WATERJET APPLICATIONS...SVI-10000-M 125,000 Jet Edge 150HP 15 45 60 SVI-15000-M 130,000 25XQ 15 45...

2
WATERJET APPLICATIONS Machine Tool Industry Reliable, Versatile, and Adaptable 3 –15 Ton Capacity Closed Loop for Water Savings Today’s industrial manufacturers understand that a waterjet cutting system needs to maintain consistent temperatures to cut through materials that are temperature sensitive. To support the water stream, typically the width of a hair, and at speeds up to 3,000 feet per second, waterjet industrial cutting uses high pressure intensifier pumps that need to be consistently cooled between 50 and 60ºF. Using a recirculating chiller can consistently maintain that temperature and save water and money by not wasting 12 to 15 gallons per minute when using a flow-through system with city water. Product Features • Air-Cooled or Water-Cooled Condenser, Closed Loop Water or Water/Glycol Operations Ambient Temperature Range 50–95ºF • Temperature Stability ± 3ºF Built to UL 1995 (Optional cUL Certification) 18-Month Parts and Labor Warranty • 24/7 Service and Support • Next Day Parts Available (Fluid temperatures and ambients can vary. Consult factory for the effect on capacity. Stated capacity based on 60ºF fluid setpoint and 95ºF ambient.) Base Configuration Digital Controller Hermetic Compressor Brazed Plate Evaporator Manual Fluid Bypass Valve Hot Gas Regulator Discharge Fluid Pressure Gauge Seamless, Plastic, Non-Pressurized Tank Refrigerant and Tank Sight Glasses Cleanable Air Filters Fused Disconnect Vertical Air Discharge Options Outdoor Design Pressure and Flow Pump Upgrades Pressure Relief Bypass Valve Inlet Water Filter Auto-Water Fill to Maintain Water Level Anti-Backflow Kit (Necessary with Overhead Piping) Float Switch to Detect Low Tank Fluids Insulation for Above 28ºF Setpoint Remote Controller Casters (Up to 5 Tons) cUL Certification

Transcript of WATERJET APPLICATIONS...SVI-10000-M 125,000 Jet Edge 150HP 15 45 60 SVI-15000-M 130,000 25XQ 15 45...

  • WATERJET APPLICATIONS Machine Tool Industry

    Reliable, Versatile, and Adaptable 3 –15 Ton Capacity

    Closed Loop for Water SavingsToday’s industrial manufacturers understand that a waterjet cutting system needs to maintain consistent temperatures to cut through materials that are temperature sensitive. To support the water stream, typically the width of a hair, and at speeds up to 3,000 feet per second, waterjet industrial cutting uses high pressure intensifier pumps that need to be consistently cooled between 50 and 60ºF. Using a recirculating chiller can consistently maintain that temperature and save water and money by not wasting 12 to 15 gallons per minute when using a flow-through system with city water.

    Product Features• Air- Cooled or Water-Cooled Condenser, Closed Loop

    • Water or Water/Glycol Operations

    • Ambient Temperature Range 50–95ºF

    • Temperature Stability ± 3ºF

    • Built to UL 1995 (Optional cUL Certification)

    • 18-Month Parts and Labor Warranty

    • 24/7 Service and Support

    • Next Day Parts Available

    (Fluid temperatures and ambients can vary. Consult factory for the effect on capacity. Stated capacity based on 60ºF fluid setpoint and 95ºF ambient.)

    Base ConfigurationDigital Controller

    Hermetic Compressor

    Brazed Plate Evaporator

    Manual Fluid Bypass Valve

    Hot Gas Regulator

    Discharge Fluid Pressure Gauge

    Seamless, Plastic, Non-Pressurized Tank

    Refrigerant and Tank Sight Glasses

    Cleanable Air Filters

    Fused Disconnect

    Vertical Air Discharge

    OptionsOutdoor Design

    Pressure and Flow Pump Upgrades

    Pressure Relief Bypass Valve

    Inlet Water Filter

    Auto-Water Fill to Maintain Water Level

    Anti-Backflow Kit (Necessary with Overhead Piping)

    Float Switch to Detect Low Tank Fluids

    Insulation for Above 28ºF Setpoint

    Remote Controller

    Casters (Up to 5 Tons)

    cUL Certification

  • MO

    DE

    L

    CA

    PAC

    ITY

    PR

    OC

    ES

    S

    CO

    OLI

    NG

    PU

    MP

    S

    TAN

    DA

    RD

    TEM

    PE

    RA

    TUR

    E

    INDOOR BTU/HR PUMP GPM PSI F

    JHI-1000-M 460V 12,000 WSI 15HP 4 50 60

    JHI-2000-M 18,000 IR/KMT 30HP 10 35 60

    JHI-2000-M 18,000 WSI 30HP 10 35 60

    JHI-2000-M 22,000 Jet Edge 30HP 10 35 60

    JHI-2000-M 24,000 IR/KMT 50 10 35 60

    SVI-3000-M 24,500 5X 10 45 60

    SVI-3000-M 24,500 30SA 10 45 60

    SVI-3000-M 24,500 6XS 10 45 60

    SVI-3000-M 24,500 50iS 10 45 60

    SVI-3000-M 27,000 9XS/7XS 10 45 60

    SVI-3000-M 27,000 11XS 10 45 60

    SVI-3000-M 30,000 9XD/7XD 10 45 60

    SVI-3000-M 30,000 11XD 10 45 60

    SVI-3000-M 35,000 7XS/R 10 45 60

    SVI-3000-M 35,000 20XS 10 45 60

    SVI-3000-M 35,000 W MC/IS 50HP 10 45 60

    SVI-3000-M 35,000 50iS 10 45 60

    SVI-3000-M 36,000 BOHLER 48HP 10 45 60

    SVI-3000-M 36,000 WSI 50 10 45 60

    SVI-3000-M 36,000 IR/KMT 60 10 45 60

    SVI-3000-M 36,000 IR/KMT 75 10 45 60

    SVI-3000-M 36,000 25-5X 10 45 60

    SVI-3000-M 36,000 25-6XS 10 45 60

    SVI-3000-M 36,000 40-9XS 10 45 60

    SVI-3000-M 36,000 40-9XD 10 45 60

    SVI-3000-M 36,000 40-11XS 10 45 60

    SVI-3000-M 36,000 50-7XS 10 45 60

    MO

    DE

    L

    CA

    PAC

    ITY

    PR

    OC

    ES

    S

    CO

    OLI

    NG

    PU

    MP

    S

    TAN

    DA

    RD

    TEM

    PE

    RA

    TUR

    E

    INDOOR BTU/HR PUMP GPM PSI F

    SVI-5000-M 40,000 12XT 10 45 60

    SVI-5000-M 40,000 Jet Edge 40HP 10 45 60

    SVI-5000-M 45,000 Hyperjet 50 10 45 60

    SVI-5000-M 60,000 IR/KMT 100 10 45 60

    SVI-5000-M 60,000 50-20XS 10 45 60

    SVI-5000-M 60,000 60-7XD 10 45 60

    SVI-5000-M 60,000 60-11XD 10 45 60

    SVI-5000-M 60,000 100-12XT 10 45 60

    SVI-7500-M 65,000 Jet Edge 75HP 12 45 60

    SVI-7500-M 66,254 IR/KMT 150 12 45 60

    SVI-7500-M 70,000 Hyperjet 94i D 100HP 12 45 60

    SVI-7500-M 70,000 Hyperjet 94i D 87HP 12 45 60

    SVI-7500-M 70,000 Hyperjet 100iD 12 45 60

    SVI-7500-M 70,000 20XD 12 45 60

    SVI-7500-M 70,000 S MC/IS 100HP 12 45 60

    SVI-7500-M 70,000 W MC/IS 100HP 12 45 60

    SVI-7500-M 70,000 7XD 12 45 60

    SVI-7500-M 88,000 WSI 100HP 12 45 60

    SVI-7500-M 89,136 IR/KMT 200 12 45 60

    SVI-10000-M 95,000 Hyperjet 100 12 45 60

    SVI-10000-M 95,000 Jet Edge 100HP 12 45 60

    SVI-10000-M 96,000 BOHLER 96HP 12 45 60

    SVI-10000-M 100,000 25X 15 45 60

    SVI-10000-M 100,000 25XT 15 45 60

    SVI-10000-M 120,000 150-25XT 15 45 60

    SVI-10000-M 125,000 Jet Edge 150HP 15 45 60

    SVI-15000-M 130,000 25XQ 15 45 60

    SVI-15000-M 175,000 Jet Edge 200HP 15 45 60

    Standard indoor units are designed to run on straight water or water/glycol with hot gas regulator.

    GDTS chillers can be configured to cool multiple waterjet applications. Contact GDTS to learn more about a central chiller.

    Glen Dimplex Thermal Solutions 2625 Emerald Drive, Kalamazoo, MI 49001

    (800) 968-5665 dimplexthermal.com | [email protected]

    Rev 1.0

    092019

    WJInd2018