VAPOUR LIQUID EQUILIBRIUMUNIT
Equipment for Engineering Education & ResearchSOLTEQ®
MODEL: BP 16
This Vapor-Liquid Equilibrium Unit (Model: BP 16) is a bench top unit designed for students to investigate
the relationship between vapor and liquid at equilibrium for any binary system as well as for multi-
component system. Students may run the unit at atmospheric pressure (i.e. 0 bar (g)) or at an elevated
pressure.
The unit consists of mainly a stainless steel evaporator
fitted with electrical heater and electronic sensors for
the measurement of pressure and temperatures of liquid
and vapour. A stainless steel coil type heat exchanger
is attached at the top of the evaporator. Digital displays
are provided for students to monitor the temperature
and pressure of the vapour in the vessel. A temperature
controller is also provided for the purpose of setting and
adjusting the equilibrium temperature. The unit comes
with a pressure relief valve for safety purposes. The
unit is also well insulated in order to minimize heat
losses. Feed port and sampling ports for both liquid and
vapour are also provided.
EXPERIMENTAL CAPABILITIES
♦ The vapor-liquid relationship at equilibrium for binary
system and multi-component system at
atmospheric pressure as well as at an elevated
pressure.
♦ The effect of initial mixture composition upon the
boiling temperature and vapour liquid phase
compositions.
♦ Determination of minimum boiling point of a binary
mixture.
♦ The effect of adding non-volatile salt on the phase
compositions.
♦ Vapor pressure curve at high pressure.
SOLTEQ
Equipment for Engineering Education & ResearchSOLTEQ®
SPECIFICATIONS
The Vapor-Liquid Equilibrium Unit (Model: BP 16)
comes complete with the following components:
a) Test Rig:
Epoxy coated steel bench with lockable castors.
b) Evaporator:
Cylindrical vessel (jacketed)
Material: stainless steel
Nominal capacity: 6 liter
Tubular heater: 2 kW
Insulation
c) Condenser:
Coil type heat exchanger
Material: stainless steel
Exchange surface: 0.3 m2
Connections for cooling media
Insulation
d) Temperature controller:
Displays bottom liquid temperature
Limits the max. Operating temperature
e) Pressure relief valve:
0 to 10 bar (g)
f) Sampling Devices:
· Stainless steel cooler for bottom product
sampling
· Stainless steel top product sampling vessel
g) Instrumentations:
Temperature sensors and pressure transducer with
digital indicators
h) Control panel:
Electrical wiring and switches
Temperature controller
Digital displays
i) Operating Limits:
Temperature : max. 200°C
Pressure : max. 10 bar(g)
Coolant pressure : max. 2 bar(g)
REQUIREMENTS
Electrical Supply : 230VAC, 1-phase, 50Hz
Cooling Water : laboratory mains supply
Chemicals : binary mixture (e.g. methanol-
water)
Analytical Equipment : GC or Refractometer for
sample analysis
OVERALL DIMENSIONS
Height : 2.00 m
Width : 1.22 m
Depth : 0.61 m
MANUAL
The unit comes with Operating and Experimental
manuals in English.
TRAINING
Training will be conducted to handing over of the
unit.
Our range of teaching equipment can be complemented with our
SOLDAS and SOLCAL software.
SOFTWARE & E - LEARNING
SOLDAS® - Supervisory Control & Data Acquisition
- Data Logging
- Signal Analysis
- Process Control
- Real-Time Display
- Tabulated Results
- Graph of Experimental Results
SOLCAL® - Computer Aided Learning
- Multimedia Features
- Interactive
- Graphic Simulation
- Experiment Result Samples
- Full Experiment Manuals
SOLTEQ®
Contact us for a catalog CD
SOLUTION ENGINEERING SDN. BHD.(Co. No. 174876-M)
Sales Office :
No.3, Jalan TPK 2/4, Taman Perindustrian Kinrara,47100 Puchong, Selangor Darul Ehsan, Malaysia.Tel. No. : +(603) 80758000
Fax. No.: +(603) 80755784
R&D Office :
G-2A, Incubator 3, Technology Park Malaysia,Bukit Jalil, 57000 Kuala Lumpur, Malaysia.Tel. No. : +(603) 8996 0023
Email : [email protected] site : http//www.solution.com.my/