Week 1 Unit Conversions Mass and Volume Flow Ideal Gas Newtonian Fluids, Reynolds No . Week 2

35
Week 1 Unit Conversions Mass and Volume Flow Ideal Gas Newtonian Fluids, Reynolds No. Week 2 Pressure Loss in Pipe Flow Pressure Loss Examples Flow Measurement and Valves Pump Calcs and Sizing

description

Week 1 Unit Conversions Mass and Volume Flow Ideal Gas Newtonian Fluids, Reynolds No . Week 2 Pressure Loss in Pipe Flow Pressure Loss Examples Flow Measurement and Valves Pump Calcs and Sizing. - PowerPoint PPT Presentation

Transcript of Week 1 Unit Conversions Mass and Volume Flow Ideal Gas Newtonian Fluids, Reynolds No . Week 2

Page 1: Week 1 Unit Conversions Mass and Volume Flow Ideal  Gas Newtonian Fluids, Reynolds No . Week 2

Week 1Unit ConversionsMass and Volume FlowIdeal GasNewtonian Fluids, Reynolds No.

Week 2Pressure Loss in Pipe FlowPressure Loss ExamplesFlow Measurement and ValvesPump Calcs and Sizing

Page 2: Week 1 Unit Conversions Mass and Volume Flow Ideal  Gas Newtonian Fluids, Reynolds No . Week 2

4 m3 of wort is transferred from a kettle through a 100 m long, 4 cm diameter pipe with a roughness of 0.01 mm. The wort flows at an average velocity of 1.2 m/s and assume that its physical properties are the same as those of water (μ = 0.001 Pa.s).

a) Determine the time required to transfer all of the wort to the boil kettle, in min.

b) Determine the Reynolds Number.c) Determine the pressure drop in the pipe.

Page 3: Week 1 Unit Conversions Mass and Volume Flow Ideal  Gas Newtonian Fluids, Reynolds No . Week 2

Friction Losses in Pipes

found on Moody Chart handout

Determine the pressure drop of water, moving through a 5 cm diameter, 100 m long pipe at an average velocity of 5 m/s. The density of the water is 1000 kg/m3 and the viscosity is 0.001 Pa.s. The pipe roughness is 0.05 mm.

C f

P 2LDC f v

2

Page 4: Week 1 Unit Conversions Mass and Volume Flow Ideal  Gas Newtonian Fluids, Reynolds No . Week 2

Valves – Globe ValveSingle Seat

- Good general purpose- Good seal at shutoff

Double Seat- Higher flow rates- Poor shutoff (2 ports)

Three-way- Mixing or diverting- As disc adjusted, flow to one channel increased, flow to other decreased

Page 5: Week 1 Unit Conversions Mass and Volume Flow Ideal  Gas Newtonian Fluids, Reynolds No . Week 2

Valves – Butterfly Valve

Low Cost“Food Grade”Poor flow controlCan be automated

Page 6: Week 1 Unit Conversions Mass and Volume Flow Ideal  Gas Newtonian Fluids, Reynolds No . Week 2

Valves – Mix-proof Double SeatTwo separate sealing elements

keeping the two fluids separated.

Keeps fluids from mixingImmediate indication of failureAutomated, Sanitary appsEasier and Cheaper than

using many separate valves

Page 7: Week 1 Unit Conversions Mass and Volume Flow Ideal  Gas Newtonian Fluids, Reynolds No . Week 2
Page 8: Week 1 Unit Conversions Mass and Volume Flow Ideal  Gas Newtonian Fluids, Reynolds No . Week 2

Valves – Gate Valve

Little flow control, simple, reliable

Page 9: Week 1 Unit Conversions Mass and Volume Flow Ideal  Gas Newtonian Fluids, Reynolds No . Week 2

Valves – Ball Valve

Very little pressure loss, little flow control

Page 10: Week 1 Unit Conversions Mass and Volume Flow Ideal  Gas Newtonian Fluids, Reynolds No . Week 2

Valves – Brewery ApplicationsProduct Routing – Tight shutoff, material

compatibility, CIP criticalButterfly and mixproof

Service Routing – Tight shutoff and high temperature and pressure

Ball, Gate, GlobeFlow Control – Precise control of passage area

Globe (and needle), ButterflyPressure Relief – Control a downstream

pressure

Page 11: Week 1 Unit Conversions Mass and Volume Flow Ideal  Gas Newtonian Fluids, Reynolds No . Week 2

Flow Measurement Principle:Bernoulli Equation

Notice how this works for static fluids.

P 12v 2 gzConstant

Page 12: Week 1 Unit Conversions Mass and Volume Flow Ideal  Gas Newtonian Fluids, Reynolds No . Week 2

Flow Measurement – Orifice Meter

Cd accounts for frictional loss, 0.65Simple design, fabricationHigh turbulence, significant uncertainty

2

1

22

1

2

AA

P

ACV d

P1 P2

Page 13: Week 1 Unit Conversions Mass and Volume Flow Ideal  Gas Newtonian Fluids, Reynolds No . Week 2

Flow Meas. – Venturi Meter

Less frictional losses, Cd 0.95Low pressure drop, but expensiveHigher accuracy than orifice plate

2

1

22

1

2

AA

P

ACV d

P1P2

Page 14: Week 1 Unit Conversions Mass and Volume Flow Ideal  Gas Newtonian Fluids, Reynolds No . Week 2

Flow Meas. – Variable Area/Rotameter

Inexpensive, good flow rate indicatorGood for liquids or gasesNo remote sensing, limited accuracy

WeightDragForces

0 Cdrag12 Av 2 mg

vAV

Page 15: Week 1 Unit Conversions Mass and Volume Flow Ideal  Gas Newtonian Fluids, Reynolds No . Week 2

Flow Measurement - Pitot Tube

Direct velocity measurement (not flow rate)Measure P with gauge, transducer, or

manometer

P1

P2

1 2

2

2

21vPP

v

Page 16: Week 1 Unit Conversions Mass and Volume Flow Ideal  Gas Newtonian Fluids, Reynolds No . Week 2

Flow Measurement – Weir

Open channel flow, height determines flowInexpensive, good flow rate indicatorGood for estimating flow to sewerCan measure height using ultrasonic meter

Page 17: Week 1 Unit Conversions Mass and Volume Flow Ideal  Gas Newtonian Fluids, Reynolds No . Week 2

Flow Measurement – Thermal Mass

Measure gas or liquid temperature upstream and downstream of heater

Must know specific heat of fluidKnow power going to heaterCalculate flow rate

Page 18: Week 1 Unit Conversions Mass and Volume Flow Ideal  Gas Newtonian Fluids, Reynolds No . Week 2

Flow Measurement – Magnetic

Faradays LawMagnetic field applied to the tubeVoltage created proportional to velocityRequires a conducting fluid (non-DI water)

Page 19: Week 1 Unit Conversions Mass and Volume Flow Ideal  Gas Newtonian Fluids, Reynolds No . Week 2

Flow Measurement – Magnetic

Page 20: Week 1 Unit Conversions Mass and Volume Flow Ideal  Gas Newtonian Fluids, Reynolds No . Week 2

Pumps

z = static headhf = head loss due to friction

Pump

fss

ss hρgP

zh HeadSuction

Suction Delivery

fdd

dd hρgP

zh HeadDelivery

fsfdsd

sdsd hhρg

PPzzhh Head Total

Page 21: Week 1 Unit Conversions Mass and Volume Flow Ideal  Gas Newtonian Fluids, Reynolds No . Week 2

PumpsDistanceForceWork

DistanceAreaAreaForceWork

timeDistanceArea

AreaForce

timeWorkPower

Flowrate VolumeΔPPower

ghVPV Output Power

Efficiency PumpOutputPower InputPower

Page 22: Week 1 Unit Conversions Mass and Volume Flow Ideal  Gas Newtonian Fluids, Reynolds No . Week 2

PumpsCalculate the theoretical pump power

required to raise 1000 m3 per day of water from 1 bar to 16 bar pressure.

If the pump efficiency is 55%, calculate the shaft power required.

Denisity of Water = 1000 kg/m3

1 bar = 100 kPa

Page 23: Week 1 Unit Conversions Mass and Volume Flow Ideal  Gas Newtonian Fluids, Reynolds No . Week 2

PumpsA pump, located at the outlet of tank A,must transfer 10 m3 of fluid into tank B in 20 minutes. The water level in tank A is 3 m above the pump, the piperoughness is 0.05 mm, and the pumpefficiency is 55%. The fluid density is 975 kg/m3 and the viscosity is 0.00045Pa.s. Both tanks are at atmosphericpressure. Determine the total head andpump input and output power.

Tank A

Tank B

8 m

15 m

4 m

Pipe Diameter, 50

mm

Fittings = 5 m

Page 24: Week 1 Unit Conversions Mass and Volume Flow Ideal  Gas Newtonian Fluids, Reynolds No . Week 2

Pumps

Need Available NPSH > Pump Required NPSHAvoid Cavitationz = static headhf = head loss due to friction

fs

v hP

ρg

Pz NPSH Available ps

s

Page 25: Week 1 Unit Conversions Mass and Volume Flow Ideal  Gas Newtonian Fluids, Reynolds No . Week 2

PumpsA pump, located at the outlet of tank A,must transfer 10 m3 of fluid into tank B in 20 minutes. The water level in tank A is 3 m above the pump, the piperoughness is 0.05 mm, and the pumpefficiency is 55%. The fluid density is 975 kg/m3 and the viscosity is 0.00045Pa.s. The vapor pressure is 50 kPa andthe tank is at atmospheric pressure.Determine the available NPSH.

Tank A

Tank B

8 m

15 m

4 m

Pipe Diameter, 50

mm

Fittings = 5 m

Page 26: Week 1 Unit Conversions Mass and Volume Flow Ideal  Gas Newtonian Fluids, Reynolds No . Week 2

Pump Sizing1. Volume Flow Rate (m3/hr or gpm) 2. Total Head, h (m or ft)

2a. P (bar, kPa, psi)3. Power Output (kW or hp)4. NPSH Required

hgP

Page 27: Week 1 Unit Conversions Mass and Volume Flow Ideal  Gas Newtonian Fluids, Reynolds No . Week 2

PumpsCentrifugal

Impeller spinning inside fluidKinetic energy to pressureFlow controlled by Pdelivery

Positive DisplacementFlow independent of Pdelivery

Many configurations

Page 28: Week 1 Unit Conversions Mass and Volume Flow Ideal  Gas Newtonian Fluids, Reynolds No . Week 2

Centrifugal Pumps

Constantρgzρv21P 2

Impeller

SuctionVolute Casting

Delivery

Page 29: Week 1 Unit Conversions Mass and Volume Flow Ideal  Gas Newtonian Fluids, Reynolds No . Week 2

Centrifugal PumpsFlow accelerated (forced by impeller)Then, flow decelerated (pressure increases)Low pressure at center “draws” in fluidPump should be full of liquid at all timesFlow controlled by delivery side valveMay operate against closed valveSeal between rotating shaft and casing

Page 30: Week 1 Unit Conversions Mass and Volume Flow Ideal  Gas Newtonian Fluids, Reynolds No . Week 2

Centrifugal PumpsAdvantages

Simple construction, many materialsNo valves, can be cleaned in placeRelatively inexpensive, low maintenanceSteady delivery, versatileOperates at high speed (electric motor)Wide operating range (flow and head)

DisadvantagesMultiple stages needed for high pressuresPoor efficiency for high viscosity fluidsMust prime pump

Page 31: Week 1 Unit Conversions Mass and Volume Flow Ideal  Gas Newtonian Fluids, Reynolds No . Week 2

Centrifugal PumpsH-V Chart

Head

(or P)

Volume Flow Rate

Increasing Impeller Diameter

A B C

Page 32: Week 1 Unit Conversions Mass and Volume Flow Ideal  Gas Newtonian Fluids, Reynolds No . Week 2

Centrifugal PumpsH-Q Chart

Head

(or P)

Volume Flow Rate

A B C

Increasing Efficiency

Required NPSH

Page 33: Week 1 Unit Conversions Mass and Volume Flow Ideal  Gas Newtonian Fluids, Reynolds No . Week 2

Centrifugal PumpsH-Q Chart

Head

(or P)

Volume Flow Rate

A B C

Page 34: Week 1 Unit Conversions Mass and Volume Flow Ideal  Gas Newtonian Fluids, Reynolds No . Week 2

Centrifugal PumpsH-Q Chart

Head

(or P)

Volume Flow Rate

Required Flow

CapacityActual Flow

Capacity

Required Power

Page 35: Week 1 Unit Conversions Mass and Volume Flow Ideal  Gas Newtonian Fluids, Reynolds No . Week 2

Pressure Drop Example

Water flows through a 10 cm diameter, 300 m long pipe at a velocity of 2 m/s. The density is 1000 kg/m3, the viscosity is 0.001 Pa.s and the pipe roughness is 0.01 mm. Determine:

a. Volume flow rate, in m3/sb. Mass flow rate in kg/sc. Pressure loss through the pipe, in Pad. Head loss through the pipe meters