VIRDI 3000 Installation Guide
Transcript of VIRDI 3000 Installation Guide
1Installation for V3000 V1.1Installation for V3000 V1.1
Installation Guide For VIRDI-3000 V1.1Fingerprint Identification System
Installation Guide Installation Guide For VIRDIFor VIRDI--3000 V1.13000 V1.1Fingerprint Identification SystemFingerprint Identification System
Union community Co., Ltd.Union community Co., Ltd.
Version 1.1Mar.,20.2007
Version 1.1Version 1.1Mar.,20.2007Mar.,20.2007
2Installation for V3000 V1.1Installation for V3000 V1.1
J203DoorLockInterface
J251PowerAdapter
J301InterphoneInterface
Voice(-)
Voice(+)
J501NetworkInterface(UTP)
FGND (GR) - 3GND (BK) - 2+12V (RE) - 1
GND (BK) - 8
Door Monitor2 (BL) - 7
Door Monitor1 (GR) - 6
Door Monitor0 (YE) - 5
Inside Open (OR) - 4
Lock GND (BK) - 3
Lock Out 2 (RE) - 2
Lock Out 1 (BR) - 1
D - 8
D - 7
D - 6
D - 5
D - 4
D - 3
D - 2
D - 1
P - 3
P - 2
P - 1
D - 2
D - 1
1. External Connectors1. External Connectors
3Installation for V3000 V1.1Installation for V3000 V1.1
S1
S2
RED
Black
(Door Open)
(Door Open)
1
2
Pin4(Orange)
Pin8(Black)
2. Connecting Door phone2. Connecting Door phone
4Installation for V3000 V1.1Installation for V3000 V1.1
Switch Hub or Hub
UTP 10Base-T
3. Connecting Ethernet (LAN) Cable3. Connecting Ethernet (LAN) Cable
** UTP Connector
5Installation for V3000 V1.1Installation for V3000 V1.1
J301 Door Phone Cable
J203 Lock Interface CableJ251 DC Power Input
Fuse
SW202SW203SW201SW204
J501 Ethernet Interface
SW1 Reset Switch
J151 Fingerprint Sensor
RV201 Audio Volume Control
J105 Wiegand Out Interface
J106 Wiegand IN Interface
J252DC5V Output
RS-232 Serial Port
SW101 RS232 Level Select
SW205 Lock Mode Select
SW102 RS-485 Termination Resistor Select Switch
232TTL: Inside RF/Smart Card ModuleRS232 : Using J103 RS232 Serial Port
J253DC Power Input Voltage
bypass Output
4. Main Board Feature4. Main Board Feature
6Installation for V3000 V1.1Installation for V3000 V1.1
LM_NC
PV201A260LJT2
12
Lock OUT 2
VIN
LockCon2
SW201DJMM-12V
13
2
LockCon1
SW203DJMM-12V
13
2 PV202A260LJT2
12
NC
SW204DJMM-12V
13
2
D202M4
AK
D208M4
AK
Q203
KN2222AS
B
EC
Motor
5V
D201
M4
AK
DC206
104C2
12
5V
Q204
KN2222AS
B
EC
R221473R
1 2
LM_COM2
PV210A260LJT2
12
D207
M4
AK
1.0mm
LM_COM1
SW202DJMM-12V
13
2
LM_COM2
AutoDoorK201G6S-2
910
8
43
5112
AutoDoor
R237102R
1 2
R238473R
1 2
R220102R
1 2
Motor/Strike
VIN
DC216
104C2
12
LM_NO
AutoDoor
Auto Door
Strike
Lock OUT 1
LM_COM1Strike/MT
Motor
K203G6S-29
10
8
43
5112PV209
A260LJT2
12
NO
5. Schematic for Door Lock Interface 5. Schematic for Door Lock Interface
7Installation for V3000 V1.1Installation for V3000 V1.1
ON
WnP
12 3 4
- C +
(-)Black
(+)Red
Door MonitorPin5
Pin1
Inside Door Open S/W
StrikeMotor
AutoDoor
Lock Type Select S/W
D - 8D - 7D - 6D - 5D - 4D - 3D - 2D - 1
GND(BK)-8DOOR MONITOR2(BL)-7DOOR MONITOR1(GR)-6DOOR MONITOR0(YE)-5
INSIDE OPEN(OR)-4LOCK GND(BK)-3
LOCK OUT 2(RE)-2LOCK OUT 1(BR)-1
SW204
NC
MotorNO
Pin4Pin3
Pin8
SW201 SW203 SW202
MotorAutoDoor
Strike StrikeMotor
SW205
Moto
r
Strik
e
N.C
Ext-
Lock
N.O
In-Lock
6.1. Connect with one system & one Lock
6. Connecting Dead6. Connecting Dead--Bolt Type Door Lock(Fail Safe) Bolt Type Door Lock(Fail Safe)
8Installation for V3000 V1.1Installation for V3000 V1.1
6. Connecting Dead6. Connecting Dead--Bolt Type Door Lock ( Fail Safe )Bolt Type Door Lock ( Fail Safe )
6.2. Connect with two system & one Lock
ON
WnP
12 3 4
- C +
(-)Black
(+)Red
Door Monitor
Pin3
Pin1
Pin5
Pin1
Pin5
Pin2
Pin8
D - 8D - 7D - 6D - 5D - 4D - 3D - 2D - 1
GND(BK)-8DOOR MONITOR2(BL)-7DOOR MONITOR1(GR)-6DOOR MONITOR0(YE)-5
INSIDE OPEN(OR)-4LOCK GND(BK)-3
LOCK OUT 2(RE)-2LOCK OUT 1(BR)-1
D - 8D - 7D - 6D - 5D - 4D - 3D - 2D - 1
GND(BK)-8DOOR MONITOR2(BL)-7DOOR MONITOR1(GR)-6DOOR MONITOR0(YE)-5
INSIDE OPEN(OR)-4LOCK GND(BK)-3
LOCK OUT 2(RE)-2LOCK OUT 1(BR)-1
System 2
System 1
StrikeMotor
AutoDoor
Lock Type Select S/W
SW204
NC
MotorNO
SW201 SW203 SW202
MotorAutoDoor
Strike StrikeMotor
SW205
Moto
r
Strik
e
N.C
Ext-
Lock
N.O
In-Lock
StrikeMotor
AutoDoor
Lock Type Select S/W
SW204
NC
MotorNO
SW201 SW203 SW202
MotorAutoDoor
Strike StrikeMotor
SW205
Moto
r
Strik
e
N.C
Ext-
Lock
N.O
In-Lock
System 2System 1
9Installation for V3000 V1.1Installation for V3000 V1.1
7. Connecting Strike Type Door Lock ( Fail Safe )7. Connecting Strike Type Door Lock ( Fail Safe )
7.1. Connect with one system & one Lock
(-)Black
(+)Red
Inside Door Open S/W
Door MonitorPin5
Pin1
D - 8D - 7D - 6D - 5D - 4D - 3D - 2D - 1
GND(BK)-8DOOR MONITOR2(BL)-7DOOR MONITOR1(GR)-6DOOR MONITOR0(YE)-5
INSIDE OPEN(OR)-4LOCK GND(BK)-3
LOCK OUT 2(RE)-2LOCK OUT 1(BR)-1
Pin4Pin3
Pin8
StrikeMotor
AutoDoor
Lock Type Select S/W
SW204
NC
MotorNO
SW201 SW203 SW202
MotorAutoDoor
Strike StrikeMotor
SW205
Moto
r
Strik
e
N.C
Ext-
Lock
N.O
In-Lock
10Installation for V3000 V1.1Installation for V3000 V1.1
7. Connecting Strike Type Door Lock ( Fail Safe )7. Connecting Strike Type Door Lock ( Fail Safe )
7.2. Connect with two system & one Lock
(-)Black
(+)Red
Door Monitor
Pin3
Pin1
Pin5
Pin1
Pin5
Pin2
Pin8
D - 8D - 7D - 6D - 5D - 4D - 3D - 2D - 1
GND(BK)-8DOOR MONITOR2(BL)-7DOOR MONITOR1(GR)-6DOOR MONITOR0(YE)-5
INSIDE OPEN(OR)-4LOCK GND(BK)-3
LOCK OUT 2(RE)-2LOCK OUT 1(BR)-1
D - 8D - 7D - 6D - 5D - 4D - 3D - 2D - 1
GND(BK)-8DOOR MONITOR2(BL)-7DOOR MONITOR1(GR)-6DOOR MONITOR0(YE)-5
INSIDE OPEN(OR)-4LOCK GND(BK)-3
LOCK OUT 2(RE)-2LOCK OUT 1(BR)-1
System 2
System 1
StrikeMotor
AutoDoor
Lock Type Select S/W
SW204
NC
MotorNO
SW201 SW203 SW202
MotorAutoDoor
Strike StrikeMotor
SW205
Moto
r
Strik
e
N.C
Ext-
Lock
N.O
In-Lock
StrikeMotor
AutoDoor
Lock Type Select S/W
SW204
NC
MotorNO
SW201 SW203 SW202
MotorAutoDoor
Strike StrikeMotor
SW205
Moto
rStrik
e
N.C
Ext-
Lock
N.O
In-Lock
System 2System 1
11Installation for V3000 V1.1Installation for V3000 V1.1
(-)Black
(+)Red
Inside Door Open S/W
Door MonitorPin5
Pin1
D - 8D - 7D - 6D - 5D - 4D - 3D - 2D - 1
GND(BK)-8DOOR MONITOR2(BL)-7DOOR MONITOR1(GR)-6DOOR MONITOR0(YE)-5
INSIDE OPEN(OR)-4LOCK GND(BK)-3
LOCK OUT 2(RE)-2LOCK OUT 1(BR)-1
Pin4Pin3
Pin8
StrikeMotor
AutoDoor
Lock Type Select S/W
SW204
NC
MotorNO
SW201 SW203 SW202
MotorAutoDoor
Strike StrikeMotor
SW205
Moto
r
Strik
e
N.C
Ext-
Lock
N.O
In-Lock
8. Connecting Strike Type Door Lock ( Fail Secure )8. Connecting Strike Type Door Lock ( Fail Secure )
8.1. Connect with one system & one Lock
12Installation for V3000 V1.1Installation for V3000 V1.1
8. Connecting Strike Type Door Lock ( Fail Secure )8. Connecting Strike Type Door Lock ( Fail Secure )
8.2. Connect with two system & one Lock
Door Monitor
Pin3
Pin1
Pin5
Pin1
Pin5
Pin3
D - 8D - 7D - 6D - 5D - 4D - 3D - 2D - 1
GND(BK)-8DOOR MONITOR2(BL)-7DOOR MONITOR1(GR)-6DOOR MONITOR0(YE)-5
INSIDE OPEN(OR)-4LOCK GND(BK)-3
LOCK OUT 2(RE)-2LOCK OUT 1(BR)-1
D - 8D - 7D - 6D - 5D - 4D - 3D - 2D - 1
GND(BK)-8DOOR MONITOR2(BL)-7DOOR MONITOR1(GR)-6DOOR MONITOR0(YE)-5
INSIDE OPEN(OR)-4LOCK GND(BK)-3
LOCK OUT 2(RE)-2LOCK OUT 1(BR)-1
System 2
System 1
(-)Black
(+)Red
StrikeMotor
AutoDoor
Lock Type Select S/W
SW204
NC
MotorNO
SW201 SW203 SW202
MotorAutoDoor
Strike StrikeMotor
SW205
Moto
r
Strik
e
N.C
Ext-
Lock
N.O
In-Lock
StrikeMotor
AutoDoor
Lock Type Select S/W
SW204
NC
MotorNO
SW201 SW203 SW202
MotorAutoDoor
Strike StrikeMotor
SW205
Moto
r
Strik
e
N.C
Ext-
Lock
N.O
In-Lock
System 2System 1
13Installation for V3000 V1.1Installation for V3000 V1.1
(-)Black(+)Red
Inside Door Open S/W
Door MonitorPin5
Pin1
D - 8D - 7D - 6D - 5D - 4D - 3D - 2D - 1
GND(BK)-8DOOR MONITOR2(BL)-7DOOR MONITOR1(GR)-6DOOR MONITOR0(YE)-5
INSIDE OPEN(OR)-4LOCK GND(BK)-3
LOCK OUT 2(RE)-2LOCK OUT 1(BR)-1
Pin4Pin3
Pin8
StrikeMotor
AutoDoor
Lock Type Select S/W
SW204
NC
MotorNO
SW201 SW203 SW202
MotorAutoDoor
Strike StrikeMotor
SW205
Moto
r
Strik
e
N.C
Ext-
Lock
N.O
In-Lock
9. Connecting EM Type Door Lock ( Fail Safe )9. Connecting EM Type Door Lock ( Fail Safe )
9.1. Connect with one system & one Lock
14Installation for V3000 V1.1Installation for V3000 V1.1
- (Black)
+ (Red)
Door Monitor
Lock(+)
Inside Door Open S/W
Lock(-)
Pin1
Pin2
Pin4Pin5
Pin8
12V 3AAdapter
(+)
(-)
Lock 1
Lock 2
9. Connecting EM Type Door Lock ( Fail Safe )9. Connecting EM Type Door Lock ( Fail Safe )
9.2. Connect with one system & two Lock ** Use external DC Power Adapter
StrikeMotor
AutoDoor
Lock Type Select S/W
SW204
NC
MotorNO
SW201 SW203 SW202
MotorAutoDoor
Strike StrikeMotor
SW205
Moto
r
Strik
e
N.C
Ext-
Lock
N.O
In-Lock
D - 8D - 7D - 6D - 5D - 4D - 3D - 2D - 1
GND(BK)-8DOOR MONITOR2(BL)-7DOOR MONITOR1(GR)-6DOOR MONITOR0(YE)-5
INSIDE OPEN(OR)-4LOCK GND(BK)-3
LOCK OUT 2(RE)-2LOCK OUT 1(BR)-1
15Installation for V3000 V1.1Installation for V3000 V1.1
Inside Door Open S/W
Auto Door Operating PartAuto Door Motor
Sensor Input Line
9P CONN
Auto-Door Sensor Auto-Door Monitor
Pin1
D - 8D - 7D - 6D - 5D - 4D - 3D - 2D - 1
GND(BK)-8DOOR MONITOR2(BL)-7DOOR MONITOR1(GR)-6DOOR MONITOR0(YE)-5
INSIDE OPEN(OR)-4LOCK GND(BK)-3
LOCK OUT 2(RE)-2LOCK OUT 1(BR)-1
Pin2
StrikeMotor
AutoDoor
Lock Type Select S/W
SW204
NC
MotorNO
SW201 SW203 SW202
MotorAutoDoor
Strike StrikeMotor
SW205
Moto
r
Strik
e
N.C
Ext-
Lock
N.O
In-Lock
10. Connecting Auto Door ( Contact Control )10. Connecting Auto Door ( Contact Control )
10.1. Connect with one system & one Lock
16Installation for V3000 V1.1Installation for V3000 V1.1
Sensor Input Line
9P CONN
Auto-Door Sensor Auto-Door Monitor
Pin2
Pin1
Pin1
Pin2
D - 8D - 7D - 6D - 5D - 4D - 3D - 2D - 1
GND(BK)-8DOOR MONITOR2(BL)-7DOOR MONITOR1(GR)-6DOOR MONITOR0(YE)-5
INSIDE OPEN(OR)-4LOCK GND(BK)-3
LOCK OUT 2(RE)-2LOCK OUT 1(BR)-1
D - 8D - 7D - 6D - 5D - 4D - 3D - 2D - 1
GND(BK)-8DOOR MONITOR2(BL)-7DOOR MONITOR1(GR)-6DOOR MONITOR0(YE)-5
INSIDE OPEN(OR)-4LOCK GND(BK)-3
LOCK OUT 2(RE)-2LOCK OUT 1(BR)-1
System 2
System 1
Auto Door Operating Part Auto Door Motor
StrikeMotor
AutoDoor
Lock Type Select S/W
SW204
NC
MotorNO
SW201 SW203 SW202
MotorAutoDoor
Strike StrikeMotor
SW205
Moto
r
Strik
e
N.C
Ext-
Lock
N.O
In-Lock
StrikeMotor
AutoDoor
Lock Type Select S/W
SW204
NC
MotorNO
SW201 SW203 SW202
MotorAutoDoor
Strike StrikeMotor
SW205
Moto
r
Strik
e
N.C
Ext-
Lock
N.O
In-Lock
System 2System 1
10. Connecting Auto Door ( Contact Control )10. Connecting Auto Door ( Contact Control )
10.2. Connect with two system & one Lock
17Installation for V3000 V1.1Installation for V3000 V1.1
BlueBrownWhiteOrangeYellowBlackRED
Door Monitor
Inside Door Open S/W
Unlock Signal
Motor 1Motor 2Ground
StrikeMotor
AutoDoor
Lock Type Select S/W
SW204
NC
MotorNO
SW201 SW203 SW202
MotorAutoDoor
Strike StrikeMotor
SW205
Moto
r
Strik
e
N.C
Ext-
Lock
N.O
In-Lock
Pin4
Pin1
D - 8D - 7D - 6D - 5D - 4D - 3D - 2D - 1
GND(BK)-8DOOR MONITOR2(BL)-7DOOR MONITOR1(GR)-6DOOR MONITOR0(YE)-5
INSIDE OPEN(OR)-4LOCK GND(BK)-3
LOCK OUT 2(RE)-2LOCK OUT 1(BR)-1
Pin3Pin2
Pin8
Pin5Locking Signal
Pin7Pin6
Ground
11. Connecting Motor Lock 11. Connecting Motor Lock
18Installation for V3000 V1.1Installation for V3000 V1.1
12. Connecting 2 Emergency Lamps 12. Connecting 2 Emergency Lamps
12 V (+) Ground (-) Ground (-)12 V (+)
EmergencyLamp 1
EmergencyLamp 2
Pin1
D - 8D - 7D - 6D - 5D - 4D - 3D - 2D - 1
GND(BK)-8DOOR MONITOR2(BL)-7DOOR MONITOR1(GR)-6DOOR MONITOR0(YE)-5
INSIDE OPEN(OR)-4LOCK GND(BK)-3
LOCK OUT 2(RE)-2LOCK OUT 1(BR)-1
Pin2Pin3
StrikeMotor
AutoDoor
Lock Type Select S/W
SW204
NC
MotorNO
SW201 SW203 SW202
MotorAutoDoor
Strike StrikeMotor
SW205
Moto
r
Strik
e
N.C
Ext-
Lock
N.O
In-Lock