Water Treatment Division Demineralisers Medium Flow. Units available Low Salinity Production (m 3...

13
Water Treatment Division Demineralisers Medium Flow. Units available Low Salinity Productio n (m 3 /day) 4VA0100 2.5 4VA0200 5 4VA0300 10 4VA0400 20 Mod. 4VA0X00: Cancelled Many membranes replaced in guarantee period. Corrosion problems due to high salinity Chlorine remover filter insufficient (chlorine damages the membranes) Few pre-treatments available RO Demineralisers, Medium Flow

Transcript of Water Treatment Division Demineralisers Medium Flow. Units available Low Salinity Production (m 3...

Page 1: Water Treatment Division Demineralisers Medium Flow. Units available Low Salinity Production (m 3 /day) 4VA01002.5 4VA02005 4VA030010 4VA040020 Mod. 4VA0X00:

Water Treatment Division

Demineralisers Medium Flow. Units available

Low Salinity

Production (m3/day)

4VA0100 2.5

4VA0200 5

4VA0300 10

4VA0400 20

Mod. 4VA0X00: Cancelled• Many membranes replaced in guarantee

period.

• Corrosion problems due to high salinity

• Chlorine remover filter insufficient (chlorine damages the membranes)

• Few pre-treatments available

RO Demineralisers, Medium Flow

Page 2: Water Treatment Division Demineralisers Medium Flow. Units available Low Salinity Production (m 3 /day) 4VA01002.5 4VA02005 4VA030010 4VA040020 Mod. 4VA0X00:

Water Treatment Division

Low Salinity

High Salinity

Production (m3/day)

Membranes

4DA1100 4DA2100 4-6 1

4DA1200 4DA2200 8-12 2

4DA1300 4DA2300 14-18 3

4DA1400 4DA2400 20-22 4

Mod. 4DAXX00: Available• Equipments to process water from wells and brackish water,

suitable to treat up to 2.500 mg/l (low salinity) and 9.000 mg/l (high salinity) of TDS, respectively.

• It can be mounted in a small cabinet Mod. 4045500

• Optional production capacity increase with adittional membranes (1-4)

• Options: Chlorine remover filter, silex filter, iron remover filter, organic matter filter. Biocide doser, Bisulfite and water softener for boilers.

Chlorine remover

Filter

Organic Matter Filter

Biocide Doser

Bisulfite Doser

RO Demineralisers Medium

Demineralisers Medium Production Capacity. Units available

Iron remover Filter

Silex-antracite Filter

Page 3: Water Treatment Division Demineralisers Medium Flow. Units available Low Salinity Production (m 3 /day) 4VA01002.5 4VA02005 4VA030010 4VA040020 Mod. 4VA0X00:

Water Treatment Division

Models 4DAXX00. Main Features:

Antiscalant doser instead of a water softener with salt.

Antiscalant automatic mixture preparation.

Backwash with demineralised water instead of feeding water. Advantages due to the use of antiscalant:

Ecological: No brine from the water softner regeneration Logistics and easy use: no need to stack salt bags and simplicity Cheaper: antiscalant is cheaper than salt consumption Expansion of the action capacity: wide espectrum

Balance in the ratio production/surface & reject/surface of the membrane compared with the old existing equipments.

RO Demineralisers Medium

Page 4: Water Treatment Division Demineralisers Medium Flow. Units available Low Salinity Production (m 3 /day) 4VA01002.5 4VA02005 4VA030010 4VA040020 Mod. 4VA0X00:

Water Treatment Division

Models 4DAXX00. Main Features: Quality of components:

• Programmable PLC Siemens S7-200• Centrífugal Pump Grundfos• Metering Pump Prominent• Stainless steel frame quality AISI-304• Piping of High salinity range in stainless steel AISI-316• Toray membranes: TMG10 (Low salinity), TM710 (High salinity)

Production can be upgraded just by adding membranes to the existing equipment (no need to buy a full new system).

Suitable cabinet assembly

Wide range of pre-treatments available:

RO Demineralisers Medium

Page 5: Water Treatment Division Demineralisers Medium Flow. Units available Low Salinity Production (m 3 /day) 4VA01002.5 4VA02005 4VA030010 4VA040020 Mod. 4VA0X00:

Water Treatment Division

Just like a car, the models 4DA have two types of alarms to inform us about any possible failure and its seriuosness.

CAR DEMINERALISER

TYPE OF ALARM

EXAMPLE ACTION EXAMPLE ACTION

NOT CRITICAL

Windscreen wiper water

shortage

Amber light: to stop in a few miles

Flow of demineralised

water production, product dosing.

Failure warning, failure record and equipment stop after 10 days.

CRITICALMotor oil

shortage, brake fluid shortage

Red light: immediate

stop

Water shortage, levels, overcurrent.

To stop the equipment

RO Demineralisers Medium

Models 4DAXX00. Example of anomaly

Page 6: Water Treatment Division Demineralisers Medium Flow. Units available Low Salinity Production (m 3 /day) 4VA01002.5 4VA02005 4VA030010 4VA040020 Mod. 4VA0X00:

Water Treatment Division

Buzzer included to alert the customer about

the failures.

• The equipment must recognize the adverse conditions to assure a long operational life.

• The demineralisers are equipments overlooked by the customer (is a non productive equipment) and usually there is not a preventive maintenance of these installations.

• The equipment will stop only if there is an imminent risk to its operating life, avoiding irreversible and expensive damages.

• The customer must be informed of any anomaly (critical or not) without decreasing the business.

RO Demineralisers Medium

Models 4DAXX00. Main Features:

Buzzer Light Alert

Page 7: Water Treatment Division Demineralisers Medium Flow. Units available Low Salinity Production (m 3 /day) 4VA01002.5 4VA02005 4VA030010 4VA040020 Mod. 4VA0X00:

Water Treatment Division

Height 2.000 mm

Length 1.550 mmWidth 480 mm It is possible to be installed in cabinet Ref.

4033500 (size with cabinet: Height 2.100 mm x Width 1.500 mm x Depth 900 mm

Demineraliser. Size.

RO Demineralisers Medium

Page 8: Water Treatment Division Demineralisers Medium Flow. Units available Low Salinity Production (m 3 /day) 4VA01002.5 4VA02005 4VA030010 4VA040020 Mod. 4VA0X00:

Water Treatment Division

Demineraliser. Available Configuration

Assembly in Plant Configuration

RO Demineralisers Medium

Page 9: Water Treatment Division Demineralisers Medium Flow. Units available Low Salinity Production (m 3 /day) 4VA01002.5 4VA02005 4VA030010 4VA040020 Mod. 4VA0X00:

Water Treatment Division

Maintenance of Demineralisers 4DAXXXX

1.- Daily maintenance

To check the level of chemical product.

2.- Every week

To check and to take note of pressures and flows.

3.- Every 3 months

To check the condition of the filters (FS1 & FS2), if necessary they should be changed.

4.- Every 6 months

To clean the small tanks of anti-scalant and backwash water.

RO Demineralisers Medium

Page 10: Water Treatment Division Demineralisers Medium Flow. Units available Low Salinity Production (m 3 /day) 4VA01002.5 4VA02005 4VA030010 4VA040020 Mod. 4VA0X00:

Water Treatment Division

Water softener 2x100 litresSalt Consumption:

– Daily need of water: 21 m3 at 70 ºHF (39,2ºHD).

– Necessary regeneration of the water softener every 9 m3

– Number of regenerations per day: (21m3/day) / (9m3/ regeneration) = 2.3 regenerations /day

– Consumption of salt per litre of resin in every regeneration: 0,2 kg/Litres of resin

– Consumption of salt in every regeneration: 0,2 kg/Litre of resin x 100 Litres of resin = 20 kg of salt per regeneration

– Salt consumption per day: 2.3 regenerations / day x 20 kg of salt/regeneration = 46 kg/day

– Salt consumption in the same period of time (124 days): 46 kg/day x 124 days = 5. 704 kg = 228 sacks of 25 kg

Antiscalant dosageConsumption of antiscalant product:

– Daily need of water: 21 m3 at 70 ºHF (39,2ºHD).

– “High” dosage of product: 5 mg/L = 5 g/m3 – Daily product consumption: 21m3 x 5 g/m3 =

105 g/day = 0.105 kg/day– 1 carafe 10 L = 13 kg– So 1 carafe of 10 litres of antiscalant will

last: 13 kg / 0.105 kg/day = 124 days

Example of calculation of Antiscalant vs Water Softener

RO Demineralisers Medium

Page 11: Water Treatment Division Demineralisers Medium Flow. Units available Low Salinity Production (m 3 /day) 4VA01002.5 4VA02005 4VA030010 4VA040020 Mod. 4VA0X00:

Water Treatment Division

Conclusion: In 124 days of use:

5.704 Kg of salt =

1 bottle of 10 L (13 Kg)

Make yourself your calculations:

Price/kg Salt x 5.700 kg salt = Euros spent on salt versus

PVP 10 L Antiscalant carafe = 189 ,00 Eur

Example of calculation of Antiscalant vs Water Softener

RO Demineralisers Medium

Page 12: Water Treatment Division Demineralisers Medium Flow. Units available Low Salinity Production (m 3 /day) 4VA01002.5 4VA02005 4VA030010 4VA040020 Mod. 4VA0X00:

Water Treatment Division

Difference between antiscalant and water softener.

Antiscalant doser system

+Antiscalant drum

Water softener+

Salt

RO Demineralisers Medium

Page 13: Water Treatment Division Demineralisers Medium Flow. Units available Low Salinity Production (m 3 /day) 4VA01002.5 4VA02005 4VA030010 4VA040020 Mod. 4VA0X00:

Water Treatment Division

RO Demineralisers Medium

Car Wash Equipment

Equipment performance

5m3/day

4DA1100 – Low salinity

4DA2100 – High salinity

Equipment performance

10m3/day

4DA1200 – Low salinity

4DA2200 – High salinity

Equipment performance

15m3/day

4DA1300 – Low salinity

4DA2300 – High salinity

Equipment performance

20m3/day

4DA1400 – Low salinity

4DA2400 – High salinity

M-7

M-9

+ accumulation

tank

= 5 m3

M-15+ accumulation

tank

= 10 m3

M-18+ accumulation

tank

= 15 m3

4TB0100

4TB0400

+ accumulation

tank

= 15 m3 Range:

Low salinity: 0 ppm– 2.500 ppm

High salinity : 2.500 ppm – 9.000 ppm

All R.O. equipments must be installed with a pretreatment stage according to the intake water quality !