Viking Pump Nozzle Load Details
Click here to load reader
-
Upload
tushar-naik -
Category
Documents
-
view
170 -
download
16
description
Transcript of Viking Pump Nozzle Load Details
-
TECHNICAL REFERENCE
TR NO. TR-100 PAGE: REVISION: F REV. DATE: 30 Dec 2013
TITLE: Allowable Nozzle Loading (Forces & Moments)
VIKING PUMP, INC. A Unit of IDEX Corporation Cedar Falls, IA 50613 U.S.A.
8
Series 724, 4724
(4724 PUMP SHOWN IN DRAWING) LOADING COORDINATE SYSTEM: X: PARALLEL TO PUMP SHAFT Y: VERTICAL, PERPENDICULAR TO PUMP SHAFT Z: HORIZONTAL, PERPENDICULAR TO PUMP SHAFT
P: FORCES (LBF / N) M: MOMENTS (FT-LBF / N-m)
PUMP SIZE (FLANGE SIZE)
PORT A
PORT B
Px Py Pz Mx My Mz Px Py Pz Mx My Mz
F (0.5) &FH8,9 (0.75) 100 445 105 465
120 535
25 35
10 14
25 35
100 445
105 465
120 535
25 35
10 14
25 35
G8,9 (1) 85
375 95
420 120 535
25 35
10 14
25 35
85 375
95 420
120 535
25 35
10 14
25 35
H&HL9 (1.5) 360 1600 360
1600 360
1600 230 300
90 120
25 35
360 1600
360 1600
360 1600
230 300
25 35
90 120
K,KK&L9 (2) 420 1870 420
1870 420 1870
440 600
150 200
50 70
420 1870
420 1870
420 1870
440 600
50 70
150 200
LQ (2.5) &LL (3) 450 1950 450
1950 450 1950
485 650
195 260
220 300
450 1950
450 1950
450 1950
485 650
195 260
220 300
8Pump has opposite ports. Port B is directly opposite Port A. 9Pumps have tapped ports
UmeshHighlight