'8" x 17'5"

    Study14'4" x 11'7"

    Ref

    Pantry

    DW

    Trash

    Wine

    Linen

    Master Closet13'0" x 6'4"

    Optional W&D stacked

    3' -

    6"7' - 4 1/2"

    28' -

    5 3

    /4"

    Existing DH Wood Windows2'6" x 5'0"

    Proposed DH Wood Windows2'0" x 3'0"

    Existing DH Wood Window2'6" x 5'0"

    Existing DH Wood Window2'0" x 5'0"

    Proposed Fixed Wood Window4'0" x 4'0"

    Proposed DH Wood Windows2'0" x 5'0"

    Proposed DH Wood Window2'6" x 5'0"

    Existing 2'8" x 6'8"RHIS Wood Door

    Existing @8" x 6'8"RHIS Wood Door

    Existing 3'0" x 6'8" RHIS Wood Door

    1

    3

    12

    13

    15

    18

    31

    34

    35

    36

    37

    41

    40

    41

    41

    41

    41

    41

    41 41

    41

    41 41

    41

    41

    44

    40

    41

    40

    40

    45

    45

    45

    41

    Bedroom12'6" x 11'7"

    Bedroom16'0" x 11'5"

    Bathroom12'6" x 7'4"

    Optional Location for W&D

    50% back of front wall from original house

    12' - 6 1/4" 7' - 4 1/2"

    19' - 10 3/4"

    35' -

    6"

    3' -

    6"32

    ' - 0

    "

    Proposed DH Wood Windows2'6" x 5'0"

    42

    43

    44

    45

    46

    52

    53

    54

    41

    41

    41

    41

    41

    41

    41

    www.edghouston.com

    Scale

    Project numberDateDrawn byChecked by

    Designer: Ethos Design Group, LLCAddress: 1940 Fountainview Dr #404

    Houston, TX 77057Phone: 281.914.1741Fax:e-mail:

    Engineer: Address:

    Phone:e-mail:

    Client: Jeff BrumbaughAddress: 836 Fugate St

    Houston, TX 77009Phone: 713.366.1906Fax:e-mail:

    Builder: Ethos Design Group, LLCAddress: 1940 Fountainview Dr #404

    Houston, TX 77057Phone: 281.914.1741Fax:e-mail:

    Copyright (C) 2016 Ethos Design Group, LLCThis plan set is an instrument of service and shall remain theproperty of the designer. Using these drawings on any otherproject or extension to this project is prohibited without thewritten consent of both the engineer of record and thedesigner. Ethos Design Group, LLC, acting as the designer,will neither be responsible nor liable for constructionmethods or materials, including safety programs regardingthis project unless specifically hired as the generalcontractor.

    GENERAL NOTES1. Plans drawn to IRC-2012 standards (at minimum).2. Contractor must verify all dimensions and fieldconditions.3. Should any discrepancy exist between plans and actualproject, both the engineer of record and the designer ofrecord must be notified.4. Architectual drawings will show floor elevations, openingheights, etc; Contractor must refer to both architectural andstructural drawings to ensure proper layout of project.4. Designed for 110 MPH winds (3 second gusts) asrequired by IRC-2012.5. Designed for City of Houston.

    Print 11x17 *Borderless* to scale drawings 1/8" = 1'-0"

    A-1.0

    New Plan

    FU-836

    RenovationBrumbaugh

    07.20.2016awellsawells

    No. Description Date

    1/8" = 1'-0"11st Floor New

    1/8" = 1'-0"22nd Floor New

  • www.edghouston.com

    Scale

    Project numberDateDrawn byChecked by

    Designer: Ethos Design Group, LLCAddress: 1940 Fountainview Dr #404

    Houston, TX 77057Phone: 281.914.1741Fax:e-mail:

    Engineer: Address:

    Phone:e-mail:

    Client: Jeff BrumbaughAddress: 836 Fugate St

    Houston, TX 77009Phone: 713.366.1906Fax:e-mail:

    Builder: Ethos Design Group, LLCAddress: 1940 Fountainview Dr #404

    Houston, TX 77057Phone: 281.914.1741Fax:e-mail:

    Copyright (C) 2016 Ethos Design Group, LLCThis plan set is an instrument of service and shall remain theproperty of the designer. Using these drawings on any otherproject or extension to this project is prohibited without thewritten consent of both the engineer of record and thedesigner. Ethos Design Group, LLC, acting as the designer,will neither be responsible nor liable for constructionmethods or materials, including safety programs regardingthis project unless specifically hired as the generalcontractor.

    GENERAL NOTES1. Plans drawn to IRC-2012 standards (at minimum).2. Contractor must verify all dimensions and fieldconditions.3. Should any discrepancy exist between plans and actualproject, both the engineer of record and the designer ofrecord must be notified.4. Architectual drawings will show floor elevations, openingheights, etc; Contractor must refer to both architectural andstructural drawings to ensure proper layout of project.4. Designed for 110 MPH winds (3 second gusts) asrequired by IRC-2012.5. Designed for City of Houston.

    Print 11x17 *Borderless* to scale drawings

    A-1.1

    Renderings

    FU-836

    RenovationBrumbaugh

    07.20.2016awellsawells

    No. Description Date

    1 Aerial NW

    2 Aerial SW

    3 Street View NW

    4 Street View SW

    5 Aerial Roof Tie-in

  • 1st Floor0' - 0"

    1st Floor Ceiling8' - 0"

    2nd Floor Ceiling17' - 0"

    Grade-2' - 0"

    Roof Peak23' - 7 3/4"

    2nd Floor9' - 0"

    Original Window Shifted North by 6"New Windows for kitchen to match existing2'0" x 3'0" DH Wood Windows

    40' - 7 1/4"

    20' - 6 3/4"

    Original House depth

    All Windows 2'6" x 5'0"Sill Height 24"DH Wood Windows

    New 4'0" x 4'0" Fixed WindowNew 2'0" x 5'0" DH Wood WindowsSill Height 24" New 2'6" x 5'0" DH Wood Window

    Sill Height 24"

    www.edghouston.com

    Scale

    Project numberDateDrawn byChecked by

    Designer: Ethos Design Group, LLCAddress: 1940 Fountainview Dr #404

    Houston, TX 77057Phone: 281.914.1741Fax:e-mail:

    Engineer: Address:

    Phone:e-mail:

    Client: Jeff BrumbaughAddress: 836 Fugate St

    Houston, TX 77009Phone: 713.366.1906Fax:e-mail:

    Builder: Ethos Design Group, LLCAddress: 1940 Fountainview Dr #404

    Houston, TX 77057Phone: 281.914.1741Fax:e-mail:

    Copyright (C) 2016 Ethos Design Group, LLCThis plan set is an instrument of service and shall remain theproperty of the designer. Using these drawings on any otherproject or extension to this project is prohibited without thewritten consent of both the engineer of record and thedesigner. Ethos Design Group, LLC, acting as the designer,will neither be responsible nor liable for constructionmethods or materials, including safety programs regardingthis project unless specifically hired as the generalcontractor.

    GENERAL NOTES1. Plans drawn to IRC-2012 standards (at minimum).2. Contractor must verify all dimensions and fieldconditions.3. Should any discrepancy exist between plans and actualproject, both the engineer of record and the designer ofrecord must be notified.4. Architectual drawings will show floor elevations, openingheights, etc; Contractor must refer to both architectural andstructural drawings to ensure proper layout of project.4. Designed for 110 MPH winds (3 second gusts) asrequired by IRC-2012.5. Designed for City of Houston.

    Print 11x17 *Borderless* to scale drawings 1/8" = 1'-0"

    A-2.0

    New ExteriorElevations

    FU-836

    RenovationBrumbaugh

    07.20.2016awellsawells

    No. Description Date

    1/8" = 1'-0"1East

    1/8" = 1'-0"2West

  • 1st Floor0' - 0"

    1st Floor Ceiling8' - 0"

    2nd Floor Ceiling17' - 0"

    Grade-2' - 0"

    Roof Peak23' - 7 3/4"

    2nd Floor9' - 0"Sill Height 24"

    2'6" x 5'0" DH Wood Windows

    2'6" x 5'0" DH Wood WindowSill Height 24"

    www.edghouston.com

    Scale

    Project numberDateDrawn byChecked by

    Designer: Ethos Design Group, LLCAddress: 1940 Fountainview Dr #404

    Houston, TX 77057Phone: 281.914.1741Fax:e-mail:

    Engineer: Address:

    Phone:e-mail:

    Client: Jeff BrumbaughAddress: 836 Fugate St

    Houston, TX 77009Phone: 713.366.1906Fax:e-mail:

    Builder: Ethos Design Group, LLCAddress: 1940 Fountainview Dr #404

    Houston, TX 77057Phone: 281.914.1741Fax:e-mail:

    Copyright (C) 2016 Ethos Design Group, LLCThis plan set is an instrument of service and shall remain theproperty of the designer. Using these drawings on any otherproject or extension to this project is prohibited without thewritten consent of both the engineer of record and thedesigner. Ethos Design Group, LLC, acting as the designer,will neither be responsible nor liable for constructionmethods or materials, including safety programs regardingthis project unless specifically hired as the generalcontractor.

    GENERAL NOTES1. Plans drawn to IRC-2012 standards (at minimum).2. Contractor must verify all dimensions and fieldconditions.3. Should any discrepancy exist between plans and actualproject, both the engineer of record and the designer ofrecord must be notified.4. Architectual drawings will show floor elevations, openingheights, etc; Contractor must refer to both architectural andstructural drawings to ensure proper layout of project.4. Designed for 110 MPH winds (3 second gusts) asrequired by IRC-2012.5. Designed for City of Houston.

    Print 11x17 *Borderless* to scale drawings 1/8" = 1'-0"

    A-2.1

    New ExteriorElevations

    FU-836

    RenovationBrumbaugh

    07.20.2016awellsawells

    No. Description Date

    1/8" = 1'-0"1North

    1/8" = 1'-0"2South

  • UP

    UP

    A-2.01

    A-2.1

    A-2.0

    A-2.1

    1

    2

    2

    5' -

    1 1/

    4"

    4' - 3 1/2"

    34' - 9 3/4"

    27' -

    6 1

    /4"

    9' - 5 1/4"

    7' - 10 3/4"

    12' -

    10"

    3' -

    6"

    7' - 4 1/2"

    Addition

    Existing Garage

    ExistingCovered Porch

    Existin

    g Foot

    print

    104.

    00'

    104.

    00' Julian

    50' ROW

    Fugate50 ROW

    59.20'

    59.20'

    www.edghouston.com

    Scale

    Project numberDateDrawn byChecked by

    Designer: Ethos Design Group, LLCAddress: 1940 Fountainview Dr #404

    Houston, TX 77057Phone: 281.914.1741Fax:e-mail:

    Engineer: Address:

    Phone:e-mail:

    Client: Jeff BrumbaughAddress: 836 Fugate St

    Houston, TX 77009Phone: 713.366.1906Fax:e-mail:

    Builder: Ethos Design Group, LLCAddress: 1940 Fountainview Dr #404

    Houston, TX 77057Phone: 281.914.1741Fax:e-mail:

    Copyright (C) 2016 Ethos Design Group, LLCThis plan set is an instrument of service and shall remain theproperty of the designer. Using these drawings on any otherproject or extension to this project is prohibited without thewritten consent of both the engineer of record and thedesigner. Ethos Design Group, LLC, acting as the designer,will neither be responsible nor liable for constructionmethods or materials, including safety programs regardingthis project unless specifically hired as the generalcontractor.

    GENERAL NOTES1. Plans drawn to IRC-2012 standards (at minimum).2. Contractor must verify all dimensions and fieldconditions.3. Should any discrepancy exist between plans and actualproject, both the engineer of record and the designer ofrecord must be notified.4. Architectual drawings will show floor elevations, openingheights, etc; Contractor must refer to both architectural andstructural drawings to ensure proper layout of project.4. Designed for 110 MPH winds (3 second gusts) asrequired by IRC-2012.5. Designed for City of Houston.

    Print 11x17 *Borderless* to scale drawings 1/16" = 1'-0"

    C-0.0

    Site Plans

    FU-836

    RenovationBrumbaugh

    07.20.2016awellsawells

    No. Description Date

    1 Revision 1 Date 1

    1/16" = 1'-0"1Site

  • www.edghouston.com

    Scale

    Project numberDateDrawn byChecked by

    Designer: Ethos Design Group, LLCAddress: 1940 Fountainview Dr #404

    Houston, TX 77057Phone: 281.914.1741Fax:e-mail:

    Engineer: Address:

    Phone:e-mail:

    Client: Jeff BrumbaughAddress: 836 Fugate St

    Houston, TX 77009Phone: 713.366.1906Fax:e-mail:

    Builder: Ethos Design Group, LLCAddress: 1940 Fountainview Dr #404

    Houston, TX 77057Phone: 281.914.1741Fax:e-mail:

    Copyright (C) 2016 Ethos Design Group, LLCThis plan set is an instrument of service and shall remain theproperty of the designer. Using these drawings on any otherproject or extension to this project is prohibited without thewritten consent of both the engineer of record and thedesigner. Ethos Design Group, LLC, acting as the designer,will neither be responsible nor liable for constructionmethods or materials, including safety programs regardingthis project unless specifically hired as the generalcontractor.

    GENERAL NOTES1. Plans drawn to IRC-2012 standards (at minimum).2. Contractor must verify all dimensions and fieldconditions.3. Should any discrepancy exist between plans and actualproject, both the engineer of record and the designer ofrecord must be notified.4. Architectual drawings will show floor elevations, openingheights, etc; Contractor must refer to both architectural andstructural drawings to ensure proper layout of project.4. Designed for 110 MPH winds (3 second gusts) asrequired by IRC-2012.5. Designed for City of Houston.

    Print 11x17 *Borderless* to scale drawings

    Cover

    Cover & Index

    FU-836

    RenovationBrumbaugh

    07.20.2016awellsawells

    Sheet Index

    A-0.0 Existing & DemoA-0.1 Existing Exterior ElevationsA-0.2 Roof PlansA-0.3 SchedulesA-1.0 New PlanA-1.1 RenderingsA-2.0 New Exterior ElevationsA-2.1 New Exterior ElevationsC-0.0 Site Plans

    B r u m b a u g h R e s i d e n c e

    836 Fugate StHouston, TX 77009

    PROJECT INFO:

    1 Schematic Design-Initial Draft

    No. Description Date

    1 Rendering

    Remodel Interior 1,053Addition of 2nd Story 609Total 1,662