    soluionorfluidtechnology

    vs seRies

    flow meAsuRementTECHNOLOGY

  • 8/3/2019 Vse Serievs en 0510

    2/22

    2

    vsi-high definition pReAmplifieR The VSI High Definition Preamplifier supplies digitalsignals witha higher resolution of the measuredvalue.Theresolutioncanbeprogrammedbetween4and64

    angle steps and it enables a frequency multiplicationupto factor 16.TheK-factor oftheflowmeter can beincreaseduptofactor64.Themaximumfrequencyatfull

    flowcanbe26kHz.

    eX-types Intrinsicallysafemodels,withapprovalcodel1G

    EExiallCT4-T6,aresuppliedforapplicationsinpotenti-allyexplosion-hazardousareas.VSEdeliversthesetypeswith isolation switch amplifier models MK 13 P Ex

    Ex0/21VDC/K15.

    vs positive displAcement flow meteRs

    vs flow meteRVSpositivedisplacementflowmetersarevolumeratemeasuringsensorsbasedonthemeshinggearprinciple

    and are designed for use with liquids. Two preciselymatchedgearwheelsareenclosedin averyaccuratelymachined housing. Gear rotation is sensed by a non-contacting signal pick-up system. Each tooth produces

    oneimpulse.

    The space between the gear teeth, when fully

    enclosedonbothsidesbythehousing,constitutesmeasu-ringchambers.Fluidflowcausesthegearstorotateandtheincomingflowisseparatedintodiscretevolumeswithin

    thesechambersi.e.thevolumeofliquidpassingthroughtheunitwillcauserotationofthegearsbyexactlyone

    toothpitch.

    This volume is known as the Volume/Impulse (Vm

    )

    andisstatedincc/Imp.Itisusedtodefinethesizeofaflowmeter.

    eXplAnAtions of pReAmplifieR of signAl

    picK-up systemThenon-contactpick-upsensorsconsistoftwodifferential

    magnetoresistors,whicharecircumferentiallyoffsetfromoneanotherby1/4ofatoothpitch.Thesignalsofbothpick-up sensors are digitised with two signal amplifiers

    and amplified via followed shortcircuit proof push-pull

    outputstages.Thesquarewaveoutputsignalsarebidirectionalandmay

    besimplyprocessedbyanyexternalelectronics,plccontrolor computer. The processing of the 90 phase anglebetween signals enables recognition of flow direction

    andimpulserateconversionwithafactorof1,2and4.

    Thesignalfrequencyisproportionaltothemomentary

    flowrate(volumerate)dependentontheparticularflowmetersize.Thefrequencyrangeextendsfrom02000Hz.Thepreamplifierisprotectedagainstreversepolarity

    andincorrectconnection.Formediumtemperaturesbet-ween-40Cand120C(-22Fand248F)theunitismounteddirectlyontheflowmetercover.

    sensoR systems foR eXtended

    tempeRAtuRe RAnge For liquid temperatures up to 210C (410F) aspecialpickupsystemisavailable.

    vs flow meteR selection

    Fortrouble-freeandsafeoperationoftheflowmeters

    thecorrectselectionoftypeandsizeisdecisive.Dueto

    thegreatnumberofdifferentapplicationsandflowmeter

    versions,thetechnicaldataintheVSE-cataloguesareof

    generalcharacter. Certain characteristic of thedevices

    dependontype,sizeandmeasuringrangeaswellason

    themediumtobemeasured.Forexactflowmeterselection

    pleasecontactVSE.

  • 8/3/2019 Vse Serievs en 0510

    3/22

    3

    BlocK diAgRAm

    output signAls of pReAmplifieR

    flow meteR vs 0,02... vs 4 flow meteR vs 10

    Gear rotation of one tooth pitch

    One impulse

    Volume / impulse in cm 3 / Imp

    Channel1

    Channel2

    Channeloffsetby1/4oftoothpitch(90)

    Impulsemark/spaceratio(adjust.atpreamplier)

    Fl owi ndi re ct ion1 F lowi n di rec ti on2

    Upp

    + Volts

    Channel 1

    0 Volts

    Channel 2

    brown

    white

    blue

    black

    ProcessorUnit

    Signal Amplifiers Push-pulloutputstages

    Potential equalization

    * voltAge RAnges Supplyvoltages: U

    v=10...28VDC

    Impulsevoltages: Upp

    =Uv1V

    * voltAge RAnges Supplyvoltages: U

    v=10...28VDC

    Impulsevoltages: Upp

    =Uv1V

    Channel1

    Channel2

    Channeloffsetby1/4oftoothpitch(90)

    Impulsemark/spaceratio(adjust.atpreamplier)

    Flowdirec tion1 Flowdirec tion2

    Gear rotation of one tooth pitch

    3 impulse pro volume (10 cm3 ) of one tooth pitch

    Volume / impulse in cm3 / Imp (10/3 cm3 =V

    m)

  • 8/3/2019 Vse Serievs en 0510

    4/22

    4

    ApplicAtionsAll liquids that can be pumped and have known

    lubrication properties can be measured, for example:petrol, paraffin, kerosene, diesel, Skydrol, mineral oils,hydraulicoilsincludingfireresistantfluids,inks,dyesand

    paints, greases, polyurethane, polyol and isocyanates,Araldite,glues,pastesandcreams,resins,waxes...andmanyothers.

    RAnges of ApplicAtions in

    the Automotive industRy

    Brakingsystemteststands

    Fuelconsumptionmeasurement

    Polyurethane foams for steering wheels, fascia, seats etc.

    Paintsprayingsystems

    Steeringsystems

    Batching and filling of motor oils, brake fluids, anti- freeze,corrosionpreventatives,waxesetc.

    Adhesivecoatingsforwindscreens,headlights,engine housingsetc.

    hydRAulics

    Volumeandflowratemeasurement

    Leakageandrupturemonitoring

    Cylinderspeedandpositionmeasurement

    Positioningandstepcontrol

    Measurement,controlandregulationofflowratesand volumes

    Teststandsforpumps,motors,valves,proportionalsand servo-valves

    Synchronisedmulti-cylindermonitoring

    Fillingandadditiveblending

    dyes And pAints

    Paintsprayingsystems

    Batchingandfilling

    Volume,flowrateandconsumption

    Monitoringofmixingratios

    plAstics technology

    Mixing,mouldingandbatchingsystemsforsingleand multicomponentfluidplastics

    Consumptionmeasurementofe.g.: Epoxyadhesives and potting compounds (resins and hardeners) for transformers, coils, relays, condensers,

    armatures,initiators,auto-electronics

    Measuring,controlandregulationofsinglecomponents andmixingratios

    Siliconpottingcompounds

    Polyurethanefoams(polyolandisocyanate)forsteering wheels,seals,shoes,soles,surfboards,furniture,com- putercasings,isolationetc.

    hotadhesive

    chemicAl industRy

    Flowrateandvolumemeasurementinprocessplantand plantsystems

    Blending and filling chemical products such as liquid plasticsadhesives,resins,hardeners,potting,compounds,

    solvents,fuels,foamesplasticisers,dyesand paints, oils and synthetic products etc. application in laboratories and manufacturing plants (in normal and explosion-

    hazardousareas)

    Control and regulation of single components, mixing ratiosandconsumptionofvariouscomponents

    Leakagemeasurementandleakagemonitoringonplant

    Measurement, indication and logging of data for productqualityassurance

    speciAl designs on Request

    The issue of this catalogue invalidates all specifica-tions in earlier publications. Changes and deviationsare reserved by VSE. VSE will not accept liability

    for printing errors. Reproduction, including excerpts,is only permitted with written permission by VSE.Revision:05/2010

    RAnges of ApplicAtions

  • 8/3/2019 Vse Serievs en 0510

    5/22

    5

    Ara 0.3%ofmeasuredvalueatviscosity>20cSt(

  • 8/3/2019 Vse Serievs en 0510

    6/22

    6

    flow Response cuRves

    flowr

    esistance

    p

    flowrateQ

    flowr

    esistance

    p

    flowr

    esistance

    p

    flowr

    esistance

    p

    flowr

    esistance

    p

    flowr

    esistance

    p

    flowr

    esistance

    p

    flowr

    esistance

    p

    vs 0.1 vs 0.2

    vs 1vs 0.4

    vs 4vs 2

    vs 0.02 vs 0.04

    flowrateQ

    flowrateQ flowrateQ

    flowrateQ flowrateQ

    flowrateQ flowrateQ

  • 8/3/2019 Vse Serievs en 0510

    7/22

    7

    r

    *GG=CastIronEN-GJS-400-15(EN1563)

    *E =StainlessSteel1.4305 Dimensionsarespecifiedinmm

    cAst iRon veRsionHousingcurvemillcutted

    cAst iRon veRsion

    connection dRAwingViewX

    Flowmeter

    Subplate

    Flowmeter

    Subplate

    side poRts Bottom poRts

    vs flow meteR dimensions

    to and

    andtostAinless steel veRsion

    connection dRAwingHousingnotmillcutted

    ViewX

    Grounding

    Centre bores

    Grounding

    Plug direction for

    Plug direction for

    Centre bores

    sz

    vs / vsiA B c d e g h K l m n o-r gg*

    k

    e*

    k

    0.02 100 80 91 M6 12 9 114 58 70 40 20 11 x2 2.8 3.4

    0.04 100 80 91.5 M6 11.5 9 114.5 58.5 70 40 20 11 x2 2.8 3.4

    0.1 100 80 94 M6 9 9 117 61 70 40 20 11 x2 2.8 3.4

    0.2 100 80 93.5 M6 9.5 9 116.5 60.5 70 40 20 11 x2 3.0 3.7

    0.4 115 90 96.5 M8 11.5 16 119.5 63.5 80 38 34 17.96x2.62 4.0 5.0

    1 130 100 101 M8 12 16 124 68 84 72 34 17.96x2.62 5.3 6.8

    2 130 100 118 M8 15 16 141 85 84 72 34 17.96x2.62 6.7 8.4

    4 180 140 143 M12 20 30 166 110 46 95 45 36.17x2.62 14.7 18.4

    w

  • 8/3/2019 Vse Serievs en 0510

    8/22

    8

    side poRts Bottom poRts *

    CastIron/APG.S.. ./. StainlessSteel/APE.S.. ./. CastIron/APG.U... /. StainlessSteel/APE.U.. ./.

    AffiliAted

    siZe

    vs / vsi

    g pipe thReAd

    clAssificAtion

    g f h e

    0.02/0.04

    0.1/0.2

    G1/4 35 20 26

    0.02/0.04

    0.1/0.2

    G3/8 35 23 30

    0.02/0.04

    0.1/0.2

    0.4/1/2

    G1/2

    G1/2

    35

    35

    28

    28

    38

    46

    0.4/1/2 G3/4 40 33 52

    1/2 G1 55 41 55

    4 G11/4 70 51 60

    4 G11/2 AP..U=70 56 72

    4 G11/2 AP..S=80 56 72

    *Bothbottomports(G)forsizeAPG4UandAPE4Uhaveadisplacementof90totheshowndrawings.

    sz d w

    vs / vsi Ap A B c d l m k

    0.02 / 0.04

    0.1 / 0.2

    AP.02 80 90 40 70 100 M6/12 1.8

    0.4 AP.04 90 100 38 80 115 M8/15 2.7

    1 / 2 AP.1 100 110 72 84 130 M8/15 3.6

    4 APG4

    APG4UG

    APE.4

    120

    140

    140

    130

    120

    100

    120

    100

    110

    100

    110

    180

    M8/15

    M8/15

    M8/15

    7.4

    7.4

    12

    Ap suBplAte dimensions

    1

    2

    2

    1 OnlyforAPG.U.../.;APE.U.../.OnlyforAPE.S.../.;APE.U.../.

    Specialdesignsonrequest

    AffiliAted

    siZe

    vs / vsi

    g pipe thReAd

    clAssificAtion

    g f h e 11

    sz d w

    vs / vsi Ap A B c d l m k22

  • 8/3/2019 Vse Serievs en 0510

    9/22

    9

    vs 10 flow meteR

    sz f ra / gpm K-far

    i. /

    i. / ga.

    VS10 1.5...525 0.3963...138.69 300 1135.63

    Ara 0.3%ofmeasuredvalueatviscosity>20cSt(

  • 8/3/2019 Vse Serievs en 0510

    10/22

    10

    flow Response cuRves

    dimensions

    suBplAte dimensions

    flowr

    esistance

    p

    Dimensionsarespecifiedinmm

    Dimensionsarespecifiedinmm

    APG10SGON/1 APG10SWON/1

    flowrateQ

  • 8/3/2019 Vse Serievs en 0510

    11/22

    11

    vse flow meteRs in eX-design / the BARRieR AmplifieR

    I

    I

    Potential equalization system!

    3

    4

    Explosion-hazardous area Non-explosion-hazardous area

    5

    6

    7

    8

    pnp

    pnp

    +

    -power

    Signal (1. Channel)

    Inv. signal (1. Channel)

    Ub2+

    GND2 (0V; Ub2-)

    Flow meter

    Isolation switching amplifier: 1. ChannelEvaluation unit

    3

    4

    5

    6

    7

    8

    pnp

    pnp

    +

    -power

    Isolation switching amplifier: 2. Channel

    Signal (2. Channel)

    Inv. signal (2. Channel)

    Ub1+

    GND1 (0V; Ub1-)MK 13-P-Ex0/24VDC/K15

    MK 13-P-Ex0/24VDC/K15

    Potential equalization system!

    B

    B+-

    4

    2

    1

    2. Channel+- 3

    +-

    1

    2

    1

    1. Channel+- 2

    ifrequired

    the BARRieR AmplifieR mK 13-p-eX 0 / 24

    vdc / K15ThebarrieramplifierMK13-P-Ex0/24VDC/K15enablesa galvanic isolated transmission of binary switchingstatus. It has an intrinsically safe control circuit and is

    certifiedaccordingtoII(1)GD(EExial)IIC.There is a galvanic separation from the control circuitto the output circuit and to the power supply. For the

    transmission of two channels, two barrier amplifiers ofthis version are necessary. The control circuit can be

    monitoredconcerningwirebreakingandshortcircuit(themonitoringcanbeswitchedoffviaawirejumper).Anerrorinthecontrolcircuitstopsthesignaloutputbutisnotdisplayedasanerrormessage.Twoplus-switching

    shortcircuitprooftransistoroutputs(PNP-outputs)displaythedigitalsignalofachannelantivalently.

    f r vse ab, b, puR, Barrr afir

    t vs****32 q1* / * ; 4 x 0,34 2 t mK 13-p-ex 0 / 24 vdc / K15

    BVS05ATEXE071X PUR PTB06ATEX2025

    ll1GEExiallCT4-T6 ll(1)G[EExia]llC

    Ui

    = 18,5V R =0,053/m Uo=9,9V

    Ii

    = 24mA L =0,85H/m (x) Io

    =22mA

    Pi

    =100mW CA-A

    =55pF/m (x) Po

    =54mW

    Ri

    = 0 CA-S

    =105pF/m (x)

    Li

    = 0 [(x)=measuredat1000Hz]

    Ci

    = 0,27F c B

    Lo/mH 1 5 10 2 10 20

    Co/F 1,5 0,75 0,65 5 3,5 3

    trar a t4 t5 t6

    ambienttemperature -20CTamb

    95C -20CTamb

    70C -20CTamb

    55C

    liquidtemperature -20CTMed

    100C -20CTMed

    75C -20CTMed

    60C

    vse flow meteRs in eX-designThe VSE flow meters of the VS-series in Ex-designare approved for applications in potentially explosion-

    hazardousareasandarealwaysoperatedinconjunctionwithoneortwobarrieramplifiers.Theyhavebluemar-kingsandofferthenecessaryEx-protectionsecurity.The

    typeplateshowsthenecessarydescriptionaccordingtoDINEN50014,thetypekeyandthesafety-relatedandelectricdata. VSE can supply the flow meters with the

    barrieramplifierstypeMK13-P-Ex0/24VDC/K15.

  • 8/3/2019 Vse Serievs en 0510

    12/22

    12

    option foR stAinless-steel

    flow meteRs vs 0,04 vs 4Thepick-upsystemconsistsofoneortwosensorunits,whicharescrewedintothecoveroftheVSflowmeterandofadownstreamswitchedamplifier.Thisamplifieris

    connectedwiththeflowmeterbymeansofatemperatureresistantcableandhastobeinstalledoutsidethehightemperaturearea,wheretheambienttemperatureshouldnotexceed50C(122F).

    Dependingontheamplifierversion,thedigitalsignalsare output as PNP or NPN switching signals. The fol-

    lowing pictures show the respective connection of theelectronicreadout:

    For long cable lengths and high input impedanceof the readout it is recommended to use shieldedcablesandapull-down(PNP-signal)orapull-up(NPN-

    signal)resistors.

    connection: pnp-switching

    connection: npn-switching

    picK-up system foR high tempeRAtuRe RAnges

    Flowmeter Amplif ier Electronicreadout

    MeasuringControlling

    PNP-Signal plus switching

    NPN-Signal

    minus switching

  • 8/3/2019 Vse Serievs en 0510

    13/22

    13

    technicAl dAtA / flow meteR dimensions

    m trar 40C...210C

    nbr k- 1or2pick-ups

    pk- Magnetoresistive

    era c PGcablefitting

    ia-pr IP64

    s va Ub

    =10...30V DC+/10-%

    crr c Ib =ca.15mA(idlemotion,withoutload)

    sa o pnp HighSign:Us=U

    b1V,l

    s=25mAmax.

    sa o npn LowSign:Us=0V,l

    s=25mAmax.

    era c 4-poleroundplugM12

    max. Ab trar 50C

    pr-a IP64

    p- Rr 4.7...10K

    p- Rr 4.7...10K

    technicAl dAtA: sensoR unit

    technicAl dAtA: AmplifieR

    Centre bores

    Amplifier

    Cable lenght

    r

    flow meteR dimensions view X

    sz A d e g K l m n p o-rw

    k

    VS0.04* 100 M6 11.5 9 58.5 70 40 20 22 11 x2 3.5

    VS0.1 100 M6 9 9 61 70 40 20 22 11 x2 3.3

    VS0.2 100 M6 9.5 9 60.5 70 40 20 22 11 x2 3.6

    VS0.4 115 M8 11.5 16 63.5 80 38 34 22 17.96 x2.62 4.9

    VS1 130 M8 12 16 68 84 72 34 22 17.96 x2.62 6.7

    VS2 130 M8 15 16 85 84 72 34 22 17.96 x2.62 8.3

    VS4 180 M12 20 30 110 46 95 45 12 36.17 x2.62 18.3

    *Attention:*0.04withone(1)channelonly

  • 8/3/2019 Vse Serievs en 0510

    14/22

    14

    type Key flow meteRs vs

    type Key

    eXAmple

  • 8/3/2019 Vse Serievs en 0510

    15/22

    15

    suBplAtes Ap

    suBplAtes Ap

    eXAmple

  • 8/3/2019 Vse Serievs en 0510

    16/22

    16

    flow meteRs with high definition pReAmplifieR

    flow meteRs with high definition flow RAteThepreamplifiersofthestandardversionforflowmetersofthe

    VSproductlineoutputonepulsepertooth-gapvolumeVZ,which

    corresponds to the volume measurement Vm

    (Vm

    =VZ/pulse).

    This occurs in two channels, so that a maximum resolution of

    1/4VZfortheevaluationofallflankscanbeattained.Ahigher

    resolutionisnotpossiblewiththesepreamplifiers.Asaveryhighresolutionisnecessaryforpreciseandexactflow

    measurements,thevolumemeasurementVm

    mustberesolvedevenmore than with conventional preamplifiers. VSE has thereforedevelopedthepreamplifierwithinterpolation,withwhichaselec-

    tableresolutionofupto64flanks(16pulses)perperiodcanbeattained.ThismeansthatyoucanresolvethevolumemeasurementV

    mwiththispreamplifiertoamaximumof1/64V

    m.Fortheevalua-

    tion,thismeansthatapartvolumeof1/64Vm

    frompulseflankto

    pulseflank(forquadrupleevaluationorflankcount)ismeasured,orafullsignalpulseiscountedaspartvolumeof1/16V

    m(pulse

    count)(interpolationVm/16).

    ThisindividuallyprogrammedhighresolutionenablesyoutosetthevolumemeasurementV

    moptimallyforeachpro-

    videdcaseofapplication.Furthermore,newapplicationscanbeavailedwiththehigherresolution

    Measuring,controllingandregulatinginlower

    flowrangesMeasuring,controllingandregulatinginzeroflowMeasuring,controllingandregulatinginbothflow

    directionsMeasuring,controlling,dosingandfillingofsmall

    volumes

    Flowmeterswithinterpolationelectronics(VSI)outputtwodigitalsignalswithprogrammablehighresolutionthatare

    phase-offsetat 90.In additionto the signal emission,

    a zero signal emissionis provided, whichemitsa zerosignalateachfullyregisteredvolumemeasurementV

    m.

    signAl emission of the pReAmplifieR with

    inteRpolAtionThe gure shows the resolution of the volume measurementV

    mwithaninterpolationfactorof8.Thisresolveseachvolume

    measurementintoeightindividualpartvolumes.Apulseonthesignaloutputofchannel1orchannel2thushasavalueof

    Vm* = Vm/8 = 1/8 Vm per pulse. In double evaluation(ank evaluation of one channel) this results in a value of1/2 V

    m* = V

    m /16 = 1/16 V

    m and for quadruple evaluati-

    on(ankevaluationofbothchannels)theresultisavalueof

    1/4Vm*=V

    m/32=1/32V

    mperank.Evaluationelectronics

    canrecognizeowdirectionfromsignalsoffsetat90.ThepreamplifieroftheVSIproductlinehasaprogrammedinterpolation factor (IPF) with which you can program

    new,differentresolutions.Henceyoucanprogramare-

    solutionof4to64angularsteps(seefigure4)pervolumemeasurementV

    m.Thefrequencymultiplicationf*isbet-

    ween1and16(seetable).

  • 8/3/2019 Vse Serievs en 0510

    17/22

    17

    inteRpolAtion fActoR And Resolution

    ira

    ar

    i/v max. r

    (evaluation of signalanks)

    R v*

    (volume measurementV

    m*) [ml]

    max. r

    (a r)

    fr ax*

    1 1 4(quadrupling) Vm/4 90 fmaxx1

    2 2 8 Vm/8 45 fmaxx2

    3 3 12 Vm/12 30 fmaxx3

    4 4 16 Vm/16 22.5 fmaxx4

    5 5 20 Vm/20 18 fmaxx5

    8 8 32 Vm/32 11.25 fmaxx8

    10 10 40 Vm/40 9 fmaxx10

    12 12 48 Vm/48 7.5 fmaxx12

    16 16 64 Vm/64 5.625 fmaxx16

    Column1: programmableinterpolation factor IPF (pro- grammingisdoneinthefactory)

    Column2:PulsespervolumemeasurementVm

    Column3:maximumresolutionofthesignalflanks.The signal flankschannels1and2areevaluated.

    Column4: Volume measurementVm

    * resulting from the maximum resolutionof the signal flanks.Column5:maximumresolutioninangledegreesatreso-

    lutionofsignalflanks.Column6:maximum frequency f

    max* at maximum flow

    Qmax

    andprogrammedinterpolationfactorIPF

    InpracticethemaximumflowQmaxoftheflowmeterisseldomrunsothat

    alowerfrequencycanbecalculated.Themaximumfrequencyisthencalculatedaccordingtothefollowingformula:

    f

    max*=

    (Qmax

    )*IPFformula1

    Vm

    fmax*

    Maximum frequency of the flow meter signals

    Qmax

    Maximumflowattainedinthecaseofapplication describedhereIPF Programmedinterpolation factor

    Vm

    Volumemeasurementoftheflowmeter

    exa: Flow meter VSI 1/10 max. flow rate of the systematmaximumcapacityQ

    max = 40 l/min = 666.667 ml/sec; IPF = 10;

    Vm

    =1ml/pulse;fmax*

    =6666.67Hz=6.66667kHz

    Atmax. flowmax*

    = 40l/min, the flow meter VSI 1/10 outputsafrequencyof

    fmax*

    = 6666.67Hz.

  • 8/3/2019 Vse Serievs en 0510

    18/22

    18

    type Key flow meteRs vsi

    type Key

    eXAmple

  • 8/3/2019 Vse Serievs en 0510

    19/22

    19

    electRonic displAys with AnAlogue output

    Flowmetertypeselectablebymenu

    Flowmeterdirectionindicator16Bit-analogueoutput 010V

    020mA 0/420mA2limitvalueoutputs

    SemiconductorPC-Interface RS 232 or RS 485Apowersupplyforflowsensoris

    integrated 24 Volt DC/100 mA

    Flowdirectionindicationwithswit- chingoutput(0V/5V)

    2optocouplerlimitvalueoutputs, limit value are individually pro- grammable

    Analogue output with flow rate direction dependent voltage-/ current-polarityisavaible

    0()10V 0()20mA 4 20mA

    Apowersupplyforflowsensoris integrated24VDC/50mA

    Flow rate- or volumedisplay pro-

    grammable, with linearizer func- tion12Bit-analogueoutput

    010V 020mA 420mA

    2limitvalue-relayoutputsPC-InterfaceRS232Apowersupplyforflowsensoris

    integrated12Volt/100mA

    flow meAsuRement dpZ-imp foR 1- oR 2-chAnnelflow sensoRFlowmetertypeselectableby menu16bit-analogueoutput 010V 020mA

    0/420mA2limitvalueoutputs

    SemiconductorPC-InterfaceRS232oderRS485Apowersupplyforflowsensoris integrated24VoltDC/100mA

    univeRsAl meAsuRing instRument

    vfm 320 foR dynAmic pRocess meAsuRe-

    ments And closed loop contRolsFlowrate,volumeandratiomeasurementsaswellas measurementandcontrolof volume-shots ormass-

    shotsin2-componentmixingsystemsSignalprocessingof2flowsensorswith2-channel

    signaloutputs2independentdynamicanalogueoutputswith16Bit digital-analogueconverterD/A-converter:

  • 8/3/2019 Vse Serievs en 0510

    20/22

    20

    electRonic displAys without AnAlogue output

    volumen-pResetcounteRAnd BAtch-counteR gel 103

    foR 2-oR 1-chAnnel flow

    sensoRDisplay values for actual volume valueand2volumepresetvalues

    will be displayed simultaneously2limitedvaluerelayandtransistor outputs,1transistoroutputforbatch

    presetcontrolPhase discriminator for 2-channel flow rate sensor with single,

    double or quadruplevolume im-

    pulse edge evalution programm- able

    Apowersupplyforflowsensoris integrated24VDC10%,max. 60mA

    gel 103

    instRuments foR impulse conditioning

    Converteroutputsignalforopera- tionwith1-channelflowsensor

    0...10V 0...20mA 4...20mAConverteroutputsignalwithflow

    direction polarity for operation with2-channelflowsensor 0...10V

    0...20mAEvaluation of flow direction via digital output signal possible if a

    2-channelflowsensorisconnectedProportionalto flowfrequency a digital output frequency signal

    with multiplier factoris adjustable

    fRequency-/AnAlogueconveRteR digfu 1

    For example: for chart recorder withimpulseinput,forward-/reverse- counter, computer, PC- and PLC

    controlsAvailableoutputvoltages: TTL5V,8 V,12V,CMOS15V

    Powersupply/currentconsumption: 10... 30 VDC, 20 mA without flowsensor

    Inverted and non inverted output signal forbothchannelsintegrated among other things for connec-

    tionondifferentialcountinputsto achieve a distortion free signal transmission over long cable dis-

    tances

    signAl conveRteR pgw-1

    foR 2- oR 1- chAnnel

    flow sensoRs to conveRt

    flow sensoR output

    signAls into otheRvoltAge levels

    Economicalinterfaceswithgalva- nic isolation between intrinsically safe and nonintrinsically safe cir-

    cuitsMustbeinstalledinthesafeareaAre used to limit the electrical

    power into an intrinsically safe circuitin sucha waythatneither sparks nor thermal effects (hot

    surfaces) can cause an ignitionConnection diagram and exact orderno.seepage11.

    BARRieR AmplifieRmK-13

    20

  • 8/3/2019 Vse Serievs en 0510

    21/22

    21

    AccessoRies / customeR specific solutions

    Inhouse calibrations from0.002 l/min ... 600 l/min, tra-ceable toa DKD normal. We are

    pleased to provide you with loanunitsforthetimeofrepairorcalibra-tion.Repairandcalibrationalsoof

    externalbrandsaswellaselectro-nicdisplays.

    Customerspecificsolutionscanberealizedforpricesinlinewithmarket

    requirementsintheshortesttime.Wedevelop your solutions in allcurrentmaterialssuchassteel,stainlesssteel,

    titanium and aluminium as well asbronzematerials.

    Whetherforinstallioninvehicles

    orinclimaticexposuretestcabinets;wehaveasolutionforalmosteverymeasuring application. High relia-

    bility, lowspace requirements andhighestmeasurementaccuracy,alsofordifficultmediaoraggressiveat-

    mospheresdistinguishourproducts.

    Dyes,paints,(hot-)adhesivesorepoxy or PUR-materials also withfillers can be reliably measured.

    Pressuresupto700barandtempe-raturesupto210Careincludedinourstandardproductrange.

    customeR specific pRocess contRol AutomoBile industRy

    Connectionblocksalsoheatable,

    sandwich plates with integratedballvalvesandheatingjacketsforall current flow meters. Additionalmeasuringconnectionsforpressure

    andtemperaturecanbesuppliedfromstock.

    AccessoRies

    RepAiR / cAliBRAtion seRvice

  • 8/3/2019 Vse Serievs en 0510

    22/22

    VSEVolumentechnikGmbH VSEVolumentechnikGmbHHnnestrae49 Postfach/P.O.Box122958809Neuenrade/Germany 58804Neuenrade/Germany

    www.p

    lakart.d

    e

    woRldwide seRvice / pRoducts

    woRldwide seRvice

    quAlified Advice thRough

    longstAnding coopeRAtion

    pARtneRspersonalcompetentefficient

    pRoductsPrecisiongearflowmetersforgeneral industrialapplications

    Stainlesssteelgearflowmetersforspecial applications

    Turbineflowmeters

    Standardisedandindividualelectronicreadouts

    Electronicdevicesforspecialsolutionsinmeasurement,

    controlandregulationtechnology

    Repairandcalibrationservice