WAN ANM2000 Network Management System TL1 Operation Manual

173
  A NM2000 Net w ork Man ag ement System Northbou nd Interf ace (TL1) Operation Manual Version: A Cod e: MN000000542 FiberHome Telecommunication Technologies Co., Ltd. October 2010

Transcript of WAN ANM2000 Network Management System TL1 Operation Manual

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    1/172

    ANM2000 Network ManagementSystem

    Northbound Interface (TL1)

    Operation Manual

    Version: A

    Code: MN000000542

    FiberHome Telecommunication Technologies Co., Ltd.

    October 2010

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    2/172

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    3/172

    Thank you for choosing our products.

    We appreciate your business. Your satisfaction is our

    goal. We will provide you with comprehensive technical

    support and after-sales service. Please contact your

    local sales representative, service representative or

    distributor for any help needed at the contact information

    shown below.

    Fiberhome Telecommunication Technologies Co., Ltd.

    Address: No. 5 Dongxin Rd., Hongshan Dist., Wuhan, China

    Zip code: 430073

    Tel: +86-27-87691549

    Fax: +86-27-87691755

    Website: http://www.fiberhomegroup.com

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    4/172

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    5/172

    Legal Notice

    are trademarks of FiberHome Telecommunication Technologies Co., Ltd.(Hereinafter referred to as FiberHome)

    All brand names and produc t names used in th is document are used for

    identification purposes only and are trademarks or registered trademarks

    of their respective holders.

    Al l r ights reserved

    No part of this document (including the electronic version) may be

    reproduced or transmitted in any form or by any means without prior

    written permission from FiberHome.

    Information in this document is subject to change without notice.

    TM

    TMTM

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    6/172

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    7/172

    I

    Preface

    As a commonly used access network management protocol, TL1 (TransactionLanguage 1) has been widely used on the FiberHome access platforms. Thismanual introduces the application range and operation methods of the TL1interface on the FiberHome EPON equipment.

    Relevant Manuals

    Manual Description

    e-Fim ANM2000Broadband AccessNetwork ManagementSystemInstallation Manual(Based on Windows)

    Describes the installation methods of the ANM2000.

    e-Fim ANM2000Broadband AccessNetwork ManagementSystemOperation Manual(Based on Windows)

    Describes the ANM2000 common operations and maintenancemethods for the purpose of helping users know the ANM2000further and operate it well.

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    8/172

    II

    Version and Usage

    Version Instruction

    A The initial version.

    Intended Readers

    This manual is intended for the following readers:

    Planning and designing engineers

    Commissioning engineers

    Operation and maintenance engineers

    To utilize this manual, these prerequisite skills are necessary:

    Data communication technologies

    Access network technologies

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    9/172

    III

    Conventions

    Terminology Conventions

    Terminology Meaning

    ANM2000FiberHome e-Fim ANM2000 Broadband Access NetworkManagement System

    Symbol Conventions

    Symbol Refer to Meaning

    Note Important features or operation guide.

    CautionPossible injury to persons or systems, or cause trafficinterruption or loss.

    Warning May cause severe bodily injuries.

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    10/172

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    11/172

    V

    Operation Safety Rules

    Network management computer should be placed away fromdirect sunlight, electromagnetic interference, heat source,humidity and dust, and with at least 8 cm distance from otherobjects in order to keep good ventilation.

    Use UPS power supply to avoid loss of network managementdata caused by accidental power failure.

    To shut down the network management computer, first exit theoperating system normally and then shut off the power supply.

    The computer crust, UPS power supply and switch (or hub)should be connected to protection earth ground.

    Do not visit Internet via the network management computer withthe ANM2000. Otherwise, it may increase data flow in the net

    card and hence affects normal network management datatransmission or results in other accidents.

    No access to Internet !

    S/OS

    Figure 1 No access to Interne

    To exit the ANM2000 normally does not make equipment out ofcontrol of the network management system.

    Use of unidentified memory devices should be prohibited so asto avoid computer virus.

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    12/172

    VI

    Do not delete any file in the network management systemrandomly or copy any irrelevant file into the networkmanagement computer.

    Do not perform service configuration or expansion in servicerush hours via network management system.

    Network management computer cannot be used for purposesother than network management. Do not modify networkmanagement computers protocol setting, computer name or

    LAN setting randomly. Otherwise, it may result in abnormaloperation of network management system.

    Figure 2 Not permitted to modify protocol setting randomly (1)

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    13/172

    VII

    Figure 3 Not permitted to modify protocol setting randomly (2)

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    14/172

    VIII

    Figure 4 Not permitted to modify computer name randomly

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    15/172

    IX

    Figure 5 Not permitted to modify LAN setting randomly

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    16/172

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    17/172

    Contents

    Preface .................................................................................................................... I

    Relevant Manuals .............................................................................. I

    Version and Usage ............................................................................ II

    Intended Readers ............................................................................. II

    Conventions ..................................................................................... III

    Operation Safety Rules .......................................................................................... V

    1

    Overview ...................................................................................................... 1-1

    1.1 Service Provisioning Interface ........................................................ 1-2

    1.2

    Integrated Test Interface ................................................................ 1-4

    1.3

    Integrated Alarm Interface .............................................................. 1-6

    1.4

    Resource Query Interface .............................................................. 1-8

    2

    Interface Format ........................................................................................... 2-1

    2.1 Format Overview ............................................................................ 2-2

    2.2 Input Command Message Format .................................................. 2-3

    2.3 Acknowledgement Message .......................................................... 2-4

    2.4

    Response Message Format ........................................................... 2-5

    2.5

    Definition of Returned Error Codes ................................................ 2-7

    3 TL1 Commands ............................................................................................ 3-1

    3.1

    Session Control .............................................................................. 3-2

    3.1.1

    Logging in PON EMS (LOGIN) ........................................ 3-2

    3.1.2

    Logging out PON EMS (LOGOUT) .................................. 3-3

    3.1.3 Handshaking Command (SHAKEHAND) ......................... 3-4

    3.2 Integrated Test Interface ................................................................ 3-6

    3.2.1

    PON Service .................................................................. 3-27

    3.2.2

    Voice Service ................................................................. 3-47

    3.2.3 LAN Service ................................................................... 3-66

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    18/172

    ANM2000 Network Management System Northbound Interface (TL1) Operation Manual

    1-2 Version: A

    3.2.4 IPTV Service .................................................................. 3-71

    3.2.5

    Alarms ........................................................................... 3-73

    3.2.6

    VLAN Function............................................................... 3-73

    3.3

    Integrated Alarm Interface ............................................................ 3-76

    3.3.1 Subscribing to Alarms (SUBSCRIBE) ............................ 3-76

    3.3.2 Enabling the Alarm Filtering Function

    (ACT-ALARM-FILTER) .................................................. 3-77

    3.3.3

    Disabling the Alarm Filtering Function

    (DACT-ALARM-FILTER) ................................................ 3-78

    3.3.4

    Modifying the Alarm Filtering Configuration

    (CHG-ALARM-FILTER).................................................. 3-79

    3.3.5 Querying the Current Alarm Filtering Configuration

    (LST-ALARM-FILTER) ................................................... 3-81

    3.3.6 Obtaining Alarms (LST-ALARM) .................................... 3-82

    3.3.7

    Acknowledging an Alarm (ACK-ALARM) ....................... 3-85

    3.3.8

    Cancelling an Alarm Acknowledgement (UNACK-ALARM)

    3-86

    3.3.9 Clearing an Alarm (CLR-ALARM) .................................. 3-87

    3.4 Resource Query Interface ............................................................ 3-89

    3.4.1 Querying the OLT Equipment Information ...................... 3-89

    3.4.2

    Querying the ONU Equipment Information .................... 3-91

    3.4.3

    Querying the Subrack Information ................................. 3-94

    3.4.4

    Querying the Card Information....................................... 3-97

    3.4.5

    Querying the Media Gateway Information ................... 3-101

    3.4.6 Querying the Voice Port Information ............................ 3-103

    3.4.7 Querying the Multicast Service Information ................. 3-105

    3.4.8 Querying the DSL Port InformationErro! Indicador no

    definido.

    3.4.9

    Querying the LAN Port Information .............................. 3-107

    3.4.10

    Querying the Port VLAN Information ............................ 3-111

    3.4.11 Subscribing to the Resource Change Notification........ 3-113

    3.4.12 Unsubscribing to the Resource Change Notification.... 3-114

    3.4.13 Querying the Resource Change Notification ................ 3-116

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    19/172

    1 Overview

    Version: A 1-3

    3.4.14 Reporting the Resource Change Notification ............... 3-118

    3.4.15

    Exporting the Entire Network Resource Information .... 3-120

    3.4.16

    Querying the Resource Change Notification ................ 3-121

    Appendix A The List of Alarms ............................................................................. 1

    Appendix B The List of Parameters ..................................................................... 1

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    20/172

    ANM2000 Network Management System Northbound Interface (TL1) Operation Manual

    1-4 Version: A

    Figures

    Figure 1-1 The overall architecture of the PON IT support system ................... 1-2

    Figure 1-2 The overall architecture of the PON integrated test system............. 1-4

    Figure 1-3 The overall architecture of the PON integrated alarm system ......... 1-6

    Figure 1-4 The overall architecture of the PON resource query system ........... 1-9

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    21/172

    Version: A 1-1

    1 Overview

    This chapter introduces four types of northbound interfaces of the ANM2000, and

    includes the following sections.

    Service provisioning interface

    Integrated test interface

    Integrated alarm interface

    Resource query interface

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    22/172

    ANM2000 Network Management System Northbound Interface (TL1) Operation Manual

    1-2 Version: A

    1.1 Service Provisioning Interface

    The automatic activation system receives the FTTx service activation workorder

    from the upper level service provisioning system, splits the workorder, and then

    maps the sub-task into the detailed NE configuration commands. By accessing the

    PON EMS service provisioning interface and relevant FTTx product platforms /

    NEs (such as the AAA authentication system, the softswitch, the SHLR, the IPTV

    management platform, etc.), the system delivers various NE configurationcommands, so as to implement the automatic activation of the FTTx service.

    The overall architecture of the PON service provisioning system is shown in the

    following figure:

    Service guarantee system

    CRM system

    Resource

    management

    system

    Service

    provision

    system

    Automaticactivation

    system

    PON

    EMS

    Service guarantee

    system (module)

    Construction

    scheduling

    system

    (module)

    Integrated test

    system

    (module)

    Softswitch

    AAAauthentication

    system

    Integrated

    alarm

    system

    Client

    HGU

    Customer service

    system

    Optical

    distributionnetwork

    integrated

    measurement

    system

    Client

    Fault

    complaint

    Service

    accept

    Accounting

    system

    SHLR

    IPTVmanagement

    platform

    BSS

    domain

    OSS

    domain

    ----I1 interface

    ----I3 in terface

    ----I2 interf ace

    ----I4 interface

    ITMS

    OLT

    MDU / SFU

    ----I5 interfac e

    Figure 1-1 The overall architecture of the PON IT support system

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    23/172

    1 Overview

    Version: A 1-3

    As Figure 1-1 shows, the systems involved with the FTTx service provisioning flow

    include: the CRM system, the billing system, the service provisioning system, the

    automatic activation system, the resource management system, the construction

    scheduling system, the integrated test system, the PON EMS system, the AAA

    authentication system, the softswitch system, the SHLR system, the IPTV

    management platform.

    The related interface is described as follows:

    The I1 interface: the PON EMS northbound interface, providing the service

    automatic activation function.

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    24/172

    ANM2000 Network Management System Northbound Interface (TL1) Operation Manual

    1-4 Version: A

    1.2 Integrated Test Interface

    The integrated test system implements the tests of the following aspects: the

    troubleshooting of the PON, the routine monitor, the provisioning and completion

    test of the PON. It initiates the test of the PON access network, and implements

    the network fault reason diagnosis or network quality active monitor of the

    equipment and the line by accessing the PON EMS integrated test interface or the

    PON integrated measurement system.

    The overall architecture of the PON integrated test system is shown in the

    following figure:

    Service guarantee system

    CRM system

    Resource

    management

    system

    Service

    provision

    system

    Automaticactivation

    system

    PON

    EMS

    Service guarantee

    system (module)

    Construction

    scheduling

    system

    (module)

    Integrated test

    system

    (module)

    Softswitch

    AAA

    authenticationsystem

    Integrated

    alarm

    system

    Client

    HGU

    Customer service

    system

    Optical

    distribution

    network

    integrated

    measurement

    system

    Client

    Fault

    complaint

    Service

    accept

    Accounting

    system

    SHLR

    IPTV

    managementplatform

    BSS

    domain

    OSS

    domain

    ----I1 interface

    ----I3 interface

    ----I2 interface

    ----I4 interface

    ITMS

    OLT

    MDU / SFU

    ----I5 interface

    Figure 1-2 The overall architecture of the PON integrated test system

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    25/172

    1 Overview

    Version: A 1-5

    As Figure 1-2 shows, the systems involved with the FTTx integrated test include:

    the customer service system, the service guarantee system, the resource

    management system, the construction scheduling system, the integrated test

    system, the PON EMS system, the PON integrated test system, etc.

    The related interfaces are described as follows:

    The I3 interface: the PON EMS northbound interface, providing the service fault

    diagnosis and routine monitor functions.

    The I2 interface: the PON EMS alarm report interface, completing the NE

    equipment alarm report functions.

    The I4 interface: the northbound interface of the PON integrated test system, used

    to isolate and test various faults caused by the passive equipment (including the

    optical fiber, the optical cable, the splitter, etc.) in the ODN rapidly and effectively.

    In general, the FTTX integrated test system can perform the following threefunctions: the troubleshooting of the PON, the routine monitor of the PON, and the

    provisioning and completion test of the PON.

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    26/172

    ANM2000 Network Management System Northbound Interface (TL1) Operation Manual

    1-6 Version: A

    1.3 Integrated Alarm Interface

    The northbound interface between the PON EMS and the integrated alarm system

    reports the severe alarms influencing multiple subscribers in a batch manner. The

    PON EMS reports the following alarms via this interface: various major alarms at

    the network level (the MDU and the equipment of higher level), including hardware

    faults alarms (such as the faults of the OLT equipment card and the power supply

    module), severe alarms of the MDU software and hardware, abnormal power-offalarms, trunk fiber breakout alarms, and the MDU environment parameters and

    relevant alarms in the FTTB mode.

    The overall architecture of the PON integrated alarm system is shown in the

    following figure:

    Service guarantee system

    CRM system

    Resource

    management

    system

    Service

    provision

    system

    Automaticactivation

    system

    PON

    EMS

    Service guarantee

    system (module)

    Construction

    scheduling

    system

    (module)

    Integrated test

    system

    (module)

    Softswitch

    AAAauthentication

    system

    Integrated

    alarm

    system

    Client

    HGU

    Customer service

    system

    Optical

    distributionnetwork

    integrated

    measurement

    system

    Client

    Fault

    complaint

    Service

    accept

    Accounting

    system

    SHLR

    IPTV

    management

    platform

    BSS

    domain

    OSS

    domain

    ----I1 interface

    ----I3 interface

    ----I2 interface

    ----I4 interface

    ITMS

    OLT

    MDU / SFU

    ----I5 interface

    Figure 1-3 The overall architecture of the PON integrated alarm system

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    27/172

    1 Overview

    Version: A 1-7

    As part of the service guarantee IT system, the integrated alarm system is the

    convergence center of the monitored alarms and events. It performs the following

    functions:

    Alarm collection function: In PON, the system can collect severe alarms that

    influence multiple subscribers in a batch manner and environment alarms on

    the PON equipment via the alarm northbound interface of the PON EMS; can

    initiate the alarm synchronization with the PON EMS system, so as to

    implement the completeness of alarms.

    Alarm handling function: In PON, the system can compress the PON alarmsaccording to the alarm compression rules configured by the operation and

    maintenance division; can provide the detailed alarm information via the

    association between the alarms and resources information (by analyzing the

    association relationship between the alarms and resources information,

    obtains the association relationship between the alarms and the services /

    subscribers, and obtains the source and result relationships between alarms);

    can deliver the workorder to the service guarantee system automatically

    according to the workorder delivering rules.

    Alarm operation function: In PON, users can confirm alarms, confirm deleting

    alarms, and clear alarms; in addition, users can directly confirm, delete, and

    clear the alarms in the PON EMS via the PON EMS alarm northbound

    interface.

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    28/172

    ANM2000 Network Management System Northbound Interface (TL1) Operation Manual

    1-8 Version: A

    1.4 Resource Query Interface

    The PON EMS northbound interface performs the following resource query

    functions: Exports all resource data in PON, queries the network resource data in

    PON, and reports the changing condition of the network resource; among them,

    exporting all resource data in PON is implemented via the file and the FTP, and

    querying the network resource data in PON and reporting the changing condition

    of the network resource are implemented via the TL1 protocol.

    Users can query the following resource data via the PON EMS northbound

    interface: the PON physical resource data, the service resource data, etc. The

    OSS system can synchronize and check the data via the PON EMS northbound

    interface, so as to keep the consistency between the OSS system data and the

    PON EMS data.

    The overall architecture of the PON resource query system is shown in the

    following figure:

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    29/172

    1 Overview

    Version: A 1-9

    Service guarantee system

    CRM system

    Resource

    management

    system

    Service

    provision

    system

    Automatic

    activationsystem

    PON

    EMS

    Service guarantee

    system (module)

    Construction

    scheduling

    system

    (module)

    Integrated test

    system(module)

    Softswitch

    AAAauthentication

    system

    Integrated

    alarmsystem

    Client

    HGU

    Customer service

    system

    Optical

    distribution

    network

    integrated

    measurement

    system

    Client

    Fault

    complaint

    Service

    accept

    Accounting

    system

    SHLR

    IPTV

    management

    platform

    BSS

    domain

    OSS

    domain

    ----I1 interface

    ----I3 interface

    ----I2 interface

    ----I4 interface

    ITMS

    OLT

    MDU / SFU

    ----I5 interface

    Figure 1-4 The overall architecture of the PON resource query system

    As Figure 1-4 shows, the OSS systems involved with the PON EMS resource

    query include: the service guarantee system, the resource management system,

    etc.

    The related interface is described as follows:

    The I5 interface: the PON EMS northbound interface, providing the resource data

    query and resource changing notification functions.

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    30/172

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    31/172

    Version: A 2-1

    2 Interface Format

    This chapter introduces the command format of the TL1 interface, and includesthe following sections.

    Format overview

    Input command message format

    Acknowledgement message

    Response message format

    Definition of returned error codes

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    32/172

    ANM2000 Network Management System Northbound Interface (TL1) Operation Manual

    2-2 Version: A

    2.1 Format Overview

    Command format

    Refers to the format for a user to input a command. The matching mode toexecute a command includes the following conditions:

    Execute an operational command: All character strings are matched exactly.

    Execute a query command: For an optional parameter whose data type ischaracter string, users can execute the fuzzy query; for a compulsoryparameter whose data type is character string, users should execute theexact matching. If the filtering conditions set by a user cannot identify aunique record, and there are multiple records complying with the filteringconditions, the northbound interface will return all records to the user in a list.

    Response format

    Refers to the format of the information which is returned to users. A correspondingcommand input is required to bring up an expected response.

    Remarks

    For descriptions on symbols used in various formats, please see the followingtable.

    Symbol Description

    < >Encloses a certain identifier symbol. For example, canindicate a random integer.

    [ ] Encloses a certain optional symbol or message entry.

    ' 'Encloses a certain identifier letter. For example, a' indicates theEnglish letter a, instead of a variable symbol.

    ( ) Encloses a group of compulsory symbols or message entries.

    *Refers to the postfix, indicating that the current symbol or symbol groupappears 0 or multiple times.

    +Refers to the postfix, indicating that the current symbol or symbol groupappears once or multiple times.

    ^ Refers to a space.

    cr Refers to a carriage return operation.

    lf Refers to a line feed operation.

    |Is used to separate multiple options, indicating that users can selectonly one option. For example, a|b|c indicates to select a or b or c.

    ::=In a certain syntax rule, separate the left and right parts. For example, ::= (0|1|-|9) indicates that the value of is a certaindigital number from 0 to 9 (including 0 and 9).

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    33/172

    2 Interface Format

    Version: A 2-3

    2.2 Input Command Message Format

    Input command message format

    : : ;: : =[ - [ - ] ]Stagi ng Par ameter Bl ock: : =[ ] : : :

    Remark

    The following table describes various parameters of the command:

    Parameter Remark

    command_code

    Refers to the codes of a command, indicating the operations to beperformed. Commonly this parameter complies with the followingformat:[-[-]]verb: Is a compulsory parameter, indicating the command name.Usually it is a verb or abbreviation describing the operation type.modifier: Is used to modify the input command . A verb can include twooptional modifiers, seperated with -.

    staging_blocks

    Refers to the task identifier block. Commonly this parameter complieswith the following format:[]:::target identifier: It is not needed here.access identifier: Refers to the identity information, used to identify theoperation object of the command.ctag (correlation tag): Refers to the command identifier code, used tomatch the input and output commands. In the response meassage andthe input message, this value should be the same.

    payload_blocks

    Refers to the transferring parameter block, and can be null. Commonlythis parameter complies with the following format:

    , Among them, each parameter block (datablock) has the followingformat: parameter name = parameter value, and two parameter blocksare seperated with ,.

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    34/172

    ANM2000 Network Management System Northbound Interface (TL1) Operation Manual

    2-4 Version: A

    2.3 Acknowledgement Message

    The format of theacknowledgement message is described as follows:

    acknowl edgment_code ct ag)

    Response format of query commands:

    [ ] header : : = ^ - - : : r esponse_i d: : =M r esponse_bl ock: : =( ( ^ ^ ) | ( ^ ) )quot ed l i ne: : = ^ ^

    r esul t : : =( *) ( ( ( ) *) )( *) att r i bs: : =( ( ) *) val ues: : =( ( ) *) t ermi nat or: : =( ; | >)

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    36/172

    ANM2000 Network Management System Northbound Interface (TL1) Operation Manual

    2-6 Version: A

    Remark

    For the remarks in the command response result, please see the following table.

    Parameter Remark

    header

    Refers to the message header, meaning the public parts of allresponse and report messages. It includes the equipment ID (sid),date, and time, and commonly complies with the following format:^^^^--^::sid: abbreviation of the manufacturer name _network mangementserver IP address. For exmple, it can be one of the following items:

    HW_IPZTE_IPFH_IP

    response_id

    Refers to the response ID, and commonly complies with thefollowing format:M^^^Ctag: Refers to the command ID, used to match the input andoutput commands. In the response meassage and the inputmessage, this value should be the same.completion code: Refers to the response completion ID, with itsrange as follows:COMPLD: The command is executed correctly.DELAY: The command execution is delayed.DENY: The command execution fails.PRTL: The command is executed partially.RTRV: Returns the results of the executed tests in the command,and other test items are being performed.

    response_block

    Refers to the contents of the response message.EN: Refers to the error code.ENDESC: Refers to the description of an error.quoted line: Refers to the returned parameters. When the queriedinformation includes too many data, the northbound interface willsend the queried data to the client end in packets.total_blocks indicates the total number of data packets,block_number indicates the serial No. of the current data packet,and block_records indicates how many data entries are in thecurrent data packet.title: Is a character string, meaning the title of the result.attrib: Is a character string, meaning the arribute name.value: Is a character string, meaning the arribute value. If it is notsupported, - will be returned.

    terminator

    Is indicated with > or ;.> indicates that the data sending is not completed, and there is anext packet to be received.

    ; indicates that the data sending is completed. There can be only

    one ; in the returned data.

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    37/172

    2 Interface Format

    Version: A 2-7

    2.5 Definit ion of Returned Error Codes

    EN (Error - Code) Error Type ENDESC (Error -Descript ion)

    IRNE INPUT resource does not exist

    IANE INPUT the alarm does not exist

    IMP INPUT missing parameter

    IIPF INPUT invalid parameter format

    IIPE INPUT input parameter error

    DDNS DEVICE device may not support this operation

    DDOF DEVICE device operation failed

    DDB DEVICE device is busy

    SENS SYSTEM EMS may not support this operation

    SEOF SYSTEM EMS operation failed

    EEEH EXCEPTION EMS exception happens

    TUB TEST user is busy

    TUT TEST user is testing

    TTMB TEST test module is busy

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    38/172

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    39/172

    Version: A 3-1

    3 TL1 Commands

    This chapter introduces the operation methods of various TL1 interfaces, andincludes the following sections.

    Session control

    Service provisioning interface

    Integrated test interface

    Integrated alarm interface

    Resource query interface

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    40/172

    ANM2000 Network Management System Northbound Interface (TL1) Operation Manual

    3-2 Version: A

    3.1 Session Control

    The session control is used to manage the communication between the integratedtest system and the PON EMS, so as to prevent access of illegal users.

    3.1.1 Logging in PON EMS (LOGIN)

    Functions

    After establishing the TCP connection successfully, a user can log in the PONEMS via this command. When logging in successfully, a user can delivernorthbound interface commands to operate the equipment.

    Command format

    LOGI N: : : CTAG: : UN=user - name, PWD=passwor d;

    Response format

    Complies with the response format of operational commands mentioned in Section2.4.

    Input parameter

    Parameter Name Data Type Value Range Remark

    UN OCTET STRING SIZE (20) The username

    PWD OCTET STRING SIZE (16) The password

    Output parameter

    None

    Example

    Command:

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    41/172

    3 TL1 Commands

    Version: A 3-3

    LOGI N: : : CTAG: : UN=1, PWD=1;

    Response:

    FH_133. 5. 35. 238 2010- 05- 26 19: 23: 18M CTAG COMPLDEN=0 ENDESC=No er r or

    Meaning:

    The user has logged in successfully.

    3.1.2 Logging out PON EMS (LOGOUT)

    Functions

    A user logs out the PON EMS.

    Command format

    LOGOUT: : : CTAG: : ;

    Response format

    Complies with the response format of operational commands mentioned in Section2.4.

    Input parameter

    None

    Output parameter

    None

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    42/172

    ANM2000 Network Management System Northbound Interface (TL1) Operation Manual

    3-4 Version: A

    Example

    Command:

    LOGOUT: : : CTAG: : ;

    Response:

    FH_133. 5. 35. 238 2010- 05- 26 19: 23: 23M CTAG COMPLD

    EN=0 ENDESC=No er r or

    Meaning:

    The user has logged out successfully.

    3.1.3 Handshaking Command (SHAKEHAND)

    Functions

    If there are no communications on a certain TCP connection in a 10-minuteinterval, the system will disconnect this TCP connection automatically. To maintainthis connection without any other operation, users can deliver a handshakingcommand.

    Command format

    SHAKEHAND: : : CTAG: : ;

    Response format

    Complies with the response format of operational commands mentioned in Section2.4.

    Input parameter

    None

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    43/172

    3 TL1 Commands

    Version: A 3-5

    Output parameter

    None

    Example

    Command:

    SHAKEHAND: : : CTAG: : ;

    Response:

    FH_133. 5. 35. 238 2010- 05- 26 19: 23: 20M CTAG COMPLDEN=0 ENDESC=No er r or

    Meaning:

    The user has handshaked successfully.

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    44/172

    ANM2000 Network Management System Northbound Interface (TL1) Operation Manual

    3-6 Version: A

    3.2 Service Provisioning Interface

    3.2.1 Act ivating a VoIP Port

    Functions

    This command is used to activate a VoIP port.

    Command format

    ACT- VOI PPORT: : ONUI P=onu- name| [ OLTI D=ol t - name, PONI D=ponport _l ocat i on, ONUI DTYPE=onui d- t ype, ONUI D=onu- i ndex] , ONUPORT=onu- port : CTAG: : ;

    Response format

    Complies with the response format mentioned in Section2.4.

    Input parameter

    ParameterName

    Data Type Value Range Remark

    ONUIPOCTETSTRING

    SIZE (128)The IP address, name, or ID of an ONU withthe management IP address

    OLTIDOCTETSTRING

    SIZE (128) The IP address, name, or ID of an OLT

    PONIDOCTETSTRING

    SIZE (128)cabinet-subrack-slot-PON port No.

    The PON port identity information. A PONport is identified by the cabinet-subrack-slot-PON port No. In the absence ofany of the cabinet, subrack, slot, PON portNo., fill with NA.

    ONUIDTYPEOCTETSTRING

    SIZE (128) The ONU ID TYPE (MAC, LOID)

    ONUID OCTETSTRING

    SIZE (128)

    cabinet-subrack-slot-port No.

    The ONU ID, and its value can be one of the

    following four items: MAC, LOID. It is used touniquely identify an ONU connected with theappointed PON port.

    ONUPORTOCTETSTRING

    A card port is identified by the cabinet-subrack-slot-port No., and in the absence ofany of the cabinet, subrack, slot, PON portNo., fill with NA.

    [g1] Comentrio: GPON

    ,

    ,

    3.2.8,3.2.9,3.2.10,3.2.11.3.2.3.3.2.4

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    45/172

    3 TL1 Commands

    Version: A 3-7

    Example

    Command:

    ACT- VOI PPORT: : OLTI D=133. 5. 35. 235, PONI D=NA- NA- 4- 4, ONUI DTYPE=MAC, ONUI D=54- 5B- 04- B3- 43- A0, ONUPORT=NA- NA- NA- 1: CTAG: : ;

    Response:

    FH_133. 5. 35. 238 2010- 05- 22 18: 00: 37M CTAG COMPLDEN=0 ENDESC=No er r or

    Meaning:

    This command is used to activate the NA-NA-NA-1 VOIP port on the54-5B-04-B3-43-A0 ONU.

    3.2.2 Deactivating a VoIP Port

    Functions

    This command is used to deactivate a VoIP port.

    Command format

    DACT- VOI PPORT: : ONUI P=onu- name| [ OLTI D=ol t - name, PONI D=ponport _l ocat i on,ONUI DTYPE=onui d- t ype, ONUI D=onu- i ndex] , ONUPORT=onu- port : CTAG: : ;

    Response format

    Complies with the response format mentioned in Section2.4.

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    46/172

    ANM2000 Network Management System Northbound Interface (TL1) Operation Manual

    3-8 Version: A

    Parameters

    Parameter Name Data Type Value Range Remark

    ONUIP OCTET STRING SIZE (128)The IP address, name, or IDof an ONU with themanagement IP address

    OLTID OCTET STRING SIZE (128)The IP address, name, or IDof an OLT

    PONID OCTET STRING

    SIZE (128)cabinet-subrack-slot-PONport No.

    The PON port identityinformation. A PON port isidentified by the cabinet-subrack-slot-PON port No.,and in the absence of any ofthe cabinet, subrack, slot,

    PON port No., fill with NA.

    ONUIDTYPE OCTET STRING SIZE (128)The ONU ID TYPE (MAC,LOID)

    ONUID OCTET STRING SIZE (128)

    The ONU ID, and its valuecan be one of the followingfour items: MAC, LOID. It isused to uniquely identify anONU connected with theappointed PON port.

    ONUPORT OCTET STRING

    SIZE (128)cabinet-subrack-slot- portNo.

    A card port is identified bythe cabinet-subrack-slot-port No., andin the absence of any of thecabinet, subrack, slot, PONport No., fill with NA.

    Example

    Command:

    DACT- VOI PPORT: : OLTI D=133. 5. 35. 235, PONI D=NA- NA- 4- 4, ONUI DTYPE=MAC, ONUI D=54-5B- 04- B3- 43- A0, ONUPORT=NA- NA- NA- 1: CTAG: : ;

    Response:

    FH_133. 5. 35. 238 2010- 05- 23 10: 31: 22M CTAG COMPLDEN=0 ENDESC=No er r or

    Meaning:

    This command is used to deactivate the NA-NA-NA-1 VOIP port on the54-5B-04-B3-43-A0 ONU.

    3.2.3 Configuring the Voice Service of a VoIP Port

    Functions

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    47/172

    3 TL1 Commands

    Version: A 3-9

    This command is used to configure the voice service of a VoIP port.

    Command format

    CFG- VOI PSERVI CE: : ONUI P=onu- name| [ OLTI D=ol t - name, PONI D=ponport _l ocat i on, ONUI DTYPE=onui d- t ype, ONUI D=onu- i ndex], ONUPORT=onu-por t : CTAG: : [ PHONENUMBER=phone number, ] PT=prot ocol t ype[ , SLVAN=voi p outervl an] [ , VOI PVLAN=voi p i nnervl an] [ , SCOS=out er - qos] [ , CCOS=i nnerqos] [ , EI D=equi pment - i d] [ TI D=Ter mi nal- I D] [ SI PREGDM=si p r egi st er domai n, SI PUSERNAME=si p- user-name] [ , SI PUSERPWD=si puser password] [ MGCI P1=act i ve baci p] [ , MGCI P2=st andby bac i p] [ , I PMODE=i p mode] [ , I P=i paddr ess, I PMASK=i p- mask, I PGATEWAY=i p- gateway] [ , PPPOEUSER=pppoe- user ,

    PPPOEPWD=pppoe passwor d] ;

    Response format

    Complies with the response format mentioned in Section2.4.

    Parameters

    Parameter Name Data Type Value Range Remark

    ONUIP OCTET STRING SIZE (128)The IP address, name, orID of an ONU with the

    management IP address

    OLTID OCTET STRING SIZE (128)The IP address, name, orID of an OLT

    PONID OCTET STRING

    SIZE (128)cabinet-subrack-slot-PONport No.

    The PON port identityinformation. A PON port isidentified by the cabinet-subrack-slot-PON portNo., and in the absence ofany of the cabinet,subrack, slot, PON portNo., fill with NA..

    ONUIDTYPE OCTET STRING SIZE (128)The ONU ID TYPE (MAC,LOID)

    ONUID OCTET STRING SIZE (128)

    The ONU ID, and its valuecan be one of the followingfour items: MAC, LOID. It isused to uniquely identify an

    ONU connected with theappointed PON port.

    ONUPORT OCTET STRING

    SIZE (128)cabinet-subrack-slot- portNo.

    A card port is identified bythe cabinet-subrack-slot-port No., andin the absence of any ofthe cabinet, subrack, slot,PON port No., fill with NA..

    PHONENUMBER OCTET STRING SIZE (1 to 32) The telephone number

    PT OCTET STRING SIZE (1 to 32)The voice protocol type(H.248, SIP)

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    48/172

    ANM2000 Network Management System Northbound Interface (TL1) Operation Manual

    3-10 Version: A

    Parameter Name Data Type Value Range Remark

    EID OCTET STRING SIZE (1 to 64)The MG gateway domainname in the H.248 protocolconfiguration

    TID OCTET STRING SIZE (1 to 64)The H.248 subscriberterminal ID

    SIPREGDM OCTET STRING SIZE (1 to 32) The SIP register server

    SIPUSERNAME OCTET STRING SIZE (1 to 32)The usernamecorresponding to the SIPsubscriber port

    SIPUSERPWD OCTET STRING SIZE (1 to 32)The passwordcorresponding to the SIPsubscriber port

    SVLAN INTEGER 0 to 4095The voice service outerVLAN

    VOIPVLAN INTEGER 0 to 4095 The voice service innerVLAN

    IPMODE OCTET STRING SIZE (1 to 32)The IP obtaining mode:DHCP, PPPoE, static

    IP OCTET STRING SIZE (1 to 32) The IP address

    IPMASK OCTET STRING SIZE (1 to 32) The IP address mask

    IPGATEWAY OCTET STRING SIZE (1 to 32) The gateway address

    PPPOEUSER OCTET STRING SIZE (1 to 32) The PPPoE username

    PPPOEPWD OCTET STRING SIZE (1 to 32) The PPPoE password

    SCOS INTEGER 0 to 7 The outer service priority

    CCOS INTEGER 0 to 7 The inner service priority

    MGCIP1 OCTET STRING SIZE (32)The active softswitch IPaddress

    MGCIP2 OCTET STRING SIZE (32)The standby softswitch IP

    address

    Example

    Command:

    CFG- VOI PSERVI CE: : OLTI D=133. 5. 35. 235, PONI D=NA-NA-4- 4, ONUI DTYPE=MAC, ONUID=54- 5B- 04- B3- 43- A0, ONUPORT=NA- NA- NA- 1: CTAG: : PHONENUMBER=77777777, PT=H. 248, VOI PVLAN=650, CCOS=0, EI D=ei d, TI D=t i d, I PMODE=STATI C, I P=14. 14. 14. 7, IPMASK=255. 255. 0. 0, I PGATEWAY=14. 14. 14. 1;

    Response:

    FH_133. 5. 35. 238 2010- 05- 23 10: 31: 22M CTAG COMPLDEN=0 ENDESC=No er r or

    This command is used to configure the voice service of the 54-5B-04-B3-43-A0ONU VoIP port on the 133.5.35.235 OLT.

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    49/172

    3 TL1 Commands

    Version: A 3-11

    3.2.4 Deleting the Voice Service of a VoIP Port

    Functions

    This command is used to delete configure the voice service of a VoIP port.

    Command format

    DEL- VOI PSERVI CE: : ONUI P=onu- name| [ OLTI D=ol t - name, PONI D=ponport _l ocat i on

    , ONUI DTYPE=onui d- t ype, ONUI D=onu- i ndex] , ONUPORT=onu- port : CTAG: : ;

    Response format

    Complies with the response format mentioned in Section2.4.

    Parameters

    Parameter Name Data Type Value Range Remark

    ONUIP OCTET STRING SIZE (128)The IP address, name, orID of an ONU with the

    management IP address

    OLTID OCTET STRING SIZE (128)The IP address, name, orID of an OLT

    PONID OCTET STRING

    SIZE (128)cabinet-subrack-slot-PONport No.

    The PON port identityinformation. A PON port isidentified by the cabinet-subrack-slot-PON portNo., and in the absence ofany of the cabinet,subrack, slot, PON portNo., fill with NA..

    ONUIDTYPE OCTET STRING SIZE (128)The ONU ID TYPE (MAC,LOID)

    ONUID OCTET STRING SIZE (128)

    The ONU ID, and its valuecan be one of the followingfour items: MAC, LOID. It isused to uniquely identify an

    ONU connected with theappointed PON port.

    ONUPORT OCTET STRING

    SIZE (128)cabinet-subrack-slot- portNo.

    A card port is identified bythe cabinet-subrack-slot-port No., andin the absence of any ofthe cabinet, subrack, slot,PON port No., fill with NA..

    Example

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    50/172

    ANM2000 Network Management System Northbound Interface (TL1) Operation Manual

    3-12 Version: A

    Command:

    DEL- VOI PSERVI CE: : OLTI D=133. 5. 35. 235, PONI D=NA-NA-4- 4, ONUI DTYPE=MAC, ONUID=54- 5B- 04- B3- 43- A0, ONUPORT=NA-NA-NA-1: CTAG: : ;

    Response:

    FH_133. 5. 35. 238 2010- 05- 23 10: 31: 22M CTAG COMPLDEN=0 ENDESC=No er r or

    This command is used to delete configure the voice service of the

    54-5B-04-B3-43-A0 ONU VoIP port on the 133.5.35.235 OLT.

    3.2.5 Activating a LAN Port

    Functions

    This command is used to activate a LAN port.

    Command format

    ACT- LANPORT: : ONUI P=onu- name| OLTI D=ol t - name[ , PONI D=ponport _l ocat i on,ONUI DTYPE=onui d- t ype, ONUI D=onu- i ndex] , ONUPORT=onu- port : CTAG: : ;

    Response format

    Complies with the response format mentioned in Section2.4.

    Parameters

    ParameterName

    Data Type Value Range Remark

    ONUIP OCTET STRING SIZE (128)The IP address, name, or ID of anONU with the management IPaddress

    OLTID OCTET STRING SIZE (128)The IP address, name, or ID of anOLT

    PONID OCTET STRING

    SIZE (128)cabinet-subrack-slot-PONport No.

    The PON port identity information. APON port is identified by the cabinet-subrack-slot-PON port No., and inthe absence of any of the cabinet,subrack, slot, PON port No., fill withNA..

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    51/172

    3 TL1 Commands

    Version: A 3-13

    ParameterName

    Data Type Value Range Remark

    ONUIDTYPE

    OCTET STRING SIZE (128) The ONU ID TYPE (MAC, LOID)

    ONUID OCTET STRING SIZE (128)

    The ONU ID, and its value can beone of the following four items:MAC, LOID. It is used to uniquelyidentify an ONU connected with theappointed PON port.

    ONUPORT OCTET STRING

    SIZE (128)cabinet-subrack-slot- portNo.

    A card port is identified by thecabinet -subrack-slot-port No., andin the absence of any of the cabinet,subrack, slot, PON port No., fill withNA..

    Example

    Command:

    ACT- LANPORT: : OLTI D=133. 5. 35. 235, PONI D=NA- NA- 4- 4, ONUI DTYPE=MAC, ONUI D=54- 5B- 04- B3- 43- A0, ONUPORT=NA- NA- NA- 1: CTAG: : ;

    Response:

    10. 22. 16. 22 2007- 03- 01 13: 35: 00M CTAG COMPLDEN=0 ENDESC=No er r or

    Meaning:

    This command is used to activate the NA-NA-NA-1 FE VOIP port on the54-5B-04-B3-43-A0 ONU.

    3.2.6 Deactivating a LAN Port

    Functions

    This command is used to deactivate a LAN port.

    Command format

    DACT- LANPORT: : ONUI P=onu- name| OLTI D=ol t - name[ , PONI D=ponport _l ocat i on,ONUI DTYPE=onui d- t ype, ONUI D=onu- i ndex] , ONUPORT=onu- port : CTAG: : ;

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    52/172

    ANM2000 Network Management System Northbound Interface (TL1) Operation Manual

    3-14 Version: A

    Response format

    Complies with the response format mentioned in Section2.4.

    Parameters

    ParameterName

    Data Type Value Range Remark

    ONUIP OCTET STRING SIZE (128)The IP address, name, or ID of anONU with the management IPaddress

    OLTID OCTET STRING SIZE (128) The IP address, name, or ID of anOLT

    PONID OCTET STRING

    SIZE (128)cabinet-subrack-slot-PONport No.

    The PON port identity information. APON port is identified by the cabinet-subrack-slot-PON port No., and inthe absence of any of the cabinet,subrack, slot, PON port No., fill withNA.

    ONUIDTYPE OCTET STRING SIZE (128) The ONU ID TYPE (MAC, LOID)

    ONUID OCTET STRING SIZE (128)

    The ONU ID, and its value can beone of the following four items:MAC, LOID. It is used to uniquelyidentify an ONU connected with theappointed PON port.

    ONUPORT OCTET STRING

    SIZE (128)cabinet

    -subrack-slot- portNo.

    A card port is identified by thecabinet -subrack-slot-port No., andin the absence of any of the cabinet,

    subrack, slot, PON port No., fill withNA.

    Example

    Command:

    DACT- LANPORT: : OLTI D=133. 5. 35. 235, PONI D=NA- NA- 4- 4, ONUI DTYPE=MAC, ONUI D=54- 5B- 04- B3- 43- A0, ONUPORT=NA- NA- NA- 1: CTAG: : ;

    Response:

    10. 22. 16. 22 2007- 03- 01 13: 35: 00M CTAG COMPLD

    EN=0 ENDESC=No er r or

    Meaning:

    This command is used to deactivate the NA-NA-NA-1 FE VOIP port on the54-5B-04-B3-43-A0 ONU.

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    53/172

    3 TL1 Commands

    Version: A 3-15

    3.2.7 Configuring the Bandwidth of a LAN Port

    Functions

    This command is used to configure the bandwidth of a LAN port.

    Command format

    CFG- LANPORT: : ONUI P=onu- name| OLTI D=ol t - name[ , PONI D=ponport _l ocat i on,

    ONUI DTYPE=onui d- t ype, ONUI D=onu- i ndex], ONUPORT=onu-por t : CTAG: : BW=bandwi dt h;

    Response format

    Complies with the response format mentioned in Section2.4.

    Parameters

    ParameterName

    Data Type Value Range Remark

    ONUIP OCTET STRING SIZE (128)

    The IP address, name, or ID of an ONU

    with the management IP addressOLTID OCTET STRING SIZE (128) The IP address, name, or ID of an OLT

    PONID OCTET STRING

    SIZE (128)Cabinet-subrack-slot-PON port No.

    The PON port identity information. APON port is identified by the cabinet-subrack-slot-PON port No., and in theabsence of any of the cabinet, subrack,slot, PON port No., fill with NA.

    ONUIDTYPE OCTET STRING SIZE (128) The ONU ID TYPE (MAC, LOID)

    ONUID OCTET STRING SIZE (128)

    The ONU ID, and its value can be oneof the following four items: MAC, LOID.It is used to uniquely identify an ONUconnected with the appointed PONport.

    ONUPORT OCTET STRING

    SIZE (128)Cabinet-subrack-slot-

    port No.

    A card port is identified by the cabinet-subrack-slot-port No., and in theabsence of any of the cabinet, subrack,

    slot, PON port No., fill with NA.BW OCTET STRING SIZE (128) The bandwidth profile name

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    54/172

    ANM2000 Network Management System Northbound Interface (TL1) Operation Manual

    3-16 Version: A

    Example

    Command:

    CFG- LANPORT: : OLTI D=133. 5. 35. 235, PONI D=NA- NA- 4- 4, ONUI DTYPE=MAC, ONUI D=54- 5B-04- B3-43- A0, ONUPORT=NA- NA- NA- 1: CTAG: : BW=4M;

    Response:

    10. 22. 16. 22 2007- 03- 01 13: 35: 00M CTAG COMPLDEN=0 ENDESC=No er r or

    Meaning:

    This command is used to configure the bandwidth of the NA-NA-NA-1 LAN port ofthe 54-5B-04-B3-43-A0 ONU.

    3.2.8 Adding a LAN Port into a Multicast Group

    Functions

    This command is used to add a LAN port into a multicast group.

    Command format

    ADD- LANI PTVPORT: : ONUI P=onu- name| OLTI D=ol t - name[ , PONI D=ponport _l ocat i on, ONUI DTYPE=onui d- t ype, ONUI D=onu- i ndex], ONUPORT=onu-por t : CTAG: : [ UV=uservl an] [ , MVLAN=mvl an] ;

    Response format

    Complies with the response format mentioned in Section2.4.

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    55/172

    3 TL1 Commands

    Version: A 3-17

    Parameters

    ParameterName

    Data Type Value Range Remark

    ONUIPOCTETSTRING

    SIZE (128)The IP address, name, or ID of anONU with the management IPaddress

    OLTIDOCTETSTRING

    SIZE (128)The IP address, name, or ID of anOLT

    PONIDOCTETSTRING

    SIZE (128)Cabinet-subrack-slot-PONport No.

    The PON port identity information. APON port is identified by the cabinet-subrack-slot-PON port No., and inthe absence of any of the cabinet,subrack, slot, PON port No., fill with

    NA.ONUIDTYPE

    OCTETSTRING

    SIZE (128) The ONU ID TYPE (MAC, LOID)

    ONUIDOCTETSTRING

    SIZE (128)

    The ONU ID, and its value can beone of the following four items:MAC, LOID. It is used to uniquelyidentify an ONU connected with theappointed PON port.

    ONUPORTOCTETSTRING

    SIZE (128)Cabinet-subrack-slot- portNo.

    A card port is identified by thecabinet -subrack-slot-port No., andin the absence of any of the cabinet,subrack, slot, PON port No., fill withNA.

    UV INTEGER 0 to 4095 The subscriber side VLAN

    MVLAN INTEGER 0 to 4095 The related multicast VLAN

    Example

    Command:

    ADD- LANI PTVPORT: : OLTI D=133. 5. 35. 235, PONI D=NA- NA- 4- 4, ONUI DTYPE=MAC, ONUID=54- 5B-04- B3-43- A0, ONUPORT=NA- NA- NA- 1: CTAG: : UV=100, MVLAN=88;

    Response:

    10. 22. 16. 22 2007- 03- 01 13: 35: 00M CTAG COMPLD

    EN=0 ENDESC=No er r or

    Meaning:

    This command is used to add the NA-NA-NA-1 LAN port of the54-5B-04-B3-43-A0 ONU into a multicast group.

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    56/172

    ANM2000 Network Management System Northbound Interface (TL1) Operation Manual

    3-18 Version: A

    3.2.9 Deleting a LAN Port f rom a Multicast Group

    Functions

    This command is used to delete a LAN port from a multicast group.

    Command format

    DEL- LANI PTVPORT: : ONUI P=onu- name| OLTI D=ol t - name[ , PONI D=ponport _l ocat i on

    , ONUI DTYPE=onui d- t ype, ONUI D=onu- i ndex], ONUPORT=onu-por t : CTAG: : [ UV=uservl an] [ , MVLAN=mvl an] ;

    Response format

    Complies with the response format mentioned in Section2.4.

    Parameters

    ParameterName

    Data Type Value Range Remark

    ONUIP OCTET STRING SIZE (128)The IP address, name, or ID of anONU with the management IP

    addressOLTID OCTET STRING SIZE (128)

    The IP address, name, or ID of anOLT

    PONID OCTET STRING

    SIZE (128)Cabinet-subrack-slot-PONport No.

    The PON port identity information. APON port is identified by the cabinet-subrack-slot-PON port No., and inthe absence of any of the cabinet,subrack, slot, PON port No., fill withNA.

    ONUIDTYPE OCTET STRING SIZE (128) The ONU ID type (MAC, LOID)

    ONUID OCTET STRING SIZE (128)

    The ONU ID, and its value can beone of the following four items:MAC, LOID. It is used to uniquelyidentify an ONU connected with theappointed PON port.

    ONUPORT OCTET STRING

    SIZE (128)

    Cabinet-subrack-slot- portNo.

    A card port is identified by thecabinet -subrack-slot-port No., and

    in the absence of any of the cabinet,subrack, slot, PON port No., fill withNA.

    UV INTEGER 0 to 4095 The subscriber side VLAN

    MVLAN INTEGER 0 to 4095 The related multicast VLAN

    Example

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    57/172

    3 TL1 Commands

    Version: A 3-19

    Command:

    DEL- LANI PTVPORT: : OLTI D=133. 5. 35. 235, PONI D=NA- NA- 4- 4, ONUI DTYPE=MAC, ONUID=54- 5B-04- B3-43- A0, ONUPORT=NA- NA- NA- 1: CTAG: : UV=100, MVLAN=88;

    Response:

    10. 22. 16. 22 2007- 03- 01 13: 35: 00M CTAG COMPLDEN=0 ENDESC=No er r or

    Meaning:

    This command is used to delete the NA-NA-NA-1 LAN port of the54-5B-04-B3-43-A0 ONU from a multicast group.

    3.2.9 Configuring the IPTV Service Information of a LANPort

    Functions

    This command is used to configure the IPTV service information of a LAN port.

    Command format

    CFG- LANI PTVPORT: : ONUI P=onu- name| OLTI D=ol t - name[ , PONI D=ponport _l ocat i on, ONUI DTYPE=onui d- t ype, ONUI D=onu- i ndex], ONUPORT=onu-por t : CTAG: : [ FLMODE=i ptv- f ast l eave-mode] [ , MAXGRP=Max-group- number ] ;

    Response format

    Complies with the response format mentioned in Section 2.4.

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    58/172

    ANM2000 Network Management System Northbound Interface (TL1) Operation Manual

    3-20 Version: A

    Parameters

    ParameterName

    Data Type Value Range Remark

    ONUIPOCTETSTRING

    SIZE (128)The IP address, name, or ID of anONU with the management IPaddress

    OLTIDOCTETSTRING

    SIZE (128)The IP address, name, or ID of anOLT

    PONIDOCTETSTRING

    SIZE (128)Cabinet-subrack-slot-PONport No.

    The PON port identity information. APON port is identified by the cabinet-subrack-slot-PON port No., and inthe absence of any of the cabinet,subrack, slot, PON port No., fill with

    NA.ONUIDTYPE

    OCTETSTRING

    SIZE (128) The ONU ID type (MAC, LOID)

    ONUIDOCTETSTRING

    SIZE (128)

    The ONU ID, and its value can be oneof the following four items: MAC,LOID. It is used to uniquely identify anONU connected with the appointedPON port.

    ONUPORTOCTETSTRING

    SIZE (128)Cabinet-subrack-slot- portNo.

    A card port is identified by the cabinet-subrack-slot-port No., and in theabsence of any of the cabinet,subrack, slot, PON port No., fill withNA.

    FLMODEOCTETSTRING

    SIZE (32)The fast leave mode:EnabledDisabled

    MAXGRP INTEGER 0 to 255

    Means the maximum multicast

    program number a port is allowed tojoin at a time.

    Example

    Command:

    CFG- LANI PTVPORT: : OLTI D=133. 5. 35. 235, PONI D=NA- NA- 4- 4, ONUI DTYPE=MAC, ONUID=54- 5B-04- B3-43- A0, ONUPORT=NA- NA- NA- 1: CTAG: : FLMODE=1, MAXGRP=35;

    Response:

    10. 22. 16. 22 2007- 03- 01 13: 35: 00M CTAG COMPLD

    EN=0 ENDESC=No er r or

    Meaning:

    This command is used to configure the IPTV service information of theNA-NA-NA-1 LAN port on the 54-5B-04-B3-43-A0 ONU.

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    59/172

    3 TL1 Commands

    Version: A 3-21

    3.2.10 Configuring the VLAN Information of a LAN Port

    Functions

    This command is used to configure the VLAN information of a LAN port.

    Command format

    CFG- LANPORTVLAN: : ONUI P=onu-name| OLTI D=ol t - name[ , PONI D=ponpor t _l ocat i on, ONUI DTYPE=onui d- t ype, ONUI D=onu- i ndex], ONUPORT=onu-por t : CTAG: : [ SVLAN=o

    uter vl an] , CVLAN=I nner vl an[ , UV=user vl an] [ , SCOS=out er qos] [ , CCOS=i nnerqos];

    Response format

    Complies with the response format mentioned in Section 2.4.

    Parameters

    ParameterName

    Data Type Value Range Remark

    ONUIPOCTETSTRING

    SIZE (128)The IP address, name, or ID of anONU with the management IP

    addressOLTID

    OCTETSTRING

    SIZE(128)The IP address, name, or ID of anOLT

    PONIDOCTETSTRING

    SIZE (128)Cabinet-subrack-slot-PONport No.

    The PON port identity information. APON port is identified by the cabinet-subrack-slot-PON port No., and inthe absence of any of the cabinet,subrack, slot, PON port No., fill withNA.

    ONUIDTYPEOCTETSTRING

    SIZE(128) The ONU ID type (MAC, LOID)

    ONUIDOCTETSTRING

    SIZE(128)

    The ONU ID, and its value can beone of the following four items:MAC, LOID. It is used to uniquelyidentify an ONU connected with theappointed PON port.

    ONUPORT OCTETSTRING

    SIZE (128)

    Cabinet-subrack-slot- portNo.

    A card port is identified by the

    cabinet -subrack-slot-port No., andin the absence of any of the cabinet,subrack, slot, PON port No., fill withNA.

    SVLAN INTEGER 0 to 4095 The SVLAN

    CVLAN INTEGER 0 to 4095 The CVLAN

    UV INTEGER 0 to 4095 The User VLAN

    SCOS INTEGER 0 to 7The priority information carried bythe SVLAN

    CCOS INTEGER 0 to 7The priority information carried bythe CVLAN

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    60/172

    ANM2000 Network Management System Northbound Interface (TL1) Operation Manual

    3-22 Version: A

    Example

    Command:

    CFG- LANPORTVLAN: : OLTI D=133. 5. 35. 234, PONI D=NA- NA- 4- 1, ONUI DTYPE=MAC, ONUID=54- 5B-04- B3-43- A0, ONUPORT=NA- NA- NA- 1: CTAG: : SVLAN=510, CVLAN=1301, UV=487;

    Response:

    10. 22. 16. 22 2007- 03- 01 13: 35: 00M CTAG COMPLDEN=0 ENDESC=No er r or

    Meaning:

    This command is used to configure the VLAN information of the NA-NA-NA-1 LANport on the 54-5B-04-B3-43-A0 ONU.

    3.2.11 Deleting the VLAN Information from a LAN Port

    Functions

    This command is used to delete the VLAN information from a LAN port on anFTTH ONU.

    Command format

    DEL- LANPORTVLAN: : ONUI P=onu-name| OLTI D=ol t - name[ , PONI D=ponpor t _l ocat i on, ONUI DTYPE=onui d- t ype, ONUI D=onu- i ndex], ONUPORT=onu-por t : CTAG: : [ UV=uservl an];

    Response format

    Complies with the response format mentioned in Section 2.4.

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    61/172

    3 TL1 Commands

    Version: A 3-23

    Parameters

    ParameterName

    Data Type Value Range Remark

    ONUIP OCTET STRING SIZE (128)The IP address, name, or ID of anONU with the management IPaddress

    OLTID OCTET STRING SIZE (128)The IP address, name, or ID of anOLT

    PONID OCTET STRING

    SIZE (128)Cabinet-subrack-slot-PONport No.

    The PON port identity information. APON port is identified by the cabinet-subrack-slot-PON port No., and inthe absence of any of the cabinet,subrack, slot, PON port No., fill with

    NA.ONUIDTYPE OCTET STRING SIZE (128) The ONU ID type (MAC, LOID)

    ONUID OCTET STRING SIZE (128)

    The ONU ID, and its value can be oneof the following four items: MAC,LOID. It is used to uniquely identify anONU connected with the appointedPON port.

    ONUPORT OCTET STRING

    SIZE (128)Cabinet-subrack-slot- portNo.

    A card port is identified by the cabinet-subrack-slot-port No., and in theabsence of any of the cabinet,subrack, slot, PON port No., fill withNA.

    UV INTEGER 0 to 4095 The User VLAN

    Example

    Command:

    DEL- LANPORTVLAN: : OLTI D=133. 5. 35. 234, PONI D=NA- NA- 4- 1, ONUI DTYPE=MAC, ONUID=54- 5B-04- B3-43- A0, ONUPORT=NA- NA- NA- 1: CTAG: : UV=487;

    Response:

    10. 22. 16. 22 2007- 03- 01 13: 35: 00M CTAG COMPLDEN=0 ENDESC=No er r or

    Meaning:

    This command is used to delete the VLAN information of the NA-NA-NA-1 LANport on the 54-5B-04-B3-43-A0 ONU.

    3.2.12 Adding an ONU

    Functions

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    62/172

    ANM2000 Network Management System Northbound Interface (TL1) Operation Manual

    3-24 Version: A

    This command is used to add an ONU.

    Command format

    ADD- ONU: : OLTI D=ol t - name, PONI D=ponport _l ocat i on: CTAG: : [ AUTHTYPE=auth- t ype, ] ONUI D=onu- i ndex[ , NAME=name] , ONUTYPE=onu t ype;

    Response format

    Complies with the response format mentioned in Section 2.4.

    Parameters

    ParameterName

    Data Type Value Range Remark

    OLTID OCTET STRING SIZE (128)The IP address, name, or ID of anOLT

    PONID OCTET STRING

    SIZE (128)Cabinet-subrack-slot-PONport No.

    The PON port identity information. APON port is identified by the cabinet-subrack-slot-PON port No., and inthe absence of any of the cabinet,subrack, slot, PON port No., fill withNA.

    AUTHTYPE

    OCTET STRING SIZE (128) ONU authorize type(MAC,LOID)

    ONUID OCTET STRING SIZE (128) The ONU ID (LOID)

    PWD OCTET STRING SIZE (128) The LOID passwordNAME OCTET STRING SIZE (128) The ONU name

    ONUTYPE OCTET STRING SIZE (32) The ONU type

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    63/172

    3 TL1 Commands

    Version: A 3-25

    Example

    Command:

    ADD- ONU: : OLTI D=133. 5. 35. 235, PONI D=NA- NA- 4- 4: CTAG: : AUTHTYPE=MAC, ONUTYPE=AN5006- 04, ONUI D=54- 5B- 04- B3- 43- A0;

    Response:

    10. 22. 16. 22 2007- 03- 01 13: 35: 00M CTAG COMPLD

    EN=0 ENDESC=No er r or

    Meaning:

    This command is used to add an AN5006-04 ONU to the 133.5.35.235 OLT.

    3.2.13 Deleting an ONU

    Functions

    This command is used to delete an ONU.

    Command format

    DEL- ONU: : OLTI D=ol t - name, PONI D=ponport _l ocat i on: CTAG: : ONUI DTYPE=onui d- type, ONUI D=onu- i ndex;

    Response format

    Complies with the response format mentioned in Section 2.4.

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    64/172

    ANM2000 Network Management System Northbound Interface (TL1) Operation Manual

    3-26 Version: A

    Parameters

    ParameterName

    Data Type Value Range Remark

    OLTID OCTET STRING SIZE (128) The IP address, name, or ID of an OLT

    PONID OCTET STRING

    SIZE (128)Cabinet-subrack-slot-PON port No.

    The PON port identity information. APON port is identified by the cabinet-subrack-slot-PON port No., and in theabsence of any of the cabinet,subrack, slot, PON port No., fill withNA.

    ONUIDTYPE OCTET STRING SIZE (128) The ONU ID type (MAC, LOID)

    ONUID OCTET STRING SIZE (128)

    The ONU ID, and its value can be one

    of the following four items: MAC, LOID.It is used to uniquely identify an ONUconnected with the appointed PONport.

    Example

    Command:

    DEL- ONU: : OLTI D=133. 5. 35. 235, PONI D=NA- NA- 4- 4: CTAG: : ONUI DTYPE=MAC, ONUTYPE=AN5006- 04, ONUI D=54- 5B- 04- B3- 43- A0;

    Response:

    10. 22. 16. 22 2007- 03- 01 13: 35: 00M CTAG COMPLDEN=0 ENDESC=No er r or

    Meaning:

    This command is used to delete an AN5006-04 ONU from the 133.5.35.235 OLT.

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    65/172

    3 TL1 Commands

    Version: A 3-27

    3.3 Integrated Test Interface

    3.3.1 PON Service

    3.3.1.1 Pinging an IP from the Equipment (PING)

    Functions

    This function is used to test the VoIP channel.

    Command format

    PI NG: : ONUI P=onu name| OLTI D=OLT_name[ , PONI D=ponpor t _l ocat i on, ONUI DTYPE=i d- t ype, ONUI D=onu_i ndex]: CTAG: : I P=i p- address ;

    Response format

    Complies with the response format on query commands mentioned in Section 2.4.

    t i t l e = Pi ng f romONU

    Input parameter

    Parameter Name Data Type Value Range Remark

    ONUIP OCTET STRING SIZE (128)

    The IP address, name,or ID of an ONU withthe management IPaddress

    OLTID OCTET STRING SIZE (128)The IP address, name,or ID of an OLT

    PONID OCTET STRING

    SIZE (128)Cabinet

    -subrack-slot-PONport No.

    The PON port identityinformation. A PON portis identified by thecabinet

    -subrack-slot-PON portNo., and in the absenceof any of the cabinet,subrack, slot, PON portNo., fill with NA.

    ONUIDTYPE OCTET STRING

    SIZE (128)ONU_NAME,MAC,LOID,ONU_NUMBER

    The ONU ID type(ONU_NAME, MAC,LOID, ONU_NUMBER)

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    66/172

    ANM2000 Network Management System Northbound Interface (TL1) Operation Manual

    3-28 Version: A

    Parameter Name Data Type Value Range Remark

    ONUID OCTET STRING SIZE (128)

    The ONU ID, and itsvalue can be one of thefollowing four items:ONU_NAME, MAC,LOID, ONU_NUMBER.It is used to uniquelyidentify an ONUconnected with theappointed PON port.

    IP OCTET STRING SIZE (20)The target IP addressof the ping operation

    Output parameter

    Parameter Name Data Type Value Range Remark

    TxPkts INTEGER 0 to 10The number of Txpackets

    RxPkts INTEGER 0 to 10The number of Rxpackets

    LostPkts INTEGER 0 to 10The number of lostpackets

    LostPktRatio INTEGER 0 to 100 Packet loss rate

    MinDelay INTEGER 0 to 2000Minimum delay timeUnit: ms

    MaxDelay INTEGER 0 to 2000Maximum delay timeUnit: ms

    AvgDelay INTEGER 0 to 2000Average delay timeUnit: ms

    Example

    Command:

    PI NG: : ONUI P=133. 5. 35. 237: CTAG: : I P=134. 140. 55. 130;

    Response:

    FH_134. 140. 55. 130 2010- 07- 01 11: 19: 48M CTAG COMPLDt otal _bl ocks=1bl ock_number =1bl ock_r ecords=1Pi ng f r om ONU- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -TxPkt s RxPkt s Lost Pkt s Lost Pkt Rat i o Mi nDel ay MaxDel ay

    AvgDel ay2 2 0 0 16 0 8

    Meaning:

    This command is used to ping the 134.140.55.130 OLT from the 133.5.35.237ONU.

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    67/172

    3 TL1 Commands

    Version: A 3-29

    3.3.1.2 Querying the NE Equipment Information (LST-DEVINFO)

    Functions

    Query the equipment type, software version, memory, CPU, temperature, andother information of a certain NE (OLT and ONU).

    Command format

    LST- DEVI NFO: : ONUI P=onu- name| OLTI D=ol t - name[ , PONI D=ponport - l ocat i on, ONUI DTYPE=i d- t ype, ONUI D=onu- i ndex]: CTAG: : ;

    Response format

    Complies with the response format on query commands mentioned in Section 2.4.

    t i t l e = Pi ng f romONU

    Input parameter

    Parameter Name Data Type Value Range Remark

    ONUIP OCTET STRING SIZE (128)

    The IP address, name, or ID

    of an ONU with themanagement IP address

    OLTID OCTET STRING SIZE (128)The IP address, name, or IDof an OLT

    PONID OCTET STRING

    SIZE (128)Cabinet-subrack-slot-PONport No.

    The PON port identityinformation. A PON port isidentified by the cabinet-subrack-slot-PON port No.,and in the absence of any ofthe cabinet, subrack, slot,PON port No., fill with NA.

    ONUIDTYPE OCTET STRING

    ONU_NAME,MAC,LOID,ONU_NUMBER

    The ONU ID type(ONU_NAME, MAC, LOID,ONU_NUMBER)

    ONUID OCTET STRING SIZE (128)

    The ONU ID, and its valuecan be one of the following

    four items: ONU_NAME,MAC, LOID,ONU_NUMBER. It is used touniquely identify an ONUconnected with theappointed PON port.

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    68/172

    ANM2000 Network Management System Northbound Interface (TL1) Operation Manual

    3-30 Version: A

    Output parameter

    Parameter Name Data Type Value Range Remark

    DEVNAME OCTET STRING SIZE (128) The equipment name

    DEVIP OCTET STRING SIZE (128) The equipment IP address

    DT OCTET STRING SIZE (255) The equipment type

    DEVER OCTET STRING SIZE (255) The software version

    MEM INTEGER 0 to100The memory utilization ratioUnit: %

    CPU INTEGER 0 to100The CPU utilizationUnit: %

    TEMPERATURE INTEGER -50 to 100The temperature

    Unit:

    Example

    Command:

    LST- DEVI NFO: : OLTI D=133. 5. 35. 234, PONI D=NA-NA-4- 1, ONUI DTYPE=LOI D, ONUI D=hg220sn_1: CTAG: : ;

    Response:

    Li st of Devi ce I nf o- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -DEVNAME DEVI P DT DEVER MEM CPU TEMPERATURE

    - - - - HG220 ! ! RP0100 - - - - - -

    Meaning:

    This command is used to query the NE equipment information of the ONU whoseSN is hg220sn_1 connected to the 133.5.35.234 OLT.

    3.3.1.3 Querying the Card Information (LST-BRDINFO)

    Functions

    Query the type, status, version, etc. of a certain card.

    Command format

    LST- BRDI NFO: : ONUI P=onu- name| OLTI D=ol t - name[ , PONI D=ponport _l ocat i on, ONUI DTYPE=i d- t ype, ONUI D=onu_i ndex] [ , BOARDI D=boar d- name] : CTAG: : ;

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    69/172

    3 TL1 Commands

    Version: A 3-31

    Response format

    Complies with the response format on query commands mentioned in Section 2.4.

    t i t l e = Pi ng f romONU

    Input parameter

    ParameterName

    Data Type Value Range Remark

    ONUIPOCTETSTRING

    SIZE (128)The IP address, name, or ID of anONU with the management IPaddress

    OLTID OCTETSTRING

    SIZE (128) The IP address, name, or ID of anOLT

    PONIDOCTETSTRING

    SIZE (128)Cabinet-subrack-slot-PONport No.

    The PON port identity information. APON port is identified by the cabinet-subrack-slot-PON port No., and inthe absence of any of the cabinet,subrack, slot, PON port No., fill withNA.

    ONUIDTYPEOCTETSTRING

    ONU_NAME,MAC,LOID,ONU_NUMBER

    The ONU ID type (ONU_NAME,MAC, LOID, ONU_NUMBER)

    ONUIDOCTETSTRING

    SIZE (128)

    The ONU ID, and its value can beone of the following four items:ONU_NAME, MAC, LOID,ONU_NUMBER. It is used touniquely identify an ONU connected

    with the appointed PON port.

    BOARDIDOCTETSTRING

    SIZE (128)Cabinet -subrack-slot

    The card identity information. A cardis located in the cabinet-subrack-slot No. mode, and in theabsence of any of the cabinet,subrack, slot, PON port No., fill withNA.

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    70/172

    ANM2000 Network Management System Northbound Interface (TL1) Operation Manual

    3-32 Version: A

    Output parameter

    ParameterName

    Data Type Value Range Remark

    BOARDIDOCTETSTRING

    SIZE (128)Cabinet-subrack-slot

    The card identity information. A card islocated in the cabinet -subrack-slot No.mode, and in the absence of any of thecabinet, subrack, slot, PON port No., fillwith NA.

    BSTATOCTETSTRING

    NormalFaultOffline

    The card status

    BOARDTYPEOCTETSTRING

    SIZE (128) The card type

    BSERVICEOCTETSTRING

    PowerETH

    ADSLVDSLPOTSE1GPONEPONSCUOther

    The card service type (such as theADSL2P, the SHDSL)

    PNUM INTEGER 0 to 64 The number of ports

    SWVEROCTETSTRING

    SIZE (255) The software version

    HWVEROCTETSTRING

    SIZE (255) The hardware version

    MEM INTEGER 0 to100The memory utilization ratioUnit: %

    CPU INTEGER 0 to 100 The CPU utilizationUnit: %

    Example

    Command:

    LST- BRDI NFO: : OLTI D=133. 5. 35. 235, BOARDI D=NA- NA- 4: CTAG: : ;

    Response:

    DEVNAME DEVI P DT DEVER MEM CPU TEMPERATURE237_AN5006- 20 133. 5. 35. 237AN5006- 20 RP0106 64. 29 2. 33 38

    Meaning:

    This command is used to query the information of the card in slot 4 of the133.5.35.235 OLT.

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    71/172

    3 TL1 Commands

    Version: A 3-33

    3.3.1.4 Querying the ETH Performance (LST-LANPERF)

    Functions

    Query the ETH performance of an OLT uplink port or an ONU LAN port.

    Command format

    LST- LANPERF: :ONUI P=onu_name| OLTI D=ol t _name[ , PONI D=ponport _l ocat i on, ONUI DTYPE=i d- t yp

    e, ONUI D=onu_i ndex], PORTI D=l anpor t _i ndex: CTAG: : ;

    Response format

    Complies with the response format on query commands mentioned in Section 2.4.

    Ti t l e = Li st of Et henet per f or mance

    Output parameter

    Parameter Name Data Type Value Range Remark

    OutPkts DOUBLE 0 to 1.85E19 The number of Tx packets

    InPkts DOUBLE 0 to1.85E19 The number of Rx packets

    OutOctets DOUBLE 0 to1.85E19 The number of Tx bytes

    InOctets DOUBLE 0 to1.85E19 The number of Rx bytes

    CRC DOUBLE 0 to1.85E19The number of Rx CRC erroredmessages

    UnderSizePkts DOUBLE 0 to1.85E19The number of Rx under-sizemessages

    OverSizePkts DOUBLE 0 to1.85E19The number of Rx over-sizemessages

    InErrors DOUBLE 0 to1.85E19The number of Rx erroredmessages

    OutErrors DOUBLE 0 to1.85E19The number of non-Tx erroredmessages

    InDiscards DOUBLE 0 to1.85E19The number of discarded Rxmessages

    OutDiscards DOUBLE 0 to1.85E19The number of discarded Txmessages

    InUnicastPkts DOUBLE 0 to1.85E19 The number of Rx unicast packets

    InMulticastPkts DOUBLE 0 to1.85E19 The number of Rx multicast packets

    InBroadcastPkts DOUBLE 0 to1.85E19The number of Rx broadcastpackets

    OutUnicastPkts DOUBLE 0 to1.85E19 The number of Tx unicast packets

    OutMulticastPkts DOUBLE 0 to1.85E19 The number of Tx multicast packets

    OutBroadcastPkts DOUBLE 0 to1.85E19The number of Tx broadcastpackets

    StateChangeCounters

    INTEGER0 to4294967295

    The port status changing times

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    72/172

    ANM2000 Network Management System Northbound Interface (TL1) Operation Manual

    3-34 Version: A

    Example

    Command:

    LST- LANPERF: : OLTI D=133. 5. 35. 234, PORTI D=NA- NA- 29- 1: CTAG: : ;

    Response:

    Li st of Ethenet perf ormance- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -OutPkt s I nPkt s OutOct ets I nOct ets CRC UnderSi zePkt sOver Si zePkts I nEr r ors Out Er r ors I nDi scards Out Di scar dsI nUni cast Pkt s I nMul t i cast Pkt s I nBr oadcast Pkt s Out Uni cast Pkt s

    OutMul t i cast Pkt s OutBr oadcastPkt s StateChangeCounters

    6889 643 198010 509876 0 0 0 0 - - 0 - - 197 37 6655 - -0 98 - -

    Meaning:

    This command is used to query the information of the uplink port 29 of the card inslot 1 under the 133.5.35.234 OLT.

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    73/172

    3 TL1 Commands

    Version: A 3-35

    3.3.1.5 Querying the PON Port Information (LST-PONINFO)

    Functions

    Query the status and configuration information of an OLT PON port.

    Command format

    LST- PONI NFO: : OLTI D=ol t - name, PONI D=pon_name: CTAG: : ;

    Response format

    Complies with the response format on query commands mentioned in Section 2.4.

    Ti t l e = Li st of ol t pon port i nf or mat i on

    Input parameter

    ParameterName

    Data Type Value Range Remark

    OLTID OCTET STRING SIZE (128)The IP address, name, or ID of anOLT

    PONID OCTET STRING

    SIZE (128)Cabinet-subrack-slot-PONport No.

    The PON port identity information.

    A PON port is identified by thecabinet -subrack-slot-PON portNo., and in the absence of any ofthe cabinet, subrack, slot, PONport No., fill with NA.

    Output parameter

    ParameterName

    Data Type Value Range Remark

    AdminState OCTET STRINGUPDOWN

    The management status

    OperState OCTET STRINGUPDOWN

    The running status

    Example

    Command:

    AN5116- 02:

    LST- PONI NFO: : OLTI D=133. 5. 35. 234, PONI D=NA- NA- 4- 1: CTAG: : ;

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    74/172

    ANM2000 Network Management System Northbound Interface (TL1) Operation Manual

    3-36 Version: A

    Response:

    Li st of Boar d I nf o- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -BOARDI D BSTAT BOARDTYPE BSERVI CE PNUM SWVER HWVER MEMCPUNA-1- 4 Nor mal EC4B EPON 4 RP0201 WKE2. 119. 318R1A - - - -

    Meaning:

    This command is used to query the information of the PON port 1 of the card inslot 4 under the 133.5.35.234 OLT.

    3.3.1.6 Querying the ONU Configuration Information(LST-ONUCFG)

    Functions

    Query the configuration information of an ONU from the OLT, including the ONUstatus, the optical fiber length, the authentication information, etc.

    Command format

    LST- ONUCFG: :OLTI D=ol t - name, PONI D=ponport _l ocat i on, ONUI DTYPE=i d- t ype, ONUI D=onu- i ndex: CTAG: : ;

    Response format

    Complies with the response format on query commands mentioned in Section 2.4.

    Ti t l e = l i st of ONU i nf o

    Input parameter

    ParameterName

    Data Type Value Range Remark

    OLTID OCTET STRING SIZE (128) The IP address, name, or ID ofan OLT

    PONID OCTET STRING

    SIZE (128)Cabinet-subrack-slot-PONport No.

    The PON port identityinformation. A PON port isidentified by the cabinet-subrack-slot-PON port No., andin the absence of any of thecabinet, subrack, slot, PON portNo., fill with NA.

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    75/172

    3 TL1 Commands

    Version: A 3-37

    ParameterName

    Data Type Value Range Remark

    ONUIDTYPE OCTET STRING

    ONU_NAME,MAC,LOID,ONU_NUMBER

    The ONU ID type (ONU_NAME,MAC, LOID, ONU_NUMBER)

    ONUID OCTET STRING SIZE (128)

    The ONU ID, and its value canbe one of the following fouritems: ONU_NAME, MAC,LOID, ONU_NUMBER. It isused to uniquely identify anONU connected with theappointed PON port.

    Output parameter

    ParameterName

    Data Type Value Range Remark

    AdminState OCTET STRINGUPDOWN

    The management status

    OperState OCTET STRINGUPPower-OffLOS

    The running status

    AUTH OCTET STRINGMACLOID

    The authentication mode

    AUTHINFO OCTET STRING SIZE (64)

    The authentication information.If AUTH is set to MAC,

    AUTHINFO means the MACaddress; If AUTH is set to LOID,

    AUTHINFO means the LOIDvalue.

    Length INTEGER 0 to 100The optical fiber length

    Unit: kmUsFixedBw INTEGER 0 to 40000

    The uplink fixed bandwidthUnit: Mbit/s

    UsAssuredBw

    INTEGER 0 to 40000The uplink assured bandwidthUnit: Mbit/s

    UsMaxBw INTEGER 0 to 40000The uplink maximum bandwidthUnit: Mbit/s

    DsMaxBw INTEGER 0 to 40000The downlink maximumbandwidthUnit: Mbit/s

    Example

    Command:

    LST- ONUCFG: : OLTI D=133. 5. 35. 234, PONI D=NA- NA- 4- 1, ONUI DTYPE=LOI D, ONUI D=511603: CTAG: : ;

    Response:

    l i st of ONU i nf o- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -Admi nStat e OperSt at e AUTH AUTHI NFO Length UsFi xedBwUsAssur edBw UsMaxBw DsMaxBwUP UP LOI D 551607 0. 002 0 0 1000 1000

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    76/172

    ANM2000 Network Management System Northbound Interface (TL1) Operation Manual

    3-38 Version: A

    Meaning:

    This command is used to query the configuration information of the ONU underPON port 1 of the card in slot 4 under the 133.5.35.234 OLT.

    3.3.1.7 Querying the ONU Status (LST-ONUSTATE)

    Functions

    Query the status and authentication information of an ONU or all ONUs under thePON port of an OLT.

    Command format

    LST- ONUSTATE: :OLTI D=ol t - name, PONI D=ponport _l ocat i on[, ONUI DTYPE=i d- t ype, ONUI D=onu- i ndex] : CTAG: : ;

    Response format

    Complies with the response format on query commands mentioned in Section 2.4.

    Ti t l e = l i st of ONU st at e

    Input parameter

    Parameter Name Data Type Value Range Remark

    OLTID OCTET STRING SIZE (128)The IP address, name, or IDof an OLT

    PONID OCTET STRING

    SIZE (128)Cabinet-subrack-slot-PON port No.

    The PON port identityinformation. A PON port isidentified by the cabinet-subrack-slot-PON port No.,and in the absence of any ofthe cabinet, subrack, slot,PON port No., fill with NA.

    ONUIDTYPE OCTET STRING

    ONU_NAME,MAC,LOID,ONU_NUMBER

    The ONU ID type

    (ONU_NAME, MAC, LOID,ONU_NUMBER)

    ONUID OCTET STRING SIZE (128)

    The ONU ID, and its value canbe one of the following fouritems: ONU_NAME, MAC,LOID, ONU_NUMBER. It isused to uniquely identify anONU connected with theappointed PON port.

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    77/172

    3 TL1 Commands

    Version: A 3-39

    Output parameter

    Parameter Name Data Type Value Range Remark

    ONUID OCTET STRING SIZE (128)

    The ONU ID, and its value isONU_Number. It is used touniquely identify an ONUconnected with the appointedPON port.

    AdminState OCTET STRINGUPDOWN

    The management status

    OperState OCTET STRINGUPPower-OffLOS

    The running status

    AUTH OCTET STRINGMACLOID

    The authentication mode

    AUTHINFO OCTET STRING SIZE (64)

    The authentication information.If AUTH is set to MAC,

    AUTHINFO means the MACaddress; If AUTH is set toLOID, AUTHINFO means theLOID value.

    ONUIP OCTET STRINGThe ONU management IPaddress

    Example

    Command:

    LST- ONUSTATE: : OLTI D=133. 5. 35. 235, PONI D=NA-NA-4- 4, ONUI DTYPE=LOI D, ONUI D=551607: CTAG: : ;

    Response:

    l i st of ONU st at e- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -ONUI D Admi nSt at e Oper St at e AUTH AUTHI NFO ONUI P1 UP UP LOI D 551607 - -

    Meaning:

    This command is used to query the configuration status information of the ONUunder PON port 4 of the card in slot 4 under the 133.5.35.235 OLT.

  • 5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual

    78/172

    ANM2000 Network Management System Northbound Interface (TL1) Operation Manual

    3-40 Version: A

    3.3.1.8 Querying the Optical Module DDM Information(LST-OMDDM)

    Functions

    Querying the DDM information of an optical module, and the optical module canbe an ETH optical module, an OLT PON optical module, or an ONU PON opticalmodule.

    Command format

    LST- OMDDM: : ONUI P=onu- name| OLTI D=ol t - name[ , PONI D=ponport _l ocat i on][ , ONUI DTYPE=i d- t ype, ONUI D=onu- i ndex][ , PORTI D=l anpor t _i ndex] [ , PEERFLAG=f l ag]: CTAG: : ;

    Input parameter

    Parameter Name Data Type Value Range Remark

    ONUIP OCTET STRING SIZE (128)The IP address, name, or IDof an ONU with themanagement IP address.

    OLTID OCTET STRING SIZE (128)The IP address, name, or IDof an OLT

    PONID OCTET STRING

    SIZE (128)Cabinet-subrack-slot-PONport No.

    The PON port identity

    information. A PON port isidentified by the cabinet-subrack-slot-PON port No.,and in the absence of any ofthe cabinet, subrack, slot,PON port No., fill with NA.

    ONUIDTYPE OCTET STRING

    ONU_NAME,MAC,LOID,ONU_NUMBER

    The ONU ID type(ONU_NAME, MAC, LOID,ONU_NUMBER)

    ONUID OCTET STRING SIZE (128)

    The ONU ID, and its valuecan be one of the followingfour items: ONU_NAME,MAC, LOID,ONU_NUMBER. It is used touniquely identify an ONUconnected with the

    appointed PON port.

    PORTID OCTET STRING

    SIZE (128)Cabinet-subrack-slot-portNo.

    A card is identified by thecabinet -subr