Vickers Flange Valves Flange Mounted Pressure Controls · 2013-07-09 · 2 Flange Mounted Valves...

64
627 Rev. 6/95 Relief, Unloading & Check Valves - 06, 08, 10 & 12 Size Flange Mounted Pressure Controls Vickers ® Flange Valves

Transcript of Vickers Flange Valves Flange Mounted Pressure Controls · 2013-07-09 · 2 Flange Mounted Valves...

Page 1: Vickers Flange Valves Flange Mounted Pressure Controls · 2013-07-09 · 2 Flange Mounted Valves Continued on next page Model/Size: Relief Valves Function Max. Pressure Max. Flow

627Rev. 6/95

Relief, Unloading & Check Valves - 06, 08, 10 & 12 Size

Flange Mounted Pressure Controls

Vickers®

Flange Valves

Page 2: Vickers Flange Valves Flange Mounted Pressure Controls · 2013-07-09 · 2 Flange Mounted Valves Continued on next page Model/Size: Relief Valves Function Max. Pressure Max. Flow

2

Flange Mounted ValvesContinued on next page

Model/Size:Relief Valves

Function Max.Pressure

Max. Flow Pressure Drop Vented ∆P to T at Max. Flow

Page

CPF1S-06SAE 3/4”

100 l/min (26 USgpm)

6

11

CPF1S-08SAE 1” 275 bar

(4000 i)

300 l/min (80 USgpm)

12

CPF1S-10SAE 1 1/4” Relief, single pressure

(4000 psi)–

13

CPF1S-12SAE 1 1/2” 600 l/min

(160 USgpm)

14

CPF1V-12 (code 62)SAE 1 1/2”

350 bar(5000 psi)

(160 USgpm)

CPF2S-06SAE 3/4” 100 l/min

(26 USgpm)

3,5 bar (51 psi)@ 100 l/min

(26,4 USgpm)

15

20

CPF2S-08SAE 1”

275 bar

300 l/min (80 USgpm)

4 bar (58 psi)@ 300 l/min (80 USgpm)

21

CPF2S-10SAE 1 1/4” Relief, single pressure with vent

275 bar (4000 psi) Internal Drain External Drain

7 bar (102 psi) 4,9 bar (71 psi)@ 600 l/min @ 600 l/min (160 USgpm) (160 USgpm)

22

CPF2S-12SAE 1 1/2”

600 l/min (160 USgpm) Internal Drain External Drain

7 5 b r (109 psi) 2 5 b r (36 psi)

23

CPF2V-12 (code 62)SAE 1 1/2”

350 bar(5000 psi)

7,5 bar (109 psi) 2,5 bar (36 psi)@ 600 l/min @ 600 l/min (160 USgpm) (160 USgpm)

CPF3S-06SAE 3/4”

100 l/min (26 USgpm)

3,5 bar (51 psi)@ 100 l/min

(26,4 USgpm)

24

29

CPF3S-08SAE 1”

275 bar

300 l/min (80 USgpm)

4 bar (58 psi)@ 300 l/min (80 USgpm)

30

CPF3S-10SAE 1 1/4” Bi-pressure relief with max. press. override

275 bar (4000 psi) Internal Drain External Drain

7 bar (102 psi) 4,9 bar (71 psi)@ 600 l/min @ 600 l/min (160 USgpm) (160 USgpm)

31

CPF3S-12SAE 1 1/2”

600 l/min (160 USgpm) Internal Drain External Drain

7 5 b r (109 psi) 2 5 b r (36 psi)

32

CPF3V-12 (code 62)SAE 1 1/2”

350 bar(5000 psi)

7,5 bar (109 psi) 2,5 bar (36 psi)@ 600 l/min @ 600 l/min (160 USgpm) (160 USgpm)

CPF4S-06SAE 3/4”

100 l/min (26 USgpm)

3,5 bar (51 psi)@ 100 l/min

(26,4 USgpm)

29

CPF4S-08SAE 1”

275 bar

300 l/min (80 USgpm)

4 bar (58 psi)@ 300 l/min (80 USgpm)

30

CPF4S-10SAE 1 1/4” Tri-pressure relief with max. press. override

275 bar (4000 psi) Internal Drain External Drain

7 bar (102 psi) 4,9 bar (71 psi)@ 600 l/min @ 600 l/min (160 USgpm) (160 USgpm)

31

CPF4S-12SAE 1 1/2”

600 l/min (160 USgpm) Internal Drain External Drain

7 5 b r (109 psi) 2 5 b r (36 psi)

32

CPF4V-12 (code 62)SAE 1 1/2”

350 bar(5000 psi)

7,5 bar (109 psi) 2,5 bar (36 psi)@ 600 l/min @ 600 l/min (160 USgpm) (160 USgpm)

Page 3: Vickers Flange Valves Flange Mounted Pressure Controls · 2013-07-09 · 2 Flange Mounted Valves Continued on next page Model/Size: Relief Valves Function Max. Pressure Max. Flow

3

Continued on next page

Model/Size:UnloadingValves

Function Max.Pressure

Max. Flow ∆P P to T in Unloaded Position Page

UPF1S-06SAE 3/4”

Unloading without check

100 l/min (26 US )

Internal Drain External Drain3,5 bar (51 psi) 2,5 bar (36 psi)@ 100 l/min @ 100 l/min

33

38

UPF1S-C*-06SAE 3/4”

Unloading with check (26 USgpm)@ 100 l/min @ 100 l/min (26,4 USgpm) (26,4 USgpm) 39

UPF1S-08SAE 1”

Unloading without check

300 l/min 3,5 bar (51 psi)@ 100 l/min

40

UPF1S-C*-08SAE 1”

Unloading with check 275 bar (4000 psi)

300 l/min (80 USgpm)

@ 100 l/min (26,4 USgpm) 41

UPF1S-10SAE 1 1/4”

Unloading without check Internal Drain External Drain7,5 bar (109 psi) 4,9 bar (71 psi)

42

UPF1S-C*-10SAE 1 1/4”

Unloading with check7,5 bar (109 si) 4,9 bar (71 si)@ 600 l/min @ 600 l/min (160 USgpm) (160 USgpm)

43

UPF1S-12SAE 1 1/2”

Unloading without check600 l/min

(160 USgpm)

44

UPF1V-12 (code 62)SAE 1 1/2”

Unloading without check 350 bar(5000 psi)

(160 USgpm) Internal Drain External Drain7,5 bar (109 psi) 3 bar (44 psi)@ 600 l/min @ 600 l/min (160 USgpm) (160 USgpm)

UPF1S-C*-12SAE 1 1/2”

Unloading with check(160 USgpm) (160 USgpm)

45

UPF2S-06SAE 3/4”

Unloading with vent without check

100 l/min (26 US )

Internal Drain External Drain3,5 bar (51 psi) 2,5 bar (36 psi)@ 100 l/min @ 100 l/min

46

51

UPF2S-C*-06SAE 3/4”

Unloading with vent and check 275 bar (4000 psi)

(26 USgpm)@ 100 l/min @ 100 l/min (26,4 USgpm) (26,4 USgpm) 52

UPF2S-08SAE 1”

Unloading with vent without check

300 l/min 3,5 bar (51 psi)@ 100 l/min

53

UPF2S-C*-08SAE 1”

Unloading with vent and check300 l/min

(80 USgpm)@ 100 l/min

(26,4 USgpm) 54

UPF2S-10SAE 1 1/4”

Unloading with vent without check Internal Drain External Drain7,5 bar (109 psi) 4,9 bar (71 psi)@ 600 l/ i @ 600 l/ i

55

UPF2S-C*-10SAE 1 1/4”

Unloading with vent and check 275 bar (4000 psi)

,5 b ( 09 s ) ,9 b ( s )@ 600 l/min @ 600 l/min (160 USgpm) (160 USgpm) 56

UPF2S-12SAE 1 1/2”

Unloading with vent without check

(4000 si)

600 l/min (160 USgpm)

57

UPF2V-12 (code 62)SAE 1 1/2”

Unloading with vent without check 350 bar(5000 psi)

(160 USgpm) Internal Drain External Drain7,5 bar (109 psi) 3 bar (44 psi)@ 600 l/min @ 600 l/min (160 USgpm) (160 USgpm)

UPF2S-C*-12SAE 1 1/2”

Unloading with vent and check 275 bar (4000 psi)

(160 USgpm) (160 USgpm)58

Page 4: Vickers Flange Valves Flange Mounted Pressure Controls · 2013-07-09 · 2 Flange Mounted Valves Continued on next page Model/Size: Relief Valves Function Max. Pressure Max. Flow

4

Model/Size:Check Valve

Function Max.Pressure

Max. Flow Pressure Drop Page

DCPFS-08SAE 1”

275 bar

114 l/min (30 USgpm)

13 bar (187 psi) @114 l/min (30 USgpm) - 3,4 bar (50 psi)cracking press. 9,4 bar (137 psi) @114 l/min(30 USgpm) - 0,3 bar (5 psi)cracking press.

59

62

DCPFS-10SAE 1 1/4”

Right Angle Check valve275 bar

(4000 psi) 227 l/min (60 USgpm)

4,1 bar (60 psi) @227 l/min (60 USgpm) - 0,3 (5 psi) crackingpress.

62

DCPFS-12SAE 1 1/2”

378 l/min (100 USgpm)

8,6 bar (125 psi) @378 l/min (100 USgpm) - 0,3 (5 psi) crackingpress.

62

DICPFS-06SAE .75”

350 bar

120 l/min (32 USgpm)

1,4 bar (20 psi) @120 l/min (32 USgpm) - 0,3 bar (5 psi)cracking press. 2,4 bar (35 psi) @120 l/min(32 USgpm) - 1,7 bar (25 psi)cracking press.

60

62

DICPFS-08SAE 1”

In line Check v lve

350 bar (5000 psi) 300 l/min

(80 USgpm)3,4 bar (49 psi) @300 l/min (80 USgpm) - 0,3 bar (5 psi)cracking press. 3,4 bar (49 psi) @300 l/min(80 USgpm) - 1,7 bar (25 psi)cracking press.

62

DICPFS-10SAE 1 1/4”

In-line Check valve280 bar

(4000 psi)600 l/min

(160 USgpm)8,3 bar (120 psi) @600 l/min (160 USgpm) - 0,3 bar (5 psi)cracking press. 8,3 bar (120 psi) @600 l/min(160 USgpm) - 1,7 bar (25 psi)cracking press.

62

DICPFS-12SAE 1 1/2”

207 bar (3000 psi)

750 l/min (200 USgpm)

4,1 bar (60 psi) @750 l/min (200 USgpm) - 0,3 (5 psi)cracking press.5,9 bar (85 psi) @750 l/min(200 USgpm) - 1,7 bar (25 psi) cracking press.

62

Page 5: Vickers Flange Valves Flange Mounted Pressure Controls · 2013-07-09 · 2 Flange Mounted Valves Continued on next page Model/Size: Relief Valves Function Max. Pressure Max. Flow

5

Introduction

������������� �������������

� Direct mounting to pump flangereduces potential leak points forsuperior leak resistance.

� Reduced installed costs andspace requirements.

� Excellent repeatability and stableperformance from cartridgedesign main stage parts.

� High response due to small trappedvolume.

� Easier installation and servicing ofcomponents.

� Pilot design minimizes responsetime and cracking flow which allowsfor high pressure stability thusincreasing system productivity.

� Fast opening and closing action andstable performance from cartridge design.

� Minimum unloaded pressure dropdue to short piping runs.

� Viton seals provide multi-fluidcapability without the need tochange seals.

Sizes

06 – 3/4” flange08 – 1” flange10 – 1 1/4” flange12 – 1 1/2” flange

General Description

Relief Valves

Vickers space saving CPF relief valvesimprove machine reliability and uptime bylimiting the pressure in a hydraulic circuit tothe desired maximum, thereby protectingthe hydraulic pump and system frompressure peaks. The CPF relief valves aredesigned to mount on a wide range ofSAE pump outlet port flanges to eliminateintervalve piping and fittings.

Direct pump flange mounting of thevalves reduces installation costs andprovides a highly leak–resistant,compact pump control package.

CPF relief valves are of two–stage designwith a fast–acting poppet type main stagefor simple, long-lasting and effectiveoperation. The pilot stage features asensitive adjustment mechanism whichallows setting of the pressure in fineincrements over a wide range – up to themaximum rating of the valve.

������������������ ��������������

� � ���������������������� ����� �����

� �� ������������� �����������������

������ ����������� �������������

�������������� ��������������������

��������������� !��� �������

������"�������������� ��� � � ������

������������#���� ������ ���� ����

�������� �������������������� ����

���� ������������ ������������

� ���������$������

These CPF relief valves have excellentdynamic and steady state operatingcharacteristics including stability, fastresponse and low pressure override.The many available control optionsmake it possible to choose the optimumvalve model for industrial and mobileapplications. Additionally, CPF valvesuse many of the same parts of otherVickers products to insure provendurability. For over 70 years, the Vickersname has been synonymous with long,trouble–free service.

Unloading Valves

Unloading valves are used inaccumulator charging circuits where apressure regulator is required toautomatically unload the pump. This isdone by diverting the pump delivery tothe reservoir at low pressure when thedesired accumulator pressure isreached. Also, the UPF unloading valvecan be used to unload the low pressureside of a double pump.

The UPF unloading valves are designedto mount directly on SAE pump outlet portflanges to eliminate intervalve piping andfittings. Direct pump flange mounting ofthe valves reduces installation costs andprovides a highly leak resistant, compactpump control package.

UPF unloading valves are of two-stagedesign with a fast acting poppet type mainstage for simple, long-lasting, and effectiveoperation. The pilot stage features asensitive adjustment mechanism whichallows setting of the pressure in fineincrements over a wide range – up to themaximum rating of the valve.

The pressure setting adjustment choicesavailable for the UPF unloading valves arethe standard screw-type adjuster withlocknut or optional adjusters with or withoutkeylock. Gage connections for pump andsystem pressures are available on allmodels. Additional optional features includevarious pressure setting ranges and manysolenoid valve options on valves soequipped.

Unloading valves may be ordered withor without the integral check valve.

Check Valves

DCPF/DICPF flange mounted rightangle and in-line check valves areruggedly designed for superior shockresistance, reliability and long life.

The check valves may be mounteddirectly on an SAE pump outlet portflange or may be stacked with a CPFrelief valve to provide a pump unloadingfunction. The DCPF/DICPF checkvalves are not intended for use as anunloading check.

The right angle and in-line check valvesare offered in sizes matching the CPFrelief valves.

Page 6: Vickers Flange Valves Flange Mounted Pressure Controls · 2013-07-09 · 2 Flange Mounted Valves Continued on next page Model/Size: Relief Valves Function Max. Pressure Max. Flow

6

CPF1*-06/08/10/12-**-20Relief Valve Without Venting

Flange Sizes� 06 - 3/4 inch flange� 08 - 1 inch flange� 10 - 11/4 inch flange� 12 - 11/2 inch flange

��������

��Direct mounting to pump flangereduces potential leak points forsuperior leak resistance.

� Reduced installed costs andspace requirements.

� Excellent repeatability and stableperformance from cartridgedesign mainstage parts.

� Easier installation and servicingof components (stackable design).

� Pilot design minimizes responsetime and cracking flow whichallows for high pressure stabilitythus increasing system productivity.

������� �������� ��������

Maximum flow 100 l/min (26 USgpm) 300 l/min (80 USgpm) 600 l/min (160 USgpm) 600 l/min (160 USgpm)Maximum pressure: P port 275 bar (4000 psi) 275 bar (4000 psi) 275 bar (4000 psi) 275 bar (4000 psi)* T port 207 bar (3000 psi) 207 bar (3000 psi) 207 bar (3000 psi) 207 bar (3000 psi)

����������������

* The CPF1V-12 (code 62 flange) has a P port max. pressure rating of 350 bar (5000 psi).

������� ����!���

10/12 Sizes: Rate of pressure rise with2,5 liters (.7 USgpm) of oil undercompression = 2600 bar (37500 psi)/second. Maximum overshoot < 10%.

06 Size: Rate of pressure rise with 2,5 liters (.7 USgpm) of oil undercompression = 3450 bar (50000 psi)/second. Maximum overshoot < 8%.

08 Size: Rate of pressure rise with 2,5 liters (.7 USgpm) of oil undercompression = 2900 bar (42000 psi)/second. Maximum overshoot < 10%.

General Description

This Vickers CPF1S relief valve featuresflange mounting for increased designflexibility and reduced external piping.The valve is designed for directmounting on the SAE flange outlet portof a pump. Fewer leak points and SAEflange connections lead to installationswith superior leak resistance.

Pressure relief valves are used to limitor control pressure by directing systemflow to the reservoir when systempressure reaches the setting of thevalve. System overload is therebyprevented and peak pressures which

could damage the pump and actuatingcomponents are eliminated.

The CPF1S valve has excellent dynamicand steady state operatingcharacteristics including stability, fastresponse and low pressure override.CPF relief valves are of two–stagedesign with a fast–acting poppet type main stage for simple, long–lasting andeffective operation. The many availablecontrol options make it possible tochoose the optimum valve model foreach application.

Page 7: Vickers Flange Valves Flange Mounted Pressure Controls · 2013-07-09 · 2 Flange Mounted Valves Continued on next page Model/Size: Relief Valves Function Max. Pressure Max. Flow

7

CPF1* Model Series

3 4 5 8761 2

Model Code

1

2

Valve Function

C - Relief

Mounting Type

PF - Pump flange mounting

Unit Type

1 - Single pressure without vent

Flange Type

S - SAE J518 4-bolt flange standard series code 61 (available in all sizes)

V - SAE J518 4-bolt high pressure series code 62 (size 12 only)

3

4

6

Valve Size

06 - 3/4 inch08 - 1 inch10 - 1 1/4 inch12 - 1 1/2 inch

Pressure Range

A - 10 - 50 bar (145 - 725 psi)B - 10 - 100 bar (145 - 1450 psi)F - 10 - 207 bar (145 - 3000 psi)G - 10 - 275 bar (145 - 4000 psi)

350 bar (5000 psi) - (CPF*V-12models only)

Control Type

W - Screw adjust with locknutH - Handknob adjust without keylockK - Micrometer adjust with keylock

Thread Type(remote control/vent connection)

Blank - SAE-6 O-ring boss port(.5625-18 UNF-2B thd.)

B - BSP-G 1/4 (1/4” BSPF)

Remote Control

Blank - No remote controlRC - Remote Control

Pilot Drain

Blank - Internal drain1 - External drain

Design Number, 20 Series

Subject to change. Installationdimensions unaltered for designnumbers 20 to 29 inclusive.

5 8

9

9 11

7

10

10

11

Page 8: Vickers Flange Valves Flange Mounted Pressure Controls · 2013-07-09 · 2 Flange Mounted Valves Continued on next page Model/Size: Relief Valves Function Max. Pressure Max. Flow

8

Circuit Schematics

%�&���

&�'��� %(%

)

# *

+

&�'��� %(%

%�&���

)+

# *

External drainmodels only.

External drainmodels only.

CPF1S-10/12-*-20 with remote control CPF1S-10/12-P-*-20 without remote control

–10/–12 size 600 l/min (160 USgpm) max. flow

&�,���

&�-���

%(%�&.

)

# *

+&�-���

%(%�&.

&�,���

)+

# *

External drainmodels only.

External drainmodels only.

CPF1S-06/08-*-20 with remote control CPF1S-06/08-P-*-20 without remote control

–06 size 100 l/min (26 USgpm) max. flow–08 size 300 l/min (80 USgpm) max. flow

–06 size 100 l/min (26 USgpm) max. flow–08 size 300 l/min (80 USgpm) max. flow

–10/–12 size 600 l/min (160 USgpm) max. flow

RemoteControl

Gage Port

RemoteControl

Gage Port

Page 9: Vickers Flange Valves Flange Mounted Pressure Controls · 2013-07-09 · 2 Flange Mounted Valves Continued on next page Model/Size: Relief Valves Function Max. Pressure Max. Flow

9

Pressure Curves

Typical Pressure OverrideInternal DrainExternal Drain

Pre

ssur

e D

rop

bar

200 2900

150 2175

100 1450

50 725

0

Flow l/min20 40 60 80 100

5.3 10.6 15.9 21.1 26.4250 3626

Flow USgpm

Pre

ssur

e D

rop

psi

CPF1S-06

Pre

ssur

e D

rop

bar 200

150

100

50

0

250

2900

2175

1450

725

3626

Pre

ssur

e D

rop

psi

Flow l/min50 100 150 200 250 300

13.2 26.4 39.6 52.8 66 79.3Flow USgpm

Typical Pressure OverrideInternal DrainExternal Drain

CPF1S-08

Page 10: Vickers Flange Valves Flange Mounted Pressure Controls · 2013-07-09 · 2 Flange Mounted Valves Continued on next page Model/Size: Relief Valves Function Max. Pressure Max. Flow

10

Typical Pressure OverrideInternal DrainExternal Drain

Pre

ssur

e D

rop

bar

300

200

100

0

Flow l/min

100

400

Flow USgpm

Pre

ssur

e D

rop

psi

CPF1S-10

CPF1S-12CPF1V-12

200 300 400 500 600

26.4 52.8 79.3 105.7 132.1 158.5

4350

2900

1450

5800

Typical Pressure OverrideInternal DrainExternal Drain

Pre

ssur

e D

rop

bar

300

200

100

0

Flow l/min

100

400

Flow USgpm

Pre

ssur

e D

rop

psi

200 300 400 500 600

26.4 52.8 79.3 105.7 132.1 158.5

4350

2900

1450

5800

Page 11: Vickers Flange Valves Flange Mounted Pressure Controls · 2013-07-09 · 2 Flange Mounted Valves Continued on next page Model/Size: Relief Valves Function Max. Pressure Max. Flow

11

Installation Dimensions

CPF1S-06 3/4” Flange - Single Pressure Relief Valvewithout Ventmm (inch)

Pressure port (P port) - ∅ 19,0(.75) SAE Code 61 4-bolt flangeconnection thru

Gage port or remote control port - .5625-18 UNF-2B thd. for 3/8” O.D. tubing - G 1/4 BSP thd.

Pressure adjustment (clockwise rotation increases pressure)

Pressure adjusting lock screw(5/64” hex key req’d. tolock/unlock set screw)

197,8(7.79)

152,8(6.01)

117,3(4.62)

“W” model (screw w/locknut max. extension)

“K” model (micrometer w/keylockmax. extension)

139,6(5.50)

88,8(3.50)

39,6(1.56)

32,5(1.28)

63,4(2.50)

Tank port (T port) -∅ 19,0 (.75) SAE Code 61 4-boltflange connection thru

3,2(.12)

63,0(2.48)

13,6(.54)Ref.

126,6(4.98)

“H” model (handknob) max. extension

External drain port (when ordered per model code) - .4375-20 UNF-2B thd. for 1/4” O.D. tubing - G 1/8 BSP thd.

For key removal

51,6(2.03)

Page 12: Vickers Flange Valves Flange Mounted Pressure Controls · 2013-07-09 · 2 Flange Mounted Valves Continued on next page Model/Size: Relief Valves Function Max. Pressure Max. Flow

12

CPF1S-08 1” Flange - Single Pressure Relief Valvewithout Ventmm (inch)

Pressure adjusting lock screw(5/64” hex key req’d. tolock/unlock set screw)

144,3(5.68)

93,5(3.68)

47,9(1.89)

32,5(1.28)

63,4(2.50)

3,2(.12)

Tank port (T port) - ∅ 25,4 (1.00) SAE Code 614-bolt flange connection thru

197,8(7.79)

152,8(6.01)

“K” model (micrometer w/keylockmax. extension)

For key removal

117,3(4.62)

“W” model (screw w/locknut max. extension)

Pressure adjustment(clockwise rotation increases pressure)

Pressure port (P port) - ∅ 25,4 (1.00) SAE Code 614-bolt flange connection thru

65,0(2.56)

18,6(.73)Ref.

Gage port or remote control port - .5625-18 UNF-2B thd. for 3/8” O.D. tubing - G 1/4 BSP thd.

External drain port (when ordered per model code) - .4375-20 UNF-2B thd. for 1/4” O.D. tubing - G 1/8 BSP thd.

126,6(4.98)

“H” model (handknob) max. extension

51,6(2.03)

Page 13: Vickers Flange Valves Flange Mounted Pressure Controls · 2013-07-09 · 2 Flange Mounted Valves Continued on next page Model/Size: Relief Valves Function Max. Pressure Max. Flow

13

CPF1S-10 11/4” Flange - Single Pressure Relief ValveWithout Ventmm (inch)

186,9(7.36)

Pressure port (P port) - ∅ 31,8 (1.25) SAE Code 614-bolt flange connection thru

Pressure adjusting lock screw(5/64” hex key req’d. tolock/unlock set screw)

136,1(5.36)

67,0(2.64)

38,2(1.51)

75,8(2.98)

Tank port (T port) - ∅ 31,8 (1.25) SAE Code 614-bolt flange connection thru -

Pressure adjustment(clockwise rotation increases pressure)

1,9(.08)

30,0(1.18)Ref.

61,0(2.40)

58,1(2.29)

Gage port or remote control port - .5625-18 UNF-2B thd. for 3/8” O.D. tubing - G 1/4 BSP thd.

External drain port (when ordered per model code) - .4375-20 UNF-2B thd. for 1/4” O.D. tubing - G 1/8 BSP thd.

“K” model (micrometer w/keylockmax. extension)

“W” model (screw w/locknut max. extension)

“H” model (handknob) max. extension

For key removal

189,4(7.46)

144,4(5.69)

109,0(4.29)

118,3(4.66)

Page 14: Vickers Flange Valves Flange Mounted Pressure Controls · 2013-07-09 · 2 Flange Mounted Valves Continued on next page Model/Size: Relief Valves Function Max. Pressure Max. Flow

14

CPF1S-12 – Code 61CPF1V-12 – Code 62 11/2” Flange - Single Pressure Relief ValveWithout Ventmm (inch)

190,2(7.49)

Pressure port (P port) - ∅ 38,1 (1.50) SAE Code 614-bolt flange (For CPF1V-12,Code 62 4-bolt flange)connection thru

Pressure adjusting lock screw(5/64” hex key req’d. tolock/unlock set screw)

Gage port or remote control port - .5625-18 UNF-2B thd. for 3/8” O.D. tubing - G 1/4 BSP thd.

External drain port (when ordered per model code) - .4375-20 UNF-2B thd. for 1/4” O.D. tubing - G 1/8 BSP thd.

Tank port (T port) - ∅ 38,1 (1.50) SAE Code 61 4-boltflange (For CPF1V-12, Code 624-bolt flange) connection thru -

Pressure adjustment(clockwise rotationincreases pressure)

“K” model (micrometer w/keylockmax. extension)

“W” model (screw w/locknut max. extension)

“H” model (handknob)max. extension

For key removal

139,4(5.49)

80,0(3.15)

40,0(1.57)

80,0(3.15)

3,7(.14)

39,0(1.54)Ref.

92,5(3.64)

63,1(2.48)71,1

(2.80)“V” series

118,3(4.66)

109,0(4.29)

189,4(7.46)

144,4(5.69)

Code 62 flange

Code 62 flange

Page 15: Vickers Flange Valves Flange Mounted Pressure Controls · 2013-07-09 · 2 Flange Mounted Valves Continued on next page Model/Size: Relief Valves Function Max. Pressure Max. Flow

15

CPF2*-06/08/10/12-**-20Relief Valve with Venting

Flange Sizes� 06 - 3/4 inch flange� 08 - 1 inch flange� 10 - 11/4 inch flange� 12 - 11/2 inch flange

��������

� Excellent repeatability and stableperformance from cartridgedesign mainstage parts.

� Reduced installed costs andspace requirements.

� Easier installation and servicingof components.

� Pilot design minimizes responsetime and cracking flow whichallows for high pressure stabilitythus increasing system productivity.

��Direct mounting to pump flangereduces potential leak points forsuperior leak resistance.

������� �������� ��������

Maximum flow 100 l/min (26 USgpm) 300 l/min (80 USgpm) 600 l/min (160 USgpm) 600 l/min (160 USgpm)Maximum pressure: P port 275 bar (4000 psi) 275 bar (4000 psi) 275 bar (4000 psi) 275 bar (4000 psi)* T port 207 bar (3000 psi) 207 bar (3000 psi) 207 bar (3000 psi) 207 bar (3000 psi)

����������������

* The CPF2V-12 (code 62 flange) has a max. P port pressure rating of 350 bar (5000 psi).

"�� ��� ������!���

Electrical response is defined as thetime from initiation of power to thesolenoid, to the initiation of pressurerise, with 1,5 liters (.4 USgpm) of oilunder compression:

����� �������#$�%�������������������

100 bar (1450 psi) for DG4V-3S valve210 bar (3045 psi) for DG4V-3 valve AC210 bar (3045 psi) for DG4V-3 valve DC

������� ����!���10/12 Sizes: Rate of pressure rise with2,5 liters (.7 USgpm) of oil undercompression = 2600 bar (37500 psi)/second. Maximum overshoot < 10%.

06 Size: Rate of pressure rise with 2,5 liters (.7 USgpm) of oil undercompression = 3450 bar (50000 psi)/second. Maximum overshoot < 8%.

08 Size: Rate of pressure rise with 2,5 liters (.7 USgpm) of oil undercompression = 2900 bar (42000 psi)/second. Maximum overshoot < 10%.

06 size –@100 l/min (26 USgpm) = DC - 200 ms

AC - 160 ms08 size –@300 l/min (80 USgpm) = DC - 210 ms

AC - 175 ms10/12 size -@300 l/min (80 USgpm) = DC - 180 ms

AC - 160 ms

General Description

This Vickers CPF2S relief valve featuresflange mounting for increased designflexibility and reduced external piping.The valve is designed for directmounting on the SAE flange outlet portof a pump. Fewer leak points and SAEflange connections lead to installationswith superior leak resistance.

Pressure relief valves are used to limitor control pressure by directing systemflow to the reservoir when systempressure reaches the setting of the

valve. System overload is therebyprevented and peak pressures whichcould damage the pump and actuatingcomponents are eliminated.The CPF2S relief valves also provide ameans of limiting system pressure to therelatively low vented pressure bydirecting pilot flow to tank byde-energizing the solenoid operatedDG4V–3 valve.

The CPF2S valve has excellent dynamicand steady state operatingcharacteristics including stability, fast

response and low pressure override.CPF relief valves are of two–stagedesign with a fast–acting poppet typemain stage for simple, long–lasting andeffective operation. The many availablecontrol options make it possible tochoose the optimum valve model foreach application.

Page 16: Vickers Flange Valves Flange Mounted Pressure Controls · 2013-07-09 · 2 Flange Mounted Valves Continued on next page Model/Size: Relief Valves Function Max. Pressure Max. Flow

16

CPF2* Model Series

3 4 5 876 9 101 2 11 12 13 14 15 16 17 18 19 20

Model Code

1

2

Valve Function

C - Relief

Mounting Type

PF - Pump flange mounting

Unit Type

2 - Single pressure with vent

Flange Type

S - SAE J518 4-bolt flange standardseries code 61 (available in all sizes)

V - SAE J518 4-bolt high pressureseries code 62 (size 12 only)

Valve Size

06 - 3/4 inch08 - 1 inch10 - 1 1/4 inch12 - 1 1/2 inch

Pressure Range

A - 10 - 50 bar (145 - 725 psi)B - 10 - 100 bar (145 - 1450 psi)F - 10 - 207 bar (145 - 3000 psi)G - 10 - 275 bar (145 - 4000 psi) -

350 bar (5000 psi) - (CPF2V-12models only)

3

4

5

6

7

8

9

10

15

14

16

17

Control Type

W - Screw adjust with locknutH - Handknob adjust without keyK - Micrometer adjust with keylock

Thread Type(remote control/Vent connection)

Blank - SAE-6 O-ring boss port(.5625-18 UNF-2B thd.)

B - BSP-G 1/4 (1/4” BSPF)

Remote Control

Blank - No remote controlRC - Remote control

Pilot Drain

Blank - Internal drain1 - External drain

Vent Valve

3S - Standard performance3 - High performance Uses OBL type spool/spring. Otherfeatures are optional. Refer to Vickersliterature # GB-C-2015B SolenoidOperated Directional Control Valvescatalog.

Manual Override Options

Solenoid Energization Identification

Electrical Options Flag

Spool Position MonitoringSwitch

Solenoid Type/ElectricalConnections

Indicator Lights

Coil Identification

Tank Rating Pressure

2 - 10 bar (145 psi) for spool positionindicator models.

5 - 100 bar (1450 psi) for standardperformance models, DG4V-3S, with AC or DC solenoids.

6 - 207 bar (3000 psi) for highperformance models, DG4V-3, withAC solenoids.

7 - 207 bar (3000 psi) for highperformance models, DG4V-3 withDC solenoids.

Design Number, 20 series

Subject to change. Installationdimensions unaltered for designnumbers 20 to 29 inclusive.

EN417 – Normally closed,energize to vent relief

11

12

13

18

19

20

Page 17: Vickers Flange Valves Flange Mounted Pressure Controls · 2013-07-09 · 2 Flange Mounted Valves Continued on next page Model/Size: Relief Valves Function Max. Pressure Max. Flow

17

Circuit Schematics

External drainmodels only.

CPF2S-06/08-*-20

–06 size 100 l/min (26 USgpm) max. flow–08 size 300 l/min (80 USgpm) max. flow

0.6 mm

0.7mm

Gage

External drainmodels only.

CPF2S-10/12-*-20 CPF2V-12-*-20

1.0 mm

0.9mm

Gage

–10/–12 size 600 l/min (160 USgpm) max. flow

Page 18: Vickers Flange Valves Flange Mounted Pressure Controls · 2013-07-09 · 2 Flange Mounted Valves Continued on next page Model/Size: Relief Valves Function Max. Pressure Max. Flow

18

Pressure Curves

Typical Pressure OverrideInternal DrainExternal Drain

Vented ∆ P to T

Pre

ssur

e D

rop

bar

Pre

ssur

e D

rop

bar

200 2900

150 2175

100 1450

50 725

0

Flow l/min20 40 60 80 100

5.3 10.6 15.9 21.1 26.4250 3626

Flow USgpm

Flow l/min20 40 60 80 100

0

5.3 10.6 15.9 21.1 26.4Flow USgpm

4

3

2

1

5

58

44

29

15

73

Pre

ssur

e D

rop

psi

Pre

ssur

e D

rop

psi

CPF2S-06

Pre

ssur

e D

rop

bar 200

150

100

50

0

250

2900

2175

1450

725

3626

Pre

ssur

e D

rop

psi

Flow l/min50 100 150 200 250 300

13.2 26.4 39.6 52.8 66 79.3Flow USgpm

Typical Pressure OverrideInternal DrainExternal Drain

Vented ∆ P to T

CPF2S-08

0

Flow l/min50 100 150 200 250 300

Pre

ssur

e D

rop

bar 4

3

2

1

5

58

44

29

15

73

Pre

ssur

e D

rop

psi

13.2 26.4 39.6 52.8 66 79.3Flow USgpm

Typical Pressure OverrideInternal DrainExternal Drain

Typical Pressure OverrideInternal DrainExternal Drain

Page 19: Vickers Flange Valves Flange Mounted Pressure Controls · 2013-07-09 · 2 Flange Mounted Valves Continued on next page Model/Size: Relief Valves Function Max. Pressure Max. Flow

19

Typical Pressure OverrideInternal DrainExternal Drain

Vented ∆ P to T Internal DrainExternal Drain

Pre

ssur

e D

rop

bar

Pre

ssur

e D

rop

bar

300

200

100

0

Flow l/min

100

400

Flow USgpm Flow USgpm

5

145

Pre

ssur

e D

rop

psi

Pre

ssur

e D

rop

psi

CPF2S-10

CPF2S-12CPF2V-12

200 300 400 500 600

26.4 52.8 79.3 105.7 132.1 158.5

4350

2900

1450

5800

0

Flow l/min

100 200 300 400 500 600

10

15

20 290

73

217

26.4 52.8 79.3 105.7 132.1 158.5

Typical Pressure OverrideInternal DrainExternal Drain

Vented ∆ P to T Internal DrainExternal Drain

Pre

ssur

e D

rop

bar

Pre

ssur

e D

rop

bar

300

200

100

0

Flow l/min

100

400

Flow USgpm Flow USgpm

5

145

Pre

ssur

e D

rop

psi

Pre

ssur

e D

rop

psi

200 300 400 500 600

26.4 52.8 79.3 105.7 132.1 158.5

4350

2900

1450

5800

0

Flow l/min

100 200 300 400 500 600

10

15

20 290

73

217

26.4 52.8 79.3 105.7 132.1 158.5

Page 20: Vickers Flange Valves Flange Mounted Pressure Controls · 2013-07-09 · 2 Flange Mounted Valves Continued on next page Model/Size: Relief Valves Function Max. Pressure Max. Flow

20

Installation Dimensions

CPF2S-06 3/4” Flange - Single Pressure Relief ValveWith Ventmm (inch)

Pressure port (P port) - ∅ 19,0 (.75) SAE Code 614-bolt flange connection thru

Gage port or remote control port - .5625-18 UNF-2B thd. for 3/8” O.D. tubing - G 1/4 BSP thd.

Pressure adjustment(clockwise rotationincreases pressure)

Pressure adjusting lock screw(5/64” hex key req’d. tolock/unlock set screw)

197,8(7.79)

152,8(6.01)

117,3(4.62)

“W” model (screw w/locknut max. extension)

“K” model (micrometer w/keylockmax. extension)

External drain port (when ordered per model code) - .4375-20 UNF-2B thd. for 1/4” O.D. tubing - G 1/8 BSP thd.

For key removal

139,6(5.50)

88,8(3.50)

39,6(1.56)

32,5(1.28)

63,4(2.50)

154,3(6.07)

3,2(.12)Ref.

Tank port (T port) - ∅ 19,0 (.75) SAE Code 614-bolt flange connection thru -

62,2(2.45)

126,6(4.98)

13,6(.54)Ref.

63,0(2.48)

62,8(2.47)

142,3(5.60)

“H” model (handknob) max. extension

Page 21: Vickers Flange Valves Flange Mounted Pressure Controls · 2013-07-09 · 2 Flange Mounted Valves Continued on next page Model/Size: Relief Valves Function Max. Pressure Max. Flow

21

CPF2S-08 1” Flange - Single Pressure Relief ValveWith Ventmm (inch)

Pressure port (P port) - ∅ 25,4 (1.00) SAE Code 614-bolt flange connection thru

Gage port or remote control port - .5625-18 UNF-2B thd. for 3/8” O.D. tubing - G 1/4 BSP thd.

Pressure adjustment(clockwise rotationincreases pressure)

Pressure adjusting lock screw(5/64” hex key req’d. tolock/unlock set screw) 197,8

(7.79)

152,8(6.01)

117,3(4.62)

“W” model (screw w/locknut max. extension)

“K” model (micrometer w/keylockmax. extension)

External drain port (when ordered per model code) - .4375-20 UNF-2B thd. for 1/4” O.D. tubing - G 1/8 BSP thd.

For key removal

144,3(5.68)

93,5(3.68)

47,9(1.89)

32,5(1.28)

63,4(2.50)

154,3(6.07)

3,2(.12)Ref.

Tank port (T port) - ∅ 25,4 (1.00) SAE Code 614-bolt flange connection thru

62,2(2.45)

126,6(4.98)

18,6(.73)Ref.

65,0(2.56)

62,8(2.47)

142,3(5.60)

“H” model (handknob) max. extension

Page 22: Vickers Flange Valves Flange Mounted Pressure Controls · 2013-07-09 · 2 Flange Mounted Valves Continued on next page Model/Size: Relief Valves Function Max. Pressure Max. Flow

22

CPF2S-10 11/4” Flange - Single Pressure Relief ValveWith Vent

mm (inch)

Pressure port (P port) - ∅ 31,8 (1.25) SAE Code 614-bolt flange connection thru

Gage port or remote control port - .5625-18 UNF-2B thd. for 3/8” O.D. tubing - G 1/4 BSP thd.

Pressure adjustment(clockwise rotation increases pressure)

Pressure adjusting lock screw(5/64” hex key req’d. to lock/un-lock set screw)

“W” model (screw w/locknut max. extension)

“K” model (micrometer w/keylockmax. extension)

External drain port (when ordered per model code) - .4375-20 UNF-2B thd. for 1/4” O.D. tubing - G 1/8 BSP thd.

For key removal

188,5(7.42)

186,9(7.36)

136,1(5.36)

Tank port (T port) - ∅ 31,8 (1.25) SAE Code 614-bolt flange connection thru

“H” model (handknob) max. extension

67,0(2.64)

38,2(1.51)

75,8(2.98)

61,0(2.40)

58,1(2.29)

30,0(1.18)Ref.

1,9(.08)

167,0(6.57)

155,0(6.10)

118,3(4.66)

109,0(4.29)

189,4(7.46)

144,4(5.69)

Page 23: Vickers Flange Valves Flange Mounted Pressure Controls · 2013-07-09 · 2 Flange Mounted Valves Continued on next page Model/Size: Relief Valves Function Max. Pressure Max. Flow

23

CPF2S-12 – Code 61CPF2V-12 – Code 62 11/2” Flange - Single Pressure Relief ValveWith Ventmm (inch)

191,8(7.55)

Pressure port (P port) - ∅ 38,1 (1.50) SAE Code 614-bolt flange (For CPF1V-12,Code 62 4-bolt flange)connection thru

Pressure adjusting lock screw(5/64” hex key req’d. tolock/unlock set screw)

Gage port or remote control port - .5625-18 UNF-2B thd. for 3/8” O.D. tubing - G 1/4 BSP thd.

External drain port (when ordered per model code) - .4375-20 UNF-2B thd. for 1/4” O.D. tubing - G 1/8 BSP thd.

Tank port (T port) - ∅ 38,1 (1.50) SAE Code 61 4-boltflange (For CPF1V-12, Code 62 4-boltflange) connection thru

Pressure adjustment(clockwise rotationincreases pressure)

“K” model (micrometer w/keylockmax. extension)

“W” model (screw w/locknut max. extension)

“H” model (handknob) max. extension

For key removal

139,4(5.49)

80,0(3.15)

40,0(1.57)

80,0(3.15)

3,7(.14)

39,0(1.54)Ref.

92,5(3.64)

63,1(2.48)71,1

(2.80)“V” series

118,3(4.66)

109,0(4.29)

189,4(7.46)

144,4(5.69)

190,2(7.49)

165,1(6.50)

156,7(6.17)

Code 62 flange

Code 62 flange

Page 24: Vickers Flange Valves Flange Mounted Pressure Controls · 2013-07-09 · 2 Flange Mounted Valves Continued on next page Model/Size: Relief Valves Function Max. Pressure Max. Flow

24

CPF3/4*-06/08/10/12-**-20Bi-Pressure & Tri-Pressure Relief Valves With Venting

Flange Sizes� 06 - 3/4 inch flange� 08 - 1 inch flange� 10 - 11/4 inch flange� 12 - 11/2 inch flange

��������

� Excellent repeatability and stableperformance from cartridgedesign mainstage parts.

� Reduced installed costs andspace requirements.

� Easier installation and servicingof components.

� Pilot design minimizes responsetime and cracking flow whichallows for high pressure stabilitythus increasing system productivity.

��Direct mounting to pump flangereduces potential leak points forsuperior leak resistance.

������� ���&'(���� ���&'(����

Maximum flow 100 l/min (26 USgpm) 300 l/min (80 USgpm) 600 l/min (160 USgpm) 600 l/min (160 USgpm)Maximum pressure: P port 275 bar (4000 psi) 275 bar (4000 psi) 275 bar (4000 psi) 275 bar (4000 psi)* T port 207 bar (3000 psi) 207 bar (3000 psi) 207 bar (3000 psi) 207 bar (3000 psi)

���&'(�������&'(����

* The CPF2V-12 (code 62 flange) has a max. P port pressure rating of 350 bar (5000 psi).

"�� ��� ������!���

Electrical response is defined as thetime from initiation of power to thesolenoid, to the initiation of pressurerise, with 1,5 liters (.4 USgpm) of oilunder compression:

����� �������#$�%�������������������

100 bar (1450 psi) for DG4V-3S valve210 bar (3045 psi) for DG4V-3 valve AC210 bar (3045 psi) for DG4V-3 valve DC

������� ����!���10/12 Sizes: Rate of pressure rise with2,5 liters (.7 USgpm) of oil undercompression = 2600 bar (37500 psi)/second. Maximum overshoot < 10%.

06 Size: Rate of pressure rise with 2,5 liters (.7 USgpm) of oil undercompression = 3450 bar (50000 psi)/second. Maximum overshoot < 8%.

08 Size: Rate of pressure rise with 2,5 liters (.7 USgpm) of oil undercompression = 2900 bar (42000 psi)/second. Maximum overshoot < 10%.

06 size –@100 l/min (26 USgpm) = DC - 200 ms

AC - 160 ms08 size –@300 l/min (80 USgpm) = DC - 210 ms

AC - 175 ms10/12 size -@300 l/min (80 USgpm) = DC - 180 ms

AC - 160 ms

General DescriptionThis Vickers CPF3/4S relief valvefeatures flange mounting for increaseddesign flexibility and reduced externalpiping. The valve is designed for directmounting on the SAE flange outlet portof a pump. Fewer leak points and SAEflange connections lead to installationswith superior leak resistance.Pressure relief valves are used to limitor control pressure by directing systemflow to the reservoir when systempressure reaches the setting of thevalve. System overload is therebyprevented and peak pressures which

could damage the pump and actuatingcomponents are eliminated.This valve features an integrallymounted 3-position solenoid vent valvewhich requires no additional piping.Energizing the “a” or “b” solenoid selectspressure setting (2) or (1) respectively.With neither solenoid energized therelief valve is vented to limit systempressure to the maximum vent pressure.The CPF4S tri-pressure relief valve is apressure control unit which can be usedto electrically select any one of threepreset pressures, or two pressures andvent with the CPF3S.

The CPF3/4S valve has excellentdynamic and steady state operatingcharacteristics including stability, fastresponse and low pressure override.CPF relief valves are of two-stagedesign with a fast–acting poppet typemain stage for simple, long-lasting andeffective operation. The many availablecontrol options make it possible tochoose the optimum valve model foreach application.

Page 25: Vickers Flange Valves Flange Mounted Pressure Controls · 2013-07-09 · 2 Flange Mounted Valves Continued on next page Model/Size: Relief Valves Function Max. Pressure Max. Flow

25

CPF3/4* Model Series

3 4 5 76 101 2 11 12 13 14 15 16 17 18 19 20

Model Code

1

2

Valve Function

C - Relief

Mounting Type

PF - Pump flange mounting

Unit Type

3 - Bi-pressure with max. pressureoverride

4 - Tri-pressure

Flange Type

S - SAE J518 4-bolt flange standardseries code 61 (available all sizes)

V - SAE J518 4-bolt high pressureseries code 62 (size 12 only)

Valve Size

06 - 3/4 inch08 - 1 inch10 - 1 1/4 inch12 - 1 1/2 inch

Head 1 Pressure Range

A - 10 - 50 bar (145 - 725 psi)B - 10 - 100 bar (145 - 1450 psi)F - 10 - 207 bar (145 - 3000 psi)G - 10 - 275 bar (145 - 4000 psi)

350 bar (5000 psi) - (CPF*V-12models only)

3

4

5

6

8

9

10

15

14

Head 2 Pressure Range

A - 10 - 50 bar (145 - 725 psi)B - 10 - 100 bar (145 - 1450 psi)F - 10 - 207 bar (145 - 3000 psi)G - 10 - 275 bar (145 - 4000 psi)

350 bar (5000 psi) - (CPF*V-12models only)

Head 3 Pressure Range

A - 10 - 50 bar (145 - 725 psi)B - 10 - 100 bar (145 - 1450 psi)F - 10 - 207 bar (145 - 3000 psi)G - 10 - 275 bar (145 - 4000 psi)

350 bar (5000 psi) - (CPF*V-12models only)

Note: Head 3 is the maximum pressure override

adjustment. The pressure range selection should be

at least 17 bar (250 psi) higher than those for Heads

1 and 2.

Control Type

W - Screw adjust with locknutH - Handknob adjust without keyK - Micrometer adjust with keylock

Thread Type

Remote Control/Vent ConnectionBlank - SAE-6 O-ring boss port

(.5625-18 UNF-2B thd.)B - BSP-G 1/4 (1/4” BSPF)

Remote Control

Blank - No remote controlRC - Remote Control

Pilot Drain

Blank - Internal drain1 - External drain

Vent Valve

3S - Standard performance3 - High performance Uses 0C type spool/spring for CPF3 and2C type spool/spring for CPF4; otherfeatures are optional. Refer to Vickersliterature # GB-C-2015B SolenoidOperated Directional Control Valvescatalog.

Manual Override Options

Solenoid Energization Identification

Electrical Options Flag

Spool Position MonitoringSwitch

Solenoid Type/ElectricalConnections

Indicator Lights

Coil Voltage Identification

Tank Rating Pressure

2 - 10 bar (145 psi) for spool positionindicator models.

5 - 100 bar (1450 psi) for standardperformance models, DG4V-3S, with AC or DC solenoids.

6 - 207 bar (3000 psi) for highperformance models, DG4V-3, withAC solenoids.

7 - 207 bar (3000 psi) for highperformance models, DG4V-3 withDC solenoids.

Design Number, 20 Series

Subject to change. Installationdimensions unaltered for designnumbers 20 to 29 inclusive.

16

17

8 9 21 22

18

19

20

21

22

11

12

137

Page 26: Vickers Flange Valves Flange Mounted Pressure Controls · 2013-07-09 · 2 Flange Mounted Valves Continued on next page Model/Size: Relief Valves Function Max. Pressure Max. Flow

26

Circuit Schematics

External drainmodels only.

CPF3S-06/08-*-20

–06 size 100 l/min (26 USgpm) max. flow–08 size 300 l/min (80 USgpm) max. flow

0.6 mm

0.7mm

Gage

CPF3S-10/12-*-20 CPF3V-12-*-20

1.0 mm

0.9 mm

Gage

–10/–12 size 600 l/min (160 USgpm) max. flow

GageT T

External drainmodels only.

P P

CPF4S-06/08-*-20

0.7mm

0.6 mm

Head 2 Head 1

Head 3

Head 2 Head 1

Head 3

–06 size 100 l/min (26 USgpm) max. flow–08 size 300 l/min (80 USgpm) max. flow

1.0 mm

0.9 mm

T T

P P

Gage

Head 2 Head 1

Head 3

Head 2 Head 1

Head 3

External drainmodels only.

External drainmodels only.

–10/–12 size 600 l/min (160 USgpm) max. flow

CPF4S-10/12-*-20 CPF4V-12-*-20

Page 27: Vickers Flange Valves Flange Mounted Pressure Controls · 2013-07-09 · 2 Flange Mounted Valves Continued on next page Model/Size: Relief Valves Function Max. Pressure Max. Flow

27

Pressure Curves

Typical Pressure OverrideInternal DrainExternal Drain

Vented ∆ P to T

Pre

ssur

e D

rop

bar

Pre

ssur

e D

rop

bar

200 2900

150 2175

100 1450

50 725

0

Flow l/min20 40 60 80 100

5.3 10.6 15.9 21.1 26.4250 3626

Flow USgpm

Flow l/min20 40 60 80 100

0

5.3 10.6 15.9 21.1 26.4Flow USgpm

4

3

2

1

5

58

44

29

15

73

Pre

ssur

e D

rop

psi

Pre

ssur

e D

rop

psi

CPF3/4S-06

Pre

ssur

e D

rop

bar 200

150

100

50

0

250

2900

2175

1450

725

3626

Pre

ssur

e D

rop

psi

Flow l/min50 100 150 200 250 300

13.2 26.4 39.6 52.8 66 79.3Flow USgpm

Typical Pressure OverrideInternal DrainExternal Drain

Vented ∆ P to T

CPF3/4S-08

0

Flow l/min50 100 150 200 250 300

Pre

ssur

e D

rop

bar 4

3

2

1

5

58

44

29

15

73

Pre

ssur

e D

rop

psi

13.2 26.4 39.6 52.8 66 79.3Flow USgpm

Typical Pressure OverrideInternal DrainExternal Drain

Typical Pressure OverrideInternal DrainExternal Drain

Page 28: Vickers Flange Valves Flange Mounted Pressure Controls · 2013-07-09 · 2 Flange Mounted Valves Continued on next page Model/Size: Relief Valves Function Max. Pressure Max. Flow

28

Typical Pressure OverrideInternal DrainExternal Drain

Vented ∆ P to T Internal DrainExternal Drain

Pre

ssur

e D

rop

bar

Pre

ssur

e D

rop

bar

300

200

100

0

Flow l/min

100

400

Flow USgpm Flow USgpm

5

145

Pre

ssur

e D

rop

psi

Pre

ssur

e D

rop

psi

CPF3/4S-10

CPF3/4S-12CPF3/4V-12

200 300 400 500 600

26.4 52.8 79.3 105.7 132.1 158.5

4350

2900

1450

5800

0

Flow l/min

100 200 300 400 500 600

10

15

20 290

73

217

26.4 52.8 79.3 105.7 132.1 158.5

Typical Pressure OverrideInternal DrainExternal Drain

Vented ∆ P to T Internal DrainExternal Drain

Pre

ssur

e D

rop

bar

Pre

ssur

e D

rop

bar

300

200

100

0

Flow l/min

100

400

Flow USgpm Flow USgpm

5

145

Pre

ssur

e D

rop

psi

Pre

ssur

e D

rop

psi

200 300 400 500 600

26.4 52.8 79.3 105.7 132.1 158.5

4350

2900

1450

5800

0

Flow l/min

100 200 300 400 500 600

10

15

20 290

73

217

26.4 52.8 79.3 105.7 132.1 158.5

Page 29: Vickers Flange Valves Flange Mounted Pressure Controls · 2013-07-09 · 2 Flange Mounted Valves Continued on next page Model/Size: Relief Valves Function Max. Pressure Max. Flow

29

Installation Dimensions

CPF3/4S-06 3/4” Flange - Bi-Pressure With Safety & Tri-Pressure Relief Valve

mm (inch)

Pressure port (P port) -∅ 19,0 (.75) SAE Code 61 4-bolt flange connection

Gage port or remote control port - .5625-18 UNF-2B thd. for 3/8” O.D. tubing - G 1/4 BSP thd.

Pressure adjustment (clockwise rotation increases pressure)

Pressure adjusting lockscrew (5/64” hex key req’d.to lock/unlock set screw)

197,8(7.79)

152,8(6.01)

117,3(4.62)

“W” model (screw w/locknut max. extension)

“K” model (micrometer w/keylockmax. extension)

External drain port (see model code) - .4375-20 UNF-2B thd. for 1/4” O.D. tubing - G 1/8 BSP thd.

For key removal139,6(5.50)

88,8(3.50)

39,6(1.56)

32,5(1.28)

63,4(2.50)

198,7(7.82)

3,2(.12)

Tank port (T port) - ∅ 19,0 (.75) SAE Code 614-bolt flange connection thru -

133,0(5.23)

126,6(4.98)

13,6(.54)Ref.

63,0(2.48)

51,5(2.03)

186,7(7.35)

“H” model (handknob) max. extension

Head #1Head #3

Head #2

sol.

Bso

l. A

Page 30: Vickers Flange Valves Flange Mounted Pressure Controls · 2013-07-09 · 2 Flange Mounted Valves Continued on next page Model/Size: Relief Valves Function Max. Pressure Max. Flow

30

CPF3/4S-08 1” Flange - Bi-Pressure With Safety & Tri-Pressure Relief Valve

mm (inch)

Pressure port (P port) - ∅ 25,4(1.00) SAE Code 61 4-bolt flangeconnection

Gage port or remote controlport - .5625-18 UNF-2B thd. for3/8” O.D. tubing - G 1/4 BSP thd.

Pressure adjustment (clockwise rotation increases pressure)

Pressure adjusting lock screw(5/64” hex key req’d. to lock/unlock set screw) 197,8

(7.79)

152,8(6.01)

117,3(4.62)

“W” model (screw w/locknut max. extension)

“K” model (micrometer w/keylockmax. extension)

External drain port (see model code) – .4375-20 UNF-2Bthd. for 1/4” O.D. tubing - G 1/8 BSP thd.

For key removal

144,3(5.68)

93,5(3.68)

47,9(1.89)

32,5(1.28)

63,4(2.50)

198,7(7.82)

3,2(.12)

Tank port (T port) - ∅ 25,4 (1.00) SAE Code61 4-bolt flange connection thru -

133,0(5.23)

126,6(4.98)

18,6(.73)Ref.

65,0(2.56)

51,5(2.03)

186,7(7.35)

“H” model (handknob) max. extension

Head #1Head #3

Head #2

sol.

Bso

l. A

Page 31: Vickers Flange Valves Flange Mounted Pressure Controls · 2013-07-09 · 2 Flange Mounted Valves Continued on next page Model/Size: Relief Valves Function Max. Pressure Max. Flow

31

CPF3/4S-10 11/4” Flange - Bi-Pressure With Safety &Tri-Pressure Relief Valve

mm (inch)

Pressure port (P port) - ∅ 31,8 (1.25) SAE Code 614-bolt flange connection thru

Gage port or remotecontrol port - .5625-18 UNF-2B thd. for 3/8” tubing - G 1/4 BSP thd.

Pressure adjustment (clockwise rotation increases pressure)

Pressure adjusting lock screw(5/64” hex key req’d. to lock/unlock set screw)

“W” model (screw w/locknut max. extension)

“K” model (micrometer w/keylockmax. extension)

External drain port (see model code)-.4375-20 UNF-2B thd. for 1/4” O.D. tubing - G 1/8 BSP thd.

For key removal

186,9(7.36)

188,5(7.36)

136,1(5.36)

Tank port (T port) - ∅ 31,8 (1.25) SAECode 61 4-bolt flangeconnection thru

“H” model (handknob) max. extension

67,0(2.64)

61,0(2.40)

58,1(2.29)

1,9(.08)

199,4(7.85)

118,3(4.66)

109,0(4.29)

189,4(7.46)

144,4(5.69)

Head #1 Head #3

Head #2

38,2(1.51)

75,8(2.98)

30,0(1.18)Ref.

116,7(4.60)

211,4(8.32)

sol.

Bso

l. A

Page 32: Vickers Flange Valves Flange Mounted Pressure Controls · 2013-07-09 · 2 Flange Mounted Valves Continued on next page Model/Size: Relief Valves Function Max. Pressure Max. Flow

32

CPF3/4S-12 – Code 61CPF3/4V-12 – Code 62 11/2” Flange - Bi-Pressure With Safety & Tri-Pressure Relief Valve

mm (inch)191,8(7.55)

Pressure port (P port) - ∅ 38,1 (1.50) SAE Code 614-bolt flange (For CPF1V-12,Code 62 4-bolt flange)connection thru

Pressure adjusting lock screw(5/64” hex key req’d. tolock/unlock set screw)

Gage port or remote controlport - .5625-18 UNF-2B thd. for 3/8” O.D. tubing - G 1/4 BSP thd.

External drain port (see model code) -.4375-20 UNF-2B thd. for 1/4” O.D. tubing-G 1/8 BSP thd.

Tank port (T port) - ∅ 38,1 (1.50) SAE Code61 4-bolt flange (For CPF1V-12,Code 62 4-bolt flange) connectionthru -

Pressure adjustment (clockwise rotation increases pressure)

“K” model (micrometer w/keylockmax. extension)

“W” model (screw w/locknut max. extension)

“H” model (handknob) max. extension

For key removal

139,4(5.49)

80,0(3.15)

39,6(1.56)

79,6(3.13)

3,7(.14)

39,0(1.54)Ref.

92,5(3.64)

63,1(2.48)71,1

(2.80)“V” series

118,3(4.66)

109,0(4.29)

189,4(7.46)

144,4(5.69)

190,2(7.49)

213,2(8.39)

117,5(4.63)

201,2(7.92)

Head #1 Head #3

Head #2

3,3(.13)

“V” series

40,0(1.57)

“V” series

80,0(3.15)

“V” series

Code 62 flange

Code 62 flange

sol.

Bso

l. A

Page 33: Vickers Flange Valves Flange Mounted Pressure Controls · 2013-07-09 · 2 Flange Mounted Valves Continued on next page Model/Size: Relief Valves Function Max. Pressure Max. Flow

33

UPF1*-(**)-06/08/10/12-**-20Unloading Valves - Without Vent

Flange Sizes� 06 - 3/4 inch flange� 08 - 1 inch flange� 10 - 11/4 inch flange� 12 - 11/2 inch flange

��������

� Excellent repeatability and stableperformance from cartridgedesign mainstage parts.

� Reduced installed costs andspace requirements.

� Easier installation and servicingof components.

� Pilot design minimizes responsetime and cracking flow whichallows for high pressure stabilitythus increasing system productivity.

��Direct mounting to pump flangereduces potential leak points forsuperior leak resistance.

��/��������� � ����������������

���� ������ ���

������� )������� )�������

Maximum flow: 100 l/min (26 USgpm) 300 l/min (80 USgpm) 600 l/min (160 USgpm) 600 l/min (160 USgpm)

External drain 300 l/min (80 USgpm) 300 l/min (80 USgpm)

Internal drain 151 l/min (40 USgpm) 151 l/min (40 USgpm)

Maximum pressure:

P port 275 bar (4000 psi) 275 bar (4000 psi) 275 bar (4000 psi) 275 bar (4000 psi)*

T port 207 bar (3000 psi) 207 bar (3000 psi) 207 bar (3000 psi) 207 bar (3000 psi)

)�������*)�������

* The UPF1V-12 (code 62 flange) has a max. P port pressure rating of 350 bar (5000 psi).

General Description

This Vickers UPF1S unloading valvefeatures flange mounting for increaseddesign flexibility and reduced externalpiping. The valve is designed for directmounting on the SAE flange outlet portof a pump. Fewer leak points and SAEflange connections lead to installationswith superior leak resistance.

0��� ����� ����� ���������

������ ����� �����������������

�������������� �������$������

��� � �������� ������������

���������������������������

���������� ����������������������

������� ������ �������������

�� ������������� ������ �� ������

����������� ������������������������

���������������������� ����� ����

����������� ������������������ ����

�������������������������������� �

�������������������������

In construction, an unloading valvecontains a compound relief valve with apoppet-type main stage, an integral(when ordered per model code) checkvalve to prevent reverse flow from theaccumulator, and a pressure operatedplunger which vents the relief valve atthe selected pressure.

����0��%1�� ����� ���!���������� ��

����� ���� ������ ��

�� � ���������������� ������ �

��������� ��������������������������

UPF valves are of two–stage designwith a fast–acting poppet type main stage for simple, long–lasting andeffective operation. The many availablecontrol options make it possible tochoose the optimum valve model foreach application.

Page 34: Vickers Flange Valves Flange Mounted Pressure Controls · 2013-07-09 · 2 Flange Mounted Valves Continued on next page Model/Size: Relief Valves Function Max. Pressure Max. Flow

34

UPF1* Model Series

3 4 5 8761 2

Model Code

1

2

Valve Function

U - Unloading valve

Mounting Type

PF - Pump flange mounting

Unit type

1 - Single pressure without vent

Flange Type

S - SAE J518 4-bolt flange standard series code 61 (available in all sizes)

V - SAE J518 4-bolt high pressure series code 62 (size 12 only)

Integral Check Valve*(0,3 bar (5 psi) cracking pressure only)

Blank - Without check valveC - With right angle check - Not

available with UPF1V-12CL - With In-line check

3

4

7

Valve Size

06 - 3/4 inch08 - 1 inch10 - 1 1/4 inch12 - 1 1/2 inch

Pressure Adjustment Range

A - 9 - 70 bar (130 - 1000 psi)B - 9 - 125 bar (130 - 1800 psi)F - 9 - 245 bar (130 - 3600 psi)G - 9 - 275 bar (130 - 4000 psi)

350 bar (5000 psi) - (UPF1V-12models only)

Control Type

W - Screw adjust with locknutK - Micrometer adjust with keylockM - Micrometer adjust w/o keylock

Thread Type(remote control/vent connection)

Blank - SAE-6 O-ring boss port(.5625-18 UNF-2B thd.)

B - BSP-G 1/4 (1/4” BSPF)

Accumulator Sense Port

Blank - Internal sense portP - External sense port (not

available on models w/integralcheck)

Pilot Drain

Blank - Internal drain1 - External drain

Design Number, 20 series

Subject to change. Installationdimensions unaltered for designnumbers 20 to 29 inclusive.

6 9

9 10

8

10

11 12

5

11

12

* The integral check valve is not the same as the DCPFS right angle check valve.

Page 35: Vickers Flange Valves Flange Mounted Pressure Controls · 2013-07-09 · 2 Flange Mounted Valves Continued on next page Model/Size: Relief Valves Function Max. Pressure Max. Flow

35

Circuit Schematics

&�,���

&�-���

With externaldrain models only.

UPF1S-C*-06/08-*-20 with check valve UPF1S-06/08-(P)-*-20 without check valve

–06 size 100 l/min (26 USgpm) max. flow–08 size 300 l/min (80 USgpm) external drain150 l/min (40 USgpm) internal drain max. flow

Inlet

External drain

External pilotpressure port

External drain

With externaldrain models only.

Inlet

&�,���

&�-���

UPF1S-C*-10/12-*-20 with check valve UPF1S-10/12-(P)-*-20 without check valve

–10/-12 sizes 600 l/min (160 USgpm) max. flow

%�&���

&�'���

AccumulatorpressureGage port

Outlet

With externaldrain models only.

Inlet

External drain

AccumulatorpressureGage port

Outlet

%�&���

&�'���

Outlet

External pilotpressure port

External drain

With externaldrain models only.

Inlet

Outlet

Page 36: Vickers Flange Valves Flange Mounted Pressure Controls · 2013-07-09 · 2 Flange Mounted Valves Continued on next page Model/Size: Relief Valves Function Max. Pressure Max. Flow

36

Pressure Curves

Unload vs Recharge ∆ P Pressure @100 l/min (26 USgpm) with integral check valve as supplied.Internal DrainExternal Drain

Vented ∆ P to T Internal DrainExternal Drain

UPF1S-06

∆ P P to P With 0,34 bar (5 psi) Check Valve

0

6,8

13,8

20,6

27,5

34,5

100

200

300

400

500

34,5 70 103 138 172 207 241 276Unload Pressure - bar

Unload Pressure - psi500 1000 1500 2000 2500 3000 3500 4000

Pre

ssur

e D

rop

- ba

r

Pre

ssur

e D

rop

- ps

i

Flow - l/min

Flow - USgpm

0

5.3 10.6 15.9 21.1 26.4

20 40 60 80 100

1

2

3

4

5

14.5

29

43.5

58

72.5

Pre

ssur

e D

rop

- ba

r

Pre

ssur

e D

rop

- ps

i

Flow - l/min

Flow - USgpm

0

5.3 10.6 15.9 21.1 26.4

20 40 60 80 100

1

2

3

4

5

14.5

29

43.5

58

72.5

Unload vs Recharge ∆ P Pressure with integral checkvalve as supplied.Internal Drain @150 l/min (40 USgpm)External Drain @300 l/min (80 USgpm)

Vented ∆ P P to T Internal DrainExternal Drain

UPF1S-08

∆ P P to P With 0,34 bar (5 psi) Check Valve

0

6,8

13,8

20,6

27,5

34,5

100

200

300

400

500

34,5 70 103 138 172 207 241 276Unload Pressure - bar

Unload Pressure - psi500 1000 1500 2000 2500 3000 3500 4000

Pre

ssur

e D

rop

- ba

r

Pre

ssur

e D

rop

- ps

i

Flow - l/min

Flow - USgpm

0

13.2 26.4 39.6 52.8 66

50 100 150 200 250

2

4

6

8

1079.3

300

29

58

87

116

145

Rec

harg

e P

ress

ure

-

bar

0

Flow l/min50 100 150 200 250 300

Pre

ssur

e D

rop

- ba

r 4

3

2

1

5

58

44

29

15

7313.2 26.4 39.6 52.8 66 79.3

Flow USgpm

∆ P

Rec

harg

e P

ress

ure

-

psi

∆ P

Pre

ssur

e D

rop

- ps

i

Rec

harg

e P

ress

ure

-

bar

∆ P

Rec

harg

e P

ress

ure

-

psi

∆ P

“C” right anglecheck

“CL” in-linecheck

“CL” in-linecheck

“C” right anglecheck

Page 37: Vickers Flange Valves Flange Mounted Pressure Controls · 2013-07-09 · 2 Flange Mounted Valves Continued on next page Model/Size: Relief Valves Function Max. Pressure Max. Flow

37

Pressure Curves

Vented ∆ P P to T Internal Drain @600 l/min (160 USgpm)External Drain @600 l/min (160 USgpm)

UPF1S-10

∆ P P to P With 0,34 bar (5 psi) Check Valve

0

6,8

13,8

20,6

27,5

34,5

100

200

300

400

500

34,5 70 103 138 172 207 241 276Unload Pressure - bar

Unload Pressure - psi500 1000 1500 2000 2500 3000 3500 4000

Pre

ssur

e D

rop

- ba

r

Pre

ssur

e D

rop

- ps

i

Flow - l/min

Flow - USgpm

0 100 200 300 400 500

26.4 52.8 79.3 105.6 132

5

10

15

20

72.5

145

218

290

Pre

ssur

e D

rop

- ba

r

UPF1S(V)-12Unload vs Recharge ∆ P Pressure with integral checkvalve as supplied.Internal Drain @600 l/min (160 USgpm)External Drain @600 l/min (160 USgpm)

41,4 600

600

158.4

Pre

ssur

e D

rop

- ps

i

Flow - l/min

Flow - USgpm

0 100 200 300 400 500

26.4 52.8 79.3 105.6 132

5

10

15

20

72.5

145

218

290

600

158.4

Vented ∆ P P to T Internal Drain @600 l/min (160 USgpm)External Drain @600 l/min (160 USgpm)

∆ P P to P With 0,34 bar (5 psi) Check Valve

0

6,8

13,8

20,6

27,5

34,5

100

200

300

400

500

34,5 70 103 138 172 207 241 276Unload Pressure - bar

Unload Pressure - psi500 1000 1500 2000 2500 3000 3500 4000

Pre

ssur

e D

rop

- ba

r

Pre

ssur

e D

rop

- ps

i

Flow - l/min

Flow - USgpm

0 100 200 300 400 500

26.4 52.8 79.3 105.6 132

5

10

15

20

72.5

145

218

290

Pre

ssur

e D

rop

- ba

r

Unload vs Recharge ∆ P Pressure with integral checkvalve as supplied.Internal Drain @600 l/min (160 USgpm)External Drain @600 l/min (160 USgpm)

41,4 600

600

158.4

Pre

ssur

e D

rop

- ps

i

Flow - l/min

Flow - USgpm

0 100 200 300 400 500

26.4 52.8 79.3 105.6 132

5

10

15

20

72.5

145

218

290

600

158.4

Rec

harg

e P

ress

ure

-

bar

∆ P

Rec

harg

e P

ress

ure

-

psi

∆ P

Rec

harg

e P

ress

ure

-

bar

∆ P

Rec

harg

e P

ress

ure

-

psi

∆ P

“C” right angle check

“CL” in-line check

“CL” in-line check

“C” right angle check

Page 38: Vickers Flange Valves Flange Mounted Pressure Controls · 2013-07-09 · 2 Flange Mounted Valves Continued on next page Model/Size: Relief Valves Function Max. Pressure Max. Flow

38

Installation Dimensions

UPF1S-06 3/4” Flange - Unloading Valve without Vent or Check

mm (inch)

P port ∅ 19,0 (.75) SAE Code61 4-bolt flange connection

Accumulator pressure gage port or externalpilot port (models w/o check valve) - .5625-18 UNF-2B thd. for 3/8” O.D. tubing - G 1/4 BSP thd.

“W” model (screw w/locknutmax. extension)

140,3(5.53)

For cap removal

T port ∅ 19,0 (.75) SAE Code 61 4-bolt flangeconnection

P port (inlet)

32,5(1.28)

63,4(2.50)

39,6(1.56) 3,2

(.12)

88,8(3.50)

P port (outlet)

13,6(.54)Ref.

63,0(2.48)

108,7(4.28)

152,2(5.99)

For key removal

171,7(6.76)

155,7(6.13)

128,7(5.07)

“M” model (with micrometer adjust max. extension)

“K” model (key lock withmicrometer adjust max. extension)

External drain port - .5625-18 UNF-2B thd. for 3/8” O.D. tubing - G 1/4 BSP thd.

Page 39: Vickers Flange Valves Flange Mounted Pressure Controls · 2013-07-09 · 2 Flange Mounted Valves Continued on next page Model/Size: Relief Valves Function Max. Pressure Max. Flow

39

Installation Dimensions

UPF1S-C*-06 3/4” Flange - Unloading Valve with Check without Vent

mm (inch)

140,3(5.53)

For key removal

171,7(6.76)

155,7(6.13)

128,7(5.07)

“M” model (withmicrometer adjustmax. extension)

“K” model (key lock withmicrometer adjust max.extension)

“W” model (screw w/locknut max. extension)

For cap removal

108,7(4.28)

152,2(5.99)

Accumulator pressure age port or external pilot port (models w/o check valve) - .5625-18 UNF-2B thd. for 3/8” O.D. tubing - G 1/4 BSP thd.

P port ∅ 19,0 (.75) SAE Code 614-bolt flange connection

T port ∅ 19,0 (.75) SAE Code 61 4-bolt flangeconnection thru

P port (inlet)

32,5(1.28)

63,4(2.50)

39,6(1.56) 3,2

(.12)

88,8(3.50)

P port (outlet)

65,0(2.58)

90,4(3.58)

166,5(6.55)

Gage port .5625-18 UNF-2B thd. for 3/8” tubing G 1/4 BSP thd.

123,4(4.86)

212,8(8.38)98,4

(3.88)69,8

(2.75)

13,6(.54)Ref.

82,6(3.25)

41,3(1.62) 135,4

(5.33)

External drain port - .5625-18 UNF-2B thd. for 3/8” O.D. tubing - G 1/4 BSP thd.

“C” ModelsRight Angle Check

“CL” ModelsIn-line Check

3,2(.12)

140,3(5.53)

88,8(3.50)

39,6(1.56)

T port ∅ 19,0 (.75) SAE Code 61 4-bolt flangeconnection thru

P port (inlet)

114,2(4.50)

63,4(2.50)

32,5(1.28)

Page 40: Vickers Flange Valves Flange Mounted Pressure Controls · 2013-07-09 · 2 Flange Mounted Valves Continued on next page Model/Size: Relief Valves Function Max. Pressure Max. Flow

40

UPF1S-08 1” Flange - Unloading Valve without Vent or Checkmm (inch)

P port ∅ 25,4 (1.00) SAE Code61 4-bolt flange connection

Accumulator pressure gage port or externalpilot port (models w/o check valve) - .5625-18 UNF-2B thd. for 3/8” O.D. tubing - G 1/4 BSP thd.

“W” model (screw w/locknutmax. extension)

145,0(5.71)

For cap removal

T port ∅ 25,4 (1.00) SAE Code 61 4-bolt flangeconnection

P port (inlet)

32,5(1.28)

63,4(2.50)

47,9(1.89) 3,2

(.12)

93,5(3.50)

P port (outlet)

18,6(.73)Ref.

63,0(2.48)

108,7(4.28)

152,2(5.99)

For key removal

171,7(6.76)

155,7(6.13)

128,7(5.07)

“M” model (with micrometer adjust max. extension)

“K” model (key lock withmicrometer adjust max. extension)

External drain port - .5625-18 UNF-2B thd. for 3/8” O.D. tubing - G 1/4 BSP thd.

Page 41: Vickers Flange Valves Flange Mounted Pressure Controls · 2013-07-09 · 2 Flange Mounted Valves Continued on next page Model/Size: Relief Valves Function Max. Pressure Max. Flow

41

UPF1S-C*-08 1” Flange - Unloading Valve with Check without Ventmm (inch)

145,0(5.71)

For key removal

171,7(6.76)

155,7(6.13)

128,7(5.07)

“M” model (withmicrometer adjustmax. extension)

“K” model (key lock withmicrometer adjust max.extension)

“W” model (screw w/locknutmax. extension)

For cap removal

108,7(4.28)

152,2(5.99)

Accumulator pressure gage port or external pilot port (models w/o check valve) - .5625-18 UNF-2B thd. for 3/8” O.D. tubing - G 1/4 BSP thd.

P port ∅ 25,4 (1.00) SAE Code61 4-bolt flange connection

T port ∅ 25,4 (1.00)SAE Code 61 4-boltflange connection

P port (inlet)

32,5(1.28)

63,4(2.50)

47,9(1.89)

3,2(.12)

93,5(3.68)

P port (outlet)

65,0(2.58)

90,4(3.58)

166,5(6.55)

Gage port .5625-18 UNF-2B thd. for 3/8” tubing G 1/4 BSP thd.

123,4(4.86)

214,1(8.43)

98,4(3.88) 69,8

(2.75)

18,6(.73)Ref.

82,6(3.25)

41,3(1.62) 135,4

(5.33)

External drain port - .5625-18 UNF-2B thd. for 3/8” O.D. tubing - G 1/4 BSP thd.

“CL” ModelsIn-line Check

3,2(.12)

T port ∅ 25,4 (1.00) SAE Code 61 4-bolt flangeconnection thru

P port (inlet)

63,4(2.50)

32,5(1.28)

“C” ModelsRight Angle Check

145,0(5.71)

93,5(3.68)

47,9(1.89)

123,4(4.86)

Page 42: Vickers Flange Valves Flange Mounted Pressure Controls · 2013-07-09 · 2 Flange Mounted Valves Continued on next page Model/Size: Relief Valves Function Max. Pressure Max. Flow

42

UPF1S-10 11/4” Flange - Unloading Valve Without Vent or Checkmm (inch)

P port ∅ 31,8 (1.25) SAECode 61 4-bolt flangeconnection thru

Accumulator pressure gage port or externalpilot port (models w/o check valve) - .5625-18 UNF-2B thd. for 3/8” O.D. tubing - G 1/4 BSP thd.

“W” model (screww/locknut max.extension)

196,9(7.36)

For cap removal

T port ∅ 31,8(1.25) SAE Code61 4-bolt flangeconnection

P port (inlet)

38,3(1.51)

75,8(2.98)

67,0(2.64) 1,9

(.08)

136,1(5.36)

P port (outlet)

30,0(1.18)

108,7(4.28)

152,2(5.99)

For key removal

171,7(6.76)

155,7(6.13)

128,7(5.07)

“M” model (with micrometer adjust max. extension)

“K” model (key lock with micrometeradjust max. extension)

58,1(2.29)

External drain port - .5625-18 UNF-2B thd. for 3/8” O.D. tubing - G 1/4 BSP thd.

Page 43: Vickers Flange Valves Flange Mounted Pressure Controls · 2013-07-09 · 2 Flange Mounted Valves Continued on next page Model/Size: Relief Valves Function Max. Pressure Max. Flow

43

UPF1S-C*-10 11/4” Flange - Unloading Valve with Check without Ventmm (inch)

196,9(7.36)

For key removal

155,7(6.13)

128,7(5.07)

“W” model (screw w/locknutmax. extension)

For cap removal

108,7(4.28)

152,2(5.99)

Accumulator pressure gage port or external pilot port (models w/o check valve) - .5625-18 UNF-2B thd. for 3/8” O.D. tubing - G 1/4 BSP thd.

P port ∅ 31,8 (1.25) SAE Code 614-bolt flange connection

T port ∅ 31,8(1.25) SAE Code61 4-bolt flangeconnection

P port (inlet)

221,7(8.73)

Gage port .5625-18 UNF-2B thd. for 3/8” tubingG 1/4 BSP thd.

152,0(5.98)

261,8(10.31)

30,0(1.18)Ref.

97,0(3.82)

76,9(3.03)

67,0(2.64) 1,9

(.08)

136,1(5.36)

P port (outlet)

111,9(4.41)

171,7(6.76)

“M” model (withmicrometer adjustmax. extension)

“K” model (key lock withmicrometer adjust max.extension)

38,3(1.51)

75,8(2.98)

132,5(5.22)

48,5(1.91)

58,1(2.29)

152,8(6.02)

77,8(3.06)

External drain port - .5625-18 UNF-2B thd. for 3/8” O.D. tubing - G 1/4 BSP thd.

“CL” ModelsIn-line Check

1,9(.08)

196,9(7.36)136,1

(5.36)67,0(2.64)

145,8(5.74)

75,8(2.98)

38,3(1.51)

“C” ModelsRight Angle Check

T port ∅ 31,8(1.25) SAE Code61 4-bolt flangeconnection

P port (inlet)

Page 44: Vickers Flange Valves Flange Mounted Pressure Controls · 2013-07-09 · 2 Flange Mounted Valves Continued on next page Model/Size: Relief Valves Function Max. Pressure Max. Flow

44

UPF1S-12 – Code 61UPF1V-12 – Code 6211/2” Flange -Unloading Valve without Vent or Checkmm (inch)

P port (inlet)

For key removal

P port (outlet)

190,2(7.49)139,4

(5.49)80,0(3.15)

39,6(1.56)

40,0(1.57)

“V” series

80,0(3.15)

79,6(3.13)

“V” series

3,3(.13)3,7

(.14)“V” series

63,1(2.49)

71,1(2.80)

“V” series

Tank port (T port)∅ 38,1 (1.50) SAE Code 614-bolt flange(For UPF1V-12, Code 62 4-boltflange) connection thru

Accumulator pressure gage port or externalpilot port (models w/o check valve) - .5625-18 UNF-2B thd. for 3/8” O.D. tubing - G 1/4 BSP thd.

Pressure port (P port) - ∅ 38,1 (1.50) SAE Code 614-bolt flange(For UPF1V-12, Code 62 4-boltflange) connection thru

39,0(1.54)Ref.

For cap removal

“W” model (screw w/locknutmax. extension)

108,7(4.28)

152,2(5.99)

171,7(6.76)

155,7(6.13)

128,7(5.07)

“M” model (with micrometer adjust max. extension)

“K” model (key lock withmicrometer adjust max. extension)

External drain port - .5625-18 UNF-2B thd. for 3/8” O.D. tubing - G 1/4 BSP thd.

Code 62 flange

Code 62 flange

Page 45: Vickers Flange Valves Flange Mounted Pressure Controls · 2013-07-09 · 2 Flange Mounted Valves Continued on next page Model/Size: Relief Valves Function Max. Pressure Max. Flow

45

Tank port (T port) - ∅ 38,1 (1.50) SAE Code61 4-bolt flange thru

UPF1S-C*-12 Code 61UPF1V-CL-12 Code 6211/2” Flange -Unloading Valve without Vent with Checkmm (inch)

For key removal

P port (inlet)

For cap removal

P port (outlet)

171,7(6.76)

155,7(6.13)

128,7(5.07)

“M” model (withmicrometer adjust max. extension)

“K” model (key lock withmicrometer adjust max.extension)

190,2(7.49)139,4

(5.49)80,0(3.15)

3,3(.13)

155,8(6.13)39,6

(1.56)

79,6(3.13)

225,6(8.88)

152,2(5.99)

108,7(4.29)

39,0(1.54)Ref.

“W” model (screw w/locknutmax. extension)

132,5(5.22)

Pressure port (P port) - ∅ 38,1 (1.50) SAE Code 614-bolt flange connection

132,5(5.22)

97,0(3.82)

48,5(1.91)

63,1(2.49)

152,8(6.02)

78,5(3.09)

80,8(3.18)

Accumulator pressure gage port or external pilot port (models w/o check valve) - .5625-18 UNF-2B thd. for 3/8” O.D. tubing - G 1/4 BSP thd.

External drain port - .5625-18 UNF-2B thd. for 3/8” O.D. tubing - G 1/4 BSP thd.

“CL” Model Code 61In-line Check

“CL” Model Code 62In-line Check

155,8(6.13)

79,6(3.13) 39,6

(1.56)

190,2(7.49)139,4

(5.49)80,0(3.15)

P port (inlet)

T port∅ 38,1 (1.50) SAECode 61 4-bolt flangeconnection

3,3(.13)

3,7(.14)

196,9(7.75) 190,2

(7.49)139,4(5.49)41,0

(1.61)

156,2(6.15)

80,0(3.15)

40,0(1.57)

P port (inlet)

T port∅ 38,1 (1.50) SAECode 62 4-bolt flangeconnection

“C” Model Code 61Right Angle Check

Page 46: Vickers Flange Valves Flange Mounted Pressure Controls · 2013-07-09 · 2 Flange Mounted Valves Continued on next page Model/Size: Relief Valves Function Max. Pressure Max. Flow

46

UPF2*- (**) - 06/08/10/12-**-20Unloading Valves - With Vent

Flange Sizes� 06 - 3/4 inch flange� 08 - 1 inch flange� 10 - 11/4 inch flange� 12 - 11/2 inch flange

��������� Excellent repeatability and stable

performance from cartridgedesign mainstage parts.

� Reduced installed costs andspace requirements.

� Easier installation and servicingof components.

� Pilot design minimizes responsetime and cracking flow whichallows for high pressure stabilitythus increasing system productivity.

��Direct mounting to pump flangereduces potential leak points forsuperior leak resistance.

������� )������� )�������

Maximum flow 100 l/min (26 USgpm) 300 l/min (80 USgpm) 600 l/min (160 USgpm) 600 l/min (160 USgpm)Maximum pressure: P port 275 bar (4000 psi) 275 bar (4000 psi) 275 bar (4000 psi) 275 bar (4000 psi)* T port 207 bar (3000 psi) 207 bar (3000 psi) 207 bar (3000 psi) 207 bar (3000 psi)

)�������)�������

* The CPF2V-12 (code 62 flange) has a max. P port pressure rating of 350 bar (5000 psi).

"�� ��� ������!���

Electrical response is defined as thetime from initiation of power to thesolenoid, to the initiation of pressurerise, with 1,5 liters (.4 USgpm) of oilunder compression:

����� �������#$�%�������������������

100 bar (1450 psi) for DG4V-3S valve207 bar (3000 psi) for DG4V-3 valve AC207 bar (3000 psi) for DG4V-3 valve DC

������� ����!���10/12 Sizes: Rate of pressure rise with2,5 liters (.7 USgpm) of oil undercompression = 2600 bar (37500 psi)/second. Maximum overshoot < 10%.

06 Size: Rate of pressure rise with 2,5 liters (.7 USgpm) of oil undercompression = 3450 bar (50000 psi)/second. Maximum overshoot < 8%.

08 Size: Rate of pressure rise with 2,5 liters (.7 USgpm) of oil undercompression = 2900 bar (42000 psi)/second. Maximum overshoot < 10%.

06 size –@100 l/min (26 USgpm) = DC - 200 ms

AC - 160 ms08 size –@300 l/min (80 USgpm) = DC - 210 ms

AC - 175 ms10/12 size -@300 l/min (80 USgpm) = DC - 180 ms

AC - 160 ms

General DescriptionThis Vickers UPF2S relief valve featuresflange mounting for increased designflexibility and reduced external piping.The valve is designed for directmounting on the SAE flange outlet portof a pump. Fewer leak points and SAEflange connections lead to installationswith superior leak resistance.0��� ����� ����� ��������� ������ ����� ����������������� �������������� �������$������ ��� � �������� ������������������������������������������������� ����������������������

������� ������ ��������������� ������������� ������ �� ����������������� ���������������������������������������������� ����� ���� ����������� ������������������ ������������������������������������ ��������������������������

����0��21�� ����� ���!���������� �� ����� ���� ������ ���� � ���������������� ������ ���������� ��������������������������UPF valves are of two-stage design witha fast-acting poppet type main stage for simple, long-lasting andeffective operation. The many available

control options make it possible tochoose the optimum valve model foreach application.In construction, an unloading valvecontains a compound relief valve with apoppet-type main stage, a check valveto prevent reverse flow from theaccumulator, and a pressure operatedplunger, which vents the relief valve atthe selected pressure.

Page 47: Vickers Flange Valves Flange Mounted Pressure Controls · 2013-07-09 · 2 Flange Mounted Valves Continued on next page Model/Size: Relief Valves Function Max. Pressure Max. Flow

47

UPF2* Model Series

3 4 6 9871 2

Model Code

1

2

Valve Function

U - Unloading valve

Mounting Type

PF - Pump flange mounting

Unit Type

2 - Single pressure with vent

Flange Type

S - SAE J518 4-bolt flange standard series code 61 (available all sizes)

V - SAE J518 4-bolt high pressure series code 62 (size 12 only)

Integral Check Valve*(0,3 bar (5 psi) cracking pressure only)

Blank - Without right angle checkC - With right angle check - Not

available with UPF2V-12CL - In-line check

Valve Size

06 - 3/4 inch08 - 1 inch10 - 1 1/4 inch12 - 1 1/2 inch

3

4

8

Pressure Adjustment Range

A - 9 - 70 bar (130 - 1000 psi)B - 9 - 125 bar (130 - 1800 psi)F - 9 - 245 bar (130 - 3600 psi)G - 9 - 275 bar (130 - 4000 psi)

350 bar (5000 psi) - (UPF2V-12models only)

Control Type

W - Screw adjust with locknutK - Micrometer adjust with keylockM - Micrometer adjust w/o keylock

Thread Type(remote control/vent connection)

Blank - SAE-6 O-ring boss port(.5625-18 UNF-2B thd.)

B - BSP-G 1/4 (1/4” BSPF)

Accumulator Sense Port

Blank - Internal sense portP - External sense port

(not available w/check models)

Pilot Drain

Blank - Internal drain1 - External drain

Vent Valve

3S - Standard performance3 - High performanceUses 22A type spool/spring; otherfeatures are optional. Refer to Vickersliterature # GB-C-2015B SolenoidOperated Directional Control Valvescatalog.

Manual Override Options

Solenoid Energization Identification

Electrical Options Flag

Spool Position MonitoringSwitch

Solenoid Type/ElectricalConnections

Indicator Lights

Coil Voltage Identification

Tank Rating Pressure

2 - 10 bar (145 psi) for spool positionindicator models.

5 - 100 bar (1450 psi) for standardperformance models, DG4V-3S, with AC or DC solenoids.

6 - 207 bar (3000 psi) for highperformance models, DG4V-3, withAC solenoids.

7 - 207 bar (3000 psi) for highperformance models, DG4V-3 withDC solenoids.

Design Number, 20 Series

Subject to change. Installationdimensions unaltered for designnumbers 20 to 29 inclusive.

7

11

9

14

12 13

5

15

16

14 15 16 17 18 19 20 215 10

6

10

11

12

13

17

18

19

20

21

* The integral check valve is not the same as the DCPFS right angle check valve.

Page 48: Vickers Flange Valves Flange Mounted Pressure Controls · 2013-07-09 · 2 Flange Mounted Valves Continued on next page Model/Size: Relief Valves Function Max. Pressure Max. Flow

48

Circuit Schematics

&�,���

&�-���

With externaldrain models only.

UPF2S-C*-06/08-*-20 with check valve and vent UPF2S-06/08-(P)-*-20 with vent andwithout check valve

–06 size 100 l/min (26 USgpm) max. flow–08 size 300 l/min (80 USgpm) external drain150 l/min (40 USgpm) internal drain max. flow

Inlet

External drain

External drain

With externaldrain models only.

Inlet

Outlet

%�&���

&�'���

UPF2S-C*-10/12-*-20 with check valve and vent UPF2S-10/12-(P)-*-20 with vent andwithout check valve

–10/-12 sizes 600 l/min (160 USgpm) max. flow

T

&�,���

&�-���

%�&���

&�'���

Accumulator pressureGage port

Outlet

Accumulator pressureGage port

With externaldrain models only.

Inlet

External drain

Outlet

TAccumulator pressureGage port

External drain

With externaldrain models only.

Inlet

Outlet

Accumulator pressureGage port

Page 49: Vickers Flange Valves Flange Mounted Pressure Controls · 2013-07-09 · 2 Flange Mounted Valves Continued on next page Model/Size: Relief Valves Function Max. Pressure Max. Flow

49

Pressure Curves

Unload vs Recharge ∆ P Pressure @100 l/min (26 USgpm) with integral check valve as supplied.Internal DrainExternal Drain

Vented ∆ P P to T Internal DrainExternal Drain

UPF2S-06

∆ P P to P With 0,3 bar (5 psi) Check Valve

0

6,8

13,8

20,6

27,5

34,5

100

200

300

400

500

34,5 70 103 138 172 207 241 276Unload Pressure - bar

Unload Pressure - psi500 1000 1500 2000 2500 3000 3500 4000

Pre

ssur

e D

rop

- ba

r

Pre

ssur

e D

rop

- ps

i

Flow - l/min

Flow - USgpm

0

5.3 10.6 15.9 21.1 26.4

20 40 60 80 100

1

2

3

4

5

14.5

29

43.5

58

72.5

Pre

ssur

e D

rop

- ba

r

Pre

ssur

e D

rop

- ps

i

Flow - l/min

Flow - USgpm

0

5.3 10.6 15.9 21.1 26.4

20 40 60 80 100

1

2

3

4

5

14.5

29

43.5

58

72.5

Unload vs Recharge ∆ P Pressure with integral checkvalve as supplied.Internal Drain @150 l/min (40 USgpm)External Drain @300 l/min (80 USgpm)

Vented ∆ P P to T Internal DrainExternal Drain

UPF2S-08

∆ P P to P With 0,3 bar (5 psi) Check Valve

0

6,8

13,8

20,6

27,5

34,5

100

200

300

400

500

34,5 70 103 138 172 207 241 276Unload Pressure - bar

Unload Pressure - psi500 1000 1500 2000 2500 3000 3500 4000

Pre

ssur

e D

rop

- ba

r

Pre

ssur

e D

rop

- ps

i

Flow - l/min

Flow - USgpm

0

13.2 26.4 39.6 52.8 66

50 100 150 200 250

2

4

6

8

1079.3

300

29

58

87

116

145

0

Flow l/min50 100 150 200 250 300

Pre

ssur

e D

rop

bar 4

3

2

1

5

58

44

29

15

73

Pre

ssur

e D

rop

psi

13.2 26.4 39.6 52.8 66 79.3Flow USgpm

Rec

harg

e P

ress

ure

-

bar

∆ P

Rec

harg

e P

ress

ure

-

psi

∆ P

Rec

harg

e P

ress

ure

-

bar

∆ P

Rec

harg

e P

ress

ure

-

psi

∆ P

“C” right anglecheck

“CL” in-linecheck

“C” right anglecheck

“CL” in-linecheck

Page 50: Vickers Flange Valves Flange Mounted Pressure Controls · 2013-07-09 · 2 Flange Mounted Valves Continued on next page Model/Size: Relief Valves Function Max. Pressure Max. Flow

50

Vented ∆ P P to T Internal Drain @600 l/min (160 USgpm)External Drain @600 l/min (160 USgpm)

UPF2S-10

∆ P P to P With 0,34 bar (5 psi) Check Valve

0

6,8

13,8

20,6

27,5

34,5

100

200

300

400

500

34,5 70 103 138 172 207 241 276Unload Pressure - bar

Unload Pressure - psi500 1000 1500 2000 2500 3000 3500 4000

Pre

ssur

e D

rop

- ba

r

Pre

ssur

e D

rop

- ps

i

Flow - l/min

Flow - USgpm

0 100 200 300 400 500

26.4 52.8 79.3 105.6 132

5

10

15

20

72.5

145

218

290

Pre

ssur

e D

rop

- ba

r

UPF2S(V)-12Unload vs Recharge ∆ P Pressure with integral checkvalve as supplied.Internal Drain @600 l/min (160 USgpm)External Drain @600 l/min (160 USgpm)

41,4 600

600

158.4

Pre

ssur

e D

rop

- ps

i

Flow - l/min

Flow - USgpm

0 100 200 300 400 500

26.4 52.8 79.3 105.6 132

5

10

15

20

72.5

145

218

290

600

158.4

Vented ∆ P P to T Internal Drain @600 l/min (160 USgpm)External Drain @600 l/min (160 USgpm)

∆ P P to P With 0,34 bar (5 psi) Check Valve

0

6,8

13,8

20,6

27,5

34,5

100

200

300

400

500

34,5 70 103 138 172 207 241 276Unload Pressure - bar

Unload Pressure - psi500 1000 1500 2000 2500 3000 3500 4000

Pre

ssur

e D

rop

- ba

r

Pre

ssur

e D

rop

- ps

i

Flow - l/min

Flow - USgpm

0 100 200 300 400 500

26.4 52.8 79.3 105.6 132

5

10

15

20

72.5

145

218

290

Pre

ssur

e D

rop

- ba

r

Unload vs Recharge ∆ P Pressure with integral checkvalve as supplied.Internal Drain @600 l/min (160 USgpm)External Drain @600 l/min (160 USgpm)

41,4 600

600

158.4

Pre

ssur

e D

rop

- ps

i

Flow - l/min

Flow - USgpm

0 100 200 300 400 500

26.4 52.8 79.3 105.6 132

5

10

15

20

72.5

145

218

290

600

158.4

Rec

harg

e P

ress

ure

-

bar

∆ P

Rec

harg

e P

ress

ure

-

psi

∆ P

Rec

harg

e P

ress

ure

-

bar

∆ P

Rec

harg

e P

ress

ure

-

psi

∆ P

“C” right angle check

“CL” in-line check

“CL” in-line check

“C” right angle check

Page 51: Vickers Flange Valves Flange Mounted Pressure Controls · 2013-07-09 · 2 Flange Mounted Valves Continued on next page Model/Size: Relief Valves Function Max. Pressure Max. Flow

51

Installation Dimensions

UPF2S-06 3/4” Flange - Unloading with Vent without Check

mm (inch)

Pressure port T port-∅ 19,0 (.75) SAECode 61 4-bolt flangeconnection

Accumulator pressure gage port or externalpilot port models w/o check valve - .5625-18 UNF-2B thd. for 3/8” O.D. tubing - G 1/4 BSP thd.

140,3(5.53)

Pressure port P port - ∅ 19,0 (.75) SAE Code 61 4-bolt flangeconnection thru

For key removal

“W” model (screw w/locknutmax. extension)

For cap removal

“M” model (with micrometer adjust max. extension)

“K” model (key lock withmicrometer adjust max. extension)

171,7(6.76)

155,7(6.13)

128,7(5.07)

152,2(5.99)

108,7(4.29)

142,3(5.60)

62,2(2.45)

88,8(3.50)

39,6(1.56)

P port (inlet)

32,5(1.28)

63,4(2.50)

3,2(.12)

154,3(6.07)

13,6(.54)Ref.

62,7(2.47)

P port (outlet)

External drain port - .5625-18 UNF-2B thd. for 3/8” O.D. tubing - G 1/4 BSP thd.

Page 52: Vickers Flange Valves Flange Mounted Pressure Controls · 2013-07-09 · 2 Flange Mounted Valves Continued on next page Model/Size: Relief Valves Function Max. Pressure Max. Flow

52

UPF2S-C*-06 3/4” Flange - Unloading with Vent & Checkmm (inch)

Pressure port (P port) - ∅ 19,0 (.75) SAECode 61 4-bolt flange connection

Accumulator pressure gage port or external pilot port - .5625-18 UNF-2B thd. for 3/8” O.D. tubing - G 1/4 BSP thd.

“W” model (screw w/locknut max. extension)

140,3(5.50)

Tank port (T port) - ∅ 19,0 (.75) SAE Code61 4-bolt flangeconnection

For key removal

P port (inlet)

Gage port (accumulator) port .5625-18UNF-2B thd. for 3/8” tubing G 1/4 BSP thd.

For cap removal

“M” model (withmicrometer adjust max.extension)

“K” model (key lock withmicrometer adjust max.extension)

P port (outlet)

88,8(3.50)

39,6(1.56)

32,5(1.28)

65,0(2.58) 63,4

(2.50)

90,4(3.56)

166,5(6.55)

3,2(.12)

154,3(6.07)

123,4(4.86)

171,7(6.76)

155,7(6.13)

128,7(5.07)

152,2(5.99)

108,7(4.28)

142,3(5.60)

212,6(8.37)98,4

(3.88) 69,8(2.75)

13,6(.54)Ref.

82,6(3.25)

41,3(1.62)

62,7(2.47)

135,4(5.33)

62,2(2.45)

External drain port - .5625-18 UNF-2B thd. for 3/8” O.D. tubing - G 1/4 BSP thd.

“CL” ModelsIn-line Check

154,3(6.07)

3,2(.12)

140,3(5.53)

88,8(3.50)

39,6(1.56)

T port ∅ 19,0 (.75) SAE Code 61 4-bolt flangeconnection thru

P port (inlet)

114,2(4.50)

63,4(2.50)

32,5(1.28)

“C” ModelsRight Angle Check

Page 53: Vickers Flange Valves Flange Mounted Pressure Controls · 2013-07-09 · 2 Flange Mounted Valves Continued on next page Model/Size: Relief Valves Function Max. Pressure Max. Flow

53

UPF2S-081” Flange - Unloading with Vent without Checkmm (inch)

Tank port (T port) - ∅ 25,4 (1.00) SAECode 61 4-bolt flangeconnection

Accumulator pressure gage port or externalpilot port models w/o check valve - .5625-18 UNF-2B thd. for 3/8” O.D. tubing - G 1/4 BSP thd.

145,0(5.71)

Pressure port (P port) - ∅ 25,4(1.00) SAE Code 61 4-boltflange connection thru

For key removal

“W” model (screw w/locknutmax. extension)

For cap removal

“M” model (with micrometer adjust max. extension)

“K” model (key lock withmicrometer adjust max. extension)

171,7(6.76)

155,7(6.13)

128,7(5.07)

152,2(5.99)

108,7(4.29)

142,3(5.60)

62,2(2.45)

93,5(3.68)

47,9(1.89)

P port (inlet)

32,5(1.28)

63,4(2.50)

3,2(.12)

154,3(6.07)

13,6(.54)Ref.

62,7(2.47)

P port (outlet)

External drain port - .5625-18 UNF-2B thd. for 3/8” O.D. tubing - G 1/4 BSP thd.

Page 54: Vickers Flange Valves Flange Mounted Pressure Controls · 2013-07-09 · 2 Flange Mounted Valves Continued on next page Model/Size: Relief Valves Function Max. Pressure Max. Flow

54

UPF2S-C*-08 1” Flange - Unloading with Vent & Checkmm (inch)

Pressure port (P port) - ∅ 25,4(1.00) SAE Code 61 4-bolt flange connection

Accumulator pressure gage port or external pilot port - .5625-18 UNF-2B thd. for 3/8” O.D. tubing - G 1/4 BSP thd.

“W” model (screw w/locknut max. extension)

145,0(5.71)

Tank port (T port) - ∅ 25,4(1.00) SAE Code 61 4-boltflange connection

For key removal

P port (inlet)

Gage port (accumulator) port .5625-18UNF-2B thd. for 3/8” tubing G 1/4 BSP thd.

For cap removal

“M” model (withmicrometer adjustmax. extension)

“K” model (key lock withmicrometer adjust max.extension)

P port (outlet)

93,5(3.69)47,9

(1.89)

32,5(1.28)

65,0(2.58) 63,4

(2.50)

90,4(3.56)

166,5(6.55)

3,2(.12)

154,3(6.07)

123,4(4.86)

171,7(6.76)

155,7(6.13)

128,7(5.07)

152,2(5.99)

108,7(4.28)

142,3(5.60)

214,1(8.43)98,4

(3.88)69,8

(2.75)

18,6(.73)Ref.

82,6(3.25)

41,3(1.62)

62,7(2.47)

135,4(5.33)

62,2(2.45)

External drain port - .5625-18 UNF-2B thd. for 3/8” O.D. tubing - G 1/4 BSP thd.

“CL” ModelsIn-line Check

154,3(6.07)

3,2(.12)

T port ∅ 25,4 (1.00) SAE Code 61 4-bolt flangeconnection thru

P port (inlet)

63,4(2.50)

32,5(1.28)

123,4(4.86)

145,0(5.71)

93,5(3.69)

47,9(1.89)

“C” ModelsRight Angle Check

Page 55: Vickers Flange Valves Flange Mounted Pressure Controls · 2013-07-09 · 2 Flange Mounted Valves Continued on next page Model/Size: Relief Valves Function Max. Pressure Max. Flow

55

UPF2S-10 11/4” Flange - Unloading with Vent without Check

mm (inch)

P port ∅ 31,8 (1.25)SAE Code 61 4-boltflange connection thru

Accumulator pressure gage port or externalpilot port (models w/o check valve) - .5625-18 UNF-2B thd. for 3/8” O.D. tubing - G 1/4 BSP thd.

“W” model (screw w/locknutmax. extension)

196,9(7.36)

For cap removal

T port ∅ 31,8 (1.25) SAE Code 61 4-boltflange connection

P port (inlet)

75,8(2.98)

38,3(1.51)

67,0(2.64) 1,9

(.08)

136,1(5.36)

P port (outlet)

58,1(2.29)

108,7(4.28)

152,2(5.99)

For key removal

171,7(6.76)

155,7(6.13)

128,7(5.07)

“M” model (with micrometer adjust max. extension)

“K” model (key lock withmicrometer adjust max. extension)

155,0(6.10)

167,0(6.57)

30,0(1.18)

External drain port - .5625-18 UNF-2B thd. for 3/8” O.D. tubing - G 1/4 BSP thd.

Page 56: Vickers Flange Valves Flange Mounted Pressure Controls · 2013-07-09 · 2 Flange Mounted Valves Continued on next page Model/Size: Relief Valves Function Max. Pressure Max. Flow

56

UPF2S-C*-10 11/4” Flange - Unloading with Vent & Checkmm (inch)

T port ∅ 31,8(1.25) SAE Code 61 4-boltflange connection

P port (inlet)

For key removal

P port ∅ 31,8 (1.25) SAE Code 61 4-bolt flange connection

Accumulator pressure gage port or external pilot port - .5625-18 UNF-2B thd. for 3/8” O.D. tubing - G 1/4 BSP thd.

196,9(7.36)

For cap removal

“M” model (withmicrometer adjust max.extension)

“K” model (key lockwith micrometeradjust max.extension)

P port (outlet)

Gage port (accumulator).5625-18 UNF-2B thd. for 3/8” tubing G 1/4 BSP thd.

“W” model (screw w/locknutmax. extension)

75,8(2.98) 38,3

(1.51)

67,0(2.64)

1,9(.08)

136,1(5.36)

58,1(2.29)

108,7(4.28)

152,2(5.99)

171,7(6.76)

155,7(6.13)

128,7(5.07)

155,0(6.10)

167,0(6.57)

30,0(1.18)

152,0(5.98)

48,5(1.91)

152,9(6.02)

97,0(3.82)

261,8(10.31)

77,8(3.06)

111,9(4.41)

221,7(8.73)

132,5(5.22)

76,9(3.03)

External drain port - .5625-18 UNF-2B thd. for 3/8” O.D. tubing - G 1/4 BSP thd.

“CL” ModelsIn-line Check

“C” ModelsRight Angle Check

167,0(6.57)

1,9(.08)

196,9(7.36)136,1

(5.36)67,0(2.64)

145,8(5.74)

75,8(2.98)

38,3(1.51)

T port ∅ 31,8(1.25) SAE Code 61 4-boltflange connection

P port (inlet)

Page 57: Vickers Flange Valves Flange Mounted Pressure Controls · 2013-07-09 · 2 Flange Mounted Valves Continued on next page Model/Size: Relief Valves Function Max. Pressure Max. Flow

57

UPF2S-12 – Code 61UPF2V-12 – Code 6211/2” Flange - Unloading with Vent without Checkmm (inch)

P port (inlet)

For key removal

T port ∅ 38,1 (1.50)SAE Code 61 4-boltflange. (For UPF2V-12,Code 62 4-bolt flange) connection

Pressure port P port - ∅ 38,1(1.50) SAE Code 61 4-bolt flange(For UPF2V-12, Code 62 4-boltflange) P port connection thru

Accumulator pressure gage port or externalpilot port - .5625-18 UNF-2B thd. for 3/8” O.D. tubing - G 1/4 BSP thd.

P port (outlet)

80,0(3.15)

79,6(3.13)

“V” series 40,0

(1.57)

“V” series

39,6(1.56)

63,1(2.49)

71,1(2.80)

“V” series

39,0(1.54)Ref.

“M” model (with micrometer adjust max. extension)

“K” model (key lock withmicrometer adjust max. extension)

190,2(7.49)139,4

(5.49)80,0(3.15)

168,7(6.64)

3,3(.13)3,7

(.14)“V” series

171,7(6.76)

155,7(6.13)

128,7(5.07)

156,7(6.17) For cap

removal

“W” model (screw w/locknutmax. extension)

108,7(4.28)

152,2(5.99)

External drain port - .5625-18 UNF-2B thd. for 3/8” O.D. tubing - G 1/4 BSP thd.

Code 62 flange

Code 62 flange

Page 58: Vickers Flange Valves Flange Mounted Pressure Controls · 2013-07-09 · 2 Flange Mounted Valves Continued on next page Model/Size: Relief Valves Function Max. Pressure Max. Flow

58

UPF2S-C*-12 Code 61UPF2V-CL-12 Code 6211/2” Flange - Unloading with Vent & Checkmm (inch)

For key removal

P port (inlet)

Pressure Port (P port) ∅ 38,1 (1.50) SAE Code61 4-bolt flange connection

Accumulator pressure gage port or external pilot port - .5625-18 UNF-2B thd. for 3/8” O.D. tubing - G 1/4 BSP thd.

“M” model (withmicrometer adjustmax. extension)

“K” model (key lock withmicrometer adjust max.extension)

190,2(7.49)

For cap removal

T port∅ 38,1 (1.50) SAECode 61 4-bolt flangeconnection

P port (outlet)

“W” model (screww/locknut max.extension)

79,6(3.13)

39,6(1.56)

63,1(2.49)

39,0(1.54)Ref.

139,4(5.49)80,0

(3.15)

168,7(6.64)

3,3(.13)

171,7(6.76)

155,7(6.13)

128,7(5.07)

156,7(6.17)

108,7(4.28)

152,2(5.99)

80,8(3.18)

225,6(8.88)

132,5(5.22)

155,8(6.13)

97,0(3.82)

48,5(1.91)

152,8(6.02)

261,1(10.28)111,9

(4.41)78,5

(3.09)

Gage port (accumulator) port .5625-18 UNF-2B thd. for 3/8” tubing G 1/4 BSP thd.

External drain port - .5625-18 UNF-2B thd. for 3/8” O.D. tubing - G 1/4 BSP thd.

“CL” Model Code 61In-line Check

“C” Model Code 61Right Angle Check

“CL” Model Code 62In-line Check

155,8(6.13)

79,6(3.13) 39,6

(1.56)

190,2(7.49)139,4

(5.49)80,0(3.15)

168,7(6.64)

P port (inlet)

T port∅ 38,1 (1.50) SAECode 61 4-bolt flangeconnection

3,3(.13)

168,7(6.64)

3,7(.14)

196,9(7.75) 190,2

(7.49)139,4(5.49)41,0

(1.61)

156,2(6.15)

80,0(3.15)

40,0(1.57)

P port (inlet)

T port∅ 38,1 (1.50) SAECode 62 4-bolt flangeconnection

Page 59: Vickers Flange Valves Flange Mounted Pressure Controls · 2013-07-09 · 2 Flange Mounted Valves Continued on next page Model/Size: Relief Valves Function Max. Pressure Max. Flow

59

DCPFS-08/10/12-**-20Right Angle Check Valves

Flange Sizes� 08 - 1 inch flange� 10 - 11/4 inch flange� 12 - 11/2 inch flange (Not available with

Code 62 flanges.)

��������

� Fast opening and closing and stableperformance.

� 3����������������� ��������

�������������������������

�����������

� ������ �� ��� �������������

����������

� 1��������� ������ ����������1#

�� ����������� ����������������

������� +������� +�������

Maximum flow 114 l/min (30 USgpm) 227 l/min (60 USgpm) 378 l/min (100 USgpm)

Maximum pressure 275 bar (4000 psi) 275 bar (4000 psi) 275 bar (4000 psi)

+�������

General Description

This Vickers DCPFS check valve isflange mounted to increase designflexibility and reduce external piping.Fewer leak points and SAE flangeconnections lead to installations withsuperior leak resistance.

The DCPFS check valve is designed fordirect mounting on a pump flange, ormay be stacked with the CPF seriesrelief valves to provide a pumpunloading function. The DCPF is notintended to be used with the UPFSunloading valve.

Poppet design lifts easily to permit flowand reseats quickly to form a leakproofcheck to block flow in the oppositedirection. The DCPFS check valves canbe mounted in any position.

The DCPFS check valve has excellentoperating characteristics with sizes thatmake it possible to choose the optimummodel for each application.

3 4 5 761 2

Right Angle CheckModel Code

1

2

Special Seals

F3 - For mineral oil & fire resistant fluids.(Omit if not required)

Valve Function

DC - Check valve

Mounting Type

PF - Pump flange mounting

3

7

4

5

6Flange Type

S - SAE J518 4-bolt flange standard,series code 61

Valve Size

08 - 1” flange10 - 1 1/4” flange12 - 1 1/2” flange

Spring Cracking Pressure

5 - 0,3 bar (5 psi)50 - 3,4 bar (50 psi)75 - 5,2 bar (75 psi)

Design Number, 20 Series

Subject to change. Installationdimensions unaltered for designnumbers 20 to 29 inclusive.

Page 60: Vickers Flange Valves Flange Mounted Pressure Controls · 2013-07-09 · 2 Flange Mounted Valves Continued on next page Model/Size: Relief Valves Function Max. Pressure Max. Flow

60

DICPFS-06/08/10/12-**-10In-Line Check Valves

Flange Sizes� 06 - 3/4 inch flange� 08 - 1 inch flange� 10 - 11/4 inch flange� 12 - 11/2 inch flange (Available with

Code 62 high pressure.)

������� +,������� +,�������

Maximum flow 120 l/min (32 USgpm) 300 l/min (80 USgpm) 600 l/min (160 USgpm) 750 l/min (200 USgpm)

Maximum pressure 350 bar (5000 psi) 350 bar (5000 psi) 280 bar (4000 psi) 207 bar (3000 psi)

* DICPFV-12 Code 62 high pressure flange is rated at 750 l/min (200 USgpm) at 350 bar (5000 psi)

+,������� +,�������*

Features

� Direct mounting to SAE flange.

� Compact, robust design.

� Low pressure drop design.

� Wide flow/pressure range.

General Description

Vickers flange mounted in-line checkvalves can be used with the existing lineof flange mounted pressure controls.The DICPF in-line check valves come infour sizes, 06 (.75”), 08 (1”), 10 (1.25”)and 12 (1.50”).

These are direct, flange mounted, in-linecheck valves with SAE 4-bolt mounting.They may be mounted directly on anSAE pump flange, actuator, manifold ormay be stacked with a Vickers CPFrelief valve to provide a pump unloadingfunction.

This mounting style results in a muchsmaller space requirement andeliminates plumbing and potential leakpoints that result from installation ofconventional line mounted check valves.

These check valves are not to be usedwith the UPF flange mounted unloadingrelief valves.

6

3 4 5 61 2

In-Line Check Model Code

1

2

Valve Function

DIC – Direct inline check

Mounting Type

PF – Pump flange mounting

Cracking Pressure

05 – 0,3 bar (5 psi)25 – 1,7 bar (25 psi)

Design Number

3

4

5Flange Type

S – SAE J518 4-bolt flange, std.pressure series, code 61

V – SAE J518 4-bolt flange, highpressure series, code 62 (1.50 in. models only)

Valve Size

06 – 0.75 in. flange, SAE-1208 – 1.00 in. flange, SAE-1610 – 1.25 in. flange, SAE-2012 – 1.50 in. flange, SAE-24

Page 61: Vickers Flange Valves Flange Mounted Pressure Controls · 2013-07-09 · 2 Flange Mounted Valves Continued on next page Model/Size: Relief Valves Function Max. Pressure Max. Flow

61

Pressure Drop Data

+������� +�������'��

���������4���

����������!� -�����.&�/���01�!��2 �� 3����!�������4���

2&&

%-.

%.&

%2.

%&&

-.

.&

2.

&

& %& 2& 5& .& ,& -&6&01���

����������!� -�����.&�/���01�!��2����&.(�/���01��!��2� �� 3����!�������4���

���������4���

2&&

%-.

%.&

%2.

%&&

-.

.&

2.

&

& . %& %. 2& 2. 6&

�� � ��� � �

%6�7

%2�%

%&�6

7�,

,�'

.�2

6�5

%�-

&

%6�7

%2�%

%&�6

7�,

,�'

.�2

6�5

%�-

&

����

�"�� & 67 -, %.% %7' 22- 2,.%%501���

����

�"�� & %' 67 .- -, '. %%5

4���18%&

7&

6&6

'&

65%

%&&

6-7

4���18%2&�6�� ��9.���:

6�5�� ��9.&���:

Right Angle Check Valves

In-Line Check Valves

Flow - USgpm Flow - USgpm

Flow - USgpm

0 4 8 12 16 20 24 28 32

Pre

ssur

e D

rop

- ba

r

Pre

ssur

e D

rop

- ps

i

Flow - l/min

Pre

ssur

e D

rop

- ba

r

Pre

ssur

e D

rop

- ps

iFlow - l/min

Pre

ssur

e D

rop

- ba

r

Pre

ssur

e D

rop

- ps

i

Flow - l/min

Flow - USgpm

Pre

ssur

e D

rop

- ba

r

Pre

ssur

e D

rop

- ps

i

Flow - l/min

0

1

2

3

4

5

0 20 40 60 80 100 120

70

60

50

40

30

20

10

0

-06 size0.75 in.

0

1

2

3

4

570

60

50

40

30

20

10

00 50 100 150 200 250 300

0 10 20 30 40 50 60 70 80

-08 size1.00 in.

0

2

4

6

8

10

0 20 40 60 80 100 120 140 160

140

120

100

80

60

40

20

00 100 200 300 400 500 600

-10 size1.25 in.

0

1

2

3

4

5

60 40 80 120 160 200

70

60

50

40

30

20

10

0

80-12 size1.50 in.

0 150 300 450 600 750

Page 62: Vickers Flange Valves Flange Mounted Pressure Controls · 2013-07-09 · 2 Flange Mounted Valves Continued on next page Model/Size: Relief Valves Function Max. Pressure Max. Flow

62

Installation Dimensions

DCPFS - 08/10/12Right Angle Check Valve

mm (inch)

Outlet port

Inlet port

#

* �

4

E

F

GH

JK

M

NP

Q

R

S

Model

Dimensions

DCPFS–08

DCPFS–10

DCPFS–12

A B C D E F G H J K � N P 5 R S

102,9(4.05)

91,9(3.62)

59,9(2.36)

64,8(2.55)

57,2(2.25)

28,4(1.12)

135,1(5.32)

106,7(4.20)

52,3(2.06)

26,2(1.03)

25,4(1.00)Dia.

26,2(1.03)

13,2(.52)

10,3(.406)Dia.

4–bolt flange

85,3(3.36)

41,1(1.62)

146,0(5.75)

133,6(5.26)

76,2(3.00)

80,8(3.18)

68,3(2.69)

34,0(1.34)

152,9(6.02)

118,6(4.67)

58,7(2.31)

29,5(1.16)

31,7(1.25)Dia.

30,2(1.19)

15,0(.59)

11,9(.469)Dia.

99,8(3.93)

48,5(1.91)

SAE flange

146,0(5.75)

133,6(5.26)

76,2(3.00)

68,3(2.69)

34,0(1.34)

152,9(6.02)

118,6(4.67)

69,8(2.75)

35,1(1.38)

38,1(1.50)Dia.

35,8(1.41)

17,8(.70)

13,5(.531)Dia.

99,8(3.93)

48,5(1.91)

SAE code 61 4 bolt flange connection, 2 places

4–bolt flange connectionthru (4 places)

80,8(3.18)

“K” - thru(4 places)

“A”“C”

“E”

“D”

“J”“H”

“F”

“G”

Free Flow Direction

Check Seat

Check Ball

Port “A” Inlet

O-ring Seal“B”

Port “B” Outlet

FlangeSize (inch)

Model Code “A” “B” “C” “D” “E” “F” “G” “H” “J” “K”

3/4” S - 06

Standard Pressure Series (Code 61) mm (inch)

19,1 (.75) 50,8 (2.0) 52,0 (2.05) 65,0 (2.56) 66,5 (2.61) 47,6 (1.88) 23,8 (.906) 22,2 (.875) 11,1 (.437) 10,4 (.407)

S - 08 25,4 (1.00) 60,0 (2.36) 58,5 (2.30) 70,0 (2.76) 71,5 (2.81) 52,4 (2.06) 26,2 (1.03) 26,2 (1.03) 13,1 (.516) 10,4 (.407)1”

S - 10 31,6 (1.25) 70,0 (2.76) 73,0 (2.88) 79,0 (3.11) 80,5 (3.16) 58,7 (2.31) 29,4 (1.16) 30,2 (1.19) 15,1 (.594) 12,0 (.470)1 1/4”

S - 12 38,1 (1.50) 76,2 (3.00) 82,5 (3.25) 93,5 (3.68) 95,0 (3.74) 69,9 (2.75) 34,9 (1.38) 35,7 (1.41) 17,9 (.703) 13,5 (.532)1 1/2”

Flange Size (inch)

Model Code “A” “B” “C” “D” “E” “F” “G” “H” “J” “K”

High Pressure Series (Code 62) mm (inch)

V - 12 38,1 (1.50) 76,2 (3.00) 95,0 (3.74) 112,5 (4.43) 114,0 (4.48) 79,4 (3.13) 39,7 (1.56) 35,7 (1.44) 18,3 (.720) 16,7 (.657)1 1/2”

DICPF* -06/ 08/10/12In-Line Check Valve

Free Flow Direction

Page 63: Vickers Flange Valves Flange Mounted Pressure Controls · 2013-07-09 · 2 Flange Mounted Valves Continued on next page Model/Size: Relief Valves Function Max. Pressure Max. Flow

(������6"���������������*�9/ !�������� ������������2&-�� ��96&&&���:

4 �

*

;

< = >

?�@�1�������� �?#@����� ��1# ��� ��

A�/ !��4 �

���� 6���4/��6�

�6"�������-�%-����

� � + " � 7 � 8 9 :

�>%878%,18%&

�>%8%&82&18%&

�>%8%282518%&

�� ��������������� ����������� � ���������

,7676&

,7676%

,76762

%�6%2.8%29%�&@����:

%�,2.8%29%%"5@�����:

%�7-.8%29%%"2@�����:

.7�-92�6%:

-6�292�77:

72�,96�2.:

6"7�%,

-"%,�%5

%"2�%6

-&92�-.:

-'�296�%2:

'6�-96�,':

2,�29%�&6:

2'�.9%�%,:

6.�%9%�67:

.2�592�&,:

.7�-92�6%:

,'�'92�-.:

%6�29&�.2:

%.9&�.':

%-�79&�-&:

2,�29%�&6:

6&�29%�%':

6.�79%�5%:

2.�59%�&&:

6%�79%�2.:

67�%9%�.&:

%,�79&�,,:

2%�69&�75:

%7�.9&�-6:

6.�%9%�67:

67�%9%�.&:

5%�%9%�,2:

�>%8,8%218%& ,7672'%�&,2.8%296"5@����:

.2�692�&,:

6"7�%,,.�&92�.,:

26�,9�'6:

5-�79%�77:

%&�'9&�56:

22�29�7-.:

%'�%9�-.&:

%6�.9&�.6:

6%�79%�2.:

* For additional information on SAE 4-bolt flanges see Vickers Catalog 700 or GB-C-2005A

���9�����:

63

Application Data

Service Information3���������������������������� ����

����� ������ �����(

���%1�&,"&7"%&"%2 B�6---�1

���21�&,"&7"%&"%2 B�6--7�1

���6"51�&,"&7"%&"%2 B�6--'�1

0��%1�&,"&7"%&"%2 B�6-,7�1

0��21�&,"&7"%&"%2 B�6-,'�1

4���1�&,"&7"%&"%2 B�656.�1

����� ������������� ���(

4<5C8691:8DD8,& B�677,�1

;���-��

���%1�8 &, .�5���� 9%2����:

���21�8 &, ,�'���� 9%.�.����:

���6"518 &, '�2���� 92&�.����:

���%1�8 &7 .�.���� 9%2�6����:

���21�8 &7 -�%���� 9%.�7����:

���6"518 &7 '�5���� 92&�7����:

���%1�8 %& 7�2���� 9%7����:

���21�8 %& '�.���� 92%����:

���6"518 %& %2���� 92,�.����:

���%D�8 %2 '�,���� 92%�6����:

���2D�8 %2 %%���� 925�6����:

���6"5D8 %2 %6�.����92'�7����:

0��%1�&,��"����� 7�'���� 9%'�7����:

0��%1�&,��"������� .�6���� 9%%�7����:

0��21�&,��"����� %&�,����926�.����:

0��21�&,��"������� -���� 9%.�.����:

0��%1�&7��"����� 7�'���� 9%'�7����:

0��%1�&7��"������� .�6���� 9%%�7����:

0��21�&7��"����� %&�,����926�.����:

0��21�&7��"������� -���� 9%.�.����:

0��%1�%&��"����� %5�.��� 962����:0��%1�%&��"������� 7�2���� 9%7����:0��21�%&��"����� %.�'����96.����:0��21�%&��"������� '�.���� 92%����:0��%D�%2��"����� %,���� 96.�6����:0��%D�%2��"������� '�,���� 92%�6����:0��2D�%2��"����� %-�6����967�6����:0��2D�%2��"������� %%���� 925�6����:4���1�8�&7 6�,���� 97����:4���1�8�%& .�'���� 9%6����:4���1�8�%2 .�'���� 9%6����:4B���1�8�&, &�7��� 9%�.'����:4B���1�8�7 %�2��� 92�56����:4B���1�8�%& %�'��� 95�26����:4B���1�8�%2 2�,��� 9.�.7����:

<���������� ����E������������ ������� ������������

�������������������� ���� ��������

�������������������������

���� �������������$��������

Page 64: Vickers Flange Valves Flange Mounted Pressure Controls · 2013-07-09 · 2 Flange Mounted Valves Continued on next page Model/Size: Relief Valves Function Max. Pressure Max. Flow

64

Fluid Cleanliness

Hydraulic Fluid Information ���� ������� ���������������

������������� ������� ����������

���������� � 3����!/�� �����1��F

?C������<������1�����

��� �� ����������@� � � ��������

�������� ��C�������������������

��� ����C�������B������� ���

3�������� ���������� ��� �����

��������������������������������

������� �������������C�����

����� ���.,%�

3�������������� ������������������

��������������������������������

��� �����������������������������

�����������������(

B���������������� �������������

�� ���� �� �����������

��������������� ����������������

�� ������������ �����

������������ ������������������

���������������������� �����!�����

���� �������� ���������������

��� ��������������1���C�����

����� ���.,%������! ���� ���

SYSTEM PRESSURE LEVEL

PRODUCT 69 bar (1000 psi) 138 bar (2000 psi) 207+ bar (3000+ psi)

Vane Pumps – FIxed 20/18/15 19/17/14 18/16/13

Vane Pumps – Variable 18/16/14 17/15/13

Piston Pumps – Fixed 19/17/15 18/16/14 17/15/13

Piston Pumps – Variable 18/16/14 17/15/13 16/14/12

Directional Valves 20/18/15 20/18/15 19/17/14

Pressure/Flow Control Valves 19/17/14 19/17/14 19/17/14

Servo Valves 16/14/11 16/14/11 16/13/10

Proportional Valves 16/14/12 16/14/12 15/13/11

Cylinders 20/18/15 20/18/15 20/18/15

Vane Motors 20/18/15 19/17/14 18/16/13

Axial Piston Motors 19/17/14 18/16/13 17/15/12

Radial Piston Motors 20/18/14 19/17/13 18/16/13