VSWR Steps

download VSWR Steps

of 7

Transcript of VSWR Steps

  • 7/29/2019 VSWR Steps

    1/7

    VSWR TEST

    Training & Consultancy Unit

    Tariq Ismail

    JUNE 25, 2010

    This document helps understand the operation of Anritsu Site Master, calibrating a site master, setting GSM900 and DCS 1800 configurations, how to locate and detect a fault. VSWR helps in removing reflection fromfeeder cables, which is very important as TX/RX calibration would be of no effect if high reflections arefound in the table

  • 7/29/2019 VSWR Steps

    2/7

    2VSWR TEST

    ANRITSU Site Master S3310

    Operation Manual

  • 7/29/2019 VSWR Steps

    3/7

    3VSWR TEST

    Front Panel

    STEPS TO

    PERFORM

    VSWRTEST

    Turn on Site Master by pressing ON/OFF

    START

    CAL

    SAVE

    SETUP

    MODEFREQ-

    DIST

    AMPLITU

    DEDE

    RECAL

    SETUP

    ESCAPE/CLE

    AR

    ENTE

    R

    MARKE

    R

    Save

    Display RECAL

    Display

    RF Out

    Port

    ON

  • 7/29/2019 VSWR Steps

    4/7

    4VSWR TEST

    Press Enter to Continue

    Press RECALL SETUP and select GSM900 or DCS 1800 accordingly

    Move to Level 3 and lock all DRIs of the sector in which sweep test (VSWR) is

    required

    Procedure to Lock a DRI (assuming DRI 1 0)

    Login to BTS through MCUF/H2SC controller card

    Type the command chg_l

    Type level 2 password and press enter

    Type level 3 password and press enter

    Type the command lock dri 1 0

    When radio status LED of the DRI starts blinking, the DRI is locked

    After locking the sector ,remove feeder cable from the respective DRIs DUP

    and connect it with RF OUT port of site master

    Wait for 10 seconds and graphical display will appear showing the reflection

    throughout cable length.

    Press MARKER, select M1 and then press EDIT, now u can move the markerthrough the cable length and check reflections at any desired distance

    To save a current reflection, press SAVE DISPLAY, save by site name and fault

    location for easy access in future

    To view a previous display, press RECALL DISPLAY

    Calibrating the site Master (OSL)

    Site master will show calibration OFF while configuring to GSM 900 or DCS 1800, a

    dummy load with open, short and load labeled is used for the site master calibration

  • 7/29/2019 VSWR Steps

    5/7

    5VSWR TEST

    Press START CAL

    Connect OPEN to the RF OUT port, it will show success

    Now calibrate by connecting SHORT

    Finally connect LOAD with RF out port of site master, connect according to

    the instruction displayed by screen

    GSM 900 & DCS 1800 settings

    Press RECALL SETUP, list of already configured setups (If any) will appear

    0 H OSL SWR 0.0 - 140.0 m1 H OSL SWR 0.0 - 145.0 m

    234 H OSL SWR 1710.00 1880.00

    MHZ5 H OSL SWR 880.00 960.00 MHZ678

    Steps for GSM 900 configuration

    We need to set up three parameters; Frequency, Distance and Amplitude

    Press MODE

    Select FREQ-SWR and press ENTER

    Press F1 and enter lower limit

    Example F1 = 830.00 MHZ

    Press F2 and enter upper limit

    Example F2= 1000.00 MHZ (Now frequencies are set)

    Press MODE again

    Select DTF-SWR (DTF stands for distance to fault) press ENTER

    Press D1 to enter start distance

  • 7/29/2019 VSWR Steps

    6/7

    6VSWR TEST

    D1= 0.0 m

    Press D2 to enter end distance (estimate the length of the cable, it

    should not be less)

    Example D2= 140 m (Now distance is set)

    To set up the amplitude, Press AMPLITUDE

    Select TOP and enter limit 1.5

    Now select BOTTOM and enter 1 (amplitude cannot be lesser than 1)

    Finally, to save the settings, press SAVE SETUP

    Check your saved settings for GSM 900 by RECALL SETUP

    Steps for DCS 1800 configuration

    We need to set up three parameters; Frequency, Distance and Amplitude

    Press MODE

    Select FREQ-SWR and press ENTER

    Press F1 and enter lower limit

    Example F1 = 1700.00 MHZ

    Press F2 and enter upper limit

    Example F2= 1900.00 MHZ (Now frequencies are set)

    Press MODE again

    Select DTF-SWR (DTF stands for distance to fault) press ENTER

    Press D1 to enter start distance

    D1= 0.0 m

    Press D2 to enter end distance (estimate the length of the cable, it

    should not be less)

    Example D2= 140 m (Now distance is set)

  • 7/29/2019 VSWR Steps

    7/7

    7VSWR TEST

    To set up the amplitude, Press AMPLITUDE

    Select TOP and enter limit 1.5

    Now select BOTTOM and enter 1 (amplitude cannot be lesser than 1)

    Finally, to save the settings, press SAVE SETUP

    Check your saved settings for GSM 1800 by RECALL SETUP

    VSWR Test is a must before any DRI calibration, it there are reflections in

    cable, calibrating that DRI will not be effective