Water chiller - Heat pump DYNACIAT power - Breal -...
Transcript of Water chiller - Heat pump DYNACIAT power - Breal -...
NA
10.1
5 A
Water chiller - Heat pump
The green power of comfort
LI
VE
P
UR
EL
Y
•
LI
VE
W
EL
L
•
LI
VE
S
US
TA
IN
AB
LY
DYNACIAT power
Water chiller and water/water heat pump
DYNACIAT power
CIAT technology has achieved excellence!
Sustainable comfort, total adaptability
Proven performance, maximum savings
Targeted applications
Thanks to its compressors which are arranged in parallel on the same refrigeration circuit, Dynaciat Power's capacity adapts itself with ease and efficiency to your specific needs.The self-adjusting CONNECT 2 control system anticipates variations in load and switches on only the number of compressors needed.Dynaciat Power’s energy efficiency is higher throughout the year. The energy savings are visible throughout the life of the system. The comfort of the occupants is unequalled, no matter what the season.
Variations in seasonal heat loads
The European Seasonal Energy Efficiency Ratio (ESEER) allows a better and more accurate assessment of the performance of an air conditioning system in terms of cooling capacity, energy efficiency and environmental friendliness. Dynaciat Power shows its exceptional efficiency yet again with an ESEER above 6, which means +45% compared with traditional R407C generators.
With a cold water outlet temperature range of +18°C to -12°C and hot water production up to +55°C for the heat pump version, Dynaciat Power is able to meet all cooling and heating requirements for the Office, Healthcare, Industry, Administrations and Shopping Centre sectors.
With Dynaciat Power, the best technology has to offer resulting from CIAT's considerable experience in the field of water chillers and heat pumps is combined with the latest innovations to achieve a superior level of performance. More power and more savings for more sustainable comfort!
January February March April May June July August September October November December
100%
90%
80%
70%
60%
50%
40%
30%
20%
10%
Class B
Class C
Class D
Class E
Class F
9.00
8.00
7.00
6.00
5.00
4.00
3.00
350 Puissance frigorifique
Puissance récupérée
Puissance frigorifique
Puissance récupérée
Efficacité énergétique globale
300 400 450 500
avec récupération totale
+150%
1 / Eau glacée = 12°C / 7°C - Air = 35°c - Efficacité énergétique = Pf / Pa
2 / Eau glacée = 12°C / 7°C - Air = 35°c - Eau chaude récupération = 55°C / 60°C Efficacité énergétique = Pf+Pde / Pa
3 / Eau glacée = 12°C / 7°C - Eau chaude récupération = 40°C / 45°C Efficacité énergétique = Pf+Pre / Pa
Récupération totaleRécupération partielle
100 100 130avec récupération partielle
sans récupération
Puissance nominale (kW)
25
Pf (kW)
3,05
3,45
3,85
4,25
4,65
5,05
100 200 300 400 500 600 700 800
Cc (kW)
ENERGY CLASS
EER +30%DYNACIAT POWER
Conventional R407C unit
DYNACIAT POWER
4,25
4,65
5,05
5,45
5,85
6,25
200 300 400 500 600 700 800
Cc (kW)
SEASONAL PERFORMANCE
ESEER +45%
Conventional R407C unit
Class B
Class C
Class D
Class E
Class F
9.00
8.00
7.00
6.00
5.00
4.00
3.00
350 Puissance frigorifique
Puissance récupérée
Puissance frigorifique
Puissance récupérée
Efficacité énergétique globale
300 400 450 500
avec récupération totale
+150%
1 / Eau glacée = 12°C / 7°C - Air = 35°c - Efficacité énergétique = Pf / Pa
2 / Eau glacée = 12°C / 7°C - Air = 35°c - Eau chaude récupération = 55°C / 60°C Efficacité énergétique = Pf+Pde / Pa
3 / Eau glacée = 12°C / 7°C - Eau chaude récupération = 40°C / 45°C Efficacité énergétique = Pf+Pre / Pa
Récupération totaleRécupération partielle
100 100 130avec récupération partielle
sans récupération
Puissance nominale (kW)
25
Pf (kW)
3,05
3,45
3,85
4,25
4,65
5,05
100 200 300 400 500 600 700 800
Cc (kW)
ENERGY CLASS
EER +30%DYNACIAT POWER
Conventional R407C unit
DYNACIAT POWER
4,25
4,65
5,05
5,45
5,85
6,25
200 300 400 500 600 700 800
Cc (kW)
SEASONAL PERFORMANCE
ESEER +45%
Conventional R407C unit
Healthcare IndustriesOffices Hotels ShoppingCentres
A smarter and naturally more sustainable solution
Respecting people and their environment
Compact and quiet technology
Exact consumption
Global intelligence
Easy installation and maintenance
This new range uses R410A ozone-friendly refrigerant, which ensure it meets the most demanding requirements for environmental protection and energy efficiency.
Dynaciat Power is compact and has a slim-design for units up to 200 kW/m2, which enables them to be easily integrated into any mechanical room.3 noise performance levels are available (Standard, Low Noise and Xtra Low Noise) to satisfy the most demanding constraints for any site.
EUROVENT "CLASS B" energy classification for all water chiller and heat pump models.
The CONNECT 2 control system takes into account the specific needs of each facility and manages setpoints remotely for greater comfort and energy savings. It also allows Dynaciat Power to communicate remotely with all types of BMS. The "master-slave" function optimises the management of the 2 machines in parallel.
The integration of dual-circuit brazed plate heat exchangers simplifies the hydraulic connections during installation. The maintenance operations are made easier by wide, removable panels that give quick access to the components.
Noise reduction, consumption, energy optimisation, ozone-friendly refrigerant, intelligent controls… All of CIAT's expertise has been combined to develop the latest generation water chiller and heat pump that perfectly meets all needs, to create exemplary living environments.
Classic heat pump
DYNACIAT power
Cc: Cooling capacity Pi: Total electrical power used(1) Eurovent standard conditions - Chilled water = 12°C/7°C - Hot water = 30°C/35°C (2) Eurovent standard conditions Chilled water inlet = 10°C with the same water flow rate as cooling mode
Hot water = 40°C/45°C Preliminary data. Available second half of 2010.
● Supplied as standard ▲ Factory assembled option § Option supplied as a kit
DYNACIAT power series LG-LGP
Model
Cooling mode (1) Heating mode (2) Dimensions (mm)
Weight (kg)Cc kW
Pi kW
Class EUROVENT ESEER Hc
kWPi
kWEUROVENT
Class Length Width Height
700 V 218 46,6 B 6,1 245 57,6 B 2099 996 1869 1055
800V 252 53,3 B 6,17 284 66,3 B 2099 996 1869 1165
900V 289 62 B 6,05 324 76 B 2099 996 1869 1195
1000V 328 70,3 B 5,94 366 85,6 B 2099 996 1869 1315
1100V 357 76,5 B 6 396 93,2 B 2099 996 1869 1365
1200V 386 82,6 B 6,04 428 100,3 B 2099 996 1869 1425
1400 V 437 93 B 6,03 485 112,5 B 2499 996 1900 1706
1600 V 489 105 B 6,03 542 127 B 2499 996 1900 1754
1800V 568 121 B 6,06 630 146 B 3300 996 1900 2500
2100 V 645 138 B 6,05 716 167 B 3300 996 1900 2550
2400 V 723 155 B 6,04 803 187 B 3300 996 1900 2630
DYNACIAT power EQUIPMENT LG-LGP 700V to 1600V 1800V to 2400VSafety switch ● ●Control circuit transformer ● ●Electrical cabinet wire numbers ● ●RS485 communication interface ● ●Water flow controller ● ●Master/slave control of two machines ● ●Phase controller (reversal, loss, asymmetry, over and under voltage) ▲ ▲Electronic expansion valve ▲ ●Low Noise version (compressor casing) ▲ ▲Xtra Low Noise version (compressor casing with noise insulation) ▲ ▲Compressor suction shut-off valves ▲ ▲Low-temperature glycol/water mix (0°C to -12°C) ▲ ▲Soft start ▲ ▲Water filter on evaporator and condenser § §Anti-vibration mounts § §Flexible hydraulic couplings on evaporator and condenser § §Remote control unit (remote control console) § §Relay board with dry contacts § §MULTICONNECT multi-unit management § §LonWorks gateway § §ETHERNET gateway § §
récuperateur
G R O U P E
G R O U P E
G R O U P
R E S I D E N T I A L
B.P. 14 - 01350 Culoz - [email protected] - www.ciat.com
Tel: +33 (0)4 79 42 42 42
A range on the cutting edge of innovation
DYNACIAT power