Vijeo Look SCADA software for small and medium-sized … Documents/PLC... · 2002. 6. 10. · Vijeo...
Transcript of Vijeo Look SCADA software for small and medium-sized … Documents/PLC... · 2002. 6. 10. · Vijeo...
-
Vijeo LookSCADA software for small andmedium-sized supervisionapplications.
Vijeo Look Eng
-
2
-
Table of Contents
About the book . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Chapter 1 General overview of Vijeo Look . . . . . . . . . . . . . . . . . . . . . . . . . 7Presentation of the Human Machine Interface (HMI) . . . . . . . . . . . . . . . . . . . . . . 7
Chapter 2 Installing the product Vijeo Look . . . . . . . . . . . . . . . . . . . . . . . . 9At a Glance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Installation of Vijeo Look and its different components . . . . . . . . . . . . . . . . . . . . 10Uninstalling Vijeo Look and its different components . . . . . . . . . . . . . . . . . . . . . 13License management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14Vijeo Look Registration Request . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16Vijeo Look Upgrade Registration Request . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Chapter 3 Main functions of Vijeo Look. . . . . . . . . . . . . . . . . . . . . . . . . . .19At a Glance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19The main tools of Vijeo Look. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20Description of the main functions of the "Insert" menu . . . . . . . . . . . . . . . . . . . . 22Description of the main functions of the "Tools/Application/Configuration Explorer"menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Chapter 4 Reminder about the OFS configuration tool . . . . . . . . . . . . . . 25Reminder about editing aliases. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Chapter 5 Start-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29At a Glance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29Creating a project . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30Detailed explanations of some parts of the demonstration project . . . . . . . . . . . 31Creating part of the "manufacture" synoptic . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32Creating part of the "purification" synoptic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35Inserting an ActiveX and a Bean component . . . . . . . . . . . . . . . . . . . . . . . . . . . 40Writing a variable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
3
-
4
-
About the book
At a Glance
Document Scope This manual describes how to get started with the Vijeo Look software
User Comments We welcome your comments about this document. You can reach us by e-mail [email protected]
Vijeo Look 5
-
About the book
6 VijeoLook
-
Vijeo Look
1
General overview of Vijeo Look
Presentation of the Human Machine Interface (HMI)
General Vijeo Look is a HMI (Human Machine Interface) application. It is operated usingWindows 98, Windows ME, Windows NT4 SP6 and Windows 2000.The minimum configuration required is a Celeron 566Mhz with 128 Mb of RAM.Vijeo Look supplies all that is necessary for data acquisition, as well as for thedevelopment and visualization of animated synoptics for running PC processes.Real time data acquisition is performed using the OPC Factory Server (OFS)communications server, included in the product.
Illustration using an automated line command:Vijeo Look
Grid
Shades
Textures
Speed (ms)
Grid
Shade
Textures
0
100
200
300
400500
Cars painted
Red
Blue
Green
Yellow
03
03
00
00
00
Configuration
Auto
Red
27/08/2001 08:54:52:550 Alarm on - not ack Device 1. Default0127/08/2001 08:54:53:742 Alarm on - not ack Device 1. Default01
Administrator 1 Manufacturing 27/08/01 08:51:03
Configuration of the ani...
7
-
General overview of Vijeo Look
Using a simple graphic object, it is possible to visualize and /or command a motor,robot or other device by associating it with one or more variables.
The main features of the product are:� an advanced graphic motor, comprising:
� libraries of graphic objects that may be configured by the user,� editor of advanced native graphic elements,� management of CAD type calques,� unlimited synoptic size,� 24 bit color support,� import of images and animations in BMP, JPEG, GIF, AVI, EMF, and WMF
formats� Zoom function,
� many types of animations,� flexible configuration of user rights,� activeX container,� VBA motor,� Java Bean container,� real time data logging tool,� interface available in English, French, German or Spanish.
8 VijeoLook
-
Vijeo Look
2
Installing the product Vijeo Look
At a Glance
Subject of thisChapter
The aim of this chapter is to describe how to install the different components of VijeoLook.
What's in thisChapter?
This Chapter contains the following Maps:
Topic Page
Installation of Vijeo Look and its different components 10
Uninstalling Vijeo Look and its different components 13
License management 14
Vijeo Look Registration Request 16
Vijeo Look Upgrade Registration Request 17
9
-
Installing the product Vijeo Look
Installation of Vijeo Look and its different components
At a Glance The product is available in CD-ROM format including the installation of Vijeo Lookand OPC Factory Server, Visual Basic Application, Java virtual machine, MSDE,LapLink Gold and the communications driver Uni-telway.
Illustration The figure below shows the welcome page of Vijeo Look Setup:
Note: Before performing a reinstallation, users are advised to perform adeinstallation (See Uninstalling Vijeo Look and its different components, p. 13)
Vijeo Look
< Previous Next > Cancel
Welcome to Vijeo Look Installshield Wizard.
The InstallShield Wizard will set up Vijeo Look on yourcomputer. To continue click on Next.
10 VijeoLook
-
Installing the product Vijeo Look
Installing theproduct
To install Vijeo Look and its components, open the file Setup.exeDescription of the different installation stages:
Example using the setup of "LapLink driver":
1 Selecting theinstallation language
Select the required setup language:� German,� English,� Spanish,� French (standard).
2 License contract If you accept the contract terms, go to the next page.
3 Client information To customize the software you must enter the followinginformation:� User name,� Company name.
4 Languages Select the two languages you wish to use as well as the oneto be used by default in the application
5 Setup type Select the setup type which best suits your needs:� By default,� Compact (with setup of the demonstration project or the
shared libraries),� Customized (allows user to choose the target directory
as well as some options in the setup)
Vijeo Look
< Previous Next > Cancel
Select the componentsChoose the components that the setup assistant will install.
Select the components to be set up, and remove the components that are not to be installed.
ProgramsDemonstration ProjectsOn line help
English
Description
This component enablesMSDE to be set up.
InstallShield
Space necessary inSpace available in
FrenchGermanSpanish
Documentation
EnglishFrench
MSDE,
C: 90027 KC: 434902 K
Vijeo Look 11
-
Installing the product Vijeo Look
Description of the different installation stages:
The installshield is installing Vijeo Look and the other components you haveselected.The installshield installs OPC Factory Server by default, followed consecutively byMSDE, Visual Basic Application, Vijeo Look, then Java Runtime and the Uni-telwaycommunication driver.
6 Select a programfolder
The setup assistant adds the program icons to thechosen program folder (Modicon Telemecanique bydefault). The assistant creates a "ModiconTelemecanique" sub-folder by default, called "VijeoLook", in which all the tools associated with the productcan be found.
7 Launch installation Recheck the configuration of parameters beforelaunching the installation.
8 Installing theUni-telway driver
Once all the components of Vijeo Look have beeninstalled, the installshield will ask you to configure theinstallation of the Uni-telway driver.
Note: When installation is complete, do not forget to restart your computer toensure all the installed components have been taken into account.
12 VijeoLook
-
Installing the product Vijeo Look
Uninstalling Vijeo Look and its different components
Description
To uninstall Vijeo Look and the other components, proceed as follows:� uninstall, using the "Add/Remove programs" command in the "Control Panel", the
following programs:� Java Runtime Environment,� OFS Configuration tool,� OPC Factory Server� Uni-telway,� XWAY,� Vijeo Look,� MSDE,� Laplink (if set up).
� switch your machine on again.
Note: Before uninstalling Vijeo Look, it is vital to first transfer the softwareprotections to another computer (see Transferring protections, p. 15), otherwiseit will be no longer possible to continue using Vijeo Look.
Vijeo Look 13
-
Installing the product Vijeo Look
License management
Description When setting up Vijeo Look you have 21 days to request your license fromSchneider Automation.
During these 21 days the status of your software is "Unauthorized" and remains sountil entry of the permanent authorization code provided by Schneider Automation.
Reminder:� once installed, it is necessary to obtain a definitive license,� once this license has been obtained, it is possible to transfer the license to
another work station,� if you purchase a later version of Vijeo Look, a simple update is all that is
necessary.
To obtain yourlicense
During the first launch of Vijeo Look, you are asked to enter the "serial number" and"reference number" so that a work station may be identified in order to obtain yourlicense.To obtain the permanent code of the software:
Note: Once the license has been obtained, it is possible to transfer the license toanother work station (see below).
Step Action
1 Enter the serial number and reference number, then click "Next". TheCopyControl program generates a setup code.
2 You can generate the demand file now or later.
3 Correctly fill in all the information requested, then click "Next".
4 Send this document by Fax or by E-mail to receive the permanentauthorization code.
14 VijeoLook
-
Installing the product Vijeo Look
Performing anupdate.
There are 6 different packages for Vijeo Look:� "buildtime/runtime" 128 I/O, for a single OFS server,� "buildtime/runtime" 512 I/O, for a single OFS server,� "buildtime/runtime" 1024 I/O, for all OPC servers,� "runtime" 128 I/O, for a single OFS server,� "runtime" 256 I/O, for a single OFS server,� "runtime" 1024 I/O, for all OPC servers,
When you purchase Vijeo Look, you can ask for an update in order to have more I/Os.For this, you must purchase the corresponding commercial reference, then, onreceipt of the order, create a license demand as for a first purchase. For an update,the definitive version will only be effective on receipt of the definitive code issued bySchneider.
Transferringprotections
It is possible to set up Vijeo Look on several machines; however, once a protectionis transferred, Vijeo Look will only be active on the machine possessing the softwareprotections.
It is therefore possible to transfer a protection from one machine to another asfollows (example of a transfer from machine A, in which the permanent authorizationcode is found, to machine B):� after setup on machine B, note the generated code,� on machine A, click "Protection transfer" in the main menu,� enter and confirm the setup code of machine B,� click "Recover the authorization code" to validate the transfer, the license of
machine A is rendered invalid and a new code is generated for machine B.
Vijeo Look 15
-
Installing the product Vijeo Look
Vijeo Look Registration Request
Information DATE:
-----------------------------------
SERIAL NUMBER:
REFERENCE NUMBER:
INSTALLATION CODE:
UPDATE NUMBER:
-----------------------------------
COMPANY NAME :
CONTACT NAME :
ADDRESS :
CITY :
ZIP CODE :
STATE :
COUNTRY :
EMAIL :
PHONE :
FAX :
[ Stick the product label here ]
16 VijeoLook
-
Installing the product Vijeo Look
Vijeo Look Upgrade Registration Request
Information DATE:
-----------------------------------
SERIAL NUMBER:
REFERENCE NUMBER:
INSTALLATION CODE:
UPDATE NUMBER:
-----------------------------------
COMPANY NAME :
CONTACT NAME :
ADDRESS :
CITY :
ZIP CODE :
STATE :
COUNTRY :
EMAIL :
PHONE :
FAX :
-----------------------------------
PREVIOUS SERIAL NUMBER :
PREVIOUS REFERENCE NUMBER :
[ Stick the product label here ]
Vijeo Look 17
-
Installing the product Vijeo Look
18 VijeoLook
-
Vijeo Look
3
Main functions of Vijeo Look
At a Glance
Subject of thisChapter
This chapter describes the main functions available in the synoptics of Vijeo Look.
What's in thisChapter?
This Chapter contains the following Maps:
Topic Page
The main tools of Vijeo Look 20
Description of the main functions of the "Insert" menu 22
Description of the main functions of the "Tools/Application/ConfigurationExplorer" menu
24
19
-
Functions of Vijeo Look
The main tools of Vijeo Look
At a Glance The main tools of Vijeo Look are concentrated on the Visual Basic softwareapplication, the ActiveX and Beans Components, trend curves, viewers and databases.Description of the main tools:
Menu Submenu Description
Display Visual Basic editor This link with Visual Basic is used to developscripts.
Insert ActiveX Control Allows ActiveX controls to be inserted in asynoptic.It should be noted that the ActiveX controlsshown in this field must be pre-selected in themenu (see Tools/Ergonomics/ActiveX Controls).
Insert Bean component Allows a Bean component to be inserted in asynoptic.Unlike the ActiveX Controls, all Beancomponents shown in the Project are displayedwithout pre-selection.
Insert Trend curves Enable analog data to be visualized in trendcurve form.
Insert Alarm window Displays the status of alarms in real time.
Insert Log window Displays archived data.
Draw Allows synoptics to be drawn using nativegraphic elements.
Animation Allows the graphic elements of a synoptic to beanimated according to real time variables.
Tools Application � access to the OFS configuration via theconfiguration tool,
� access to the Vijeo Look configuration tool(configuration tool of the log server, dataserver, etc.).
File Edit Display Insert Drawing Order Animation Mode Tools Window ?
Display
Insert
Insert
Insert
Insert
Insert
Draw
Animation
Tools
20 VijeoLook
-
Functions of Vijeo Look
Tools Project Enables an existing project to be opened, a newproject to be created and to restore/archive aproject.
Menu Submenu Description
Tools
Vijeo Look 21
-
Functions of Vijeo Look
Description of the main functions of the "Insert" menu
ActiveX The ActiveX are objects that can be easily programmed using Visual Basic forApplication. You can for example insert the ActiveX "Microsoft Web Browser" inorder to display an HTML page (see Example of inserting an ActiveX, p. 40).
Bean component Bean components are objects (like the ActiveX) used to send back data supplied byPLC variables (see Example of inserting a Bean component, p. 41).We can for example display the rotation value of a motor using an analog measuringdevice.Some examples of Bean Components:
Trend curves The trend curve is used to display in graphic form the evolution over time of one ormore variables. Several trend curves can be concatenated in a synoptic, the onlylimitation being the size of the physical space available.It is also possible to insert several "Trend curve" windows into the same synoptic.Illustration:
Measurement devices Switch
14:13:20 14:13:30 14:13:40 14
22 VijeoLook
-
Functions of Vijeo Look
The main characteristics of the trend curves are:� up to eight registers and/or bits can be displayed for each log,� Log and Real Time modes,� the coordinate axis (amplitude) is configurable for each "Trend curve" window,� the abscissa axis (time) is configurable between 1 second and 32767 days,� zoom functions,� an unlimited number of log displays per project.
Alarm window The alarm Viewer is an ActiveX that displays the status of the alarms. Several alarmViewers can be created in the one synoptic, the only limitation being the size of thephysical space available.Illustration:
The main characteristics of the alarm Viewers are:� an unlimited number of alarm Viewers in each project,� the format of the alarm text is totally configurable.
Log window The Log Viewer is an ActiveX control which displays the data saved in the data base.It is possible to display all the data or, by using filters, to display only a part of thedata. Several Log Viewers can be inserted into a synoptic, the only limitation beingthe size of the physical space available.
The main characteristics of the Log Viewer are:� an unlimited number of Log Viewers for each project,� for each Log Viewer, one or more filters can be created,� Display:
� change in an alarm's status,� change in a bit's status,� change in a word's value.
Date Hour Title Name24/08/01 10:36:25:532 Alarm on - not ack Device1.Default0124/08/01 10:36:25:532 Alarm on - not ack Device1.Default01
Vijeo Look 23
-
Functions of Vijeo Look
Description of the main functions of the "Tools/Application/ConfigurationExplorer" menu
General Certain "Configuration explorer" tabs appear only if the "Advanced parameters"option is selected from the "Display" menu of "Configuration explorer".
Generalparameters
Using the general parameters, we can configure:� the filters,� the association of tags,� the properties of variables,� the property ranges of variables,
Log server The log data server collects and saves data in real time from the Real Time DataServer. The trend and log viewers display the logged data.
This version of the software is qualified to use the following standard data bases:� Access 2000,� MSDE (Microsoft Data Exchange).
Data server The data server is used to create and to set up the variables (bit, register, text) to beused in synoptics and/or archived.It is also used to enhance the properties of variables by adding user parameters.Illustration:
Configuration Explorer
General parametersLog serverData server
OPC server
File Display
VariablesOFS
Name
Variable Properties Verbose properties
Associated label
Type
Internal
External
Server name
Type of Data Type
Trend
HMI accessAlarm
Logging
Options
Ready
24 VijeoLook
-
Vijeo Look
4
Reminder about the OFSconfiguration tool
Reminder about editing aliases
Definition An alias is a variable used by OFS whose properties include a name, acommunication protocol and a table of symbols file (this last property beingoptional).
Creating an alias Aliases are edited using the OFS configuration tool, named "OFSconf.exa", which isfound in: ...\Ofs\OFSconf\OFSconf.exe.The OFS Configuration Tool main window shows the aliases listed in a grid, the"Server Mode" option and the "Group Min Update Rate". This data covers mostuser requirements.
Note: Vijeo Look is preconfigured with OFS. Several aliases have been created forthe operation of the demonstration project.
25
-
Reminder about creating aliases
Illustration:
The table below describes the fields of the above screen:
OFS Configuration
Welcome to the OPC Factory Server Configuration tool
200
2 11/10/01
Properties ofms
Group Min Update Rate
Server modeHiddenControlDiagnosticVerbose Diag.
List of PLC aliases
Building
Device1
Device2
Device3
UNTLW01:1.2.0
UNTLW01:0.254.0
UNTLW01:1.3.0
MBT:1.2.3.4
Name : Symbols table file
Server Edit ?Print
???
Advanced...
aliases
Number of aliases: 8
4
Ok Cancel Apply
Food_Beverage UNTLW01:1.4.0
Alias
Description
C:\Program Files\Modicon Telemecanique\Vijeo Look\Projects\Demo\OFS Files\Building.csv
MachinesManufacturing
WaterPlant
UNTLW01:1.50UNTLW01:1.6.0
UNTLW01:1.7.0
C:\Program Files\Modicon Telemecanique\Vijeo Look\Projects\Demo\OFS Files\Device1.csvC:\Program Files\Modicon Telemecanique\Vijeo Look\Projects\Demo\OFS Files\Device2.csv
C:\Program Files\Modicon Telemecanique\Vijeo Look\Projects\Demo\OFS Files\Device3.csv
C:\Program Files\Modicon Telemecanique\Vijeo Look\Projects\Demo\OFS Files\Food_Beverage.csv
C:\Program Files\Modicon Telemecanique\Vijeo Look\Projects\Demo\OFS Files\Machines.csvC:\Program Files\Modicon Telemecanique\Vijeo Look\Projects\Demo\OFS Files\Manufacturing.csv
C:\Program Files\Modicon Telemecanique\Vijeo Look\Projects\Demo\OFS Files\WaterPlant.csv
C:\Program Files\Modicon Telemecanique\OFS\Server\Ofs.exe
Server mode Hidden: the server is invisible on screen.Control: the server is iconized but only the system menu is accessible (rightmouse click).Diag. : a complete set of diagnostics windows is displayed during serverexecution, including a plotting window displaying warning and/or errormessages.Verbose diag.: the plotting window displays detailed information messagesin addition to errors and warnings. The rest is identical to "Diag." mode.
Group MinUpdate Rate
Minimum update rate allowed for groups. The update rate should be set bythe client as a multiple of this value. Numerical value in ms. Range:[10..32767]
"Advanced"button
Display seven additional tabs for experienced users.
Site name Here the user may enter up to 50 characters of text in order to identify theconfiguration of the aliases entered.This text appears at the top of the print file. If you make a back-up copy, it issaved in the chosen file. It does not figure in the configuration of the OFSserver.
OK Configuration validation and exiting the Configuration tool.
26 VijeoLook
-
Reminder about creating aliases
The aliases grid is made up of 3 columns which contain the most importantinformation on each device.
Creating an alias involves:� assigning a name,� defining the network address of the device, which includes the network driver and
the device address,� Providing a Symbols table file name (optional),� setting the alias properties which are related to how the server will behave
towards the variables created on that alias.These operations are all accessible via click-sensitive areas in the grid and the"Alias properties" button.
Sort function in the grid:
Apply Configuration validation without exiting the Configuration Tool.
Cancel Canceling modifications made since the Configuration tool was launched orsince the "Apply" button was activated.A confirmation request message is displayed.
Note: The information on the number of aliases declared is displayed. The "Createnew alias" and "Clear current alias" buttons allow an alias to be added to the gridand the selected alias to be deleted.
Note: Once an alias has been created, it is necessary to close and then reopen theOFS server to integrate any modifications made using the configuration tool.
CAUTION
Using the aliases
A device should be associated with a single and unique alias. If twoaliases point to the same device and are used simultaneously, thecommunication will malfunction. The properties will be the same forboth, and set to the properties of the alias first used to create an item.In the same way, using an alias and accessing the same device directlyfrom the address will have similar results.
Failure to observe this precaution can result in injury orequipment damage.
Vijeo Look 27
-
Reminder about creating aliases
The aliases can be arranged in the grid according to the parameters associated withthe alias:� Name of alias, driver, symbols table file. Simply click on the upper strip of the grid
in the appropriate column. Arrangement in alphabetical order.� Other parameters: activate the "Edit ->Sort" menu and select the parameter you
want. They are arranged alternately in increasing, or (by clicking again)decreasing order of values (e.g.: for a binary value parameter, increasingsignifies all the aliases with the value 0, then all those with the value 1).
Symbols tablefile
A symbols table file can be associated with the alias, in order to provide access tothe symbols for the variables of this device. The symbols file is generated by the PLCprogramming software, e.g. PL7 for Premium/Micro or Concept for Quantum.Clicking in the "Symbols table file" area for the selected alias in the grid brings up afile explorer:The file types that can be inserted are listed in the "type of files" list box. Select theappropriate file type.Enter the file of your choice and click "Open". The file name and directory will thenbe displayed in the grid.
28 VijeoLook
-
Vijeo Look
5
Start-up
At a Glance
Subject of thisChapter
The aim of this chapter is to help you with the realization of your projects. We shallexplain with the use of concrete examples how some of the demonstration projectblocks (delivered with the product) were created.
What's in thisChapter?
This Chapter contains the following Maps:
Topic Page
Creating a project 30
Detailed explanations of some parts of the demonstration project 31
Creating part of the "manufacture" synoptic 32
Creating part of the "purification" synoptic 35
Inserting an ActiveX and a Bean component 40
Writing a variable 42
29
-
Start-up
Creating a project
Description The following table describes the procedure to be followed to create, launch, andarchive your project:
Step Action
1 Before launching Vijeo Look, it is necessary to create all the aliases (SeeReminder about editing aliases, p. 25) of your project with the OFS configurationtool,� assign a name,� choose a network (MODBUS+, Uni-telway, etc.)� validate.If you have a symbol table (See Symbols table file, p. 28)file from PL7 or anothersoftware, you can assign it to the alias.
2 Once the alias has been created, it is necessary to configure and activate thecommunication driver (the Uni-telway driver is provided with the product).
3 Launch Vijeo Look.
4 In the "File" menu, click on "New". The window "New synoptic" will then bedisplayed. Click on OK to access your project.
5 In the "Tools" menu, click on "Application" then "Explorer configuration tool" toconfigure all your variables , alarms and logs.
6 You are now in Vijeo Look "Edit" mode: you can now create your synoptics.
7 Once your synoptic has been created, select "Execution" mode from the "Mode"menu to test it.
8 You can archive your project by clicking on the "Tool" menu, then "Project", andfinally "Archive/Restore".
30 VijeoLook
-
Start-up
Detailed explanations of some parts of the demonstration project
Description The Vijeo Look demonstration project is made up of 5 parts:� manufacturing,� purification,� complex machines,� agri-food� construction.Illustration:
In each synoptic there are buttons providing you with explanations on the creation of an animation or an object.
On the following pages you will find explanations which complete those associated of certain parts of the "demo".
File Edit Display Insert Drawing Order Animation Mode Tools Window ?Vijeo Look
Vijeo Look 31
-
Start-up
Creating part of the "manufacture" synoptic
GeneralDescription
In this demonstration project we can find two buttons (Alt + F1) that explain:� the creation of the tanks (button 1),� the creation of the painted cars counter (button 2).Illustration of the example:
Description ofthe "tank" part
This tank along with the bar-chart is composed of two grouped objects:� an image (bitmap),� a rectangle.
Inserting animage
To insert an image proceed as follows:
Note: To find out about the properties of a graphic object it is necessary to switchto "Edit" mode, then right click and select "Properties ...".
Cars painted
Red
Blue
Green
Yellow
Button 1 Button 2
Step Action
1 � Before launching Vijeo Look:� copy all your images (only bmp, jpeg, gif, avi, emf, and wmf) into c:\Program
Files\Modicon Telemecanique\Vijeo Look\Projects\"project name"\BitmapFiles,
� launch Vijeo Look.� in Vijeo Look, other predefined images can also be inserted by clicking "Tool",
then "Project" and "Libraries".
2 In the "File" menu, click "New". The window "New synoptic" will then be displayed.Click on OK to access your project.
3 In the "Insert" menu click "Image" then select and validate. The image is inserted.
32 VijeoLook
-
Start-up
Creating a barchart
To create a rectangle showing the level of the tank, proceed as follows:
Description ofthe counter part
We can the change the value of an object using the mathematical operator "=". Herewe add 4 internal variables, which correspond to the number of cars painted percolor.
Creating acounter
To create a counter showing the number of cars painted red (for example), proceedas follows:
Step Action
1 Before launching Vijeo Look:� create an alias (give a name, and define the network type) in the OFS
configuration tool (see Reminder about editing aliases, p. 25), then validate,� launch Vijeo Look.
2 In the "File" menu, click "New". The window "New synoptic" will then be displayed.Click on OK to access your project.
3 In the "Draw" menu create a rectangle.
4 Select the rectangle that is created and go to the "Animation" menu, "Color", then"Bar chart".
5 The "Draw" and "Aspect" tabs are used to define the object.
6 Select the "Bar chart" tab and click on the arrow of the drop down list in the"Measure" window.
7 Click on the button in the "Clusters" window, select your alias and your variable(giving the level) to be associated with the Bar chart, then validate. The Bar chart iscreated and defined.
8 Click the "Mode" menu, then "Execution". We are now in execution mode, and thebar chart shows the level of the tank.
Step Action
1 In the "File" menu, click "New". The window "New synoptic" will then be displayed.Give a name to your synoptic, then validate
2 In the "Draw" menu, click on text and write a character string.
3 Select the text then go to the "Animation" menu, "Text", then click "Measurement ofstates".
4 The "Draw" and "Aspect" tabs are used to define the object.
5 Select the "Display measurement of states" tab and click on the arrow of the dropdown list in the "Measure" window.
6 Click on the button in the "Clusters" window, select your alias and your variable(giving the number of cars) to be associated with the text, then validate. The text isdefined.
Vijeo Look 33
-
Start-up
Perform the same procedure four times for this example.
To create a counter showing the total number of painted cars, proceed as follows:
Step Action
1 In the "Draw" menu, click on text and write a character string.
2 Select the text then go to the "Animation" menu, "Text", then click "Measurement ofstates".
3 Select the "Display measurement of states" tab and write the formula giving the sumof the four counters: " = Var1 +Var2 +Var3 +Var4" (for example) then validate. Thecounter showing the total number of painted cars is created.
4 Click the "Mode" menu, then "Execution". We are now in execution mode. Thecounter shows the total number of painted cars.
34 VijeoLook
-
Start-up
Creating part of the "purification" synoptic
Description This demonstration project uses for the most part the "Status command", via the bitsand animation object "Color status groups". As for the "manufacturing demo", theinsert images tool is used to integrate the PLC photo.
Illustration of the example:
The tanks have been created by inserting an image, then superimposing an ellipse("Draw" menu).
The tanks are distinguishable by their contents and their color:� Tank 1: blue coloring,� Tank 2: yellow coloring,� Tank 3: red coloring.� Tank 4: the coloring color depends on the status of the valves V1, V2 and V3.
Tank 1:Tank 2:Tank 3:
Tank 4:
Propeller speed
ValueMin.
Max.
Administrator 1 Purification station 11/10/01 13:54:17
11/10/2001 13:58:31 Alarm on - not ack Device1.Default0111/10/2001 13:58:31 Alarm on - not ack Device1.Default01
Valve 1Valve 2Valve 3
Reservoir 1
Vijeo Look 35
-
Start-up
Creating an On/Off button
Creating an On/Off button for the valve:
In this example therefore, three buttons must be created altogether.
Step Action
1 Before launching Vijeo Look:� create an alias (give a name, and define the network type) in the OFS
configuration tool (see Reminder about editing aliases, p. 25), then validate,� launch Vijeo Look
2 In the "File" menu, click "New". The window "New synoptic" will then be displayed.Click on OK to access your synoptic.
3 In the "Draw" menu create a rectangle.
4 Select the created rectangle and go to the "Animation" menu, "Send", then"Animated command".
5 The "Draw" and "Aspect" tabs are used to define the object.
6 Select the "Command status" tab and click on the arrow of the drop down list fromthe "Status" window.
7 Click on the button in the "Cluster" window, select your alias and your bit typevariable (giving the valve status) to be associated with the "Command status",then validate.
8 Select the "Colors status" tab, set up the colors of the button according to its statusand click on the arrow of the list from the "Status" window.
9 Click on the button in the "Cluster" window, select your alias and your bit typevariable (giving the valve status) to be associated with the "Colors status", thenvalidate. The animated Command is created and defined.
10 Click the "Mode" menu, then "Execution". Once in execution mode, one click onthe button should change the status and the color.
36 VijeoLook
-
Start-up
The color of the coloring in "tank 4" and in "Reservoir 1" depends on the status ofthe valves "V1, V2 and V3".For example: if "V1" = 1, "V2" = 0 and "V3" = 0 then the color is blue.Summary of possible combinations:
Status of V1 Status of V2 Status of V3 Color
0 0 0 -
0 0 1 Red
0 1 0 Yellow
0 1 1 Orange
1 0 0 Blue
1 0 1 Pink
1 1 0 Green
1 1 1 Light blue
Vijeo Look 37
-
Start-up
Creating a"Groupedstatus"
Changing the coloring color of "Reservoir 1" and "Tank 4" according to the status ofthe valves (example whereby the coloring color appears in the drawing for "Tank 4"):
Step Action
1 In the "File" menu, click "New". The window "New synoptic" will then bedisplayed. Click on OK to gain access to your synoptic.
2 Using the "Draw" menu create an Ellipse.
3 Select the ellipse, then go to the "Animation" menu, "Color", then click "Statusgroups".The following window appears:
Reading the color palette:� read from left to right,� associate the two leftmost figures with those next to the color,� for example: pink = 01 & 01 = 0101.
4 The "Draw" and "Aspect" tabs are used to define the object.
5 Select the "Color status groups",
6 In the "Status of rank 0001" window, associate the variable of valve 1. Click onthe arrow from the drop down list.
7 Click on the button in the "Clusters" window, select your alias and variable(giving the valve status) to be associated with the "Status of rank xxxx", thenvalidate. Do the same for "Status of rank 0010" and "Status of rank 0100". The"Status groups" animation has been created and finalized.
Properties of the object
Draw Aspect Color status groups
Rank status 0001
Rank status 0010
Rank status 0100
Rank status 1000
V1%
V2%
V3%
Colors
Invalid status
38 VijeoLook
-
Start-up
8 Tick the boxes of all the possible combinations and assign the correspondingcolors to these by clicking on the color window.� If you wish to create pink, you must add blue and red. Which corresponds
to creating an "or" function between the status of V1, V2 and V3 for blueand red, i.e.:� status for the color blue: 0001
status for the color red: 0100The result is: 0001 + 0100 = 0101 for the color pink. This value is usedto set up the colors in the diagram below.
Using the table described above that shows the color according to the statusof V1, V2 and V3, it is possible to set up all combinations.
9 Click the "Mode" menu, then "Execution". Execution mode is now activated. Tocheck that it is operating correctly, test the combinations of the table describedabove.
Step Action
Vijeo Look 39
-
Start-up
Inserting an ActiveX and a Bean component
Example ofinserting anActiveX
Using an ActiveX (See Description of the main functions of the "Insert" menu, p. 22)you can, by a simple click, create a link in your project to an HTML page, an internetsite, etc.
Description of the procedure to follow:
Step Action
1 Launch Vijeo Look
2 In the "File" menu, click "New". The "New synoptic" window will then bedisplayed. Click OK to access your synoptic.
3 You are now in "Edit" mode. Pre-select the ActiveX controls in the Tools/Ergonomics/ActiveX Control menu.
4 Click on the "Insert" menu, then "ActiveX Control ...". The ActiveX controlspresent in this field are pre-selected.
5 Tick and select "Microsoft Web Browser", then validate.
6 Right-click on the ActiveX, then click on "Visualize script".
7 Type the following code (example of accessing the Schneider Automationsite):Private Sub Mimic_OpenWebBrowser1.Navigate2 ("http://www.schneider-automation.com")End Sub
8 Return to the Vijeo Look synoptic, maximize the ActiveX so as to view amaximum of information, and save your project.
9 Click the "Mode" menu, then "Execution".
10 You are now in "Execution" mode: Internet should open and launch thewww.Schneider-Automation.com site
Note: You can, for example, create your own browser on the internet using thetools offered in the ActiveX script. By right-clicking on the mouse, a list appears:click on "List Properties/Methods". All of these tools can be used to develop in VBAand create scripts for your applications.
40 VijeoLook
-
Start-up
Example ofinserting a Beancomponent
With Bean components (See Description of the main functions of the "Insert" menu,p. 22) objects can be used to display numerical values by creating a link betweenthe variable and the Bean component.
Description of the procedure for displaying a numerical value via an analog device:
Step Action
1 Launch Vijeo Look
2 In the "File" menu, click "New". The "New synoptic" window will then bedisplayed. Assign a name to your synoptic, then validate
3 You are now in "Edit" mode. Click on the "Insert" menu, then "BeanComponent".
4 Select "widgetsex.jar" then "com" then "schneiderautomation" then "widgets"and finally, click on "MeterEx.class".
5 Select the Bean component inserted, then click on "List of Properties" in the"Display" menu.
6 Click on "Variable Links", then on "input", and, finally, on the right-handdrop down menu.
7 Click on the button of the "Clusters" window: the aliases created in theconfiguration tool appear. Select your alias and choose the variable to beassociated with the Bean component.You can, for example, associate the "Speed" variable from the "Helix1"subdirectory of the alias "Waterplant".Save your configuration. In the "Mode" menu, click on "Execution".
8 You are now in "Execution" mode, and the display pointer indicates the valueof the variable.
Note: When a Java Bean is used or inserted, the Java Runtime environment isautomatically launched.
Vijeo Look 41
-
Start-up
Writing a variable
Example using asetpoint
Using the Send Setpoint command, it is possible to change the value of a variablewhile remaining in execution mode.
Description of the procedure to follow:
Step Action
1 Launch Vijeo Look.
2 In the "File" menu, click "New". The "New synoptic" window will then bedisplayed. Click OK to access your synoptic.
3 You are now in "Edit" mode. Click on the "Mode" menu, then on "Text".
4 Type a comment (only visible in "Edit" mode).
5 Select your text then go to the "Animation" menu, "Send", then "Setpoint".
6 Associate your variable in the space provided in the Measurement field byclicking on the drop down menu, then on the button in the "Clusters" window.Next, choose your alias and the variable associated with this alias.
7 Associate a comment with your variable (@ + text) and choose your sendmode (keyboard, etc.).
8 Click the "Mode" menu, then "Execution". You are now in execution mode, asimple click on the variable will enable you to change the value using thekeyboard or another send mode.
42 VijeoLook
-
CBAIndex
AActiveX, 22
Insertion, 40Alarm window, 23Alias
Creation, 27Edit, 25
BBean component, 22
Insertion, 41
CCreating
a "grouped status", 38a bar chart, 33a counter, 33an On/Off button, 36
DData server, 24
IInsert menu, 22Inserting
an image, 32
Vijeo Look
LLog server, 24Log window, 23
TTool Menu, 24trend curve, 22
VVijeo Look
General Overview, 7Installation, 10License, 14Tools, 20Uninstall, 13
WWriting a variable, 42
43
-
Index
44
VijeoLook
Vijeo LookTable of ContentsAbout the book
General overview of Vijeo LookInstalling the product Vijeo LookMain functions of Vijeo LookReminder about the OFS configuration toolStart-upIndex