Page 1: Voltage input specification digital peak holder CSD-819C-31€¦ · Be sure to read this instruction manual before use. 1. Installation place In this instruction manual, the connection

Voltage input specification digital peak holder

CSD-819C-31

EN294-1250-D

Page 2: Voltage input specification digital peak holder CSD-819C-31€¦ · Be sure to read this instruction manual before use. 1. Installation place In this instruction manual, the connection
Page 3: Voltage input specification digital peak holder CSD-819C-31€¦ · Be sure to read this instruction manual before use. 1. Installation place In this instruction manual, the connection

I

Forwards

Thank you very much for your purchasing Minebea’s Digital Peak Holder CSD−819C−31.

This manual explains installation procedures and connecting method and also operatingmethod for the Digital Peak Holder CSD−819C with the optional voltage input function.

When you will use this instrument as the voltage input specifications, make use of it

properly after reading through the manual carefully.

Be sure to deliver the manual to the end user. Moreover, the end user should keep themanual at hand after reading it over.

This manual is intended for the technical experts to read.

●The contents of the manual may subject to change for improvement without notice.

Page 4: Voltage input specification digital peak holder CSD-819C-31€¦ · Be sure to read this instruction manual before use. 1. Installation place In this instruction manual, the connection

II

Marks and arrangements used in this manual

The following marks are attached to the explanation on the matters that indicate “Don’t do

this.”, “Take care.” and “For reference”.

Be sure to read these items where these marks are attached.

Warning ● Warning may cause injury or accident that may harm to the operator.

Don’t do these things described here.

● Caution during operation and working.

Be sure to read the item to prevent malfunction.

Mark during operation.

● Press the switch.

Page 5: Voltage input specification digital peak holder CSD-819C-31€¦ · Be sure to read this instruction manual before use. 1. Installation place In this instruction manual, the connection

III

For safe operation

Be sure to read this instruction manual before use.

1. Installation place

In this instruction manual, the connection method and the calibration method in the

optional voltage input specification of CSD−819C are explained.Please see the CSD−819C instruction manual about other main body functions and a basic

method of handling and notes.

・ The instruction manual of CSD−819C(DRW NO.EN294−1240)

Page 6: Voltage input specification digital peak holder CSD-819C-31€¦ · Be sure to read this instruction manual before use. 1. Installation place In this instruction manual, the connection

IV

History of revision

Date Instruction Manual No. Details of revised point

Oct. 2005 DRW.NO. EN294−1250 First Version ROM Ver. 1.000 or later

Feb. 2010DRW.NO. EN294−1250−A

Due to ECN NO.FN10−02026− Change −Front cover’s logo is changed.

Oct. 2010 DRW.NO. EN294−1250−BDue to ECN NO.FN10−02140− Change −Minebea logo is changed.

May 2012 DRW.NO. EN294−1250−CDue to ECN NO.FN10−02140−D− Change −Minebea logo is changed.

Sep 2013 DRW.NO. EN294−1250−DDue to ECN NO.FN13−02133− Correction −Correction of Outline dimensionsminebea logo is changed.

Page 7: Voltage input specification digital peak holder CSD-819C-31€¦ · Be sure to read this instruction manual before use. 1. Installation place In this instruction manual, the connection

INDEX

Forwards Ⅰ. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Marks and arrangements used in this manual Ⅱ. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .For safe operation Ⅲ. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1. Installation place Ⅲ. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

History of revision Ⅳ. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1. General 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1−1. Features 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2. Name and function of each point 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2−1. Front panel 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2−2. Rear panel 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3. Connecting method 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3−1. Layout of the terminal boards 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3−2. Note on connection 6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3−3. Connection 7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3−3−1. Connection for voltage input 7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4. Calibration procedures 10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4−1. Preparations 10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4−2. Calibration procedures 10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4−2−1. Calibration method to register the input voltage value

at the time of full scale display after setting the input voltage to 0 V. 11.4−2−2. Calibration procedure to register by the reading the input voltage value

in the condition of 0 V and in the condition of inputting the voltageequivalent to the value at the full scale individually 16. . . . . . . . . . . . . . . .

4−2−3. Zero fine adjustment 22. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4−2−4. Span fine adjustment 24. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4−2−5. Calibration procedure to apply registration again for zero point only 26.4−2−6. Compensation of symmetric property

(Fine adjustment of minus side span) 28. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4−3. Monitor mode 30. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5. Function mode 32. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5−1. Setting method for function mode 32. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5−2. Function of function data 34. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6. Trouble shooting 41. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6−1. Execute trouble shooting 42. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6−2. Error display 51. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

7. Specifications 52. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

7−1. Specifications for analog section 52. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

7−2. Specifications for digital section 52. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

7−3. Front panel sheet key function 52. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

7−4. External control function 53. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

7−5. Comparator function 53. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

7−6. Open collector output signal 54. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

7−7. Various kinds of functions 54. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

7−8. General specifications 54. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

7−9. Standard specifications at the shipment 55. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

7−10. Accessories 55. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 8: Voltage input specification digital peak holder CSD-819C-31€¦ · Be sure to read this instruction manual before use. 1. Installation place In this instruction manual, the connection

7−11. Options 55. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7−11−1. Current output 55. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7−11−2. BCD output 55. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7−11−3. RS−232C interface 56. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7−11−4. RS−422/485 interface 56. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

7−12. Outline dimensions 57. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

8. Warranty 58. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

8−1. Warranty 58. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

8−2. Repair 58. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

9. Appendix 59. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

9−1. Setting table for functions 59. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 9: Voltage input specification digital peak holder CSD-819C-31€¦ · Be sure to read this instruction manual before use. 1. Installation place In this instruction manual, the connection

1

1.General

1−1. Features

Main features for CSD−819C−31 are as follows :

(1)Voltage input function

(2)This instrument can connect with the pressure sensor, etc., with voltage output (0 to 5 V or 0

to 10 V), when the external power supply as the sensor’s power supply is prepared at user’s

side.

Page 10: Voltage input specification digital peak holder CSD-819C-31€¦ · Be sure to read this instruction manual before use. 1. Installation place In this instruction manual, the connection

2

2.Name and function of each point

2−1. Front panel

② ③

1 Main display section

In the measurement mode, it displays the calculation result against the input voltage.

In the various kinds of the calibration mode, it displays the conditions.

2 Comparison value selection display panel

It displays the selection number(S0~ S4) of the comparative value.

3 Comparison value setting display panel

It displays the comparative value selected in the item②.

In the various kinds of the setting mode, it displays the conditions.

4 Judgement display section(S0~S4)

It displays the comparative results(S0~ S4) by the comparator function.

5 Condition display section

SEL.1、SEL.2 Lights on when the short−circuit is made between SEL.1, SEL.2 and

COM.1 of external control input.

HOLD Lights on when the short−circuit is made between HOLD and COM.1 of

external control input.

CHECK Lights on when CHECK is ON by pressing key.

PEAK Lights on when any peak mode is selected.

MEAS. Lights on when any peak mode measurement is proceeded.

END Lights on when any peak mode measurement is completed.

6 key

Used when shifting to the Function mode.

7 key

Executes zero set. (One−touched zero adjustment)

Page 11: Voltage input specification digital peak holder CSD-819C-31€¦ · Be sure to read this instruction manual before use. 1. Installation place In this instruction manual, the connection

3

8 key

Used when the changing mode of S0, S1, S2, S3 and S4 for the comparison value selecting

number is called, and used for the numeric carrying−over at the time of various kinds of

setting.

9 key

Used for the changeover of comparison value selecting display, and the numeric increment at

the time of various kind of setting.

10 key

Used for the changeover of peak and track.

11 key

Used for reset of hold value.

12 key

Used for registering set values at the time of various kinds of settings.

13 key

It will not use in this voltage input unit.

14 Position of pasting the Unit seal

As necessity requires, paste the Unit seal attached.

Page 12: Voltage input specification digital peak holder CSD-819C-31€¦ · Be sure to read this instruction manual before use. 1. Installation place In this instruction manual, the connection

4

2−2. Rear panel

1 Terminal block 1

Connects with external control input, open collector output, various kinds of strain gage

applied transducer such as load cell and analog output.

2 Terminal block 2

Connects with AC power supply and a grounding wire.

3 Installing space for options

Whichever one can be installed from the optional BCD−OUT, RS−232C and RS−422/485.When there is no option, the cover is attached instead.

4 Protective ground terminal

Connect the grounding wire when the instrument suits to CE conformity standard.Don’t connect except the grounding wire.

Page 13: Voltage input specification digital peak holder CSD-819C-31€¦ · Be sure to read this instruction manual before use. 1. Installation place In this instruction manual, the connection

5

3.Connecting method

3−1. Layout of the terminal blocks

There are 2 pieces of terminal block and M4 thread, one has 21 points of terminals and the otherhas 3 points of terminals.Layout of terminal blocks and thread are shown in the following figure.:

1 Terminal block 1 (21P)

TerminalNos. Descriptions Applications Terminal

Nos. Descriptions Applications

1 A No use 11 RESET

2 B Voltage input (−) 12 SEL.1 External control3 C No use 13 SEL.2

External controlinput

4 D Voltage input (+) 14 COM.1

5 E Shield 15 END

6 A−OUT+Analog output

16 S0

7 A−OUT-Analog output

17 S1

8 ZERO 18 S2 Open collector

9 HOLD External controli

19 S3

poutput

10 PEAK/TRACK

input20 S4

21 COM.2

2 Terminal block 2 (3P)

Name Application

ACPower supply

ACPower supply

F.G. Frame ground(Functional ground)

3 Protective ground terminal (M4 thread)

Name Application

Protective ground

● The COM.1(Terminal No.14) and COM.2(Terminal No.21) are isolated.

● Don’t connect A(Terminal No.1) with C(Terminal No.3).

Page 14: Voltage input specification digital peak holder CSD-819C-31€¦ · Be sure to read this instruction manual before use. 1. Installation place In this instruction manual, the connection

6

3−2. Note on connection

Warning ● In case of connection with the instrument, keep strictly to the following items. Ifneglected, it may cause an unexpected failure or a damage to the instrument.

・ Be sure to set the power supply to OFF, when the connection will be made.

・ Since the terminal blocks at rear side of the instrument is made of resin, take care not todrop it down or not to apply strong impact.

・ Recommended torque to tighten the terminal screws for terminal block should be asfollows:

Terminal block Torque to tighten the terminal screws

Terminal block 1 0.6 N・m

Terminal block 2 1.4 N・m

Protective groundterminal block

1.4 N・m

・ The suitable crimp type terminal lugs for the terminal block are as follows:

Terminal block Width of crimptype terminal lugs Suitable crimp type terminal lugs

Terminal block 1 6.2 mm or less 1.25−3 or Y type 1.25−3.5

Terminal block 2 9.0 mm or less 1.25−4, 2−4 or Y type 1.25−4, 2−4

Protective groundterminal block

・ Connecting cable with the instrument should be away from the noise source such as powersupply line and/or I/O line for control and so on as far as possible.

・ Conduit wiring should be the type of exclusive one, and avoid using with another linetogether.

・ All of the connections should be executed securely by referring to the Instruction manualfor the instrument.

Page 15: Voltage input specification digital peak holder CSD-819C-31€¦ · Be sure to read this instruction manual before use. 1. Installation place In this instruction manual, the connection

7

3−3. Connection

3−3−1. Connection for voltage input

This instrument can connect with the usual voltage output source and the pressure sensor, and

so on., with voltage output (0~5 V or 0~10 V). Here, we will describe the example of

connections with the usual voltage output source and the pressure transmitters.

● Please use the shielded cable for the connection with voltage input terminal, andconnect the shield cable with E terminal(Terminal No.5) of this instrument. If notconnected, it may cause the malfunction by the influence of the exogenous noise etc.

● The supply power supply for the sensor is not built into this unit.Please supply the power supply suitable for the specification of the sensor from theoutside.

1 Connection of voltage output source and CSD−819C

Shield

Voltage outputsource

● When this instrument suits with the CE conformity standard, please connect theshielded wire with F.G. terminal (Terminal block 2 Terminal No.3).

Page 16: Voltage input specification digital peak holder CSD-819C-31€¦ · Be sure to read this instruction manual before use. 1. Installation place In this instruction manual, the connection

8

● Please use the shielded cable for the connection with voltage input terminal, andconnect the shield cable with E terminal(Terminal No.5) of this instrument. If notconnected, it may cause the malfunction by the influence of the exogenous noise etc.

● The supply power supply for the sensor is not built into this unit.Please supply the power supply suitable for the specification of the sensor from theoutside.

2 Connection with NS series pressure transmitter(4 wires method cable type) and CSD−819C

+ -External powersupply DC24 V(DC18 V to 28 V)

(The wiring color : for Minebea’s standard cable.)

YEL(Shield)

GRN

BLU

WHT

RED

● When this instrument suits with the CE conformity standard, please connect theshielded wire with F.G. terminal (Terminal block 2 Terminal No.3).

Page 17: Voltage input specification digital peak holder CSD-819C-31€¦ · Be sure to read this instruction manual before use. 1. Installation place In this instruction manual, the connection

9

● Please use the shielded cable for the connection with voltage input terminal, andconnect the shield cable with E terminal(Terminal No.5) of this instrument. If notconnected, it may cause the malfunction by the influence of the exogenous noise etc.

● The supply power supply for the sensor is not built into this unit.Please supply the power supply suitable for the specification of the sensor from theoutside.

3 Connection with NS series pressure transmitter(3 wires method cable type) and CSD−819C

+ -

External powersupply DC24 V(DC18 V to 28 V)

(The wiring color : for Minebea’s standard cable.)

YEL(Shield)

GRN

WHT

RED

● When this instrument suits with the CE conformity standard, please connect theshielded wire with F.G. terminal (Terminal block 2 Terminal No.3).

Page 18: Voltage input specification digital peak holder CSD-819C-31€¦ · Be sure to read this instruction manual before use. 1. Installation place In this instruction manual, the connection

10

4.Calibration procedures

Warning ● Before using the new instrument or after exchanging the strain gage appliedtransducer with a new one, be sure to make calibration.If calibration is not made, correct measured results may not be obtained, or it maycause malfunction to the instrument and it may damage the peripheral equipment.Moreover, even if calibration has made, there may occur the similar case as abovewhen the result is not correct. So make precise calibration again.

● The calibration for the instrument and “Display value at the time of minimum analogoutput”(F−21) and “Display value at the time of maximum analog output” (F−22) arenot interlocked. In due course, make check on the setting for F−21 and F−22 securely.If neglected, correct outputs may not be obtained, or it may cause malfunction to theinstrument and it may damage the peripheral equipment.

4−1. Preparations

According to the Chapter 3. Connecting method, connect the instrument and the signal wires input

the voltage properly, then supply the power.

4−2. Calibration procedures

The display calibration procedures against the voltage input for this instrument are as follows:

1 Calibration method to register the input voltage value at the time of full scale display after

setting the input voltage to 0 V.

2 Calibration procedure to register by the reading the input voltage value in the condition of 0 V

and in the condition of inputting the voltage equivalent to the value at the full scale

individually.

3 Fine adjustment on Zero

4 Fine adjustment on Span

5 Calibration procedures to apply registration again for zero point only.

6 Compensation of symmetric property(Fine adjustment of minus side span)

● The accuracy of calibration obtained from① is 1/1 000 or so. If the accuracy morethan 1/1 000 is required, make calibration of② type.

In the following paragraphs, we will describe each calibration procedure by showing theexamples with load cell applied.

Page 19: Voltage input specification digital peak holder CSD-819C-31€¦ · Be sure to read this instruction manual before use. 1. Installation place In this instruction manual, the connection

11

4−2−1. Calibration method to register the input voltage value at the time of full scale display after

setting the input voltage to 0 V.

Warning ● Before using a new instrument, or when the input voltage specifications is changed, orexchange the pressure transmitter for a new one, be sure to make the calibration. Ifcalibration shall not be made, correct measured results may not be obtained nor itmay cause malfunction in the instrument and there may exist damage to theperipheral equipment.Besides, even though the calibration has been made, there may occur the similar casewhen the result is not correct, so make calibration again.

● During the calibration is executing, be sure to make cancellation (Execution of F−98)for compensated data on zero set

● When the changeover target of the calibration data is set to the changeover byexternal control input(Setting of F−80: “00001” or “00011”), execute the calibrationafter the changeover of the calibration data changed by the external controloutput(SEL.1 and SEL.2).

● During calibration procedures, press the key in case of interrupting thecalibration is required. The calibration data will be kept as they are before enteringthe calibration and then returns to the Measurement mode.

● Every time the key is pressed with the setting display section of “FUNC”, the

display will change as the following arrow marks. However, every time the key ispressed, the display will change as the reverse direction of the following arrow marks.“FUNC”→“CCAL”→“LCAL”→“ZERO”→“SPAN”→“TARE”→“CHEK”→“MONT”→“VCAL”→“VADJ”→“SYMM”→“FUNC”→“CCAL”→・・・・・(Hereinafter, it will repeat.)

Procedures

1

Press the key for approx. one second.The setting display section shows “FUNC”.The main display section continuously shows thepresent value equivalent to the current inputvoltage.

2

Press the key once.The setting display section shows “CCAL”.

Page 20: Voltage input specification digital peak holder CSD-819C-31€¦ · Be sure to read this instruction manual before use. 1. Installation place In this instruction manual, the connection

12

Procedures

3

Press the key.“CCAL” mode can be entered, then the maindisplay section shows “SCAL”.

4

Press the key.The main display section shows “D−01”.When the calibration has completed already, theset value of minimum scale registered at thattime will be displayed.Set the minimum scale with the right keys.Setting value for the minimum scale are 4 (four)kinds as follows:1, 2, 5, 10

key :Set value increment key

5

Press the key.The main display section shows “DISP”.

Page 21: Voltage input specification digital peak holder CSD-819C-31€¦ · Be sure to read this instruction manual before use. 1. Installation place In this instruction manual, the connection

13

Procedures

Press the key.The main display section shows “2000”, and theminimum display digit flashes on and off.When the calibration has completed already, themaximum display value registered at that time isdisplayed.

6

By the setting of minimum scale, theminimum display digit that flashes on andoff is as follows:The minimum scale 1, 2, 5 100 digitThe minimum scale 10 101 digit

Set the maximum display value with the rightkeys. Setting range for the maximum displayvalue is as follows:In order to make effective use of the performance,set within the following ranges.

key :Set value carry key

key :Set value increment key

key :Set value initialization key

Setting range for themaximum display value

100~10 000

200~20 000

500~50 000

1 000~99 990

The minimum scale

1

2

5

10

7

Press the key.The main display section shows ”S V”.

Page 22: Voltage input specification digital peak holder CSD-819C-31€¦ · Be sure to read this instruction manual before use. 1. Installation place In this instruction manual, the connection

14

Procedures

8

Press the key.The main display section shows “01.000”, andthe digit of 100 flashes on and off.In case that calibration has completed already,the registered input voltage value at that timewill be displayed.Set the input voltage value with the right keys,corresponding to the maximum display value setin step 6.

Setting range for the input voltage value isfrom 1.000 V to 10.000 V.

key :Set value carry key

By pressing the key continuously,increment can be provided continuously.

key :Set value carry key

key :Set value increment key

key :Set value initialization key

9

Press the key.The main display section shows “ZERO”.Here, set the input voltage to 0 V.If you cannot set the input voltage to 0 V, removethe wiring of input voltage and make theshort−circuit between B(Terminal No.2) andD(Terminal No.4). In this case, as for the zeropoint at the calibration, “0 V” in this unitbecomes a standard.

Page 23: Voltage input specification digital peak holder CSD-819C-31€¦ · Be sure to read this instruction manual before use. 1. Installation place In this instruction manual, the connection

15

Procedures

Press the key.The main display section shows “ZERO” withlighting display on and off, then zero adjustmentcan be started.

10

Warning :At the same time, take care notto cause the fluctuation in input voltage.When any fluctuation in input voltage isapplied, there will be possibilities that zeropoint is unstable, and precise reading ofzero will not be obtained.

After completed, the main display sectionbecomes “END”.However, when the input voltage is not enteredwithin the range from-0.5 V to 0.5 V, the errorcode shown in the right figure will show forabout 2 seconds, then main display section shows“ZERO” and return to step 9.

Error code

TE−L :Zero point -OVERTE−H :Zero point +OVER

Error code

Press the key.After “CCAL” mode is over, the main displaysection shows the display value corresponding tothe present input voltage

11

the present input voltage.When the connection between B(Terminal No.2)and D(Terminal No.4) is short−circuited, returnthe wiring for the input voltage as before.

Page 24: Voltage input specification digital peak holder CSD-819C-31€¦ · Be sure to read this instruction manual before use. 1. Installation place In this instruction manual, the connection

16

4−2−2. Calibration procedure to register by the reading the input voltage value in the

condition of 0 V and in the condition of inputting the voltage equivalent to the value at

the full scale individually.

(1)Procedure by key operation

Warning ● Before using a new instrument, or when the voltage input specifications is changed, orexchange the pressure transmitter for a new one, be sure to make the calibration. Ifcalibration shall not be made, correct measured results may not be obtained nor itmay cause malfunction in the instrument and there may exist damage to theperipheral equipment.Besides, even though the calibration has been made, there may occur the similar casewhen the result is not correct, so make calibration again.

● During the calibration is executing, be sure to make cancellation (Execution of F−98)for compensated data on zero set

● When the changeover target of the calibration data is set to the changeover byexternal control input(Setting of F−80: “00001” or “00011”), execute the calibrationafter the changeover of the calibration data changed by the external controloutput(SEL.1 and SEL.2).

● During calibration procedures, press the key in case of interrupting thecalibration is required. The calibration data will be kept as they are before enteringthe calibration and then returns to the Measurement mode.

● Every time the key is pressed with the setting display section of “FUNC”, the

display changes as following arrow marks. However, every time the key ispressed, the display changes as reverse direction of the following arrow marks.“FUNC”→“CCAL”→“LCAL”→“ZERO”→“SPAN”→“TARE”→“CHEK”→“MONT”→“VCAL”→“VADJ”→“SYMM”→“FUNC”→“CCAL”→・・・・・(Hereinafter, it will repeat.)

Procedures

1

Press the key for about one secondThe setting display section shows “FUNC”.The main display section continuously shows thevalue corresponding to the present input voltage.

Page 25: Voltage input specification digital peak holder CSD-819C-31€¦ · Be sure to read this instruction manual before use. 1. Installation place In this instruction manual, the connection

17

Procedures

2

Press the key twice.It makes the setting display section proceed as“FUNC”→“CCAL”→“LCAL”.

3

Press the key.“LCAL” mode can be entered, then the maindisplay section shows “SCAL”.

4

Press the key.The main display section shows “D−01”.When the calibration has completed already, theset value of minimum scale which has registeredat that time is displayed.Set the minimum scale with the right keys.Setting values for the minimum scale are (four)kinds as follows:1, 2, 5, 10

key :Set value increment key

5

Press the key.The main display section shows “DISP”.

Page 26: Voltage input specification digital peak holder CSD-819C-31€¦ · Be sure to read this instruction manual before use. 1. Installation place In this instruction manual, the connection

18

Procedures

Press the key.The main display section shows “2000” and theminimum display digit flashes on and off.When the calibration has completed already, themaximum display value which has registered atthat time is displayed.

6

By the setting of minimum scale, theminimum display digit that flashes on andoff is as follows:The minimum scale 1, 2, 5 100 digitThe minimum scale 10 101 digit

Set the maximum display value with the rightkeys. Setting range for the maximum displayvalue is as follows:In order to make effective use of the performance,set within the following ranges.

key :Set value carry key

key :Set value increment key

key :Set value initialization key

Setting range for themaximum display value

100~10 000

200~20 000

500~50 000

1 000~99 990

The minimum scale

1

2

5

10

By pressing the key continuously,increment can be provided continuously.

7

Press the key.The main display section shows “LOAD”.

Page 27: Voltage input specification digital peak holder CSD-819C-31€¦ · Be sure to read this instruction manual before use. 1. Installation place In this instruction manual, the connection

19

Procedures

Press the key.The main display section shows “2000” and theminimum display digit flashes on and off.When the calibration has completed already, themaximum display value which has registered atthat time is displayed.

By the setting of minimum scale the

8

By the setting of minimum scale, theminimum display digit that flashes on andoff is as follows:The minimum scale 1, 2, 5 100 digitThe minimum scale 10 101 digit

Set the display value corresponding to the actualinput voltage with the right keys.The display value corresponding to the inputlt h ld b th di l l th th

key :Set value carry key

key :Set value increment key

key :Set value initialization keyvoltage should be the display less than themaximum display value set in step 6, and shouldbe be the maximum display that can apply on theload cell with the range of (the minimum scale×100)~99 990 as well.

By pressing the key continuously,increment can be provided continuously.

key :Set value initialization key

9

Press the key.The main display section shows “ZERO”.Here, set the input voltage to 0 V.

Page 28: Voltage input specification digital peak holder CSD-819C-31€¦ · Be sure to read this instruction manual before use. 1. Installation place In this instruction manual, the connection

20

Procedures

Press the key.The “ZERO” on main display section flashes onand off, and zero adjustment can be started.

10

Warning :Take care not to apply thefluctuation on the input voltage.If any fluctuation on the voltage is applied,the zero point will not stabilized, in duecourse there is a possibility that correctreading of zero won’t be obtained.

When completed, the display on the main displaysection shows “SPAN”.However, when the input voltage is not enteredthe range of-0.5 V to 0.5 V, the right Errorcode will be shown for about 2 seconds, then thedisplay on the main display section will beshown as “ZERO”, and then the step 9 can beentered.

Error code

TE−L:Zero point -OVERTE−H:Zero point +OVER

Error code

11 Apply the same voltage or the equivalent voltageas set in the step 8.

Page 29: Voltage input specification digital peak holder CSD-819C-31€¦ · Be sure to read this instruction manual before use. 1. Installation place In this instruction manual, the connection

21

Procedures

Press the key.The “SPAN” on the main display section flasheson and off, and span adjustment can be started.

12

Warning :Take care not to apply thefluctuation on the input voltage.If any fluctuation on the voltage is applied,the zero point will not stabilized, in duecourse there is a possibility that correctreading of zero won’t be obtained.

When completed, the display on the main displaysection shows “END”.However, when the voltage corresponding to themaximum display value does not satisfy therange from 1.0 V to 10.0 V, the right Error codewill light up for about 2 seconds, then the displayon the main display section shows“SPAN”, and then returns to the step 10.

Error code

SP−L:Span point-OVERSP−H:Span point+OVER

Error code

13

Press the key.After “LCAL” mode is over, the main displaysection shows the display value corresponding tothe present input voltage.

Page 30: Voltage input specification digital peak holder CSD-819C-31€¦ · Be sure to read this instruction manual before use. 1. Installation place In this instruction manual, the connection

22

4−2−3. Zero fine adjustment

(1)Procedures by key operation

● During zero set is executed and also during effective for Peak ON, Zero fineadjustment mode can’t be entered into. (Displays ER−5.)The Zero fine adjustment can be entered after the cancellation of the Compensateddata at Zero set (Execution of F−98) and set the peak OFF.

● When the changeover target of the calibration data is set to the changeover byexternal control input(Setting of F−80: “00001” or “00011”), execute the calibrationafter the changeover of the calibration data changed by the external controloutput(SEL.1 and SEL.2).

● During the calibration procedure, press the key to interrupt the calibration. Thecalibration data will keep the same condition as it is entered before, then returns tothe Measurement mode.

● When the key is pressed with the setting display section of“FUNC”, the display will change as the following arrow marks indicate at every time

the key is pressed. However, every time the key is pressed, the display will changeas the reverse direction of the following arrow marks.“FUNC”→“CCAL”→“LCAL”→“ZERO”→“SPAN”→“TARE”→“CHEK”→“MONT”→“VCAL”→“VADJ”→“SYMM”→“FUNC”→“CCAL”→・・・・・(Hereinafter, it will repeat.)

Procedures

1

Press the key for about one second.The setting display section shows “FUNC”.The main display continuously shows the displayvalue corresponding to the present input voltage.

2

Press the key three times.It makes display in the main display sectionproceeded as “FUNC”→“CCAL”→“LCAL”→“ZERO”.Here, set input voltage to 0 V.

Page 31: Voltage input specification digital peak holder CSD-819C-31€¦ · Be sure to read this instruction manual before use. 1. Installation place In this instruction manual, the connection

23

Procedures

3

Press the key.Zero fine adjustment mode can be entered, thenthe display on main display section lights on andoff. At the same time, set the present displayvalue to “0” with the right keys.

By pressing the key continuously,increment can be provided continuously.

The variation of display value for one pushof the right key is less than 1 digit ofdisplay. Therefore, a few pushes of thesekeys are required to get the change of 1digit of display value.

key :Zero fine adjustmentdisplay decreasing key

key :Zero fine adjustmentdisplay increasing key

4

Press the key.The indication of the main display section shows“END”.

5

Press the key.After quitting from zero fine adjustment mode,the main display section shows the display valuecorresponding to the present input voltage.

5

Page 32: Voltage input specification digital peak holder CSD-819C-31€¦ · Be sure to read this instruction manual before use. 1. Installation place In this instruction manual, the connection

24

4−2−4. Span fine adjustment

(1)Procedures by key operation

● During zero set is executed and also during effective for Peak ON, Span fineadjustment mode can’t be entered into. (Displays ER−5.)The Zero fine adjustment can be entered after the cancellation of the Compensateddata at Zero set (Execution of F−98) and set the peak OFF.

● When the changeover target of the calibration data is set to the changeover byexternal control input(Setting of F−80: “00001” or “00011”), execute the calibrationafter the changeover of the calibration data changed by the external controloutput(SEL.1 and SEL.2).

● During the calibration procedure, press the key to interrupt the calibration. Thecalibration data will keep the same condition as it is entered before, then returns tothe Measurement mode.

● When the key is pressed with the setting display section of “FUNC”, the displaywill change as the following arrow marks indicate at every time the key is pressed.

However, every time the is pressed, the display will change as the reversedirection of the following arrow marks.“FUNC”→“CCAL”→“LCAL”→“ZERO”→“SPAN”→“TARE”→“CHEK”→“MONT”→“VCAL”→“VADJ”→“SYMM”→“FUNC”→“CCAL”→・・・・・(Hereinafter, it will repeat.)

Procedures

1

Press the key for about one secondThe setting display section shows “FUNC”.The main display value continuously shows thedisplay value corresponding to the present inputvoltage.

2

Press the key four times.It makes the setting display section proceeded as“FUNC”→“CCAL”→“LCAL”→“ZERO”→“SPAN”.Here, input the maximum voltage less than themaximum display value, or equivalent to thedisplay.

Page 33: Voltage input specification digital peak holder CSD-819C-31€¦ · Be sure to read this instruction manual before use. 1. Installation place In this instruction manual, the connection

25

Procedures

3

Press the key.Span fine adjustment mode can be entered, thenthe display on main display section lights on andoff. At the same time, adjust the display valuecorresponding to the present input voltage withthe right keys.

By pressing the key continuously,increment can be provided continuously.

The variation of the display value for onepush of the right key is less than 1 digit ofdisplay. Therefore, a few pushes of thesekeys are required to get the change of 1digit of display value.

key :Span fine adjustmentdisplay decreasing key

key :Span fine adjustmentdisplay increasing key

4

Press the key.The indication of the main display section shows“END”.

5

Press the key.After quitting from Span fine adjustment mode,the main display section shows the display valuecorresponding to the present input voltage.

5

Page 34: Voltage input specification digital peak holder CSD-819C-31€¦ · Be sure to read this instruction manual before use. 1. Installation place In this instruction manual, the connection

26

4−2−5. Calibration procedure to apply registration again for zero point only

(1)Procedures by key operation

Warning ● During the execution of calibration, be sure to set cancellation of the Compensateddata at Zero set (Execution of F−98)

● When the changeover target of the calibration data is set to the changeover byexternal control input(Setting of F−80: “00001” or “00011”), execute the calibrationafter the changeover of the calibration data changed by the external controloutput(SEL.1 and SEL.2).

● During the calibration procedure, press the key to interrupt the calibration. Thecalibration data will keep the same condition as it is entered before, then returns tothe Measurement mode.

● When the key is pressed with the setting display section of “FUNC”, the displaywill change as the following arrow marks indicate at every time the key is pressed.

However, every time the is pressed, the display will change as the reversedirection of the following arrow marks.“FUNC”→“CCAL”→“LCAL”→“ZERO”→“SPAN”→“TARE”→“CHEK”→“MONT”→“VCAL”→“VADJ”→“SYMM”→“FUNC”→“CCAL”→・・・・・(Hereinafter, it will repeat.)

Procedures

1

Press the key for about one secondThe setting display section shows “FUNC”.The main display value continuously shows thedisplay value corresponding to the present inputvoltage.

2

Press the key five times.It makes the setting display section proceeded as“FUNC”→“CCAL”→“LCAL”→“ZERO”→“SPAN”→“TARE”.Here, set the input voltage to 0 V.

Page 35: Voltage input specification digital peak holder CSD-819C-31€¦ · Be sure to read this instruction manual before use. 1. Installation place In this instruction manual, the connection

27

Procedures

3

Press the key.The “TARE” mode can be entered.The display on the main display section shows“ZERO”.

Press the key.The display of “ZERO” on the main displaysection flashes on and off, and the cancellation ofthe input voltage is entered.

Warning :Take care not to apply thefluctuation on the input voltage.If any fluctuation on the voltage is applied,the zero point will not stabilized, in duecourse there is a possibility that correctreading of zero won’t be obtained.

4

Upon completed, the indication of the maindisplay section shows “END”.However, when the input voltage isn’tentered within the range of-0.5 V and 0.5 V,the error code in the right is shown for about2 seconds, then the display on the maindisplay section shows “ZERO”, and returns tothe step 3.

TE−L:Zero point -OVERTE−H:Zero point +OVER

Error code

Error code

Press the key.After quitting from the “TARE” mode, the maindisplay section shows the display value

d h l

5

p y p ycorresponding to the present input voltage.

Page 36: Voltage input specification digital peak holder CSD-819C-31€¦ · Be sure to read this instruction manual before use. 1. Installation place In this instruction manual, the connection

28

4−2−6. Compensation of symmetric property(Fine adjustment of minus side span)

(1)Procedures by key operation

● During the execution of zero set, or Peak ON, compensation of symmetric propertymode can’t be entered into(Display ER−5).The Compensation of symmetric property can be entered after the cancel of thecompensation data at Zero set(Execution of F−98), and set the peak OFF.

● When the changeover target of the calibration data is set to the changeover byexternal control input(Setting of F−80: “00001” or “00011”), execute the calibrationafter the changeover of the calibration data changed by the external control output(SEL.1 and SEL.2).

● During the calibration procedure, press the key to interrupt the calibration. Thecalibration data will keep the same condition as it is entered before, then returns tothe Measurement mode.

● When the key is pressed with the setting display section of “FUNC”, the displaywill change as the following arrow marks indicate at every time the key is pressed.

However, every time the key is pressed, the display will change as the reversedirection of the following arrow marks.“FUNC”→“CCAL”→“LCAL”→“ZERO”→“SPAN”→“TARE”→“CHEK”→“MONT”→“VCAL”→“VADJ”→“SYMM”→“FUNC”→“CCAL”→・・・・・(Hereinafter, it will repeat.)

● As for the compensation of symmetric property, the polarity becomes effective only forthe indicated value on a minus side.

● This instrument can make the compensation of approx.±0.5 % to the maximumdisplay value setting.

● When the compensation of symmetric property is executed, zero point might bechanged.

Procedures

1

Press the key for about one secondThe setting display section shows “FUNC”.The main display value continuously shows thedisplay value corresponding to the present inputvoltage.

Page 37: Voltage input specification digital peak holder CSD-819C-31€¦ · Be sure to read this instruction manual before use. 1. Installation place In this instruction manual, the connection

29

Procedures

2

Press the key ten times.It makes the setting display section proceeded as“FUNC”→“CCAL”→“LCAL”→“ZERO”→“SPAN”→“TARE”→“CHEK”→“MONT”→“VCAL”→“VADJ”→“SYMM”.Here, input the maximum voltage less than themaximum display value on a minus side.

3

Press the key.Enters to the symmetric property compensationmode, and the display of main display sectionblinks. At the same time, adjust the display to bethe same display corresponding to the inputvoltage with the right keys.

By pressing the key continuously,increment can be provided continuously.

The variation of load value for one push ofthe right key is less than 1 digit of display.Therefore, a few pushes of these keys arerequired to get the change of 1 digit ofdisplay value.

key :Span fine adjustmentdisplay decreasing key

key :Span fine adjustmentdisplay increasing key

4

Press the key.The indication of the main display section shows“END”.

5

Press the key.After quitting from the compensation mode ofsymmetric property, the main display sectionshows the display value corresponding to thepresent input voltage.

5

Page 38: Voltage input specification digital peak holder CSD-819C-31€¦ · Be sure to read this instruction manual before use. 1. Installation place In this instruction manual, the connection

30

4−3. Monitor mode

In the monitor mode, the present input voltage is displayed after converting into V.

● The value displayed in the monitor mode is a reference value.The display accuracy is about 0.5 %.

● The range which can be monitored in the monitor mode is almost-10.000 to 10.000.

● A minimum display digit in the monitor mode is five count increment.Therefore, the value of the minimum display digit becomes either of“0” or “5”.

● When the key is pressed with the setting display section of “FUNC”, the displaywill change as the following arrow marks indicate at every time the key is pressed.

However, every time the key is pressed, the display will change as the reversedirection of the following arrow marks.“FUNC”→“CCAL”→“LCAL”→“ZERO”→“SPAN”→“TARE”→“CHEK”→“MONT”→“VCAL”→“VADJ”→“SYMM”→“FUNC”→“CCAL”→・・・・・(Hereinafter, it will repeat.)

Procedures

1

Press the key for about one secondThe setting display section shows “FUNC”.The main display section continuously shows thedisplay value corresponding to the present inputvoltage.

2

Press the key ten times.It makes the setting display section proceeded as“CCAL”→“LCAL”→“ZERO”→“SPAN”→“TARE”→“CHEK”→“MONT”.

Page 39: Voltage input specification digital peak holder CSD-819C-31€¦ · Be sure to read this instruction manual before use. 1. Installation place In this instruction manual, the connection

31

Procedures

3

Press the key.The monitor mode can be entered, and thepresent input voltage on the main display sectionflashes on and off.

4

Press the key.The main display section displays “END”.

5

Press the key.After quitting from the monitor mode, the miandisplay section shows the display valuecorresponding to the present input voltage.

Page 40: Voltage input specification digital peak holder CSD-819C-31€¦ · Be sure to read this instruction manual before use. 1. Installation place In this instruction manual, the connection

32

5. Function mode

● A set change by the function mode is possible in the measurement mode.

● When the display is treated as a target of HOLD (F−10), the Function mode can’t beentered with the condition of inputting the HOLD signal. Before entering Functionmode, be sure to cancel the input of HOLD.

5−1. Setting method for function mode

Procedures

1

Press the key for one second.The setting display section shows “FUNC”.The main display section continuously displaysthe display value corresponding to the presentinput voltage.

2

Press the key. Function mode can beentered, then the setting display section shows“F−**”, and the digit of 100 will flash on and off.The last called Function No. is shown at **.Suspend the setting of Function mode, then press

the key when returning to the Measurementmode is required.

3

Select the Function No. desired to set with theright keys.Suspend the setting of Function mode, thenMeasurement mode can be re−entered by

pressing the key.

By pressing the key continuously,continuous increase will be provided. key :Set value carry key

key :Set value increment key

key :Set value initialization key

Page 41: Voltage input specification digital peak holder CSD-819C-31€¦ · Be sure to read this instruction manual before use. 1. Installation place In this instruction manual, the connection

33

Procedures

4

Press the key.Content of setting Function that has selected isdisplayed and the digit of 100 will flash on and offin the main display section.Change the setting with the right keys.

Press the key to suspend the setting ofFunction mode, then return to the measurementmode.

By pressing the key continuously,continuous increase will be provided.

key :Set value carry key

key :Set value increment key

key :Set value initialization key

5

Press the key.The set contents are registered, then the maindisplay section returns to the registered FunctionNo., and the 100 digit will flash on and off.

Press the key.Setting another Function No. is desired, returnto step 3.

6

Press the key.Quitting the Function mode, the Measurementmode can be returned.

Page 42: Voltage input specification digital peak holder CSD-819C-31€¦ · Be sure to read this instruction manual before use. 1. Installation place In this instruction manual, the connection

34

5−2. Function of function data

・ F−01 Selection of decimal point at display positionInitial value=00000 00000=Non

00001=101

00002=102

00003=103

00004=104

※The selected each calibration data can be set.

・ F−02 Selection of A/D sampling rateInitial value=00003 00000:100 times/s

00001:500 times/s00002:1 000 times/s00003:2 000 times/s

・ F−03 Selection of display rateInitial value=00001 00000=4 times/s

00001=20 times/s00002=50 times/s00003=100 times/s

・ F−04 Setting digital filterInitial value=00055 Setting range:=00000~00088, Average of 2(m)+2(n) times

100 digit:Average of 2n times101 digit:Average of 2m times

※Select the average times for digital filter. When the figure grows larger, the filter willbecome stronger, then effects from vibrations and so on are shown scarcely on thedisplay. However, if too large figure is selected, the response to variation of inputsensor will become worse.

※Using the digital filter where vibrations and so on may exist is effective for removingthe deflection on the display.

・ F−05 Setting analog filterInitial value=00002 00000=10 Hz

00001=100 Hz00002=1 kHz

・ F−06 Setting key lock

Initial value=00000 100 digit: key

101 digit: key

102 digit: key

103 digit: key

104 digit: key※Key lock cancellation is made by setting “0”, and key lock is made by setting “1”.

Moreover, when the key is locked, and the key is cancelled only once

immediately after by pressing the key for more than 3 seconds with the keypressed together.

Page 43: Voltage input specification digital peak holder CSD-819C-31€¦ · Be sure to read this instruction manual before use. 1. Installation place In this instruction manual, the connection

35

・ F−10 Setting of the target of HOLDInitial value=11111 100 digit:Main display

101 digit:Comparator S0 open collector output, LED display102 digit:Comparator S1, S2, S3 and S4 open collector output,

LED display103 digit:Analog output104 digit:Optional BCD output

※Out of the target at the setting “0”, and target of HOLD is available at the setting “1”.

・ F−20 Setting the target of analog outputInitial value=00000 00000:TRACK

00001:Display interlock※ It is common to all of four kinds of calibration data and executed.

・ F−21 Display value at the time of the minimum analog outputInitial value=00000 Setting rage -99999~99999※ The selected each calibration data can be set.

・ F−22 Display value at the time of the maximum analog outputInitial value=02000 Setting rage -99999~99999※ The selected each calibration data can be set.

・ F−30 Setting comparator operationInitial value=11111 0=OFF

1=ON100 digit:Comparator S0101 digit:Comparator S1102 digit:Comparator S2103 digit:Comparator S3104 digit:Comparator S4

※ It is common to all of four kinds of calibration data and executed.

・ F−31 Setting the target of comparatorInitial value=00000 0=TRACK

1=Synchronous with display100 digit:Comparator S0101 digit:Comparator S1102 digit:Comparator S2103 digit:Comparator S3104 digit:Comparator S4

※ It is common to all of four kinds of calibration data and executed.

・ F−32 Setting the direction of comparatorInitial value=00000 0=Greater or equal

1=less or equal100 digit:Comparator S0101 digit:Comparator S1102 digit:Comparator S2103 digit:Comparator S3104 digit:Comparator S4

※ It is common to all of four kinds of calibration data and executed.

Page 44: Voltage input specification digital peak holder CSD-819C-31€¦ · Be sure to read this instruction manual before use. 1. Installation place In this instruction manual, the connection

36

・ F−33 Setting applicable condition for the comparator S0Initial value=00000 00000=ON when comparator S0 is in the condition of

main display value≧(The maximum display value)00001=ON when both of S1 and S2 open collector output are off.00002=ON when both of S1 and S3 open collector output are off.00003=ON when both of S1 and S4 open collector output are off.00004=ON when both of S2 and S3 open collector output are off.00005=ON when both of S2 and S4 open collector output are off.00006=ON when both of S3 and S4 open collector output are off.00007=Operate whichever “Open collector ON more than the set

value” or “Open collector ON below the set value”.00008=Interlock with HOLD LED00009=Interlock with PEAK LED00010=Interlock with MEAS. LED

※ It is common to all of four kinds of calibration data and executed.

・ F−34 Setting the condition of Hysteresis operation for comparatorInitial value=00000 00000=ON delay

00001=OFF delay※ It is common to all of four kinds of calibration data and executed.

・ F−35 Setting Hysteresis data for comparatorInitial value=00000 00000=Hysteresis data width OFF

Setting rage:00000~00099Unit:1DData width of 99D at the setting of “00099”.

※ It is common to all of four kinds of calibration data and executed.

・ F−36 Setting Hysteresis time width for comparatorInitial value=00000 00000=Hysteresis time width OFF

Setting rage:00000~00099Unit:0.1 sData width of 9.99 s at the setting of “00999”

※ It is common to all of four kinds of calibration data and executed.

・ F−38 Setting light ON/OFF of comparative value display sectionInitial value=00000 00000=Light ON

00001=Light OFF

・ F−40 Setting the target of BCD output(Effective when the option is installed.)Initial value=00000 00000=TRACK

00001=Display interlock

・ F−41 Setting the logic of BCD output (Effective when the option is installed.)Initial value=00000 00000=Negative logic

00001=Positive logic

・ F−42 Setting the polarity of BCD output (Effective when the option is installed.)Initial value=00000 00000=Negative logic

00001=Positive logic

・ F−43 Setting the logic of BCD flag output (Effective when the option is installed.)Initial value=00000 00000=Negative logic

00001=Positive logic

・ F−44 Setting the logic of BCD P.C. output (Effective when the option is installed.)Initial value=00000 00000=Negative logic

00001=Positive logic

Page 45: Voltage input specification digital peak holder CSD-819C-31€¦ · Be sure to read this instruction manual before use. 1. Installation place In this instruction manual, the connection

37

・ F−45 Setting the BCD P.C. width(Effective when the option is installed.)Initial value=00004 00000=125 ms

00001=25 ms00002=10 ms00003=5 ms00004=2.5 ms

・ F−46 Setting BCD output times(Effective when the option is installed.)Initial value=00004 00000=4 times/s

00001=20 times/s00002=50 times/s00003=100 times/s00004=200 times/s

・ F−50 Setting the operation mode of RS−232C(Effective when the option is installed.)

Initial value=00001 00000=Stream mode00001=Command mode

・ F−51 Setting the target of output at the time of stream mode of RS−232C(Effective when the option is installed.)

Initial value=00000 00000=TRACK00001=Display interlock

※In the Command mode, the data are transferred from the host by the command.In the Stream mode, the latest data is output continuously.

・ F−52 Setting the baud rate of RS−232C/422/485(Effective when the option is installed.)

Initial value=00003 00000=1 200 bps00001=2 400 bps00002=4 800 bps00003=9 600 bps00004=19 200 bps00005=38 400 bps

・ F−53 Setting the data bit length and parity of RS−232C/422/485(Effective when the option is installed.)

Initial value=00021 100 digit:Setting data bit length0=8 bit1=7 bit

101 digit:Setting parity0=No parity1=Even number parity2=Odd number parity

・ F−54 Setting the stop bit of RS−232C/422/485(Effective when the option is installed.)

Initial value=00000 00000:1 bit00001:2 bit

・ F−55 Setting the terminator of RS−232C/422/485(Effective when the option is installed.)

Initial value=00001 00000:CR00001:CR+LF

Page 46: Voltage input specification digital peak holder CSD-819C-31€¦ · Be sure to read this instruction manual before use. 1. Installation place In this instruction manual, the connection

38

・ F−56 Setting the decimal point of sending code of RS−232C/422/485(Effective when the option is installed.)

Initial value=00000 00000:No decimal point00001:Yes of Decimal point

・ F−57 Setting the ID number of RS−422/485(Effective when the option is installed.)Initial value=00000 Setting range:00000~00031

・ F−58 Changing RS−422/485(Effective when the option is installed.)Initial value=00000 00000:RS−422

00001:RS−485

・ F−59 Setting the delay time of returning RS−485Initial value=00005 Setting range:00000~00999

Unit 1 msThe delay is 999 ms at the “00999” setting.

・ F−60 Setting the Peak, Bottom and Peak bottom holdInitial value=00000 00000:Peak hold

00001:Bottom hold00002:Peak bottom hold00003:Local minimal value hold00004:Local maximal value hold00005:Inflection point hold

・ F−61 Setting the kinds of detecting modeInitial value=00000 00000:All zone specification

00001:Zone specification00002:Time zone specification00003:Automatic start time zone specification

・ F−62 Setting referring point(Effective when peak/bottom holding condition)Initial value=00000 Setting range:-99999~99999

・ F−63 Setting the detecting data width of local maximal/minimal value(Effective when local maximal/minimal value holding condition)

Initial value=00200 Setting range:00000~99999

・ F−64 Setting the detecting magnification of local maximal/minimal value(Effective when local maximal/minimal value holding condition)

Initial value=00015 Setting range:00000~00049Unit:0.1 times

・ F−65 Setting the detecting data width of inflection point(Effective when inflection point detecting condition)

Initial value=00100 Setting range:-99999~99999

・ F−66 Setting the detecting time width A of inflection point(Effective when inflection point detecting condition)

Initial value=00100 Setting range:00000~00450Unit:1 ms

・ F−67 Setting the detecting time width B of inflection point(Effective when inflection point detecting condition)

Initial value=00100 Setting range:00000~00450Unit:1 ms

・ F−68 Setting the detecting time of holding(Effective when the holding mode of time zone or automatic start time zone)

Initial value=01000 Setting range:00000~09999Unit:1 ms

Page 47: Voltage input specification digital peak holder CSD-819C-31€¦ · Be sure to read this instruction manual before use. 1. Installation place In this instruction manual, the connection

39

・ F−69 Setting the start level of automatic start(Effective when automatic start time zone mode.)

Initial value=01000 Setting range:-99999~99999

・ F−71 Setting the storing area of ZERO dataInitial value=00000 00000=RAM

00001=EEPROM※Selects whether the data at the time of ZERO should be recorded at the EEPROM ornot. In case that the high frequency of use of ZERO, the durability times will be over,so set “0”. The durability times for the EEPROM will be approx. one million times.

※ It is common to all of four kinds of calibration data and executed.

・ F−72 Setting the effective time for external control inputInitial value=00000 00000:50 ms

00001:20 ms00002:10 ms00003:5 ms00004:2 ms00005:1 ms

・ F−75 Symmetric property compensation value(for reference)※ The compensation value set when the symmetric property compensation is executedcan be referred.

※ A setting here cannot be changed.※ The reference value here is a value to the calibration data which has been selected.

・ F−80 Setting to the changeover target of calibration data and comparator codeInitial value=00000 0=Changeover by the function(F−81 or F−82)

1=Changeover by external control input100 digit:Calibration data101 digit:Code

・ F−81 Setting of the calibration data selectionInitial value=00000 00000:Calibration data 0

00001:Calibration data 100002:Calibration data 200003:Calibration data 3

・ F−82 Setting of the comparator code selectionInitial value=00000 00000:Code 0

00001:Code 100002:Code 200003:Code 3

・ F−90 Increment value (For reference)※ The increment value set when the calibration is applied can be referred to.※ The setting can’t be changed in the function.※ The reference value here is the value for the selecting calibration data.

・ F−91 The maximum display value (For reference)※The maximum display value set when the calibration is applied can be referred to.※The setting can’t be changed in the function.※ The reference value here is the value for the selecting calibration data.

・ F−92 The actual load value (For reference)※The actual load value set when the calibration is applied(LCAL) can be referred to.※When the calibration except LCAL is made, this value will not change.※The setting can’t be changed in the function.※ The reference value here is the value for the selecting calibration data.

Page 48: Voltage input specification digital peak holder CSD-819C-31€¦ · Be sure to read this instruction manual before use. 1. Installation place In this instruction manual, the connection

40

・ F−93 Zero calibration value (For reference)※The input voltage value that has read as the initial load value at the time of executingcalibration can be referred to.

※The setting can’t be changed in the function.※ The reference value here is the value for the selecting calibration data.

・ F−94 Span calibration value (For reference)※The input voltage value at the time of the maximum display can be referred to.※The setting can’t be changed in the function.※ The reference value here is the value for the selecting calibration data.

・ F−95 Internal calibration data value①(for our maintenance)※The setting can’t be changed in the function.※ The reference value here is the value for the selecting calibration data.

・ F−96 Internal calibration data value①(for our maintenance)※The setting can’t be changed in the function.※ The reference value here is the value for the selecting calibration data.

・ F−97 Prohibition of calibrationInitial value=00000 00000=Possible to calibrate

00001=Prohibition from calibration※ It is common to all of four kinds of calibration data and executed.

・ F−98 ZERO clearZero compensated data by zero set function can be cancelled.

When the key is pressed with “F−98” displayed, “ZCLR” can be displayed.(At the same time, the display lights on and off.)

At this point, press the key when suspending the ZERO clear is desired.Measurement mode can be returned and Zero clear will not be executed.

When the key is pressed while “ZCLR” display lights on and off, “F−98” display canbe returned. Now, ZERO clear has completed.※ The selected each calibration data is executed.

・ F−99 Memory clearSetting from F−01 to F−97 recorded at EEPROM will return to the default value.

When the key is pressed with the display of F−99, then “FCLR” display can be

obtained. (At the same time, the display lights on and off.) At this point, press thekey when suspending memory clear is desired. Measurement mode can be returned andMemory clear will not be executed.

When the key is pressed during the display of “FCLR” lights on and off, and afterabout 1 second, it will become “FUNC” display and the operation of Memory clear hascompleted.

Warning ● Never use the following functions because they may destroy the functions at internalof the instrument.

F−00 F−07 F−08 F−09 F−11 F−12 F−13 F−14

F−15 F−16 F−17 F−18 F−19 F−23 F−24 F−25

F−26 F−27 F−28 F−29 F−37 F−39 F−47 F−48

F−49 F−70 F−73 F−74 F−76 F−77 F−78 F−79

F−83 F−84 F−85 F−86 F−87 F−88 F−89

Page 49: Voltage input specification digital peak holder CSD-819C-31€¦ · Be sure to read this instruction manual before use. 1. Installation place In this instruction manual, the connection

41

6. Trouble shooting

When abnormal point(s) is/are found during the operation of the instrument, check by the followingprocedures. However, when you can’t find applicable item nor solve the symptom of trouble even after youhave taken some measures, contact with Minebea.

OK

NG

Supply power, again.

Operation

Normal Operation

Start measurement

Abnormal operation

Execute troubleshooting.

Page 50: Voltage input specification digital peak holder CSD-819C-31€¦ · Be sure to read this instruction manual before use. 1. Installation place In this instruction manual, the connection

42

6−1. Execute trouble shooting

Execute trouble shooting.

Does supplypower voltage satisfy the

specifications?

Display is wrong.

Analog outputis wrong.

Supply power source suitable forthe specifications.

Inform Minebea about thecontents of failure andsituation at site in details.

1

5

2

3

4

NO

YES

YESYES

YES

YES

YES

NO

NO

NO

NO

NO

NO

Operation ofcomparator is wrong.

External control inputdoesn’t operate.

Key operationdoesn’t work.

YES

Operation ofoptions is wrong.

YES

NO

Check the options.Refer to the instructionmanual for CSD−819C

Connecting methodis good.

Page 51: Voltage input specification digital peak holder CSD-819C-31€¦ · Be sure to read this instruction manual before use. 1. Installation place In this instruction manual, the connection

43

Displays the value.

Replace fuse byreferring to theparagraph 13−1 of theinstruction manual forCSD−819C.

Display fluctuatesabnormally.

The displaydoesn’t vary.

Execute the calibration againaccording to the procedures inthe paragraph 4.

Inform Minebea about the contents offailure and situation at site in details.

YES

NO

NO

NO

NO

NO

NO

NO

NO

YES

YES

YES

YES

YES

YES

YES

8

7

1

Displaysoptional values.

OL display

Same situation

Start measurement.

-OL display

7

6

Fuse is broken.

Page 52: Voltage input specification digital peak holder CSD-819C-31€¦ · Be sure to read this instruction manual before use. 1. Installation place In this instruction manual, the connection

44

Operation ofcomparator is the same as

its intention.

Inform Minebea about the contents offailure and situation at site in details.

Contact output chatters.

2

Set value is good. Confirmation/change for set value should bemade according to the paragraph 7−2−3 ofthe instruction manual for CSD−819C.

Confirmation/change for operation ofcomparator, comparative target forcomparator should be made according to theparagraph 7−2−4, 7−2−5 and 7−2−6 of theinstruction manual for CSD−819C.

Apply setting for hysteresis according to theparagraph of the instruction manual forCSD−819C.

NO

YES

YES

NO

NO

YES

Contact output isn’t ON.

NO

YES

Connecting method is good.

YES

NOConnect securely according to the paragraph4−3−3 and 7−1−2 of the instructionmanual for CSD−819C.

Following causes can be considered.1 Failure in contact by using other than therated capacity of contact.Capacity of contact:VCE = DC30 V,

IC = 30 mA at maximum.2 Failure in customer’s input circuit.Confirm the contact output signal byreferring to the paragraph 7−15 of theinstruction manual for CSD−819C.

Page 53: Voltage input specification digital peak holder CSD-819C-31€¦ · Be sure to read this instruction manual before use. 1. Installation place In this instruction manual, the connection

45

ZERO inputdoesn’t operate.

Connect securely according tothe paragraph 4−3−2 and7−1−1 of the instructionmanual for CSD−819C.

Inform Minebea about thecontents of failure andsituation at site in details.

YES

NO

PEAK/TRACKinput doesn’t work.

3

YES

YES

NO

NO

Displays ER−0.YES

NO

Other than the range of Zeroset.

Range of zero set is within±10 % of the maximumdisplay value.

RESET inputdoesn’t work.

NO Either the HOLDof external input or BCD

output is used.Set the HOLD input open.

HOLD inputdoesn’t work.

YES

Connecting methodis good.

YES

NO

YES

NO

Page 54: Voltage input specification digital peak holder CSD-819C-31€¦ · Be sure to read this instruction manual before use. 1. Installation place In this instruction manual, the connection

46

Key lock is set with thefunction F−06.

Inform Minebea about the contents offailure and situation at site in details.

HOLD of externalcontrol input is used.

4

Cancel the key lock with the functionF−06.

Set the HOLD input open.

NO

NO

YES

YES

Page 55: Voltage input specification digital peak holder CSD-819C-31€¦ · Be sure to read this instruction manual before use. 1. Installation place In this instruction manual, the connection

47

1 Remove the connecting cable between the A−OUT terminals.2 Measure the voltage between the A−OUT terminal+ and-.

Set the connecting range to DC・V range for the measuring instrumentsuch as tester and so on.

3 Apply operational check on voltage output in the Check mode.(Refer to the paragraph 7−15 of the instruction manual for CSD−819C.)

1 Put the connecting cable for the A−OUT terminal where it was.2 Check the setting related with voltage output.

● F−21 Display value when analog output is the minimum.

● F−22 Display value when analog output is the maximum.

(Refer to the paragraph 8 of the instruction manual for CSD−819C.)

5

Contact with Minebea.

YES

NO

YES

10

Varies to 0 V, 5 Vand 10 V.

Setting is correct.

HOLD for externalcontrol input is applied.

Set correctly.Refer to the paragraph 8 of theinstruction manual for CSD−819C.

NO

Set the HOLD input open.

NO

YES

YES

Inform Minebea about thecontents of failure andsituation at site in details.

Option ofcurrent output

YES

NO

Load resistance is5 kΩ or more.

Load resistance should be 5 kΩor more.

NO

Page 56: Voltage input specification digital peak holder CSD-819C-31€¦ · Be sure to read this instruction manual before use. 1. Installation place In this instruction manual, the connection

48

6

The voltage betweenB and D varies.

Same condition

NO

YES

Please change the input voltage while seeing the voltage between terminals Band D of the terminal block.

Please make the connected range of the measuring instruments such astesters to the range of DC・V.

Start measurementYES

NO

Make re−calibration accordingto the procedures in paragraph 4.

There may have fears that theconnected signal route (signal wire)has cut off.

Inform Minebea about thecontents of failure andsituation at site in details.

Page 57: Voltage input specification digital peak holder CSD-819C-31€¦ · Be sure to read this instruction manual before use. 1. Installation place In this instruction manual, the connection

49

Input voltage valueexceeds the range from-0.5 V

to 0.5 V.

7

Start measurement

Same condition

Following causes can beconsidered・The signal route(signalwires) has been cut off.

YES

NO

YES

NO

NO

Monitoring displayexceeds the range from-0.5 V

to 0.5 V

YES

Remove the connected signal wiresfor input voltage and short betweenB and D on the terminal block.

Make re−calibration according tothe procedures of paragraph 4.

Inform Minebea about thecontents of failure andsituation at site in details.

Page 58: Voltage input specification digital peak holder CSD-819C-31€¦ · Be sure to read this instruction manual before use. 1. Installation place In this instruction manual, the connection

50

Short−circuit between B and D ofthe terminal block.

8

NO

NO

YES

YES

Start measurement.

Same condition

The displaystabilizes with the optional

value.

Check the various kinds of connecting conditionsaccording to the procedures in the paragraph 3.Especially, check that there may have effects from thenoise source such as an inverter or like that.

Inform Minebea about the contents offailure and situation at site in details.

Page 59: Voltage input specification digital peak holder CSD-819C-31€¦ · Be sure to read this instruction manual before use. 1. Installation place In this instruction manual, the connection

51

6−2. Error display

Errorcode

Contents of error Remedy

ER−0 Zero set has executed with more than±10 % of the maximum display value.

Apply zero set after making it within±10 % of maximum display value.

ER−1 Setting mistake Set correctly.

ER−2 Mistake in setting during calibration Set correctly.

ER−5 At the time of fine adjustment on zero or span,it is shown when zero set, and peak are ON.

Set OFF while the peak is ON.Apply ZERO clear(F−98).

ER−6 When prohibiting the calibration is set,calibration or fine adjustment for analog isproceeded.

Remove the prohibition of calibration(F−97).

HOLD Powered ON with the HOLD input is shorted. Set the HOLD input open.

TE−L Displays when the initial value at the time ofcalibration is less than-0.5 V.

TE−H Displays when the initial input at thecalibration is more than 0.5 V, or the totalvalue with the initial input and the inputequal to the maximum display value exceeds10 V.

Adjust so that the initial input is withinthe range from-0.5 V to 0.5 V

SP−L The input equal to the maximum display valueat the time of calibration (LCAL) is less than1 V, or the difference between the initial inputand the input equal to the maximum displayvalue is less than 1 V. Adjust so that the input equal to the

maximum display value is within theSP−H The input equal to the maximum display value

at the time of calibration (LCAL) exceeds 10 V,or the difference between the initial input andthe input equal to the maximum display valueexceeds 10 V.

maximum display value is within therange from 1 V to 10 V.

ER−E EEPROM errorContact with Minebea

ER−R EEPROM errorContact with Minebea.

OL Displays when 110 % of the maximum displayvalue is exceeded at the time of measurementor in calibration. Set so that the display will be within the

-OL Displays when-110 % of the maximumdisplay value is exceeded at the time ofmeasurement or in calibration.

Set so that the display will be within therange from−110 % to 110 %.

Page 60: Voltage input specification digital peak holder CSD-819C-31€¦ · Be sure to read this instruction manual before use. 1. Installation place In this instruction manual, the connection

52

7. Specifications

7−1. Specifications for analog section

DC voltage input range F.S. setting can be made at the input of±1 V to±10 V(Input resistance Approx.1 MΩ)

Output range DC±10 V Load resistance 5 kΩ or more (F.S. setting by function)

Output times 100 times/s, 500 times/s, 1 000 times/s or 2 000 times/s changeable.(Synchronizes with the A/D sampling.)

Output resolution As same as display resolution

Non−linearityDisplay 0.05 %F.S.Output 0.05 %F.S.

Temperature coefficientZero point ±0.01 %F.S./℃Sensitivity ±0.01 %F.S./℃

Input filter 10 Hz, 100 Hz and 1 kHz

A/D sampling 2 000 times/s (100 times/s, 500 times/s or 1 000 times/s changeable)

7−2. Specifications for digital section

Main displayDisplay range -11 000 to 11 000Display increment 1 (2, 5 or 10 changeable)Display unit Red 7segment LED Character height 17 mmOver display “-OL” display at the minus over, “OL” display at the plus over

Comparator displayDisplay range -99 999 to 99 999Display unit Green 7 segment LED Character height 8 mmNumber of display 1 point (Selectable from S0, S1, S2, S3 and S4)

Condition display SEL.1, SEL.2, CHECK, HOLD, PEAK, MEAS. and END

Judgement display S0, S1, S2, S3 and S4

Display times 20 times/s(4 times/s, 50 times/s or 100 times/s changeable)

Decimal point display No display, 101, 102, 103 or 104 changeable

7−3. Front panel sheet key function

Change of Function mode

Zero set

S※ set value display/Carry on set value

Increment of set value

Changeover of Track and Peak hold, Bottom hold, Peak bottom hold,Local maximal value hold, Local minimal value hold or Inflection point hold(When all zone specified mode)Or control of holding zone in zone specification mode or time zonespecification mode.

Reset of peak value During ON, the display is fixed to zero(0).

Not used in this voltage input function

Enter key

Page 61: Voltage input specification digital peak holder CSD-819C-31€¦ · Be sure to read this instruction manual before use. 1. Installation place In this instruction manual, the connection

53

7−4. External control function

ZERO Same as the key※Above is pulse input, and effective once at the pulse input and the pulsewidth is 50 ms or more. (Pulse width is changeable to 1 ms, 2 ms, 5 ms,10 ms or 20 ms.)

PEAK/TRACK Change of Track and Peak hold, Bottom hold, Peak bottom hold, Localmaximal value hold, Local minimal value hold or Inflection point hold(It can be changed by the function.)Or control of holding zone in zone specification mode or time zonespecification modeOpen :TrackShort :Peak hold, Bottom hold, Peak bottom hold, Local maximal value

hold, Local minimal value hold or Inflection point hold(It can be changed by the function.)

HOLD Hold of Display, Comparative output, Analog output and BCD output

RESET Same as the key, reset condition can be made by short.

SEL.1, SEL.2 Changeover of 4 kinds for “Comparator code” or “Calibration data”combined with SEL.1 and SEL.2.(Select the changeover target from “Comparator code” or “Calibration data”by the function.)※ Above is level input, and effective during the short input more than 50 ms.(Level width Changeable to 1 ms, 2 ms, 5 ms, 10 ms or 20 ms)

Equivalent circuit of external control input.+5 V

INPUT

COM.1

1kΩ

3 300 pF

+12 V+12 V

10 kΩ 2.2kΩ

7−5. Comparator function

Set value -99 999 to 99 999

Numbers of setting 5 points (S0, S1, S2, S3 and S4)※Comparator function of “S0” is set by function.

Set value for hysteresis data 0 to 99 digits

Setting hysteresis time width 0 to 9.99 s

Hysteresis direction Can be selected whichever “On delay” or “Off delay”.

Conversion times for comparator100 times/s, 500 times/s, 1 000 times/s and 2 000 times/s changeable.

Page 62: Voltage input specification digital peak holder CSD-819C-31€¦ · Be sure to read this instruction manual before use. 1. Installation place In this instruction manual, the connection

54

7−6. Open collector output signal

S1, S2, S3, S4 Open collector ON when reached under/over the comparator set value.

S0 Open collector ON with either condition in below by function setting.・During the FULL condition (100 % of rated load).・When the both two of S1, S2, S3 and S4 are OFF condition.・Operates when reached under/over the S0 set value.(Same as the comparative operation of S1, S2, S3 and S4.)

・ON interlocked to HOLD LED of condition display・ON interlocked to PEAK LED of condition display・ON interlocked to MEAS. LED of condition display

Open collector specificationsVCE=DC30 V, IC=30 mA MAX.

Equivalent circuit of contact output section

OUTPUT

COM.2

7−7. Various kinds of functions

Digital filter Stabilizes the data by the computing process through CPU.

Change of target of HOLD With the combination of “Display”,“Comparative output”, “Analogoutput”, “BCD output(Option)”, target of HOLD can be made.

Sheet key lock Prohibition of operation of optional key.

Change of target The target of analog output can be changed either “TRACKof analog output value” and “Interlock of display”.

Change of calibration data Four kinds of calibration data can be memorized, and they beselected by the function or the external control input.(The changeover target of ”Calibration data” and ”Comparatorcode” is set by the function)

Change of comparator code The set value of the comparator of S0, S1, S2, S3 and S4 can bememorized up to four kinds, and do changeover of them by thefunction or the external control input. (The changeover target of”Calibration data” and ”Comparator code” is set by the function)

Selection of Peak mode Selectable from six mode of Peak hold, Bottom hold, Peak/bottomhold, Local maximal value hold, Local minimal value hold andInflection point hold by 24 modes by which four kinds of zone modeof All zone specification, Zone specification, Time zone specificationand Automatic start time zone specification are combined.

7−8. General specifications

Operating temperature/humidity rangeTemperature −10℃ to 50℃Humidity Less than 85 %RH (Non condensing.)

Power supplyPower supply voltage AC100 V to AC240 V

(Permissible variation range:AC85 V to AC264 V)Power supply frequency 50/60 HzPower consumption Approx. 8 VA(Without option, at AC100 V)

Approx. 17 VA at max. (With option, at AC100 V to AC240 V)

Outline dimensions(W×H×D) 96 mm×96 mm×129.5 mm (Excludes protruding parts.)

Weight Approx.500 g (Without any options.)

Page 63: Voltage input specification digital peak holder CSD-819C-31€¦ · Be sure to read this instruction manual before use. 1. Installation place In this instruction manual, the connection

55

7−9. Standard specifications at the shipment

Span adjustment ±2 000 display at the input of±1 V

The minimum scale 1

Analog output DC0 V to±10 V at 0 to±2 000 display

7−10. Accessories

Instruction manual 1 piece

Time lug fuse 1 piece (1 A)

Unit seal 1 piece

Metal fittings to install panel 2 pieces

BCD output plug 1 piece(Attached only when optional BCD output is installed.)

7−11. Options

7−11−1. Current output

・ P/N CSD819C-P07

・ SpecificationsOutput DC4 mA to 20 mA Load resistance 260Ω or lessNon−linearity 0.05 %F.S.Resolution As same as display resolutionOver range “-OL” display at approx.DC2.4 mA and “OL” display at approx.DC21.6 mA.Output rate Changeable to 100 times/s, 500 times/s, 1 000 times/s and 2 000 times/s

(Synchronous with A/D sampling rate.)※Voltage output isn’t available when this option is installed.

7−11−2. BCD output

・ P/N CSD819C−P15

・ SpecificationsOutput ・BCD 5 digits Parallel output, with polarity(POL.) applied

(Output ON with minus, and output OFF with plus.)・P.C.(Print command)ON for a fixed time after conversion of BCD output is completed.

・ERROR ON at the time of various errors are occurred.・OVR(over)Above are open collector outputs. VCE=DC30 V, IC=DC20 mA MAX・Output rate Changeable to 4 times/s, 20 times/s, 50 times/s, 100 times/s

and 200 times/s

Input ・ZERO Same as the key.※Above pulse input and pulse width is 50 ms or more is effective once.(Pulse width is changeable to 1 ms, 2 ms, 5 ms, 10 ms and 20 ms.)

・PEAK/TRACKAs same as the key

・RESET As same as the key・HOLD Hold of display and BCD output・BCD−ENABLE Compulsive OFF for the related output of BCD(Hi impedance)※Above are level inputs, and effective during short input of 50 ms or more.(Level width:Changeable to 1 ms, 2 ms, 5 ms, 10 ms or 20 ms.)

Page 64: Voltage input specification digital peak holder CSD-819C-31€¦ · Be sure to read this instruction manual before use. 1. Installation place In this instruction manual, the connection

56

7−11−3. RS−232C interface

・ P/N CSD819C−P74

・ SpecificationsBaud rate :Select from 1 200, 2 400, 4 800, 9 600, 19 200

or 38 400 bps.Data bit length :Select from 7 bits or 8 bits.Parity bit :Select from Non, Even or Odd.Stop bit :Select from 1 bit or 2 bits.Terminator :Select from CR+LF or CR.Communication method: Half−duplexSynchronous method :Start−stop synchronous methodCommunication data :ASCII codeCable length :Within approx. 15 mInput/output monitor :with LED

7−11−4. RS−422/485 interface

・ P/N CSD819C−P76

・ SpecificationsBaud rate :Select from 1 200, 2 400, 4 800, 9 600, 19 200

or 38 400 bps.Data bit length :Select from 7 bits or 8 bits.Parity bit :Select from Non, Even or Odd.Stop bit :Select from 1 bit or 2 bits.Terminator :Select from CR+LF or CR.Communication method: Half−duplexSynchronous method :Start−stop synchronous methodAddress :Select one among 0 to 31.Communication data :ASCII codeCable length :Approx. 1 kmNo. of connections :32 sets at max.(RS−422:10 sets)Termination :Built−in (Yes/No can be selected by the connection with

terminal block.)Input/output monitor :with LED.Change of RS−422/485 :Can be set in Function.

Page 65: Voltage input specification digital peak holder CSD-819C-31€¦ · Be sure to read this instruction manual before use. 1. Installation place In this instruction manual, the connection

57

7−12. Outline dimensions

Unit:mm

Front Side

Rear Upper

Panel cut size

Page 66: Voltage input specification digital peak holder CSD-819C-31€¦ · Be sure to read this instruction manual before use. 1. Installation place In this instruction manual, the connection

58

8.Warranty

8−1. Warranty

・ The instrument is covered by a warranty for a period of one year from the date of delivery.

・ As for repairs and/or after service is required during the period of warranty, contact withMinebea’s sales office or sales agent from which you have purchased.

8−2. Repair

Before asking repairs, make checks once again that the connection, setting and adjustment for the

instrument have finished properly by referring to 9. Trouble shooting.

Especially, make checks whether the connections of sensors are disconnected or cut off.

After that, still there may be found some defects in the instrument, contact with Minebea’s sales

office or sales agency from which you have purchased.

Page 67: Voltage input specification digital peak holder CSD-819C-31€¦ · Be sure to read this instruction manual before use. 1. Installation place In this instruction manual, the connection

59

9.Appendix

9−1. Setting table for functions

※Make use of them in case that the customer has changed setting for the function.

Function No. Initial value Customer’s setting Function No. Initial value Customer’s setting

F−01 00000 F−55 00001

F−02 00003 F−56 00000

F−03 00001 F−57 00000

F−04 00055 F−58 00000

F−05 00002 F−59 00005

F−06 00000 F−60 00000

F−10 11111 F−61 00000

F−20 00000 F−62 00000

F−21 00000 F−63 00200

F−22 02000 F−64 00015

F−30 11111 F−65 00100

F−31 00000 F−66 00100

F−32 00000 F−67 00100

F−33 00000 F−68 01000

F−34 00000 F−69 01000

F−35 00000 F−71 00000

F−36 00000 F−72 00000

F−38 00000 F−75 -

F−40 00000 F−80 00000

F−41 00000 F−81 00000

F−42 00000 F−82 00000

F−43 00000 F−90 -

F−44 00000 F−91 -

F−45 00004 F−92 -

F−46 00004 F−93 -

F−50 00001 F−94 -

F−51 00000 F−95 -

F−52 00003 F−96 -

F−53 00021 F−97 00000

F−54 00000 F−98 -

F−99 -

MEMO

Page 68: Voltage input specification digital peak holder CSD-819C-31€¦ · Be sure to read this instruction manual before use. 1. Installation place In this instruction manual, the connection
Page 69: Voltage input specification digital peak holder CSD-819C-31€¦ · Be sure to read this instruction manual before use. 1. Installation place In this instruction manual, the connection
Page 70: Voltage input specification digital peak holder CSD-819C-31€¦ · Be sure to read this instruction manual before use. 1. Installation place In this instruction manual, the connection

D The contents of this manual may subject to change without notice.

HEAD QUARTER :MINEBEA CO., LTD.4106−73 Miyota, Miyota−machi, Kitasakugun, Nagano−ken 389−0293, Japan

0267−32−2200 .0267−31−1350

Measuring Components Business UnitFUJISAWA PLANT 1−1−1, Katase, Fujisawa−shi Kanagawa−ken, 251−8531 Japan

0466−22−7152 .0466−22−1701

KARUIZAWA PLANT 4106−73 Miyota, Miyota−machi, Kitasakugun, Nagano−ken 389−0293, Japan

0267−31−1309 .0267−31−1350

HOMEPAGE ADDRESS http://www.minebea−mcd.com