We would recommend the use of a Flexible Hose FIXING ADVICE … · 2016. 12. 17. · 73055...

1
WC-F26R 170mm - 410mm Code: WC-F23R 140mm - 290mm Code: WC-F18R 100mm - 160mm EFFECTIVE LENGTH MIN/MAX EFFECTIVE LENGTH MIN/MAX Code: WC-F26S 170mm - 410mm Code: WC-F23S 140mm - 290mm Code: WC-F18S 100mm - 160mm Code: WC-F26P 160mm - 380mm Code: WC-F23P 130mm - 260mm Code: WC-CON8F18 190mm - 270mm Code: WC-CON8F 220mm - 400mm Code: STANDARD CONNECTORS WC-F26RV 180mm - 380mm Code: WC-F23RV 150mm - 280mm Code: WC-F26SV 180mm - 380mm Code: WC-F23SV 150mm - 280mm Code: WC-F26PV 170mm - 380mm Code: WC-F23PV 140mm - 260mm Code: WC-CON8FV 220mm - 400mm Code: CONNECTORS WITH 1 1 /4" UNIVERSAL BOSS 25mm 25mm EFFECTIVE LENGTH MIN/MAX EFFECTIVE LENGTH MIN/MAX Effective length Effective length Effective length Effective length Effective length Effective length Effective length Effective length 22.5mm 26mm 45mm Flexible WC Connectors All inlet seals will fit 97-107mm diameter pan spigot. WC-F18R : WC-F23R : WC-F26R : WC-F23RV : WC-F26RV : WC-CON8F and WC-CON8FV fit inside 4"/110mm diameter pipe. WC-F18S : WC-F23S : WC-F26S : WC-F23SV and WC-F26SV fit inside 3 1 /2"/90mm diameter pipe. Connectors with a plain end have an outside diameter of 110mm. All Connectors with 1 1 /4" Universal Boss include Blank Cap with 1 1 /2" BSP Thread. Installations requiring an extended straight length should be supported firmly to prevent any sagging. Do not attempt to clear blockages with the use of drain rods. WHEN INSTALLING THE WC CONNECTOR TO THE WC PAN SPIGOT WE RECOMMEND THAT THE INLET SOCKET OF THE CONNECTOR BE LUBRICATED WITH CLEAN WATER THEN PUSHED FIRMLY ON TO THE SPIGOT OF THE WC PAN. THE SOIL PIPE TO BE CONNECTED TO THE CONNECTOR OUTLET SHOULD BE CUT SQUARE AND FREE OF ANY DEBRIS. THE FINNED SEAL SPIGOT OUTLET OF THE WC CONNECTOR MAY BE LUBRICATED WITH SILICONE GREASE TO AID ISTALLATION INTO THE INTERNAL DIAMETER OF THE SOIL PIPE. Do not over extend or pull flex off inlet and outlet locations. Extend flex by pulling from the middle of the flex and not from the fixture locations. Rigid, Flexible and MACFIT WC Connectors FIXING INSTRUCTIONS & DIMENSIONAL LEAFLET McALPINE & CO. LTD., Kelvin Avenue, Hillington, Glasgow G52 4LF. Telephone: 0141-882 3213 Fax: 0141-891 5065 Fax: Orders (Sales Office) 0141-883 5697 Website: www.mcalpineplumbing.com © McAlpine & Co. Ltd. July 2016 L-WC-CON WC CONNECTOR WALL FLANGES ANTI CROSS-FLOW AND RODENT BARRIER VALVE WC17-114 114mm Code: WC17-110 110mm Code: WC17-90 90mm Code: ARB-1 Code: TO FIT PIPE 170mm 40mm WC-F21R 140mm - 280mm* Code: FLEXIBLE WC CONNECTORS FOR BACK TO WALL WC PANS TO FIT OVER PIPE SIZE WC-F21S 140mm - 280mm* Code: We would recommend the use of a Flexible Hose Clip Driver as illustrated to tighten the jubilee clip. (Standard 7mm driver for hose clips as shown). Please note: When these products are used on excessively misshapen pan outlet spigots, the use of silicone sealant can be an advantage to ensure an air and water tight seal is achieved. FLEXIBLE HOSE CLIP DRIVER FIXING ADVICE Tested to BS5627: 1984. Tests prove conclusively that there is no build-up of sediment. Keep sharp tools and abrasive materials away from flexible pipe. WHEN INSTALLING THE WC CONNECTOR TO THE WC PAN SPIGOT WE RECOMMEND THAT THE INLET SOCKET OF THE CONNECTOR BE LUBRICATED WITH CLEAN WATER THEN PUSHED FIRMLY ON TO THE SPIGOT OF THE WC PAN. THE SOIL PIPE TO BE CONNECTED TO THE CONNECTOR OUTLET SHOULD BE CUT SQUARE AND FREE OF ANY DEBRIS. THE FINNED SEAL SPIGOT OUTLET OF THE WC CONNECTOR MAY BE LUBRICATED WITH SILICONE GREASE TO AID INSTALLATION INTO THE INTERNAL DIAMETER OF THE SOIL PIPE. Do not over tighten the jubilee clip. Power tools must not be used to tighten the jubilee clip. Do not over extend or pull over the recommended length. Installations requiring an extended straight length should be supported. Ensure all joints are secure before final fix of the WC pan. Do not attempt to clear blockages with the use of drain rods. Effective length Effective length WC-CON8F18-BTW 170mm - 250mm* Code: WC-CON8F-BTW 230mm - 480mm* Code: WC-CON8F18-S-BTW 170mm - 250mm* Code: WC-CON8F-S-BTW 230mm - 480mm* Code: Effective length Effective length * EFFECTIVE LENGTH MIN/MAX STRAIGHT EXTENSION CUT TO LENGTH REQUIRED WC-CON-EXT Code: 86mm 10mm Offset Extension Reducer. Adjustable Length. Code: WC-EXTD 10mm Offset Extension Adjustable Length. Code: WC-EXTC Straight Extension Reducer. Adjustable Length. Code: WC-EXTB Straight Extension. Adjustable Length. Code: WC-EXTA 45° Angle. Code: WC-CON16 90° Space Saving Bend. Adjustable Length. Code: WC-CONQP Tested to BS 5627 : 1984 Inlet seals will fit Pans manufactured to BS 5503/4 and BS 1213. Outlet seals will fit inside 4"/110mm diameter pipe except MAC-EXTB which fits inside 3 1 / 2 "/90mm pipe and MAC-EXTC which fits inside 3"/75mm pipe. MACFIT (patent pending) WC Connectors Manufactured in EVA Code: MAC-EXTA Straight. 4"/110mm Outlet. Code: MAC-1 20mm Offset. 4"/110mm Outlet. Code: MAC-4 14º Angle. 4"/110mm Outlet. Code: MAC-7A 90º Bend. 4"/110mm Outlet. Non Adjustable. Code: MAC-8 Code: MAC-8L 90º Bend (Long). 4"/110mm Outlet. Non Adjustable. Code: MAC-EXTB Code: MAC-EXTC Linking Connector (Polypropylene). Code: MACLINK Straight. 3 1 /2"/90mm Outlet. Code: MAC-3 Straight Extension. 4"/110mm Outlet. Straight Extension. 3 1 /2"/90mm Outlet. Straight Extension. 3"/75mm Outlet. 40mm Offset. 4"/110mm Outlet. Code: MAC-4A Straight. Code: WC-CON1 Straight. 1 1 /4" Universal Pipe Boss, including Blanking Cap with 1 1 /2" BSP Thread. Code: WC-CON1V Straight. Adjustable Length. Code: WC-CON2 Straight Reducer. Adjustable Length. Code: WC-CON2B Straight. Adjustable Length. Code: WC-CON3 20mm Offset. Code: WC-CON4 40mm Offset. Code: WC-CON4A 40mm Offset. Code: WC-CON4B 20mm Offset. Adjustable Length. Code: WC-CON5 24mm Offset Reducer. Adjustable Length. Code: WC-CON5B 90º Bend. 1 1 /4" Universal Pipe Boss, including Blanking Cap, with 1 1 /2" BSP Thread. Adjustable Length. Code: WC-CON8V 90º Bend. Adjustable Length. Code: WC-CON9 90º Bend. 1 1 /4" Universal Pipe Boss, including Blanking Cap, with 1 1 /2" BSP Thread. Adjustable Length. Code: WC-CON9V 90º Space Saving Bend. Adjustable Length. Code: WC-CONQ 14º Angle Reducer. Adjustable Length. Code: WC-CON7B 14º Angle. Code: WC-CON7A 14º Angle. Adjustable Length. Code: WC-CON7 10mm Offset. Adjustable Length. Code: WC-CON6 90º Bend. Adjustable Length. Code: WC-CON8 Code: WC-CON8E 10mm 240mm 85mm Tested to BS5627. All inlet seals will fit 97-107mm diameter pan spigot. All outlet seals will fit inside 4"/110mm diameter pipe except WC-CON2B, WC-CON5B, WC-CON7B, WC-EXTB and WC-EXTD which fit inside 3 1 / 2 "/90mm diameter pipe. Connectors with a plain end have an outside diameter of 110mm. Rigid WC Connectors WHEN INSTALLING THE WC CONNECTOR TO THE WC PAN SPIGOT WE RECOMMEND THAT THE INLET SOCKET OF THE CONNECTOR BE LUBRICATED WITH CLEAN WATER THEN PUSHED FIRMLY ON TO THE SPIGOT OF THE WC PAN. THE SOIL PIPE TO BE CONNECTED TO THE CONNECTOR OUTLET SHOULD BE CUT SQUARE AND FREE OF ANY DEBRIS. THE FINNED SEAL SPIGOT OUTLET OF THE WC CONNECTOR MAY BE LUBRICATED WITH SILICONE GREASE TO AID ISTALLATION INTO THE INTERNAL DIAMETER OF THE SOIL PIPE. WHEN INSTALLING THE WC CONNECTOR TO THE WC PAN SPIGOT WE RECOMMEND THAT THE INLET SOCKET OF THE CONNECTOR BE LUBRICATED WITH CLEAN WATER THEN PUSHED FIRMLY ON TO THE SPIGOT OF THE WC PAN. THE SOIL PIPE TO BE CONNECTED TO THE CONNECTOR OUTLET SHOULD BE CUT SQUARE AND FREE OF ANY DEBRIS. THE FINNED SEAL SPIGOT OUTLET OF THE WC CONNECTOR MAY BE LUBRICATED WITH SILICONE GREASE TO AID ISTALLATION INTO THE INTERNAL DIAMETER OF THE SOIL PIPE.

Transcript of We would recommend the use of a Flexible Hose FIXING ADVICE … · 2016. 12. 17. · 73055...

Page 1: We would recommend the use of a Flexible Hose FIXING ADVICE … · 2016. 12. 17. · 73055 ConMcalpine RED July 2016 FRONT 24/06/2016 09:21 Page 1 Rigid, Flexible and MACFIT WC Connectors

Rigid, Flexibleand MACFIT

WC ConnectorsFIXING INSTRUCTIONS& DIMENSIONAL LEAFLET

McALPINE & CO. LTD.,Kelvin Avenue, Hillington,

Glasgow G52 4LF.Telephone: 0141-882 3213

Fax: 0141-891 5065Fax: Orders (Sales Office) 0141-883 5697Website: www.mcalpineplumbing.com

© McAlpine & Co. Ltd. July 2016L-WC-CON

WC CONNECTOR WALL FLANGES

ANTI CROSS-FLOW ANDRODENT BARRIER VALVE

WC17-114114mm Code:

WC17-110110mm Code:

WC17-9090mm Code:

ARB-1 Code:

TO

FIT

PIP

E

170mm

40mm

WC-F21R

140mm - 280mm*

Code:

FLEXIBLE WC CONNECTORS FOR BACK TO WALL WC PANS

TO FIT OVERPIPE SIZE

WC-F21S

140mm - 280mm*

Code:

WC-F26R 170mm - 410mmCode:

WC-F23R 140mm - 290mmCode:

WC-F18R 100mm - 160mm

EFFECTIVE LENGTHMIN/MAX

EFFECTIVE LENGTHMIN/MAX

Code:

WC-F26S 170mm - 410mmCode:

WC-F23S 140mm - 290mmCode:

WC-F18S 100mm - 160mmCode:

WC-F26P 160mm - 380mmCode:

WC-F23P 130mm - 260mmCode:

WC-CON8F18 190mm - 270mmCode:

WC-CON8F 220mm - 400mmCode:

STANDARD CONNECTORS

WC-F26RV 180mm - 380mmCode:

WC-F23RV 150mm - 280mmCode:

WC-F26SV 180mm - 380mmCode:

WC-F23SV 150mm - 280mmCode:

WC-F26PV 170mm - 380mmCode:

WC-F23PV 140mm - 260mmCode:

WC-CON8FV 220mm - 400mmCode:

CONNECTORS WITH 11/4" UNIVERSAL BOSS

25mm

25mmEFFECTIVE LENGTH

MIN/MAXEFFECTIVE LENGTH

MIN/MAX

We would recommend the use of a Flexible HoseClip Driver as illustrated to tighten the jubilee clip.(Standard 7mm driver for hose clips as shown).

Please note: When these products are used on excessively misshapen pan outlet spigots, the use of silicone sealant can bean advantage to ensure an air and water tight seal is achieved. FLEXIBLE HOSE CLIP DRIVER

FIXING ADVICE

■Tested to BS5627: 1984.

■Tests prove conclusively that there is no build-up of sediment.

■Keep sharp tools and abrasive materials away from flexible pipe.

■WHEN INSTALLING THE WC CONNECTOR TO THE WC PANSPIGOT WE RECOMMEND THAT THE INLET SOCKET OF THECONNECTOR BE LUBRICATED WITH CLEAN WATER THENPUSHED FIRMLY ON TO THE SPIGOT OF THE WC PAN. THE SOILPIPE TO BE CONNECTED TO THE CONNECTOR OUTLETSHOULD BE CUT SQUARE AND FREE OF ANY DEBRIS. THEFINNED SEAL SPIGOT OUTLET OF THE WC CONNECTOR MAY BELUBRICATED WITH SILICONE GREASE TO AID INSTALLATIONINTO THE INTERNAL DIAMETER OF THE SOIL PIPE.

■Do not over tighten the jubilee clip.

■Power tools must not be used to tighten the jubilee clip.

■Do not over extend or pull over the recommended length.

■Installations requiring an extended straight length shouldbe supported.

■Ensure all joints are secure before final fix of the WC pan.

■Do not attempt to clear blockages with the use of drain rods.

Effective length

Effective length

Effective length

Effective length

Effective length

Effe

ctiv

e le

ngth

Effective length

Effective length

Effective length

Eff

ectiv

e le

ngth

22.5

mm

26m

m45

mm

WC-CON8F18-BTW

170mm - 250mm*

Code:

WC-CON8F-BTW

230mm - 480mm*

Code:

WC-CON8F18-S-BTW

170mm - 250mm*

Code:

WC-CON8F-S-BTW

230mm - 480mm*

Code:

Effective length

Effective length

* EFFECTIVE LENGTHMIN/MAX

STRAIGHT EXTENSION

CUT TO LENGTH REQUIRED

WC-CON-EXT Code:

Flexible WC Connectors• All inlet seals will fit 97-107mm diameter

pan spigot.• WC-F18R : WC-F23R : WC-F26R : WC-F23RV :

WC-F26RV : WC-CON8F and WC-CON8FV fitinside 4"/110mm diameter pipe.

• WC-F18S : WC-F23S : WC-F26S : WC-F23SV andWC-F26SV fit inside 31/2"/90mm diameter pipe.

• Connectors with a plain end have an outside diameter of 110mm.

• All Connectors with 11/4" Universal Bossinclude Blank Cap with 11/2" BSP Thread.

• Installations requiring an extended straightlength should be supported firmly to preventany sagging.

• Do not attempt to clear blockages with the use of drain rods.

• WHEN INSTALLING THE WC CONNECTOR TO THEWC PAN SPIGOT WE RECOMMEND THAT THE INLETSOCKET OF THE CONNECTOR BE LUBRICATED WITHCLEAN WATER THEN PUSHED FIRMLY ON TO THESPIGOT OF THE WC PAN. THE SOIL PIPE TO BECONNECTED TO THE CONNECTOR OUTLET SHOULDBE CUT SQUARE AND FREE OF ANY DEBRIS. THEFINNED SEAL SPIGOT OUTLET OF THE WCCONNECTOR MAY BE LUBRICATED WITH SILICONEGREASE TO AID ISTALLATION INTO THE INTERNALDIAMETER OF THE SOIL PIPE.

• Do not over extend or pull flex off inletand outlet locations. Extend flex by pulling fromthe middle of the flex and not from the fixture locations.

86mm

73055 ConMcalpine RED July 2016 FRONT 24/06/2016 09:21 Page 1

Rigid, Flexibleand MACFIT

WC ConnectorsFIXING INSTRUCTIONS& DIMENSIONAL LEAFLET

McALPINE & CO. LTD.,Kelvin Avenue, Hillington,

Glasgow G52 4LF.Telephone: 0141-882 3213

Fax: 0141-891 5065Fax: Orders (Sales Office) 0141-883 5697Website: www.mcalpineplumbing.com

© McAlpine & Co. Ltd. July 2016 L-WC-CON

WC CONNECTOR WALL FLANGES

ANTI CROSS-FLOW ANDRODENT BARRIER VALVE

WC17-114 114mmCode:

WC17-110 110mmCode:

WC17-90 90mmCode:

ARB-1Code:

TO

FIT

PIP

E

170m

m

40mm

WC-F21R

140mm - 280mm*

Code:

FLEXIBLE WC CONNECTORS FOR BACK TO WALL WC PANS

TO FIT OVERPIPE SIZE

WC-F21S

140mm - 280mm*

Code:

WC-F26R170mm - 410mm Code:

WC-F23R140mm - 290mm Code:

WC-F18R100mm - 160mm

EFFECTIVE LENGTHMIN/MAX

EFFECTIVE LENGTHMIN/MAX

Code:

WC-F26S170mm - 410mm Code:

WC-F23S140mm - 290mm Code:

WC-F18S100mm - 160mm Code:

WC-F26P160mm - 380mm Code:

WC-F23P130mm - 260mm Code:

WC-CON8F18190mm - 270mm Code:

WC-CON8F220mm - 400mm Code:

STANDARD CONNECTORS

WC-F26RV180mm - 380mm Code:

WC-F23RV150mm - 280mm Code:

WC-F26SV180mm - 380mm Code:

WC-F23SV150mm - 280mm Code:

WC-F26PV170mm - 380mm Code:

WC-F23PV140mm - 260mm Code:

WC-CON8FV220mm - 400mm Code:

CONNECTORS WITH 11/4"UNIVERSAL BOSS

25mm

25mmEFFECTIVE LENGTH

MIN/MAXEFFECTIVE LENGTH

MIN/MAX

We would recommend the use of a Flexible HoseClip Driver as illustrated to tighten the jubilee clip.(Standard 7mm driver for hose clips as shown).

Please note: When these products are used on excessively misshapen pan outlet spigots, the use of silicone sealant can bean advantage to ensure an air and water tight seal is achieved.FLEXIBLE HOSE CLIP DRIVER

FIXING ADVICE

■ Tested to BS5627: 1984.

■ Tests prove conclusively that there is no build-up of sediment.

■ Keep sharp tools and abrasive materials away from flexible pipe.

■ WHEN INSTALLING THE WC CONNECTOR TO THE WC PANSPIGOT WE RECOMMEND THAT THE INLET SOCKET OF THECONNECTOR BE LUBRICATED WITH CLEAN WATER THENPUSHED FIRMLY ON TO THE SPIGOT OF THE WC PAN. THE SOILPIPE TO BE CONNECTED TO THE CONNECTOR OUTLETSHOULD BE CUT SQUARE AND FREE OF ANY DEBRIS. THEFINNED SEAL SPIGOT OUTLET OF THE WC CONNECTOR MAY BELUBRICATED WITH SILICONE GREASE TO AID INSTALLATIONINTO THE INTERNAL DIAMETER OF THE SOIL PIPE.

■ Do not over tighten the jubilee clip.

■ Power tools must not be used to tighten the jubilee clip.

■ Do not over extend or pull over the recommended length.

■ Installations requiring an extended straight length shouldbe supported.

■ Ensure all joints are secure before final fix of the WC pan.

■ Do not attempt to clear blockages with the use of drain rods.

Effective length

Effective length

Effective length

Effective length

Effective length

Effective length

Effective length

Effective length

Effective length

Effective length

22.5mm

26mm

45mm

WC-CON8F18-BTW

170mm - 250mm*

Code:

WC-CON8F-BTW

230mm - 480mm*

Code:

WC-CON8F18-S-BTW

170mm - 250mm*

Code:

WC-CON8F-S-BTW

230mm - 480mm*

Code:

Effe

ctiv

e le

ngth

Effe

ctiv

e le

ngth

* EFFECTIVE LENGTHMIN/MAX

STRAIGHT EXTENSION

CUT TO LENGTH REQUIRED

WC-CON-EXTCode:

Flexible WC Connectors•All inlet seals will fit 97-107mm diameter

pan spigot.•WC-F18R : WC-F23R : WC-F26R : WC-F23RV :

WC-F26RV : WC-CON8F and WC-CON8FV fitinside 4"/110mm diameter pipe.

•WC-F18S : WC-F23S : WC-F26S : WC-F23SV andWC-F26SV fit inside 31/2"/90mm diameter pipe.

•Connectors with a plain end have an outside diameter of 110mm.

•All Connectors with 11/4" Universal Bossinclude Blank Cap with 11/2" BSP Thread.

•Installations requiring an extended straightlength should be supported firmly to preventany sagging.

•Do not attempt to clear blockages with the use of drain rods.

•WHEN INSTALLING THE WC CONNECTOR TO THEWC PAN SPIGOT WE RECOMMEND THAT THE INLETSOCKET OF THE CONNECTOR BE LUBRICATED WITHCLEAN WATER THEN PUSHED FIRMLY ON TO THESPIGOT OF THE WC PAN. THE SOIL PIPE TO BECONNECTED TO THE CONNECTOR OUTLET SHOULDBE CUT SQUARE AND FREE OF ANY DEBRIS. THEFINNED SEAL SPIGOT OUTLET OF THE WCCONNECTOR MAY BE LUBRICATED WITH SILICONEGREASE TO AID ISTALLATION INTO THE INTERNALDIAMETER OF THE SOIL PIPE.

•Do not over extend or pull flex off inletand outlet locations. Extend flex by pulling fromthe middle of the flex and not from the fixture locations.

86mm

73055 ConMcalpine RED July 2016 FRONT 24/06/2016 09:21 Page 1

10mm Offset ExtensionReducer.Adjustable Length.

Code: WC-EXTD

10mm Offset ExtensionAdjustable Length.

Code: WC-EXTC

Straight ExtensionReducer.Adjustable Length.

Code: WC-EXTB

Straight Extension.Adjustable Length.

Code: WC-EXTA

45° Angle.

Code: WC-CON16

90° Space Saving Bend.Adjustable Length.

Code: WC-CONQP• Tested to BS 5627 : 1984• Inlet seals will fit Pans manufactured to

BS 5503/4 and BS 1213.• Outlet seals will fit inside 4"/110mm

diameter pipe except MAC-EXTB which fitsinside 31/2"/90mm pipe and MAC-EXTCwhich fits inside 3"/75mm pipe.

MACFIT(patent pending)

WC ConnectorsManufactured in EVA

Code: MAC-EXTA

Straight.4"/110mm Outlet.

Code: MAC-1

20mm Offset.4"/110mm Outlet.

Code: MAC-4

14º Angle.4"/110mm Outlet.

Code: MAC-7A

90º Bend.4"/110mm Outlet.Non Adjustable.

Code: MAC-8

Code: MAC-8L

90º Bend (Long).4"/110mm Outlet.Non Adjustable.

Code: MAC-EXTB

Code: MAC-EXTC

Linking Connector(Polypropylene).

Code: MACLINK

Straight.31/2"/90mm Outlet.

Code: MAC-3

Straight Extension.4"/110mm Outlet.

Straight Extension.31/2"/90mm Outlet.

Straight Extension.3"/75mm Outlet.

40mm Offset.4"/110mm Outlet.

Code: MAC-4A

Straight.

Code: WC-CON1

Straight. 11/4" UniversalPipe Boss, includingBlanking Cap with 11/2"BSP Thread.

Code: WC-CON1V

Straight.Adjustable Length.

Code: WC-CON2

Straight Reducer.Adjustable Length.

Code: WC-CON2B

Straight.Adjustable Length.

Code: WC-CON3

20mm Offset.

Code: WC-CON4

40mm Offset.

Code: WC-CON4A

40mm Offset.

Code: WC-CON4B

20mm Offset.Adjustable Length.

Code: WC-CON5

24mm Offset Reducer.Adjustable Length.

Code: WC-CON5B

90º Bend. 11/4" UniversalPipe Boss, includingBlanking Cap, with 11/2"BSP Thread.Adjustable Length.

Code: WC-CON8V

90º Bend.Adjustable Length.

Code: WC-CON9

90º Bend. 11/4" UniversalPipe Boss, includingBlanking Cap, with 11/2"BSP Thread.Adjustable Length.

Code: WC-CON9V

90º Space Saving Bend.Adjustable Length.

Code: WC-CONQ

14º Angle Reducer.Adjustable Length.

Code: WC-CON7B

14º Angle.

Code: WC-CON7A

14º Angle.Adjustable Length.

Code: WC-CON7

10mm Offset.Adjustable Length.

Code: WC-CON6

9 0 º B e n d . A d j u s t a b l e L e n g t h .

Code: WC-CON8 Code: WC-CON8E

10mm

240mm

85mm

• Tested to BS5627.• All inlet seals will fit 97-107mm diameter

pan spigot.• All outlet seals will fit inside 4"/110mm

diameter pipe except WC-CON2B,WC-CON5B, WC-CON7B, WC-EXTB andWC-EXTD which fit inside 31/2"/90mmdiameter pipe.

• Connectors with a plain end have anoutside diameter of 110mm.

Rigid WC Connectors

WHEN INSTALLING THE WC CONNECTOR TO THE WC PAN SPIGOT WE RECOMMEND THAT THE INLET SOCKET OF THE CONNECTOR BE LUBRICATED WITH CLEAN WATER THEN PUSHED FIRMLY ON TO THE SPIGOT OF THE WC PAN. THE SOIL PIPE TO BE CONNECTED TO THE CONNECTOR OUTLET SHOULD BE CUT SQUARE AND FREE OF ANY DEBRIS. THE FINNED SEAL SPIGOT OUTLET OF THE WC CONNECTOR MAY BE LUBRICATED WITH SILICONE GREASE TO AID ISTALLATION INTO THE INTERNAL DIAMETER OF THE SOIL PIPE.

WHEN INSTALLING THE WC CONNECTOR TO THE WC PAN SPIGOT WE RECOMMEND THAT THE INLET SOCKET OF THE CONNECTOR BE LUBRICATED WITH CLEAN WATER THEN PUSHED FIRMLY ON TO THE SPIGOT OF THE WC PAN. THE SOIL PIPE TO BE CONNECTED TO THE CONNECTOR OUTLET SHOULD BE CUT SQUARE AND FREE OF ANY DEBRIS. THE FINNED SEAL SPIGOT OUTLET OF THE WC CONNECTOR MAY BE LUBRICATED WITH SILICONE GREASE TO AID ISTALLATION INTO THE INTERNAL DIAMETER OF THE SOIL PIPE.

73055 ConMcalpine RED July 2016 BACK 24/06/2016 09:21 Page 1