V.I. InspectionsPage 1 of 10
21:39 January 22, 2018
#1 1245 NW 126th St, Seattle. #2 Water seepage at gutter/fascia connection over
garage.
#3 Minor chipping in garage door veneer. #4 Some of the exterior lights are nonfunctional.
#5 Rot in small areas of gutter system. #6 Minor rot present in S fence system.
Palm-Tech Picture Album, Copyright © 1998-2018 PDmB, Inc.
V.I. InspectionsPage 2 of 10
21:39 January 22, 2018
#7 Minor water seepage at gutter/fascia on E side of S
chimney.
#8 Cracks in walkway system with displacement present.
#9 Minor displacement in sections of concrete walkway. #10 Bench design is too low to today's standards.
#11 Minor rot in decking piece at S end of S deck. #12 Minor rot in trim of S deck bench system.
Palm-Tech Picture Album, Copyright © 1998-2018 PDmB, Inc.
V.I. InspectionsPage 3 of 10
21:39 January 22, 2018
#13 Sections of mortar missing from S brick column. #14 Broken brick in lower SW brick retaining wall.
#15 Sections of mortar missing in lower W brick patio. #16 NW sump pump powered by switched outlet, circuit
needs to stay on for pump to work.
#17 Sump pump next to NW side of house needs to stay
on for correct drainage.
#18 Sump pump in backyard collects driveway and
downspout water.
Palm-Tech Picture Album, Copyright © 1998-2018 PDmB, Inc.
V.I. InspectionsPage 4 of 10
21:39 January 22, 2018
#19 Sump pump in backyard collects driveway and
downspout water.
#20 Steep slope on W side of house.
#21 Bench design is too low to today's standards. #22 Some exterior lights are nonfunctioning.
#23 Minor rot along lower edges of some roof shake
material.
#24 Minor cupping in cedar shake roof.
Palm-Tech Picture Album, Copyright © 1998-2018 PDmB, Inc.
V.I. InspectionsPage 5 of 10
21:39 January 22, 2018
#25 A couple of shake pieces missing. #26 Sections of ridge caps moderately worn.
#27 No counter flashing caps installed on lead flashing
boots.
#28 S basement bathroom/laundry room and dryer vent
roof caps are moderately rusty.
#29 Standing water in S gutter. #30 S chimney.
Palm-Tech Picture Album, Copyright © 1998-2018 PDmB, Inc.
V.I. InspectionsPage 6 of 10
21:39 January 22, 2018
#31 Repaired crack in crown. Recommend rain cap be
installed over flue.
#32 Markings on W roof indicates past pressure washing.
#33 Wooden gutters worn in sections. #34 Metal patch in NW roof section.
#35 Middle chimney. #36 Minor crack in crown material.
Palm-Tech Picture Album, Copyright © 1998-2018 PDmB, Inc.
V.I. InspectionsPage 7 of 10
21:39 January 22, 2018
#37 Furnace flue cap flashing moderately rusty. #38 Recommend installing rain caps.
#39 Gap between crown and chimney should be sealed. #40 Sections of ridge cap material moderately worn.
#41 Garage attic. #42 Bathroom fan ducts and dryer duct should be
insulated against condensation build up.
Palm-Tech Picture Album, Copyright © 1998-2018 PDmB, Inc.
V.I. InspectionsPage 8 of 10
21:39 January 22, 2018
#43 Staining in middle rafter indicates past water
leakage, dry at time of inspection.
#44 Wiring installed too close to attic access in master
bedroom closet.
#45 Sections of carpet well worn. #46 Recommend cleaning heat ducts.
#47 Upper NW tile loose in master shower. #48 Minor staining in master bedroom ceiling indicates
past leakage, dry at time of inspection.
Palm-Tech Picture Album, Copyright © 1998-2018 PDmB, Inc.
V.I. InspectionsPage 9 of 10
21:39 January 22, 2018
#49 Stair carpet well worn. #50 Carpet well worn in basement hallway. Staining
indicates past water event from laundry room.
#51 Cannot verify electrical bond from cold water to hot
water.
#52 Heat duct work should be cleaned.
#53 Tapes light switch in entryway and at family room
entry controls outlet for NW sump pump.
#54 Dried silt and drilled holes in family room heat duct
indicates past water intrusion into heat duct system.
Palm-Tech Picture Album, Copyright © 1998-2018 PDmB, Inc.
V.I. InspectionsPage 10 of 10
21:39 January 22, 2018
#55 No earthquake straps on hot water tanks. #56 Main floor furnace filter needs to be changed.
#57 Access hole to flue for N furnace needs to be sealed
against exhaust back draft.
#58 Live wiring in junction box in N furnace closet.
Palm-Tech Picture Album, Copyright © 1998-2018 PDmB, Inc.