WAS Pumps XFP100E CB1 50HZ.pdf

6
Letterkenny - WAS Pumps at max head (16.67 l/s @ 14.92m) XFP100E CB1 50HZ ABS reserves the right to change any data and dimensions without prior notice and can not be held responsible for the use of information contained in this software. ABSEL PRO 1.7.2 / 2006-12-21 Operating data specification Flow 16.2 l/s 16.2 l/s Head 14.9 m 14.9 m Static head 14.4 m 14.4 m Efficiency 55.8 % 55.8 % Shaft power 4.26 kW 4.26 kW NPSH 1.4 m 1.4 m Fluid Water Water Temperature 4 °C 4 °C Nature of system Single head pump Single head pump No. of pumps 1 1 Pump data Type XFP100E CB1 50HZ XFP100E CB1 50HZ Make ABS ABS Series XFP PE1-PE3 XFP PE1-PE3 Impeller Contrabloc Plus impeller, 1 vane Contrabloc Plus impeller, 1 vane N° of vanes 1 1 Impeller size 225 mm 225 mm Free passage 80 mm 80 mm Suction port DN100 DN100 Discharge port DN100 DN100 Motor data Rated voltage 400 V 400 V Frequency 50 Hz 50 Hz Rated power P2 6 kW 6 kW Nominal speed 1470 rpm 1470 rpm Number of poles 4 4 Efficiency 89.8 % 89.8 % Power factor 0.71 0.71 Rated current 13.6 A 13.6 A Starting current 88.3 A 88.3 A Rated torque 39 Nm 39 Nm Starting torque 81.8 Nm 81.8 Nm Degree of protection IP68 IP68 Insulation class H H ISO 9906 Gr 2 Testnorm 2011-06-29 0 5 10 15 20 25 30 35 40 45 50 Q [l/s] 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 H [m] 3 4 5 6 7 P2 [kW] 10 20 30 40 50 60 70 PE60/4-E-50HZ 69.5% Hydr.eff. 3 3 3 Hydraulic efficiency 1

Transcript of WAS Pumps XFP100E CB1 50HZ.pdf

Page 1: WAS Pumps XFP100E CB1 50HZ.pdf

Letterkenny - WAS Pumps at max head (16.67 l/s @ 14.92m)

XFP100E CB1 50HZ

ABS reserves the right to change any data and dimensions without prior notice and can not be held responsible for the use of information contained in this software.

ABSEL PRO 1.7.2 / 2006-12-21

Operating data specification Flow 16.2 l/s16.2 l/s Head 14.9 m14.9 mStatic head 14.4 m14.4 m Efficiency 55.8 %55.8 %Shaft power 4.26 kW4.26 kW NPSH 1.4 m1.4 mFluid Water Water Temperature 4 °C4 °CNature of system Single head pump Single head pump No. of pumps 1 1

Pump data Type XFP100E CB1 50HZ XFP100E CB1 50HZ Make ABS ABS Series XFP PE1-PE3 XFP PE1-PE3 Impeller Contrabloc Plus impeller, 1 vane Contrabloc Plus impeller, 1 vane N° of vanes 1 1 Impeller size 225 mm225 mmFree passage 80 mm80 mm Suction port DN100 DN100 Discharge port DN100 DN100

Motor data Rated voltage 400 V400 V Frequency 50 Hz50 HzRated power P2 6 kW6 kW Nominal speed 1470 rpm1470 rpmNumber of poles 4 4 Efficiency 89.8 %89.8 %Power factor 0.71 0.71 Rated current 13.6 A13.6 AStarting current 88.3 A 88.3 A Rated torque 39 Nm 39 Nm Starting torque 81.8 Nm 81.8 Nm Degree of protection IP68 IP68 Insulation class H H

ISO 9906 Gr 2

Testnorm

2011-06-29 0 5 10 15 20 25 30 35 40 45 50 Q [l/s]

123456789

101112131415161718192021

H [m]

3

4

5

6

7

P2 [kW]

10203040506070

PE60/4-E-50HZ

69.5%Hydr.eff.

3

3

3

Hydraulic efficiency

1

Page 2: WAS Pumps XFP100E CB1 50HZ.pdf

0 4 8 12 16 20 24 28 32 36 40 44 48 52 Q [l/s]

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

H [m]

3

4

5

6

7

P2 [kW]

10

20

30

40

50

60

70

PE60/4-E-50HZ

69.5%Hydr.eff.

3

3

3

Hydraulic efficiency

1

Pump performance curves

XFP100E CB1 XFP100E CB1 50HZ

1470 rpm

FrequencyDischargeDN100

Reference curve

Curve number

4.26 kWRated power Hydraulic efficiency

1.4 m55.8 %14.9 m16.2 l/s

1 kg/dm³Density

NPSHHeadFlow

50 Hz

2011-07-19Date

1.57 mm²/sRated speedTestnorm

ISO 9906 Gr 2 Viscosity

80 mmContrabloc Plus impeller, 1 vane 1 225 mm

Letterkenny - WAS Pumps at max head (16.67 l/s @ 14.92m)

ABS reserves the right to change any data and dimensions without prior notice and can not be held responsible for the use of information contained in this software.

ABSEL PRO 1.7.2 / 2006-12-21

2011-06-29 RevisionSolid size ImpellerN° of vanesImpeller size

Page 3: WAS Pumps XFP100E CB1 50HZ.pdf

Letterkenny - WAS Pumps at min head (16.67 l/s @ 14.4m)

XFP100E CB1 50HZ

ABS reserves the right to change any data and dimensions without prior notice and can not be held responsible for the use of information contained in this software.

ABSEL PRO 1.7.2 / 2006-12-21

Operating data specification Flow 17.1 l/s17.1 l/s Head 14.7 m14.7 mStatic head 8.2 m8.2 m Efficiency 57.4 %57.4 %Shaft power 4.32 kW4.32 kW NPSH 1.4 m1.4 mFluid Water Water Temperature 4 °C4 °CNature of system Single head pump Single head pump No. of pumps 1 1

Pump data Type XFP100E CB1 50HZ XFP100E CB1 50HZ Make ABS ABS Series XFP PE1-PE3 XFP PE1-PE3 Impeller Contrabloc Plus impeller, 1 vane Contrabloc Plus impeller, 1 vane N° of vanes 1 1 Impeller size 225 mm225 mmFree passage 80 mm80 mm Suction port DN100 DN100 Discharge port DN100 DN100

Motor data Rated voltage 400 V400 V Frequency 50 Hz50 HzRated power P2 6 kW6 kW Nominal speed 1470 rpm1470 rpmNumber of poles 4 4 Efficiency 89.8 %89.8 %Power factor 0.71 0.71 Rated current 13.6 A13.6 AStarting current 88.3 A 88.3 A Rated torque 39 Nm 39 Nm Starting torque 81.8 Nm 81.8 Nm Degree of protection IP68 IP68 Insulation class H H

ISO 9906 Gr 2

Testnorm

2011-06-29 0 5 10 15 20 25 30 35 40 45 50 Q [l/s]

123456789

101112131415161718192021

H [m]

3

4

5

6

7

P2 [kW]

10203040506070

PE60/4-E-50HZ

69.5%Hydr.eff.

3

3

3

Hydraulic efficiency

1

Page 4: WAS Pumps XFP100E CB1 50HZ.pdf

0 4 8 12 16 20 24 28 32 36 40 44 48 52 Q [l/s]

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

H [m]

3

4

5

6

7

P2 [kW]

10

20

30

40

50

60

70

PE60/4-E-50HZ

69.5%Hydr.eff.

3

3

3

Hydraulic efficiency

1

Pump performance curves

XFP100E CB1 XFP100E CB1 50HZ

1470 rpm

FrequencyDischargeDN100

Reference curve

Curve number

4.32 kWRated power Hydraulic efficiency

1.4 m57.4 %14.7 m17.1 l/s

1 kg/dm³Density

NPSHHeadFlow

50 Hz

2011-07-19Date

1.57 mm²/sRated speedTestnorm

ISO 9906 Gr 2 Viscosity

80 mmContrabloc Plus impeller, 1 vane 1 225 mm

Letterkenny - WAS Pumps at min head (16.67 l/s @ 14.4m)

ABS reserves the right to change any data and dimensions without prior notice and can not be held responsible for the use of information contained in this software.

ABSEL PRO 1.7.2 / 2006-12-21

2011-06-29 RevisionSolid size ImpellerN° of vanesImpeller size

Page 5: WAS Pumps XFP100E CB1 50HZ.pdf

50 HzMotor performance curve

PE60/4-E-50HZ

2011-07-19

Letterkenny - WAS Pumps at max head (16.67 l/s @ 14.92m)

400 V1470 rpm6 kW

Tolerance according to VDE 0530 T1 12.84 for rated power

Moment of inertiaStarting torqueStarting current

Frequency

DateRated voltageNumber of polesNominal speedService factorRated power

88.3 A ABSEL PRO 1.7.2 / 2006-12-21 ABS reserves the right to change any data and dimensions without prior notice and can not be held responsible for the use of

information contained in this software.

0.011 kg m²81.8 Nm

Loading

No load

25 %

50 %

75 %

100 %

125 %

P1 [kW]P2 [kW]

0.43580

1.8541.5

3.4143

5.0384.5

6.6796

8.4727.5

I [A]eff [%]

8.9970

9.21480.92

10.0787.88

11.5389.32

13.5989.83

16.388.53

cosn [rpm]

0.069921500

0.29041492

0.48921484

0.63081476

0.70961468

0.75011460

M [Nm]s [%]

00

9.60.5333

19.31.067

29.111.6

39.032.133

49.052.667

4

20 40 60 80 100 120 P2/P2n [%]0 0

0.1 1.5

0.2 3

0.3 4.5

0.4 6

0.5 7.5

0.6 9

0.7 10.5

0.8 12

0.9 13.5

1 15

1.1 16.5

1.2 18

1.3 19.5

1.4 21

P [kW]

I/In

cos

n/ns

M/Mn

P2

P1

eff

s

Page 6: WAS Pumps XFP100E CB1 50HZ.pdf