VieVS User Workshop 7 – 9 September, 2010 Vienna VIE_INIT Tobias Nilsson.
VieVS User Workshop 14 – 16 September, 2011 Vienna VIE_SIM Jing SUN, Andrea PANY.
-
date post
21-Dec-2015 -
Category
Documents
-
view
216 -
download
2
Transcript of VieVS User Workshop 14 – 16 September, 2011 Vienna VIE_SIM Jing SUN, Andrea PANY.
![Page 1: VieVS User Workshop 14 – 16 September, 2011 Vienna VIE_SIM Jing SUN, Andrea PANY.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649d635503460f94a467cb/html5/thumbnails/1.jpg)
VieVS User Workshop
14 – 16 September, 2011
Vienna
VIE_SIM
Jing SUN, Andrea PANY
![Page 2: VieVS User Workshop 14 – 16 September, 2011 Vienna VIE_SIM Jing SUN, Andrea PANY.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649d635503460f94a467cb/html5/thumbnails/2.jpg)
2VieVS User Workshop 2011
Why simulations?
generate artificial delay observables – useful to test
new scheduling strategies
different station network geometries
antenna specifications
...
![Page 3: VieVS User Workshop 14 – 16 September, 2011 Vienna VIE_SIM Jing SUN, Andrea PANY.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649d635503460f94a467cb/html5/thumbnails/3.jpg)
VieVS User Workshop 2011 3
generate artificial delay observables – useful to test
new scheduling strategies
different station network geometries
antenna specifications
...
generate zero input NGS files – useful to test the impact of different models in the analysis
Why simulations?
![Page 4: VieVS User Workshop 14 – 16 September, 2011 Vienna VIE_SIM Jing SUN, Andrea PANY.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649d635503460f94a467cb/html5/thumbnails/4.jpg)
4VieVS User Workshop 2011
What is simulated?
o-c = (zwd2·mf(el2) + clk2) – (zwd1·mf(el1) + clk1) + wnbsl
![Page 5: VieVS User Workshop 14 – 16 September, 2011 Vienna VIE_SIM Jing SUN, Andrea PANY.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649d635503460f94a467cb/html5/thumbnails/5.jpg)
5VieVS User Workshop 2011
What is simulated?station 2 station 1
o-c = (zwd2·mf(el2) + clk2) – (zwd1·mf(el1) + clk1) + wnbsl
![Page 6: VieVS User Workshop 14 – 16 September, 2011 Vienna VIE_SIM Jing SUN, Andrea PANY.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649d635503460f94a467cb/html5/thumbnails/6.jpg)
6VieVS User Workshop 2011
What is simulated?
zwd - troposphere zenith wet delay
provided by a turbulence simulator
based on the approach by Nilsson et al. (2007)accounts for spatial and temporal correlations
station 2 station 1
o-c = (zwd2·mf(el2) + clk2) – (zwd1·mf(el1) + clk1) + wnbsl
![Page 7: VieVS User Workshop 14 – 16 September, 2011 Vienna VIE_SIM Jing SUN, Andrea PANY.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649d635503460f94a467cb/html5/thumbnails/7.jpg)
7VieVS User Workshop 2011
What is simulated?
mf(el) - mapping function (elevation)
station 2 station 1
zenith
mapping function
o-c = (zwd2·mf(el2) + clk2) – (zwd1·mf(el1) + clk1) + wnbsl
you should use thesame mf for the creationof the simulated files andfor the processing of thesimulated data – unlessyou want to study mf errors
![Page 8: VieVS User Workshop 14 – 16 September, 2011 Vienna VIE_SIM Jing SUN, Andrea PANY.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649d635503460f94a467cb/html5/thumbnails/8.jpg)
8VieVS User Workshop 2011
What is simulated?
clk - station clock
simulated as sum of a random walk andan integrated random walk process
according to Herring et al. 1990
station 2 station 1
o-c = (zwd2·mf(el2) + clk2) – (zwd1·mf(el1) + clk1) + wnbsl
![Page 9: VieVS User Workshop 14 – 16 September, 2011 Vienna VIE_SIM Jing SUN, Andrea PANY.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649d635503460f94a467cb/html5/thumbnails/9.jpg)
9VieVS User Workshop 2011
What is simulated?
wnbsl - white noise per baseline
station 2 station 1
o-c = (zwd2·mf(el2) + clk2) – (zwd1·mf(el1) + clk1) + wnbsl
![Page 10: VieVS User Workshop 14 – 16 September, 2011 Vienna VIE_SIM Jing SUN, Andrea PANY.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649d635503460f94a467cb/html5/thumbnails/10.jpg)
10VieVS User Workshop 2011
VIE_INIT
VIE_MOD
VIE_SIM
VieVS and VIE_SIM
![Page 11: VieVS User Workshop 14 – 16 September, 2011 Vienna VIE_SIM Jing SUN, Andrea PANY.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649d635503460f94a467cb/html5/thumbnails/11.jpg)
11VieVS User Workshop 2011
VIE_INIT
VIE_MOD
VIE_SIM
VieVS and VIE_SIM
artif
icia
l
NGS file
s
![Page 12: VieVS User Workshop 14 – 16 September, 2011 Vienna VIE_SIM Jing SUN, Andrea PANY.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649d635503460f94a467cb/html5/thumbnails/12.jpg)
12VieVS User Workshop 2011
VIE_INIT
VIE_MOD
VIE_SIM
VIE_INIT
VIE_MOD
VIE_LSM
VieVS and VIE_SIM
artif
icia
l
NGS file
s
![Page 13: VieVS User Workshop 14 – 16 September, 2011 Vienna VIE_SIM Jing SUN, Andrea PANY.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649d635503460f94a467cb/html5/thumbnails/13.jpg)
13VieVS User Workshop 2011
Data flow in VIE_SIM
vie_sim
scanantenna
simparamparamfile
INPUT
![Page 14: VieVS User Workshop 14 – 16 September, 2011 Vienna VIE_SIM Jing SUN, Andrea PANY.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649d635503460f94a467cb/html5/thumbnails/14.jpg)
14VieVS User Workshop 2011
Data flow in VIE_SIM
INPUT az, el and mjd are extracted and sorted by station
vie_sim
scanantenna
simparamparamfile
![Page 15: VieVS User Workshop 14 – 16 September, 2011 Vienna VIE_SIM Jing SUN, Andrea PANY.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649d635503460f94a467cb/html5/thumbnails/15.jpg)
15VieVS User Workshop 2011
Data flow in VIE_SIM
sim_swd
sim_clk
sim_wn
INPUT az, el and mjd are extracted and sorted by station
vie_sim
scanantenna
simparamparamfile
![Page 16: VieVS User Workshop 14 – 16 September, 2011 Vienna VIE_SIM Jing SUN, Andrea PANY.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649d635503460f94a467cb/html5/thumbnails/16.jpg)
16VieVS User Workshop 2011
Data flow in VIE_SIM
sim_swd
sim_clk
sim_wn
vie_sim
INPUT az, el and mjd are extracted and sorted by station
group delays are formed and stored scanwise
scanantenna
simparamparamfile
![Page 17: VieVS User Workshop 14 – 16 September, 2011 Vienna VIE_SIM Jing SUN, Andrea PANY.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649d635503460f94a467cb/html5/thumbnails/17.jpg)
17VieVS User Workshop 2011
Data flow in VIE_SIM
sim_swd
sim_clk
sim_wn
vievs2ngs
vie_sim
INPUT az, el and mjd are extracted and sorted by station
group delays are formed and stored scanwise
scanantenna
simparamparamfile
![Page 18: VieVS User Workshop 14 – 16 September, 2011 Vienna VIE_SIM Jing SUN, Andrea PANY.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649d635503460f94a467cb/html5/thumbnails/18.jpg)
18VieVS User Workshop 2011
Data flow in VIE_SIM
sim_swd
sim_clk
sim_wn
vievs2ngs
vie_sim
INPUT az, el and mjd are extracted and sorted by station
group delays are formed and stored scanwise OUTPUT
NGS-filesDATA/SIM
scanantenna
simparamparamfile
![Page 19: VieVS User Workshop 14 – 16 September, 2011 Vienna VIE_SIM Jing SUN, Andrea PANY.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649d635503460f94a467cb/html5/thumbnails/19.jpg)
19VieVS User Workshop 2011
The output of VIE_SIM
NGS-files
![Page 20: VieVS User Workshop 14 – 16 September, 2011 Vienna VIE_SIM Jing SUN, Andrea PANY.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649d635503460f94a467cb/html5/thumbnails/20.jpg)
20VieVS User Workshop 2011
The output of VIE_SIM
NGS-files
we simulate the (o-c) vector and write the (o-c) + c to the observed value in the NGS-files
![Page 21: VieVS User Workshop 14 – 16 September, 2011 Vienna VIE_SIM Jing SUN, Andrea PANY.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649d635503460f94a467cb/html5/thumbnails/21.jpg)
21VieVS User Workshop 2011
The output of VIE_SIM
NGS-files
we simulate the (o-c) vector and write the (o-c) + c to the observed value in the NGS-files
ionosphere correction and cable cal need to be taken into account
![Page 22: VieVS User Workshop 14 – 16 September, 2011 Vienna VIE_SIM Jing SUN, Andrea PANY.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649d635503460f94a467cb/html5/thumbnails/22.jpg)
22VieVS User Workshop 2011
The output of VIE_SIM
NGS-files
we simulate the (o-c) vector and write the (o-c) + c to the observed value in the NGS-files
ionosphere correction and cable cal need to be taken into account
interface for exchange of simulated data
![Page 23: VieVS User Workshop 14 – 16 September, 2011 Vienna VIE_SIM Jing SUN, Andrea PANY.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649d635503460f94a467cb/html5/thumbnails/23.jpg)
23VieVS User Workshop 2011
Before running VIE_SIM
create an empty OPT directory (e.g. "SIM") and use this for the simulations (if OPT files exist)
![Page 24: VieVS User Workshop 14 – 16 September, 2011 Vienna VIE_SIM Jing SUN, Andrea PANY.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649d635503460f94a467cb/html5/thumbnails/24.jpg)
24VieVS User Workshop 2011
Before running VIE_SIMrename the OPT files for the sessions for which you want to simulate (if OPT files exist)Do not use any outlier files!
![Page 25: VieVS User Workshop 14 – 16 September, 2011 Vienna VIE_SIM Jing SUN, Andrea PANY.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649d635503460f94a467cb/html5/thumbnails/25.jpg)
25VieVS User Workshop 2011
Before running VIE_SIMrename the OPT files for the sessions for which you want to simulate (if OPT files exist)Do not use any outlier files!make sure to set the quality code limit in the 2nd GUI to >9 (it is important that all observations are used for the simulation)
![Page 26: VieVS User Workshop 14 – 16 September, 2011 Vienna VIE_SIM Jing SUN, Andrea PANY.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649d635503460f94a467cb/html5/thumbnails/26.jpg)
26VieVS User Workshop 2011
Before running VIE_SIMrename the OPT files for the sessions for which you want to simulate (if OPT files exist)Do not use any outlier files!make sure to set the quality code limit in the 2nd GUI to >9 (it is important that all observations are used for the simulation)After the simulation you can process the simulated data with any options you like!
![Page 27: VieVS User Workshop 14 – 16 September, 2011 Vienna VIE_SIM Jing SUN, Andrea PANY.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649d635503460f94a467cb/html5/thumbnails/27.jpg)
27VieVS User Workshop 2011
start VieVS as usual
How to start the simulator
![Page 28: VieVS User Workshop 14 – 16 September, 2011 Vienna VIE_SIM Jing SUN, Andrea PANY.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649d635503460f94a467cb/html5/thumbnails/28.jpg)
28VieVS User Workshop 2011
How to start the simulator
start VieVS as usual
in the first GUI choose the sessions for which you want to simulate
![Page 29: VieVS User Workshop 14 – 16 September, 2011 Vienna VIE_SIM Jing SUN, Andrea PANY.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649d635503460f94a467cb/html5/thumbnails/29.jpg)
29VieVS User Workshop 2011
start VieVS as usual
in the first GUI choose the sessions for which you want to simulate
then choose to run VIE_SIM
How to start the simulator
![Page 30: VieVS User Workshop 14 – 16 September, 2011 Vienna VIE_SIM Jing SUN, Andrea PANY.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649d635503460f94a467cb/html5/thumbnails/30.jpg)
30VieVS User Workshop 2011
do not use outlier files!
if OPT files exist, create an empty OPT directory (e.g. “SIM”) and use this for the simulations before starting the simulator.
How to start the simulator
![Page 31: VieVS User Workshop 14 – 16 September, 2011 Vienna VIE_SIM Jing SUN, Andrea PANY.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649d635503460f94a467cb/html5/thumbnails/31.jpg)
31VieVS User Workshop 2011
set the quality code limit to a number > 9
How to start the simulator
![Page 32: VieVS User Workshop 14 – 16 September, 2011 Vienna VIE_SIM Jing SUN, Andrea PANY.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649d635503460f94a467cb/html5/thumbnails/32.jpg)
32VieVS User Workshop 2011
The simulator GUI
choose the parameters to be simulated
![Page 33: VieVS User Workshop 14 – 16 September, 2011 Vienna VIE_SIM Jing SUN, Andrea PANY.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649d635503460f94a467cb/html5/thumbnails/33.jpg)
33VieVS User Workshop 2011
The simulator GUI
enter the number of days and a starting point for the running number of the NGS files
![Page 34: VieVS User Workshop 14 – 16 September, 2011 Vienna VIE_SIM Jing SUN, Andrea PANY.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649d635503460f94a467cb/html5/thumbnails/34.jpg)
34VieVS User Workshop 2011
The simulator GUI
choose a file containing the simulation parameters (can be station specific) …
![Page 35: VieVS User Workshop 14 – 16 September, 2011 Vienna VIE_SIM Jing SUN, Andrea PANY.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649d635503460f94a467cb/html5/thumbnails/35.jpg)
35VieVS User Workshop 2011
Simulation parameter file
station names (8 characters)
![Page 36: VieVS User Workshop 14 – 16 September, 2011 Vienna VIE_SIM Jing SUN, Andrea PANY.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649d635503460f94a467cb/html5/thumbnails/36.jpg)
36VieVS User Workshop 2011
Simulation parameter file
turbulence parametersCn refractive index structure constant [10 -7m -1/3]H effective height of wet troposphere [m]vn, ve components of the wind vector [m/s]
![Page 37: VieVS User Workshop 14 – 16 September, 2011 Vienna VIE_SIM Jing SUN, Andrea PANY.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649d635503460f94a467cb/html5/thumbnails/37.jpg)
37VieVS User Workshop 2011
Simulation parameter file
a priori zenith wet delay [mm]
![Page 38: VieVS User Workshop 14 – 16 September, 2011 Vienna VIE_SIM Jing SUN, Andrea PANY.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649d635503460f94a467cb/html5/thumbnails/38.jpg)
38VieVS User Workshop 2011
Simulation parameter file
correlation interval [h] andstepwidth [m] for the numericalintegration
![Page 39: VieVS User Workshop 14 – 16 September, 2011 Vienna VIE_SIM Jing SUN, Andrea PANY.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649d635503460f94a467cb/html5/thumbnails/39.jpg)
39VieVS User Workshop 2011
Simulation parameter file
clock Allan Standard Deviation (ASD)
![Page 40: VieVS User Workshop 14 – 16 September, 2011 Vienna VIE_SIM Jing SUN, Andrea PANY.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649d635503460f94a467cb/html5/thumbnails/40.jpg)
40VieVS User Workshop 2011
Simulation parameter file
white noise [ps]
![Page 41: VieVS User Workshop 14 – 16 September, 2011 Vienna VIE_SIM Jing SUN, Andrea PANY.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649d635503460f94a467cb/html5/thumbnails/41.jpg)
41VieVS User Workshop 2011
The simulator GUI
… or directly enter the values – these will then be applied to all stations
![Page 42: VieVS User Workshop 14 – 16 September, 2011 Vienna VIE_SIM Jing SUN, Andrea PANY.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649d635503460f94a467cb/html5/thumbnails/42.jpg)
42VieVS User Workshop 2011
The simulator GUI
units! [1e-7m-1/3]
![Page 43: VieVS User Workshop 14 – 16 September, 2011 Vienna VIE_SIM Jing SUN, Andrea PANY.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649d635503460f94a467cb/html5/thumbnails/43.jpg)
43VieVS User Workshop 2011
The simulator GUI
additional option: set reference clock to zero
![Page 44: VieVS User Workshop 14 – 16 September, 2011 Vienna VIE_SIM Jing SUN, Andrea PANY.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649d635503460f94a467cb/html5/thumbnails/44.jpg)
44VieVS User Workshop 2011
simulated NGS files are stored to VieVS / DATA / SIM / year
Where the data are stored
![Page 45: VieVS User Workshop 14 – 16 September, 2011 Vienna VIE_SIM Jing SUN, Andrea PANY.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649d635503460f94a467cb/html5/thumbnails/45.jpg)
VieVS User Workshop 2011
simulated NGS files are stored to VieVS / DATA / SIM / year
in DATA / LEVEL4 / your_dir you find
Where the data are stored
![Page 46: VieVS User Workshop 14 – 16 September, 2011 Vienna VIE_SIM Jing SUN, Andrea PANY.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649d635503460f94a467cb/html5/thumbnails/46.jpg)
VieVS User Workshop 2011
simulated NGS files are stored to VieVS / DATA / SIM / year
in DATA / LEVEL4 / your_dir you find
Where the data are stored
a MATLAB structurearray that containsaz, el, and MJDsorted by station
stored only oncefor each session
![Page 47: VieVS User Workshop 14 – 16 September, 2011 Vienna VIE_SIM Jing SUN, Andrea PANY.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649d635503460f94a467cb/html5/thumbnails/47.jpg)
VieVS User Workshop 2011
simulated NGS files are stored to VieVS / DATA / SIM / year
in DATA / LEVEL4 / your_dir you find
Where the data are stored
a MATLAB structurearray that containsthe mapping functionsorted by station
stored only oncefor each session
![Page 48: VieVS User Workshop 14 – 16 September, 2011 Vienna VIE_SIM Jing SUN, Andrea PANY.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649d635503460f94a467cb/html5/thumbnails/48.jpg)
VieVS User Workshop 2011
simulated NGS files are stored to VieVS / DATA / SIM / year
in DATA / LEVEL4 / your_dir you find
Where the data are stored
a MATLAB structurearray that containsthe simulated correlationmatrices for each station
stored for eachsimulation
![Page 49: VieVS User Workshop 14 – 16 September, 2011 Vienna VIE_SIM Jing SUN, Andrea PANY.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649d635503460f94a467cb/html5/thumbnails/49.jpg)
VieVS User Workshop 2011
simulated NGS files are stored to VieVS / DATA / SIM / year
in DATA / LEVEL4 / your_dir you find
Where the data are stored
a MATLAB structurearray that containsthe simulated values ofswd, clk, and wnfor each station
stored for eachsimulation
![Page 50: VieVS User Workshop 14 – 16 September, 2011 Vienna VIE_SIM Jing SUN, Andrea PANY.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649d635503460f94a467cb/html5/thumbnails/50.jpg)
start VieVS as usual
How to process simulated data
VieVS User Workshop 2011
![Page 51: VieVS User Workshop 14 – 16 September, 2011 Vienna VIE_SIM Jing SUN, Andrea PANY.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649d635503460f94a467cb/html5/thumbnails/51.jpg)
VieVS User Workshop 2011
choose to use simulated data
How to process simulated data
![Page 52: VieVS User Workshop 14 – 16 September, 2011 Vienna VIE_SIM Jing SUN, Andrea PANY.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649d635503460f94a467cb/html5/thumbnails/52.jpg)
VieVS User Workshop 2011
select the simulated NGS file(s)
then proceed as
with real data
How to process simulated data
![Page 53: VieVS User Workshop 14 – 16 September, 2011 Vienna VIE_SIM Jing SUN, Andrea PANY.](https://reader036.fdocuments.in/reader036/viewer/2022062516/56649d635503460f94a467cb/html5/thumbnails/53.jpg)
53VieVS User Workshop 2011
problems? questions? mail to [email protected]
Jing Sun would like to thank the FWF for funding project SCHED2010 ((P21049-N14).
Andrea Pany is a recipient of a DOC-fFORTE fellowship of the Austrian Academy of Sciences at the Institute
of Geodesy and Geophysics, Vienna University of Technology.