Flexible Learning Year Application 2013-2016 Presentation at Public Hearings.
We would recommend the use of a Flexible Hose FIXING ADVICE … · 2016. 12. 17. · 73055...
Transcript of We would recommend the use of a Flexible Hose FIXING ADVICE … · 2016. 12. 17. · 73055...
Rigid, Flexibleand MACFIT
WC ConnectorsFIXING INSTRUCTIONS& DIMENSIONAL LEAFLET
McALPINE & CO. LTD.,Kelvin Avenue, Hillington,
Glasgow G52 4LF.Telephone: 0141-882 3213
Fax: 0141-891 5065Fax: Orders (Sales Office) 0141-883 5697Website: www.mcalpineplumbing.com
© McAlpine & Co. Ltd. July 2016L-WC-CON
WC CONNECTOR WALL FLANGES
ANTI CROSS-FLOW ANDRODENT BARRIER VALVE
WC17-114114mm Code:
WC17-110110mm Code:
WC17-9090mm Code:
ARB-1 Code:
TO
FIT
PIP
E
170mm
40mm
WC-F21R
140mm - 280mm*
Code:
FLEXIBLE WC CONNECTORS FOR BACK TO WALL WC PANS
TO FIT OVERPIPE SIZE
WC-F21S
140mm - 280mm*
Code:
WC-F26R 170mm - 410mmCode:
WC-F23R 140mm - 290mmCode:
WC-F18R 100mm - 160mm
EFFECTIVE LENGTHMIN/MAX
EFFECTIVE LENGTHMIN/MAX
Code:
WC-F26S 170mm - 410mmCode:
WC-F23S 140mm - 290mmCode:
WC-F18S 100mm - 160mmCode:
WC-F26P 160mm - 380mmCode:
WC-F23P 130mm - 260mmCode:
WC-CON8F18 190mm - 270mmCode:
WC-CON8F 220mm - 400mmCode:
STANDARD CONNECTORS
WC-F26RV 180mm - 380mmCode:
WC-F23RV 150mm - 280mmCode:
WC-F26SV 180mm - 380mmCode:
WC-F23SV 150mm - 280mmCode:
WC-F26PV 170mm - 380mmCode:
WC-F23PV 140mm - 260mmCode:
WC-CON8FV 220mm - 400mmCode:
CONNECTORS WITH 11/4" UNIVERSAL BOSS
25mm
25mmEFFECTIVE LENGTH
MIN/MAXEFFECTIVE LENGTH
MIN/MAX
We would recommend the use of a Flexible HoseClip Driver as illustrated to tighten the jubilee clip.(Standard 7mm driver for hose clips as shown).
Please note: When these products are used on excessively misshapen pan outlet spigots, the use of silicone sealant can bean advantage to ensure an air and water tight seal is achieved. FLEXIBLE HOSE CLIP DRIVER
FIXING ADVICE
■Tested to BS5627: 1984.
■Tests prove conclusively that there is no build-up of sediment.
■Keep sharp tools and abrasive materials away from flexible pipe.
■WHEN INSTALLING THE WC CONNECTOR TO THE WC PANSPIGOT WE RECOMMEND THAT THE INLET SOCKET OF THECONNECTOR BE LUBRICATED WITH CLEAN WATER THENPUSHED FIRMLY ON TO THE SPIGOT OF THE WC PAN. THE SOILPIPE TO BE CONNECTED TO THE CONNECTOR OUTLETSHOULD BE CUT SQUARE AND FREE OF ANY DEBRIS. THEFINNED SEAL SPIGOT OUTLET OF THE WC CONNECTOR MAY BELUBRICATED WITH SILICONE GREASE TO AID INSTALLATIONINTO THE INTERNAL DIAMETER OF THE SOIL PIPE.
■Do not over tighten the jubilee clip.
■Power tools must not be used to tighten the jubilee clip.
■Do not over extend or pull over the recommended length.
■Installations requiring an extended straight length shouldbe supported.
■Ensure all joints are secure before final fix of the WC pan.
■Do not attempt to clear blockages with the use of drain rods.
Effective length
Effective length
Effective length
Effective length
Effective length
Effe
ctiv
e le
ngth
Effective length
Effective length
Effective length
Eff
ectiv
e le
ngth
22.5
mm
26m
m45
mm
WC-CON8F18-BTW
170mm - 250mm*
Code:
WC-CON8F-BTW
230mm - 480mm*
Code:
WC-CON8F18-S-BTW
170mm - 250mm*
Code:
WC-CON8F-S-BTW
230mm - 480mm*
Code:
Effective length
Effective length
* EFFECTIVE LENGTHMIN/MAX
STRAIGHT EXTENSION
CUT TO LENGTH REQUIRED
WC-CON-EXT Code:
Flexible WC Connectors• All inlet seals will fit 97-107mm diameter
pan spigot.• WC-F18R : WC-F23R : WC-F26R : WC-F23RV :
WC-F26RV : WC-CON8F and WC-CON8FV fitinside 4"/110mm diameter pipe.
• WC-F18S : WC-F23S : WC-F26S : WC-F23SV andWC-F26SV fit inside 31/2"/90mm diameter pipe.
• Connectors with a plain end have an outside diameter of 110mm.
• All Connectors with 11/4" Universal Bossinclude Blank Cap with 11/2" BSP Thread.
• Installations requiring an extended straightlength should be supported firmly to preventany sagging.
• Do not attempt to clear blockages with the use of drain rods.
• WHEN INSTALLING THE WC CONNECTOR TO THEWC PAN SPIGOT WE RECOMMEND THAT THE INLETSOCKET OF THE CONNECTOR BE LUBRICATED WITHCLEAN WATER THEN PUSHED FIRMLY ON TO THESPIGOT OF THE WC PAN. THE SOIL PIPE TO BECONNECTED TO THE CONNECTOR OUTLET SHOULDBE CUT SQUARE AND FREE OF ANY DEBRIS. THEFINNED SEAL SPIGOT OUTLET OF THE WCCONNECTOR MAY BE LUBRICATED WITH SILICONEGREASE TO AID ISTALLATION INTO THE INTERNALDIAMETER OF THE SOIL PIPE.
• Do not over extend or pull flex off inletand outlet locations. Extend flex by pulling fromthe middle of the flex and not from the fixture locations.
86mm
73055 ConMcalpine RED July 2016 FRONT 24/06/2016 09:21 Page 1
Rigid, Flexibleand MACFIT
WC ConnectorsFIXING INSTRUCTIONS& DIMENSIONAL LEAFLET
McALPINE & CO. LTD.,Kelvin Avenue, Hillington,
Glasgow G52 4LF.Telephone: 0141-882 3213
Fax: 0141-891 5065Fax: Orders (Sales Office) 0141-883 5697Website: www.mcalpineplumbing.com
© McAlpine & Co. Ltd. July 2016 L-WC-CON
WC CONNECTOR WALL FLANGES
ANTI CROSS-FLOW ANDRODENT BARRIER VALVE
WC17-114 114mmCode:
WC17-110 110mmCode:
WC17-90 90mmCode:
ARB-1Code:
TO
FIT
PIP
E
170m
m
40mm
WC-F21R
140mm - 280mm*
Code:
FLEXIBLE WC CONNECTORS FOR BACK TO WALL WC PANS
TO FIT OVERPIPE SIZE
WC-F21S
140mm - 280mm*
Code:
WC-F26R170mm - 410mm Code:
WC-F23R140mm - 290mm Code:
WC-F18R100mm - 160mm
EFFECTIVE LENGTHMIN/MAX
EFFECTIVE LENGTHMIN/MAX
Code:
WC-F26S170mm - 410mm Code:
WC-F23S140mm - 290mm Code:
WC-F18S100mm - 160mm Code:
WC-F26P160mm - 380mm Code:
WC-F23P130mm - 260mm Code:
WC-CON8F18190mm - 270mm Code:
WC-CON8F220mm - 400mm Code:
STANDARD CONNECTORS
WC-F26RV180mm - 380mm Code:
WC-F23RV150mm - 280mm Code:
WC-F26SV180mm - 380mm Code:
WC-F23SV150mm - 280mm Code:
WC-F26PV170mm - 380mm Code:
WC-F23PV140mm - 260mm Code:
WC-CON8FV220mm - 400mm Code:
CONNECTORS WITH 11/4"UNIVERSAL BOSS
25mm
25mmEFFECTIVE LENGTH
MIN/MAXEFFECTIVE LENGTH
MIN/MAX
We would recommend the use of a Flexible HoseClip Driver as illustrated to tighten the jubilee clip.(Standard 7mm driver for hose clips as shown).
Please note: When these products are used on excessively misshapen pan outlet spigots, the use of silicone sealant can bean advantage to ensure an air and water tight seal is achieved.FLEXIBLE HOSE CLIP DRIVER
FIXING ADVICE
■ Tested to BS5627: 1984.
■ Tests prove conclusively that there is no build-up of sediment.
■ Keep sharp tools and abrasive materials away from flexible pipe.
■ WHEN INSTALLING THE WC CONNECTOR TO THE WC PANSPIGOT WE RECOMMEND THAT THE INLET SOCKET OF THECONNECTOR BE LUBRICATED WITH CLEAN WATER THENPUSHED FIRMLY ON TO THE SPIGOT OF THE WC PAN. THE SOILPIPE TO BE CONNECTED TO THE CONNECTOR OUTLETSHOULD BE CUT SQUARE AND FREE OF ANY DEBRIS. THEFINNED SEAL SPIGOT OUTLET OF THE WC CONNECTOR MAY BELUBRICATED WITH SILICONE GREASE TO AID INSTALLATIONINTO THE INTERNAL DIAMETER OF THE SOIL PIPE.
■ Do not over tighten the jubilee clip.
■ Power tools must not be used to tighten the jubilee clip.
■ Do not over extend or pull over the recommended length.
■ Installations requiring an extended straight length shouldbe supported.
■ Ensure all joints are secure before final fix of the WC pan.
■ Do not attempt to clear blockages with the use of drain rods.
Effective length
Effective length
Effective length
Effective length
Effective length
Effective length
Effective length
Effective length
Effective length
Effective length
22.5mm
26mm
45mm
WC-CON8F18-BTW
170mm - 250mm*
Code:
WC-CON8F-BTW
230mm - 480mm*
Code:
WC-CON8F18-S-BTW
170mm - 250mm*
Code:
WC-CON8F-S-BTW
230mm - 480mm*
Code:
Effe
ctiv
e le
ngth
Effe
ctiv
e le
ngth
* EFFECTIVE LENGTHMIN/MAX
STRAIGHT EXTENSION
CUT TO LENGTH REQUIRED
WC-CON-EXTCode:
Flexible WC Connectors•All inlet seals will fit 97-107mm diameter
pan spigot.•WC-F18R : WC-F23R : WC-F26R : WC-F23RV :
WC-F26RV : WC-CON8F and WC-CON8FV fitinside 4"/110mm diameter pipe.
•WC-F18S : WC-F23S : WC-F26S : WC-F23SV andWC-F26SV fit inside 31/2"/90mm diameter pipe.
•Connectors with a plain end have an outside diameter of 110mm.
•All Connectors with 11/4" Universal Bossinclude Blank Cap with 11/2" BSP Thread.
•Installations requiring an extended straightlength should be supported firmly to preventany sagging.
•Do not attempt to clear blockages with the use of drain rods.
•WHEN INSTALLING THE WC CONNECTOR TO THEWC PAN SPIGOT WE RECOMMEND THAT THE INLETSOCKET OF THE CONNECTOR BE LUBRICATED WITHCLEAN WATER THEN PUSHED FIRMLY ON TO THESPIGOT OF THE WC PAN. THE SOIL PIPE TO BECONNECTED TO THE CONNECTOR OUTLET SHOULDBE CUT SQUARE AND FREE OF ANY DEBRIS. THEFINNED SEAL SPIGOT OUTLET OF THE WCCONNECTOR MAY BE LUBRICATED WITH SILICONEGREASE TO AID ISTALLATION INTO THE INTERNALDIAMETER OF THE SOIL PIPE.
•Do not over extend or pull flex off inletand outlet locations. Extend flex by pulling fromthe middle of the flex and not from the fixture locations.
86mm
73055 ConMcalpine RED July 2016 FRONT 24/06/2016 09:21 Page 1
10mm Offset ExtensionReducer.Adjustable Length.
Code: WC-EXTD
10mm Offset ExtensionAdjustable Length.
Code: WC-EXTC
Straight ExtensionReducer.Adjustable Length.
Code: WC-EXTB
Straight Extension.Adjustable Length.
Code: WC-EXTA
45° Angle.
Code: WC-CON16
90° Space Saving Bend.Adjustable Length.
Code: WC-CONQP• Tested to BS 5627 : 1984• Inlet seals will fit Pans manufactured to
BS 5503/4 and BS 1213.• Outlet seals will fit inside 4"/110mm
diameter pipe except MAC-EXTB which fitsinside 31/2"/90mm pipe and MAC-EXTCwhich fits inside 3"/75mm pipe.
•
MACFIT(patent pending)
WC ConnectorsManufactured in EVA
Code: MAC-EXTA
Straight.4"/110mm Outlet.
Code: MAC-1
20mm Offset.4"/110mm Outlet.
Code: MAC-4
14º Angle.4"/110mm Outlet.
Code: MAC-7A
90º Bend.4"/110mm Outlet.Non Adjustable.
Code: MAC-8
Code: MAC-8L
90º Bend (Long).4"/110mm Outlet.Non Adjustable.
Code: MAC-EXTB
Code: MAC-EXTC
Linking Connector(Polypropylene).
Code: MACLINK
Straight.31/2"/90mm Outlet.
Code: MAC-3
Straight Extension.4"/110mm Outlet.
Straight Extension.31/2"/90mm Outlet.
Straight Extension.3"/75mm Outlet.
40mm Offset.4"/110mm Outlet.
Code: MAC-4A
Straight.
Code: WC-CON1
Straight. 11/4" UniversalPipe Boss, includingBlanking Cap with 11/2"BSP Thread.
Code: WC-CON1V
Straight.Adjustable Length.
Code: WC-CON2
Straight Reducer.Adjustable Length.
Code: WC-CON2B
Straight.Adjustable Length.
Code: WC-CON3
20mm Offset.
Code: WC-CON4
40mm Offset.
Code: WC-CON4A
40mm Offset.
Code: WC-CON4B
20mm Offset.Adjustable Length.
Code: WC-CON5
24mm Offset Reducer.Adjustable Length.
Code: WC-CON5B
90º Bend. 11/4" UniversalPipe Boss, includingBlanking Cap, with 11/2"BSP Thread.Adjustable Length.
Code: WC-CON8V
90º Bend.Adjustable Length.
Code: WC-CON9
90º Bend. 11/4" UniversalPipe Boss, includingBlanking Cap, with 11/2"BSP Thread.Adjustable Length.
Code: WC-CON9V
90º Space Saving Bend.Adjustable Length.
Code: WC-CONQ
14º Angle Reducer.Adjustable Length.
Code: WC-CON7B
14º Angle.
Code: WC-CON7A
14º Angle.Adjustable Length.
Code: WC-CON7
10mm Offset.Adjustable Length.
Code: WC-CON6
9 0 º B e n d . A d j u s t a b l e L e n g t h .
Code: WC-CON8 Code: WC-CON8E
10mm
240mm
85mm
• Tested to BS5627.• All inlet seals will fit 97-107mm diameter
pan spigot.• All outlet seals will fit inside 4"/110mm
diameter pipe except WC-CON2B,WC-CON5B, WC-CON7B, WC-EXTB andWC-EXTD which fit inside 31/2"/90mmdiameter pipe.
• Connectors with a plain end have anoutside diameter of 110mm.
•
Rigid WC Connectors
WHEN INSTALLING THE WC CONNECTOR TO THE WC PAN SPIGOT WE RECOMMEND THAT THE INLET SOCKET OF THE CONNECTOR BE LUBRICATED WITH CLEAN WATER THEN PUSHED FIRMLY ON TO THE SPIGOT OF THE WC PAN. THE SOIL PIPE TO BE CONNECTED TO THE CONNECTOR OUTLET SHOULD BE CUT SQUARE AND FREE OF ANY DEBRIS. THE FINNED SEAL SPIGOT OUTLET OF THE WC CONNECTOR MAY BE LUBRICATED WITH SILICONE GREASE TO AID ISTALLATION INTO THE INTERNAL DIAMETER OF THE SOIL PIPE.
WHEN INSTALLING THE WC CONNECTOR TO THE WC PAN SPIGOT WE RECOMMEND THAT THE INLET SOCKET OF THE CONNECTOR BE LUBRICATED WITH CLEAN WATER THEN PUSHED FIRMLY ON TO THE SPIGOT OF THE WC PAN. THE SOIL PIPE TO BE CONNECTED TO THE CONNECTOR OUTLET SHOULD BE CUT SQUARE AND FREE OF ANY DEBRIS. THE FINNED SEAL SPIGOT OUTLET OF THE WC CONNECTOR MAY BE LUBRICATED WITH SILICONE GREASE TO AID ISTALLATION INTO THE INTERNAL DIAMETER OF THE SOIL PIPE.
73055 ConMcalpine RED July 2016 BACK 24/06/2016 09:21 Page 1