FIRE FACTS GUIDE For iLevel ® Engineered Lumber Products www.iLevel.com 1.888.iLevel8 (1.888.453.8358) ROOF SOLUTIONS FLOOR SOLUTIONS Thorough Fire Testing Design and Construction Assistance Proven Fire Performance Long-Standing Research and Development Limited Product Warranty WALL SOLUTIONS #1500 FIRE FACTS GUIDE

Transcript of WALL SOLUTIONS ROOF SOLUTIONS FIRE FACTS GUIDE · Floors, roofs, and walls can be assembled in...

Page 1: WALL SOLUTIONS ROOF SOLUTIONS FIRE FACTS GUIDE · Floors, roofs, and walls can be assembled in three ways: 1. Unrated, unprotected assemblies: Structural members are exposed (without

FIRE FACTSGUIDEFor iLevel® Engineered Lumber Products

www.iLevel.com 1.888.iLevel8 (1.888.453.8358)

ROOF SOLUTIONSFLOOR SOLUTIONS

■ Thorough Fire Testing

■ Design and Construction Assistance

■ Proven Fire Performance

■ Long-Standing Research and Development

■ Limited Product Warranty

WALL SOLUTIONS

#1500 FIRE FACTS GUIDE

Page 2: WALL SOLUTIONS ROOF SOLUTIONS FIRE FACTS GUIDE · Floors, roofs, and walls can be assembled in three ways: 1. Unrated, unprotected assemblies: Structural members are exposed (without

iLevel Trus Joist® Fire Facts Guide 1500 July 2008

INTRODUCTION

ABOUT FIRE-SAFE CONSTRUCTIONFire-safe construction and life safety are major concerns for everyone in

the building materials and construction industry. The 2006 U.S. Fire Administration (http://www.usfa.dhs.gov/statistics/national/) statistics on residential and commercial fires in the U.S. alone include 3,245 fire fatalities and an estimated $11.3 billion in property damage. These numbers underscore the seriousness of the issue and the need for fire-safe construction.

For nearly 40 years, prefabricated wood I-joists and other iLevel building products have established a record of safe and reliable performance in millions of structures. Many of these structures, such as one- or two-family residential dwellings, do not require specific fire-resistance ratings per building codes. The following information is intended to help you specify and install iLevel® Trus Joist® and Structurwood® brand products with fire safety in mind.

Fire-Resistance CategoriesThere are two categories of construction: fire-resistance rated and unrated.

Fire-resistance-rated construction requirements govern the following: ■ Materials and assemblies used for structural fire resistance ■ Fire-resistance-rated construction practices ■ Requirements for the separation of adjacent spaces that safeguard against the spread of fire and smoke

within a building, as well as the spread of fire between buildings.

Unrated construction does not require a fire-resistance rating because it relies on other forms of protection, including the following:■ Smaller areas of habitable space■ Multiple paths of exit, such as doors and windows■ Spacing between houses

Fire-Resistance-Rated ConstructionMulti-family and commercial buildings usually require fire-resistance-rated construction and sprinklers because of the structure’s square footage and height. Because single-family dwellings usually have less habitable space and a lower height, they remain unrated. In both cases, building codes require that a building provide occupants with sufficient means to exit the structure during a fire. The building’s construction must also maintain sufficient structural integrity and resist the spread of a fire.

In fire-resistance-rated construction, building codes specify that floor/ceiling, roof/ceiling, and wall assemblies be rated using a standard fire-resistance test, such as the ASTM E119 test standard. The ASTM E119 test was used to rate the assemblies listed in this guide. In order to maintain the fire-rating of an assembly, penetrations such as lights and vents must follow the specified installation methods and meet code requirements.

Unrated ConstructionIn unrated construction, the structural elements of single-family dwellings can consist of any material permitted by the building code. Required fire protection in single-family dwellings usually consists of separations between building sections, such as Type X gypsum board between the garage and habitable space. Unfinished basements may have exposed or unprotected floor joists or trusses.

Floors, roofs, and walls can be assembled in three ways:1. Unrated, unprotected assemblies: Structural members are exposed (without gypsum board) to the occupied

space. Neither structural members nor assembly have a required fire-resistance rating, except for flame spread.2. Unrated, membrane-protected assemblies: A non-fire-rated membrane, such as standard gypsum wallboard,

encloses the structural members. Neither the structural members nor the assembly have a fire-resistance rating, except for flame spread. Penetrations in the membrane for lighting are not regulated. The added membrane is considered passive protection. A single layer of ½" unrated gypsum board can contribute to the total fire resistance of the structural members without controlling an active fire. It is possible to add passive-type protection without specifying a fire-resistance rating.

3. Unrated assemblies with sprinklers: Fires are actively suppressed through code-approved (NFPA 13D) sprinkler systems. Sprinklers can be added to either unprotected or membrane-protected systems.

2

Fire Resistance 3–4Floor/Ceiling Assemblies 5–6Roof/Ceiling Assemblies 5–6Wall Assemblies 7–10Notes 11Q&A 12–15

TABLE OF CONTENTS

Page 3: WALL SOLUTIONS ROOF SOLUTIONS FIRE FACTS GUIDE · Floors, roofs, and walls can be assembled in three ways: 1. Unrated, unprotected assemblies: Structural members are exposed (without

iLevel Trus Joist® Fire Facts Guide 1500 July 2008 3

FIRE RESISTANCE

Active Fire Suppression Automatic fire sprinkler systems are commonly required by building codes in schools, office buildings, factories, and other commercial buildings. Buildings designed with sprinkler systems are allowed larger areas and a greater height than buildings designed without sprinkler systems.

Fire service agencies such as the U.S. Fire Administration promote the use of residential sprinkler systems. These agencies cite benefits such as lower overall cost of construction for the homebuilder, plus a safer environment and lower insurance rates for the homeowner. Using automatic fire sprinkler systems provides the following benefits:■ Early and unsupervised suppression■ Reduced fire and smoke development■ Potentially enhanced life safety for the occupant(s)

Passive Fire ProtectionIndependent tests show that, when compared to protected systems, unprotected framing systems (whether combustible or non-combustible) suffer increased structural degradation when exposed to fire. All floor framing materials—sawn lumber, wood I-joists, trusses, and light-gauge steel— succumb quickly to fire if not protected. Applying a protective membrane, such as gypsum ceiling board, to all types of floor framing within the structure will provide uniform protection to the structural framing members. Passive fire protection can do the following:■ Delay fire growth involving structural elements■ Reduce the potential for significant property damage to structural elements■ Enhance the market value of the building

Concealed Space ProtectionIn addition to protecting the occupied space, building codes for rated construction require construction techniques and materials that restrict the movement of air or flame to other areas in the building through concealed spaces. Typical framing methods leave voids between structural members and between membranes within a wall. During a fire, hot gases and flames can advance through these voids and carry the fire into ceiling spaces. Fire-blocking and draft-stopping in strategic locations help retard the advancement of a concealed-space fire while occupants safely exit the structure.

Examples of concealed-space protection include the following:■ Blocking between floor joists■ Blocking between the bottom and top plates of walls■ Framing around stairwell openings■ Sealing around penetrations for wiring or ventilation

The rated wall assemblies shown in this guide were designed to retard fire from penetrating the wall and advancing into the floor/ceiling space above or crossing to the adjacent floor system. These assembly designs address the requirements for fire-blocking in the concealed spaces of two-family and townhouse structures in order to maintain a continuous fire separation between dwelling units within or between buildings.

Some designs have unrated floor/ceiling assemblies as permitted by model building codes. Others have rated floor/ceiling assemblies that act as horizontal fire separations.

Center-wall designs provide the listed vertical fire resistance on both sides of the wall and are considered a single assembly.

End-wall designs provide the listed vertical fire resistance on the occupancy side of exterior walls and do not contain specific details for cladding on the exterior side of the vertical studs. End-wall designs can also be used for stairwells, provided that the gypsum on the stairwell side is the same as on the occupancy side.

These designs do not address model building code requirements for firewalls that provide a complete separation and structural independence between buildings, nor do they detail any requirements for separations beneath the roof deck. For additional information, see NFPA 221: Standard for High Challenge Fire Walls, Fire Walls, and Fire Barrier Walls or an official commentary to the building code.

Smoke DetectorsSmoke detectors are universally recognized as the most cost-effective life-saving devices. Although smoke detectors do not provide protection to the structure or to the contents in a home, they do alert occupants to potential fire hazards and allow them time to escape. Similarly, carbon monoxide detectors can also alert occupants to faulty heating appliances or air contamination in the early stages of a fire.

Char RatesRate of char is used to compare the rate of combustion between wood products. Although no ASTM or CAN/ULC test standards for char rate currently exist, most wood product testing laboratories burn the test specimen for a measured time period using a single radiant energy source, then extinguish the burn and measure the remaining section. The depth of char divided by the measured time period is the char rate. A lower char rate indicates a slower rate of burn.

Research conducted at the Forest Products Laboratory demonstrates the applicability of these fire-resistance calculation procedures for TimberStrand® laminated strand lumber (LSL), Parallam® parallel strand lumber (PSL), and Microllam® laminated veneer lumber (LVL). In a report dated February 2000, researcher Robert H. White concluded, “One-dimensional charring tests of structural composite lumber products including LVLs, PSLs, and LSLs confirmed that charring of these products in the standard fire-endurance test may be considered comparable with solid wood. Such results support the use of the fire-resistance calculation procedures for solid wood to estimate the ratings of composite lumber products.” (Charring Rate of Composite Timber Products, Proceedings of Wood & Fire Safety: 4th International Scientific Conference.)

Product or Wood SpeciesChar Rates(6)

Inches/Hour mm/Min.TimberStrand® LSL(1) 1.7 0.72

Parallam® PSL(1) 1.5 0.64Microllam® LVL(2) 1.4 0.59

TJI® Joist Performance Plus® Web(3) 1.5 0.62OSB(4) 1.5 0.64

Douglas Fir(5) 1.4 0.59Southern Pine(5) 1.8 0.76

Hemlock (Eastern)(5) 1.4 0.59Sitka Spruce(5) 1.5 0.63

Ponderosa Pine(5) 1.7 0.72

(1) Southwest Research Institute, Project No. 01-1046-001.(2) TRADA International, Project No. RRESF91013.(3) Weyerhaeuser Research & Development Report No. 991-1763.(4) Forest Products Laboratory Report FPL-RP-610. Fire Resistance of Engineered

Wood Rim Board Products, May 2003.(5) Wood Handbook USDA, FS Agriculture Handbook 72, rev. 1999, p. 17–11.(6) Nominal char rates, Bη.

The NFPA 550 Guide to the Fire Safety Concepts Tree states that fires can be managed by suppressing the fire (with sprinklers) or controlling the fire by construction (with membrane protection). Fire safety goals such as life safety, property

protection, and continuity of building operations help determine the strategy to manage fire.

Char rate and flame spread classes reveal that iLevel engineered lumber, OSB, and sawn lumber have equivalent fire performance characteristics because iLevel

products are composed of approximately 95% wood fiber.

Char Rate Comparison

Page 4: WALL SOLUTIONS ROOF SOLUTIONS FIRE FACTS GUIDE · Floors, roofs, and walls can be assembled in three ways: 1. Unrated, unprotected assemblies: Structural members are exposed (without

iLevel Trus Joist® Fire Facts Guide 1500 July 20084

FIRE RESISTANCE

Standards for Determining Fire Resistance of Construction and Building MaterialsIn the United States and Canada, the model building codes rely on test standards to establish the relative fire resistance of different wall and floor or roof/ceiling assemblies. These standards include the test methods ASTM E119, ANSI/UL 263, CAN/ULC-S101, and NFPA 251. All of these tests specify the standardized fire time-temperature curve shown here.

This time-temperature curve provides a standardized exposure for evaluating structural components and systems. This standardized exposure has been used for many decades by agencies such as ASTM, UL, and ULC, and the building codes that are used to assess fire resistance. While a tested one-hour assembly may or may not contain a real-world fire for a full hour, it does provide a relative measure of fire resistance.

With this in mind, the following floor/ceiling, roof/ceiling, and wall assemblies have been evaluated using this standard, and therefore can be specified for the resistance ratings shown.

2000

1750

1500

1250

1000

750

500

250

0

Time-Temperature Curve (Used by ASTM, UL, ULC, and NFPA)

Flame SpreadA flame spread test is used to evaluate the surface flammability of a material or product. Test standards are defined by ASTM E84 in the United States and CAN/ULC-S102 in Canada. The Flame Spread Index is used by the model building codes to classify building content and surface finishes. A low rating means slow flame spread.

Flame Spread Comparison

Product or Wood Species Flame Spread Index (Range)

Flame Spread Class

TimberStrand® LSL(1) 140(6) III or CParallam® PSL(2) 50(6) II or BMicrollam® LVL(3) 50(6) II or B

OSB(4) 131(7) (74–172) III or CDouglas Fir(5) (70–100) III or C

Southern Pine(5) (130–195) III or CHemlock (Western)(5) (60–75) II or B

Sitka Spruce(5) 100(6) III or CPonderosa Pine(5) (105–230) III or C

(1) PFS Corporation, Report No. WR-94105.(2) Warnock Hersey, Fire Laboratory Division, Report No. 3521.(3) Warnock Hersey, Fire Laboratory Division, Report No. 3815.(4) Design for Code Acceptance 1, American Wood Council.(5) Wood Handbook USDA, FS Agriculture Handbook 72, rev. 1999, p. 17–3.(6) Single test.(7) Average of 14 tests.

Char rate and flame spread classes reveal that iLevel engineered lumber, OSB, and sawn lumber have equivalent fire performance characteristics because iLevel

products are composed of approximately 95% wood fiber.

Page 5: WALL SOLUTIONS ROOF SOLUTIONS FIRE FACTS GUIDE · Floors, roofs, and walls can be assembled in three ways: 1. Unrated, unprotected assemblies: Structural members are exposed (without

iLevel Trus Joist® Fire Facts Guide 1500 July 2008 5

1

8 7 6 5 4 3

2

FLOOR/CEILING, ROOF/CEILING ASSEMBLIES

1. 48/24 tongue-and-groove, span-rated sheathing (Exposure 1)

2. Two layers ½" thick Type C gypsum board or two layers 5⁄8" thick Type X gypsum board

3. TJI® joist or open-web truss

Optional when used with resilient channels (not shown): Minimum 3½" thick glass fiber insulation or non-combustible insulation that is rated R-30 or less.

Note: Resilient channels may be installed between the joists and gypsum board if improved STC and IIC sound ratings are desired.

1. Double wood floor

2. TJI® joist with minimum 1½" flange depth or open-web truss

3. Fixture protection

4. 24" x 48" recessed light fixture

5. Cold-rolled channels

6. 12" air diffuser

7. Minimum 1" thick (4pcf minimum) mineral wool blankets

8. 5⁄8" thick acoustical panels, 24" x 24" or 24" x 48", supported by an approved exposed fire-rated suspension system

One-Hour AssemblyAssembly ACAN/ULC-S101 and ASTM E119; ICC ES reports ESR-1153 and ESR-1774. See reports for additional construction information.

1. 48/24 tongue-and-groove, span-rated sheathing (Exposure 1)

2. TJI® joist or open-web truss

3. 5⁄8" thick 24" x 24" ceiling panels

4. Fixture protection

5. ½" thick Type C gypsum board or 5⁄8" thick Type X gypsum board

6. 24" x 48" recessed light fixture

7. 6" x 12" opening for return air

8. 12" diameter diffuser opening

9. Steel suspension grid

One-Hour AssemblyAssembly BCAN/ULC-S101 and ASTM E119; ICC ES reports ESR-1153 and ESR-1774. See reports for additional construction information.

One-Hour AssemblyAssembly CCAN/ULC-S101 and ASTM E119; ICC ES reports ESR-1153 and ESR-1774. See reports for additional construction information.

One-Hour AssemblyAssembly DCAN/ULC-S101 and ASTM E119; ICC ES reports ESR-1153 and ESR-1774. See reports for additional construction information.

1

3 2

10" min.

8 5 9 7 6 4 3

2 1

4 3 6 7 4 3

21

6

1. 48/24 tongue-and-groove, span-rated sheathing (Exposure 1)

2. TJI® joist or open-web truss

3. No. 26 gauge galvanized steel furring channel installed perpendicular to joists spaced 24" on-center. Furring channels spaced 1½" from and on each side of wallboard end joints and 24" on-center away from end joints. Channel secured to joists with support clips (item 4) at each joist location. At channel splices, adjacent pieces overlapped 6" and tied with double strand of No. 18 SWG galvanized steel wire at each end of overlap.

4. Simpson Strong-Tie Co. Type CSC support clips to be used to support furring channels at the intersection with each joist. Support clips nailed to side of joist bottom flange with 1½" long No. 11 gauge nails.

5. Stabilizer strap (not shown). 3⁄4" x 6" No. 24 gauge galvanized-steel strap used to prevent rotation of the support clips at wallboard end joints and along walls.

6. Minimum 1" thick (6 pcf minimum) mineral wool blankets

7. ½" thick Type C gypsum board

Lightweight concrete or approved gypsum concrete topping with appropriate sheathing can be

substituted for the decking material shown in any of these assemblies.

12" min.

Page 6: WALL SOLUTIONS ROOF SOLUTIONS FIRE FACTS GUIDE · Floors, roofs, and walls can be assembled in three ways: 1. Unrated, unprotected assemblies: Structural members are exposed (without

iLevel Trus Joist® Fire Facts Guide 1500 July 20086

1

3 4 2 5

FLOOR/CEILING, ROOF/CEILING ASSEMBLIES

1. 48/24 tongue-and-groove, span-rated sheathing (Exposure 1)

2. TJI® joist or open-web truss, 24" on-center maximum

3. Optional glass fiber insulation, unfaced batts, 3½" thick in plenum, supported by stay wires 12" on-center and centered on joist bottom flanges

4. Three layers of 5⁄8" thick Type C gypsum board

5. Resilient channels at 16" on-center located between first and second layers of gypsum board

2 1

4

4

2

5 5

5

3

Typical resilient channel and gypsum board attachment

Two-Hour AssemblyAssembly G CAN/ULC-S101 and ASTM E119; ICC ES reports ESR-1153 and ESR-1774. See reports for additional construction information.

Assembly G is typically used for garage/living unit separation

45-Minute AssemblyDesign TJ/FCA 45-01CAN/ULC-S101 and ASTM E119. As evaluated by Intertek Testing Services in their Directory of Listed Products.

A 45-minute floor/ceiling system is not currently used in the United States

1

34 5

2 1. 48/24 tongue-and-groove, span-rated sheathing (Exposure 1). 40/20 tongue-and-groove, span-rated sheathing (Exposure 1) is permitted with proprietary gypsum as listed in TJ/FCA 45-06.

2. TJI® joist

3. Single layer 5⁄8" thick Type X gypsum board

4. Resilient channels at 16" on-center (optional)

5. Optional when used with resilient channels: Minimum 3½" thick glass fiber insulation or non-combustible insulation that is rated R-30 or less

Note: For concrete topping applications, a single layer of 40/20 span-rated sheathing (Exposure 1) over joists at 24" on-center with 1½" lightweight concrete or 1" of gypsum concrete is an allowed deck alternative. If the joists are spaced no more than 20" on-center, a 3⁄4" thick gypsum concrete topping is permitted.

6

1. 48/24 tongue-and-groove, span-rated sheathing (Exposure 1)

2. 5⁄8" thick Type C gypsum board

3. TJI® joist (with flange size minimum of 1½" thick x 3½" wide)

4. Resilient channel at 16" on-center

5. Minimum 1½" thick (2.5 pcf minimum) mineral wool batts

Typical detail for butt joints perpendicular to framing members

1. Double wood floor or single layer of 48/24 tongue-and-groove span-rated sheathing (Exposure 1)

2. TJI® joist or open-web truss

3. An approved ceiling system that will provide a 40-minute finish rating

1 2

3

One-Hour AssemblyAssembly ECAN/ULC-S101 and ASTM E119; ICC ES reports ESR-1153 and ESR-1774. See reports for additional construction information.

One-Hour AssemblyAssembly F CAN/ULC-S101 and ASTM E119; ICC ES report ESR-1153. See reports for additional construction information.

FLOOR/CEILING ASSEMBLY

Lightweight concrete or approved gypsum concrete topping with appropriate sheathing can be

substituted for the decking material shown in any of these assemblies.

Page 7: WALL SOLUTIONS ROOF SOLUTIONS FIRE FACTS GUIDE · Floors, roofs, and walls can be assembled in three ways: 1. Unrated, unprotected assemblies: Structural members are exposed (without

iLevel Trus Joist® Fire Facts Guide 1500 July 2008 7

CENTER-WALL ASSEMBLIES

1. Bottom chord of roof truss, parallel to wall

2. a) 45-minute-rated wall construction b) One-hour-rated wall construction

3. Unrated floor/ceiling (no ceiling membrane)

4. iLevel® 11⁄8" rim board for depths of 16" or less; 11⁄4" TimberStrand® LSL rim board for depths of 18" and 20"

5. Continuous ½" thick Type X gypsum wallboard, applied to inner side of rim board on one side and fastened with 11⁄4" Type W screws at 12" on-center

2a4

2a

3

1

Two-Story Application: Double bearing wall, with rim board carrying a small portion of roof load applied by bottom chord of truss running parallel to the wall. TJI® joists are either perpendicular or parallel to the wall. Blocking as required for stability.

5

2b4

2b

3

1One-Hour AssemblyCenter-Wall Design 1ACAN/ULC-S101 and ASTM E119.As evaluated by Intertek Testing Services.

45-Minute AssemblyCenter-Wall Design 1ACAN/ULC-S101 and ASTM E119.As evaluated by Intertek Testing Services.

1. Bottom chord of roof truss, parallel to wall

2. One-hour-rated wall construction

3. Unrated or rated gypsum board ceiling, taped and filled

4. iLevel® 11⁄8" rim board for depths of 16" or less; 11⁄4" TimberStrand® LSL rim board for depths of 18" and 20"

One-Hour AssemblyCenter-Wall Design 2ACAN/ULC-S101 and ASTM E119.As evaluated by Intertek Testing Services.

42

2

3

1

Critical gypsum board placement shown in blue

Multi-Story Application: Double bearing wall, with full design load on rim board applied individually to each side of the wall assembly. Blocking as required for stability, both sides of wall.

1. a) 45-minute-rated roof/ceiling assembly b) One-hour-rated roof/ceiling assembly

2. a) 45-minute-rated wall construction b) One-hour-rated wall construction

3. Unrated floor/ceiling (no ceiling membrane)

4. iLevel® 11⁄8" rim board for depths of 16" or less; 11⁄4" TimberStrand® LSL rim board for depths of 18" and 20"

5. Continuous ½" thick conventional gypsum board, applied to both rim boards on occupancy sides and fastened with 11⁄4" Type W screws at 12" on-center

6. Continuous ½" thick Type C or Type X gypsum board, applied to both rim boards on occupancy sides and fastened with 11⁄4" Type W screws at 12" on-center

1b 1b6 2b

32b4

45-Minute AssemblyCenter-Wall Design 3ACAN/ULC-S101 and ASTM E119.As evaluated by Intertek Testing Services.

One-Hour AssemblyCenter-Wall Design 3ACAN/ULC-S101 and ASTM E119.As evaluated by Intertek Testing Services.

1a 1a2a

32a4

5

Page 8: WALL SOLUTIONS ROOF SOLUTIONS FIRE FACTS GUIDE · Floors, roofs, and walls can be assembled in three ways: 1. Unrated, unprotected assemblies: Structural members are exposed (without

iLevel Trus Joist® Fire Facts Guide 1500 July 20088

CENTER-WALL ASSEMBLIES

Critical gypsum board placement shown in blue

1. One-hour-rated floor/ceiling or roof/ceiling assembly

2. a) 45-minute-rated wall construction b) One-hour-rated wall construction

3. a) 45-minute-rated floor/ceiling b) One-hour-rated floor/ceiling

4. iLevel® 11⁄8" rim board for depths of 16" or less; 11⁄4" TimberStrand® LSL rim board for depths of 18" and 20"

5. Continuous ½" thick Type X gypsum board, applied to both rim boards on occupancy sides and fastened with 11⁄4" Type W screws at 12" on-center.

Alternative (not shown): 1½" thick mineral wool batt insulation friction-fit.

1 1

3 4 5 2b

3b2b

1 1

3 4 2a

3a2a

1. One-hour-rated floor/ceiling or roof/ceiling assembly

2. One-hour-rated wall construction

3. One-hour-rated floor/ceiling assembly

4. iLevel® 11⁄8" rim board for depths of 16" or less; 11⁄4" TimberStrand® LSL rim board for depths of 18" and 20"

1 1 4 2

32

Multi-Story Application: Double bearing wall, with full design load on rim board applied individually to each side of the wall assembly. TJI® joists are either perpendicular or parallel to wall. Blocking as required for stability.

One-Hour AssemblyCenter-Wall Design 4ACAN/ULC-S101 and ASTM E119.As evaluated by Intertek Testing Services.

45-Minute AssemblyCenter-Wall Design 4ACAN/ULC-S101 and ASTM E119.As evaluated by Intertek Testing Services.

One-Hour AssemblyCenter-Wall Design 5ACAN/ULC-S101 and ASTM E119.As evaluated by Intertek Testing Services.

1a2a

2a

4

7 5

3 3

1a

1b 1b2b

2b

4

73 3

6

Multi-Story Application: Double bearing wall, with full design load on rim board applied individually to each side of the wall assembly. Blocking as required for stability, both sides of wall.

1. a) 45-minute-rated roof/ceiling assembly b) One-hour-rated roof/ceiling assembly

2. a) 45-minute-rated wall construction b) One-hour-rated wall construction

3. Unrated floor/ceiling (no ceiling membrane)

4. iLevel® 11⁄8" rim board for depths of 16" or less; 11⁄4" TimberStrand® LSL rim board for depths of 18" and 20"

5. Continuous ½" thick conventional gypsum board, applied to both rim boards on occupancy sides and fastened with 11⁄4" Type W screws at 12" on-center

6. Continuous ½" thick Type C or Type X gypsum board, applied to both rim boards on occupancy sides and fastened with 11⁄4" Type W screws at 12" on-center

7. Blocking

45-Minute AssemblyCenter-Wall Design 3BCAN/ULC-S101 and ASTM E119.As evaluated by Intertek Testing Services.

One-Hour AssemblyCenter-Wall Design 3BCAN/ULC-S101 and ASTM E119.As evaluated by Intertek Testing Services.

Page 9: WALL SOLUTIONS ROOF SOLUTIONS FIRE FACTS GUIDE · Floors, roofs, and walls can be assembled in three ways: 1. Unrated, unprotected assemblies: Structural members are exposed (without

iLevel Trus Joist® Fire Facts Guide 1500 July 2008 9

CENTER-WALL ASSEMBLIES

Multi-Story Application: Single bearing wall with full design load on rim board. Staggered 2x4 studs attached to 2x6 plates in bearing wall is also acceptable. TJI® joists are either perpendicular or parallel to the wall. Blocking as required for stability.

Multi-Story Application: Single bearing wall with full design load on rim board. TJI® joists are either perpendicular or parallel to wall with continuous rim. Bracing or blocking as required for stability. This design can also be used for interior walls if 5⁄8" Type X gypsum is installed on the opposite side (not shown).

One-Hour AssemblyCenter-Wall Design 6ACAN/ULC-S101 and ASTM E119.As evaluated by Intertek Testing Services.

One-Hour AssemblyCenter-Wall Design 7ACAN/ULC-S101 and ASTM E119.As evaluated by Intertek Testing Services.

1. 2x4 or 2x6 minimum studs

2. One-hour-rated wall construction

3. Continuous TJI® joist at 24" on-center maximum across the wall

4. Rim board cut to fit snug between joist flanges, toenail to keep in position. iLevel® 11⁄8" rim board for depths of 16" or less;

11⁄4" TimberStrand® LSL rim board for depths of 18" and 20".

5. 45-minute- or one-hour-rated floor/ceiling

6. Web stiffeners each side of TJI® joists and attached to web at rim board. See iLevel literature for placement.

7. Gap: 1/16" maximum between joist flange and web stiffener.

1

2

2

43

7

6

5

1. 2x4 minimum studs

2. 2x6 minimum studs

3. TJI® joists

4. Continuous iLevel® 11⁄8" rim board for depths of 16" or less; Continuous 11⁄4" TimberStrand® LSL rim board for depths of 18" and 20"

5. Continuous 5⁄8" Type X gypsum board applied to rim board on occupancy side and fastened with 1½" Type W screws at 12" on-center (gypsum board may be eliminated if a one-hour-rated floor/ceiling assembly exists)

6. One-hour-rated floor/ceiling system (if required)

7. One-hour-rated wall construction

Not shown: Specific details for gypsum board and cladding on exterior side of the vertical studs.

34

276

1

5

One-Hour Assembly From occupant side

End-Wall Designs 1A and 1BCAN/ULC-S101 and ASTM E119. As evaluated by Intertek Testing Services.

(1B) Joists Parallel to Wall

(1A) Joists Perpendicular to Wall

34

16 7

5

END-WALL ASSEMBLIES

1

2

3

2

45

1. 2x6 minimum studs

2. One-hour-rated wall construction

3. Non-continuous TJI® joist at 24" on-center maximum, abutting to continuous rim board along the wall

4. iLevel® 11⁄8" rim board for depths of 16" or less; 11⁄4" TimberStrand® LSL rim board for depths of 18" and 20"

5. 45-minute- or one-hour-rated floor/ceiling

Critical gypsum board placement shown in blue

Page 10: WALL SOLUTIONS ROOF SOLUTIONS FIRE FACTS GUIDE · Floors, roofs, and walls can be assembled in three ways: 1. Unrated, unprotected assemblies: Structural members are exposed (without

iLevel Trus Joist® Fire Facts Guide 1500 July 200810

END-WALL ASSEMBLIES

Continuous Rim TJI® Blocking

1. TJI® joists

2. Continuous 5⁄8" Type X gypsum board (fastened with 1½" Type W screws at TJI® joist rim)

3. 2x6 minimum studs

4. 2x4 minimum studs

5. One-hour floor/ceiling system (if required)

For Continuous Rim:

6. Continuous TJI® rim joist (single joist allowed if it meets vertical load requirement)

7. Continuous 5⁄8" Type X gypsum board in web area of rim joist, fastened with 1½" Type W screws

For TJI® Blocking:

8. 5⁄8" Type X gypsum board, fastened with 1½" Type W screws, between joists (notch to fit into web area of adjacent joists)

9. TJI® blocking between joists

10. 5⁄8" Type X gypsum board in web area of TJI® blocking, fastened with 1½" Type W screws (extend to fit into web area of adjacent joists)

Not shown: Specific details for gypsum board and cladding on exterior side of the vertical studs.

1 2

6

3

2

4

9

5

2

5

1

10

8

7

Continuous Rim

Joists Perpendicular to Wall

TJI® Blocking

Joists Perpendicular to Wall

1

6

3

2

4

9

5

2

5

1

10

8

7

2

One-Hour Assembly From occupant side. Interior wall. Fire protection on exterior side of joist rim.

End-Wall Design 2ACAN/ULC-S101 and ASTM E119. As evaluated by Intertek Testing Services.

Critical gypsum board placement shown in blue

1. Two layers 5⁄8" thick Type X gypsum board

2. 2x4 minimum studs

3. 2x6 minimum studs

4. TJI® joists

5. iLevel® 11⁄8" rim board for depths of 16" or less 11⁄4" TimberStrand® LSL rim board for depths of 18" and 20"

6. Two layers ½" thick Type X gypsum board fastened with 13⁄4" Type W screws. (One layer 5⁄8" thick Type X gypsum board, fastened with 1½" Type W screws, when floor/ceiling assembly is one-hour rated.)

7. One-hour floor/ceiling assembly (if required)

Not shown: Specific details for gypsum board and cladding on exterior side of the vertical studs.

31

4

7

6

5

2 7

4

1

6

5

(3A) Joists Perpendicular to Wall

(3B) Joists Parallel to Wall

Two-Hour Assembly From occupant side

End-Wall Designs 3A and 3BCAN/ULC-S101 and ASTM E119. As evaluated by Intertek Testing Services.

Multi-Story Application: Single bearing wall with full design load on rim board. TJI® joists are either perpendicular or parallel to wall. Blocking as required for stability. This design can also be used for interior walls if 5⁄8" Type X gypsum is installed on the opposite side (not shown).

Multi-Story Application: Single bearing wall with full design load on rim board. TJI® joists are either perpendicular or parallel to wall with continuous rim. Blocking as required for stability. This design can also be used for interior walls if 5⁄8" Type X gypsum is installed on the opposite side (not shown).

One-Hour Assembly From occupant side. Exterior wall. No fire protection on exterior side of joist rim.

End-Wall Design 2ACAN/ULC-S101 and ASTM E119. As evaluated by Intertek Testing Services.

Page 11: WALL SOLUTIONS ROOF SOLUTIONS FIRE FACTS GUIDE · Floors, roofs, and walls can be assembled in three ways: 1. Unrated, unprotected assemblies: Structural members are exposed (without

iLevel Trus Joist® Fire Facts Guide 1500 July 2008 11

NOTES

Page 12: WALL SOLUTIONS ROOF SOLUTIONS FIRE FACTS GUIDE · Floors, roofs, and walls can be assembled in three ways: 1. Unrated, unprotected assemblies: Structural members are exposed (without

12 iLevel Trus Joist® Fire Facts Guide 1500 July 200812

Q&A

FIRE RATINGSIf a fire-rated assembly has a one-hour rating, does that mean it will last one hour during a real fire?Not necessarily. Every fire is different, so it would be impractical to design a test that fits all possible scenarios. The fire-resistance rating is strictly for comparing alternative materials and assemblies against one another. The one-hour rating represents a 60-minute resistance using the standard time-temperature curve.

How realistic is the comparison between the time -temperature curve developed for standard fire-resistance tests and the conditions in a real fire?Variations in fuel load, ventilation, and ignition source make every fire different. This disparity makes it difficult to produce a time-temperature curve that reflects general fire conditions modeled for fires of similar duration and intensity.

Tests of simulated room fires conducted by the National Bureau of Standards(1) and the Forest Products Laboratory have produced time-temperature curves that differ noticeably from the standard curve shown on page 4. Although the standard time-temperature curve may not match any one real-world fire, it provides a widely accepted standard for evaluating the relative performance of different assemblies.

For further reference to the time-temperature curve test, see Fire Development and Wall Endurance in Sandwich and Wood-Frame Structures, by the USDA, FS, Forest Products Laboratory(2), or Fire Development in Residential Basement Rooms, by the National Bureau of Standards(3).

Can TJI® joist assemblies in both floor and roof applications maintain their fire-endurance rating when holes are cut through the web for plumbing, electrical, or duct work?Yes. Holes of allowed sizes, drilled or cut through the joist webs to accommodate utilities, are considered when fire ratings are granted.

How does insulation affect performance for fire-rated assemblies?Generally, fire resistance is increased if an assembly passes without insulation and then insulation is inserted with an air gap between it and the gypsum board (such as that provided by resilient channels).

Testing by the National Research Council of Canada (NRCC) has shown that, when properly attached, two layers of 1⁄2"-thick Type X gypsum board will provide a minimum one-hour rating regardless of whether insulation is used.

What is the difference between a “finish rating” and an “assembly rating”? A finish rating represents the time required for the structural wood closest to the fire (typically the bottom of a joist) to reach a peak temperature of 325°F above initial temperature, or an average temperature of 250°F above initial temperature. A finish rating is an indication of how effective the ceiling or membrane is at protecting the wood structure. However, it is not intended to be a ceiling or membrane rating. An assembly rating is the fire-endurance rating for the entire assembly or system.

What are the requirements for rim board in wall separations?Wall and roof assemblies are tested for fire endurance using ASTM E119 test protocols, and do not consider the role that rim board plays in wall separations. Requirements for rim board within a rated assembly vary

12

Variations in fuel load, ventilation, and ignition source make every fire different.

Page 13: WALL SOLUTIONS ROOF SOLUTIONS FIRE FACTS GUIDE · Floors, roofs, and walls can be assembled in three ways: 1. Unrated, unprotected assemblies: Structural members are exposed (without

13iLevel Trus Joist® Fire Facts Guide 1500 July 2008 13

Q&A

depending upon the authority having jurisdiction. In some cases, gypsum board may be attached to rim board to meet the rating requirements. The wall assemblies in this guide have been independently evaluated by Intertek Testing Services.

Does this guide include all fire-resistant assemblies evaluated for use with iLevel products?No. Only the most common applications are included in this guide. Additional assemblies and more information on fire testing may be found at:

www.awc.org . . . . . . . . . . . . . . . . . American Forest and Paper Association (See DCA No. 3, Fire Rated Wood Floor and Wall Assemblies)

www.gypsum.org . . . . . . . . . . . . . . Gypsum Association (See Fire Resistance Design Manual, 18th Edition GA-600-2006)

www.intertek-etlsemko.com . . . . Intertek ETL Semko

www.ul.com/fire . . . . . . . . . . . . . . . Underwriters Laboratories, Inc.

iLEvEL PRODUCTSCan Microllam® LvL be substituted for sawn lumber or glue-laminated beams in heavy timber construction or fire-rated assemblies?Yes, with the approval of local building officials. Char-rate tests on Microllam® LVL have determined it to be at least equivalent to any of the sawn lumber species from which it is made. Flame spread tests yield lower flame spread indices for Microllam® LVL than for the source species; however, no specific heavy timber or assembly testing has been conducted using Microllam® LVL. Therefore, local building officials grant individual approval based on char-rate and flame-spread-rate data. In the U.S., Microllam® LVL is specifically approved for heavy timber construction when minimum dimensional requirements are met, while approval in Canada hinges on equal or larger-size substitution in fire-rated assemblies.

Can TimberStrand® LSL be used as a substitute for sawn lumber in fire-rated floor assemblies? Yes. In both Canada and the U.S., TimberStrand® LSL is permitted as a substitute in fire-rated floor assemblies when used in the same or larger

dimensions as sawn lumber.

Can Parallam® PSL be used as a substitute for sawn lumber or glue-laminated timber in heavy timber applications?Yes. All model code agencies in the U.S. and Canada recognize Parallam® PSL as a suitable alternative in heavy timber construction when it meets or exceeds the minimum dimensional requirements. Tests conducted at Underwriters Laboratories Inc., Intertek Testing Services/Warnock Hersey, and Southwest Research Institute indicate that the fire resistance of Parallam® PSL is equivalent to that of sawn lumber or glue-laminated timber.

Can rim board be used as fire blocking?Yes. In the U.S. and Canada, rim board with a minimum net thickness of 1" may be used as fire blocking as an alternative to 2" nominal lumber. Additionally, in the U.S., 11⁄4" TimberStrand® LSL and iLevel® 11⁄8" rim board may be used in lieu of sawn lumber for fire blocking.

TimberStrand® LSL of the same or larger dimension may be used as a substitute for sawn lumber in fire-rated floor assemblies.

Page 14: WALL SOLUTIONS ROOF SOLUTIONS FIRE FACTS GUIDE · Floors, roofs, and walls can be assembled in three ways: 1. Unrated, unprotected assemblies: Structural members are exposed (without

14 iLevel Trus Joist® Fire Facts Guide 1500 July 200814

Q&A

Have iLevel’s fire-rated assemblies changed now that some joist series use a thinner flange?No. The fire-resistance rated assemblies recognized in ICC ES ESR-1153 have not changed. However, three of the assemblies (A, D, and F) require minimum flange sizes that would exclude the use of joists with thinner flanges.

FLAMMABILITYAre the flame spread ratings similar for sawn lumber joists, TJI® joists, and TimberStrand® LSL?Yes. Sawn lumber joists, TJI® joists, TimberStrand® LSL, and other wood-based products (such as plywood and OSB) are all ranked in the Class C flame spread rating category.

Flame spread ratings are approximate ratings of surface flammability, which affects fire propagation rate and available escape time. Model building codes require a low flame-spread rate in critical safety zones such as exit locations. A low index number signifies slower flame spread, whereas a higher number indicates quicker flame spread. Class A (Level I) materials have a Flame Spread Index (FSI) of 0–25, Class B (Level II) materials have an FSI from 26–75 and Class C (Level III) materials (sawn lumber joists, TJI® joists, and TimberStrand® LSL) have an FSI ranging from 76–200.

Flame spread ratings are primarily used to govern building contents and wall finishes. Because sawn lumber joists, TJI® joists, and TimberStrand® LSL are used as structural supports and are typically covered with other materials, this rating does not become an issue.

What about flame spread ratings for Microllam® LvL and Parallam® PSL?The comparison table on page 4 shows that flame spread ratings for Microllam® LVL and Parallam® PSL are equal to or lower than those of equivalent sawn lumber species because of the adhesives used in iLevel engineered wood products. Ignition temperatures of the glues used in these iLevel products are higher than ignition temperatures of sawn wood, and flame spread may be less than in ordinary wood.

Can iLevel engineered lumber products be treated with a fire retardant? Currently, iLevel does not pressure treat their products to achieve fire-retardant-treated status. However, a number of commercially available paint-on or spray-on products can be used to provide a Class A flame spread surface on iLevel products.

SAFETY IN A REAL FIREDo the adhesives used in iLevel® engineered lumber products increase smoke toxicity compared to ordinary wood?No. The leading cause of death in fires is smoke inhalation. Testing shows that there is no significant difference between the smoke toxicity of ordinary wood and that of engineered lumber products of the same species.

Do adhesives contribute to early structural collapse compared to the performance of ordinary wood?No. Adhesives do not trigger an early structural collapse. The wood material—not the adhesive—controls fire resistance. See the question “What about flame spread ratings for Microllam® LVL and Parallam® PSL?” above.

Page 15: WALL SOLUTIONS ROOF SOLUTIONS FIRE FACTS GUIDE · Floors, roofs, and walls can be assembled in three ways: 1. Unrated, unprotected assemblies: Structural members are exposed (without

15iLevel Trus Joist® Fire Facts Guide 1500 July 2008 15

Q&A

Do adhesives promote the spread of fire? No. For strand products, such as TimberStrand® LSL, Parallam® PSL, and Structurwood® OSB, standardized flame spread tests show that the progression of flame along the product surface does not change within the current classification (class C) due to the presence of the adhesive. The adhesive is a small percentage of the overall product and the impact on fire spread is negligible. The adhesive used to assemble other products (such as TJI® joist flanges or Microllam® LVL) is located inside the product, away from the surface, and does not impact flame spread.

Where can I find additional information on fire-resistant testing and fire-safe construction?See the following websites for more information:www.cwc.ca . . . . . . . . . . . . . . Canadian Wood Councilwww.iccsafe.org . . . . . . . . . . . International Code Councilwww.icc-es.org . . . . . . . . . . . . International Code Council Evaluation Servicewww.nfpa.org . . . . . . . . . . . . . National Fire Protection Associationwww.firesafehome.org . . . . . Residential Fire Safety Institute (RFSI)

(1) National Bureau of Standards is now known as the National Institute of Standards and Technology.

(2) USDA, FS, Forest Products Laboratory, Research Paper FPL 364, March 1980.(3) National Bureau of Standards, NBSIR, 80-2120.

Page 16: WALL SOLUTIONS ROOF SOLUTIONS FIRE FACTS GUIDE · Floors, roofs, and walls can be assembled in three ways: 1. Unrated, unprotected assemblies: Structural members are exposed (without

Weyerhaeuser, iLevel®, Microllam®, Parallam®, Performance Plus®, Silent Floor®, Structurwood®, TimberStrand®, TJI®, and Trus Joist® are registered trademarks of Weyerhaeuser. © 2008 Weyerhaeuser Company. All rights reserved. Printed in the USA.

WALL SOLUTIONS FLOOR SOLUTIONSROOF SOLUTIONS

July 2008Reorder 1500

CONTACT US OUR GUARANTEE

This document supersedes all previous versions. If this is more than one year old, contact your dealer or iLevel rep.NW

WE CAN HELP YOU BUILD SMARTER.At iLevel, our goal is to help you build solid and durable homes by providing high-quality residential building

products and unparalleled technical and field support.

Floors and Roofs: Start with the best framing components in the industry: our iLevel® Trus Joist® Silent Floor® joists;

TimberStrand® LSL rim board; and TimberStrand® LSL, Microllam® LVL, and Parallam® PSL headers and beams. Pull

them all together with our durable iLevel® Structurwood® roof sheathing and self-gapping Structurwood Edge® or

Structurwood Edge Gold® floor panels.

Walls: Get the best value out of your framing package—use TimberStrand® LSL studs for tall walls, kitchens,

and bathrooms, and our traditional, solid-sawn lumber everywhere else. Cut down installation time by using

TimberStrand® LSL headers for doors and windows, and our Structurwood® wall sheathing with its handy two-way

nail lines.

Software Solutions: If you are a design professional or lumber dealer, iLevel offers a full array of software packages

to help you specify individual framing members, create cut lists, manage inventories—even help you design

whole-house framing solutions. Contact your iLevel representative to find out how to get the software you need.

Technical Support: Need technical help? iLevel has one of the largest networks of engineers and sales

representatives in the business. Call us for help, and a skilled member from our team of experts will contact you

within one business day to evaluate and help solve your structural frame problems—GUARANTEED.

1.888.iLevel8 (1.888.453.8358)

www.iLevel.com [email protected]

2910 East Amity Road Boise, ID 83716 208.364.3600

P.O. Box 8449 Boise, ID 83707-2449