Washington Energy Star and Built Green Homes Measure Update New Measure Proposal August 12th, 2014...

13
Washington Energy Star and Built Green Homes Measure Update New Measure Proposal August 12th, 2014 1

Transcript of Washington Energy Star and Built Green Homes Measure Update New Measure Proposal August 12th, 2014...

Page 1: Washington Energy Star and Built Green Homes Measure Update New Measure Proposal August 12th, 2014 1.

1

Washington Energy Star and Built Green Homes Measure

UpdateNew Measure Proposal

August 12th, 2014

Page 2: Washington Energy Star and Built Green Homes Measure Update New Measure Proposal August 12th, 2014 1.

2

Measure background

• Measure Name: Energy Star Homes and WA Built Green

Homes• Measure Type: UES• Measure Category: Proven• Measure Sector: Residential• Sunset Date: August, 2017 • Reason for Update: Change in State Code and

Energy Star Standard

Page 3: Washington Energy Star and Built Green Homes Measure Update New Measure Proposal August 12th, 2014 1.

3

Staff Highlighted Areas

• Cost of infiltration reduction. Should these differ from infiltration reduction on existing homes?• Assumption $ 250 / 0.1 ACHn

Page 4: Washington Energy Star and Built Green Homes Measure Update New Measure Proposal August 12th, 2014 1.

4

Specs Development Background• WA 2012 residential code allows a builder to choose one of

many paths• RTF staff worked with WA department of Commerce, NW Energy

Star and Ecotope Consulting to define typical code compliance paths

• RTF Subcommittee formed to help draft Energy Star and Built Green home specs for WA• Built Green 3 or 4 star will use same specs as Energy Star

• These specs provide a Reference Home that may be built to prescriptively or used as an energy use modeling target. Builders to use NW REMRate as a Energy Star compliance tool for RTF approved trade-offs.

Page 5: Washington Energy Star and Built Green Homes Measure Update New Measure Proposal August 12th, 2014 1.

5

Measure Summary: Gas Heated Homes gfac_3a_2a_5a

(40%)gfac_4_5a (40%) gfac_5b (20%)

Above Grade WallsR 21/ R 21+5 for

hz3R 21/ R 21+5 for

hz3R 21/ R 21+5

for hz3R 21 adv. / R 21+5 for hz3

Above Grade Floors R 30 R 30 R 30 R-38

CeilingsR 49 R 49 R 49

R-49 + 21 heel (R 49 adv.)

Glazing U Value 0.3 0.3 0.3 0.28

Infiltration 4 ACH 50 5 ACH 50 PA 5 ACH 50 PA 3 ACH

Heating System 95% AFUE 80% AFUE78 % AFUE

(Federeal Std)95% AFUE

Ventilation Fan 0.35 W/ CFM0.03942 * CFA + 29.565 (Nbr + 1)

0.03942 * CFA + 29.565 (Nbr +

1)0.35 W/ CFM

Water Heater 0.62 EF 0.62 EF 0.82 EF 0.62 EF

Water Fixtures Low Flow Low Flow NA Low Flow

Duct Location - Ducts Inside - Ducts Inside

Lighting 75% efficient 75% efficient 75% efficient 90% efficient

Code OptionEnergy StarBuilt Green

Page 6: Washington Energy Star and Built Green Homes Measure Update New Measure Proposal August 12th, 2014 1.

6

Measure Summary: Electric Homes

Above Grade WallsR 21/ R 21+5 for z6

R 21 adv. / R 21+5 for hz3

Above Grade Floors R 30 R-38

Ceilings R 49R-49 + 21 heel (R

49 adv.)

Glazing U Value 0.3 U Value 0.28

Infiltration 5 ACH 50 PA 3 ACH

Heating System 8.5 HSPF 9 HSPF

Ventilation Fan0.03942 * CFA + 29.565 (Nbr + 1)

0.35 W/ CFM, High Efficacy

Water Heater 0.93 EF 0.93 EF

Water Fixtures Low Flow Low Flow

Duct Location - Ducts Inside

Lighting 75% efficient 90% efficient

Code Option: hp85_3b_5a

Energy StarBuilt Green

Page 7: Washington Energy Star and Built Green Homes Measure Update New Measure Proposal August 12th, 2014 1.

7

Energy Savings Calculations• Simulations conducted in SEEM 96

• RTF approved new construction heating calibration applied

• Staff proposed cooling calibration applied

Page 8: Washington Energy Star and Built Green Homes Measure Update New Measure Proposal August 12th, 2014 1.

8

Incremental Cost

• Incremental cost derived from the following sources:• Standard Information Workbook• 6th Power Plan Appendix• Existing RTF workbooks• Energy Trust Resource Assessment

• Cost of infiltration reduction. Should these differ from infiltration reduction on existing homes?• Assumption $ 250 / 0.1 ACHn

Page 9: Washington Energy Star and Built Green Homes Measure Update New Measure Proposal August 12th, 2014 1.

9

Estimated Useful Life

• EUL of new construction measure is set at 45 years

• Measures with EUL < 45 years have recurring cost at EUL

• Source for EUL:• Existing measure workbooks• DEER• EUL consistent with new construction measures in other

states

Page 10: Washington Energy Star and Built Green Homes Measure Update New Measure Proposal August 12th, 2014 1.

10

Energy Savings Comparison

Note: Existing kWh are an average of all Existing Energy Star New Construction measures. There were three different paths to Energy Star: Envelope, Equipment and Ducts Inside path.

-

500

1,000

1,500

2,000

2,500

3,000

3,500

4,000

HZ1

_CZ1

HZ1

_CZ2

HZ1

_CZ3

HZ2

_CZ1

HZ2

_CZ2

HZ2

_CZ3

HZ3

_CZ1

HZ3

_CZ2

HZ3

_CZ3

HZ1

_CZ1

HZ1

_CZ2

HZ1

_CZ3

HZ2

_CZ1

HZ2

_CZ2

HZ2

_CZ3

HZ3

_CZ1

HZ3

_CZ2

HZ3

_CZ3

Gas Furnace With CAC Heat Pump

Proposed kWh Existing kWh

Page 11: Washington Energy Star and Built Green Homes Measure Update New Measure Proposal August 12th, 2014 1.

11

Incremental Cost Comparison

Note: Existing Cost are an average of all Existing Energy Star New Construction measures. There were three different paths to Energy Star: Envelope, Equipment and Ducts Inside path.

-

500

1,000

1,500

2,000

2,500

3,000

3,500

4,000H

Z1_C

Z1

HZ1

_CZ2

HZ1

_CZ3

HZ2

_CZ1

HZ2

_CZ2

HZ2

_CZ3

HZ3

_CZ1

HZ3

_CZ2

HZ3

_CZ3

HZ1

_CZ1

HZ1

_CZ2

HZ1

_CZ3

HZ2

_CZ1

HZ2

_CZ2

HZ2

_CZ3

HZ3

_CZ1

HZ3

_CZ2

HZ3

_CZ3

Gas Furnace With CAC Heat Pump

Proposed Cost ($) Existing Cost ($)

Page 12: Washington Energy Star and Built Green Homes Measure Update New Measure Proposal August 12th, 2014 1.

12

Cost Effectiveness Comparison

Note: Existing TRC are an average of all Existing Energy Star New Construction measures. There were three different paths to Energy Star: Envelope, Equipment and Ducts Inside path.

-

0.2

0.4

0.6

0.8

1.0

1.2

1.4

1.6

HZ1

_CZ1

HZ1

_CZ2

HZ1

_CZ3

HZ2

_CZ1

HZ2

_CZ2

HZ2

_CZ3

HZ3

_CZ1

HZ3

_CZ2

HZ3

_CZ3

HZ1

_CZ1

HZ1

_CZ2

HZ1

_CZ3

HZ2

_CZ1

HZ2

_CZ2

HZ2

_CZ3

HZ3

_CZ1

HZ3

_CZ2

HZ3

_CZ3

Gas Furnace With CAC Heat Pump

Proposed TRC Existing TRC

Page 13: Washington Energy Star and Built Green Homes Measure Update New Measure Proposal August 12th, 2014 1.

13

RTF Proposed Motion:

“I _________ move that the RTF:

• Adopt the WA Energy Star and Built Green measures and set the sunset date to August 2017