Welcome to STRAP Software Presentation · 2020. 6. 28. · Design of composite structures Cold...

50
STRAP Software Presentation Welcome to

Transcript of Welcome to STRAP Software Presentation · 2020. 6. 28. · Design of composite structures Cold...

  • STRAP Software Presentation

    Welcome to

  • STRAP Software for

    ➢ RC structures design, detailing and scheduling.

    ➢ Design & Optimization of steel structures

    ➢ Design of composite structures➢ Cold formed steel design➢ Analysis of Bridges➢ Design of water retaining

    structures➢ Post tensioning for beams & slabs

  • STRAP For RC Designers

    Fully Automatic and Integrated

    system for RC Structure design,

    detailing and construction

    drawing production with BBS

    www.ramcadds.com

  • STRAP For RC Designers

    RC Frames + Shear walls + Lift

    cores + Flat slabs + Raft

    Modeling .. All in one system

  • STRAP For RC Designers

    Special Features for Shear Wall Modeling

    Any complicated shear

    wall/ lift core section can

    be defined in single step

    Automatic generation of rigid links

    for efficient load transfer

    Program automatically generates additional beams, where ever

    coupling beams are defined for proper moment transfer

  • STRAP For RC Designers

    ➢ Possibility to define opening in the shear wall

    ➢ Automatic creation of nodes when wall section changes

    ➢ Change the wall section by moving the node in the main geometry

    Special Features for Shear Wall Modeling

  • STRAP For RC Designers

    FE Modeling is very SimpleUser controlled

    mesh sizeAutomatic

    meshing

    Automatically

    aligns with

    existing nodes

    Automatically aligns with

    adjacent elements

  • STRAP For RC Designers

    Beam design and detailing

    Reinforcement for beams for

    the moment at the face of

    the column. Considerable

    savings on reinforcement.

    Program automatically

    detects continuous beams

    Cost effective designs

  • STRAP For RC Designers

    Automatic Calculation

    of effective length factors

    Automatic

    Detection of un supported

    lengths for column design.

    Automatic detection unsupported lengths

  • STRAP For RC Designers

    RC Column Design features

    ➢Design for any shaped cross sections

    ➢Automatic Optimization of reinforcement

    for a given cross section.

    ➢The column capacity calculation is exact.

    Program calculates neutral axis and stress

    & strain in each bar from neutral axis.

    ➢Reinforcement can be grouped for different

    levels and different columns.

    ➢Graphical Display of reinforcement and column

    capacity factor.

    User can specify the

    reinforcement in the

    column

  • STRAP For RC Designers

    Reinforcement can be changed after

    detailing. The program automatically

    checks for codal provisions.

    Automatic drawing

    of cross sections

    Graphical

    display of

    Envelope of

    Required Rft

    Beam Detailing

  • STRAP For RC Designers

    BBS and quantity estimation

    Total quantity

    All standard shape

    codes are available.

    In addition to that

    user can add their

    own shape codes.

    Automatic scheduling &

    quantity calculation

  • STRAP For RC Designers

    Column detailing & BBS

    Detail and draw all

    columns

    in tabular formatAutomatically calculates

    bar schedule for the total

    drawing

    Automatically draws

    elevation & Cross

    Section for selected

    column

  • STRAP For RC Designers

    SLAB detailing &

    BBS

  • STRAP For Steel Designers

    Steel Design/Optimization

    If you are serious in designing Least Cost Steel

    Structures then STRAP is the best choice for you.

  • STRAP For Steel Designers

    ➢ The shapes can be arbitrary combinations of standard steel sections, plates and sections defined by dimensions.

    ➢ Above arbitrary shape can be designed in steel post processor

    User defined steel section shapes

  • STRAP For Steel Designers

    ➢ Slender sections can be designed as per Indian code

    ➢ Design of castellated and cellular beams

    ➢ Spilt beam with tapered section. Program automatically creates new sections at the new intermediate nodes for a tapered beam

    Design of slender sections

  • STRAP For Steel Designers

    Automatic Calculation

    of unsupported lengths

    Design of single/ star

    angles about principal

    axis.

    Automatic detection unsupported lengths

  • STRAP For Steel Designers

    COMPOSITE SECTIONS

    ➢Calculation of shear studs

    ➢Partial shear connection

    ➢Design for wet concrete condition

    ➢Calculation of short term and long

    term deflections

    ➢Option to account for negative

    moment reinforcementComposite column

    and beam design

    Analysis and design of composite columns and beams

  • For Transmission Tower Designers

    ➢IS 802 is available for tower design

    ➢Automatic generation of wind load on towers/ Open

    structures.

    ➢Different cost factors can be assigned to various section

    types or member groups.

    ➢Selection of sections can be subject to user constraints.

    Specify the deflection or drift, program automatically

    optimizes the whole structure

    - Engineer can get the least cost structure using STRAP!!!

    For Cost Optimization

    STRAP For Steel Designers

  • STRAP For Steel Designers

    Automatic GA drawing preparation and quantity

    calculations.

    Export through DXF

    to any cad programs.

  • STRAP For Steel Designers

    Automatic design of steel connections

    ➢ Beam to beam

    ➢ Column web to Beam

    ➢ Column Flange to Beam

    ➢ Column base plate design

    ➢ Design for AISC, BS & Euro Code

  • STRAP For Steel Designers

    ➢Design for AISI, BS and Euro codes

    ➢New section types can be added to the

    library by defining the basic dimensions only.

    ➢Calculation of torsional flexural buckling for

    LTB

    ➢Design for reduced section according to the

    web thickness/depth ratio

    ➢Hot rolled sections can be used in the same

    model.

    ➢To define new sections apart from standard,

    CROSEC module is necessary.

    For Cold Formed Steel DesignersStandard Sections + user can create customized sections

    We recommend

    STRAP + Cold formed+ CROSEC for cold formed steel

    designers

    Simple to most complicated sections can be

    analyzed and designed.

  • ➢Appendix A - "Calculation of minimum

    reinforcement, crack spacing and crack widths in

    relation to temperature and moisture effects“

    ➢Appendix B - "Calculation of crack widths in

    mature concrete“ - The program calculates the

    reinforcement required to satisfy moment/

    force requirements

    STRAP For Water retaining structures

  • ➢ Automatic calculation of nodal weights

    ➢ Simple to define rigid diaphragm actions

    ➢ Inbuilt response spectra for various damping ratios

    ➢ Possibility to use site spectra

    ➢ Automatic scaling of response spectrum results

    ➢ Option to define eccentricities at various levels

    ➢ Assign to the CQC the signs of the results calculated for the dominant mode shape

    STRAP Earthquake Analysis

  • ➢ The storey drift in any storey shall not exceed 0.004 times the storey height

    STRAP Earthquake AnalysisStorey drift calculations

  • STRAP 2012 – New features

    ➢ Program will list centre of mass and centre of rigidity for each floor.

    STRAP Earthquake AnalysisRigidity & mass centre

  • Storey Shear & Moments

    STRAP Earthquake Analysis

  • Stability coefficient (Theta)➢ P-Delta effects on story shears and moments are not

    required to be considered where the stability coefficient (Theta ) is equal to or less than 0.10"

    STRAP Earthquake Analysis

  • Weak Stories Calculation➢ A weak storey is one in which the storey lateral

    strength is less than 80% of that in the storey above

    STRAP Earthquake Analysis

  • Soft Storey Calculation➢ A soft storey is one in which the lateral stiffness is less than

    70% of that in the storey above or less than 80% of the average lateral stiffness of the three storeys above

    ➢ the columns and beams of the soft storey are to be designed for 2.5 times the storey shears and moments calculated under seismic loads

    STRAP Earthquake Analysis

  • Models from Users

  • Models from Users

  • Models from Users

  • Models from Users

  • Models from Users

  • Models from Users

  • Models from Users

  • Models from Users

  • Models from Users

  • Models from Users

  • Models from Users

  • Models from Users

  • Models from Users

  • Models from Users

  • Models from Users

  • STRAP 2012 – New features

    Models from Users

  • Models from Users

  • Models from Users

  • For more information contact us at [email protected]

    Ram Caddsys Pvt. Ltd.A8, Vaigai Apartments4, Giri Street, Westmambalam,Chennai, India. Zip: 600 033.Tel: 00-91-44-2474 7738 /Email: [email protected]: www.ramcadds.in

    mailto:[email protected]://www.ramcadds.in/