VIDAS BLUE VIDAS BLUE PRESENTATION VIDAS BLUE VIDAS BLUE: New Vidas and mini Vidas look.

download VIDAS BLUE VIDAS BLUE PRESENTATION VIDAS BLUE VIDAS BLUE: New Vidas and mini Vidas look.

of 35

  • date post

    29-Mar-2015
  • Category

    Documents

  • view

    232
  • download

    2

Embed Size (px)

Transcript of VIDAS BLUE VIDAS BLUE PRESENTATION VIDAS BLUE VIDAS BLUE: New Vidas and mini Vidas look.

  • Slide 1

Slide 2 VIDAS BLUE VIDAS BLUE PRESENTATION Slide 3 VIDAS BLUE VIDAS BLUE: New Vidas and mini Vidas look Slide 4 VIDAS BLUE The main changes Slide 5 VIDAS BLUE Slide 6 Strip preparation tray Blue tray covers Slide 7 VIDAS BLUE Removing strip preparation tray Slide 8 Mini VIDAS BLUE Slide 9 New screen / keyboard Holder New printer paper holder Slide 10 Internal changes VIDAS BLUE Slide 11 On mini VIDAS: Addition of a long screw to fix the right trim Slide 12 VIDAS BLUE On mini VIDAS: Screen/keyboard holder 3 fixing points: Slide 13 VIDAS BLUE New Power Supply Assembly: - - Only 4 external points of fixation (4 screw) - - Central chimney (V30) - - No railing(bar) Slide 14 VIDAS BLUE New Power Supply Assembly: - Only 1 Power Supply Board (V12/V30) - 1 air fan - Self switching Power Supply (110/220V) Slide 15 VIDAS BLUE New Power Supply Board: - -Dedicated mini Vidas and Vidas connectors. VIDAS Mini VIDAS Be carefull Respect the correct connector! Slide 16 VIDAS BLUE New Power Supply Board: - -Air Fan Fixed by 4 plastic retainersFixed by 4 plastic retainers Spare partSpare part If Air Fan out of service:If Air Fan out of service: Software T error will be Software T error will begenerated Automatic Power Supply Automatic Power Supply cut off Slide 17 VIDAS BLUE New tray ball bearings: Excentric ball bearing replaced by a normal one fixed on a spring mechanism. No more lateral play to adjust Slide 18 VIDAS BLUE Tray motor assembly: Addition of a pretensionning spring CAUTION! Lock the motor Assy when it is in the good position Slide 19 VIDAS BLUE Tower screw: Addition of a spacer To reduce the tower misalignments Slide 20 VIDAS BLUE Incubator door: - New door plunger ball nut - Addition of a safety latch Slide 21 VIDAS BLUE New electronic boards: Scanner Board Incubator Boards Slide 22 VIDAS BLUE New Scanner Board: Flash ROM U5 ( V2.51) (replace the EEPROM) DIP Switch SW3 (replace JP7/JP8/JP9) Power Supply LEDs (+5V/+10V/+12V/- 12V) New Power Supply 3.3V LED Sensors LEDs Scanner cable breakdown detection LEDs Communication LEDs Mini Vidas Blue Backlight Power Supply connector J15: Scanner Cable new Connector for failure detection (replace coax. cables ) Slide 23 VIDAS BLUE New Scanner Board: 100 % compatible with the old boards100 % compatible with the old boards One Flash ROM V 2.51 instead of 3 EPROM V2.41One Flash ROM V 2.51 instead of 3 EPROM V2.41 SW3 replaces Jumpers JP7 to JP9SW3 replaces Jumpers JP7 to JP9 New power supply 3,3VNew power supply 3,3V New connector (J18) dedicated to the mini Vidas screen backlight power supply.New connector (J18) dedicated to the mini Vidas screen backlight power supply. New connector (J15) for scanner failure detection ( replaces coax cables)New connector (J15) for scanner failure detection ( replaces coax cables) REF. SCANNER BOARDS : VD8201-1 Slide 24 VIDAS BLUE Slide 25 Slide 26 New Incubator Board: Double support Flash ROM U5 or EPROM V 3.10 DIP switch SW2 (replace adress/ reset jumpers) Power Supply LEDs Heaters LEDs Serial communication with scanner board LEDs Sensor LEDs Slide 27 VIDAS BLUE New Incubator Board: Available with EPROM 3.10 or Flash ROM Available with EPROM 3.10 or Flash ROM (same version) (same version) Dip Switch SW2 replace all Adress and Reset jumpers ( silkscreen directly on the board). Dip Switch SW2 replace all Adress and Reset jumpers ( silkscreen directly on the board). LEDS for Power Supply, communication, LEDS for Power Supply, communication, sensors and heaters. sensors and heaters. Fuses (SMD) F1 to F4 Fuses (SMD) F1 to F4 REF. INCUB.Board : VD8202-2 100% compatible with the old boards 100% compatible with the old boards Slide 28 VIDAS BLUE Slide 29 Slide 30 SCANNER SCANNER: new parts New mini VIDAS/ VIDAS scanner cables New mini VIDAS/ VIDAS scanner cables New scanner cables with failure detection (replace coaxial cables) The blue flat cable is still the same Slide 31 VIDAS BLUE SCANNER SCANNER: new parts New Scanner PRE-AMP board New Scanner PRE-AMP board J1 connector unchanged, use with J1 connector unchanged, use with both old scanner cble kits and new Scanner cables. New J2 connector, is only used with New J2 connector, is only used with new scanner cables and new scanner Board. (Allows scanner cable failure detection) Slide 32 VIDAS BLUE : reminder The scanner cable failure detection system is available only with a new Scanner Cable, new Scanner Board, with a new Scanner Cable, new Scanner Board, and new Scanner Head. The LEDs (DS9 to DS12 from the new scanner board) are on When a cable is broken. ( off = cables OK) If a scanner cable failure is detected, a blocking error 161 will be generated. The new Scanner head is compatible with the old Scanner head But dont forget to replace the new scanner cable by an old scanner cable kit in order to be compatible with the old scanner board Slide 33 VIDAS BLUE Changes impact Decontamination: a new procedure has been defined to take Decontamination: a new procedure has been defined to take Into account the Strip preparation tray . Error 161: If err. 161, check the integrity of the scanner cables. ( LEDs off on scanner board = good) Error 161: If err. 161, check the integrity of the scanner cables. ( LEDs off on scanner board = good) PM : Scanner cable replacement every 2 years PM : Scanner cable replacement every 2 years Non Applicable Non Applicable PM : tray lateral play not necessary to set PM : tray lateral play not necessary to set PM : Power Supply not necessary to open it during a PM (If dead, replace the complete block.) Slide 34 VIDAS BLUE Compatibility table (*) Scanner Head Blue : put an old scanner cable kit (**) Scanner Cable Blue: only used with a new Scanner Head and new Scanner Board. Slide 35 VIDAS BLUE You will receive a specific Mandatory Action Required (MAR) from GCS soon. from GCS soon. Feel free to contact us for many information : E-mail : gcsimmunomarcy@eu.biomerieux.com gcsimmunomarcy@eu.biomerieux.com More details will be added in this MAR.